1. Pump data 4
Table of contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. Performance range 7
Performance range, TPE2, TPE3, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Performance range, TPE2 D, TPE3 D, twin-head operation, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Performance range, 2-pole, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Performance range, 2-pole, PN 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Performance range, 4-pole, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Performance range, 4-pole, PN 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3. Product range 12
Product range, 2-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Product range, 4-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4. Operating conditions 18
System and test pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Sound pressure level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Installation altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5. Pumped liquids 20
Liquid temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
List of pumped liquids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Recommended shaft seal for water-glycol mixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
9. TPE2 32
10. TPE3 36
14. Communication 95
Communication with TPE2, TPE2 D, TPE3, TPE3 D and TPE pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
2
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Table of contents
Motors for TPE2, TPE2 D, TPE3, TPE3 D pumps and 2.2 - 11 kW 2-pole motors and 1.5 - 7.5 kW 4-pole motors fitted
on TPE Series 1000 pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
MGE motors, 11 to 18.5 kW, 4-pole, and 15 to 22 kW, 2-pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Identification of functional module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
3
1 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
1. Pump data
Pump data
4
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
1
TPE3 pumps Why select a TPE pump?
Pump data
A pump with electronic speed control offers these
obvious benefits:
• energy savings
• increased comfort
• control and monitoring of the pump performance
• communication with the pump.
ATEX-approved TP pumps
5
1 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Identification
Pump data
Code Example B Q B E
6
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
2
2. Performance range
Performance range
Performance range, TPE2, TPE3, PN 6, 10, 16
See page 126 for performance curves.
+
>P@
73('
73('
4>PñK@
+
>P@
73('
73('
TM05 8198 4914
4>PñK@
7
Performance range
2
8
S +
>N3D@ >P@ 73'73(
31SROH+]
Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 125.
4>PñK@
4>OV@
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
160
100-1510
140
100-1360
See page 154 for performance curves.
120 100-1200
100-1040
1000
100
Performance range, 2-pole, PN 25
900 100-940
90
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
800
80
100-760
700
70
600
60
500
50
20 30 40 50 60 70 80 100 150 200 300 400 500
Q [m³/h]
6 7 8 9 10 20 30 40 50 60 70 80 90 100 Q [l/s]
9
Performance range
2
Performance range
2
10
p H
[kPa] [m]
100 TP(D), TPE
900 150-960
800 80
PN 6-16, 4-pole, 60 Hz
150-810
700
150-700
300
600 20 -7 5
60 0
150-610 0-
77
20 0 30
0- 0-6
500 50 80-510 6 80 40
20 30
125-480 0- 0-
80-460 15 60
0
63
35
12 20 30 0
0-
0-4
400 40 5-4 80 0- 0-
68
100-470 54 55
0
80-410 20 0
0
35
20 20
0-
0- 0-
10 150-440 49
0
54
50
0 0
0
10 -390 20
0 1 20 0
See page 156 for performance curves.
30
300 30 50-340 -35 50-4 -4
35
65- 0-4
330 0 12 0 4 0
100 0 1 30 2
0-4
5- 00
80-340
30
-34
40
0 36 1 5 50 - -3
0
50
-290 12 40 15 360 0- 0-
0- 36
50-240 5-
2 30 2 0 0 40
80-280 80 1 0 0- 30 0
200 40-230 100-260 5 32
20 65-230 8 0 125 0-2
0
0-
36
32-190 -23
0
-23
0
40 20
0- 0
100-240 28 350-400
50-180 15 0
15
10 0 -
20 3
0
65-190 100 0-2 21 0- 00
-17 00 0 25 -2
15 40-180 80-170 0 125- -22
0
0 70
10 12
40-110 80-150 0-1 5-1 15
0-2
30 60 0-
150-130 2
Performance range, 4-pole, PN 6, 10, 16
10
12 20 00
100 10 65-130 5-
13 0-
32-120 50-115 80-110 12
5 19
90 5-
13 0 300-230
0
20
80
0-
8 125-110
14
100-100
0
70 50-100
65-80
60 6 200-110
40-80 80-80 100-80
50 5 125-80
32-80 50-80
40 4
200-80
Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 125.
30 3
32-40 50-40 65-40 80-40 100-40
40-40
20 2
4 6 8 10 15 20 30 40 60 80 100 150 200 300 400 600 1000 1500 2000 3000
Q [m³/h]
2 3 4 5 6 7 8 910
10 20 30 40 50 60 80 100 200 300 400 500 Q [l/s]
150-610 20
0-6 30
100-560 12 80 0-
500 50 5- 20 64
58 0-6 0
12 0 00 30
5-5 20 0-
100-470 63
50 0-5 0
35
12 40
0-
400 20 30
40 5-4 15 0-
68
0- 0-4
0
80 20 55
Performance range, 4-pole, PN 25
48 90 0
100-390 12 150- 0
0-
50
35
5- 20 0
0-
42
0 440 2 0-
54
15 200-430 00 44
0
100-340 0 -4 0
15 -400 00
300 0
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
30
30 12 -36 20
0
35
5- 0-
0-4
100-290 36 39
5 0
40
0-4
30
12
50
0-
5-3 20
0
37
40 150- -
0
36
12 340 0
100-240
15
5- 0- 20
28 0-3
0
30
20
0
200 300-360
20 20
15 0-
0- 28
24 0
100-200 15 0
0-
2 30 350-400
125-220 10 0-
15 200-250 27
0
150-180
300-230
100 10
20 30 40 50 60 80 100 150 200 300 400 500 600 800 1000 1500 2000 3000
Q [m³/h]
6 7 8 9 10 20 30 40 50 60 70 80 100 200 300 400 500 Q [l/s]
11
Performance range
2
3 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
3. Product range
Product range
Pump
Impeller Voltage [V]
housing
1 x 200-240 V
3 x 380-500 V
Pump type
Stainless steel 1)
TPE2, TPE2 D
TPE3, TPE3 D
EN-GJL-250
Composite
PES-GF30
Cast iron
PN 6/10
BQQE
BQBE
BAQE
DBUE
PN 10
PN 16
P2 P2
PN 6
[kW] [kW]
TPE2, TPE2 D, TPE3 TPE3 D 32-80 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D 32-120 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D 32-150 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 32-180 ● ● ● ● ● ● ● ● ● 0.55 0.55
TPE2, TPE2 D, TPE3 TPE3 D 32-200 ● ● ● ● ● ● ● ● ● 0.75 0.75
TPE2, TPE2 D, TPE3 TPE3 D 40-80 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D 40-120 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 40-150 ● ● ● ● ● ● ● ● ● 0.55 0.55
TPE2, TPE2 D, TPE3 TPE3 D 40-180 ● ● ● ● ● ● ● ● ● 0.75 0.75
TPE2, TPE2 D, TPE3 TPE3 D 40-200 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3 TPE3 D 40-240 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3 TPE3 D 50-60 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 50-80 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 50-120 ● ● ● ● ● ● ● ● ● 0.55 0.55
TPE2, TPE2 D, TPE3 TPE3 D 50-150 ● ● ● ● ● ● ● ● ● 0.75 0.75
TPE2, TPE2 D, TPE3 TPE3 D 50-180 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3 TPE3 D 50-200 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3 TPE3 D 50-240 ● ● ● ● ● ● ● ● ● 2.2
TPE2, TPE2 D, TPE3 TPE3 D 65-60 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 65-80 ● ● ● ● ● ● ● ● ● 0.55 0.55
TPE2, TPE2 D, TPE3 TPE3 D 65-120 ● ● ● ● ● ● ● ● ● 0.75 0.75
TPE2, TPE2 D, TPE3 TPE3 D 65-150 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3 TPE3 D 65-180 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3 TPE3 D 65-200 ● ● ● ● ● ● ● ● ● 2.2
TPE2, TPE2 D, TPE3 TPE3 D 80-40 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D 80-120 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3 TPE3 D 80-150 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3 TPE3 D 80-180 ● ● ● ● ● ● ● ● ● 2.2
TPE2, TPE2 D, TPE3 TPE3 D 100-40 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D100-120 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3, TPE3 D 100-150 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3, TPE3 D 100-180 ● ● ● ● ● ● ● ● ● 2.2
1) Stainless-steel versions are only available as single-head pumps and with a combined PN 6/10/16 flange.
12
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
3
Product range, 2-pole, PN 6, 10, 16, 25
Product range
Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor
PN 6, 10 combination flange
3 x 660-690 YV 2)
3 x 220-255 ∆V/
3 x 220-277 ∆V/
3 x 380-480 ∆V/
3 x 380-480 ∆V
3 x 380-440 YV
3 x 380-480 YV
3 x 380-480 V
3 x 380-500 V
Pump type
TPE Series 1000 1)
EN-GJS-400-15
Stainless steel
TP Series 200
TP Series 300
EN-GJL-250
Cast iron
Cast iron
Bronze
Bronze
BQQE
DQQE
P2 P2 P2 P2 P2 P2
BQBE
BAQE
DBUE
DAQF
PN 10
PN 16
PN 25
[kW] [kW] [kW] [kW] [kW] [kW]
TP 32-80/2 ● ● ● ● ● ● ● 0.37
TP 32-160/2 ● ● ● ● ● ● ● 0.55
TP 32-220/2 ● ● ● ● ● ● ● 0.75
TP 32-260/2 ● ● ● ● ● ● ● 1.1
TP 32-330/2 ● ● ● ● ● ● ● 1.5
TP, TPD 32-300/2 ● ● ● ● ● ● ● ● 2.2 2.2 2.2
TP, TPD 32-360/2 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 32-450/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 32-550/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 32-680/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 32-820/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP 40-80/2 ● ● ● ● ● ● ● 0.55
TP 40-160/2 ● ● ● ● ● ● ● 0.75
TP 40-240/2 ● ● ● ● ● ● ● 1.1
TP 40-270/2 ● ● ● ● ● ● ● 1.5
TP 40-330/2 ● ● ● ● ● ● ● 2.2
TP 40-390/2 ● ● ● ● ● ● ● 3.0
TP, TPD 40-400/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 40-460/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 40-530/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 40-690/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 40-820/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 40-920/2 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP 50-80/2 ● ● ● ● ● ● ● 0.55
TP 50-160/2 ● ● ● ● ● ● ● 1.1
TP 50-240/2 ● ● ● ● ● ● ● 1.5
TP, TPD 50-250/2 ● ● ● ● ● ● ● 2.2 2.2
TP, TPD 50-300/2 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 50-350/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 50-410/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 50-430/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 50-530/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 50-640/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 50-720/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 50-790/2 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 50-880/2 ● ● ● ● ● ● ● ● 22.0 22.0 22.0
TP, TPD 50-1050/2 ● ● ● ● ● ● ● 30.0 30.0
TP 65-80/2 ● ● ● ● ● ● ● 1.1
TP 65-160/2 ● ● ● ● ● ● ● 1.5
TP 65-240/2 ● ● ● ● ● ● ● 2.2
TP, TPD 65-200/2 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 65-250/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 65-340/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 65-390/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 65-480/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 65-540/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 65-630/2 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 65-740/2 ● ● ● ● ● ● ● ● 22.0 22.0 22.0
TP, TPD 65-910/2 ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 65-920/2 ● ● ● ● ● ● ● 37.0 37.0
TP, TPD 65-1050/2 ● ● ● ● ● ● ● 37.0 37.0
TP 80-160/2 ● ● ● ● ● ● ● 3.0
TP, TPD 80-200/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 80-240/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 80-290/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 80-330/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
13
3 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Product range
Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor
PN 6, 10 combination flange
3 x 660-690 YV 2)
3 x 220-255 ∆V/
3 x 220-277 ∆V/
3 x 380-480 ∆V/
3 x 380-480 ∆V
3 x 380-440 YV
3 x 380-480 YV
3 x 380-480 V
3 x 380-500 V
Pump type
TPE Series 1000 1)
EN-GJS-400-15
Stainless steel
TP Series 200
TP Series 300
EN-GJL-250
Cast iron
Cast iron
Bronze
Bronze
BQQE
DQQE
P2 P2 P2 P2 P2 P2
BQBE
BAQE
DBUE
DAQF
PN 10
PN 16
PN 25
[kW] [kW] [kW] [kW] [kW] [kW]
● Standard
1) TPE pumps are not available in twin-head versions.
2)
2-pole motors above 7.5 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot be operated at 3 X 660-690 YV.
14
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
3
Product range, 4-pole, PN 6, 10, 16, 25
Product range
Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor
Pump
PN 6, 10 combination flange
Impeller Voltage [V] Voltage [V]
housing
3 x 660-690 YV 2)
3 x 380-480 ∆V/
3 x 220-255 ΔV/
3 x 220-277 ΔV/
3 x 380-480 ΔV
3 x 380-440 YV
3 x 380-480 YV
Pump type
3 x 380-480 V
3 x 380-500 V
EN-GJS-400-18-LT
TPE Series 1000 1)
TP Series 300
EN-GJL-250
Cast iron
Cast iron
Bronze
Bronze
BQQE
DQQE
BQBE
BAQE
DAQF
DBUE
PN 10
PN 16
PN 25
P2 P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW] [kW]
TP 32-40/4 ● ● ● ● ● ● ● 0.12
TP 32-80/4 ● ● ● ● ● ● ● 0.25
TP, TPD 32-120/4 ● ● ● ● ● ● ● 0.55
TP, TPD 32-140/4 ● ● ● ● ● ● ● 0.75
TP, TPD 32-190/4 ● ● ● ● ● ● ● 1.1
TP 40-40/4 ● ● ● ● ● ● ● 0.25
TP 40-80/4 ● ● ● ● ● ● ● 0.55
TP, TPD 40-110/4 ● ● ● ● ● ● ● 0.75
TP, TPD 40-150/4 ● ● ● ● ● ● ● 1.1
TP, TPD 40-180/4 ● ● ● ● ● ● ● 1.5
TP, TPD 40-230/4 ● ● ● ● ● ● ● 2.2 2.2
TP 50-40/4 ● ● ● ● ● ● ● 0.25
TP 50-80/4 ● ● ● ● ● ● ● 0.55
TP, TPD 50-100/4 ● ● ● ● ● ● ● 0.75
TP, TPD 50-115/4 ● ● ● ● ● ● ● 1.1
TP, TPD 50-130/4 ● ● ● ● ● ● ● 1.5
TP, TPD 50-180/4 ● ● ● ● ● ● ● 2.2
TP, TPD 50-240/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 50-270/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 50-340/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP 65-40/4 ● ● ● ● ● ● ● 0.37
TP 65-80/4 ● ● ● ● ● ● ● 1.1
TP, TPD 65-130/4 ● ● ● ● ● ● ● 1.5
TP, TPD 65-150/4 ● ● ● ● ● ● ● 2.2 2.2
TP, TPD 65-190/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 65-230/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 65-310/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 65-330/4 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP 80-40/4 ● ● ● ● ● ● ● 0.75
TP 80-80/4 ● ● ● ● ● ● ● 1.5
TP, TPD 80-110/4 ● ● ● ● ● ● ● 2.2 2.2
TP, TPD 80-150/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 80-170/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 80-230/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 80-280/4 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 80-340/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 80-410/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 80-460/4 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 80-510/4 ● ● ● ● ● ● ● 22.0 22.0
TP 100-40/4 ● ● ● ● ● ● ● 1.1
TP 100-80/4 ● ● ● ● ● ● ● 2.2
TP, TPD 100-100/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 100-130/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 100-150/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 100-170/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 100-200/4* ● ● ● ● ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 100-240/4* ● ● ● ● ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 100-260/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 100-290/4* ● ● ● ● ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 100-340/4* ● ● ● ● ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 100-350/4 ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 100-390/4* ● ● ● ● ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 100-470/4* ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP 100-560/4 ● ● ● ● ● ● ● 37.0
15
3 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Product range
Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor
Pump
PN 6, 10 combination flange
Impeller Voltage [V] Voltage [V]
housing
3 x 660-690 YV 2)
3 x 380-480 ∆V/
3 x 220-255 ΔV/
3 x 220-277 ΔV/
3 x 380-480 ΔV
3 x 380-440 YV
3 x 380-480 YV
Pump type
3 x 380-480 V
3 x 380-500 V
EN-GJS-400-18-LT
TPE Series 1000 1)
TP Series 300
EN-GJL-250
Cast iron
Cast iron
Bronze
Bronze
BQQE
DQQE
BQBE
BAQE
DAQF
DBUE
PN 10
PN 16
PN 25
P2 P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW] [kW]
TP 125-80/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP 125-110/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP 125-135/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 125-130/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 125-160/4 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 125-200/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 125-230/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP 125-220/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 125-280/4 ● ● ● ● ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 125-340/4 ● ● ● ● ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 125-365/4 ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 125-420/4 ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 125-480/4 ● ● ● ● ● ● ● ● ● ● ● 37.0 37.0
TP 125-550/4 ● ● ● ● ● ● ● 45.0
TP 125-580/4 ● ● ● ● ● ● ● 55.0
TP 150-130/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP 150-160/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP 150-200/4 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP 150-220/4 ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 150-180/4 ● ● ● ● ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 150-210/4 ● ● ● ● ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 150-240/4 ● ● ● ● ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 150-300/4 ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 150-340/4 ● ● ● ● ● ● ● ● ● ● ● 37.0 37.0
TP 150-360/4 ● ● ● ● ● ● ● ● ● ● ● 30.0
TP 150-400/4 ● ● ● ● ● ● ● ● ● ● ● 37.0
TP 150-440/4 ● ● ● ● ● ● ● ● ● ● ● 45.0
TP 150-480/4 ● ● ● ● ● ● ● ● ● ● ● 55.0
TP 150-610/4 ● ● ● ● ● ● ● ● ● ● ● 75.0
TP 150-700/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 150-810/4 ● ● ● ● ● ● ● ● ● ● ● 110.0
TP 150-960/4 ● ● ● ● ● ● ● ● ● ● ● 132.0
TP 200-80/4 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP 200-110/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP 200-140/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP 200-190/4 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP 200-210/4 ● ● ● ● ● ● ● 22.0 22.0
TP 200-250/4 ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP 200-280/4 ● ● ● ● ● ● ● ● ● ● ● 37.0
TP 200-320/4 ● ● ● ● ● ● ● ● ● ● ● 45.0
TP 200-360/4 ● ● ● ● ● ● ● ● ● ● ● 55.0
TP 200-390/4 ● ● ● ● ● ● ● ● ● ● ● 75.0
TP 200-400/4 ● ● ● ● ● ● ● ● ● ● ● 75.0
TP 200-430/4 ● ● ● ● ● ● ● ● ● ● ● 55.0
TP 200-440/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 200-490/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 200-500/4 ● ● ● ● ● ● ● ● ● ● ● 110.0
TP 200-540/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 200-600/4 ● ● ● ● ● ● ● ● ● ● ● 110.0
TP 200-680/4 ● ● ● ● ● ● ● ● ● ● ● 132.0
TP 200-770/4 ● ● ● ● ● ● ● ● ● ● ● 160.0
TP 300-230/4 ● ● ● ● ● ● ● ● ● ● ● 45.0
TP 300-270/4 ● ● ● ● ● ● ● ● ● ● ● 55.0
TP 300-360/4 ● ● ● ● ● ● ● ● ● ● ● 75.0
TP 300-370/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 300-440/4 ● ● ● ● ● ● ● ● ● ● ● 110.0
TP 300-550/4 ● ● ● ● ● ● ● ● ● ● ● 132.0
TP 300-630/4 ● ● ● ● ● ● ● ● ● ● ● 160.0
16
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
3
Product range
Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor
Pump
PN 6, 10 combination flange
Impeller Voltage [V] Voltage [V]
housing
3 x 660-690 YV 2)
3 x 380-480 ∆V/
3 x 220-255 ΔV/
3 x 220-277 ΔV/
3 x 380-480 ΔV
3 x 380-440 YV
3 x 380-480 YV
Pump type
3 x 380-480 V
3 x 380-500 V
EN-GJS-400-18-LT
TPE Series 1000 1)
TP Series 300
EN-GJL-250
Cast iron
Cast iron
Bronze
Bronze
BQQE
DQQE
BQBE
BAQE
DAQF
DBUE
PN 10
PN 16
PN 25
P2 P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW] [kW]
TP 300-640/4 ● ● ● ● ● ● ● ● ● ● ● 200.0
TP 300-750/4 ● ● ● ● ● ● ● ● ● ● ● 250.0
TP 350-400/4 ● ● ● ● ● ● ● ● ● ● ● 132.0
TP 350-450/4 ● ● ● ● ● ● ● ● ● ● ● 160.0
TP 350-540/4 ● ● ● ● ● ● ● ● ● ● ● 200.0
TP 350-680/4 ● ● ● ● ● ● ● ● ● ● ● 250.0
● Standard
* Only TP pumps are available in PN 25.
1) TPE pumps are not available in twin-head versions.
2)
4-pole motors above 4 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot be operated at 3 x 660-690 YV.
17
4 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
4. Operating conditions
Operating conditions
18
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
4
Installation altitude In order to maintain the galvanic isolation and ensure
Operating conditions
correct clearance according to EN 60664-1:2007, you
Pump with standard motor must adapt the supply voltage to the altitude:
If the ambient temperature exceeds maximum values
Supply voltage [V]
or if the motor is located more than 1000 m above sea
level, the motor output, P2, must be reduced due to the 500
480
230
P2
50
20 25 30 35 40 45 50 55 60 65 70 75 80 Note:
t [°C] Motors installed more than 1000 m above sea level
1000 2250 3500 4750 m must not be fully loaded due to the low density and
Fig. 2 Maximum motor output in relation to ambient consequent low cooling effect of the air.
temperature and altitude If the motor is to operate at ambient temperatures
between 50 and 60 °C, select an oversized motor.
Pump with Grundfos MGE motor Contact Grundfos.
Description
MGE motors:
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
P2 [%]
100
90
TM05 5243 3717
80
70
60
0 500 1000 1500 2000 2500 3000 3500 Altitude [m]
19
5 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
5. Pumped liquids
Pumped liquids
20
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
5
List of pumped liquids Legend
Pumped liquids
TP and TPD pumps are designed for circulation A
May contain additives or impurities that may cause shaft seal
problems.
systems with constant flow, TPE2, TPE2 D, TPE3,
The density and/or viscosity differ from those of water.
TPE3 D and TPE pumps for systems with variable flow. B
Consider this when calculating motor and pump performance.
Thanks to their design, you can use the pumps in a C The liquid must be oxygen-free (anaerobic).
wider liquid temperature range than pumps of the
D Risk of crystallisation or precipitation in shaft seal.
canned rotor type.
E Insoluble in water.
A number of typical liquids are listed below.
F The shaft seal rubber parts must be replaced with FKM rubber.
You can use other pump versions, but we consider the
ones stated in the list to be the best choices. G Bronze housing or impeller required.
The list is intended as a general guide only, and it Risk of formation of ice on the standby pump.
H
The risk only applies to TP, TPE Series 200 pumps.
cannot replace actual testing of the pumped liquids
and pump materials under specific working conditions.
If in doubt, we recommend that you fill in the form
shown on page 222 and contact Grundfos.
Use the list with some caution, as factors such as
concentration of the pumped liquid, liquid temperature
or pressure may affect the chemical resistance of a
specific pump version.
Shaft seal
Additional
Pumped liquids Notes
information TP Series 300 TP Series 300
TPE2, TPE3 TP Series 200
PN 16 PN 25
Water
BQBE BQBE
< 120 °C BQQE DQQE 4)
Groundwater BQQE BQQE
> 120 °C BQBE DAQF2) + 4) DAQF 4)
BQBE BQBE BAQE DAQF
< 120 °C
BQQE BQQE BQQE DQQE
Boiler-feed water
< 140 °C BQBE DAQF 2) DAQF
< 150 °C DAUE2)
BQBE BQBE BAQE DAQF
District heating water < 120 °C
BQQE BQQE BQQE DQQE
BQBE BQBE BAQE DAQF
< 120 °C
BQQE BQQE BQQE DQQE
Condensate
BAQE
> 120 °C BQBE DAQF
DAQF2)
BQBE BQBE BAQE
< 120 °C DAQF
Softened water C BQQE BQQE BQQE
> 120 °C BQBE DAQF2) DAQF
pH > 6.5, 40 °C, BQBE BQBE
Brackish water G BQQE DQQE
1000 ppm Cl- BQQE BQQE
Coolants
Synthetic oils
21
5 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Pumped liquids
Shaft seal
Additional
Pumped liquids Notes
information TP Series 300 TP Series 300
TPE2, TPE3 TP Series 200
PN 16 PN 25
Vegetable oils
Cleaning agents
Oxidants
Salts
Alkalis
Ammonium hydroxide < 100 °C, < 30 % BQQE BQQE BQQE DQQE
Calcium hydroxide A < 100 °C, < 10 % BQQE BQQE BQQE DQQE
Potassium hydroxide A < 20 °C, < 20 % BQQE BQQE BQQE DQQE
Sodium hydroxide A < 40 °C, < 20 % BQQE BQQE BQQE DQQE
1)
Do not use BAQE for potable water. For potable water, we recommend that you use a BBQE shaft seal.
2) The shaft seal is not standard, but available on request.
3)
Applies only for TPE2.
4)
Do not use for potable water.
22
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
5
Recommended shaft seal for water-glycol mixture
Pumped liquids
Glycol content
[%]
50
40
30
BQQE
/DQQE
10
-25-20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
Temperature [°C]
Glycol content
[%]
50
40
30 BQQV
TM06 1034 1514
20
10
-10 0 10 20 30 40 50 60 70 80 90
Temperature [°C]
23
6 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
226
Materials
TP Series 200
5 4
GR8261
2
Technical data
Flow rate: Up to 90 m3/h Fig. 9 Sectional drawing of a TP Series 200 (flanged
Head: Up to 27 m model)
Liquid temperature: -25 to +140 °C
Material specification, Series 200
Max. operating pressure: Up to 16 bar
Direction of rotation: Counterclockwise Pos. Component Material EN/DIN
Cast iron EN-GJL-250, 0.6020
Construction 1 Pump housing
bronze CuSn10 2.1093
Grundfos TP Series 200 pumps are single-stage, 2 Impeller Stainless steel 1.4301
close-coupled pumps with in-line inlet and outlet ports 3 Shaft Stainless steel 1.4305
24
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
227 6
Mechanical shaft seal Features and benefits
25
7 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Construction
Grundfos TP, TPD Series 300 pumps are single-stage,
close-coupled pumps with in-line inlet and outlet ports
of identical diameter.
The pumps are fitted with a fan-cooled asynchronous
motor. Motor and pump shafts are connected via a
rigid sleeve coupling.
Most TP Series 300 pumps are available as
single-head, TP, and twin-head, TPD pumps.
GR8259
TP Series 300 pumps have PN 16 flanges or PN 25
flanges.
Fig. 10 TP Series 300 The pumps are fitted with an unbalanced or a balanced
mechanical shaft seal.
Technical data The pumps are of the top-pull-out design, that is you
can remove the power head (motor, pump head and/or
PN 16 version PN 25 version
motor stool and impeller) for maintenance or service
3
Flow rate [m /h] Up to 2000 Up to 2000 while the pump housing remains in the pipes.
Head [m] Up to 93 Up to 150 The pump housing is provided with a replaceable wear
ring to ensure high pump efficiency for life.
Liquid temperature [°C] -25 to +140 -40 to +150*
The twin-head pumps are designed with two parallel
Maximum operating
pressure [bar]
16 25 power heads. A non-return flap valve in the common
outlet port is opened by the flow of the pumped liquid
Direction of rotation Clockwise and prevents backflow of liquid into the idle pump
* At 120 to 150 °C, the maximum operating pressure is less than 23 head.
bar. As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
The impeller is hydraulically balanced to minimise axial
forces.
TP, TPD, TPE Series 300 pumps are equipped with
high-efficiency motors.
TP Series 300 pumps with bronze impeller are suitable
for pumping brine.
26
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
7
Materials TP Series 300, PN 25
Connections
TP Series 300 pumps have PN 16 or PN 25 flanges. All
dimensions are according to ISO 7005-2 or EN 1092-2.
27
7 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
28
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
8
HH
[m]
[m]
100 %
Fig. 12 TPE Series 1000
Technical data
Flow rate: Up to 340 m3/h
Head: Up to 90 m
Liquid temperature: -25 to +140 °C
29
8 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
The charts below show possible control modes of the pumps in different applications.
TPE Series 1000 pumps
In systems with relatively small pressure losses in the distribution pipes. Constant differential pressure
• Two-pipe heating systems with thermostatic valves and the following:
– sized for natural circulation
H
– small pressure losses in those parts of the system through which the total
quantity of water flows, for example boiler, heat exchanger and distribution
pipe up to the first branching, or modified to a high differential temperature All
between flow pipe and return pipe, for example district heating.
• Underfloor heating systems with thermostatic valves.
• One-pipe heating systems with thermostatic valves or pipe balancing valves.
• Primary circuit pumps in systems with small pressure losses in the primary
circuit. Q
Constant pressure
Constant temperature
All
Q
Constant curve
If an external controller is installed, the pump is able to change from one constant H
curve to another, depending on the value of the external signal.
The pump can also be set to operate according to the maximum or minimum
curve: All
• Use the maximum curve mode in periods in which a maximum flow is required.
This operating mode is suitable e.g. for hot-water priority.
• Use the minimum curve mode in periods in which a minimum flow is required.
30
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
8
H
In systems requiring a constant flow, independently of pressure drop.
Examples:
• chillers for air-conditioning All
• heating surfaces
• cooling surfaces.
Q set Q
Constant level
H
In systems requiring a constant tank level, independently of the flow rate.
Examples: 2.2 - 11 kW, 2-pole
• process water tanks 3 - 7.5 kW, 4-pole
• boiler condensate tanks.
Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in
2.2 - 11 kW, 2-pole
parallel (two to four pumps) and without the use of external controllers. The "Assist" menu, "Multipump setup"
3 - 7.5 kW, 4-pole
pumps in a multipump system communicate with each other via the wireless
GENIair connection or the wired GENI connection.
Control options
Communication with TPE Series 1000 pumps is
possible via a central building management system,
remote control (Grundfos GO) or control panel.
The purpose of controlling the pump is to monitor and
control the pressure, temperature, flow rate and liquid
level of the system.
For further information on control options of the
pumps, see page 95.
31
9 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
9. TPE2
TPE2
Materials
32
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
9
Applications
TPE2
The pumps have integrated speed control for
automatic adaptation of performance to current
conditions.
The energy consumption is thus kept at a minimum.
The pumps can operate at any duty point within the
range between minimum and maximum speed.
HH
[m]
[m]
Maximum speed
0
3
0 QQ[m³/h]
[m h]
33
9 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
TPE2
Q
Constant curve
If an external controller is installed, the pump is able to change from one constant
curve to another, depending on the value of the external signal. H
The pump can also be set to operate according to the maximum or minimum curve,
like an uncontrolled pump:
• Use the maximum curve mode in periods in which a maximum flow is required. All
This operating mode is for instance suitable for hot-water priority.
• Use the minimum curve mode in periods in which a minimum flow is required.
This operating mode is for instance suitable for manual night setback instead of
automatic night setback.
Q
Constant flow rate
H
In systems requiring a constant flow, independently of pressure drop.
Examples:
• chillers for air-conditioning All
• heating surfaces
• cooling surfaces.
Q set Q
Constant level
H
In systems requiring a constant tank level, independently of the flow rate.
Examples:
All
• process water tanks
• boiler condensate tanks.
Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in
"Assist" menu
parallel (two to four pumps) and twin-head pumps without the use of external All
"Multipump setup"
controllers. The pumps in a multipump system communicate with each other via the
wireless GENIair connection or the wired GENI connection.
34
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
9
Multipump system Backup operation
TPE2
The multipump function enables the control of Backup operation is possible with two pumps of same
single-head pumps connected in parallel or twin-head size and type connected in parallel. Each pump
pumps without the use of external controllers. The requires a non-return valve in series with the pump.
pumps in a multipump system communicate with each One pump is operating continuously. The backup
other via the wireless GENIair connection or the wired pump is operated for a short time each day to prevent
GENI connection. seizing up. If the duty pump stops due to a fault, the
You set a multipump system via a selected pump, that backup pump starts automatically.
is the master pump which is the first selected pump. Pump system:
If you configure two pumps in the system with an • Twin-head pump.
outlet-pressure sensor, both pumps can function as • Two single-head pumps connected in parallel.
master pumps and take over the master pump function The pumps must be of the same type and size.
if the other fails. This provides additional redundancy Each pump requires a non-return valve in series
in the multipump system. with the pump.
You can connect all Grundfos pumps with a wireless
Cascade operation
GENIair connection to the multipump system.
Cascade operation ensures that the pump
The multipump functions are described in the following
performance is automatically adapted to the
sections.
consumption by switching pumps on or off. The system
Alternating operation thus runs as energy-efficiently as possible with a
Alternating operation functions as a duty-standby constant pressure and a limited number of pumps.
operating mode and is possible with two pumps of When a twin-head pump is running in
same size and type connected in parallel. The main constant-pressure control mode, the second pump
purpose of the function is to ensure an even amount of head starts at 90 % and stops at 50 % performance.
running hours and to ensure that the standby pump All pumps in operation will run at equal speed. Pump
takes over if the running pump stops due to an alarm. changeover is automatic and depends on energy,
Each pump requires a non-return valve in series with operating hours and fault.
the pump. Pump system:
You can choose between two alternating operation • Twin-head pump.
modes:
• Two to four single-head pumps connected in
• Alternating operation, time parallel. The pumps must be of the same type and
Pump changeover to the other is based on time. size. Each pump requires a non-return valve in
• Alternating operation, energy series with the pump.
Pump changeover to the other is based on energy Set the control mode to "Const. pressure" or "Const.
consumption. curve".
If the duty pump fails, the other pump takes over
automatically. Control options
Only one pump is operating at a time. The change from Communication with the pumps is possible via a
one pump to the other depends on time or energy. If a central building management system, Grundfos GO or
pump fails, the other pump will take over automatically. control panel.
Pump system: The purpose of controlling TPE2 pumps is to monitor
• Twin-head pump. and control the pressure, temperature, flow rate and
liquid level of the system.
• Two single-head pumps connected in parallel.
The pumps must be of the same type and size. For further information on control options of TPE2
Each pump requires a non-return valve in series pumps, see page 95.
with the pump.
35
10 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
10. TPE3
TPE3
Construction
The pumps have built-in differential-pressure and
temperature sensor.
The permanent-magnet motor has a built-in frequency
Carbon
Stationary seat (resin-impregnated),
silicon carbide
5 Stub shaft Stainless steel EN 1.4404
36
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
10
Applications
TPE3
The pumps have integrated speed control for
automatic adaptation of performance to current
conditions.
The energy consumption is thus kept at a minimum.
The pumps can operate at any duty point within the
range between minimum and maximum speed.
HH
[m]
[m]
Maximum speed
0
3
0 QQ[m³/h]
[m h]
"AUTO ADAPT"
Recommended for most heating systems, especially in systems with relatively large
pressure losses in the distribution pipes. See description under proportional H
pressure.
In replacement situations where the proportional-pressure duty point is unknown.
The duty point has to be within the "AUTOADAPT" operating range. During All
operation, the pump automatically makes the necessary adjustment to the actual
system characteristics.
This setting ensures minimum energy consumption and low noise level from the
valves, and therefore reduces operating costs and increases comfort.
Q
The FLOWADAPT control mode is a combination of AUTOADAPT and FLOWLIMIT.
This control mode is suitable for systems where a maximum flow limit, FLOWLIMIT,
is desired. The pump continuously monitors and adjusts the flow, thus ensuring that
the selected FLOWLIMIT is not exceeded. "FLOWADAPT"
Main pumps in boiler applications where a steady flow through the boiler is
required. No extra energy is used for pumping too much liquid into the system. H
In systems with mixing loops, the control mode can control the flow in each loop.
Benefits:
• Enough water for all loops at peak load conditions if each loop has been set to
All
the right maximum flow.
• The dimensioned flow for each zone (required heat energy) is determined by the
flow from the pump.
This value can be set precisely in the FLOWADAPT control mode without the use
of pump throttling valves.
• When the flow is set lower than the balancing valve setting, the pump ramps Q
down instead of losing energy by pumping against a balancing valve.
• Cooling surfaces in air-conditioning systems operate at high pressure and low
flow.
37
10 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
TPE3
Q
Constant temperature and constant
differential temperature
Q
Constant flow rate
H
In systems requiring a constant flow, independently of pressure drop.
Examples:
• chillers for air-conditioning All
• heating surfaces
• cooling surfaces.
Q set Q
38
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
10
TPE3
System application Select this control mode Pump type
Constant level
H
In systems requiring a constant tank level, independently of the flow rate.
Examples:
All
• process water tanks
• boiler condensate tanks.
Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in
"Assist" menu
parallel (two to four pumps) and twin-head pumps without the use of external All
"Multipump setup"
controllers. The pumps in a multipump system communicate with each other via the
wireless GENIair connection or the wired GENI connection.
39
10 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
The multipump function enables the control of two Backup operation is possible with two pumps of same
pumps connected in parallel without the use of size and type connected in parallel. Each pump
external controllers. The pumps in a multipump system requires a non-return valve in series with the pump.
communicate with each other via the wireless GENIair One pump is operating continuously. The backup
connection or the wired GENI connection. pump is operated for a short time each day to prevent
A multipump system is set via a selected pump, such seizing up. If the duty pump stops due to a fault, the
as the master pump which is the first selected pump. If backup pump starts automatically.
two pumps in the system are configured with an Pump system:
outlet-pressure sensor, both pumps can function as • Twin-head pump.
master pumps and take over the master pump function • Two single-head pumps connected in parallel.
if the other fails. This provides additional redundancy The pumps must be of the same type and size.
in the multipump system. Each pump requires a non-return valve in series
The multipump functions are described in the following with the pump.
sections.
Cascade operation
Alternating operation
Cascade operation ensures that the pump
Alternating operation functions as a duty-standby performance is automatically adapted to the
operating mode and is possible with two pumps of consumption by switching pumps on or off. The system
same size and type connected in parallel. The main thus runs as energy-efficiently as possible with a
purpose of the function is to ensure an even amount of constant pressure and a limited number of pumps.
running hours and to ensure that the standby pump When a twin-head pump is running in
takes over if the running pump stops due to an alarm. constant-pressure control mode, the second pump
Each pump requires a non-return valve in series with head starts at 90 % and stops at 50 % performance. All
the pump. pumps in operation run at equal speed. Pump
You can choose between two alternating operation changeover is automatic and depends on energy,
modes: operating hours and fault.
• Alternating operation, time Pump system:
Pump changeover to the other is based on time. • Twin-head pump.
• Alternating operation, energy • Two to four single-head pumps connected in
Pump changeover to the other is based on energy parallel.
consumption. The pumps must be of the same type and size.
If the duty pump fails, the other pump takes over Each pump requires a non-return valve in series
automatically. with the pump.
Only one pump is operating at a time. The change Set the control mode to "Const. pressure" or "Const.
from one pump to the other depends on time or curve".
energy. If a pump fails, the other pump will
automatically take over. Control options
Pump system: Communication with the pumps is possible via the
• Twin-head pump. control panel, Grundfos GO or a central building
• Two single-head pumps connected in parallel. management system.
The pumps must be of the same type and size. The purpose of controlling the pumps is to monitor and
Each pump requires a non-return valve in series control the pressure, temperature, flow rate of the
with the pump. system.
For further information on control options of the
pumps, see page 95.
40
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
11
Overview of functions
E-pump type
41
11 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Overview of functions
E-pump type
"Setpoint" ●
"Start/stop" ●
"Max. curve" ●
"Min. curve" ●
"Alarm reset" ●
"Enable radio communication" ●
Stop Status readings via standard control panel
"Setpoint" ●
"Operating indication" ●
"Fault indication" ●
"Operating mode: MIN, MAX, STOP" ●
"Setpoint" ●
"Start/stop" ●
"Max. curve" ●
"Min. curve" ●
"Alarm reset" ●
"Setpoint" ●
"Operating indication" ●
"Fault indication" ●
"Operating mode: MIN, MAX, STOP" ●
● Available.
1)
The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.
42
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
11
Overview of functions
E-pump type
"Setpoint" ● ● ● ●
"Operating mode" ● ● ● ●
"Control mode" ● ● ● ●
"Proportional-pressure setup" ●
"FLOWLIMIT" ●
"Automatic night setback" ●
"Temperature influence" ●
"Buttons on product" ● ● ● ●
"Controller" ● ● ● ●
"Operating range" ● ● ● ●
"Ramps" ● ● ●
"Number" ● ● ● ●
"Radio communication" ● ● ●
"Sensor type" ●
"Analog input 1" ● ● ●
"Analog input 2" ● ● ●
"Analog input 3" ● ● ●
"Built-in Grundfos sensor" ●
"Pt100/1000 input 1" ● ● ●
"Pt100/1000 input 2" ● ● ●
"Digital input 1" ● ● ●
"Digital input 2" ● ● ● ●
"Digital in/output 3" ● ● ●
"Digital in/output 4" ● ● ●
"Pulse flow meter" ● ● ●
"Predefined setpoint" ● ● ●
"Analog output" ● ● ●
"External setpoint funct." ● ● ● ●
"Signal relay 1" ● ● ● ●
"Signal relay 2" ● ● ● ●
"Limit 1 exceeded" ● ● ●
"Limit 2 exceeded" ● ● ●
"Standstill heating" ● ● ● ●
"Motor bearing monitoring" ● ● ● ●
"Service" ● ● ●
"Date and time" ● ● ●
"Store settings" ● ● ● ●
"Recall settings" ● ● ● ●
"Undo" ● ● ● ●
"Pump name" ● ● ●
"Connection code" ● ● ●
"Unit configuration" ● ● ● ●
● Available.
1)
The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.
43
11 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Overview of functions
E-pump type
"Resulting setpoint" ● ● ● ●
"Actual controlled value" ● ● ● ●
"Motor speed (rpm, %)" ● ● ● ●
"Power consumption" ● ● ● ●
"Energy consumption" ● ● ● ●
"Acc. flow, specific energy" ● ● ●
"Operating hours" ● ● ● ●
"Motor current" ● ● ● ●
"Number of starts" ● ● ● ●
"Liquid temperature" ●
"Pt100/1000 input 1" ● ● ●
"Pt100/1000 input 2" ● ● ●
"Analog output" ● ● ●
"Analog input 1" ● ● ●
"Analog input 2" ● ● ●
"Analog input 3" ● ● ●
"Digital input 1" ● ● ●
"Digital input 2" ● ● ● ●
"Digital in/output 3" ● ● ●
"Digital in/output 4" ● ● ●
"Motor bearing service" ● ● ● ●
"Fitted modules" ● ● ●
"Trend data" ●
"Heat energy monitor" ●
"Setpoint" ● ● ● ●
"Start/stop" ● ● ● ●
"Max. curve" ● ● ● ●
"Min. curve" ● ● ● ●
"Constant pressure", "proportional pressure" or
● ● ● ●
"constant curve"
"Setpoint" ● ● ● ●
"Operating indication" ● ● ● ●
"Pump status" ● ● ● ●
"Setpoint" ● ● ● ●
"Predefined setpoint" ● ● ●
"Start/stop" ● ● ● ●
"Min./max. curve via digital input" ● ● ● ●
"Alarm resetting" ● ● ●
● Available.
1)The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.
44
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
11
Overview of functions
E-pump type
45
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
46
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Setpoint setting Example: Pump set to maximum curve.
Q
Fig. 25 Minimum curve duty
47
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Reset a fault indication in one of the following ways: Note: You can only set the setpoint when the operating
• Via the digital input if it has been set to "Alarm mode is "Normal".
resetting". Set the desired setpoint by pressing or .
• Briefly press or on the pump. This will not The light fields on the control panel indicates the
change the setting of the pump. setpoint set.
You cannot reset a fault indication by pressing
or if the buttons have been locked. Control mode "Differential-pressure control"
• Switch off the power supply until the indicator lights Example
are off. Figure 27 shows that light fields 5 and 6 are activated,
• Switch the external start/stop input off and then on indicating a desired setpoint of 3.4 m. The sensor
again. measuring range is 0 to 6 m. The setting range is equal
• With Grundfos GO. to the sensor measuring range. See sensor
nameplate.
Control panel for TPE Series 1000 pumps,
15-22 kW, 2-pole and 11 - 18.5 kW, 4-pole
Fitted as
Pump variant Option
standard
TPE3, TPE3 D - -
TPE2, TPE2 D - -
The control panel incorporates the following buttons Fig. 27 Setpoint set to 3.4 m, control mode
and indicator lights: "differential-pressure control"
• buttons, and , for setpoint setting
Control mode "Constant curve"
• light fields, yellow, for setpoint indication
• indicator lights, green (operation) and red (fault). Example
In this control mode, the pump performance is set
within the range from minimum to maximum curve.
Buttons See fig. 28.
Light fields
H
TM05 8590 2613
Indicator lights
TM00 7746 1304
Q
Fig. 26 Control panel for TPE Series 1000 pumps, 15-22
kW, 2-pole and 11 - 18.5 kW, 4-pole
48
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Setting to maximum curve duty
H
6 3
49
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
"Home" display
User interfaces for TPE pumps
1 2 3 4
Normal
4.90 bar
Startup guide
The pump incorporates a startup guide which is started
at the first startup. See "Run start-up guide" on page
83. After the startup guide, the main menus appear in
the display.
50
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Menu overview for advanced control
TPE2, TPE2 D
Main menus Status
Multipump system2)
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
TPE Series 1000
TPE3, TPE3 D
TPE2, TPE2 D
"Multipump system" ●
Home
"System operating status" ●
"System performance" ●
"System input power and energy" ●
Multipump system 2)
2.2 - 11 kW, 2-pole
1)
TPE2, TPE2 D
Status 2) Pumps above 11 kW, 2-pole and 7.5 kW, 4-pole have no multipump
function.
51
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
User interfaces for TPE pumps
Multipump system 2)
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
TPE Series 1000
TPE3, TPE3 D
TPE2, TPE2 D
Settings Section Page
52
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
TPE2, TPE2 D
Assist Section Page
53
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Grundfos GO Communication
User interfaces for TPE pumps
The pump is designed for wireless radio or infrared When Grundfos GO initiates communication with the
communication with Grundfos GO. pump, the indicator light in the middle of Grundfos Eye
flashes green. See Priority of settings on page 89.
Grundfos GO enables setting of functions and gives
access to status overviews, technical product Furthermore, on pumps fitted with an advanced control
information and actual operating parameters. panel a text appears in the display saying that a
wireless device is trying to establish connection. Press
Grundfos GO offers the following mobile interfaces, MI.
on the pump in order to establish connection with
Grundfos GO or press to reject connection.
Establish communication using one of these
communication types:
• radio communication
• infrared communication.
1 Radio communication
Radio communication can take place at distances up
2 to 30 metres. The first time Grundfos GO
+ communicates with the pump, you must enable
communication by pressing or on the pump
+ control panel. Later when communication takes place,
TM06 6256 0916
Pos. Description
Grundfos MI 204:
Add-on module enabling radio or infrared communication.
You can use MI 204 in conjunction with an Apple iPhone or
1 iPod with Lightning connector, for example fifth generation
or later iPhone or iPod.
MI 204 is also available together with an Apple iPod touch
and a cover.
Grundfos MI 301:
Separate module enabling radio or infrared communication.
2
You can use the module in conjunction with an Android or
iOS-based smart device with Bluetooth connection.
54
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Menu overview for Grundfos GO
Multipump system 1)
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
TPE2, TPE2 D
Dashboard
● ● ●
Multipump system 1)
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
TPE2, TPE3 D
Status Section Page
"System mode" ●
"Resulting setpoint" ● ● ●
"Resulting system setpoint" ●
"Actual setpoint" ●
"External setpoint" ●
"Actual controlled value" ● ● ● ●
"Sensor value" ●
"Motor speed (rpm, %)" ● ● ● ●
"Power consumption" ● ● ● ●
"Power consumption system" ●
"Energy consumption" ● ● ● ●
"Energy consumption system" ●
"Acc. flow, specific energy" ● ● ● ●
"Operating hours" ● ● ● ●
"Motor current" ● ● ● ● ●
"Number of starts" ● ● ● ● ●
"Liquid temperature" ●
"Analog input 1" ● ● ●
"Analog input 2" ● ● ●
"Analog input 3" ● ● ●
"Pt100/1000 input 1" ● ● ●
"Pt100/1000 input 2" ● ● ●
"Analog output" ● ● ●
"Digital input 1" ● ● ●
"Digital input 2" ● ● ● ●
"Digital in/output 3" ● ● ●
"Digital in/output 4" ● ● ●
"Motor bearing service" ● ● ● ● ●
"Fitted modules" ● ● ● ●
"Trend data" ●
"Heat energy monitor" ●
"Controlled from" ●
"Pump1" ●
"Pump2" ●
"Pump3" ●
"Pump4" ●
1)
Pumps above 11 kW, 2-pole and 7.5 kW, 4-pole have no multipump function.
55
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
User interfaces for TPE pumps
Multipump system 1)
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
TPE2, TPE2 D
Settings Section Page
"Setpoint" ● ● ● ● ● "Setpoint" 58
"Operating mode" ● ● ● ● ● "Operating mode" 59
"Set user-defined speed" ● ● ● ● ● "Set user-defined speed" 59
"Control mode" ● ● ● ● ● "Control mode" 59
"Proportional-pressure setup" ● "Proportional-pressure setup" 66
"Flow limit" ● "FLOWLIMIT" 66
"Automatic night setback" ● "Automatic night setback" 67
"Temperature influence" ● "Temperature influence" 77
"Buttons on product" ("Enable/disable
"Buttons on product" ● ● ● ● ● 81
settings")
"Controller" ● ● ● ● ● "Controller" ("Controller settings") 73
"Operating range" ● ● ● ● ● "Operating range" 74
"Ramps" ● ● ● "Ramps" 79
"Number" ● ● ● ● "Number" ("Pump number") 80
"Radio communication" ("Enable/disable
"Radio communication" ● ● ● 80
radio comm.")
"Sensor type" ● "Sensor type" 67
"Analog input 1" ● ● ●
"Analog input 2" ● ● ● "Analog inputs" 67
"Analog input 3" ● ● ●
"Built-in Grundfos sensor" ● "Built-in Grundfos sensor" 68
"Pt100/1000 input 1" ● ● ●
"Pt100/1000 inputs" 69
"Pt100/1000 input 2" ● ● ●
"Digital input 1" ● ● ●
"Digital inputs" 69
"Digital input 2" ● ● ● ●
"Digital in/output 3" ● ● ●
"Digital inputs/outputs" 71
"Digital in/output 4" ● ● ●
"Pulse flowmeter" ● ● ●
"Predefined setpoint" ● ● ● ● "Predefined setpoints" 77
"Analog output" ● ● ● "Analog output" 72
"External setpoint funct." ● ● ● ● "External setpoint influence" 75
"Signal relay 1" ● ● ● ●
"Signal relays 1 and 2" ("Relay outputs") 72
"Signal relay 2" ● ● ● ●
"Limit 1 exceeded " ● ● ● ●
"Limit-exceeded function" 78
"Limit 2 exceeded " ● ● ● ●
"Alternating operation, time" ●
"Time for pump change over" ●
"Standstill heating" ● ● ● ● "Standstill heating" 79
"Motor bearing monitoring" ● ● ● ● "Motor bearing monitoring" 79
"Service" ● ● ● "Service" 80
"Date and time" ● ● ● ● "Date and time" 81
"Store settings" ● ● ● ● "Store settings" ("Store actual settings") 82
"Recall settings" ● ● ● ● "Recall settings" ("Recall stored settings") 82
"Undo" ● ● ● ● ● "Undo" 82
"Pump name" ● ● ● ● "Pump name" 82
"Connection code" ● ● ● ● "Connection code" 83
"Unit configuration" ● ● ● ● "Unit configuration" ("Units") 81
56
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
TPE2, TPE2 D
Alarms and warnings Section Page
1) Pumps above 11 kW, 2-pole and 7.5 kW, 4-pole have no multipump function.
Multipump system 1)
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
TPE2, TPE2 D
Assist Section Page
57
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
kWh
t
F
TM06 1182 1814
t
R
58
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Operating mode" "Set manual speed"
Possible operating modes: This menu is only available in the advanced control
• "Normal" panel. With Grundfos GO, you set the speed via the
The pump runs according to the selected control "Setpoint" menu.
mode. You can set the pump speed in % of the maximum
• "Stop" speed. When you have set the operating mode to
The pump stops. "Manual", the pump starts running at the set speed.
• "Min." The speed can then be changed manually via
Use the minimum curve mode in periods in which a Grundfos GO or via the advanced control panel.
minimum flow is required.
This operating mode is for instance suitable for
"Set user-defined speed"
manual night setback if you do not want to use You can set the motor speed in % of the maximum
automatic night setback. speed. When you have set the operating mode to
• "Max." "User-defined speed", the motor runs at the set speed.
Use the maximum curve mode in periods in which a
maximum flow is required. "Control mode"
This operating mode is for instance suitable for
Pump variant "Control mode"
hot-water priority.
TPE3, TPE3 D ●
• "Manual" TPE2, TPE2 D ●
The pump is operating at a manually set speed. 2.2 - 11 kW, 2-pole
●
In "Manual" the setpoint via bus is overruled. See TPE Series 1000
1.1 - 7.5 kW, 4-pole
"Set manual speed" on page 59. 15-22 kW, 2-pole
●
11 - 18.5 kW, 4-pole
• "User-defined speed"
The motor is operating at a speed set by the user. Note: Not all control modes are available for all pump
See section "Set user-defined speed" on page 59. variants.
All operating modes are illustrated in the fig. 35. Possible control modes:
• "AUTOADAPT"
H
Max.
• "FLOWADAPT"
Normal • "Prop. press." (proportional pressure)
• "Const. pressure" (constant pressure)
Normal • "Const. temp." (constant temperature)
Manual
• "Con. diff. press." (constant differential pressure)
TM06 4024 1515
Min.
• "Con. diff. temp." (constant differential temperature)
• "Const. flow rate" (constant flow rate)
Stop
Q
• "Const. level" (constant level)
• "Const. other val." (constant other value)
Fig. 35 Operating modes
• "Const. curve" (constant curve).
Factory setting You can change the setpoint for all control modes,
See section 13. Factory settings of E-pumps. except AUTOADAPT and FLOWADAPT, in the "Setpoint"
submenu under "Settings" when you have selected the
desired control mode.
Factory setting
See section 13. Factory settings of E-pumps.
59
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
"AUTOADAPT" "FLOWADAPT"
User interfaces for TPE pumps
The AUTOADAPT control mode continuously adapts the When you select FLOWADAPT, the pump runs
pump performance according to the actual system AUTOADAPT and ensures that the flow never exceeds
characteristic. the entered FLOWLIMIT value.
Manual setting of the setpoint is not possible. The setting range for FLOWLIMIT is 25 to 90 % of the
Qmax of the pump.
H The factory setting of the FLOWLIMIT is the flow where
the AUTOADAPT factory setting meets the maximum
curve. See fig. 37.
Hfac Hset1
H 25 % 90 % Q
Qmax
max
A1
Setting range
TM05 7910 1613
Hauto_min Hset2
A3 A2
HHfac
fac
Q
Fig. 36 AUTOADAPT HHauto_min
auto_min
60
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Proportional pressure" "Constant pressure"
H
Q
Fig. 40 "Constant pressure"
2 Examples
• One external pressure sensor.
Q
Fig. 38 "Proportional pressure"
Example
p
• Factory-fitted differential-pressure sensor.
p
p
Fig. 41 "Constant pressure"
61
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
This control mode ensures a constant temperature. The pump maintains a constant differential pressure,
Constant temperature is a comfort control mode that independently of the flow in the system. See fig. 44.
you can use in domestic hot-water systems to control This control mode is primarily suitable for systems with
the flow to maintain a fixed temperature in the system. relatively small pressure losses.
See fig. 42.
H
H
Q
Q Fig. 44 "Constant differential pressure"
Fig. 42 "Constant temperature"
This control mode requires either an internal or
This control mode requires either an external external differential-pressure sensor or two external
temperature sensor as shown in the examples below: pressure sensors. See the examples below.
Examples
• Factory-fitted temperature sensor. Only TPE3,
TPE3 D.
Controller settings
For recommended controller settings, see "Controller"
("Controller settings") on page 73.
62
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Constant differential temperature"
p △t
p
Controller settings
For recommended controller settings, see "Controller"
("Controller settings") on page 73.
63
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Examples
• Factory-fitted temperature sensor and an external Pump variant "Constant flow rate"
temperature sensor. Only TPE3, TPE3 D. TPE3, TPE3 D ●
TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole
●
3 - 7.5 kW, 4-pole
t TPE Series 1000
15-22 kW, 2-pole
●
t 11 - 18.5 kW, 4-pole
Q
Q set
t
Fig. 48 "Constant flow rate"
t
This control mode requires an external flow sensor.
t
See the example below.
• One external differential-temperature sensor.
Example
The pump uses the input from the sensor to control
• One external flow sensor.
the differential temperature.
You can set the sensor manually or by using the
"Assist" menu. See "Assisted pump setup" on page Q
84.
Fig. 49 Constant flow rate
Controller settings
t For recommended controller settings, see "Controller"
("Controller settings") on page 73.
Controller settings
For recommended controller settings, see "Controller"
("Controller settings") on page 73.
64
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Constant level"
Controller settings
Q For recommended controller settings, see "Controller"
Fig. 50 "Constant level" ("Controller settings") on page 73.
This control mode requires an external level sensor. "Constant other value"
The pump can control the level in a tank in two ways: "Constant other
Pump variant
• As an emptying function where the pump draws the value"
liquid from the tank. TPE3, TPE3 D ●
TPE2, TPE2 D ●
• As a filling function where the pump pumps the
2.2 - 11 kW, 2-pole
liquid into the tank. 3 - 7.5 kW, 4-pole
●
TPE Series 1000
See fig. 51. 15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole
The type of level control function depends on the
setting of the built-in controller. See "Controller" Any other value is kept constant.
("Controller settings") on page 73. Use this control mode if you want to control a value
which is not available in the "Control mode" menu.
Connect a sensor measuring the controlled value to
one of the analog inputs of the pump. The controlled
value will be shown in percentage of sensor range.
65
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
"FLOWLIMIT"
Pump variant "FLOWLIMIT"
TPE3, TPE3 D ●
TPE2, TPE2 D -
2.2 - 11 kW, 2-pole
TM05 7957 1713
-
3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole
Q FLOWLIMIT
Fig. 52 "Constant curve" • Enable FLOWLIMIT function.
• Set FLOWLIMIT.
Depending on the system characteristic and the duty
point, the 100 % setting may be slightly smaller than H 25 % 90 % Q max
the actual maximum curve of the pump even though
the display shows 100 %. This is due to the power and Setting range
pressure limitations built into the pump. The deviation
varies according to pump type and pressure loss in the
pipes.
H [%]
66
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Automatic night setback" "Analog inputs"
Once you have enabled automatic night setback, the Function Terminals*
pump automatically changes between normal duty and "Analog input 1, setup" 4
night setback, duty at low performance. "Analog input 2, setup" 7
"Analog input 3, setup" 14
Changeover between normal duty and night setback
depends on the flow-pipe temperature. * See Connection terminals, advanced functional module, FM 300 on
page 115.
The pump automatically changes over to night setback
when the built-in sensor registers a flow-pipe Set the analog input for a feedback sensor via the
temperature drop of more than 10 to 15 °C within "Assisted pump" setup menu. See "Assisted pump
approximately two hours. The temperature drop must setup" on page 84.
be at least 0.1 °C/min. If you want to set an analog input for other purposes,
Changeover to normal duty takes place without a time you can do this manually.
lag when the temperature has increased by You can set the analog inputs via the "Setup, analog
approximately 10 °C. input" menu. See "Setup, analog input" on page 85.
Note: You cannot enable automatic night setback If you perform the manual setting via Grundfos GO,
when the pump is in constant-curve mode. you need to enter the menu for the analog input under
the "Settings" menu.
"Sensor type"
Function
Pump variant "Sensor type" You can set the analog inputs to these functions:
TPE3, TPE3 D - • "Not active"
TPE2, TPE2 D -
• "Feedback sensor"
2.2 - 11 kW, 2-pole
-
3 - 7.5 kW, 4-pole • "Ext. setpoint infl."
TPE Series 1000
15-22 kW, 2-pole
● See "External setpoint influence" on page 75.
11 - 18.5 kW, 4-pole
• "Other function".
The setting of the sensor is only relevant in the case of
controlled operation.
Select among the following values:
• Sensor output signal
0-10 V
0-20 mA
4-20 mA.
• Unit of measurement of sensor:
bar, mbar, m, kPa, psi, ft, m3/h, m3/s, l/s, gpm, °C,
°F, %.
• Sensor measuring range.
67
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Select one of the parameters, that is the parameter to In order to measure the difference of a parameter
be measured in the system by the sensor connected to between two points, set the corresponding sensors as
the actual analog input. See fig. 55. follows:
68
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Pt100/1000 inputs" "Digital inputs"
Set the Pt100/1000 input for a feedback sensor via the * See Connection terminals, advanced functional module, FM 300 on
Assisted pump setup menu. See "Assisted pump page 115.
setup" on page 84. To set up a digital input, make the settings below.
If you want to set a Pt100/1000 input for other
Function
purposes, you can do this manually.
You can set the analog inputs via the "Setup, analog Select one of these functions:
input" menu. See "Setup, analog input" on page 85. • "Not active"
If you perform the manual setting via Grundfos GO, When set to "Not active", the input has no function.
you need to enter the menu for the Pt100/1000 input • "External stop"
under the Settings menu. When the input is deactivated, open circuit, the
Function pump stops.
You can set the Pt100/1000 inputs to these functions: • "Min." (minimum speed)
When the input is activated, the pump runs at the
• "Not active"
set minimum speed.
• "Feedback sensor"
• "Max." (maximum speed)
• "Ext. setpoint infl." When the input is activated, the pump runs at the
See "External setpoint influence" on page 75. set maximum speed.
• "Other function". • "User-defined speed"
Measured parameter When the input is activated, the motor runs at a
speed set by the user.
Select one of the parameters, such as the parameter
to be measured in the system by the Pt100/1000 • "External fault"
sensor connected to the actual Pt100/1000 input. See When the input is activated, a timer starts. If the
fig. 56. input is activated for more than 5 seconds, the
pump stops and a fault is indicated. This function
1 2 depends on input from external equipment.
TM06 4012 1515
TT TT
• "Alarm resetting"
4 3 When the input is activated, a possible fault
DTT TT indication is reset.
Parameter Pos.
"Liquid temp." 1
"Temperature 1" 2
"Temperature 2" 3
"Ambient temp." Not shown
Measuring range
-50 to +204 °C.
Factory setting
See section 13. Factory settings of E-pumps.
69
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
When this function has been selected, lack of inlet Select the mode. See fig. 57.
pressure or water shortage can be detected.
• "Not active"
When lack of inlet pressure or water shortage, dry
running, is detected, the pump stops. The pump • active with interrupt, mode A
cannot restart as long as the input is activated. • active without interrupt, mode B
This requires the use of an accessory, such as • active with after-run, mode C.
these: Select the duration time, T2.
– a pressure switch installed on the inlet side of the It is the time which, together with the mode,
pump determines how long the selected function is active.
– a float switch installed on the inlet side of the Range: 0 to 15,000 seconds.
pump.
• "Accumulated flow" T input
T input>>T1
T1 ++T2
T2 T input < T1
T input < T1++ T2
T2
See "Predefined setpoints" on page 77. Fig. 57 Duration timer function of digital inputs
The priority of the selected functions in relation to each
other appears from section Priority of settings on page Factory setting
89. See section 13. Factory settings of E-pumps.
A stop command always has the highest priority. Motors from 15-22 kW, 2-pole and 11 - 18.5 kW,
Activation delay 4-pole
You can set the digital input of the pump can be set to
Pump variant Activation delay different functions. Select one of the following
TPE3, TPE3 D - functions:
TPE2, TPE 2 D ●
• "Min." (minimum curve)
2.2 - 11 kW, 2-pole
●
3 - 7.5 kW, 4-pole • "Max." (maximum curve).
TPE Series 1000
15-22 kW, 2-pole You activate the selected function by closing the
-
11 - 18.5 kW, 4-pole
contact between terminals 1 and 9.
Select the activation delay, T1. "Min.":
It is the time between the digital signal and the When the input is activated, the pump operates
activation of the selected function. according to the minimum curve.
Range: 0 to 6000 seconds. "Max.":
When the input is activated, the pump operates
according to the maximum curve.
70
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Digital inputs/outputs" Possible functions, digital input or output 4
71
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Factory setting
See section 13. Factory settings of E-pumps.
72
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
• "Motor load" "Controller" ("Controller settings")
"Flow rate"
Signal range [%] p p
[V, mA]
0 100 200
"0-10 V" 0V 5V 10 V L1
"0-20 mA" 0 mA 10 mA 20 mA
ǻS
"4-20 mA" 4 mA 12 mA 20 mA
L1 < 5 m: 0.5
The reading is a percentage of the range between 0 0.5 L1 > 5 m: 3
and 200 % of the nominal flow. L1 L1 > 10 m: 5
Factory setting
ǻS
See section 13. Factory settings of E-pumps.
73
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Rules of thumb
User interfaces for TPE pumps
Kp
Temperature control Ti If the controller is too slow-reacting, increase the gain.
Heating Cooling
system 1) system 2) If the controller is hunting or unstable, dampen the
system by reducing the gain or increasing the integral
time.
0.5 -0.5 10 + 5L2 Factory setting
t
See section 13. Factory settings of E-pumps.
L2
L2
"Operating range"
t 0.5 -0.5 30 + 5L2 Pump variant "Operating range"
TPE3, TPE3 D ●
TPE2, TPE2 D ●
1) 2.2 - 11 kW, 2-pole
In heating systems, an increase in pump performance results in a ●
3 - 7.5 kW, 4-pole
rise in temperature at the sensor. TPE Series 1000
2) 15-22 kW, 2-pole
In cooling systems, an increase in pump performance results in a ●
11 - 18.5 kW, 4-pole
drop in temperature at the sensor.
L2: Distance in metres between heat exchanger and Set the operating range as follows:
sensor. • Set the minimum speed within the range from fixed
minimum speed to user-set maximum speed.
Differential-temperature control Kp Ti
• Set the maximum speed within the range from
user-set minimum speed to fixed maximum speed.
The range between the user-set minimum and
t
maximum speeds is the operating range.
L2 Note: Speeds below 25 % may result in noise from the
-0.5 10 + 5L2 shaft seal.
t
100 % Fixed maximum speed
t
t
L2 67 % User-set maximum speed
p 0.1 0.5
Level control Kp Ti
L
-2.5 100
2.5 100
74
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"External setpoint influence" Example with constant pressure with linear
TPE2, TPE3 pumps and TPE Series 1000 2.2 - 11 Sensor max.
kW, 2-pole and 3 - 7.5 kW, 4-pole pumps
You can influence the setpoint by an external signal, "Setpoint" 2 100
either via one of the analog inputs or, if an advanced
functional module is fitted, via one of the Pt100/1000 Actual 1.2
setpoint
inputs.
Note: Before you can enable the "External setpoint Sensor min. 0 0
Actual 100 % External
function", set one of the analog inputs or Pt100/1000 0
User-set min. 25
speed
0
0 Actual 100 % External
TM06 4525 2515
Factory setting
See section 13. Factory settings of E-pumps.
75
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
TPE Series
1000
0
0 20 100 % External
3.5 V input
TPE3
TPE2
0.5
0 5V
"Not active" ● ● ● ● 0 10 V
0 20 mA
"Linear function" ● ● ● ● 4 20 mA
"Linear with Stop" ● ● ● - -50 204 C
"Influence table" ● ● ● -
100
0
0 100 % External
input
0.5 3.5 V
TM06 4166 1615
0 5V
0 10 V 0
0 20 mA 0 100 % External
4 20 mA 0.5 3.5 V input
TM06 4170 1615
-50 204 C 0 5V
0 10 V
Fig. 63 "Linear function" 0 20 mA
4 20 mA
-50 204 C
76
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Predefined setpoints" "Temperature influence"
You can set and activate seven predefined setpoints When this function is enabled in proportional- or
by combining the input signals to digital inputs 2, 3 and constant-pressure control mode, the setpoint for head
4 as shown in the table below. is reduced according to the liquid temperature.
Set the digital inputs 2, 3 and 4 to "Predefined You can set the temperature influence to function at
setpoints" if all seven predefined setpoints are to be liquid temperatures below 80 or 50 °C. These
used. You can also set one or two of the digital inputs temperature limits are called Tmax. The setpoint is
to "Predefined setpoints" but this will limit the number reduced in relation to the head set which is equal to
of predefined setpoints available. 100 % according to the characteristics below.
"Digital inputs" H H
"Setpoint"
2 3 4
0 0 0 Normal setpoint or stop
1 0 0 Predefined setpoint 1 100 %
0 1 0 Predefined setpoint 2 Hactual
H actual
1 1 0 Predefined setpoint 3
0 0 1 Predefined setpoint 4
1
0 Setpoint 1
• Systems with variable flows, for example two-pipe
heating systems, in which the enabling of the
Normal
setpoint temperature influence function will ensure a further
Stop reduction of the pump performance in periods with
Fig. 66 Principle sketch showing how predefined setpoints small heating demands and consequently a reduced
function flow-pipe temperature.
If all digital inputs are open, the pump either stops or • Systems with almost constant flows, for example
runs at the normal setpoint. Set the desired action with one-pipe heating systems and underfloor heating
Grundfos GO or with the advanced control panel. systems, in which variable heating demands cannot
be registered as changes in the head as it is the
Factory setting case with two-pipe heating systems. In such
See section 13. Factory settings of E-pumps. systems, you can only adjust the pump performance
by enabling the temperature influence function.
77
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
In systems with a dimensioned flow-pipe temperature If the value exceeds a limit, you can define an action.
of: You can select the following actions:
• up to and including 55 °C, select Tmax. equal to 50 • "No action"
°C The pump remains in its current state. Use this
• above 55 °C, select Tmax. equal to 80 °C. setting if you only want to have a relay output when
Note: You cannot use the temperature function in the limit is reached. See "Signal relays 1 and 2"
air-conditioning and cooling systems. ("Relay outputs") on page 72.
• "Warning/alarm"
Factory setting There is a warning.
See section 13. Factory settings of E-pumps. • "Stop"
The pump stops.
"Limit-exceeded function"
• "Min."
"Limit-exceeded The pump reduces speed to minimum.
Pump variant
function" • "Max."
TPE3, TPE3 D ● The pump increases speed to maximum.
TPE2, TPE2 D ●
• "User-defined speed"
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
● The pump runs at a speed set by the user.
TPE Series 1000
15-22 kW, 2-pole "Detection delay"
-
11 - 18.5 kW, 4-pole
You can set a detection delay which ensures that the
This function can monitor a measured parameter or monitored parameter stays above or below a set limit
one of the internal values such as speed, motor load or in a set time before the function is activated.
motor current. If a set limit is reached, a selected
action can take place. You can set two limit-exceeded "Resetting delay"
functions meaning that you can monitor two The resetting delay is the time from which the
parameters or two limits of the same parameter measured parameter differs from the set limit including
simultaneously. the set hysteresis band and until the function is reset.
The function requires setting of the following: Example
Measured The function is to monitor the outlet pressure of a
Here you set the measured parameter to be monitored. pump. If the pressure is below 5 bar for more than 5
seconds, a warning must be given. If the outlet
"Limit"
pressure is above 7 bar for more than 8 seconds, you
Here you set the limit which activates the function. must reset the warning.
"Hysteresis band"
1
Here you set the hysteresis band.
"Limit exceeded when"
3
Here you can set if you want the function to be 2
The function is activated if the measured parameter Fig. 68 Limit exceeded, example
drops below the set limit.
Pos. Setting parameter Setting
1 Measured Outlet pressure
2 "Limit" 5 bar
3 "Hysteresis band" 2 bar
4 "Limit exceeded when" Below limit
5 "Detection delay" 5 seconds
6 "Resetting delay" 8 seconds
A Limit-exceeded function active -
- Action Warning
Factory setting
See section 13. Factory settings of E-pumps.
78
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Special functions "Standstill heating"
Factory setting
See section 13. Factory settings of E-pumps.
79
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
maintenance")
Pump variant "Service"
The following applies only for 11 kW motors.
TPE3, TPE3 D ●
When the bearing monitoring function is active, the
TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole
controller gives a warning when the motor bearings are
● due to be relubricated.
3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole When you have relubricated the motor bearings, press
-
11 - 18.5 kW, 4-pole
[Bearings relubricated].
"Motor bearing monitoring" must be activated in order The factory-set interval between relubrications is
for the motor to indicate that bearings must be stated on the bearing nameplate which is placed on
replaced or relubricated. See "Motor bearing the motor. The relubrication interval can be changed
monitoring" on page 79. by a Grundfos service technician.
For motors of 7.5 kW and below, it is not possible to It is possible to relubricate the bearings five times
relubricate the bearings. according to the preset interval. When the preset
Bearings on motors of 11 kW and above can be interval has been reached after the fifth relubrication, a
relubricated. warning will be given to replace the bearings.
"Time until next service" ("Motor bearing service")
Communication
This display shows when to replace or relubricate the
motor bearings. The controller monitors the operating "Number" ("Pump number")
pattern of the motor and calculates the period between
Pump variant "Pump number"
bearing replacements or relubrications.
TPE3, TPE3 D ●
Displayable values: TPE2, TPE2 D ●
• "in 2 years" 2.2 - 11 kW, 2-pole
●
3 - 7.5 kW, 4-pole
• "in 1 year" TPE Series 1000
15-22 kW, 2-pole
●
• "in 6 months" 11 - 18.5 kW, 4-pole
• "in 3 months" You can allocate a unique number to the pump. This
• "in 1 month" makes it possible to distinguish between pumps in
• "in 1 week" connection with bus communication.
• "Now" Factory setting
"Bearing replacements" See section 13. Factory settings of E-pumps.
This display shows the number of bearing "Radio communication" ("Enable/disable radio
replacements that have been done during the lifetime comm.")
of the motor.
"Radio
"Bearings replaced" ("Motor bearing Pump variant
communication"
maintenance") TPE3, TPE3 D ●
When the bearing monitoring function is active, the TPE2, TPE2 D ●
controller gives a warning when the motor bearings are 2.2 - 11 kW, 2-pole
●
3 - 7.5 kW, 4-pole
to be replaced. TPE Series 1000
15-22 kW, 2-pole
-
When you have replaced the motor bearings, confirm 11 - 18.5 kW, 4-pole
this action by pressing [Bearings replaced].
You can set the radio communication to either enabled
"Bearing relubrications" or disabled. You can use this function in areas where
The following applies only for 11 kW motors. radio communication is not allowed.
This display shows the number of bearing IR communication remains active.
relubrications that have been done since the last Factory setting
bearing replacement.
See section 13. Factory settings of E-pumps.
80
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
General settings "Buttons on product" ("Enable/disable settings")
81
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
82
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Connection code" "Run start-up guide"
This menu is only available in Grundfos GO. This menu is only available in the advanced control
You can set a connection code to avoid having to press panel.
the connection button each time and to restrict remote The startup guide automatically starts when you start
access to the product. the pump for the first time.
Setting the code in the product using Grundfos GO You can always run the startup guide later via this
menu.
1. Connect Grundfos GO to the product.
The startup guide guides you through the general
2. In the product dashboard, select "Settings".
settings of the pump.
3. Choose "Connection code".
• "Language". See "Language" on page 81.
4. Enter the wanted code and press [OK].
• "Select date format".*
The code must be a character string, ASCII. You
See "Date and time" on page 81.
can always modify the code. The old code is not
needed. • "Set date".*
See "Date and time" on page 81.
Setting the code in Grundfos GO • "Select time format".*
You can set a default connection code in Grundfos GO See "Date and time" on page 81.
so that it automatically attempts to connect to the • "Set time".*
selected product via this code. See "Date and time" on page 81.
When you select a product with the same connection • "Setting of pump"
code in Grundfos GO, Grundfos GO automatically
– "Go to Home"
connects to the product and you do not have to press
the connection button on the module. – "Run with Constant curve"/"Run with Constant
pressure".
Set the default code in Grundfos GO in this way:
See "Control mode" on page 59
1. In the main menu, under "General", select
– "Go to Assisted pump setup".
"Settings".
See "Assisted pump setup" on page 84.
2. Choose "Remote".
– "Return to factory settings".
3. Enter the connection code in the field "Preset * Applies only for pumps with advanced functional module, FM 300.
connection code". The field now says "Connection For further information, see Identification of functional module on
code set". page 120.
You can always modify the default connection code by "Alarm log"
pressing [Delete] and entering a new one.
Pump variant "Alarm log"
If Grundfos GO fails to connect and ask you to press
TPE3, TPE3 D ●
the connection button on the product, it means that the
TPE2, TPE2 D ●
product has no connection code or has a different 2.2 - 11 kW, 2-pole
connection code. In this case, you can only establish ●
3 - 7.5 kW, 4-pole
TPE Series 1000
connection via the connection button. 15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole
After setting a connection code, you must switch off
the product until the light in Grundfos Eye turns off This menu contains a list of logged alarms from the
before you can use the new connection code. product. The log shows the name of the alarm, when
the alarm occurred and when it was reset.
Factory setting
See section 13. Factory settings of E-pumps.
83
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
84
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Setup, analog input" "Multipump setup" ("Setup of multi-pump system")
85
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
86
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Grundfos GO and wired pump connection Advanced control panel and wireless pump
87
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Advanced control panel and wired pump Disabling a multipump via advanced control panel
User interfaces for TPE pumps
"Alternating operation, time" and if the pumps are This menu gives guidance and corrective actions in
fitted with FM 300. case of pump failures.
15.Press [>] to continue.
16.Press [OK].
The multipump function icons appear in the bottom
of the control panels.
The multipump system has now been set.
Disabling the multipump function via Grundfos GO
1. Select the "Assist" menu.
2. Select "Multipump setup".
3. Select "Disable".
4. Press [>] to continue.
5. Confirm the multipump setup by pressing [Send].
6. Press [Finish].
The multipump function has now been disabled.
88
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Priority of settings
1 "Stop"
2 "Stop"*
3 "Manual"
5 "Stop"
6 "User-defined speed"
7 "Stop"
8 "Max. speed"
9 "Min. speed"
10 "Start"
11 "Max. speed"
12 "Min. speed"
13 "Min. speed"
14 "Start"
15 "Start"
89
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Grundfos Eye
User interfaces for TPE pumps
AA
Warning.
One yellow indicator light is permanently on.
The pump has stopped.
Alarm.
The two opposite red indicator lights flash simultaneously.
The pump has stopped.
The green indicator light in the middle flashes quickly four
times. This is a feedback signal which the pump gives in order
to ensure identification of itself.
The green indicator light in the middle flashes continuously. Grundfos GO or another pump is trying to communicate
with the pump. Press on the pump control panel to
allow communication.
The green indicator light in the middle is permanently on. Remote control with Grundfos GO via radio.
The pump is communicating with Grundfos GO via radio
connection.
The green indicator light in the middle flashes quickly while
Grundfos Go is exchanging data with the pump. It takes a Remote control with Grundfos GO via infrared light.
few seconds. The pump is receiving data from Grundfos GO via
infrared communication.
90
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Indicator lights and signal relays
Off C NO NC C NO NC C NO NC C NO NC C NO NC
"Normal",
The pump runs in "Normal"
"Min." or
mode.
"Max."
Green, rotating C NO NC C NO NC C NO NC C NO NC C NO NC
"Normal",
Warning, but the pump runs. "Min." or
"Max."
Yellow, rotating C NO NC C NO NC C NO NC C NO NC C NO NC
"Normal,"
Alarm, but the pump runs. "Min." or
"Max."
Red, rotating C NO NC C NO NC C NO NC C NO NC C NO NC
91
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
92
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
The functions of the two indicator lights and the signal
"Pump running"
"Fault"/"Alarm",
"Warning" and
"Relubricate"
Description
"Operating"
Fault Operation
red green
"Ready"
Off Off The power supply has been switched off.
C NO NC C NO NC C NO NC C NO NC
C NO NC C NO NC C NO NC C NO NC
C NO NC C NO NC C NO NC C NO NC
The pump has stopped because of a "Fault"
or "Alarm". Or the pump runs with a
"Warning" or "Relubricate" indication.
Permanently on Off
If the pump was stopped, restarting will be
C NO NC C NO NC C NO NC C NO NC attempted. It may be necessary to restart
the pump by resetting the "Fault" indication.
The pump runs, but it has or has had a
"Fault" or "Alarm" allowing the pump to
continue operation. Or the pump runs with a
"Warning" or "Relubricate" indication.
If the cause is "Sensor signal outside signal
range", the pump continues to run
according to the maximum curve, and you
Permanently on Permanently on
cannot reset the fault indication until the
C NO NC C NO NC C NO NC C NO NC signal is inside the signal range.
If the cause is "Setpoint signal outside
signal range", the pump continues to run
according to the minimum curve, and you
cannot reset the fault indication until the
signal is inside the signal range.
93
13 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
● Function is enabled.
❍ Function is disabled.
- Function is not available.
TPE2, TPE2 D
Function
Settings Comments
description
94
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
14
14. Communication
Communication
Communication with TPE2, TPE2
D, TPE3, TPE3 D and TPE pumps
Communication with TPE2, TPE2 D, TPE3, TPE3 D
and TPE pumps is possible via a central building
management system, remote control, Grundfos GO or
control panel.
Central building management system
The operator can communicate with a TPE2, TPE2 D,
TPE3, TPE3 D and TPE pump at a distance.
Communication can take place via a central building
management system allowing the operator to monitor
and change control modes and setpoint settings.
Remote control
The operator can monitor and change control modes
and settings of the pump with Grundfos GO. See
Grundfos GO on page 54.
95
15 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
pumps
Affinity equations H
Q n
Normally, the pumps are used in applications n n
-------- ------
Q n
characterised by a variable flow. Consequently, you Hn
x x
cannot to select a pump that is constantly operating at
its optimum efficiency. H n n 2
Hx nn n
------- ------
In order to achieve optimum operating economy, the H
x n x
nx
duty pump must be close to the optimum efficiency,
eta, for most operating hours.
Between the minimum and maximum performance
Q
curves, the pumps have an infinite number of Eta
Qx Qn
performance curves each representing a specific
n
speed. Therefore, you may not be able to select a duty ------- 1
x
point close to the maximum curve.
H
H
[m] nx nn
[m]
Maximum curve
Q
P Qx Qn
Pn n n 3
------- ------
nn Px n x
Pn
Minimum curve
0 Q
3
0 QQ[m³/h]
[m h] Fig. 74 Affinity equations
96
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
16
TPE3 D
TPE2
TPE3
97
16 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
2000
TPE3 pumps are connected directly to Grundfos
Control MPC Series 2000 via GENIbus.
Control MPC Series 2000 incorporates a CU 352
control unit that can control up to six pumps.
All pumps must be of the same type and size.
Control MPC Series 2000 is used for controlling
circulator pumps in heating and air-conditioning
applications.
Control MPC Series 2000 ensures optimal adaptation
of the performance to the demand by closed-loop
control of these parameters:
• proportional differential pressure
• constant differential pressure.
By means of an external sensor Control MPC Series
2000 can also ensure optimum adaptation of the
performance to the demand by closed-loop control of
these parameters:
• differential pressure (remote)
• flow rate
• temperature.
Note: For further information about Control MPC and
Control MPC Series 2000, see the data booklet
"Control MPC". The data booklet is available online in
Grundfos Product Center. See page 224.
98
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
17
Grundfos CUE
TP pumps connected to Grundfos Smart user interface
99
18 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
0.37
Pump type Mounting designation - IEC 34-7
TP Series 200 IM 3601 (IM B 14) / IM 3611 (IM V 18) 0.55
1.1
Relative humidity: Maximum 95 %
Enclosure class: IP55 1.5
Insulation class: F (IEC 85) 2.2 MG
Ambient temperature: See page 18.
3.0
MG MGE*
If the pump is installed in humid locations, open the 4.0
lowest drain hole in the motor. This will reduce the MGE*
5.5
motor enclosure class to IP44.
7.5
High-efficiency motors
11.0
TP pumps are primarily fitted with motors that meet the
legislative requirements of the EuP IE3 or IE2 grade 15.0 MGE
depending on voltage and motor size. For further 18.5 MGE
information see pages 101 to 104.
22.0
TPE2, TPE2 D, TPE3, TPE3 D pumps are fitted with
Grundfos permanent-magnet MGE motors that have 30.0
motor efficiency class IE5 according to IEC 37.0
60034-30-2.
45.0
TPE pumps with 2-pole motors up to 11 kW and 4-pole
motors up to 7.5 kW are fitted with Grundfos 55.0
permanent-magnet MGE motors that have motor 75.0
efficiency class IE5 according to IEC 60034-30-2. Siemens
90.0 Siemens
TPE pumps with three-phase 2-pole motors from 15 to
22 kW are fitted with motors equivalent to IE3. 110.0
315.0
* IE5 motors
100
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
18
Electrical data, mains-operated motors
Motor data
Electrical data, 2-pole 3 x 220-240/380-420 V and 3 x 255-277/440-480 V
3 x 220-240/380-420 V 3 x 255-277/440-480 V
* Applies to 230/400 V
** Applies to 265/460 V
101
18 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
3 x 380-420/660-690 V 3 x 440-480 V
30.0 56.0 - 50.0 / 32.0 - 30.5 0.89 92.4 3545 6.1 IE3 34.5 54.0 - 50.0 0.87 93.0 3550 6.6 IE3
37.0 69.0 - 62.0 / 38.5 - 37.0 0.90 93.0 3540 5.8 IE3 42.5 67.0 - 61.0 0.87 93.6 3550 6.7 IE3
45.0 81.0 - 73.0 / 47.0 - 44.5 0.90 94.2 3556 7.6 IE3 51.0 79.0 - 74.0 0.89 93.6 3560 6.8 IE3
55.0 96.0 - 89.0 / 55.0 - 54.0 0.90 94.0 3570 7.3 IE3 62.0 96.0 - 89.0 0.90 93.6 3575 6.7 IE3
75.0 135-122 / 78.0 - 74.0 0.90 93.8 3570 7.4 IE3 84.0 130-122 0.89 94.5 3575 6.8 IE3
90.0 161-145 / 93.0 - 88.0 0.91 94.4 3570 7.8 IE3 101.0 156-143 0.90 94.5 3575 7.2 IE3
110.0 194-174 / 112-106 0.91 95.1 3579 7.8 IE3 123.0 186-171 0.91 95.0 3582 7.2 IE3
132.0 230-210 / 133-127 0.92 94.8 3579 8.0 IE3 148.0 225-205 0.91 95.4 3582 7.1 IE3
160.0 260-235 / 150-142 0.92 95.3 3582 9.1 IE3 180.0 270-250 0.92 95.4 3582 7.7 IE3
- - - - - - - 224.0 335-305 0.92 95.8 3582 7.1 IE3
- - - - - - - 280.0 420-385 0.92 95.4 3585 8.7 IE3
* Applies to 400/690 V
** Applies to 400 V
3 x 220-240/380-420 V 3 x 255-277/440-480 V
18.5 63.0 - 57.0 / 36.5 - 33.0 0.84 92.4 1765 6.2 IE3 21.3 62.5 - 57.0 / 36.0 - 33.0 0.83 93.6 1770 7.0 IE3
22 73.5 - 70 / 42.5 - 40.5 0.84 92.4 1765 6.0 IE3 25.3 74.5 - 70.0 / 43.0 - 40.5 0.83 93.6 1770 6.9 IE3
30 99.5 - 93.5 / 57.5 - 54.0 0.85 93.0 1765 6.1 IE3 34.5 99.0 - 92.5 / 57.0 - 53.5 0.85 93.0 1770 7.2 IE3
37 120-109 / 69-63 0.86 94.0 1776 5.4 IE3 42.5 119-111 / 69-64 0.86 93.6 1778 6.7 IE3
45 147-132 / 85-76 0.86 94.3 1775 5.3 IE3 52 146-137 / 84-79 0.86 94.1 1778 6.6 IE3
55 177-159 / 102-92 0.87 94.7 1780 5.4 IE3 63.0 175-163 / 101-94 0.87 94.1 1782 6.7 IE3
75 240-215 / 139-125 0.87 94.8 1783 5.4 IE3 86.0 235-220 / 136-127 0.87 95.4 1785 6.8 IE3
90 290-260 / 166-150 0.87 94.9 1783 5.6 IE3 104 285-265 / 165-153 0.87 95.0 1785 7.0 IE3
110 345-315 / 200-181 0.87 95.4 1786 5.5 IE3 127 345-320 / 199-185 0.87 95.8 1788 6.9 IE3
132 415-370 / 240-215 0.88 95.8 1788 5.8 IE3 152 405-375 / 235-220 0.88 96.2 1788 7.2 IE3
160 470-425 / 270-245 0.88 96.1 1789 5.8 IE3 184 495-460 / 285-265 0.88 96.2 1788 7.2 IE3
200 580-520 / 335-300 0.88 95.7 1788 6.0 IE3 230 620-580 / 360-335 0.88 95.4 1788 7.5 IE3
* Applies to 230/400 V
** Applies to 265/460 V
0.12 0.37 - - - - -
0.25 1.21 / 0.7 0.8 - 0.69 71-72 1680-1720 4 - 4.7 -
0.37 1.72 / 0.99 0.82 - 0.72 73-74 1680-1720 4 - 4.7 -
0.55 2.4 / 1.4 0.83 - 0.75 77-80 1660-1710 3.9 - 4.5 -
0.75 3.1 / 1.8 0.84 - 0.76 77-81 1660-1710 3.9 - 4.7 IE2
102
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
18
Electrical data, 4-pole 3 x 220-277/380-480 V Electrical data, 4-pole 3 x 380-480/660-690 V
Motor data
Motor I1/1 IStart IE Motor I1/1 IStart IE
Cos φ 1/1 η [%] n [min-1] ------------ Cos φ 1/1 η [%] n [min-1] ------------
[kW] [A] I 1/1 class [kW] [A] I 1/1 class
18.5 36.5 - 33.0 / 21.0 - 20.0 0.84 92.4 1765 6.2 IE3 21.3 36.0 - 33.0 0.83 93.6 1770 7.0 IE3
22.0 42.5 - 40.5 / 24.5 - 24.0 0.84 92.4 1765 6.0 IE3 25.3 43.0 - 40.5 0.83 93.6 1770 6.9 IE3
30.0 57.5 - 54.0 / 33.5 - 32.0 0.85 93.0 1765 6.1 IE3 34.5 57.0 - 53.5 0.85 93.0 1770 7.2 IE3
37.0 69.0 - 63.0 / 40.0 - 38.0 0.86 94.0 1776 5.4 IE3 42.5 69.0 - 64.0 0.86 93.6 1778 6.7 IE3
45.0 85.0 - 76.0 / 49.0 - 46.0 0.86 94.3 1775 5.3 IE3 52.0 84.0 - 79.0 0.86 94.1 1778 6.6 IE3
55.0 102 - 92.0 / 59.0 - 56.0 0.87 94.7 1780 5.4 IE3 63.0 101 - 94.0 0.87 94.1 1782 6.7 IE3
75.0 139-125 / 80.0 - 76.0 0.87 94.8 1783 5.4 IE3 86.0 136-127 0.87 95.4 1785 6.8 IE3
90.0 166-150 / 96.0 - 91.0 0.87 94.9 1783 5.6 IE3 103.5 165-153 0.87 95.0 1785 7.0 IE3
110.0 200-181 / 115-109 0.87 95.4 1786 5.5 IE3 126.5 199-185 0.87 95.8 1788 6.9 IE3
132.0 240-215 / 138-131 0.88 95.8 1788 5.8 IE3 151.8 235-220 0.88 96.2 1788 7.2 IE3
160.0 270-245 / 156-148 0.88 96.1 1789 5.8 IE3 184.0 285-265 0.88 96.2 1788 7.2 IE3
200.0 335-300 / 192-182 0.88 95.7 1788 6.0 IE3 230.0 360-335 0.88 95.4 1788 7.5 IE3
250.0 415-370 / 240-225 0.86 95.9 1789 7.7 IE3 - - - - - - -
300.0 560-500 / 320-305 0.85 95.9 1788 7.9 IE3 - - - - - - -
* Applies to 400/690 V
** Applies to 400 V
103
18 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Electrical data, 1 x 200-240 V, TPE2, TPE3 pumps Electrical data, 2-pole 3 x 380-500 V, 4000 min-1
Motor Motor [kW] I1/1 [A]
Pump type I1/1 [A]
[kW]
2.2 4.15 - 3.40
TPE2, TPE2 D, TPE3, TPE3 D 32-80 0.25 1.56 3 5.80 - 4.80
TPE2, TPE2 D, TPE3, TPE3 D 32-120 0.25 1.56 4 7.60 - 6.20
TPE2, TPE2 D, TPE3, TPE3 D 32-150 0.37 2.29 5.5 10.3 - 8.20
TPE2, TPE2 D, TPE3, TPE3 D 32-180 0.55 3.15 7.5 14.1 - 11.2
TPE2, TPE2 D, TPE3, TPE3 D 32-200 0.75 4.17 11 20.3 - 16.0
TPE2, TPE2 D, TPE3, TPE3 D 40-80 0.25 1.56
TPE2, TPE2 D, TPE3, TPE3 D 40-120 0.37 2.17 Electrical data, 4-pole 3 x 380-500 V, 2000 min-1
TPE2, TPE2 D, TPE3, TPE3 D 40-150 0.55 3.04
TPE2, TPE2 D, TPE3, TPE3 D 40-180 0.75 4.17 Motor [kW] I1/1 [A]
TPE2, TPE2 D, TPE3, TPE3 D 40-200 1.1 5.97 1.5 2.90 - 2.50
TPE2, TPE2 D, TPE3, TPE3 D 40-240 1.5 8.00 2.2 4.30 - 3.60
TPE2, TPE2 D, TPE3, TPE3 D 50-60 0.37 2.17 3 5.80 - 4.60
TPE2, TPE2 D, TPE3, TPE3 D 50-80 0.37 2.17 4 7.70 - 6.00
TPE2, TPE2 D, TPE3, TPE3 D 50-120 0.55 3.04 5.5 10.5 - 8.40
TPE2, TPE2 D, TPE3, TPE3 D 50-150 0.75 4.1 7.5 14.1 - 11.1
TPE2, TPE2 D, TPE3, TPE3 D 50-180 1.1 5.97
TPE2, TPE2 D, TPE3, TPE3 D 50-200 1.5 8.00 Electrical data, 2-pole 3 x 380-480 V, 2900 min-1
TPE2, TPE2 D, TPE3, TPE3 D 65-60 0.37 2.17
TPE2, TPE2 D, TPE3, TPE3 D 65-80 0.55 3.04 Motor [kW] I1/1 [A]
TPE2, TPE2 D, TPE3, TPE3 D 65-120 0.75 4.10 15.0 30.0 - 26.0
TPE2, TPE2 D, TPE3, TPE3 D 65-150 1.1 5.97 18.5 37.0 - 31.0
TPE2, TPE2 D, TPE3, TPE3 D 65-180 1.5 8.00 22.0 43.5 - 35.0
TPE2, TPE2 D, TPE3, TPE3 D 80-40 0.25 1.46
TPE2, TPE2 D, TPE3, TPE3 D 80-120 1.1 5.88 Electrical data, 4-pole 3 x 380-480 V, 1450 min-1
TPE2, TPE2 D, TPE3, TPE3 D 80-150 1.5 7.97
TPE2, TPE2 D, TPE3, TPE3 D 100-40 0.25 1.46 Motor [kW] I1/1 [A]
TPE2, TPE2 D, TPE3, TPE3 D 100-120 1.1 5.88 11.0 22.0 - 17.8
TPE2, TPE2 D, TPE3, TPE3 D 100-150 1.5 7.97 15.0 30.0 - 25.4
18.5 37.0 - 30.0
Electrical data, 3 x 380-500 V, TPE2, TPE2 D, TPE3,
TPE3 D pumps
Motor
Pump type I1/1 [A]
[kW]
TPE2, TPE2 D, TPE3, TPE3 D 32-80 0.25 0.88
TPE2, TPE2 D, TPE3, TPE3 D 32-120 0.25 0.88
TPE2, TPE2 D, TPE3, TPE3 D 32-150 0.37 1.09
TPE2, TPE2 D, TPE3, TPE3 D 32-180 0.55 1.34
TPE2, TPE2 D, TPE3, TPE3 D 32-200 0.75 1.68
TPE2, TPE2 D, TPE3, TPE3 D 40-80 0.25 0.88
TPE2, TPE2 D, TPE3, TPE3 D 40-120 0.37 1.09
TPE2, TPE2 D, TPE3, TPE3 D 40-150 0.55 1.34
TPE2, TPE2 D, TPE3, TPE3 D 40-180 0.75 1.68
TPE2, TPE2 D, TPE3, TPE3 D 40-200 1.1 2.26
TPE2, TPE2 D, TPE3, TPE3 D 40-240 1.5 2.96
TPE2, TPE2 D, TPE3, TPE3 D 50-60 0.37 1.04
TPE2, TPE2 D, TPE3, TPE3 D 50-80 0.37 1.04
TPE2, TPE2 D, TPE3, TPE3 D 50-120 0.55 1.34
TPE2, TPE2 D, TPE3, TPE3 D 50-150 0.75 1.68
TPE2, TPE2 D, TPE3, TPE3 D 50-180 1.1 2.26
TPE2, TPE2 D, TPE3, TPE3 D 50-200 1.5 2.96
TPE2, TPE2 D, TPE3, TPE3 D 50-240 2.2 4.22
TPE2, TPE2 D, TPE3, TPE3 D 65-60 0.37 1.04
TPE2, TPE2 D, TPE3, TPE3 D 65-80 0.55 1.34
TPE2, TPE2 D, TPE3, TPE3 D 65-120 0.75 1.68
TPE2, TPE2 D, TPE3, TPE3 D 65-150 1.1 2.15
TPE2, TPE2 D, TPE3, TPE3 D 65-180 1.5 2.96
TPE2, TPE2 D, TPE3, TPE3 D 65-200 2.2 4.22
TPE2, TPE2 D, TPE3, TPE3 D 80-40 0.25 0.82
TPE2, TPE2 D, TPE3, TPE3 D 80-120 1.1 2.15
TPE2, TPE2 D, TPE3, TPE3 D 80-150 1.5 2.82
TPE2, TPE2 D, TPE3, TPE3 D 80-180 2.2 4.03
TPE2, TPE2 D, TPE3, TPE3 D 100-40 0.25 0.82
TPE2, TPE2 D, TPE3, TPE3 D 100-120 1.1 2.15
TPE2, TPE2 D, TPE3, TPE3 D 100-150 1.5 2.82
TPE2, TPE2 D, TPE3, TPE3 D 100-180 2.2 4.03
104
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
19
19. Installation
Installation
Mechanical installation
You can install TP pumps with motors smaller than 11
kW in horizontal or vertical pipes.
105
19 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
60 Hz
TP, TPE 65-480/2 ● - 11 - ●
TP, TPE 65-540/2 ● - 15 - ●
TP, TPE 65-630/2 ● - 18.5 - ●
TP, TPE 65-740/2 ● - 22 - ●
TP, TPE 80-330/2 ● - 11 - ●
TP, TPE 80-400/2 ● - 15 - ●
TP, TPE 80-480/2 ● - 18.5 - ●
TP, TPE 80-530/2 ● - 22 - ●
TP, TPE 100-300/2 ● - 11 - ●
TP, TPE 100-370/2 ● - 15 - ●
TP, TPE 100-350/2 ● - 18.5 - ●
TP, TPE 100-380/2 ● - 22 - ●
TP, TPE 80-340/4 ● - 11 - ●
TP, TPE 80-410/4 ● - 15 - ●
TP, TPE 80-460/4 ● - 18.5 - ●
TP 80-510/4 ● - 22 - ●
TP, TPE 100-240/4 ● ● 11 ● ●
TP, TPE 100-260/4 ● - 11 - ●
TP, TPE 100-290/4 ● ● 15 ● ●
TP, TPE 100-340/4 ● ● 18.5 ● ●
TP 100-350/4 ● - 22 - ●
TP 100-390/4 ● ● 22 ● ●
TP 100-470/4 - ● 30 ● -
TP 100-560/4 - ● 37 ● -
TP, TPE 125-200/4 ● - 11 - ●
TP, TPE 125-230/4 ● - 15 - ●
TP, TPE 125-220/4 - ● 15 - ●
TP, TPE 125-280/4 ● ● 18.5 - ●
TP 125-340/4 ● ● 22 - ●
TP 125-365/4 - ● 30 ● -
TP 125-420/4 - ● 30 ● -
TP 125-480/4 - ● 37 ● -
TP 125-550/4 - ● 45 ● -
TP 125-580/4 - ● 55 ● -
TP, TPE 150-180/4 ● ● 15 - ●
TP, TPE 150-210/4 ● ● 18.5 - ●
TP 150-240/4 ● ● 22 - ●
TP 150-300/4 - ● 30 ● -
TP 150-340/4 - ● 37 ● -
TP 150-360/4 - ● 30 ● -
TP 150-400/4 - ● 37 ● -
TP 150-440/4 - ● 45 ● -
TP 150-480/4 - ● 55 ● -
TP 150-610/4 - ● 75 ● -
TP 150-810/4 - ● 110 ● -
TP 150-960/4 - ● 132 ● -
TP 200-250/4 - ● 30 ● -
TP 200-400/4 - ● 75 ● -
TP 200-430/4 - ● 55 ● -
TP 300-230/4 - ● 45 ● -
TP 300-270/4 - ● 55 ● -
TP 300-360/4 - ● 75 ● -
TP 300-370/4 - ● 90 ● -
TP 300-440/4 - ● 110 ● -
TP 300-550/4 - ● 132 ● -
TP 300-630/4 - ● 160 ● -
TP 300-640/4 - ● 200 ● -
TP 300-750/4 - ● 250 ● -
TP 350-400/4 - ● 132 ● -
TP 350-450/4 - ● 160 ● -
TP 350-540/4 - ● 200 ● -
TP 350-680/4 - ● 250 ● -
106
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
19
In installations where the pump is suspended directly For further information about identification of TP Series
Installation
in the pipes, the pump can support the pipe length L on 300 models, see pages 24 to 26.
both sides of the pump. L is less than 3 x DN. See fig. If the liquid temperature falls below the ambient
79. In installations where the pump is suspended temperature or if the pump is installed outside,
directly in the pipes, the pump must be lifted and held condensation may form in the motor during inactivity.
in correct position by means of ropes or similar until In this case, the drain hole in the motor flange must be
both pump flanges are completely fastened to the pipe open and point downwards. See fig. 82.
flanges.
Vertical pipe
L Horizontal pipe
107
19 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
When installing the pumps outdoors, provide the motor Install the pump on a plane and rigid concrete
with a suitable cover to protect the pump and motor foundation. This is the optimum solution for vibration
against the direct effects of the elements. dampening. As a rule of thumb, the weight of a
When mounting the condensation cover on top of the concrete foundation must be 1.5 times the pump
motor, make sure to leave enough space for the air to weight.
cool the motor. Recommended concrete foundations for TP, TPD
Series 300 pumps
For TP Series 300 pumps with weights of 150 kg or
more, we recommend that you mount the pump on a
concrete foundation with the dimensions stated in the
table below. The same recommendation applies to
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
108
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
19
Expansion joints
Installation
Concrete foundation dimensions
Pump mass
[kg] X (Height) Y (Length) Z (Width) Expansion joints do the following:
[mm] [mm] [mm] • absorb expansions or contractions in the pipes
800 450 1400 800 caused by changing liquid temperature.
1000 450 1400 1000
• reduce mechanical strains in connection with
1200 450 1400 1200
pressure surges in the pipes.
1400 500 1600 1200
1600 500 1600 1350 • isolate mechanical structure-borne noise in the
1800 500 1600 1500 pipes. Only rubber bellows expansion joints.
2000 550 1600 1600 Note: Do not install expansion joints to compensate for
2200 DN 300 / 550 1700 1700 inaccuracies in the pipes such as centre displacement
2400 DN 350 / 550 1800 1800
DN 400
of flanges.
2600 600 1800 1800
3000 600 2000 2000 Fit expansion joints at a distance of minimum 1 to 1.5
3400 680 2000 2000 times the nominal flange diameter away from the pump
3800 760 2000 2000 on the inlet as well as on the outlet side. This prevents
4200 840 2000 2000 the development of turbulence in the expansion joints,
4600 920 2000 2000 resulting in better suction conditions and a minimum
5000 1000 2000 2000 pressure loss on the outlet side. At high water
5400 1080 2000 2000 velocities, greater than 5 m/s, we recommend that you
Vibration dampers install larger expansion joints corresponding to the
To prevent the transmission of vibrations to buildings, pipes. See fig. 86.
we recommend that you isolate the pump foundation Expansion joints
from building parts by means of vibration dampers.
The selection of the right vibration damper requires the
following data:
• Forces transmitted through the damper.
• Motor speed considering speed control, if any.
• Required dampening in %. The suggested value is
109
19 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
You can use expansion joints with limit rods to reduce Electrical installation
Installation
110
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20
MGE motors
Motors for TPE2, TPE2 D, TPE3, Inputs and outputs
TPE3 D pumps and 2.2 - 11 kW Earth reference, GND
2-pole motors and 1.5 - 7.5 kW All voltages refer to GND.
All currents return to GND.
4-pole motors fitted on TPE Series
Absolute maximum voltage and current limits
1000 pumps
Exceeding the following electrical limits may result in
Single-phase supply voltage severely reduced operating reliability and motor life:
Relay 1:
1 x 200-240 V - 10 %/+ 10 %, 50/60 Hz, PE.
Maximum contact load: 250 VAC, 2 A or 30 VDC, 2 A.
Recommended fuse size Relay 2:
Motor size Min. Max. Maximum contact load: 30 VDC, 2 A.
[kW] [A] [A] GENI terminals: -5.5 to 9.0 VDC or less than 25
0.25 - 0.75 6 10 mADC.
1.1 - 1.5 10 16
Other input or output terminals: -0.5 to 26 VDC or less
You can use standard as well as quick-blow or than 15 mADC.
slow-blow fuses.
Digital inputs, DI
Leakage current Internal pull-up current greater than 10 mA at Vi equal
Earth leakage current less than 3.5 mA, AC. to 0 VDC.
Earth leakage current less than 10 mA, DC supply. Internal pull-up to 5 VDC (currentless for Vi greater
The leakage currents are measured in accordance with than 5 VDC).
EN 61800-5-1:2007. Certain low logic level: Vi less than 1.5 VDC.
Certain high logic level: Vi greater than 3.0 VDC.
Three-phase supply voltage Hysteresis: No.
3 x 380-500 V - 10 %/+ 10 %, 50/60 Hz, PE. Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Recommended fuse size Maximum cable length: 500 m.
111
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
112
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20
EMC (electromagnetic compatibility) Cable entries
MGE motors
Standard used: EN 61800-3. TPE Series 1000
The table below shows the emission category of the
Number and size of cable entries
motor.
Motor 1400-2000
C1 fulfils the requirements for residential areas. [kW] 1450-2200
2900-4000
min-1
Note: When connected to a public network, 11 kW min-1
motors do not comply with the partial weighted 1.5 4 x M20 4 x M20
harmonic distortion (PWHD) requirements of EN 2.2 1 x M25 + 4 x M20 4 x M20
61000-3-12. If required by the distribution network 3.0 - 4.0 1 x M25 + 4 x M20 1 x M25 + 4 x M20
5.5 1 x M32 + 5 x M20 1 x M25 + 4 x M20
operator, compliance can be obtained in the following
7.5 - 11 1 x M32 + 5 x M20 1 x M32 + 5 x M20
way:
The impedance of the mains cables between the motor TPE2, TPE2 D, TPE3, TPE3 D
and the point of common coupling (PCC) must be Number and size of cable entries: 4 x M20.
equivalent to the impedance of a 50 m cable with a
cross-section of 0.5 mm. Sound pressure level
C3 fulfils the requirements for industrial areas. TPE Series 1000
Note: When the motors are installed in residential
areas, supplementary measures may be required as Maximum Sound pressure level
Motor speed stated Speed ISO 3743
the motors may cause radio interference. [dB(A)]
[kW] on nameplate [min-1]
[min-1] 3-phase motors
Emission category
Motor
2900-4000 min-1 1500 42
[kW] 1450-2000 min-1 2000
4000-5900 min-1 2000 47
1.5
0.25 C1 C1 3000 57
4000
0.37 C1 C1 4000 64
0.55 C1 C1 1500 48
2000
0.75 C1 C1 2000 55
2.2
1.1 C1 C1 3000 57
4000
1.5 C1 C1 4000 64
2.2 C1 C1 1500 48
2000
3 C1 C1 2000 55
3
4 C1 C1 3000 60
4000
5.5 C3/C1* C1 4000 69
7.5 C3/C1* C3/C1* 1500 48
2000
11 - C3/C1* 2000 55
4
3000 61
* 4000
C1, if equipped with an external Grundfos EMC filter. 4000 69
1500 58
Immunity: The motor fulfils the requirements for 2000
2000 61
industrial areas. 5.5
3000 61
4000
Contact Grundfos for further information. 4000 69
1500 58
2000
Enclosure class 7.5
2000 61
3000 66
Standard: IP55 (IEC 34-5). 4000
4000 73
Optional: IP66 (IEC 34-5). 3000 66
11 4000
4000 73
Insulation class
F (IEC 85).
Ambient temperature
During operation: -20 to 50 °C.
During storage and transportation: -30 to 60 °C.
113
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
114
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20
Maximum number of starts and stops Connection terminals
MGE motors
The number of starts and stops via the power supply The descriptions and terminal overviews in this section
must not exceed four times per hour. apply to both single-phase and three-phase motors.
When switched on via the power supply, the pump Connection terminals, advanced functional
starts after approximately 5 seconds. module, FM 300
If you want a higher number of starts and stops, use The advanced module has these connections:
the input for external start-stop when starting or • three analog inputs
stopping the pump. • one analog output
When you start the pump via an external on/off switch, • two dedicated digital inputs
the pump starts immediately.
• two configurable digital inputs or open-collector
Wiring diagrams outputs
• Input and output for Grundfos Digital Sensor
Single-phase supply:
Not applicable for TPE Series 1000 and TPE2,
RCD, TPE2 D pumps.
type B The factory-fitted differential-pressure sensor for
TPE3, TPE3 D pumps is connected to this input.
L2 L2
L3
• Inputs and outputs
L3
All inputs and outputs are internally separated from
PE
the mains-conducting parts by reinforced insulation
and galvanically separated from other circuits.
Fig. 91 Example of a mains-connected motor with mains All control terminals are supplied by protective
switch, backup fuse and additional protection extra-low voltage, PELV, thus ensuring protection
against electric shock.
• Signal relay outputs
– Signal relay 1:
LIVE:
You can connect supply voltages up to 250 VAC.
PELV:
The output is galvanically separated from other
circuits. Therefore, you can connect the supply
voltage or protective extra-low voltage to the
output as desired.
– Signal relay 2:
PELV:
The output is galvanically separated from other
circuits. Therefore, you can connect the supply
voltage or protective extra-low voltage to the
output as desired.
• Mains supply, terminals N, PE, L or L1, L2, L3, PE.
115
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
MGE motors
18 GND Earth
Digital input/output,
configurable.
11 DI4/OC2
Open collector: Maximum
24 V resistive or inductive.
19 Pt100/1000 input 2 Pt100/1000 sensor input
NC 17 Pt100/1000 input 1 Pt100/1000 sensor input
C1 Analog output:
NO 12 AO 0-20 mA / 4-20 mA
0-10 V
NC
9 GND Earth
C2
Analog input:
NO
14 AI3 0-20 mA / 4-20 mA
OC DI
18 GND 0-10 V
+24 V*
11 DI4/OC2 1 DI2 Digital input, configurable
19 Pt100/1000
LiqTec sensor input
17 Pt100/1000 21 LiqTec sensor input 1
White conductor
12 AO
Earth
+24 V* +24 V*/5 V* +5 V* 9 GND 20 GND
+24 V* + +
Brown and black conductors
14 AI3
LiqTec sensor input
1 DI2 22 LiqTec sensor input 2
Blue conductor
21 LiqTec
20 GND Digital input/output,
configurable.
22 LiqTec 10 DI3/OC1
OC DI Open collector: Maximum
+24 V* GND
10 DI3/OC1 24 V resistive or inductive.
4 AI1 Analog input:
+24 V* +24 V* +24 V*/5 V* 2 DI1 4 AI1 0-20 mA / 4-20 mA
+ +
5 +5 V
0.5 - 3.5 V / 0-5 V / 0-10 V
6 GND 2 DI1 Digital input, configurable
A GENIbus A Supply to potentiometer and
5 +5 V
Y GENIbus Y
sensor
B GENIbus B
6 GND Earth
A GENIbus, A GENIbus, A (+)
3 GND
15
Y GENIbus, Y GENIbus, GND
+24 V
8
B GENIbus, B GENIbus, B (-)
+24 V
26 +5 V 3 GND Earth
TM05 3509 3512
23 GND
15 +24 V Supply
25 GDS TX
+24 V* +24 V* +24 V*/5 V*
+ + 8 +24 V Supply
24 GDS RX
Supply to potentiometer and
+5 V* 7 26 +5 V
AI2 sensor
23 GND Earth
* If an external supply source is used, there must be a connection to Grundfos Digital Sensor
GND. 25 GDS TX
output
Grundfos Digital Sensor
Fig. 92 Connection terminals, FM 300 (option) 24 GDS RX
input
Analog input:
7 AI2 0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V / 0-10 V
116
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20
MGE motors, 11 to 18.5 kW, 4-pole, Setpoint signals
MGE motors
• Potentiometer
and 15 to 22 kW, 2-pole 0-10 VDC, 10 kΩ via internal voltage supply.
Grundfos MGE 100, MGE 112, MGE 132, MGE 160 Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
and MGE 180 motors offer these features: Maximum cable length: 100 m.
• Three-phase mains connection. • Voltage signal
• Three-phase, asynchronous squirrel-cage induction 0-10 VDC, Ri greater than 50 kΩ.
motors designed to current IEC, DIN and VDE Tolerance: + 0 %/- 3 % at maximum voltage signal.
guidelines and standards. The motors incorporate a Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
frequency converter and PI controller. Maximum cable length: 500 m.
• Used for continuously variable speed control of • Current signal
Grundfos E-pumps available in power sizes 11 to DC 0-20 mA / 4-20 mA, Ri equal to 175 Ω.
18.5 kW, 4-pole, and 15 to 22 kW, 2-pole. Tolerance: + 0 %/- 3 % at maximum current signal.
Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Supply voltage Maximum cable length: 500 m.
3 x 380-480 V - 10 %/+ 10 %, 50/60 Hz, PE. Sensor signals
Backup fuse • Voltage signal
0-10 VDC, Ri greater than 50 kΩ via internal voltage
Motor size Maximum fuse supply.
[kW] [A]
Tolerance: + 0 %/- 3 % at maximum voltage signal.
11 26
Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
15 36
Maximum cable length: 500 m.
18.5 43
22 51 • Current signal
DC 0-20 mA / 4-20 mA, Ri = 175 Ω.
You can use standard as well as quick-blow or Tolerance: + 0 %/- 3 % at maximum current signal.
slow-blow fuses. Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Leakage current Maximum cable length: 500 m.
• Power supply to sensor
Motor size Leakage current
[kW] [mA]
+24 VDC, maximum 40 mA.
11-22 > 10 Signal output
The leakage currents are measured in accordance with • Potential-free changeover contact.
EN 61800-5-1. Maximum contact load: 250 VAC, 2 A.
Minimum contact load: 5 VDC, 10 mA.
Input/output Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Maximum cable length: 500 m.
Start/stop
Bus input
• External potential-free switch.
Voltage: 5 VDC. Grundfos GENIbus protocol, RS-485.
Current: less than 5 mA. Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG. Maximum cable length: 500 m.
Digital input
• External potential-free switch.
Voltage: 5 VDC.
Current: less than 5 mA.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
117
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
118
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20
Maximum number of starts and stops • Group 3: Mains supply (terminals L1, L2, L3).
MGE motors
A galvanically safe separation must fulfil the
The number of starts and stops via the power supply
requirements for reinforced insulation including
must not exceed four times per hour.
creepage distances and clearances specified in EN
When switched on via the power supply, the pump 61800-5-1.
starts after approximately 5 seconds.
If a higher number of starts and stops is desired, use
Group 2
Group 3
the input for external start-stop when starting or
stopping the pump.
When started via an external on/off switch, the pump
starts immediately.
Group 1
A: RS-485A
connected to the connection groups are separated
from each other by reinforced insulation in their entire 6: GND (frame)
lengths. 5: +10 V
119
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
VARIANT
ype :
Typ
Type P.C. : INPUT
Hp VARIANT
OUTPUT
PB :
:
Xxxxxxxxxxx
P.N. : Serial no : U in P
P2 : Hp
PB :
rpm FMFM :
E.P. Motor
DE : Env.Type
Env.Ty ype
p : TEFC ~ V n max: rpm:
NDE : SF : CL: f in : Hz Eff : HMI : Made in Hungary
Wgt
Wggt : g Tamb :
kg F PF: I SF Ampp: A I 1/1 : A HMI
HMI:
CIM : : DK - 8850 Bjerringbro, Denmark
Variant Description
FM 200 Standard functional module
FM 300 Advanced functional module
120
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
21
121
21 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
environment?
The first environment, residential areas, includes
establishments directly connected to a low-voltage
power supply network which supplies domestic
buildings.
The second environment, industrial areas, includes
establishments which are not connected to a
low-voltage network that supplies domestic buildings.
The level of electromagnetic disturbance can be much
higher than in the first environment.
EMC and C-tick
122
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
22
D2 90 100 110 130 150 170 100 110 125 145 160 180 210 240 295 350
D3 120 130 140 160 190 210 140 150 165 185 200 220 250 285 340 395
D2
D3 S 4 x 14 4 x 14 4 x 14 4 x 14 4 x 19 4 x 19 4 x 19 4 x 19 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 8 x 23 12 x 23
PN 16 and PN 25 flanges
32 40 50 65 80 100 125 150 200 100 125 150 200 250 300
D1 32 40 50 65 80 100 125 150 200 100 125 150 200 250 300
TM02 7720 3803
D2 100 110 125 145 160 180 210 240 295 190 220 250 310 370 430
D2 D3 140 150 165 185 200 220 250 285 340 235 270 300 360 425 485
D3 S 4 x 19 4 x 19 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 12 x 23 8 x 23 8 x 28 8 x 28 12 x 28 12 x 31 16 x 31
123
23 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
7373( Pump type and frequency
+]
QH curve for the individual single-head pump.
The bold curve indicates the recommended
performance range.
4>PñK@
3
>N:@
The power curve indicates pump input power [P2].
4>PñK@
136+
>P@
4>PñK@
(WD
>@
The eta curve shows the pump efficiency.
4>PñK@
TM02 5040 2115
4>OV@
Y>PV@
124
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
23
Curve conditions
Curve charts
The guidelines below apply to the curves shown on the
following pages:
• Tolerances to ISO 9906:2012 Grade 3B.
• The curves apply to the performance of
single-head, three-phase pumps. For other pump
versions, please see the exact curves in Grundfos
Product Center. See page 224. For other pump
versions, the performance may differ for the
following reasons:
– The valve in twin-head pumps may cause losses.
– Note: Grundfos does not recommend continuous
parallel operation of twin-head pumps, except
TPE2 D, TPE3 D due to the increased flow in the
pump. An excessive flow results in noisy
operation, increased wear of the impeller due to
cavitation, etc.
• QH curves of the individual single-head pumps are
shown with expected speed of a three-phase
mains-operated motor. For further information, see
the tables of technical data on the following pages.
• Curves of TPE Series 1000 pumps are shown as
maximum curves (100 % curves) only. Please refer
to Grundfos Product Center for the exact curves.
See page 224.
• Measurements have been made with airless water
at a temperature of 20 °C.
• The curves apply to a kinematic viscosity of equal
to 1 mm2/s (1 cSt).
• Due to the risk of overheating, the pump must not
run constantly below the minimum flow rate
indicated by the bold curves.
• If the pumped liquid density and/or viscosity are
higher than those of water, it may be necessary to
use a motor with a higher performance.
125
24
DN 32
PN 6, 10, 16
Performance curves and technical data
+ +
>P@ >P@
73(
73('
73( 73('
4>PñK@ 4>PñK@
3
4>PñK@
(WD
>@
4>PñK@
TM05 8171 2115
4>OV@
Y>PV@
Note: The dotted Q, H curves apply to TPE2 D, TPE3 D in parallel operation.
126
24
DN 32
PN 6, 10, 16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
127
24
DN 40
PN 6, 10, 16
Performance curves and technical data
+ +
>P@ >P@
73( 73('
73( 73('
4>PñK@ 4>PñK@
3
4>PñK@
(WD
>@
4>PñK@
TM05 8172 2115
4>OV@
Y>PV@
128
24
DN 40
PN 6, 10, 16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
129
24
DN 50
PN 6, 10, 16
Performance curves and technical data
+ +
>P@ >P@
73( 73('
73(
73('
4>PñK@ 4>PñK@
3
Y>PV@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM05 8173 2115
4>OV@
Y>PV@
130
24
DN 50
PN 6, 10, 16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
131
24
DN 65
PN 6, 10, 16
Performance curves and technical data
+ +
>P@ >P@
73(
73('
73(
73('
4>PñK@ 4>PñK@
3
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM05 8174 2115
4>OV@
Y>PV@
132
24
DN 65
PN 6, 10, 16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
133
24
DN 80
PN 6, 10, 16
Performance curves and technical data
+ +
>P@ >P@
73(
73('
73( 73('
4>PñK@ 4>PñK@
3
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM05 8175 2115
4>OV@
Y>PV@
Note: The dotted Q, H curves apply to TPE2 D, TPE3 D in parallel operation.
134
24
DN 80
PN 6, 10, 16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
135
24
DN 100
PN 6, 10, 16
Performance curves and technical data
+ +
>P@ >P@
73( 73('
73( 73('
4>PñK@ 4>PñK@
3
Y>PV@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM05 8176 2115
4>OV@
136
24
DN 100
PN 6, 10, 16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
137
24
DN 32
2-pole, PN 6, 10, 16, 25
Performance curves and technical data
73
7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM02 5034 2115
4>OV@ 4>OV@
Y>PV@ Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
138
24
DN 32
2-pole, PN 6, 10, 16, 25
TP 32 -80/2 -160/2 -220/2 -260/2 -330/2 -300/2 -360/2 -450/2 -550/2 -680/2 -820/2
TPD - - - - - ● ● ● ● ● ●
TPE - - - - - ● ● ● ● ● ●
TPED - - - - - - - - - - -
Series 200 200 200 200 200 300 300 300 300 300 300
1~ TP - - - - - - - - - - -
3~ TP 71 71 80 90 90 90 100 112 132 132 160
IEC size
1~ TPE - - - - - - - - - - -
3~ TPE - - - - - 90 100 112 132 132 160
1~/3~ TP [kW] -/0.37 -/0.55 -/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11
P2
1~/3~ TPE [kW] - - - - - -/2.2 -/3 -/4 -/5.5 -/7.5 -/11
PN PN 6/10 PN 6/10 PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 32 32 32 32 32 32 32 32 32 32 32
1~/3~ TP [mm] -/142 -/142 -/142 -/142 -/178 -/178 -/198 -/220 -/220 -/260 -/314
AC
1~/3~ TPE [mm] - - - - - -/122 -/191 -/191 -/191 -/255 -/255
1~/3~ TP [mm] -/109 -/109 -/109 -/109 -/110 -/167 -/120 -/134 -/134 -/159 -/204
AD
1~/3~ TPE [mm] - - - - - -/158 -/201 -/201 -/201 -/237 -/237
AE 1~/3~ TPE [mm] - - - - - 132 146 146 146 237 237
AF 1~/3~ TPE [mm] - - - - - 132 146 146 146 237 237
P [mm] - - - - - 200 250 250 300 300 350
B1 ★ [mm] 75/- 75/- 102/- 102/- 102/- 144/321 144/321 144/321 144/321 144/321 144/321
B2 ★ [mm] 75/- 75/- 102/- 102/- 102/- 144/321 144/321 144/321 144/321 144/321 144/321
B3 [mm] - - - - - 355 355 355 355 355 355
C1 ★ [mm] 80/- 80/- 80/- 80/- 80/- 144/435 144/435 144/435 144/435 144/435 144/435
C5 ★ [mm] 110 110 140 140 140 220/46 220/46 220/46 220/46 220/46 220/46
C6 [mm] - - - - - 175 175 175 175 175 175
L1 [mm] 220 220 280 280 280 440 440 440 440 440 440
H1 [mm] 68 68 79 79 79 100 100 100 100 100 100
H2 [mm] 125 125 137 137 147 156 184 184 223 223 253
1~/3~ TP [mm] -/395 -/395 -/447 -/517 -/507 -/577 -/619 -/656 -/714 -/702 -/824
H3
1~/3~ TPE [mm] - - - - - -/530 -/618 -/618 -/712 -/736 -/759
H4 [mm] - - - - - - - - - - 35
M [mm] M12 M12 M12 M12 M12 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
139
24
DN 40
2-pole, PN 6, 10, 16, 25
Performance curves and technical data
+ +
>P@ >P@
7373(
7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>OV@ 4>OV@
Y>PV@ Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
140
24
DN 40
2-pole, PN 6, 10, 16, 25
TP 40 -80/2 -160/2 -240/2 -270/2 -330/2 -390/2 -400/2 -460/2 -530/2 -690/2 -820/2 -920/2
TPD - - - - - - ● ● ● ● ● ●
TPE - - - - - - ● ● ● ● ● ●
TPED - - - - - - - - - - - -
Series 200 200 200 200 200 200 300 300 300 300 300 300
1~ TP - - - - - - - - - - - -
3~ TP 71 80 90 90 90 100 112 132 132 160 160 160
IEC size
1~ TPE - - - - - - - - - - - -
3~ TPE - - - - - - 112 132 132 160 160 160
1~/3~ TP [kW] -/0.55 -/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5
P2
1~/3~ TPE [kW] - - - - - - -/4 -/5.5 -/7.5 -/11 -/15 -/18.5
PN PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 40 40 40 40 40 40 40 40 40 40 40 40
1~/3~ TP [mm] -/142 -/142 -/142 -/178 -/178 -/178 -/220 -/220 -/260 -/314 -/314 -/314
AC
1~/3~ TPE [mm] - - - - - - -/191 -/191 -/255 -/255 -/314 -/314
1~/3~ TP [mm] -/109 -/109 -/109 -/110 -/110 -/110 -/134 -/134 -/159 -/204 -/204 -/204
AD
1~/3~ TPE [mm] - - - - - - -/201 -/201 -/237 -/237 -/308 -/308
AE 1~/3~ TPE [mm] - - - - - - 146 146 173 173 210 210
AF 1~/3~ TPE [mm] - - - - - - 146 146 173 173 210 210
P [mm] - - - - - - 250 300 300 350 350 350
B1 ★ [mm] 85/- 75/- 101/- 102/- 102/- 102/- 150/325 150/325 150/325 150/325 150/325 150/325
B2 ★ [mm] 75/- 75/- 101/- 102/- 102/- 102/- 147/325 147/325 147/325 147/325 147/325 147/325
B3 [mm] - - - - - - 355 355 355 355 355 355
C1 ★ [mm] 120/- 80/- 80/- 120/- 120/- 120/- 144/435 144/435 144/435 144/435 144/435 144/435
C5 ★ [mm] 125 125 125 160 160 160 220/108 220/108 220/108 220/108 220/108 220/108
C6 [mm] - - - - - - 175 175 175 175 175 175
L1 [mm] 250 250 250 320 320 320 440 440 440 440 440 440
H1 [mm] 67 67 68 68 68 68 110 110 110 110 110 110
H2 [mm] 132 139 144 150 150 160 184 223 223 253 253 253
1~/3~ TP [mm] -/390 -/437 -/513 -/500 -/540 -/564 -/666 -/724 -/724 -/834 -/834 -/878
H3
1~/3~ TPE [mm] - - - - - - -/628 -/722 -/746 -/769 -/834 -/878
H4 [mm] - - - - - - - - - 35 35 35
M [mm] M12 M12 M12 M12 M12 M12 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
141
24
DN 50
2-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM02 5038 2115
4>OV@
Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
142
24
DN 50
2-pole, PN 6, 10, 16, 25
143
24
DN 50
2-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM02 5039 2115
4>OV@
Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
144
24
DN 50
2-pole, PN 6, 10, 16, 25
145
24
DN 65
2-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM02 5040 2115
4>OV@
Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
146
24
DN 65
2-pole, PN 6, 10, 16, 25
147
24
DN 65
2-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM02 5041 2115
4>OV@
Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
148
24
DN 65
2-pole, PN 6, 10, 16, 25
149
24
DN 80
2-pole, PN 6, 10, 16, 25
Performance curves and technical data
+ +
>P@ >P@
7373(
7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM02 5042 2115
4>OV@ 4>OV@
Y>PV@ Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
150
24
DN 80
2-pole, PN 6, 10, 16, 25
TP 80 -160/2 -200/2 -240/2 -290/2 -330/2 -400/2 -480/2 -530/2 -640/2 -750/2
TPD - ● ● ● ● ● ● ● ● ●
TPE - ● ● ● ● ● ● ● - -
TPED - - - - - - - - - -
Series 200 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - - -
3~ TP 100 112 132 132 160 160 160 180 200 200
IEC size
1~ TPE - - - - - - - - - -
3~ TPE - 112 132 132 160 160 160 180 - -
1~/3~ TP [kW] -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 -/30 -/37
P2
1~/3~ TPE [kW] - -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 - -
PN PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 80 80 80 80 80 80 80 80 80 80
1~/3~ TP [mm] -/175 -/220 -/220 -/260 -/314 -/314 -/314 -/314 -/396 -/396
AC
1~/3~ TPE [mm] - -/191 -/191 -/255 -/255 -/314 -/314 -/314 - -
1~/3~ TP [mm] -/110 -/134 -/134 -/159 -/204 -/204 -/204 -/204 -/315 -/315
AD
1~/3~ TPE [mm] - -/201 -/201 -/237 -/237 -/308 -/308 -/308 - -
AE 1~/3~ TPE [mm] - 146 146 173 173 210 210 210 - -
AF 1~/3~ TPE [mm] - 146 146 173 173 210 210 210 - -
P [mm] - 250 300 300 350 350 350 350 400 400
B1 ★ [mm] 125/- 125/260 125/260 125/260 176/366 176/366 187/416 187/416 187/416 187/416
B2 ★ [mm] 100/- 119/290 119/290 119/290 144/354 144/354 162/405 162/405 162/405 162/405
B3 [mm] - 340 340 340 400 400 470 470 470 470
C1 ★ [mm] 160/- 144/420 144/420 144/420 144/480 144/480 144/550 144/550 144/550 144/550
C5 ★ [mm] 180 180/78 180/78 180/78 220/93 220/93 250/133 250/133 250/133 250/133
C6 [mm] - 175 175 175 175 175 175 175 175 175
L1 [mm] 360 360 360 360 440 440 500 500 500 500
H1 [mm] 97 105 105 105 115 115 115 115 115 115
H2 [mm] 174 204 243 243 273 273 273 273 273 273
1~/3~ TP [mm] -/606 -/681 -/739 -/727 -/859 -/859 -/903 -/903 -/951 -/976
H3
1~/3~ TPE [mm] - -/643 -/713 -/737 -/794 -/859 -/903 -/929 - -
H4 [mm] - - - - 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
151
24
DN 100
2-pole, PN 6, 10, 16, 25
Performance curves and technical data
+ +
>P@ >P@
7373(
7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM02 8770 2115
4>OV@ 4>OV@
Y>PV@ Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
152
24
DN 100
2-pole, PN 6, 10, 16, 25
153
24
DN 100
2-pole, PN 6, 10, 16, 25
Performance curves and technical data
H
[m]
180 TP, TPE 100
170 -1510/2 60 Hz
160
150
-1360/2
140
130 -1200/2
120 -1040/2
110
-940/2
100
90 -760/2
80
70
60
50
0 50 100 150 200 250 300 350 400 Q [m³/h]
P2
[kW]
-1510/2
200
160 -1360/2
-1200/2
120
-1040/2
-940/2
80 -760/2
40
0
0 50 100 150 200 250 300 350 400 Q [m³/h]
NPSH
[m]
28
-1040/2
24
-940/2
20
16 -760/2
12
-1200/2, -1360/2, -1510/2
8
4
0
0 50 100 150 200 250 300 350 400 Q [m³/h]
Eta
[%]
80
75 -1510/2
70 -760/2
-940/2 -1360/2
65 -1200/2
60 -1040/2
55
50
45
0 50 100 150 200 250 300 350 400 Q [m³/h]
TM06 6595 4717
0 2 4 6 8 10 12 14 v [m/s]
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
154
24
DN 100
2-pole, PN 6, 10, 16, 25
155
24
DN 32
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+ +
>P@ >P@
7373( 7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM02 5046 2115
4>OV@ 4>OV@
Y>PV@ Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
156
24
DN 32
4-pole, PN 6, 10, 16, 25
157
24
DN 40
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+ +
>P@ >P@
7373( 7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM02 5048 2115
4>OV@ 4>OV@
Y>PV@ Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
158
24
DN 40
4-pole, PN 6, 10, 16, 25
159
24
DN 50
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+ +
>P@ >P@
7373( 7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM02 5050 3315
4>OV@ 4>OV@
Y>PV@ Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
160
24
DN 50
4-pole, PN 6, 10, 16, 25
161
24
DN 65
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+ +
>P@ >P@
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@
>P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM02 5052 2115
4>OV@ 4>OV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
162
24
DN 65
4-pole, PN 6, 10, 16, 25
163
24
DN 80
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+ +
>P@ >P@
7373( 7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM02 5054 2115
4>OV@ 4>OV@
Y>PV@ Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
164
24
DN 80
4-pole, PN 6, 10, 16, 25
TP 80 -40/4 -80/4 -110/4 -150/4 -170/4 -230/4 -280/4 -340/4 -410/4 -460/4 -510/4
TPD - - ● ● ● ● ● ● ● ● ●
TPE - - - ● ● ● ● ● ● ● -
TPED - - - - - - - - - - -
Series 200 200 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - - - -
3~ TP 80 90 100 100 112 132 132 160 160 180 180
IEC size
1~ TPE - - - - - - - - - - -
3~ TPE - - - 112 112 132 160 160 160 180 -
1~/3~ TP [kW] -/0.75 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22
P2
1~/3~ TPE [kW] - - - -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/-
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 80 80 80 80 80 80 80 80 80 80 80
1~/3~ TP [mm] -/178 -/175 -/198 -/198 -/220 -/267 -/260 -/314 -/314 -/368 -/368
AC
1~/3~ TPE [mm] - - - -/191 -/191 -/255 -/255 -/314 -/314 -/314 -/-
1~/3~ TP [mm] -/110 -/135 -/120 -/120 -/134 -/167 -/159 -/204 -/204 -/286 -/268
AD
1~/3~ TPE [mm] - - - -/201 -/201 -/237 -/237 -/308 -/308 -/308 -/-
AE 1~/3~ TPE [mm] - - - 146 146 173 173 210 210 210 -/-
AF 1~/3~ TPE [mm] - - - 146 146 173 173 210 210 210 -/-
P [mm] 115 - 250 250 250 300 300 350 350 350 350
B1 ★ [mm] 130/- 135/- 176/366 187/416 187/416 243/491 243/491 243/491 243/491 243/491 243/491
B2 ★ [mm] 100/- 100/- 144/354 162/405 162/405 226/480 226/480 226/480 226/480 226/480 226/480
B3 [mm] - - 400 470 470 470 470 470 470 470 470
C1 ★ [mm] 160/- 160/- 144/480 144/550 144/550 230/550 230/550 230/550 230/550 230/550 230/550
C5 ★ [mm] 180 180 220/93 250/133 250/133 310/105 310/105 310/105 310/105 310/105 310/105
C6 [mm] - - 175 175 175 350 350 350 350 350 350
L1 [mm] 360 360 440 500 500 620 620 620 620 620 620
H1 [mm] 107 107 115 115 115 140 140 140 140 140 140
H2 [mm] 175 164 204 204 204 273 273 303 303 303 303
1~/3~ TP [mm] -/563 -/592 -/654 -/654 -/691 -/786 -/842 -/914 -/958 -/958 -/1049
H3
1~/3~ TPE [mm] - - - -/654 -/654 -/802 -/802 -/914 -/958 -/984 -/-
H4 [mm] - - - - - - 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
165
24
DN 100
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM02 5055 2915
4>OV@
Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
166
24
DN 100
4-pole, PN 6, 10, 16, 25
167
24
DN 100
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM02 8773 2115
4>OV@
Y>PV@
Note: All QH curves apply to single-head pumps. For further information, see page 125.
168
24
DN 100
4-pole, PN 6, 10, 16, 25
TP 100 -200/4 -240/4 -260/4 -290/4 -340/4 -350/4 -390/4 -470/4 -560/4
TPD ● ● ● ● ● ● ● ● -
TPE ● ● ● ● ● - ● - -
TPED - - - - - - - - -
Series 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - -
3~ TP 132 160 160 160 180 160 180 200 225S
IEC size
1~ TPE - - - - - - - -
3~ TPE 160 160 161 160 180 180 - -
1~/3~ TP [kW] -/7.5 -/11 -/11 -/15 -/18.5 -/22 -/22 -/30 -/37
P2
1~/3~ TPE [kW] -/7.5 -/11 -/11 -/15 -/18.5 - -/22 - -
PN PN16/25 PN16/25 PN 16 PN16/25 PN16/25 PN 16 PN16/25 PN16/25 PN 25
Tmin;Tmax [°C] [-40;150] [-40;150] [-25;120] [-40;150] [-40;150] [-25;120] [-40;150] [-40;150] [-40;150]
D1 [mm] 100 100 100 100 100 100 100 100 100
1~/3~ TP [mm] -/260 -/314 -/314 -/314 -/368 -/363 -/368 -/408 -/442
AC
1~/3~ TPE [mm] -/255 -/314 -/314 -/314 -/314 - -/350 - -
1~/3~ TP [mm] -/159 -/204 -/204 -/204 -/286 -/262 -/286 -/315 -/325
AD
1~/3~ TPE [mm] -/237 -/308 -/308 -/308 -/308 - -/439 - -
AE 1~/3~ TPE [mm] 173 210 210 210 210 - 164 - -
AF 1~/3~ TPE [mm] 173 210 210 210 210 - 164 - -
P [mm] 300 350 350 350 350 350 350 400 450
B1 ★ [mm] 290/579 290/579 201/443 290/579 290/579 290/579 290/579 290/579 281/-
B2 ★ [mm] 249/561 249/561 173/429 249/561 249/561 249/561 249/561 249/561 246/-
B3 [mm] 600 600 500 600 600 600 600 600 -
C1 ★ [mm] 230/680 230/680 230/550 230/680 230/680 230/680 230/680 230/680 230
C5 ★ [mm] 335/110 335/110 275/110 335/110 335/110 335/110 335/110 335/110 335
C6 [mm] 350 350 230 350 350 350 350 350 -
L1 [mm] 670 670 550 670 670 670 670 670 670
H1 [mm] 175 175 140 175 175 175 175 175 175
H2 [mm] 254 308 307 308 308 308 308 308 313
1~/3~ TP [mm] -/858 -/954 -/826 -/998 -/998 -/1093 -/1079 -/1128 -/1150
H3
1~/3~ TPE [mm] -/842 -/954 -/826 -/998 -/998 - -/1008 - -
H4 [mm] - 35 35 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
169
24
DN 125
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM06 3851 2115
4>OV@
Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
170
24
DN 125
4-pole, PN 6, 10, 16, 25
Technical data
171
24
DN 125
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+ +
>P@ >P@
7373( 7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM02 8774 2115
4>OV@ 4>OV@
Y>PV@ Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
172
24
DN 125
4-pole, PN 6, 10, 16, 25
TP 125 -130/4 -160/4 -200/4 -230/4 -220/4 -280/4 -340/4 -365/4 -420/4 -480/4 -550/4 -580/4
TPD ● ● ● ● - ● ● ● ● ● - -
TPE ● ● ● ● ● ● - - ● ● - -
TPED - - - - - - - - - - - -
Series 300 300 300 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - - - - -
3~ TP 132 132 160 160 160 180 180 200 200 225 225M 225M
IEC size
1~ TPE - - - - - - - - - - - -
3~ TPE 132 132 160 160 160 180 - - - - - -
1~/3~ TP [kW] -/5.5 -/7.5 -/11 -/15 -/15 -/18.5 -/22 -/30 -/30 -/37 -/45 -/55
P2
1~/3~ TPE [kW] -/5.5 -/7.5 -/11 -/15 -/15 -/18.5 - - - - - -
PN PN 16 PN 16 PN 16 PN 16 PN 25 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140] [-40;150] [-40;150]
D1 [mm] 125 125 125 125 125 125 125 125 125 125 125 125
1~/3~ TP [mm] -/267 -/267 -/314 -/314 -/314 -/368 -/368 -/408 -/408 -/449 -/442 -/495
AC
1~/3~ TPE [mm] -/255 -/255 -/314 -/314 -/314 -/314 - - - - - -
1~/3~ TP [mm] -/167 -/167 -/204 -/204 -/204 -/286 -/286 -/315 -/315 -/338 -/325 -/392
AD
1~/3~ TPE [mm] -/237 -/237 -/308 -/308 -/308 -/308 - - - - - -
AE 1~/3~ TPE [mm] -/173 -/173 -/210 -/210 -/210 -/210 - - - - - -
AF 1~/3~ TPE [mm] -/173 -/173 -/210 -/210 -/210 -/210 - - - - - -
P [mm] 300 300 350 350 350 350 350 350 400 450 450 550
B1 ★ [mm] 250/537 250/537 250/537 250/537 244/537 244/537 244/537 244/537 273/568 273/568 271/- 271/-
B2 ★ [mm] 220/518 220/518 220/518 220/518 220/516 220/516 220/516 220/516 236/545 236/545 243/- 243/-
B3 [mm] 600 600 600 600 600 600 600 600 600 600 - -
C1 ★ [mm] 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230 230
C5 ★ [mm] 310/84 310/84 310/84 310/84 400/175 400/175 400/175 400/175 400/175 400/175 400 400
C6 [mm] 300 300 300 300 -/350 -/350 -/350 -/350 350 350 - -
L1 [mm] 620 620 620 620 800 800 800 800 800 800 800 800
H1 [mm] 215 215 215 215 215 215 215 215 215 215 215 215
H2 [mm] 283 283 283 312.5 315 315 315 315 312 342 348 353
1~/3~ TP [mm] -/870 -/908 -/870 -/1042.5 -/1105 -/1088 -/1118 -/1166 -/1163 -/1205 -/1271 -/1384
H3
1~/3~ TPE [mm] -/887 -/887 -/873 -/1042.5 -/1045 -/1071 - - - - - -
H4 [mm] - 35 35 35 35 35 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
173
24
DN 150
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM06 3852 2115
4>OV@
Y>PV@
Note: All QH curves apply to single-head pumps. For further information, see page 125.
174
24
DN 150
4-pole, PN 6, 10, 16, 25
175
24
DN 150
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM02 8776 2115
4>OV@
Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
176
24
DN 150
4-pole, PN 6, 10, 16, 25
177
24
DN 150
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM03 4652 2115
4>OV@
Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.
178
24
DN 150
4-pole, PN 6, 10, 16, 25
Technical data
179
24
DN 150
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM05 0539 2115
Y>PV@
180
24
DN 150
4-pole, PN 6, 10, 16, 25
Technical data
181
24
DN 200
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
TP 200-XXX/4
+ +
>P@ >P@
7373(
7373(
+] +]
4>PñK@ 4>PñK@
3 3
>N:@ >N:@
4>PñK@ 4>PñK@
136+ 136+
>P@ >P@
4>PñK@ 4>PñK@
(WD (WD
>@ >@
4>PñK@ 4>PñK@
TM05 0541 2115
4>OV@ 4>OV@
Y>PV@ Y>PV@
182
24
DN 200
4-pole, PN 6, 10, 16, 25
TP 200 -80/4 -110/4 -140/4 -190/4 -210/4 -250/4 -280/4 -320/4 -360/4 -390/4
TPD - - - - - - - - - -
TPE ● ● ● ● - - - - - -
TPED - - - - - - - - - -
Series 300 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - - -
3~ TP 132 160 160 180 180 200 225 225 250 280
IEC size
1~ TPE - - - - - - - - - -
3~ TPE 132 160 160 180 - - - - - -
1~/3~ TP [kW] -/7.5 -/11 -/15 -/18.5 -/22 -/30 -/37 -/45 -/55 -/75
P2
1~/3~ TPE [kW] -/7.5 -/11 -/15 -/18.5 - - - - - -
PN PN16 PN16 PN16 PN16 PN16 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140]
D1 [mm] 200 200 200 200 200 200 200 200 150 150
1~/3~ TP [mm] -/267 -/320 -/320 -/368 -/368 -/408 -/449 -/449 -/497 -/551
AC
1~/3~ TPE [mm] -/255 -/314 -/314 -/314 - - - - - -
1~/3~ TP [mm] -/167 -/197 -/197 -/286 -/286 -/315 -/338 -/338 -/410 -/433
AD
1~/3~ TPE [mm] -/237 -/308 -/308 -/308 - - - - - -
AE 1~/3~ TPE [mm] -/173 -/210 -/210 -/210 - - - - - -
AF 1~/3~ TPE [mm] -/173 -/210 -/210 -/210 - - - - - -
P [mm] 300 350 350 350 350 400 450 450 550 550
B1 ★ [mm] 296/- 363/- 363/- 363/- 363/- 348/- 348/- 348/- 348/- 348/-
B2 ★ [mm] 237/- 283/- 283/- 283/- 283/- 288/- 288/- 288/- 288/- 288/-
L1 [mm] 900 900 900 900 900 900 900 900 900 900
H1 [mm] 280 280 280 280 280 280 280 280 280 280
H2 [mm] -/336 -/336 -/336 -/336 -/336 -/331 -/361 -/361 -/361 -/361
1~/3~ TP [mm] -/1026 -/1094 -/1134 -/1130 -/1160 -/1256 -/1298 -/1358 -/1397 -/1470
H3
1~/3~ TPE [mm] -/975 -/1094 -/1134 -/1174 - - - - - -
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
183
24
DN 200
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
TP 200-XXX/4
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM03 8592 2115
Y>PV@
184
24
DN 200
4-pole, PN 6, 10, 16, 25
Technical data
185
24
DN 200
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
TP 200-XXX/4
+
>P@
7373(
+]
4>PñK@
3
>N:@
4>PñK@
136+
>P@
4>PñK@
(WD
>@
4>PñK@
TM03 8593 2115
Y>PV@
186
24
DN 200
4-pole, PN 6, 10, 16, 25
187
24
DN 300
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
TP 300-XXX/4
H H
[m] [m]
TP, TPE 300 TP, TPE 300
70 80
-630/4 60 Hz -750/4 60 Hz
60 -550/4 70
-640/4
-440/4
50 60
-370/4
40 50
-360/4
-270/4
30 40
-230/4
20 30
10 20
0 10
0 200 400 600 800 1000 1200 Q [m³/h] 0 200 400 600 800 1000 1200 1400 Q [m³/h]
P2 P2
[kW] [kW]
160 -750/4
-630/4 240
140
-550/4 200 -640/4
120
-440/4
100 160
-370/4
80
-360/4 120
60
-270/4 80
40 -230/4
20 40
0 200 400 600 800 1000 1200 Q [m³/h] 0 200 400 600 800 1000 1200 1400 Q [m³/h]
NPSH NPSH
[m] [m]
-370/4
18 18
-640/4
16 -750/4
-270/4 16
14
-230/4 14
12
12
10
10
8 -630/4
-550/4 8
6
-440/4
-360/4
4 6
0 200 400 600 800 1000 1200 Q [m³/h] 0 200 400 600 800 1000 1200 1400 Q [m³/h]
Eta Eta
[%] [%]
90 90
-360/4
85 85
-750/4
80 80
-630/4
75 75
-640/4
70 70
-550/4
65 -440/4
-230/4 -370/4
65
60 -270/4 60
55 55
50 50
0 200 400 600 800 1000 1200 Q [m³/h] 0 200 400 600 800 1000 1200 1400 Q [m³/h]
TM06 6596 4717
0 1 2 3 4 5 v [m/s] 0 1 2 3 4 5 6 v [m/s]
188
24
DN 300
4-pole, PN 6, 10, 16, 25
Technical data
TP 300 -230/4 -270/4 -360/4 -370/4 -440/4 -550/4 -630/4 -640/4 -750/4
TPD - - - - - - - - -
TPE - - - - - - - - -
TPED - - - - - - - - -
Series 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - -
3~ TP 225M 250M 280S 280M 315S 315M 315M 315L 315L
IEC size
1~ TPE - - - - - - - - -
3~ TPE - - - - - - - - -
3~ TP [kW] -/45 -/55 -/75 -/90 -/110 -/132 -/160 -/200 -/250
P2
3~ TPE [kW] - - - - - - - - -
PN PN16/25 PN16/25 PN16/25 PN16/25 PN16/25 PN16/25 PN16/25 PN16/25 PN16/25
Tmin;Tmax [°C] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150]
D1 [mm] 300 300 300 300 300 300 300 300 300
1~/3~ TP [mm] -/442 -/495 -/555 -/555 -/610 -/610 -/610 -/610 -/702
AC
1~/3~ TPE [mm] - - - - - - - - -
1~/3~ TP [mm] -/325 -/392 -/432 -/432 -/495 -/495 -/495 -/495 -/619
AD
1~/3~ TPE [mm] - - - - - - - - -
P [mm] 450 550 550 550 660 660 660 660 660
B1 [mm] 438/- 438/- 438/- 460/- 460/- 460/- 460/- 438/- 438/-
B2 [mm] 320/- 320/- 320/- 345/- 345/- 345/- 345/- 338/- 338/-
B5 [mm] 663 663 663 663 663 663 663 666 666
C3 [mm] 570 570 570 570 570 570 570 570 570
C9 [mm] 1150 1150 1150 1150 1150 1150 1150 1150 1150
L1 [mm] 1240 1240 1240 1240 1240 1240 1240 1240 1240
H1 [mm] 348 348 348 317 317 317 317 340 340
H2 [mm] 423 423 423 443 468 468 468 455 460
H3 [mm] -/1480 -/1588 -/1591 -/1690 -/1717 -/1877 -/1877 -/2027 -/2040
∅ [mm] 20 20 20 20 20 20 20 20 20
189
24
DN 350
4-pole, PN 6, 10, 16, 25
Performance curves and technical data
TP 350-XXX/4
H
[m]
65 -680/4 TP, TPE 350
60 60 Hz
-540/4
55
-450/4
50
45 -400/4
40
35
30
25
20
15
10
0 400 800 1200 1600 Q [m³/h]
P2
[kW]
-680/4
240
200 -540/4
160 -450/4
120 -400/4
80
40
0 400 800 1200 1600 Q [m³/h]
NPSH
[m]
24
-540/4, -680/4
20
-450/4
16
-400/4
12
8
0 400 800 1200 1600 Q [m³/h]
Eta
[%]
90
85
-680/4
80
75 -540/4
-450/4
70
65
-400/4
60
55
50
0 400 800 1200 1600 Q [m³/h]
TM06 6623 4717
0 1 2 3 4 5 v [m/s]
190
24
DN 350
4-pole, PN 6, 10, 16, 25
Technical data
191
25 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
192
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
25
TP, TPD, TPE, 2-pole, PN 6, 10, 16, 25
193
25 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Weights and shipping volume
Connection Weights
Shipping volume [m3] ★
Pump type Net [kg] ★ Gross [kg] ★
D1D D1 S
TP/TPD TPE TP/TPD TPE TP/TPD TPE
TP, TPD 100-230/2 DN 100 DN 100 110/230 108 124/280 139 0.7248 / 1.524 1.120
TP, TPD 100-300/2 DN 100 DN 100 155/319 133 177/369 164 0.7248 / 1.524 1.120
TP, TPD 100-370/2 DN 100 DN 100 168/344 193 190/394 214 0.9696 / 1.524 0.9696
TP, TPD 100-350/2 DN 100 DN 100 200/394 238 201/445 240 0.7248 / 1.524 0.7248
TP, TPD 100-380/2 DN 100 DN 100 230/455 252 231/505 254 0.9696 / 1.524 0.9696
TP, TPD 100-530/2 DN 100 DN 100 389/775 - 430/833 - 0.7973 / 1.800 -
TP, TPD 100-630/2 DN 100 DN 100 405/808 - 447/865 - 0.7973 / 1.800 -
TP, TPD 100-700/2 DN 100 DN 100 428/854 - 444/927 - 0.7973 / 1.800 -
TP 100-760/2 DN 100 DN 100 775/- - 895/- - 2.05 / - -
TP 100-940/2 DN 100 DN 100 874/- - 994/- - 2.05 / - -
TP 100-1040/2 DN 100 DN 100 1065/- - 1185/- - 2.05 / - -
TP 100-1200/2 DN 100 DN 100 1220/- - 1340/- - 2.05 / - -
TP 100-1360/2 DN 100 DN 100 1360/- - 1480/- - 2.05 / - -
TP 100-1510/2 DN 100 DN 100 1560/- - 1680/- - 2.05 / - -
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
194
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
25
195
25 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Weights and shipping volume
Connection Weights
Shipping volume [m 3] ★
Pump type Net [kg] ★ Gross [kg] ★
D1D D1S
TP/TPD TPE TP/TPD TPE TP/TPD TPE
TP 200-80/4 DN 200 DN 200 322/- 282 495/- 437 2.3 / - 2.3
TP 200-110/4 DN 200 DN 200 343/- 362 516/- 535 2.3 / - 2.3
TP 200-140/4 DN 200 DN 200 369/- 388 542/- 561 2.3 / - 2.3
TP 200-190/4 DN 200 DN 200 389/- 392 562/- 565 2.3 / - 2.3
TP 200-210/4 DN 200 DN 200 412/- - 585/- - 2.3 / - -
TP 200-250/4 DN 200 DN 200 480/- - 678/- - 3.1 / - -
TP 200-280/4 DN 200 DN 200 578/- - 776/- - 3.1 / - -
TP 200-320/4 DN 200 DN 200 618/- - 816/- - 3.1 / - -
TP 200-360/4 DN 200 DN 200 760/- - 993/- - 4.6 / - -
TP 200-390/4 DN 200 DN 200 875/- - 1098/- - 4.6 / - -
TP 200-400/4 DN 200 DN 200 1028/- - 1133/- - 3.1 / - -
TP 200-430/4 DN 200 DN 200 925/- - 1110/- - 3.1 / - -
TP 200-440/4 DN 200 DN 200 1049/- - 1269/- - 4.6 / - -
TP 200-490/4 DN 200 DN 200 1043/- - 1228/- - 3.1 / - -
TP 200-500/4 DN 200 DN 200 1229/- - 1449/- - 4.6 / - -
TP 200-540/4 DN 200 DN 200 1144/- - 1364/- - 4.6 / - -
TP 200-600/4 DN 200 DN 200 1325/- - 1563/- - 4.6 / - -
TP 200-680/4 DN 200 DN 200 1500/- - 1720/- - 4.6 / - -
TP 200-770/4 DN 200 DN 200 1642/- - 1862/- - 4.6 / - -
TP 300-230/4 DN 300 DN 300 905/- - 1035/- - 2.82 / - -
TP 300-270/4 DN 300 DN 300 1065/- - 1195/- - 2.82 / - -
TP 300-360/4 DN 300 DN 300 1175/- - 1305/- - 2.82 / - -
TP 300-370/4 DN 300 DN 300 1330/- - 1490/- - 3.24 / - -
TP 300-440/4 DN 300 DN 300 1510/- - 1670/- - 3.24 / - -
TP 300-550/4 DN 300 DN 300 1665/- - 1825/- - 3.24 / - -
TP 300-630/4 DN 300 DN 300 1805/- - 1965/- - 3.24 / - -
TP 300-640/4 DN 300 DN 300 1965/- - 2285/- - 6.06 / - -
TP 300-750/4 DN 300 DN 300 2155/- - 2475/- - 6.46 / - -
TP 350-400/4 DN 350 DN 350 1865/- - 2115/- - 5.26 / - -
TP 350-450/4 DN 350 DN 350 2005/- - 2255/- - 5.26 / - -
TP 350-540/4 DN 350 DN 350 2210/- - 2530/- - 6.46 / - -
TP 350-680/4 DN 350 DN 350 2405/- - 2725/- - 6.46 / - -
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.
196
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
26
197
26 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Minimum efficiency index
198
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
26
199
26 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Minimum efficiency index
TP, PN 25
P2 Nominal impeller size /
PN 25 Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TP Series 300, PN 25 All *
200
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
27. Accessories
Accessories
Counterflanges
A flange kit consists of two steel flanges, two gaskets of asbestos-free material IT 200, and the requisite number of
bolts.
Pipe Product
Counterflange Pump type Description Rated pressure
connection number
ø19
Rp 1¼ 32 mm,
For welding 10 bar, EN 1092-2 539704
nominal
TP, TPE 32
TPD 32
40 mm,
For welding 10 bar, EN 1092-2 539702
nominal
TP, TPE 40
TPD 40
TM03 0479 5204
ø122
Threaded 16 bar, EN 1092-2 Rp 2 1/2 559801
ø145
Threaded For welding ø185
65 mm,
For welding 16 bar, EN 1092-2 559802
nominal
80 mm,
For welding 6 bar, EN 1092-2 569901
nominal
Rp 3 ø19
80 mm,
For welding 16 bar, EN 1092-2 569801
nominal
201
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Accessories
Pipe Product
Counterflange Pump type Description Rated pressure
connection number
100 mm,
For welding 6 bar, EN 1092-2 579902
nominal
Rp 4 ø19
100 mm,
For welding 16 bar, EN 1092-2 579802
nominal
ø23
150 mm,
For welding 10 bar, EN 1092-2 S1111600
nominal
TP, TPE 150
TM03 0485 5204
TPD 150
ø212 150 mm,
For welding 16 bar, EN 1092-2 S1111600
ø240 nominal
For welding ø285
202
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Adapter flanges for various port-to-port lengths
Accessories
Diameter D Pitch circle diameter D1
Height (H) Product number
DN [mm] [mm] Adapter flange
[mm]
PN 6 PN 10/16 PN 6 PN 10/16 PN 6 PN 10/16
1 x 220 - - 90 100 D1
98848068 98849069
H
1 x 120 - - 90 100 98387529 98387530
32
1 x 60 70 78 - - 98387527 98387528
D
H
1 x 30 70 78 - - 98387531 98387588
D1
H
1 x 190 - - 100 110 98387592 98387593
H
50 1 x 60 - - 110 125 549924 549824
D1
65
D
D1
D1
203
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Note: TPE2, TPE3 pumps are not designed to be Pump type Hexagon head screws
Product
supplied with a base plate. Base plates are supplied as number
standard with TP, TPE pumps with 11 kW motors and TPE2 D, TPE3 D 32 99150053
above. TPE2 D, TPE3 D 40 99150054
TPE2 D, TPE3 D 50 3 x M12 x 40 mm 99150055
Some of the TP Series 300 pumps are provided with TPE2 D, TPE3 D 65
mounting feet and cannot be supplied with a base 99150056
TPE2 D, TPE3 D 80
plate. See fig. 96. TPE2 D, TPE3 D 100 3 x M12 x 16 mm 99150057
380 C
290 35
290
380
A
7x 14
20
TM06 1083 1614
380 151
290 35
290
380
7x 14
20
380
290 138
81 79 35
380
290
7x 14
Dimensions [mm]
Pump type Product number
A B C
TPE2 D, TPE3 D 32 0 69 123 99150053
TPE2 D, TPE3 D 40 5 45 124 99150054
TPE2 D, TPE3 D 50 8 18 130 99150055
TPE2 D, TPE3 D 65 50 0 132 99150056
TPE2 D, TPE3 D 80 99150056
TPE2 D, TPE3 D 100 99150057
204
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
TP Series 200 TP, TPE Series 300
Accessories
Hexagon head Product Product
Pump type Pump type Hexagon head screws
screws number number
TP 32 TP, TPE 80-230/4
TP 40 TP, TPE 80-280/4
2 x M12 x 20 mm 96591246
TP 50 TP, TPE 80-340/4
TP 65-80/2, 65-160/2, 65-240/2 TP, TPE 80-410/4
TP 65-40/4, 65-80/4 TP, TPE 80-460/4
TP 80 2 x M16 x 30 mm 96591245 TP, TPE 80-510/4
TP 100 TP, TPE 100-350/2
TP, TPE 100-380/2
TP, TPE 100-530/2
Drawing Product number TP, TPE 100-630/2
2 x M16 x 30 mm 96536246
235
TP, TPE 100-700/2
195 35
TP 100-760/2
2xø18
TP 100-940/2
TP 100-1040/2
TP 100-1200/2
TP 100-1360/2
TP 100-1510/2
2xø14
96591246
TP, TPE 100-xx/4
160
195
80
96591245
2xø14 TP, TPE 125-xx/4
TM00 9835 0497
TP, TPE 65
TP, TPE 80-xx/2
TP 80-110/4 2 x M16 x 30 mm 00485031 2xø18
TP, TPE 80-150/4
TP, TPE 80-170/4
TP, TPE 100-230/2
TP, TPE 100-300/2
TP, TPE 100-370/2 TPD Series 300
Product
Product Pump type Hexagon head screws
Drawing number
number
TPD 32
235 TPD 40
195 35 TPD 50
2xø14 TPD 65
TPD 80-xx/2
TPD 80-110/4 4 x M16 x 30 mm 96489381
TPD 80-150/4
00485031 TPD 80-170/4
195
TPD 100-230/2
96
2xø18
TM00 3755 2602
TPD 100-300/2
TPD 100-370/2
4xø14 Product
144 Drawing
number
35
175 2xø18
96489381
TM02 5336 2602
47
67
300
2xø14
330
205
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
2xø18
96536247
TM02 8870 1004
230
47
67
355
2xø14
385
350
TM02 8871 1004
300 4xø18
96536248
47
67
475
2xø14
505
206
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Blanking flanges
Accessories
Normally used with twin-head pumps.
TPE2 D, TPE3 D
TPD 2-pole
207
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Accessories
TPD 4-pole
208
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Insulating kits
Accessories
Insulating kits are available for TPE2 and TPE3
pumps.
The insulating kit consists of two shells.
The insulating kit is tailored to the individual pump
model and encloses the entire pump housing, thus
providing optimum insulation.
209
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Sensors
Accessories
Flow sensors
210
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Temperature sensors
Accessories
Temperature sensor, TTA
Temperature sensor with Pt100 temperature sensor
fitted in a ∅6 x 100 mm measuring tube made of
stainless steel, DIN 1.4571 and a 4-20 mA sensor built
into a type B head DIN 43.729.
The connecting head is made of painted pressure
die-cast aluminium with Pg 16 screwed connection,
stainless screws and neoprene rubber gasket.
The sensor is built into the system either by means of
a cutting ring bush or by means of one of the two
matching protecting tubes ∅9 x 100 mm or ∅9 x 50
mm, respectively.
The protecting tube has G 1/2 connection.
Cutting ring bush or protecting tube must be ordered
separately.
Technical data
Type TTA (-25) 25 TTA (0) 25 TTA (0) 150 TTA (50) 100
Product number 96430194 96432591 96430195 96432592
Measuring range -25 to +25 °C 0 to +25 °C 0 to +150 °C 50 to +100 °C
Measuring accuracy According to IEC 751, class B, 0.3 °C at 0 °C
Response time, τ (0.9) in water Without protecting tube: 28 seconds
0.2 m/s With oil-filled protecting tube: 75 seconds
Enclosure class IP55
Output signal 4-20 mA
Supply voltage 8-35 VDC
EMC, electromagnetic Emission: According to EN 50081
compatibility Immunity: According to EN 50082
Accessories
Protecting tube
Type L
∅9 x 50 49
∅9 x 100 99
211
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Iout [mA]
ETSD1-04-020
The temperature sensors T1 and T2 measure the
20 ETSD1-04-050
temperature in their respective location at the same
time. Besides the temperature measurement, the T1 15
features an electronic unit calculating the temperature
difference between T1 and T2 and transmitting the 10
result as a 4-20 mA signal via a current amplifier.
ETSD1-04-020K045 ETSD1-04-050K045
Type ETSD1- 04- 020 K 045 Specification
+ ETSD2-K045 + ETSD2-K045
Product number 96409362 96409363 ETSD1- Reference temperature, T1.
Measuring range:
Temperature difference 0 to +20 °C 0 to +50 °C 04- 0 °C corresponds to 4 mA.
(T1-T2) or (T2-T1)
Supply voltage 15-30 VDC 020 20 °C corresponds to 20 mA.
Output signal 4-20 mA 050 50 °C corresponds to 20 mA.
Material in contact with liquid:
Measuring accuracy ± 0.3 % FS K
Stainless steel, DIN 1.4571.
Repeatability ± 1 % FS 045 Length of sensing element: 45 mm.
Response time, τ (0.9) 2 minutes
Ambient temperature -25 to +85 °C ETSD2- K 045 Specification
Operating temperature of
-25 to +105 °C ETSD2- Reference temperature, T2.
T1 and T2
Maximum distance Material in contact with liquid: Stainless steel,
300 m with screened cable K
between T1 and T2 DIN 1.4571.
Between T1 and T2: M12 x 1 plug (including
Electrical connection in kit), output signal with DIN 43650-A plug 045 Length of sensing element: 45 mm.
type
Storage temperature -45 to +125 °C
Short-circuit-proof Yes
Protected against polarity
Yes, up to 40 V
reversal
Materials in contact with
Stainless steel, DIN 1.4571
liquid
Enclosure class IP65
EMC, electromagnetic Emission: According to EN 50081
compatibility Immunity: According to EN 50082
212
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Installing the sensor
Accessories
Fit the two sensors in such a way that the sensing
elements are located in the middle of the flow of the
liquid to be measured.
140
54
SW
For tightening, use only the hexagon nut. 27
G 1/2
93
G 1/2
18
45
27
Pressure sensors
Sensors for boosting applications
Select the differential pressure sensor so that the maximum pressure of the sensor is higher than the maximum differential pressure of the pump.
Sensor interface
Grundfos Direct Sensors™, type SI 001 PSU, is an external power supply for the VFI, DPI
and other transmitters with 24 VDC supply voltage.
96915820
The power supply is used when the cable between transmitter and controller is more than
30 m long.
1)
For further information about the PSU sensor interface, see the installation and operating instructions "SI 001 PSU - sensor interface", publication
number 96944355, or quick guide, publication number 96944356.
213
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
MP 204 is an electronic motor protection for pumps. One unit covers all electrical motors from 3 to 999 A as well as
voltages from 100 to 480 VAC.
Installation of MP 204 is by means of screws onto a wall or back plate, or on a mounting rail.
Component Description Functions
Features
• Phase-sequence monitoring
• indication of current or temperature
• input for PTC sensor or thermal switch
• indication of temperature in °C or °F
• 4-digit, 7-segment display
• setting and status reading with Grundfos R100 remote
control
• setting and status reading via Grundfos GENIbus fieldbus.
MP 204 is an electronic motor protector and data Tripping conditions
collecting unit. Apart from protecting the motor, it • Overload
MP 204
can also send information to a CIU unit via • underload, dry running
GENIbus, like for instance: • temperature
• trip • missing phase
• warning • phase sequence
• energy consumption • overvoltage
• input power • undervoltage
• motor temperature. • power factor, cos φ
MP 204 protects the motor primarily by • current unbalance.
measuring the motor current by means of a true Warnings
RMS measurement. • Overload
The pump is protected secondarily by measuring • underload
the temperature with a Tempcon sensor, a • temperature
Pt100/Pt1000 sensor and a PTC sensor/thermal • overvoltage
switch. • undervoltage
MP 204 is designed for single- and three-phase • power factor, cos φ
motors. • run capacitor, single-phase operation
• starting capacitor, single-phase operation
• loss of communication in network
• harmonic distortion.
Learning function
TM03 0150 4204
Control MP 204
Control MP 204 is supplied as a plug-and-play control cabinet solution.
You can see the main switch and LED panel showing the power consumption on the front. Inside you find the MP 204
unit and optional communication interface units.
Digital input
Control MP 204 • Float switch or pressure relay, if no IO 112 is used.
Analog input
• Too high motor temperature, Tempcon
• thermistor/PTC, pump
The Control MP 204 control cabinets are • pressure sensor, 4-20 mA, with IO 112.
supplied with all necessary components. Three Relay output
types of control cabinets are available, • Pump alarm.
depending on functions and starting method. Communication
Control MP 204 is designed for installation in a • Grundfos Remote Management.
control cabinet for outdoor use. • GSM/GPRS
The control cabinets have a built-in main switch IO 112 is not supported.
and a thermal magnetic circuit breaker. • Modbus RTU wired
TM04 9512 4410
For more information about MP 204 and Control MP 204, see the data booklet "Control MP 204", publication number 97770915.
214
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Potentiometer MI 301
Accessories
MI 301 is a module with built-in infrared and radio
communication. Use MI 301 in conjunction with
Android or iOS-based smart devices with a Bluetooth
connection. MI 301 has rechargeable Li-ion battery
MI 204
TM05 7704 1513
215
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
modules
GrA 6118
GrA 6121
Fig. 105 Grundfos CIU communication interface unit Fig. 106 Grundfos CIM communication interface module
The CIU units enable communication of operating The CIM modules enable communication of operating
data, such as measured values and setpoints, between data, such as measured values and setpoints, between
TPE pumps and a building management system. The TPE pumps and a building management system. The
CIU unit incorporates a 24-240 VAC/VDC power CIM modules are add-on communication modules
supply module and a CIM module. You can mount the which are fitted in the terminal box of TPE pumps.
CIM module on a DIN rail or on a wall. For further information see section
For further information see section 14. Communication.
14. Communication. Note: CIM modules must be fitted by authorised
We offer the following CIU units: personnel.
Description Fieldbus protocol Product number
We offer the following CIM modules:
CIU 100 LON 96753735 Description Fieldbus protocol Product number
CIU 150 PROFIBUS DP 96753081
CIM 050 GENIbus 96824631
CIU 200 Modbus RTU 96753082
CIM 100 LON 96824797
CIU 250* GSM/GPRS 96787106
CIM 150 PROFIBUS DP 96824793
CIU 270* GRM 96898819
CIM 200 Modbus RTU 96824796
CIU 300 BACnet MS/TP 96893769
CIM 250* GSM/GPRS 96824795
CIU 500 Modbus TCP 96753894
CIU 270* GRM 96898815
CIU 500 PROFINET IO 96753894
CIM 300 BACnet MS/TP 96893770
* Antenna not included. See below. CIM 500 Modbus TCP 98301408
CIM 500 PROFINET 98301408
Antennas for CIU 250 and 270
* Antenna not included. See below.
Description Product number
Antennas for CIM 250 and 270
Antenna for roof 97631956
Antenna for desk 97631957 Description Product number
For further information about data communication via Antenna for roof 97631956
Antenna for desk 97631957
CIU units and fieldbus protocols, see the CIU
documentation available in Grundfos Product Center. For further information about data communication via
See page 224. CIM modules and fieldbus protocols, see the CIM
documentation available in Grundfos Product Center.
See page 224.
216
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
EMC filter
Accessories
EMC, electromagnetic compatibility to EN 61800-3
Motor [kW]
Emission/immunity
2-pole 4-pole
0.37 0.37
0.55 0.55
4.0 4.0
5.5 -
- 5.5 Emission:
The motors are category C3, corresponding to
7.5 7.5 CISPR11, group 2, class A, and may be
installed in industrial areas (second
11 11
environment).
15 15 If equipped with an external Grundfos EMC
filter, the motors are category C2,
18.5 18.5 corresponding to CISPR11, group 1, class A,
and may be installed in residential areas (first
22 - environment).
TM02 9198 1203
217
28 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
1
p NPSH R g – --- c 2 0,00001 – p + p [bar relative]
s 2 b d
218
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
28
TPE2, TPE2 D, TPE3, TPE3 D
219
28 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
p [bar] p [bar]
Pump type Pump type
20 °C 60 °C 90 °C 110 °C 120 °C 140 °C 150 °C 20 °C 60 °C 90 °C 110 °C 120 °C 140 °C 150 °C
TP 32-80/2 0.4 0.4 0.4 1.2 1.7 3.4 - TP 80-160/2 2.1 2.3 2.8 3.6 4.1 5.8 -
TP 32-160/2 0.4 0.6 1.1 1.9 2.4 4.1 - TP, TPD 80-200/2 0.5 0.7 1.2 1.9 2.5 4.1 -
TP 32-220/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 80-240/2 0.1 0.2 0.7 1.4 2.0 3.6 -
TP 32-260/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 80-290/2 0.1 0.3 0.8 1.5 2.1 3.7 -
TP 32-330/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 80-330/2 0.2 0.4 0.9 1.7 2.2 3.8 -
TP, TPD 32-300/2 0.1 0.1 0.1 0.7 1.2 2.8 - TP, TPD 80-400/2 0.6 0.8 1.3 2.1 2.6 4.2 -
TP, TPD 32-360/2 0.1 0.1 0.1 0.7 1.2 2.8 - TP, TPD 80-480/2 0.1 0.3 0.8 1.5 2.1 3.7 -
TP, TPD 32-450/2 0.1 0.1 0.1 0.7 1.2 2.8 - TP, TPD 80-530/2 0.2 0.4 0.9 1.6 2.1 3.8 -
TP, TPD 32-550/2 0.1 0.1 0.1 0.7 1.2 2.9 - TP, TPD 80-640/2 0.6 0.8 1.3 2.0 2.6 4.2 -
TP, TPD 32-680/2 0.1 0.1 0.2 0.9 1.5 3.1 - TP, TPD 80-750/2 0.6 0.8 1.3 2.0 2.6 4.2 -
TP, TPD 32-820/2 0.5 0.7 1.2 1.9 2.5 4.1 - TP, TPD 100-230/2 0.4 0.6 1.1 1.9 2.4 4.0 -
TP 40-80/2 0.1 0.3 0.8 1.6 2.1 3.8 - TP, TPD 100-300/2 0.2 0.4 0.9 1.6 2.2 3.8 -
TP 40-160/2 0.1 0.2 0.7 1.5 2.0 3.7 - TP, TPD 100-370/2 0.3 0.5 1.0 1.7 2.3 3.9 -
TP 40-240/2 0.4 0.6 1.1 1.9 2.4 4.1 - TP, TPD 100-350/2 0.9 1.1 1.6 2.3 2.9 4.5 -
TP 40-270/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 100-380/2 1.2 1.4 1.9 2.6 3.2 4.8 -
TP 40-330/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 100-530/2 1.7 1.9 2.4 3.2 3.7 5.3 -
TP 40-390/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 100-630/2 1.4 1.6 2.1 2.8 3.3 5.0 -
TP, TPD 40-400/2 0.1 0.1 0.1 0.9 1.4 3.1 - TP, TPD 100-700/2 3.0 3.2 3.7 4.4 5.0 6.6 -
TP, TPD 40-460/2 0.1 0.1 0.3 1.0 1.6 3.2 - TP 100-760/2 1.7 1.9 2.3 3.3 3.8 5.4 6.7
TP, TPD 40-530/2 0.1 0.1 0.4 1.1 1.7 3.3 - TP 100-940/2 1.6 1.8 2.2 3.2 3.7 5.3 6.6
TP, TPD 40-690/2 0.1 0.2 0.7 1.4 2.0 3.6 - TP 100-1040/2 1.6 1.8 2.2 3.2 3.7 5.3 6.6
TP, TPD 40-820/2 0.1 0.3 0.8 1.6 2.1 3.7 - TP 100-1200/2 1.9 2.1 2.5 3.5 4.0 5.6 6.9
TP, TPD 40-920/2 0.4 0.6 1.1 1.8 2.4 4.0 - TP 100-1360/2 1.8 2.0 2.4 3.4 3.9 5.5 6.8
TP 50-80/2 0.1 0.1 0.6 1.4 1.9 3.6 - TP 100-1510/2 1.8 2.0 2.4 3.4 3.9 5.5 6.8
TP 50-160/2 0.4 0.6 1.1 1.9 2.4 4.1 -
TP 50-240/2 0.3 0.5 1.0 1.8 2.3 4.0 -
TP, TPD 50-250/2 0.1 0.1 0.2 1.0 1.5 3.1 -
TP, TPD 50-300/2 0.1 0.1 0.3 1.0 1.6 3.2 -
TP, TPD 50-350/2 0.1 0.1 0.3 1.0 1.6 3.2 -
TP, TPD 50-410/2 0.1 0.1 0.4 1.1 1.6 3.3 -
TP, TPD 50-430/2 0.1 0.1 0.4 1.1 1.7 3.3 -
TP, TPD 50-530/2 0.1 0.1 0.5 1.3 1.8 3.5 -
TP, TPD 50-640/2 0.1 0.1 0.6 1.4 1.9 3.5 -
TP, TPD 50-720/2 0.1 0.3 0.8 1.6 2.1 3.7 -
TP, TPD 50-790/2 0.5 0.7 1.2 1.9 2.5 4.1 -
TP, TPD 50-880/2 0.8 1.0 1.5 2.2 2.8 4.4 -
TP 50-1050/2 1.1 1.3 1.8 2.5 3.1 4.7 -
TP 65-80/2 0.6 0.8 1.3 2.1 2.6 4.3 -
TP 65-160/2 1.1 1.3 1.8 2.6 3.1 4.8 -
TP 65-240/2 0.9 1.1 1.6 2.4 2.9 4.6 -
TP, TPD 65-200/2 0.1 0.1 0.3 1.0 1.5 3.2 -
TP, TPD 65-250/2 0.1 0.1 0.4 1.1 1.7 3.3 -
TP, TPD 65-340/2 0.1 0.1 0.2 1.0 1.5 3.1 -
TP, TPD 65-390/2 0.1 0.1 0.3 1.0 1.5 3.2 -
TP, TPD 65-480/2 0.1 0.1 0.3 1.0 1.6 3.2 -
TP, TPD 65-540/2 0.1 0.1 0.3 1.1 1.6 3.2 -
TP, TPD 65-630/2 0.1 0.1 0.4 1.1 1.7 3.3 -
TP, TPD 65-740/2 0.1 0.1 0.6 1.3 1.9 3.5 -
TP, TPD 65-910/2 0.1 0.2 0.7 1.5 2.0 3.6 -
TP, TPD 65-920/2 0.1 0.2 0.7 1.4 2.0 3.6 -
TP, TPD 65-1050/2 0.1 0.2 0.7 1.5 2.0 3.6 -
220
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
28
TP, TPE, TPD 4-pole, PN 6, 10, 16, 25
TP 32-40/4 0.1 0.1 0.1 0.9 1.4 3.1 - TP, TPD 125-480/4 0.1 0.1 0.5 1.2 1.8 3.4 4.7
TP 32-80/4 0.1 0.1 0.5 1.3 1.8 3.5 - TP 125-550/4 0.1 0.3 0.7 1.7 2.2 3.8 5.1
TP, TPD 32-120/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 125-580/4 0.1 0.3 0.7 1.7 2.2 3.8 5.1
TP, TPD 32-140/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 150-130/4 0.1 0.1 0.5 1.2 1.8 3.4 -
TP, TPD 32-190/4 0.1 0.1 0.1 0.8 1.4 3.0 - TP 150-160/4 0.1 0.2 0.7 1.5 2.0 3.6 -
TP 40-40/4 0.1 0.1 0.3 1.1 1.6 3.3 - TP 150-200/4 0.2 0.4 0.9 1.6 2.1 3.8 -
TP 40-80/4 0.1 0.1 0.2 1.0 1.5 3.2 - TP 150-220/4 0.3 0.5 1.0 1.7 2.3 3.9 -
TP, TPD 40-110/4 0.1 0.1 0.1 0.6 1.2 2.8 - TP, TPD 150-180/4 0.1 0.2 0.7 1.4 1.9 3.6 4.9
TP, TPD 40-150/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP, TPD 150-210/4 0.1 0.2 0.7 1.4 2.0 3.6 4.9
TP, TPD 40-180/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP, TPD 150-240/4 0.1 0.2 0.7 1.5 2.0 3.6 4.9
TP, TPD 40-230/4 0.1 0.1 0.1 0.8 1.3 3.0 - TP, TPD 150-300/4 0.1 0.3 0.8 1.5 2.1 3.7 5.0
TP 50-40/4 0.1 0.1 0.3 1.1 1.6 3.3 - TP, TPD 150-340/4 0.1 0.3 0.8 1.5 2.1 3.7 5.0
TP 50-80/4 0.1 0.1 0.3 1.1 1.6 3.3 - TP 150-360/4 0.3 0.5 1.0 1.8 2.3 4.0 5.3
TP, TPD 50-100/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 150-400/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 50-115/4 0.1 0.1 0.1 0.8 1.4 3.0 - TP 150-440/4 0.1 0.1 0.4 1.1 1.7 3.3 4.6
TP, TPD 50-130/4 0.1 0.1 0.1 0.9 1.4 3.0 - TP 150-480/4 0.1 0.1 0.5 1.3 1.8 3.4 4.7
TP, TPD 50-180/4 0.1 0.1 0.1 0.8 1.3 3.0 - TP 150-610/4 0.1 0.2 0.7 1.4 2.0 3.6 4.9
TP, TPD 50-240/4 0.1 0.1 0.2 0.9 1.5 3.1 - TP 150-700/4 0.1 0.3 0.8 1.5 2.1 3.7 5.0
TP, TPD 50-270/4 0.1 0.1 0.3 1.0 1.6 3.2 - TP 150-810/4 0.3 0.4 0.9 1.7 2.2 3.8 5.1
TP, TPD 50-340/4 0.1 0.2 0.7 1.4 2.0 3.6 - TP 150-960/4 0.4 0.6 1.1 1.8 2.3 3.8 5.1
TP 65-40/4 0.4 0.6 1.1 1.9 2.4 4.1 - TP 200-80/4 0.9 1.1 1.6 2.3 2.9 4.5 -
TP 65-80/4 0.7 0.9 1.4 2.2 2.7 4.4 - TP 200-110/4 0.5 0.6 1.1 1.9 2.4 4.0 -
TP, TPD 65-130/4 0.1 0.1 0.1 0.6 1.2 2.8 - TP 200-140/4 0.3 0.5 1.0 1.7 2.3 3.9 -
TP, TPD 65-150/4 0.1 0.1 0.1 0.6 1.2 2.8 - TP 200-190/4 0.2 0.4 0.9 1.6 2.2 3.8 -
TP, TPD 65-190/4 0.1 0.1 0.1 0.6 1.2 2.8 - TP 200-210/4 0.1 0.2 0.7 1.4 2.0 3.6 -
TP, TPD 65-230/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 200-250/4 0.9 1.0 1.5 2.3 2.8 4.4 5.7
TP, TPD 65-310/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 200-280/4 0.7 0.9 1.4 2.1 2.7 4.3 5.6
TP, TPD 65-330/4 0.1 0.1 0.1 0.3 0.8 2.5 - TP 200-320/4 0.6 0.8 1.3 2.0 2.6 4.2 5.5
TP 80-40/4 1.5 1.7 2.2 3.0 3.5 5.2 - TP 200-360/4 0.4 0.6 1.1 1.8 2.4 4.0 5.3
TP 80-80/4 1.6 1.8 2.3 3.1 3.6 5.3 - TP 200-390/4 0.3 0.5 1.0 1.7 2.2 3.9 5.2
TP, TPD 80-110/4 0.1 0.1 0.1 0.8 1.4 3.0 - TP 200-400/4 0.1 0.1 0.6 1.3 1.9 3.6 4.9
TP, TPD 80-150/4 0.1 0.1 0.1 0.8 1.3 2.9 - TP 200-430/4 0.1 0.1 0.6 1.4 1.9 3.6 4.9
TP, TPD 80-170/4 0.1 0.1 0.1 0.8 1.3 3.0 - TP 200-440/4 0.1 0.2 0.7 1.5 2.0 3.7 5.0
TP, TPD 80-230/4 0.1 0.1 0.3 1.0 1.6 3.2 - TP 200-490/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 80-280/4 0.1 0.1 0.2 1.0 1.5 3.1 - TP 200-500/4 0.2 0.4 0.9 1.6 2.2 3.9 5.2
TP, TPD 80-340/4 0.1 0.1 0.3 1.0 1.6 3.2 - TP 200-540/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 80-410/4 0.1 0.1 0.5 1.2 1.8 3.4 - TP 200-600/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 80-460/4 0.1 0.1 0.6 1.3 1.9 3.5 - TP 200-680/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 80-510/4 0.1 0.2 0.7 1.5 2.0 3.6 - TP 200-770/4 0.1 0.2 0.7 1.4 2.0 3.7 5.0
TP 100-40/4 1.4 1.6 2.1 2.9 3.4 5.1 - TP 300-230/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP 100-80/4 1.2 1.4 1.9 2.7 3.2 4.9 - TP 300-270/4 0.7 0.9 1.3 2.3 2.8 4.4 5.7
TP, TPD 100-100/4 0.1 0.1 0.2 0.9 1.5 3.1 - TP 300-360/4 0.7 0.9 1.3 2.3 2.8 4.4 5.7
TP, TPD 100-130/4 0.1 0.1 0.3 1.0 1.6 3.2 - TP 300-370/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP, TPD 100-150/4 0.1 0.1 0.6 1.3 1.9 3.5 - TP 300-440/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP, TPD 100-170/4 0.1 0.1 0.6 1.3 1.9 3.5 - TP 300-550/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP, TPD 100-200/4 0.1 0.1 0.4 1.1 1.7 3.3 4.6 TP 300-630/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP, TPD 100-240/4 0.1 0.1 0.6 1.3 1.9 3.5 4.8 TP 300-640/4 0.7 0.9 1.3 2.3 2.8 4.4 5.7
TP, TPD 100-260/4 0.6 0.8 1.3 2.1 2.7 4.3 5.6 TP 300-750/4 0.7 0.9 1.3 2.3 2.8 4.4 5.7
TP, TPD 100-290/4 0.5 0.7 1.2 2.0 2.5 4.1 5.4 TP 350-400/4 2.0 2.2 2.6 3.6 4.1 5.7 7.0
TP, TPD 100-340/4 0.6 0.8 1.3 2.0 2.6 4.2 5.5 TP 350-450/4 2.0 2.2 2.6 3.6 4.1 5.7 7.0
TP, TPD 100-350/4 0.2 0.4 0.9 1.7 2.3 3.9 5.2 TP 350-540/4 2.0 2.2 2.6 3.6 4.1 5.7 7.0
TP, TPD 100-390/4 0.7 0.9 1.4 2.1 2.7 4.3 5.6 TP 350-680/4 2.0 2.2 2.6 3.6 4.1 5.7 7.0
TP, TPD 100-470/4 0.9 1.1 1.6 2.3 2.9 4.5 5.8
TP 100-560/4 0.1 0.3 0.7 1.7 2.2 3.8 5.1
TP 125-80/4 0.1 0.1 0.1 0.8 1.4 3.0 -
TP 125-110/4 0.1 0.1 0.2 0.9 1.5 3.1 -
TP 125-135/4 0.1 0.1 0.3 1.1 1.6 3.3 -
TP, TPD 125-130/4 0.1 0.1 0.3 1.0 1.6 3.2 -
TP, TPD 125-160/4 0.1 0.1 0.3 1.1 1.6 3.2 -
TP, TPD 125-200/4 0.1 0.1 0.2 0.9 1.4 3.1 -
TP, TPD 125-230/4 0.1 0.1 0.4 1.1 1.7 3.3 -
TP 125-220/4 0.1 0.1 0.4 1.1 1.7 3.3 4.5
TP, TPD 125-280/4 0.1 0.1 0.4 1.1 1.7 3.3 4.5
TP, TPD 125-340/4 0.1 0.1 0.5 1.2 1.8 3.4 4.6
TP, TPD 125-365/4 0.3 0.5 1.0 1.7 2.3 3.9 5.2
TP, TPD 125-420/4 0.1 0.1 0.3 1.0 1.6 3.2 4.5
221
29 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Dear customer, if you need an ATEX certificate or if you cannot select the pump on the basis of the guidelines in
section 5. Pumped liquids on page 20, please fill in the following form in cooperation with a Grundfos representative.
This will help to ensure that Grundfos supplies you with a pump solution adapted to meet exactly your needs in terms
of pump type, pump materials, shaft seal type, elastomers and accessories.
Customer information
Company name: Project title:
Customer number: Reference number:
Phone number: Customer contact:
Fax number:
Email address:
Operating conditions
Pumped liquid
Type of liquid:
Chemical composition, if available:
Distilled or demineralised water? Yes: No:
Conductivity of distilled/demineralised water: [μS/cm]
Minimum liquid temperature: [°C]
Maximum liquid temperature: [°C]
Vapour pressure of liquid: [bar]
Liquid concentration: %
Liquid pH value:
Dynamic liquid viscosity: [cP] = [mPa s]
Kinematic liquid viscosity: [cSt] = [mm2/s]
Liquid density: [kg/m3]
Specific heat capacity of liquid: [kJ/(kg·K)]
Air or gas in liquid? Yes: No:
Solids in liquid? Yes: No:
Contents of solids in liquid, if available: % of mass
Additives in liquid? Yes: No:
Does the liquid crystallise? Yes: No:
When does crystallisation happen?
Does the liquid get sticky when volatiles evaporate from the pumped liquid? Yes: No:
Description of 'sticky' circumstances:
222
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
29
Pressure
Minimum inlet pressure: [bar]
Maximum inlet pressure: [bar]
Outlet pressure, inlet pressure and head: [bar]
ATEX marking
Description/sketch
Detailed description of ATEX application
Attach a drawing, if possible:
Frequency converter
Frequency converter option wanted? Yes: No:
Control parameter: Pressure: Temperature: Flow rate: Other:
Detailed description of requirements
Attach a drawing, if possible:
System information
Please provide us with information about your system
and a simple sketch if possible. This gives us an idea
as to whether you need accessories or monitoring
equipment, or whether you already have a suitable
system which makes it unnecessary to attach any
further equipment.
223
30 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
http://product-selection.grundfos.com
224
225