Do 147 S2017
Do 147 S2017
Do 147 S2017
L:>""~
''<' jl'~ .]A)!,?
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
OFFICE OF THE SECRETARY
MANILA
Il5 DEe201~
147 )
)
CONCRETE, CLAY, PLASTIC AND
FIBER PIPE (Item 706.14.2
Structured Wall Pipe - High Density
Polyethylene Pipe)
In order to ensure uniformity in the application/ adoption of the Pay Items of Work to be
used/ adopted by those who are involved in the preparation of the Design Plans and
Quantities, Program of Works (POW) and Approved Budget for the Contract (ABC) for
Infrastructure Projects Nationwide, and to provide material requirements to the
aforementioned expansion joints, the attached DPWH Standard Specifications for
Item 706.14.2 Structured Wall Pipe - High Density Polyethylene Pipe are hereby
prescribed, for the guidance and compliance of all concerned.
This Standard Specifications form part of the DPWH Standard Specifications for Highways,
Bridges and Airports, Volume II and now included in the Project and Contract Management
Application (PCMA).
. .r
~~---
MARK A. VILLAR
Secretary
14.1.2 MLL/RGT
Departrrent of Public Works and Highways
Office of the Secretary
111111111111111111111I11111I111111111
WIN7U01550
DPWH Standard Specification for
Item 706 - Concrete, Clay, Plastic and Fiber
Pipe
This pipe shall conform to the requirements of AASHTO M 86M (ASTM C 14M), Standard
Specification for Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe for the
specified internal diameters, wall thickness, length, straightness and strength classes.
This pipe shall conform to the requirements of AASHTO M 170M (ASTM C 76), Standard
Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe or
AASHTO M 242M (ASTM C 655), Standard Specification for Reinforced Concrete D-Load
Culvert, Storm Drain, and Sewer Pipe for specified internal diameters, wall thickness, length,
reinforcement and strength classes.
Precast reinforced concrete and sections shall conform to the requirements of the cited
specifications to the extent which they apply.
. f
This pipe intended to be used for underdrainage shall conform to the requirements of
AASHTOM 175M (ASTMC 444M), Standard Specificationfor Perforated Concrete Pipefor the
specified types, internal diameters and slot length and spacing.
The concrete drain tile with internal diameter from 100 mm to 900 mm that are intended to
be used for surface and subsurface drainage shall conform to the requirements of
AASHTOM 178M(ASTMC 412), Standard Specificationfor ConcreteDrainTile for the specified
internal diameter, wall thickness, length, shape, strength and absorption.
Clay drain and perforated clay drain tile shall conform to the requirements of
ASTM C 4, Standard Specification for Clay Drain Tile and Perforated Clay Drain Tile for the
specified sizes and strengths.
This non-reinforced concrete pipe for use in underdrains shall conform to the requirements of
AASHTO M 176M (ASTM C 654), Standard Specification for Porous Concrete Pipe for the
specified internal diameters, strength and porosity or rate of infiltration tests.
Department Order NO.l5:f:f:rSeries of 2017
DPWH Standard Specifications for Item 706, Concrete, Clay, Plastic and Fiber Pipe
ANNEX Page 2 of 4
This pipe shall conform to the requirements of AASHTO M 252, Standard Specification for
Corrugated Polyethylene Drainage Pipe.
Department Order No . .J.!B., Series of 2017
DPWH Standard Specifications for Item 706, Concrete, Clay, Plastic and Fiber Pipe
ANNEX Page 3 of 4
This pipe shall conform to the requirements of ASTM F 714, Standard Specification for
Polyethylene (PE) Plastic Pipe (DR-PR) Based on Outside Diameter and shall be based upon
the DIPS, outside diameter sizing system. The dimension ratio (DR) of pipe to be installed
shall also be either shown on the drawings or as directed by the Engineer.
Thermoplastic pipes and fittings with a structured wall and smooth inside surface, including
different jointing systems for gravity and low pressure applications, such as storm drain,
sewer,and sea outfall, with a large diameter of ONliD 250 to ON/ID 4000mm,inside diameter
based polyethylene (PE) pipe shall conform to the requirements of ASTM F 894, Standard
Specification for Polyethylene (PE) large Diameter Profile Wall Sewer and Drain Pipe.
706.15 Precast Reinforced Concrete Box Sections for Culverts, Storm Drains
and Sewers
These sections shall conform to the requirements of AASHTO M 259M, Standard Specification
for Precast Reinforced Concrete Box Section for Culverts, Storm Drains, and Sewers and
ASTM C 1433, Standard Specification for Precast Reinforced Concrete Monolithic Box Sections
for Culverts, Storm Drains, and Sewers.
This pipe shall conform to the requirements of AASHTO M 264 (ASTM D 2680), Standard
Specification for Acrylonitrile - Butadiene - Styrene (ABS) and Polyvinyl Chloride (PVC)
Composite Sewer Piping.
This pipe shall conform to the applicable requirements of AASHTO M 278, Standard
Specification for Class PS46 Polyvinyl Chloride (PVC) Pipe or AASHTO M 304, Standard
Specification for Polyvinyl Chloride (PVC) Profile Wall Drain Pipe and Fittings Based on
Controlled Inside Diameter, ASTM D 2729, Standard Specification for Polyvinyl Chloride (PVC)
Sewer Pipe and Fittings and ASTM F 679, Standard Specification for Polyvinyl Chloride (PVC)
large-Diameter Plastic Gravity Sewer Pipe and Fittings.
A. Pipes
1. Pipe sizes shall be as shown on the drawings, unless otherwise approved by the Engineer.
a.1. For sanitary uPVC pipes and fittings sizes 57 mm up to 160 mm shall conform to
AASHTO M 278 or AASHTO M 304 or ASTM D 2729.
a.2. For uPVC sizes 160 mm and up shall conform to ASTM F 679, Standard
Specification for Polyvinyl Chloride (PVC) large-Diameter Plastic Gravity Sewer
Pipe and Fittings.
B. Joints
1. All joints shall be elastomeric ring and should be machine installed fixed seal made of
Ethylene Propylene Diene Monomer (EPDM) rubber bonded with stiff polypropylene
ring unless approved otherwise by the Engineer.
2. Double sockets or slip on sockets may be used adjacent structures or special fittings.
3. Solvent welded joints may be used for buried fittings if assembled in the
manufacturer's workshop under the Engineer's supervision. Solvent shall be as per the
pipe manufacturer's recommendation.
4. Solvent or welded fittings may be used for exposed piping, if approved by the Engineer.
Solvent cemented joints shall be allowed provided that the designed strength can be
attained for at least 24 hours and shall be subjected to internal pressure of 0.17 MPa
using water as the test medium within one (1) hour. Examine the joint for leakage .
. f
References:
1. ASTM F894, Standard Specification for Polyethylene (PE) Large Diameter Profile WaR Sewer
and Drain Pipe.
2. ASTM F 679, Standard Specification for Polyvinyl Chloride (PVC) Large-Diameter Plastic Gravity
Sewer Pipe and fittings.
3. DENR Administrative Order No. 2000 - 02 January 06, 2000 (Chemical Control Order for
Asbestos.)
4. DIN 16961 - Thermoplastics Pipes and fittings with Profiled Wall and Smooth Pipe Inside.