0% found this document useful (0 votes)
49 views

Workout Example Design of Short Column (Circular) : Solution

This document provides an example of designing a short circular concrete column to resist an axial load of 5600 kN and a bending moment of 50 kN-m. It outlines the material properties and design assumptions. The column is designed to have a diameter of 650 mm and longitudinal and transverse reinforcement areas of 83.64 cm^2 and 116.24 cm^2 respectively to satisfy strength and serviceability requirements. An interaction diagram is presented showing the column's capacity to resist different combinations of axial load and bending moment.

Uploaded by

MrAlittle Finger
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views

Workout Example Design of Short Column (Circular) : Solution

This document provides an example of designing a short circular concrete column to resist an axial load of 5600 kN and a bending moment of 50 kN-m. It outlines the material properties and design assumptions. The column is designed to have a diameter of 650 mm and longitudinal and transverse reinforcement areas of 83.64 cm^2 and 116.24 cm^2 respectively to satisfy strength and serviceability requirements. An interaction diagram is presented showing the column's capacity to resist different combinations of axial load and bending moment.

Uploaded by

MrAlittle Finger
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Workout Example Design of Short Column (Circular)

Load on column Pu  5600kN

Moment M u  50kN m

Compressive strength of concrete f'c  25 MPa

Yeild strength of reinforcement fy  390  MPa

Material Assumption

Strength reduction factors confinement ϕ 

Maximum Compressive Strain in concrete ε u  0.003

Cover to transversal reinforcement CL  40mm

Diameter of tensile reinfocement D  20mm

Diameter of stirrup reinforcement Dv  10mm

Material Assumption

Solution
Column section Design

Assume ρg  0.03

Pu

0.85 ϕ 2
Ag  Ag  3136.788 cm

0.85 f'c 1  ρg  fy  ρg 
 Ag 
Diameter of column Dc  Ceil 50mm Dc  650  mm
 π 
2  4 
π Dc 2
Ag  Ag  3318.307 cm
4

Pu
 0.85 f'c Ag
0.85 ϕ 2
Ast  Ast  83.643 cm
0.85 f'c  fy

Ast
ρg  ρg  0.025
Ag
Ds  Dc  2   CL  Dv  
D
Ds  530  mm
 2

π ( D)
2  Ast 
As0  n s  ceil   10  37
4
 As0 
2 π Ds
Ast  n s As0  116.239  cm s   46.251 mm
ns  1

ORIGIN  1

Dc Ds
rc  rs 
2 2

360deg
i  1  n s αs   ( i  1)
i ns

d  rc  rs cos αs  d t  max( d )  589.045  mm


i  i 

Equivalent depth factor

β1  0.85 if f'c  27.6MPa β1  0.85 (ACI.10.2.7.3)

0.65 if f'c  55.2MPa

f'c  27.6MPa
0.85  0.05 otherwise
6.9MPa

Depth of the rectangular compression block

a = β1  c (ACI.10.2.7.1)

Maximum depth of the compression zone,

a
c( a) 
β1

i  1  n s
Area and centroid of segment

 rc  a 
α( a)  acos 
 rc 

2  rc sin( α( a) )
3
x c( a)  
3 α( a)  sin( α( a) )  cos( α( a) )

2
Ac( a)  rc  ( α( a)  sin( α( a) )  cos( α( a) ) )

ϕPn.max  ϕ 0.8 0.85f'  π r 2  A   f  0.85 f'  if ϕ = 0.65 (ACI.10.3.6.2)


  c c st y c 
ϕ 0.85 0.85f'  π r 2  A  f  0.85 f'  if ϕ = 0.75
  c c st  y c

Compressive reinforcement

d  c( a)
i
fs( i a)  εs  εu
c( a)

f  sign ε s  min ε s  2  10 MPa fy


 
5
 
fs  f if ε s  0

fs  f  0.85 f'c otherwise

For spirally reinforced members

d t  c( a)
ϕ( a)  εt  εu
c( a)
if ϕ = 0.65
0.9 if ε t  0.005

0.65 if ε t  0.002

 
250
0.65  ε t  0.002  otherwise
3
if ϕ = 0.75
0.9 if ε t  0.005

0.75 if ε t  0.002

 
0.75  ε t  0.002  50 otherwise
  ns  
 
ϕPn ( a)  min ϕ( a)  0.85 f'c Ac( a) 
  As0 fs(i a)  ϕPn.max

  i 1  

 ns 
 
ϕMn ( a)  ϕ( a)  0.85 f'c Ac( a)  x c( a) 
  As0 fs( i a)   rc  di
 i 1 
rc
a  0   2rc
30

Interaction Diagram
6000

4800
Axial Load

3600

2400

1200

0
0 200 400 600 800 1000

Benind Moment

You might also like