Design Calculations. Column Design.: Residential House

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Job No. Sheet No. Rev.

STR-034-19
RESIDENTIAL HOUSE. Drg. Ref.
DESIGN CALCULATIONS.
Made by Date Checked
COLUMN DESIGN. ak. 21-Aug-2019

RESIDENTIAL HOUSE.
DESIGN CALCULATIONS.
COLUMN DESIGN.

Notes:
None

History
Date Time Name Note
21-Aug-2019 10:03 Wilson New

Input Data

General Specification
Design code EN 1992-1-1:2004 Eurocode 2
Country <undefined>
Bending Axes Biaxial
Imperfection Moment yy Yes
Imperfection Moment zz Yes
2nd Order Moments Yes
Width to Depth Ratio Yes
Height to Thickness Ratio Yes

Column Section and Slenderness


Sec. STD R 230. 230.
Clear height between end restraints y 3.000 m
Clear height between end restraints z 3.000 m
Compression member in regular frame No
EC2 Buckling Mode y Cl 5.8.3.2(2)(c)
EC2 Buckling Mode z Cl 5.8.3.2(2)(c)

Notes:
Sections are defined as follows:
STD R Depth, Width => Rectangular Section

Concrete Material Specification


Prop. Name fck Max. Agg. Size Tensile Static E Gamma Maximum
Strength c Strain
[N/mm²] [mm] [N/mm²] [N/mm²]
Column C20/25 20.00 20.00 1.474 29960. 1.500 0.003500

Reinforcement Specification
Prop. Name fy Bond Coeff. Bond Coeff. Young's Gamma s Maximum
Tension Compr. Modulus Strain
[N/mm²] [N/mm²]
Main 500B 500.0 0.5000 0.6300 200000. 1.150 0.05000
Links 500B 500.0 0.5000 0.6300 200000. 1.150 0.05000

Loads
Load Case Axial Design Moments
Force 'N'
Top Bottom
Myy Mzz Myy Mzz
[kN] [kNm] [kNm] [kNm] [kNm]
1 730.0 8.000 8.000 0.0 0.0

Analysis Cases
Analysis Case Name Description Moment Ratio(y) Moment Ratio(z) Creep Coefficient

1 Analysis Case 1 1L1 0.6500 0.6500 2.000

Covers
Min. Nominal Cover (back) 20.00 mm
Min. Nominal Cover (front) 20.00 mm
Min. Nominal Cover (left) 20.00 mm
Min. Nominal Cover (right) 20.00 mm

Available Bar Sizes


Name Size
[mm]
0 8.000
1 10.00
2 12.00
3 16.00
4 20.00
5 25.00
6 32.00
7 40.00

Bar Limits
Minimum Maximum
[mm] [mm]
Main 12.00 32.00
Links 8.000 10.00

Checks and Limits


Max. Area of Reinf. EN 1992-1-1:2004 Eurocode 2
Min. Area of Reinf. EN 1992-1-1:2004 Eurocode 2
Min. Bar Size EN 1992-1-1:2004 Eurocode 2
Min. No of Bars EN 1992-1-1:2004 Eurocode 2
Max. bar spacing (tension) EN 1992-1-1:2004 Eurocode 2
Max. bar spacing (compression) 300.0 mm
Min. Bar Spacing EN 1992-1-1:2004 Eurocode 2

Program ADC Version 8.4.0.12 Copyright © Oasys 1990–2014 Page 1


Printed 21-Aug-2019 Time 10:54
Job No. Sheet No. Rev.

STR-034-19
RESIDENTIAL HOUSE. Drg. Ref.
DESIGN CALCULATIONS.
Made by Date Checked
COLUMN DESIGN. ak. 21-Aug-2019
Minimum Maximum
[mm] [mm]

Link size EN 1992-1-1:2004 Eurocode 2


Maximum Link Spacing EN 1992-1-1:2004 Eurocode 2
Top and bottom of column connected No
to beams or slabs
Cover check: bar size EN 1992-1-1:2004 Eurocode 2
Cover check: aggregate size EN 1992-1-1:2004 Eurocode 2
Deviation (Cdev) 10.00 mm

Bar Arrangements
Clear Distance Between Rows of Bars EN 1992-1-1:2004 Eurocode 2

Nr of Bars Bar Arrangements


4 4_1

Eurocode 2 Nationally Determined Parameters


The following Nationally Determined Parameters (NDPs) are given the default values that are recommended in Eurocode 2.

Clause Parameter Default Value


5.2 0 1/200
8.2 k1 1
8.2 k2 5 mm
9.5.2(2) Asmin max(0.10NEd/fyd,0.002Ac)
9.5.2(2) Asmax 0.04Ac
9.5.2.9 min 8 mm
9.5.3(3) scl,tmax min(20 x diamin, min(width, depth), 400 mm)

The following NDPs are country specific and may found in its National Annex.

Clause Parameter Value


3.1.6 cc 1.000

Invalid Sections
Sec. Bar Bar Link Inner Outer Width Height to Min. Max. Min. Max. Max. Min. Min. Link Cover Cover
Arrangement Size Size Cover Cover to Thickness Area Area Bar Bar Bar Bar No Size vs. vs.
or or Depth Ratio of of Spacing Spacing Spacing Size of Agg. Bar
Section Section Ratio Reinf. Reinf. in in Bars Size Size
Size Size Tens. Comp.
[mm] [mm]
2 4_1 12 10 X
4 4_1 16 10 X
6 4_1 20 10 X
8 4_1 25 10 X
9 4_1 32 8 X
10 4_1 32 10 X X

Notes:
'X' indicates a section that fails to comply with the requirement specified by the relevant table column - for any analysis case.
A number, e.g. '2', indicates an analysis case for which a section fails to comply with EC2's requirement for minimum area of reinforcement.

Program ADC Version 8.4.0.12 Copyright © Oasys 1990–2014 Page 2


Printed 21-Aug-2019 Time 10:54

You might also like