Max. Condensing Operating Condition in Summer

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Q4036N-JS4(e)

5. 汽封漏汽计算Steam sea leakage calculation

5.1 各段汽封漏汽流量Steam sea leakage flow at all sections

后 汽 封 Rear
前 汽 封Front steam seal
steam seal

段号Section No. 1 2 3 4 5 1 2

汽封齿数Steam seal teeth number 80 30 10 10 10 10 5

汽封直径Steam seal diameter cm 62.0 62.0 62.0 44.8 44.8 33.0 33.0

汽封间隙Steam seal gap cm 0.05 0.05 0.05 0.05 0.05 0.05 0.05

漏汽面积Steam leakage area cm2 9.739 9.739 9.739 7.037 7.037 5.184 5.184

rated condensing operating condition 3.162 1.764 0.415 -0.122 0.047 -0.128 0.065

max. power condition 3.464 1.932 0.458 -0.117 0.047 -0.128 0.065
漏汽量 condensing operating condition in summer 3.269 1.816 0.426 -0.120 0.047 -0.128 0.065
Steam
leakage max. condensing operating condition in summer 3.641 2.019 0.479 -0.114 0.047 -0.128 0.065
amount
t/h high pressure heater cut condition 2.990 1.862 0.432 -0.121 0.048 -0.128 0.065

75% condensing operating condition 2.399 1.364 0.319 -0.131 0.048 -0.128 0.065

50% condensing operating condition 1.670 0.971 0.226 -0.137 0.048 -0.128 0.065

5.2 进入各换热器的流量(包括阀杆漏汽)Flow rate into the heat exchangers (including steam leakage from valve rod)

1号高 3号低 1号低


加No. 1 加No. 3 加No. 1 汽封加热器
至除氧器to 自密封装置self
漏汽去向steam leakage direction high low low steam seal
deaerator sealing device
pressur pressur pressur hedater
e heater e heater e heater

rated condensing operating condition 1.398 1.349 0.537 1.20 -0.362 0.212

max. power condition 1.532 1.474 0.575 1.20 -0.357 0.212

condensing operating condition in summer 1.453 1.39 0.546 1.20 -0.360 0.212
流量
flow max. condensing operating condition in summer 1.622 1.54 0.593 1.20 -0.354 0.212
rate t/h
high pressure heater cut condition 1.128 1.43 0.553 1.20 -0.362 0.213

75% condensing operating condition 1.035 1.045 0.45 1.20 -0.372 0.213

50% condensing operating condition 0.699 0.745 0.363 1.20 -0.378 0.213