Form No. 1 Solar Domestic Water Heater, Applied for Villas.

19/2/2012 v1
Solar Water Heater Scheme :
The size and performance of the solar system must be
t o r
llec calculated using actual design and installation conditions
r Co
South So
la taking into consideration all the affecting parameters
o including the collector slope angle and direction. Any
25
changes that are incorporated into the system during
construction shall be considered.

Average Daily Hot Water Consumption:

Average Daily Hot Water Consumption per Villa = No. of Toilets / Bathrooms x 50 L =

+ No. of WCs x 30 L =

+ No. of Kitchens x 80 L =

Note: for the hot water consumption details, refer to attached table. L / day / villa

Design Parameters and Requirements:


Design parameters and requirements shall be according to circular No. 183/2011 and International Best Practices, with emphasis
on the following:
0
1- Hot water storage tempe. = 60 C.
0
2- Average dry ambient temp. (Summer): 42 C.
0
3- Average dry ambient temp. (Winter): 14 C.
4- The minimum hot water storage tank capacity equal to seventy five percent (75%) of the total daily consumption of hot water.
5- Back-up electrical immersion heater to be provided.
6- The solar water heater system shall be installed, operated and maintained by a registered and licensed company by the
Department of Economic Development and approved by Dubai Municipality.
7- The solar water heater system shall be approved by Dubai Central Laboratory.

Undertaking:
I/we hereby commit to meet the full requirements of Circular No. 183/2011 issued by Dubai Municipality regarding Solar Water
Heaters. This commitment without exception applies to the design, installation and commissioning of the Solar Water Heaters.
The solar water heater system shall be installed, operated and maintained by a registered and licensed company by the
Department of Economic Development and approved by Dubai Municipality. The solar water heater system shall be approved by
Dubai Central Laboratory.
It is understood that failure to comply with the regulations may also result in a fine or other penalty.

Notes:
1- This sheet shall be attached to the roof plan of water supply drawings, and uploaded with sewerage drawings in the plumbing folder.
2- No separate electric water heater shall be used.
3- Incase more than one type of typical villas (with different Average Daily Hot Water Consumption) is available, then additional
sheet(s) for each type to be attached.

AL GURG CONSULTANTS