Axial Testing BRB
Axial Testing BRB
Axial Testing BRB
Braces
Authors:
Daniel Thomas Item
Corey Huang
Advisor:
Graham Archer, PhD., PEng.
Spring 2019
California Polytechnic State University
San Luis Obispo, CA
1
Table of Contents:
Introduction . . . . . . . . . . 2
Initial Hypothesis . . . . . . . . . 4
Testing Materials . . . . . . . . . 4
Testing Setup . . . . . . . . . . 4
Initial Testing . . . . . . . . . . 8
Initial Results . . . . . . . . . . 9
Final Hypothesis . . . . . . . . . 10
Final Testing . . . . . . . . . . 11
Final Results . . . . . . . . . . 13
Sources of Error . . . . . . . . . 18
Conclusion . . . . . . . . . . 19
Future Potential . . . . . . . . . 20
2
The testing and research in significant lateral force resisting systems is important to
furthering the resilience, adaptability, and economy of structural systems. Lateral force resisting
systems is still a fairly young concept to many structural practices. The new potential methods of
manufacturing a buckling restrained brace (BRB) frame is open for pursuing recycling practices
such as the reuse of non-disposable materials. Also, these new methods of formulating BRB
systems will open doors for structural engineers to pursue a lateral system that better fits their
Introduction:
The buckling restrained brace frame is a lateral system that has been used for over 30
years. Designed for minimal usage in the 1980’s, the system allows for a building mechanism
that both dissipates energy from lateral motion, as well as resists significant lateral forces.
Buckling restrained braces (BRB) are proprietary members, therefore their usage in construction
often factor in as a fairly significant cost for buildings. Generally, bids for building projects work
toward an effort to decrease the overall cost of the building while also meeting code
requirements. This project works toward observing the performance of BRBs when utilizing
different core encasements to see how they perform relative to each other. BRBs are relatively
thin steel members that are encased with grout as to provide bi-axial compressive strength and
prevent failure by buckling. The restraint on the steel member allows for an overall increased
compressive capacity, as well as match that with the tensile capacity to maximize the energy
dissipation in the system. Allowing the member to withstand similar tensile and compressive
forces is critical in the process of repetitive, cyclic forces during seismic situations. Furthermore,
3
withstand much more significant forces than the interior portion. This allows for the control of
the location of failure within the member during significant seismic activity and the possibility
for the owner to potentially replace the potentially damaged member in the BRBF system.
One of the customizable portions to these systems is the filler material that encases the
steel. Our research dwells on the concept of making comparisons between the usual grout
Initial Hypothesis:
The use of a viscous fluid to encase the steel member of a buckling restrained brace may
provide a significant improvement to the structural compressive capabilities of the system. If so,
the system will also provide damping capacity to the overall structure thereby improving the
seismic performance.
Testing Materials:
● 6 tubes consisting of the following encasement material: 2 grout, 2 tar, and 2 flubber
● Epoxy
Testing Setup:
We used the Riehle Machine in the High-Bay Lab at California Polytechnic State
University, San Luis Obispo because it was all that was available to provide us a force with a
correlating displacement to the nearest thousandth of an inch. The machine is capable of reading
forces on a dial to a precision of 5 pounds. The machine is incapable of providing tension and
compression loading in a cyclic fashion, so we decided to take the liberty of cycling the members
through a series of compressive loading, followed by a tension test. That being said, our test
specimen underwent a series of slow, static loading. Dynamic testing was not a means of
experiment we could undergo due to time constraints and a lack of sufficient resources.
5
For the compression tests, we crafted two significantly thick steel plates to pin the ends of
the rods into place. They were crafted to friction-fit the machine we had and allow no rotational
freedom to the ends of the system. This allowed for the member to be forced into solely axial
stresses and provide as little initial P-Delta effects to the ends as possible.
Construction of the test specimen consists of cutting the rods and PVC pipes to their
designated, equal lengths. The ends of the zinc rods are grinded down in order to be able to
screw the respective nuts into place. ¼” holes are drilled into the centers of the rubber stoppers
and slid into place on the zinc rod. Heavy amounts of grease is applied to the zinc rods prior to
being put into the encasement PVC. This is to ensure that there is no bonding between the rod
and the filler materials. The initial stopper is coated with epoxy prior to being jammed into the
end of the PVC. Once the stoppers are sealed into place, the designated material is poured into
the tubes. Constant vibration and motion is applied to the materials in order to minimize any air
pockets from existing. Once full, the second rubber stopper is applied to the open end of the PVC
and epoxied into place. The epoxy is left to cure for a minimum of 24 hours to ensure its full
strength. The samples with grout material is given a minimum of 7 days to cure in order to
The grout is constructed with a ratio of 3 parts sand to 1 part cement, as well as gradual
learned in the constructing of grout to provide an approximate f’c capacity of 2500 psi (ARCE
305, ARCE Dept. Cal Poly SLO). The tar material used is a Latex-ite Brand substance that has a
general purpose of road-crack repairs found at a local department store. The flubber material was
constructed with a recipe ratio of 3 teaspoons Borax that has been mixed with 2 cups Elmer’s
Initial Testing:
The tar and flubber reacted in a fashion that can be categorized as a non-newtonian
liquid. This is defined as a material that reacts similar to a solid upon impact forces and a liquid
when applied with slow, gradual loading. The materials generally have poor shear capacity when
given prolonged loading. Due to this, the experiment proved to be unsuccessful in acquiring data
for axial compression since the materials provided no resistance against the buckling of the
slender rods. The Rayleigh machine began to apply loading, but the significant slenderness of the
2 foot long rods was too small to be traced by the large machine. The rods gave way to
Initial Results:
The failures of the test specimen revealed a significant learning experience for the two of
us. Going on into the structural engineering world, there is an understanding that some of the
greatest feats learned in the community is what comes out of the failures of the past. Going into
the experiment, we had an understanding that a viscous liquid held properties of resisting motion
energy and providing damping. With this knowledge, we had hoped that a viscous liquid could
also resist the motion of what it encases, similar to the qualities experienced when walking
through a dense liquid and experiencing a significant strain to the human legs. What we failed to
predetermine was that this stress from the liquid was not significant enough to provide a bi-axial
Final Hypothesis:
The use of solely compressed aggregate to encase the steel rod may provide significant
axial compressive capacities to the BRB system. The densities of the aggregate are the key to the
overall compressive strength and comparing the specimens is the goal of the experiment. Even if
the qualities are not as great as the grout substance, it will allow for these BRB members to be
Final Testing:
The same materials and setup were used with a change in the encasement materials. For
the grout, the 3 parts sand to 1 part cement ratio with water still holds. For the aggregate, we
tested two different sizes in the PVC. One aggregate we used was sand that we categorized as
fine. The other consisted of small pebbles that we categorized as coarse. The method of
constructing these specimen remained the same as the previously constructed test specimens.
Compression testing of the test specimens varied between 100lb increments for grout
specimen and 50lb increments for aggregate specimens. The increased increment scale for the
grout specimen was with the understanding that the grout substance was able to withstand a
higher compressive load than the aggregates alone. Unlike the flubber and tar substances, the
aggregates were able to take on significant loading and provide reasonable force-displacement
data.
Once compression tests were cycled on each of the test specimens we had the machine
switched from compression mechanics to tension. Once set up, we utilized the two clamping
mechanisms on the Riehle machine that hold the ends of the member being stretched. In order
for the rods to stay in place, we tightened nuts onto each end to give the clamps something to
grasp to. Once the tests were completed, we observed the nuts and noticed they did not have any
give to them. This ensured that they worked very well for our experiment. We took the members
Final Results:
From the graph below, we concluded that the grout specimen performed the best
compared to the fine and coarse aggregate. The grout specimen begins yielding around 600lbs
while the fine and coarse aggregate begins yielding around 300lbs and 250lbs respectively. The
fine aggregate and grout follow the same elastic curve as each other, however the fine aggregate
specimen yields at a much lower force than the grout specimen. We found there to be a similar
slope in the fine aggregate and the grout to be due to the fact that the fine aggregate is what was
used in the creation of the grout specimens. As we had predicted, the grout material was able to
perform significantly better than the fine and coarse aggregates in terms of ultimate loading
capacity. However, the fact that the fine aggregate was able to hold the same stiffness as the
grout material shows that it holds some significant quality of being an energy dissipating system.
The coarse aggregate showed results that not only were weaker than the other two, but held
much poorer properties. It remains a much less capable system, but is also able to provide some
significant resistance. I would not overall count this out as a usable mechanism for future
mechanisms.
Grout 2 shows a large displacement on the first segment of loading, followed by little
displacement from then on. The large initial displacement is likely due to the fact that upon
loading the system, the materials took some time to set into place before distributing the loads
appropriately. After the initial loading, the stiffness of the specimen increased greatly. This
would explain the great increase in displacement on the system after the first segment of loading
from an initial state of 0” displacement to 0.035”. This could also be explained as the grout
material actually having initially bonded to the rods encased. In that case, the initial loading on
the specimen would have to be extracted from the analysis and the secondary loading would be
our primary focus. In that case, the grout material would not only have provided a significantly
greater compressive capacity than the other two specimens, but also would hold a much greater
stiffness as well.
Unlike the grout specimen, both fine and coarse aggregate show no change in stiffness
between load tests which indicates proper set-up in the Riehle machine. Both aggregates have
similar displacement patterns to each other, however the coarse aggregate deforms more than the
fine aggregate. The coarse aggregate also yields at a lower force than the fine aggregate, while
also deforming less than the fine aggregate past the yield point.
After testing for compression, we analyzed the tensile capacities of the systems. What we
noticed was that there is no significant difference between the tensile capacity of the different
BRB specimens. However, a common failure mechanism between each specimen was that the
Unlike an ideal BRB, the encased portion of the rods were not reduced compared to the
exterior, therefore the location of failure were not controlled to be in the middle of the BRB.
Although this had little effect on the results of the compressive capacities, it was reason for our
tensile capacities to be relatively flawed. Another important thing to note is the tensile capacity
of the grout 1 specimen. Due to the significant higher ultimate tensile strength of the rod, it
became known that the grout 1 specimen used a steel rod instead of a zinc rod. Therefore, data
from the grout 1 specimen was excluded in the overall analysis and comparisons.
17
Sources of Error:
One of the possible sources of error is in the creation of the axial testing components. The
alignment of the bottom and top plates are not certainly centered, therefore having some
accidental eccentricity in the loading of the specimens is quite possible. This would allow for the
members to buckle at a lower load than expected. However, as these force values may be
skewed, they all underwent the exact same procedure so their values are still reasonable to
compare. Another source of error existed in the precision of our values. The forces were read on
a dial, while the deformations held a precision of the nearest thousandth of an inch. The
deformations were so small that at least one more significant figure would have been good to
track a more distinct force-displacement curve. Another source of error would be the usage of
PVC pipe as the ultimate encasement boundary that we used. This material, as capable as it was
to hold the encasement material in place, also exhibited elastic properties. That being said, it
showed some give to buckling during our tests. If given the chance to go back and change the
setup, I would have probably pursued a much stiffer exterior member than PVC. We also would
have probably gone with full steel rods to see a lot more of the action being put in the
encasement materials and to have very little worry as to the rod exhibiting failure mechanisms on
us. Furthermore, we would have liked to use a method of debonding that was much more
efficient than the grease. We believe that the rods were still able to bond to the encasement grout
material which had effects on our initial data prior to debonding during loading.
19
Conclusion:
Given the results, the grout specimen is able to perform significantly better than the other
two specimens. However, this does not rule out the usage of the other two aggregate materials as
a potential for usage in projects that don’t necessarily need such a significant load resistance. The
fine aggregate was able to hold a similar elastic stiffness to that of the grout, leading us to
believe that the aggregate in each system is pertinent to the stiffness of encasement on the
slender rod inside. The factor that allowed for the higher loading capacity would be the bonding
cement material that provided properties of preventing the aggregate from splitting away from
each other under significant stress. The coarse aggregate performed poorly in comparison
leading us to believe that a finer aggregate material is much more capable of remaining stiff to
the stresses that is undergoes. The coarse aggregate also shows large initial displacements in the
first loading scenario leading us to believe that it has a very high potential for slippage when
given stress. We believe that this is due to the significantly low density of the material and the
possibility for large air pockets to make way for the material to move to.
20
Future Impacts:
The concept of a BRB system is still young to this world, as is many of the lateral force
resisting systems out there. The potential to extend this project further into research is still very
open to optimization and testing to provide a greater understanding and ultimately be able to see
the versatility in the system as structural engineers look to customize their lateral systems to the
needs of their specific project. To anyone looking to further research on this concept, an idea that
would be great to seek out are the different qualities of bonding materials in the aggregates. We
have an understanding that cement is a very strong bonding material and is very unlikely to give
way under significant stress. However, other bonding agents such as lime is something that could