Grundfosliterature-836 - (PG 10,24-25)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 226

GRUNDFOS DATA BOOKLET

TP, TPD, TPE, TPE2, TPE2 D, TPE3,


TPE3 D
In-line circulator pumps
60 Hz
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

1. Pump data 4
Table of contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2. Performance range 7
Performance range, TPE2, TPE3, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Performance range, TPE2 D, TPE3 D, twin-head operation, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Performance range, 2-pole, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Performance range, 2-pole, PN 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Performance range, 4-pole, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Performance range, 4-pole, PN 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3. Product range 12
Product range, 2-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Product range, 4-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

4. Operating conditions 18
System and test pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Sound pressure level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Ambient temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Installation altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

5. Pumped liquids 20
Liquid temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
List of pumped liquids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Recommended shaft seal for water-glycol mixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

6. TP Series 200 pumps 24

7. TP Series 300 pumps 26

8. TPE Series 1000 pumps 29

9. TPE2 32

10. TPE3 36

11. Overview of functions 41

12. User interfaces for TPE pumps 46


Grundfos GO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Description of selected functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Priority of settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

13. Factory settings of E-pumps 94

14. Communication 95
Communication with TPE2, TPE2 D, TPE3, TPE3 D and TPE pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

15. Speed regulation of TPE, TPE2, TPE2 D, TPE3, TPE3 D pumps 96


Affinity equations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96

16. Control of pumps in parallel 97

17. Grundfos CUE 99


TP pumps connected to Grundfos CUE, external frequency converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99

18. Motor data 100


Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Electrical data, mains-operated motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Electrical data, speed-controlled motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104

19. Installation 105


Mechanical installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

2
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

20. MGE motors 111

Table of contents
Motors for TPE2, TPE2 D, TPE3, TPE3 D pumps and 2.2 - 11 kW 2-pole motors and 1.5 - 7.5 kW 4-pole motors fitted
on TPE Series 1000 pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
MGE motors, 11 to 18.5 kW, 4-pole, and 15 to 22 kW, 2-pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Identification of functional module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120

21. Electromagnetic compatibility, EMC 121


Electromagnetic compatibility and proper installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

22. Flanges for TP pumps 123


Flange dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

23. Curve charts 124


How to read the curve charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Curve conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125

24. Performance curves and technical data 126


TPE2, TPE2 D, TPE3, TPE3 D, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
TP, TPD, TPE, 2-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
TP, TPD, TPE, 4-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156

25. Weights and shipping volume 192


TPE2, TPE2 D, TPE3, TPE3 D, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
TP, TPD, TPE, 2-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
TP, TPD, TPE, 4-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194

26. Minimum efficiency index 197


TPE2, TPE2 D, TPE3, TPE3 D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
TP, TPD, TPE, 2-pole, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
TP, TPD, TPE, 4-pole, PN 6, 10, 16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
TP, PN 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200

27. Accessories 201


Base plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Blanking flanges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
Insulating kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
MP 204, advanced motor protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Control MP 204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Potentiometer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Grundfos GO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
CIU communication interface units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
CIM communication interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
EMC filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217

28. Minimum inlet pressure - NPSH 218


TPE2, TPE2 D, TPE3, TPE3 D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
TP, TPE, TPD 2-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
TP, TPE, TPD 4-pole, PN 6, 10, 16, 25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221

29. Key application data 222


Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222

30. Grundfos Product Center 224

3
1 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

1. Pump data
Pump data

Introduction TPE, TPE2 and TPE3 speed-controlled


TP pumps are designed for applications such as:
pumps
• district heating systems We offer the following speed-controlled pumps which
are based on the construction and choice of material of
• heating systems
the TP pumps:
• air-conditioning systems
• TPE Series 1000 pumps without factory-fitted
• district cooling systems differential-pressure sensor.
• water supply • TPE2 pumps without built-in differential-pressure
• industrial processes and temperature sensor.
• industrial cooling. • TPE3 pumps with built-in differential-pressure
The pumps are available with either mains-operated sensor and temperature sensor.
motors (TP and TPD) or electronically All pumps with 2-pole motors up to 11 kW and 4-pole
speed-controlled motors (TPE, TPE2, TPE2 D, TPE3, motors up to 7.5 kW are fitted with Grundfos
TPE3 D). permanent-magnet MGE motors that have motor
The pumps are all single-stage, in-line centrifugal efficiency class IE5 according to IEC 60034-30-2.
pumps with mechanical shaft seal. The pumps are of
TPE Series 1000 pumps
the close-coupled type, that is the pump and the motor
are separate units. The motors have a built-in frequency converter.
Via an external signal from a sensor or a controller, the
TP pumps - mains-operated pumps pumps allow for any configuration and control method
The TP range is divided into two groups based on their required, that is constant pressure, temperature or
construction: TP Series 200 and 300 pumps. flow.
For further information, see page 29.
TP Series 200 with flange connection
TPE2 pumps
DN 32 to DN 100 and motor sizes from 0.12 to 3 kW.
For further information, see page 24. The permanent magnet motors have built-in frequency
converter and the hydraulic components have been
TP Series 300 with flange connection specially designed for optimum efficiency.
We offer two versions: Via an external signal from a sensor or a controller, the
• 16-bar version with DN 32 to DN 350 flanges and pumps allow for any configuration and control method
motor sizes from 0.55 to 250 kW required, that is constant pressure, temperature, flow
• 25-bar version with DN 100 to DN 350 flanges and or level. For further information, see page 32.
motor sizes from 7.5 to 250 kW.
For further information, see page 26.

4
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
1
TPE3 pumps Why select a TPE pump?

Pump data
A pump with electronic speed control offers these
obvious benefits:
• energy savings
• increased comfort
• control and monitoring of the pump performance
• communication with the pump.
ATEX-approved TP pumps

TM06 0883 1114


On request, Grundfos offers TP and TPD pumps with
ATEX-approval.
See section 29. Key application data.
Fig. 1 Example of status display for TPE3 pumps High-efficiency motors, IE3
The pumps have a built-in differential-pressure sensor TP pumps are fitted with high-efficiency motors.
and temperature sensor. The pumps are primarily fitted with motors that meet
The pumps are factory-set to AUTOADAPT control. the legislative requirements of the EuP IE3 or IE2
grade depending on voltage and motor size.
The permanent magnet motors of the pumps have a
built-in frequency converter for continuous adjustment For further information, see Motor on pages 100 to
of the pressure to the flow rate. The hydraulic 104.
components have been specially designed for optimum Energy-optimised pumps
efficiency. TP pumps are energy-optimised and comply with the
The range is recognised as a preset solution for quick EuP Directive (Commission Regulation (EC) No.
and safe installation. The pumps have a colour display 547/2012) in which most pumps are classified or
for easy and intuitive pump setup and with full access graduated in a minimum efficiency index, MEI. See
to all functions. The pumps incorporate the following also page 197.
advanced functions:
• AUTOADAPT
• FLOWADAPT
• automatic night setback
• FLOWLIMIT
• heat energy monitor
• flow rate estimation
• proportional pressure
• constant pressure
• constant differential temperature control
• constant temperature control.
For further information, see page 32.

5
1 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Identification
Pump data

Type key for TP, TPD, TPE

Code Example TP E D 65 -120 /2 -A -F -A -BQBE


Pump range
Electronically speed-controlled pump, Series 1000
Twin-head pump
Nominal diameter of inlet and outlet ports, DN
Maximum head [dm]
Pole number
Code for pump version. The codes may be combined:
A Basic version
A3 PN 25 flange
B Oversize motor
E With ATEX approval, certificate or test report, the second character of the code for pump version is an E
I PN 6 flange
X Special version
Code for pipe connection:
F DIN flange
O Union
Code for materials:
A Basic version
Z Bronze pump housing and motor stool
B Bronze impeller
S Stainless steel 1.4408 impeller
O Ductile cast-iron pump housing with cast-iron impeller
Y Ductile cast-iron pump housing with bronze impeller
Q Ductile cast-iron pump housing with stainless steel 1.4408 impeller
Code for shaft seal including other plastic and rubber pump parts, except the neck ring

Type key for TPE2, TPE3

Code Example TPE3 D 65 -120 -S -A -F -A -BQBE

Pump range, electronically speed-controlled pump


TPE2 Without built-in sensor
TPE3 Built-in differential-pressure and temperature sensor
Twin-head pump
Nominal diameter of inlet and outlet ports, DN
Maximum head [dm]
S Built-in differential-pressure and temperature sensor
N Without built-in sensor
Code for pump version:
A Basic version
I PN 6 flange
X Special version
Code for pipe connection:
F DIN flange

Code for materials:


A Basic version
I Stainless steel 1.4308 pump housing and motor stool
Code for shaft seal including other plastic and rubber pump parts, except the neck ring

Codes for shaft seal

Code Example B Q B E

Grundfos type designation


A O-ring seal with fixed seal driver
B Rubber bellows seal
D O-ring seal, balanced
G Bellows seal with reduced seal faces
R O-ring seal with reduced seal faces

Material of rotating face


A Carbon, antimony-impregnated
B Carbon, resin-impregnated
Q Silicon carbide

Material of stationary seal


B Carbon, resin-impregnated
Q Silicon carbide
U Tungsten carbide

Material of secondary seal


E EPDM
P NBR rubber
V FKM
F FXM

6
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
2

2. Performance range

Performance range
Performance range, TPE2, TPE3, PN 6, 10, 16
See page 126 for performance curves.

+
>P@


73( '


73( '

 


 
 




 
  








 



 









TM05 8177 4914






          
4>PñK@

Performance range, TPE2 D, TPE3 D, twin-head operation, PN 6, 10, 16


See page 126 for performance curves.

+
>P@


73('
 
73('

  



     








  
 

 






    


   





 


TM05 8198 4914


 



          
4>PñK@

7
Performance range
2

8
S +
>N3D@ >P@ 73 ' 73(
31SROH+]

  


 
 
 
  
 

 
 
   
   

    
 
 
See page 138 for performance curves.

  
    

 
  
 
  
      


  
  

 



The hatched area shows the performance range of TPE pumps.


   
 

 

Performance range, 2-pole, PN 6, 10, 16

   



 


  

 
  

 
 
 


Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 125.
  

 
                 
4>PñK@
              4>OV@
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

TM02 5101 4614


p H
[kPa] [m] TP
PN 25, 2-pole, 60 Hz

160
100-1510

140
100-1360
See page 154 for performance curves.

120 100-1200

100-1040
1000
100
Performance range, 2-pole, PN 25

900 100-940
90
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

800
80
100-760

700
70

600
60

500
50
20 30 40 50 60 70 80 100 150 200 300 400 500
Q [m³/h]
6 7 8 9 10 20 30 40 50 60 70 80 90 100 Q [l/s]

TM06 6534 4717

9
Performance range
2
Performance range
2

10
p H
[kPa] [m]
100 TP(D), TPE
900 150-960
800 80
PN 6-16, 4-pole, 60 Hz
150-810
700
150-700
300
600 20 -7 5
60 0
150-610 0-
77
20 0 30
0- 0-6
500 50 80-510 6 80 40
20 30
125-480 0- 0-
80-460 15 60
0
63
35

12 20 30 0
0-

0-4
400 40 5-4 80 0- 0-
68

100-470 54 55
0

80-410 20 0
0
35

20 20
0-

0- 0-
10 150-440 49
0
54

50
0 0
0

10 -390 20
0 1 20 0
See page 156 for performance curves.

30
300 30 50-340 -35 50-4 -4
35

65- 0-4
330 0 12 0 4 0
100 0 1 30 2
0-4

5- 00
80-340
30

-34
40

0 36 1 5 50 - -3
0
50

50-270 65-310 100


12
5-3 5 0 - 34
0 20 90
20
0-4 -370

-290 12 40 15 360 0- 0-
0- 36
50-240 5-
2 30 2 0 0 40
80-280 80 1 0 0- 30 0
200 40-230 100-260 5 32
20 65-230 8 0 125 0-2
0
0-
36
32-190 -23
0
-23
0
40 20
0- 0
100-240 28 350-400
50-180 15 0

15
10 0 -
20 3

0
65-190 100 0-2 21 0- 00
-17 00 0 25 -2
15 40-180 80-170 0 125- -22
0
0 70

The hatched area shows the performance range of TPE pumps.


50-130 200 150-180
100-
65-150 150 150-160
32-140 40-150
20

10 12
40-110 80-150 0-1 5-1 15
0-2

30 60 0-
150-130 2
Performance range, 4-pole, PN 6, 10, 16

10

12 20 00
100 10 65-130 5-
13 0-
32-120 50-115 80-110 12
5 19
90 5-
13 0 300-230
0
20

80
0-

8 125-110
14

100-100
0

70 50-100
65-80
60 6 200-110
40-80 80-80 100-80
50 5 125-80

32-80 50-80
40 4
200-80

Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 125.
30 3
32-40 50-40 65-40 80-40 100-40
40-40
20 2
4 6 8 10 15 20 30 40 60 80 100 150 200 300 400 600 1000 1500 2000 3000
Q [m³/h]
2 3 4 5 6 7 8 910
10 20 30 40 50 60 80 100 200 300 400 500 Q [l/s]

TM02 8931 4717


TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
225
p H
[kPa] [m] TP
PN 25, 4-pole, 60 Hz
1000 100
900 90 150-960
800 80
150-810
700 70
150-700
600 20 300
60 0-7
70
-75
0
See page 168 for performance curves.

150-610 20
0-6 30
100-560 12 80 0-
500 50 5- 20 64
58 0-6 0
12 0 00 30
5-5 20 0-
100-470 63
50 0-5 0
35

12 40
0-

400 20 30
40 5-4 15 0-
68

0- 0-4
0

80 20 55
Performance range, 4-pole, PN 25

48 90 0
100-390 12 150- 0
0-
50
35

5- 20 0
0-

42
0 440 2 0-
54

15 200-430 00 44
0

100-340 0 -4 0
15 -400 00
300 0
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

30

30 12 -36 20
0
35

5- 0-
0-4

100-290 36 39
5 0
40
0-4

30

12
50

0-

5-3 20
0
37

40 150- -
0

36
12 340 0
100-240
15
5- 0- 20
28 0-3
0
30
20
0

200 300-360
20 20
15 0-
0- 28
24 0
100-200 15 0
0-
2 30 350-400
125-220 10 0-
15 200-250 27
0

150-180
300-230

100 10
20 30 40 50 60 80 100 150 200 300 400 500 600 800 1000 1500 2000 3000
Q [m³/h]
6 7 8 9 10 20 30 40 50 60 70 80 100 200 300 400 500 Q [l/s]

TM02 7003 4717

11
Performance range
2
3 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

3. Product range
Product range

Product range, TPE2, TPE2 D, TPE3, TPE3 D


Electronically
Design Shaft seal Pressure stage Materials speed-controlled
motor

Pump
Impeller Voltage [V]
housing

1 x 200-240 V

3 x 380-500 V
Pump type

Stainless steel 1)
TPE2, TPE2 D

TPE3, TPE3 D

EN-GJL-250

Composite
PES-GF30
Cast iron
PN 6/10
BQQE
BQBE

BAQE

DBUE

PN 10

PN 16
P2 P2

PN 6
[kW] [kW]
TPE2, TPE2 D, TPE3 TPE3 D 32-80 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D 32-120 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D 32-150 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 32-180 ● ● ● ● ● ● ● ● ● 0.55 0.55
TPE2, TPE2 D, TPE3 TPE3 D 32-200 ● ● ● ● ● ● ● ● ● 0.75 0.75
TPE2, TPE2 D, TPE3 TPE3 D 40-80 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D 40-120 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 40-150 ● ● ● ● ● ● ● ● ● 0.55 0.55
TPE2, TPE2 D, TPE3 TPE3 D 40-180 ● ● ● ● ● ● ● ● ● 0.75 0.75
TPE2, TPE2 D, TPE3 TPE3 D 40-200 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3 TPE3 D 40-240 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3 TPE3 D 50-60 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 50-80 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 50-120 ● ● ● ● ● ● ● ● ● 0.55 0.55
TPE2, TPE2 D, TPE3 TPE3 D 50-150 ● ● ● ● ● ● ● ● ● 0.75 0.75
TPE2, TPE2 D, TPE3 TPE3 D 50-180 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3 TPE3 D 50-200 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3 TPE3 D 50-240 ● ● ● ● ● ● ● ● ● 2.2
TPE2, TPE2 D, TPE3 TPE3 D 65-60 ● ● ● ● ● ● ● ● ● 0.37 0.37
TPE2, TPE2 D, TPE3 TPE3 D 65-80 ● ● ● ● ● ● ● ● ● 0.55 0.55
TPE2, TPE2 D, TPE3 TPE3 D 65-120 ● ● ● ● ● ● ● ● ● 0.75 0.75
TPE2, TPE2 D, TPE3 TPE3 D 65-150 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3 TPE3 D 65-180 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3 TPE3 D 65-200 ● ● ● ● ● ● ● ● ● 2.2
TPE2, TPE2 D, TPE3 TPE3 D 80-40 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D 80-120 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3 TPE3 D 80-150 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3 TPE3 D 80-180 ● ● ● ● ● ● ● ● ● 2.2
TPE2, TPE2 D, TPE3 TPE3 D 100-40 ● ● ● ● ● ● ● ● ● 0.25 0.25
TPE2, TPE2 D, TPE3 TPE3 D100-120 ● ● ● ● ● ● ● ● ● 1.1 1.1
TPE2, TPE2 D, TPE3, TPE3 D 100-150 ● ● ● ● ● ● ● ● ● 1.5 1.5
TPE2, TPE2 D, TPE3, TPE3 D 100-180 ● ● ● ● ● ● ● ● ● 2.2
1) Stainless-steel versions are only available as single-head pumps and with a combined PN 6/10/16 flange.

12
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
3
Product range, 2-pole, PN 6, 10, 16, 25

Product range
Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor

Pump housing Impeller Voltage [V] Voltage [V]

PN 6, 10 combination flange

3 x 660-690 YV 2)
3 x 220-255 ∆V/

3 x 220-277 ∆V/

3 x 380-480 ∆V/
3 x 380-480 ∆V
3 x 380-440 YV

3 x 380-480 YV

3 x 380-480 V

3 x 380-500 V
Pump type
TPE Series 1000 1)

Nodular cast iron

Nodular cast iron


EN-GJS-400-18

EN-GJS-400-15
Stainless steel
TP Series 200

TP Series 300

EN-GJL-250
Cast iron

Cast iron
Bronze

Bronze
BQQE

DQQE
P2 P2 P2 P2 P2 P2
BQBE
BAQE

DBUE

DAQF

PN 10
PN 16
PN 25
[kW] [kW] [kW] [kW] [kW] [kW]

TP 32-80/2 ● ● ● ● ● ● ● 0.37
TP 32-160/2 ● ● ● ● ● ● ● 0.55
TP 32-220/2 ● ● ● ● ● ● ● 0.75
TP 32-260/2 ● ● ● ● ● ● ● 1.1
TP 32-330/2 ● ● ● ● ● ● ● 1.5
TP, TPD 32-300/2 ● ● ● ● ● ● ● ● 2.2 2.2 2.2
TP, TPD 32-360/2 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 32-450/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 32-550/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 32-680/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 32-820/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP 40-80/2 ● ● ● ● ● ● ● 0.55
TP 40-160/2 ● ● ● ● ● ● ● 0.75
TP 40-240/2 ● ● ● ● ● ● ● 1.1
TP 40-270/2 ● ● ● ● ● ● ● 1.5
TP 40-330/2 ● ● ● ● ● ● ● 2.2
TP 40-390/2 ● ● ● ● ● ● ● 3.0
TP, TPD 40-400/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 40-460/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 40-530/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 40-690/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 40-820/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 40-920/2 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP 50-80/2 ● ● ● ● ● ● ● 0.55
TP 50-160/2 ● ● ● ● ● ● ● 1.1
TP 50-240/2 ● ● ● ● ● ● ● 1.5
TP, TPD 50-250/2 ● ● ● ● ● ● ● 2.2 2.2
TP, TPD 50-300/2 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 50-350/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 50-410/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 50-430/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 50-530/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 50-640/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 50-720/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 50-790/2 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 50-880/2 ● ● ● ● ● ● ● ● 22.0 22.0 22.0
TP, TPD 50-1050/2 ● ● ● ● ● ● ● 30.0 30.0
TP 65-80/2 ● ● ● ● ● ● ● 1.1
TP 65-160/2 ● ● ● ● ● ● ● 1.5
TP 65-240/2 ● ● ● ● ● ● ● 2.2
TP, TPD 65-200/2 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 65-250/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 65-340/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 65-390/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 65-480/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 65-540/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 65-630/2 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 65-740/2 ● ● ● ● ● ● ● ● 22.0 22.0 22.0
TP, TPD 65-910/2 ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 65-920/2 ● ● ● ● ● ● ● 37.0 37.0
TP, TPD 65-1050/2 ● ● ● ● ● ● ● 37.0 37.0
TP 80-160/2 ● ● ● ● ● ● ● 3.0
TP, TPD 80-200/2 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 80-240/2 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 80-290/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 80-330/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0

13
3 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Product range

Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor

Pump housing Impeller Voltage [V] Voltage [V]

PN 6, 10 combination flange

3 x 660-690 YV 2)
3 x 220-255 ∆V/

3 x 220-277 ∆V/

3 x 380-480 ∆V/
3 x 380-480 ∆V
3 x 380-440 YV

3 x 380-480 YV

3 x 380-480 V

3 x 380-500 V
Pump type
TPE Series 1000 1)

Nodular cast iron

Nodular cast iron


EN-GJS-400-18

EN-GJS-400-15
Stainless steel
TP Series 200

TP Series 300

EN-GJL-250
Cast iron

Cast iron
Bronze

Bronze
BQQE

DQQE
P2 P2 P2 P2 P2 P2
BQBE
BAQE

DBUE

DAQF

PN 10
PN 16
PN 25
[kW] [kW] [kW] [kW] [kW] [kW]

TP, TPD 80-400/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0


TP, TPD 80-480/2 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 80-530/2 ● ● ● ● ● ● ● ● 22.0 22.0 22.0
TP, TPD 80-640/2 ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 80-750/2 ● ● ● ● ● ● ● 37.0 37.0
TP, TPD 100-230/2 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 100-300/2 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 100-370/2 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 100-350/2 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 100-380/2 ● ● ● ● ● ● ● ● 22.0 22.0 22.0
TP, TPD 100-530/2 ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 100-630/2 ● ● ● ● ● ● ● 37.0 37.0
TP, TPD 100-700/2 ● ● ● ● ● ● ● 45.0 45.0
TP 100-760/2 ● ● ● ● ● ● ● 75.0
TP 100-940/2 ● ● ● ● ● ● ● 90.0
TP 100-1040/2 ● ● ● ● ● ● ● 110.0
TP 100-1200/2 ● ● ● ● ● ● ● 132.0
TP 100-1360/2 ● ● ● ● ● ● ● 160.0
TP 100-1510/2 ● ● ● ● ● ● ● 200.0

● Standard
1) TPE pumps are not available in twin-head versions.
2)
2-pole motors above 7.5 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot be operated at 3 X 660-690 YV.

14
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
3
Product range, 4-pole, PN 6, 10, 16, 25

Product range
Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor

Pump

PN 6, 10 combination flange
Impeller Voltage [V] Voltage [V]
housing

3 x 660-690 YV 2)
3 x 380-480 ∆V/
3 x 220-255 ΔV/

3 x 220-277 ΔV/

3 x 380-480 ΔV
3 x 380-440 YV

3 x 380-480 YV
Pump type

3 x 380-480 V

3 x 380-500 V
EN-GJS-400-18-LT
TPE Series 1000 1)

Nodular cast iron

Nodular cast iron


EN-GJS-400-15
Stainless steel
TP Series 200

TP Series 300

EN-GJL-250
Cast iron

Cast iron
Bronze

Bronze
BQQE

DQQE
BQBE
BAQE

DAQF
DBUE

PN 10
PN 16
PN 25
P2 P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW] [kW]
TP 32-40/4 ● ● ● ● ● ● ● 0.12
TP 32-80/4 ● ● ● ● ● ● ● 0.25
TP, TPD 32-120/4 ● ● ● ● ● ● ● 0.55
TP, TPD 32-140/4 ● ● ● ● ● ● ● 0.75
TP, TPD 32-190/4 ● ● ● ● ● ● ● 1.1
TP 40-40/4 ● ● ● ● ● ● ● 0.25
TP 40-80/4 ● ● ● ● ● ● ● 0.55
TP, TPD 40-110/4 ● ● ● ● ● ● ● 0.75
TP, TPD 40-150/4 ● ● ● ● ● ● ● 1.1
TP, TPD 40-180/4 ● ● ● ● ● ● ● 1.5
TP, TPD 40-230/4 ● ● ● ● ● ● ● 2.2 2.2
TP 50-40/4 ● ● ● ● ● ● ● 0.25
TP 50-80/4 ● ● ● ● ● ● ● 0.55
TP, TPD 50-100/4 ● ● ● ● ● ● ● 0.75
TP, TPD 50-115/4 ● ● ● ● ● ● ● 1.1
TP, TPD 50-130/4 ● ● ● ● ● ● ● 1.5
TP, TPD 50-180/4 ● ● ● ● ● ● ● 2.2
TP, TPD 50-240/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 50-270/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 50-340/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP 65-40/4 ● ● ● ● ● ● ● 0.37
TP 65-80/4 ● ● ● ● ● ● ● 1.1
TP, TPD 65-130/4 ● ● ● ● ● ● ● 1.5
TP, TPD 65-150/4 ● ● ● ● ● ● ● 2.2 2.2
TP, TPD 65-190/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 65-230/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 65-310/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 65-330/4 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP 80-40/4 ● ● ● ● ● ● ● 0.75
TP 80-80/4 ● ● ● ● ● ● ● 1.5
TP, TPD 80-110/4 ● ● ● ● ● ● ● 2.2 2.2
TP, TPD 80-150/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 80-170/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 80-230/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 80-280/4 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 80-340/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 80-410/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 80-460/4 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 80-510/4 ● ● ● ● ● ● ● 22.0 22.0
TP 100-40/4 ● ● ● ● ● ● ● 1.1
TP 100-80/4 ● ● ● ● ● ● ● 2.2
TP, TPD 100-100/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP, TPD 100-130/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP, TPD 100-150/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 100-170/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 100-200/4* ● ● ● ● ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 100-240/4* ● ● ● ● ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 100-260/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 100-290/4* ● ● ● ● ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 100-340/4* ● ● ● ● ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 100-350/4 ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 100-390/4* ● ● ● ● ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 100-470/4* ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP 100-560/4 ● ● ● ● ● ● ● 37.0

15
3 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Product range

Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor

Pump

PN 6, 10 combination flange
Impeller Voltage [V] Voltage [V]
housing

3 x 660-690 YV 2)
3 x 380-480 ∆V/
3 x 220-255 ΔV/

3 x 220-277 ΔV/

3 x 380-480 ΔV
3 x 380-440 YV

3 x 380-480 YV
Pump type

3 x 380-480 V

3 x 380-500 V
EN-GJS-400-18-LT
TPE Series 1000 1)

Nodular cast iron

Nodular cast iron


EN-GJS-400-15
Stainless steel
TP Series 200

TP Series 300

EN-GJL-250
Cast iron

Cast iron
Bronze

Bronze
BQQE

DQQE
BQBE
BAQE

DAQF
DBUE

PN 10
PN 16
PN 25
P2 P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW] [kW]
TP 125-80/4 ● ● ● ● ● ● ● ● 3.0 3.0 3.0
TP 125-110/4 ● ● ● ● ● ● ● ● 4.0 4.0 4.0
TP 125-135/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 125-130/4 ● ● ● ● ● ● ● ● 5.5 5.5 5.5
TP, TPD 125-160/4 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP, TPD 125-200/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP, TPD 125-230/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP 125-220/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 125-280/4 ● ● ● ● ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 125-340/4 ● ● ● ● ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 125-365/4 ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 125-420/4 ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 125-480/4 ● ● ● ● ● ● ● ● ● ● ● 37.0 37.0
TP 125-550/4 ● ● ● ● ● ● ● 45.0
TP 125-580/4 ● ● ● ● ● ● ● 55.0
TP 150-130/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP 150-160/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP 150-200/4 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP 150-220/4 ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 150-180/4 ● ● ● ● ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP, TPD 150-210/4 ● ● ● ● ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP, TPD 150-240/4 ● ● ● ● ● ● ● ● ● ● ● 22.0 22.0
TP, TPD 150-300/4 ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP, TPD 150-340/4 ● ● ● ● ● ● ● ● ● ● ● 37.0 37.0
TP 150-360/4 ● ● ● ● ● ● ● ● ● ● ● 30.0
TP 150-400/4 ● ● ● ● ● ● ● ● ● ● ● 37.0
TP 150-440/4 ● ● ● ● ● ● ● ● ● ● ● 45.0
TP 150-480/4 ● ● ● ● ● ● ● ● ● ● ● 55.0
TP 150-610/4 ● ● ● ● ● ● ● ● ● ● ● 75.0
TP 150-700/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 150-810/4 ● ● ● ● ● ● ● ● ● ● ● 110.0
TP 150-960/4 ● ● ● ● ● ● ● ● ● ● ● 132.0
TP 200-80/4 ● ● ● ● ● ● ● ● 7.5 7.5 7.5
TP 200-110/4 ● ● ● ● ● ● ● ● 11.0 11.0 11.0
TP 200-140/4 ● ● ● ● ● ● ● ● 15.0 15.0 15.0
TP 200-190/4 ● ● ● ● ● ● ● ● 18.5 18.5 18.5
TP 200-210/4 ● ● ● ● ● ● ● 22.0 22.0
TP 200-250/4 ● ● ● ● ● ● ● ● ● ● ● 30.0 30.0
TP 200-280/4 ● ● ● ● ● ● ● ● ● ● ● 37.0
TP 200-320/4 ● ● ● ● ● ● ● ● ● ● ● 45.0
TP 200-360/4 ● ● ● ● ● ● ● ● ● ● ● 55.0
TP 200-390/4 ● ● ● ● ● ● ● ● ● ● ● 75.0
TP 200-400/4 ● ● ● ● ● ● ● ● ● ● ● 75.0
TP 200-430/4 ● ● ● ● ● ● ● ● ● ● ● 55.0
TP 200-440/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 200-490/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 200-500/4 ● ● ● ● ● ● ● ● ● ● ● 110.0
TP 200-540/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 200-600/4 ● ● ● ● ● ● ● ● ● ● ● 110.0
TP 200-680/4 ● ● ● ● ● ● ● ● ● ● ● 132.0
TP 200-770/4 ● ● ● ● ● ● ● ● ● ● ● 160.0
TP 300-230/4 ● ● ● ● ● ● ● ● ● ● ● 45.0
TP 300-270/4 ● ● ● ● ● ● ● ● ● ● ● 55.0
TP 300-360/4 ● ● ● ● ● ● ● ● ● ● ● 75.0
TP 300-370/4 ● ● ● ● ● ● ● ● ● ● ● 90.0
TP 300-440/4 ● ● ● ● ● ● ● ● ● ● ● 110.0
TP 300-550/4 ● ● ● ● ● ● ● ● ● ● ● 132.0
TP 300-630/4 ● ● ● ● ● ● ● ● ● ● ● 160.0

16
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
3

Product range
Electronically
Pressure
Design Shaft seal Materials Mains-operated motor speed-controlled
stage
motor

Pump

PN 6, 10 combination flange
Impeller Voltage [V] Voltage [V]
housing

3 x 660-690 YV 2)
3 x 380-480 ∆V/
3 x 220-255 ΔV/

3 x 220-277 ΔV/

3 x 380-480 ΔV
3 x 380-440 YV

3 x 380-480 YV
Pump type

3 x 380-480 V

3 x 380-500 V
EN-GJS-400-18-LT
TPE Series 1000 1)

Nodular cast iron

Nodular cast iron


EN-GJS-400-15
Stainless steel
TP Series 200

TP Series 300

EN-GJL-250
Cast iron

Cast iron
Bronze

Bronze
BQQE

DQQE
BQBE
BAQE

DAQF
DBUE

PN 10
PN 16
PN 25
P2 P2 P2 P2 P2 P2
[kW] [kW] [kW] [kW] [kW] [kW]
TP 300-640/4 ● ● ● ● ● ● ● ● ● ● ● 200.0
TP 300-750/4 ● ● ● ● ● ● ● ● ● ● ● 250.0
TP 350-400/4 ● ● ● ● ● ● ● ● ● ● ● 132.0
TP 350-450/4 ● ● ● ● ● ● ● ● ● ● ● 160.0
TP 350-540/4 ● ● ● ● ● ● ● ● ● ● ● 200.0
TP 350-680/4 ● ● ● ● ● ● ● ● ● ● ● 250.0

● Standard
* Only TP pumps are available in PN 25.
1) TPE pumps are not available in twin-head versions.
2)
4-pole motors above 4 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot be operated at 3 x 660-690 YV.

17
4 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

4. Operating conditions
Operating conditions

System and test pressures Ambient temperature


System pressure Test pressure MG IE3 motors:
Pressure 0.75 - 22 kW motors, 2-pole -30 to +60 °C
[bar] [MPa] [bar] [MPa] 0.75 - 15 kW motors, 4-pole
Siemens IE3 motors:
PN 6 6 0.6 10 1.0 30-315 kW motors, 2-pole -20 to +55 °C
PN 10 10 1.0 16 1.6 18.5 - 315 kW motors, 4-pole
PN 16 16 1.6 24 2.4 MGE motors:
2.2 - 11 kW, 2-pole -20 to +50 °C
PN 25 25 2.5 38 3.8
3 - 7.5 kW, 4-pole
MGE motors:
Sound pressure level 15-22 kW, 2-pole
11 - 18.5 kW, 4-pole
-20 to +40 °C

Storage Down to -30 °C


Maximum sound pressure level [dB(A)] - ISO 3743
Motor
Three-phase motors
[kW]
2-pole 4-pole
0.12 - -
0.25 - 45
0.37 57 45
0.55 56 45
0.75 57 50.5
1.1 58 50.5
1.5 64 51.5
2.2 65 54.5
3.0 53.5 57
4.0 67.5 56
5.5 68 55
7.5 65 56
11.0 64.5 58
15.0 65 58
18.5 65.5 65
22.0 70.5 65
30.0 75 66
37.0 75 65
45.0 75 65
55.0 75 68
75.0 77 71
90.0 77 71
110.0 81 75
132.0 81 75
160.0 81 75
200.0 81 75
250.0 86 77
315.0 - 77

The values apply only to MG and Siemens motors. The


values have a tolerance of 3 dB according to EN ISO
4871. The tolerance is not added to the values in the
table.
The audible noise from TP pumps is primarily noise
from the motor fan. The selection of TPE pumps will
reduce the noise at partial load, as the motor and,
consequently, the motor fan runs at a lower speed.
Possible flow noise from control valves is also reduced
at partial load in the case of the TPE pump.

18
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
4
Installation altitude In order to maintain the galvanic isolation and ensure

Operating conditions
correct clearance according to EN 60664-1:2007, you
Pump with standard motor must adapt the supply voltage to the altitude:
If the ambient temperature exceeds maximum values
Supply voltage [V]
or if the motor is located more than 1000 m above sea
level, the motor output, P2, must be reduced due to the 500
480

TM06 9866 3617


low density and consequent low cooling effect of the 460
air. In such cases, it may be necessary to use an 440
420
oversize motor with a higher rated output. 400
380
0 500 1000 1500 2000 2500 3000 3500 4000 Altitude [m]
Pos. Description
Siemens IE3 motors: Fig. 4 Supply voltage for three-phase motor in relation to
3 30 - 315 kW motors, 2-pole altitude
18.5 - 315 kW motors, 4-pole
MG IE3 motors:
Supply voltage [V]
2 0.75 - 22 kW motors, 2-pole
0.75 - 15 kW motors, 4-pole 250
1 Other motor sizes 240

230
P2

TM06 9867 3617


[%] 3 220
100 2 210
90
200
80 1 0 500 1000 1500 2000 2500 3000 3500 4000 Altitude [m]
70 Fig. 5 Supply voltage for single-phase motor in relation to
60 altitude
TM04 4914 2209

50
20 25 30 35 40 45 50 55 60 65 70 75 80 Note:
t [°C] Motors installed more than 1000 m above sea level
1000 2250 3500 4750 m must not be fully loaded due to the low density and
Fig. 2 Maximum motor output in relation to ambient consequent low cooling effect of the air.
temperature and altitude If the motor is to operate at ambient temperatures
between 50 and 60 °C, select an oversized motor.
Pump with Grundfos MGE motor Contact Grundfos.
Description
MGE motors:
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole

Installation altitude is the height above sea level of the


installation site.
Motors installed up to 1000 m above sea level can be
loaded 100 %.
The motors can be installed up to 3500 m above sea
level.

P2 [%]

100

90
TM05 5243 3717

80

70

60
0 500 1000 1500 2000 2500 3000 3500 Altitude [m]

Fig. 3 Motor output power in relation to altitude

19
5 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

5. Pumped liquids
Pumped liquids

The pump is suitable for thin, clean, non-aggressive Liquid temperature


and non-flammable liquids, not containing solid
particles or fibres that may attack the pump Liquid temperature: -40 to +150 °C.
mechanically or chemically. See List of pumped liquids Please note that shaft seals operating close to their
on page 21. maximum temperature will require regular
maintenance or replacement.
Examples:
• Central heating system water. The water must meet Pump type Shaft seal Temperature
the requirements of accepted standards on water BQBE 0 to +140 °C
TP Series 200
quality in heating systems. BQQE -25 to +120 °C
• cooling liquids TP Series 300, BAQE 0 to +120 °C (140 °C) 1)
16-bar version BQQE -25 to +120 °C
• domestic hot water
TP Series 300, DQQE -40 to +120 °C
• industrial liquids 25-bar version DAQF 0 to +150 °C2)
• softened water. BQBE 0 to +120 °C3)
TPE2, TPE3
If glycol or another antifreeze agent is added to the BQQE -25 to +120 °C
pumped liquid, the pump must have a shaft seal of the
1) TP Series 300, PN 16 pumps are designed for a maximum
BQQE or DQQE type See Recommended shaft seal
operating temperature of 140 °C. For operation above 120 °C, an
for water-glycol mixture on page 23. alternative shaft seal is to be selected. Contact Grundfos.
2) For operation above 140 °C, contact Grundfos. At 120 to 150 °C,
The pumping of liquids with a density and/or kinematic
the maximum operating pressure is less than 23 bar.
viscosity higher than that of water will have the 3)
140 °C for a short period.
following effects:
• a considerable pressure drop Depending on the type of cast-iron version and the
• a drop in hydraulic performance pump application, the maximum liquid temperature
may be limited by local regulations and laws.
• a rise in power consumption.
In such cases, fit the pump with a bigger motor. If in
doubt, contact Grundfos.
If the water contains mineral or synthetic oils or
chemicals or if other liquids than water are pumped,
chose the O-rings accordingly.

20
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
5
List of pumped liquids Legend

Pumped liquids
TP and TPD pumps are designed for circulation A
May contain additives or impurities that may cause shaft seal
problems.
systems with constant flow, TPE2, TPE2 D, TPE3,
The density and/or viscosity differ from those of water.
TPE3 D and TPE pumps for systems with variable flow. B
Consider this when calculating motor and pump performance.
Thanks to their design, you can use the pumps in a C The liquid must be oxygen-free (anaerobic).
wider liquid temperature range than pumps of the
D Risk of crystallisation or precipitation in shaft seal.
canned rotor type.
E Insoluble in water.
A number of typical liquids are listed below.
F The shaft seal rubber parts must be replaced with FKM rubber.
You can use other pump versions, but we consider the
ones stated in the list to be the best choices. G Bronze housing or impeller required.

The list is intended as a general guide only, and it Risk of formation of ice on the standby pump.
H
The risk only applies to TP, TPE Series 200 pumps.
cannot replace actual testing of the pumped liquids
and pump materials under specific working conditions.
If in doubt, we recommend that you fill in the form
shown on page 222 and contact Grundfos.
Use the list with some caution, as factors such as
concentration of the pumped liquid, liquid temperature
or pressure may affect the chemical resistance of a
specific pump version.

Shaft seal
Additional
Pumped liquids Notes
information TP Series 300 TP Series 300
TPE2, TPE3 TP Series 200
PN 16 PN 25

Water

BQBE BQBE
< 120 °C BQQE DQQE 4)
Groundwater BQQE BQQE
> 120 °C BQBE DAQF2) + 4) DAQF 4)
BQBE BQBE BAQE DAQF
< 120 °C
BQQE BQQE BQQE DQQE
Boiler-feed water
< 140 °C BQBE DAQF 2) DAQF
< 150 °C DAUE2)
BQBE BQBE BAQE DAQF
District heating water < 120 °C
BQQE BQQE BQQE DQQE
BQBE BQBE BAQE DAQF
< 120 °C
BQQE BQQE BQQE DQQE
Condensate
BAQE
> 120 °C BQBE DAQF
DAQF2)
BQBE BQBE BAQE
< 120 °C DAQF
Softened water C BQQE BQQE BQQE
> 120 °C BQBE DAQF2) DAQF
pH > 6.5, 40 °C, BQBE BQBE
Brackish water G BQQE DQQE
1000 ppm Cl- BQQE BQQE

Coolants

Ethylene glycol B, D, H < 120 °C BQQE BQQE BQQE DQQE


Glycerine (glycerol) B, D, H < 120 °C BQQE BQQE BQQE DQQE
Potassium acetate B, D, C, H < 120 °C BQQE BQQE BQQE DQQE
Potassium formate B, D, C, H < 120 °C BQQE BQQE BQQE DQQE
Propylene glycol B, D, H < 120 °C BQQE BQQE BQQE DQQE
Brine sodium chloride B, D, C, H < 5 °C, 30 % BQQE BQQE BQQE DQQE

Synthetic oils

BQBE BQBE BAQE DAQF


Silicone oil B, E
BQQE BQQE BQQE DQQE
(To be continued)

21
5 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Pumped liquids

Shaft seal
Additional
Pumped liquids Notes
information TP Series 300 TP Series 300
TPE2, TPE3 TP Series 200
PN 16 PN 25

Vegetable oils

BUBV 2) + 3) BUBV 2) BAQV 2)


Corn oil B, F, E DAQF
BQQV 2) + 3) BQQV 2) BQQV 2)
BUBV 2) + 3) BUBV 2) BAQV 2)
Olive oil B, F, E < 80 °C DAQF
BQQV 2) + 3) BQQV 2) BQQV 2)
BUBV 2) + 3) BUBV 2) BAQV 2)
Peanut oil B, F, E DAQF
BQQV 2) + 3) BQQV 2) BQQV 2)
BUBV 2) + 3) BUBV 2) BAQV 2)
Rapeseed oil D, B, F, E DAQF
BQQV 2) + 3) BQQV 2) BQQV 2)
BUBV 2) + 3) BUBV 2) BAQV 2)
Soybean oil B, F, E DAQF
BQQV 2) + 3) BQQV 2) BQQV 2)

Cleaning agents

BQQE BQQE BQQE


Soap (salts of fatty acids) A, E, (F) < 80 °C DQQE
(BQQV) 2) (BQQV) 2) (BQQV) 2)
BQQE BQQE BQQE
Alkaline degreasing agent A, E, (F) < 80 °C DQQE
(BQQV) 2) (BQQV) 2) (BQQV) 2)

Oxidants

BQBE BQBE DAQF


Hydrogen peroxide < 40 °C, < 2 % BQQE
BQQE BQQE DQQE

Salts

Ammonium bicarbonate A < 20 °C, < 15 % BQQE BQQE BQQE DQQE


Calcium acetate A, B < 20 °C, < 30 % BQQE BQQE BQQE DQQE
Potassium bicarbonate A < 20 °C, < 20 % BQQE BQQE BQQE DQQE
Potassium carbonate A < 20 °C, < 20 % BQQE BQQE BQQE DQQE
Potassium permanganate A < 20 °C, < 10 % BQQE BQQE BQQE DQQE
Potassium sulphate A < 20 °C, < 20 % BQQE BQQE BQQE DQQE
Sodium acetate A < 20 °C, < 100 % BQQE BQQE BQQE DQQE
Sodium bicarbonate A < 20 °C, < 2 % BQQE BQQE BQQE DQQE
Sodium carbonate A < 20 °C, < 20 % BQQE BQQE BQQE DQQE
Sodium nitrate A < 0 °C, < 40 % BQQE BQQE BQQE DQQE
Sodium nitrite A < 20 °C, < 40 % BQQE BQQE BQQE DQQE
Sodium phosphate (di) A < 100 °C, < 30 % BQQE BQQE BQQE DQQE
Sodium phosphate (tri) A < 90 °C, < 20 % BQQE BQQE BQQE DQQE
Sodium sulphate A < 20 °C, < 20 % BQQE BQQE BQQE DQQE
Sodium sulphite A < 20 °C, < 1 % BQQE BQQE BQQE DQQE

Alkalis

Ammonium hydroxide < 100 °C, < 30 % BQQE BQQE BQQE DQQE
Calcium hydroxide A < 100 °C, < 10 % BQQE BQQE BQQE DQQE
Potassium hydroxide A < 20 °C, < 20 % BQQE BQQE BQQE DQQE
Sodium hydroxide A < 40 °C, < 20 % BQQE BQQE BQQE DQQE
1)
Do not use BAQE for potable water. For potable water, we recommend that you use a BBQE shaft seal.
2) The shaft seal is not standard, but available on request.
3)
Applies only for TPE2.
4)
Do not use for potable water.

22
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
5
Recommended shaft seal for water-glycol mixture

Pumped liquids
Glycol content
[%]
50

40

30
BQQE
/DQQE

TM06 1032 2315


20

10
-25-20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120

Temperature [°C]

Fig. 6 Operating range of EPDM shaft seals

Glycol content
[%]
50

40

30 BQQV
TM06 1034 1514

20

10
-10 0 10 20 30 40 50 60 70 80 90

Temperature [°C]

Fig. 7 Operating range of FKM shaft seals

23
6 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
226

6. TP Series 200 pumps


TP Series 200 pumps

Materials
TP Series 200

5 4

GR8261
2

TM03 1211 4715


Fig. 8 TP Series 200 1

Technical data
Flow rate: Up to 90 m3/h Fig. 9 Sectional drawing of a TP Series 200 (flanged
Head: Up to 27 m model)
Liquid temperature: -25 to +140 °C
Material specification, Series 200
Max. operating pressure: Up to 16 bar
Direction of rotation: Counterclockwise Pos. Component Material EN/DIN
Cast iron EN-GJL-250, 0.6020
Construction 1 Pump housing
bronze CuSn10 2.1093

Grundfos TP Series 200 pumps are single-stage, 2 Impeller Stainless steel 1.4301

close-coupled pumps with in-line inlet and outlet ports 3 Shaft Stainless steel 1.4305

of identical diameter. 4 Coupling Cast iron EN-GJL-400 0.7040


Cast iron EN-GJL-250, 0.6025
The pumps are fitted with a fan-cooled asynchronous 5 Pump head
bronze 2.1093
motor. Motor and pump shafts are connected via a Secondary seals EPDM
rigid two-part coupling. Rotating seal
Silicon carbide
The pumps have PN 6 or PN 10 flanges. face
Carbon (resin-impregnated),
The pumps are equipped with an unbalanced Stationary seat
silicon carbide
mechanical shaft seal.
The pumps are of the top-pull-out design, that is you
can remove the power head (motor, pump head and
impeller) for maintenance or service while the pump
housing remains in the pipe.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
The pumps are equipped with high-efficiency motors.
Pumps with bronze pump housing, version B, are
suitable for circulation of domestic hot water.

24
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
227 6
Mechanical shaft seal Features and benefits

TP Series 200 pumps


Two types of unbalanced mechanical shaft seals are TP Series 200 pumps have the following product
available as standard: features and benefits:
• BQBE Optimised hydraulics for high efficiency
The BQBE shaft seal is a rubber bellows seal with
– Reduced power consumption.
silicon carbide/carbon seal faces and secondary
seals of EPDM. High-efficiency motors
• BQQE – TP pumps are fitted with high-efficiency motors.
The BQQE shaft seal is a rubber bellows seal with High-efficiency motors offer reduced energy
silicon carbide/silicon carbide seal faces and consumption. TP pumps are primarily fitted with
secondary seals of EPDM. motors that meet the legislative requirements of
Information on a selection of common pumped liquids the EuP IE3 grade. For further information, see
with recommended shaft seals is shown on page 21. Motor, pages 100 to 104.
Shaft seal specification Top-pull-out design
Unbalanced shaft Version NU according to EN
– Easy dismantling in case of service.
TP Series 200
seal 12756
In-line design
Shaft diameter 12 and 16 mm
Rubber bellows EPDM – Contrary to end-suction pumps, in-line pumps
Silicon carbide/carbon allow straight pipes and thus often reduced
Seal faces Silicon carbide/silicon installation costs.
carbide
Pump housing and pump head are electrocoated to
Special shaft seals are available for partly conditioned improve the corrosion resistance
water or other liquids containing abrasive or
– Electrocoating includes:
crystallising particles. See page 21.
1. Alkaline cleaning.
Connections 2. Pretreatment with zinc phosphate coating.
3. Cathodic electrocoating, epoxy.
TP Series 200 pumps up to DN 65 are equipped with 4. Curing of paint film at 200 to 250 °C.
combination flanges PN 6 / PN 10. DN 80 or DN 100 For low-temperature applications at a high
pumps have either PN 6 or PN 10 flanges. All flanges humidity, Grundfos offers TP pumps with extra
can be connected to flanges in accordance with EN surface treatment to avoid corrosion. These
1092-2 and ISO 7005-2. pumps are available on request.
Stainless-steel impeller and neck ring
– Wear-free operation with high efficiency.

25
7 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

7. TP Series 300 pumps


TP Series 300 pumps

Construction
Grundfos TP, TPD Series 300 pumps are single-stage,
close-coupled pumps with in-line inlet and outlet ports
of identical diameter.
The pumps are fitted with a fan-cooled asynchronous
motor. Motor and pump shafts are connected via a
rigid sleeve coupling.
Most TP Series 300 pumps are available as
single-head, TP, and twin-head, TPD pumps.

GR8259
TP Series 300 pumps have PN 16 flanges or PN 25
flanges.
Fig. 10 TP Series 300 The pumps are fitted with an unbalanced or a balanced
mechanical shaft seal.
Technical data The pumps are of the top-pull-out design, that is you
can remove the power head (motor, pump head and/or
PN 16 version PN 25 version
motor stool and impeller) for maintenance or service
3
Flow rate [m /h] Up to 2000 Up to 2000 while the pump housing remains in the pipes.
Head [m] Up to 93 Up to 150 The pump housing is provided with a replaceable wear
ring to ensure high pump efficiency for life.
Liquid temperature [°C] -25 to +140 -40 to +150*
The twin-head pumps are designed with two parallel
Maximum operating
pressure [bar]
16 25 power heads. A non-return flap valve in the common
outlet port is opened by the flow of the pumped liquid
Direction of rotation Clockwise and prevents backflow of liquid into the idle pump
* At 120 to 150 °C, the maximum operating pressure is less than 23 head.
bar. As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
The impeller is hydraulically balanced to minimise axial
forces.
TP, TPD, TPE Series 300 pumps are equipped with
high-efficiency motors.
TP Series 300 pumps with bronze impeller are suitable
for pumping brine.

26
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
7
Materials TP Series 300, PN 25

TP Series 300 pumps


Pos. Component Material EN/DIN
Ductile cast iron
1 Pump housing EN-JS 1025
EN-GJS-400-18-LT
4
Cast iron EN-GJL-200, EN-JL 1030
2 Impeller
bronze CuSn10 2.1093
Stub shaft Stainless steel 1.4301
3
3 Two-part stub shaft Stainless steel/steel 1.4301/1.0301
4 Motor stool Cast iron EN-GJL-250 EN-JL 1040
5 EPDM
2 Secondary seals
FXM
Metal-impregnated
1 Rotating seal face carbon
Silicon carbide

TM04 9586 2115


Stationary seat Silicon carbide
Bronze CuSn10/brass
5 Wear ring 2.1093
CuZn34Mn3Al2Fe1-C

Mechanical shaft seal


Fig. 11 Sectional drawing of TP Series 300
For 16-bar versions, these types of unbalanced
Material specification mechanical shaft seals are available as standard:
TP Series 300, PN 16 • BAQE
The BAQE shaft seal is a rubber bellows seal with
Pos. Component Material EN/DIN carbon/silicon carbide seal faces and secondary
1 Pump housing Cast iron EN-GJL-250 EN-JL 1040 seals of EPDM.
2 Impeller
Cast iron EN-GJL-200, EN-JL 1030 • BQQE
bronze CuSn10 2.1093 The BQQE shaft seal is a rubber bellows seal with
Stub shaft Stainless steel 1.4301 silicon carbide/silicon carbide seal faces and
3
Two-part stub shaft Stainless steel/steel 1.4301/1.0301
secondary seals of EPDM.
Pump head/motor
4 Cast iron EN-GJL-250 EN-JL 1040
stool For 25-bar versions, these types of balanced
Secondary seals EPDM mechanical shaft seals are available as standard:
Rotating seal face
Metal-impregnated • DAQF
carbon, silicon carbide
The DAQF shaft seal is a balanced O-ring seal with
Stationary seat Silicon carbide
carbon/silicon carbide seal faces and secondary
Bronze CuSn10/brass
5 Wear ring
CuZn34Mn3Al2Fe1-C
2.1093 seals of FXM.
• DQQE
The DQQE shaft seal is a balanced O-ring seal with
silicon carbide/silicon carbide seal faces and
secondary seals of EPDM.
For further information about common pumped liquids
with recommended shaft seals, see page 21.
Special shaft seals are available for partly conditioned
water or other liquids containing abrasive or
crystallising particles. See page 21.

Connections
TP Series 300 pumps have PN 16 or PN 25 flanges. All
dimensions are according to ISO 7005-2 or EN 1092-2.

27
7 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Features and benefits


TP Series 300 pumps

TP Series 300 pumps have these features and


benefits:
Optimised hydraulics for high efficiency
– Reduced power consumption.
High-efficiency motors
– TP pumps are fitted with high-efficiency motors.
High-efficiency motors offer reduced energy
consumption. TP pumps are primarily fitted with
motors that meet the legislative requirements of
the EuP IE3 or IE2 grade depending on voltage
and motor size. For further information, see Motor
on pages 100 to 104.
Top-pull-out design
– Easy dismantling in case of service.
In-line design
– Contrary to end-suction pumps, in-line pumps
allow straight pipes and thus often reduced
installation costs.
Motor-pump shaft with sleeve coupling
– Stable and quiet operation.
– Easy dismantling in case of service.
Hydraulically and mechanically balanced impeller
– The impeller is hydraulically and mechanically
balanced to increase the life of motor bearings
and shaft seal.
Pump housing and pump head or motor stool are
electrocoated to improve the corrosion resistance
Electrocoating includes:
1. Alkaline cleaning.
2. Pretreatment with zinc phosphate coating.
3. Cathodic electrocoating, epoxy.
4. Curing of paint film at 200-250 °C.
For low-temperature applications at a high humidity,
Grundfos offers TP pumps with extra surface treatment
to avoid corrosion. These pumps are available on
request.

28
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
8

8. TPE Series 1000 pumps

TPE Series 1000 pumps


Applications
TPE Series 1000 pumps have integrated speed control
for automatic adaptation of performance to current

TM06 7383 3416 - TM06 7385 3416


conditions.
The energy consumption is thus kept at a minimum.
The pumps can operate at any duty point within the
range between 25 % and 100 % speed.

HH
[m]
[m]

100 %
Fig. 12 TPE Series 1000

Technical data
Flow rate: Up to 340 m3/h
Head: Up to 90 m
Liquid temperature: -25 to +140 °C

TM01 4916 1099


25 %
Maximum operating pressure: 16 bar
Motor sizes, three-phase: 2.2 to 22 kW
0
Q [m3h]
Construction 0 Q [m³/h]
TPE Series 1000 pumps are based on TP Series 300 Fig. 13 Duty range of TPE Series 1000 pumps
pumps.
The 100 % curve corresponds to the curve of a pump
The main difference between the TP and the TPE with a mains-operated motor.
Series 1000 pump range is the motor. The MGE motor
Depending on the application, the pumps offer energy
of TPE Series 1000 pumps has a built-in frequency
savings, increased comfort or improved processing.
converter for continuous adjustment of the pressure to
the flow rate. All pumps with 2-pole motors up to 11 kW The pumps can be fitted with sensor types meeting the
and 4-pole motors up to 7.5 kW are fitted with requirements mentioned in section Accessories on
Grundfos permanent-magnet MGE motors that have page 201.
motor efficiency class IE5 according to IEC
60034-30-2.
The pumps are suitable for applications where the
pressure, temperature, flow rate or another parameter
is to be controlled on the basis of signals from a sensor
at some point in the system.
Note: The pumps are not fitted with a sensor from
factory.
For further information on construction and materials
of the pumps, see pages 26 to 28.

29
8 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

The charts below show possible control modes of the pumps in different applications.
TPE Series 1000 pumps

System application Select this control mode Pump type


In systems with relatively large pressure losses in the distribution pipes and in
air-conditioning and cooling systems. Constant differential pressure with
• Two-pipe heating systems with thermostatic valves and the following: differential-pressure sensor located
– very long distribution pipes in the system
– strongly throttled pipe balancing valves
– differential-pressure regulators
H
– large pressure losses in those parts of the system through which the total
quantity of water flows, for example boiler, heat exchanger and distribution All
pipe up to the first branching.
• Primary circuit pumps in systems with large pressure losses in the primary
circuit.
• Air-conditioning systems with the following:
– heat exchangers (fan coils)
– cooling ceilings Q
– cooling surfaces.

In systems with relatively small pressure losses in the distribution pipes. Constant differential pressure
• Two-pipe heating systems with thermostatic valves and the following:
– sized for natural circulation
H
– small pressure losses in those parts of the system through which the total
quantity of water flows, for example boiler, heat exchanger and distribution
pipe up to the first branching, or modified to a high differential temperature All
between flow pipe and return pipe, for example district heating.
• Underfloor heating systems with thermostatic valves.
• One-pipe heating systems with thermostatic valves or pipe balancing valves.
• Primary circuit pumps in systems with small pressure losses in the primary
circuit. Q
Constant pressure

In pressure boosting systems. All

Constant temperature

All

In systems with a fixed system characteristic.


Examples: Q
• one-pipe heating systems
• boiler shunts Constant differential temperature
• systems with three-way valves
• domestic hot-water circulation.
H

2.2 - 11 kW, 2-pole


3 - 7.5 kW, 4-pole

Q
Constant curve

If an external controller is installed, the pump is able to change from one constant H
curve to another, depending on the value of the external signal.
The pump can also be set to operate according to the maximum or minimum
curve: All
• Use the maximum curve mode in periods in which a maximum flow is required.
This operating mode is suitable e.g. for hot-water priority.
• Use the minimum curve mode in periods in which a minimum flow is required.

30
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
8

TPE Series 1000 pumps


System application Select this control mode Pump type

Constant flow rate

H
In systems requiring a constant flow, independently of pressure drop.
Examples:
• chillers for air-conditioning All
• heating surfaces
• cooling surfaces.

Q set Q

Constant level

H
In systems requiring a constant tank level, independently of the flow rate.
Examples: 2.2 - 11 kW, 2-pole
• process water tanks 3 - 7.5 kW, 4-pole
• boiler condensate tanks.

Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in
2.2 - 11 kW, 2-pole
parallel (two to four pumps) and without the use of external controllers. The "Assist" menu, "Multipump setup"
3 - 7.5 kW, 4-pole
pumps in a multipump system communicate with each other via the wireless
GENIair connection or the wired GENI connection.

Control options
Communication with TPE Series 1000 pumps is
possible via a central building management system,
remote control (Grundfos GO) or control panel.
The purpose of controlling the pump is to monitor and
control the pressure, temperature, flow rate and liquid
level of the system.
For further information on control options of the
pumps, see page 95.

31
9 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

9. TPE2
TPE2

Materials

TM06 7378 3416 - TM06 7379 3416


Fig. 14 TPE2 and TPE2 D pumps

TM05 8200 2113


Technical data
Flow rate: Up to 120 m3/h
Head: Up to 25 m Fig. 15 Sectional drawing of a TPE2 pump
Liquid temperature: -25 to +120 °C (140 °C
for a short period) Material specification
Maximum operating pressure: 16 bar Pos. Component Material EN/DIN
Motor sizes, single-phase: 0.25 to 1.5 kW
Cast iron EN-GJL-250 EN1561
Motor sizes, three-phase: 0.25 to 2.2 kW 1 Pump housing
Stainless steel EN 1.4308
2 Impeller Composite PES-GF30
Construction 3 Neck ring Stainless steel EN 1.4404
Via an external signal from a sensor or a controller, the 4
Pump head/motor Cast iron EN-GJL-250 EN1561
stool Stainless steel EN 1.4308
pumps allow for any configuration and control method
Secondary seals EPDM
required, that is constant pressure, temperature, flow
Rotating seal face Silicon carbide
or level.
Carbon
The permanent-magnet motor has a built-in frequency Stationary seat (resin-impregnated),
converter for continuous adjustment of the pressure to silicon carbide
the flow rate. All pumps are fitted with Grundfos 5 Stub shaft Stainless steel EN 1.4404
permanent-magnet MGE motors that have motor
efficiency class IE5 according to IEC 60034-30-2.
The range is a preset solution for quick and safe
installation.
The pumps are available as single-head, TPE2 and
twin-head, TPE2 D pumps.
The pumps have PN 6, PN 10 or PN 16 flanges.
The pumps are fitted with an unbalanced mechanical
shaft seal.
The power head (motor, pump head and impeller) and
pump housing are held together by a specially
designed clamp. The clamp allows for fast
repositioning of the pump housing and fast service of
the pump.
The twin-head pumps are designed with two parallel
power heads. A flap valve in the common outlet port is
opened by the flow of the pumped liquid and prevents
backflow of liquid into the idle pump head.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
Pumps with stainless steel pump housing, version I,
are suitable for circulation of domestic hot water.

32
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
9
Applications

TPE2
The pumps have integrated speed control for
automatic adaptation of performance to current
conditions.
The energy consumption is thus kept at a minimum.
The pumps can operate at any duty point within the
range between minimum and maximum speed.

HH
[m]
[m]

Maximum speed

TM01 4916 1099


Minimum speed

0
3
0 QQ[m³/h]
[m h]

Fig. 16 Duty range of TPE2

Depending on the application, the pumps offer energy


savings, increased comfort or improved processing.
The pumps can be fitted with sensor types meeting the
requirements mentioned in section Accessories on
page 201.
Constant curve
The pumps are factory-set to constant-curve control
mode.

System application Select this control mode Pump type


In systems with relatively large pressure losses in the distribution pipes and in
air-conditioning and cooling systems. Constant differential-pressure with
• Two-pipe heating systems with thermostatic valves and the following: differential pressure sensor located
– very long distribution pipes in the system
– strongly throttled pipe balancing valves
– differential-pressure regulators
H
– large pressure losses in those parts of the system through which the total
quantity of water flows, for example boiler, heat exchanger and distribution All
pipe up to the first branching.
• primary circuit pumps in systems with large pressure losses in the primary
circuit.
• air-conditioning systems with the following:
– heat exchangers (fan coils)
– cooling ceilings Q
– cooling surfaces.
In systems with relatively small pressure losses in the distribution pipes. Constant differential pressure
• Two-pipe heating systems with thermostatic valves and the following:
– dimensioned for natural circulation H
– small pressure losses in those parts of the system through which the total
quantity of water flows, for example boiler, heat exchanger and distribution
pipe up to the first branching
All
– modified to a high differential temperature between flow pipe and return pipe,
for example district heating.
• Underfloor heating systems with thermostatic valves.
• One-pipe heating systems with thermostatic valves or pipe balancing valves.
• Primary circuit pumps in systems with small pressure losses in the primary
circuit. Q
Constant pressure

In pressure boosting systems. All

33
9 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
TPE2

System application Select this control mode Pump type

Constant temperature and constant


differential temperature

In systems with a fixed system characteristic. H


Examples:
• one-pipe heating systems
All
• boiler shunts
• systems with three-way valves
• domestic hot-water circulation.

Q
Constant curve
If an external controller is installed, the pump is able to change from one constant
curve to another, depending on the value of the external signal. H
The pump can also be set to operate according to the maximum or minimum curve,
like an uncontrolled pump:
• Use the maximum curve mode in periods in which a maximum flow is required. All
This operating mode is for instance suitable for hot-water priority.
• Use the minimum curve mode in periods in which a minimum flow is required.
This operating mode is for instance suitable for manual night setback instead of
automatic night setback.
Q
Constant flow rate

H
In systems requiring a constant flow, independently of pressure drop.
Examples:
• chillers for air-conditioning All
• heating surfaces
• cooling surfaces.

Q set Q

Constant level

H
In systems requiring a constant tank level, independently of the flow rate.
Examples:
All
• process water tanks
• boiler condensate tanks.

Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in
"Assist" menu
parallel (two to four pumps) and twin-head pumps without the use of external All
"Multipump setup"
controllers. The pumps in a multipump system communicate with each other via the
wireless GENIair connection or the wired GENI connection.

34
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
9
Multipump system Backup operation

TPE2
The multipump function enables the control of Backup operation is possible with two pumps of same
single-head pumps connected in parallel or twin-head size and type connected in parallel. Each pump
pumps without the use of external controllers. The requires a non-return valve in series with the pump.
pumps in a multipump system communicate with each One pump is operating continuously. The backup
other via the wireless GENIair connection or the wired pump is operated for a short time each day to prevent
GENI connection. seizing up. If the duty pump stops due to a fault, the
You set a multipump system via a selected pump, that backup pump starts automatically.
is the master pump which is the first selected pump. Pump system:
If you configure two pumps in the system with an • Twin-head pump.
outlet-pressure sensor, both pumps can function as • Two single-head pumps connected in parallel.
master pumps and take over the master pump function The pumps must be of the same type and size.
if the other fails. This provides additional redundancy Each pump requires a non-return valve in series
in the multipump system. with the pump.
You can connect all Grundfos pumps with a wireless
Cascade operation
GENIair connection to the multipump system.
Cascade operation ensures that the pump
The multipump functions are described in the following
performance is automatically adapted to the
sections.
consumption by switching pumps on or off. The system
Alternating operation thus runs as energy-efficiently as possible with a
Alternating operation functions as a duty-standby constant pressure and a limited number of pumps.
operating mode and is possible with two pumps of When a twin-head pump is running in
same size and type connected in parallel. The main constant-pressure control mode, the second pump
purpose of the function is to ensure an even amount of head starts at 90 % and stops at 50 % performance.
running hours and to ensure that the standby pump All pumps in operation will run at equal speed. Pump
takes over if the running pump stops due to an alarm. changeover is automatic and depends on energy,
Each pump requires a non-return valve in series with operating hours and fault.
the pump. Pump system:
You can choose between two alternating operation • Twin-head pump.
modes:
• Two to four single-head pumps connected in
• Alternating operation, time parallel. The pumps must be of the same type and
Pump changeover to the other is based on time. size. Each pump requires a non-return valve in
• Alternating operation, energy series with the pump.
Pump changeover to the other is based on energy Set the control mode to "Const. pressure" or "Const.
consumption. curve".
If the duty pump fails, the other pump takes over
automatically. Control options
Only one pump is operating at a time. The change from Communication with the pumps is possible via a
one pump to the other depends on time or energy. If a central building management system, Grundfos GO or
pump fails, the other pump will take over automatically. control panel.
Pump system: The purpose of controlling TPE2 pumps is to monitor
• Twin-head pump. and control the pressure, temperature, flow rate and
liquid level of the system.
• Two single-head pumps connected in parallel.
The pumps must be of the same type and size. For further information on control options of TPE2
Each pump requires a non-return valve in series pumps, see page 95.
with the pump.

35
10 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

10. TPE3
TPE3

The power head (motor, pump head and impeller) and


pump housing are held together by a specially

TM06 7380 3416 - TM06 7381 3416


designed clamp. The clamp allows for fast
repositioning of the pump housing and fast service of
the pump.
The twin-head pumps are designed with two parallel
power heads. A flap valve in the common outlet port is
opened by the flow of the pumped liquid and prevents
backflow of liquid into the idle pump head.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
Fig. 17 TPE3 and TPE3 D pumps bearing.
Pumps with stainless steel pump housing, version I,
Technical data
are suitable for circulation of domestic hot water.
Flow rate: Up to 120 m3/h
Head: Up to 25 m Materials
Liquid temperature: -25 to +120 °C (140
°C for a short period)
Maximum operating pressure: 16 bar
Motor sizes, single-phase: 0.25 to 1.5 kW
Motor sizes, three-phase: 0.25 to 2.2 kW

Construction
The pumps have built-in differential-pressure and
temperature sensor.
The permanent-magnet motor has a built-in frequency

TM05 8200 2113


converter for continuous adjustment of the pressure to
the flow rate. All pumps are fitted with Grundfos
permanent-magnet MGE motors that have motor
efficiency class IE5 according to IEC 60034-30-2.
The range is a preset solution for quick and safe Fig. 19 Sectional drawing of a TPE3 pump
installation.
Material specification
The pump has a colour display for easy and intuitive
pump setup and with full access to all functions. Pos. Component Material EN/DIN
Cast iron EN-GJL-250 EN1561
1 Pump housing
Stainless steel EN 1.4308
2 Impeller Composite PES-GF30
3 Neck ring Stainless steel EN 1.4404
Pump head/motor Cast iron EN-GJL-250 EN1561
4
stool Stainless steel EN 1.4308
Secondary seals EPDM
Rotating seal face Silicon carbide
TM06 0883 1114

Carbon
Stationary seat (resin-impregnated),
silicon carbide
5 Stub shaft Stainless steel EN 1.4404

Fig. 18 Example of status display for TPE3 pumps

The pumps are available as single-head, TPE3 and


twin-head, TPE3 D pumps.
The pumps have PN 6, PN 10 or PN 16 flanges.
The pumps are fitted with an unbalanced mechanical
shaft seal.

36
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
10
Applications

TPE3
The pumps have integrated speed control for
automatic adaptation of performance to current
conditions.
The energy consumption is thus kept at a minimum.
The pumps can operate at any duty point within the
range between minimum and maximum speed.

HH
[m]
[m]

Maximum speed

TM01 4916 1099


Minimum speed

0
3
0 QQ[m³/h]
[m h]

Fig. 20 Duty range of TPE3

Depending on the application, the pumps offer energy


savings, increased comfort or improved processing.
The pumps are suitable for applications requiring
pressure control.
AUTOADAPT
TPE3 pumps are factory-set to AUTOADAPT which
continuously adapts the pump performance according
to the actual system characteristic.

System application Select this control mode Pump type

"AUTO ADAPT"
Recommended for most heating systems, especially in systems with relatively large
pressure losses in the distribution pipes. See description under proportional H
pressure.
In replacement situations where the proportional-pressure duty point is unknown.
The duty point has to be within the "AUTOADAPT" operating range. During All
operation, the pump automatically makes the necessary adjustment to the actual
system characteristics.
This setting ensures minimum energy consumption and low noise level from the
valves, and therefore reduces operating costs and increases comfort.
Q
The FLOWADAPT control mode is a combination of AUTOADAPT and FLOWLIMIT.
This control mode is suitable for systems where a maximum flow limit, FLOWLIMIT,
is desired. The pump continuously monitors and adjusts the flow, thus ensuring that
the selected FLOWLIMIT is not exceeded. "FLOWADAPT"
Main pumps in boiler applications where a steady flow through the boiler is
required. No extra energy is used for pumping too much liquid into the system. H
In systems with mixing loops, the control mode can control the flow in each loop.
Benefits:
• Enough water for all loops at peak load conditions if each loop has been set to
All
the right maximum flow.
• The dimensioned flow for each zone (required heat energy) is determined by the
flow from the pump.
This value can be set precisely in the FLOWADAPT control mode without the use
of pump throttling valves.
• When the flow is set lower than the balancing valve setting, the pump ramps Q
down instead of losing energy by pumping against a balancing valve.
• Cooling surfaces in air-conditioning systems operate at high pressure and low
flow.

37
10 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
TPE3

System application Select this control mode Pump type


In systems with relatively large pressure losses in the distribution pipes and in
air-conditioning and cooling systems. Proportional pressure
• Two-pipe heating systems with thermostatic valves and the following:
– very long distribution pipes
– strongly throttled pipe balancing valves H
– differential-pressure regulators
– large pressure losses in those parts of the system through which the total
quantity of water flows, for example boiler, heat exchanger and distribution Hset
All
pipe up to the first branching.
• Primary circuit pumps in systems with large pressure losses in the primary Hset
circuit. 2
• Air-conditioning systems with the following:
– heat exchangers (fan coils) Q
– cooling ceilings
– cooling surfaces.
In systems with relatively large pressure losses in the distribution pipes and in Constant differential pressure with
air-conditioning and cooling systems. differential-pressure sensor located
• Two-pipe heating systems with thermostatic valves and the following: in the system
– very long distribution pipes
– strongly throttled pipe balancing valves
– differential-pressure regulators
H
– large pressure losses in those parts of the system through which the total
quantity of water flows, for example boiler, heat exchanger and distribution All
pipe up to the first branching.
• Primary circuit pumps in systems with large pressure losses in the primary
circuit.
• Air-conditioning systems with the following:
– heat exchangers (fan coils)
– cooling ceilings Q
– cooling surfaces.
In systems with relatively small pressure losses in the distribution pipes. Constant differential pressure
• Two-pipe heating systems with thermostatic valves and the following:
– dimensioned for natural circulation H
– small pressure losses in those parts of the system through which the total
quantity of water flows, for example boiler, heat exchanger and distribution
pipe up to the first branching
All
– modified to a high differential temperature between flow pipe and return pipe,
for example district heating.
• Underfloor heating systems with thermostatic valves.
• One-pipe heating systems with thermostatic valves or pipe balancing valves.
• Primary circuit pumps in systems with small pressure losses in the primary
circuit. Q
Constant pressure

In pressure boosting systems. All

Q
Constant temperature and constant
differential temperature

In systems with a fixed system characteristic. H


Examples:
• one-pipe heating systems
• boiler shunts All
• systems with three-way valves
• domestic hot-water circulation.
You can use FLOW LIMIT with advantage to control the maximum circulation flow.

Q
Constant flow rate

H
In systems requiring a constant flow, independently of pressure drop.
Examples:
• chillers for air-conditioning All
• heating surfaces
• cooling surfaces.

Q set Q

38
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
10

TPE3
System application Select this control mode Pump type

Constant level

H
In systems requiring a constant tank level, independently of the flow rate.
Examples:
All
• process water tanks
• boiler condensate tanks.

Q
In systems with pumps operating in parallel.
The multipump function enables the control of single-head pumps connected in
"Assist" menu
parallel (two to four pumps) and twin-head pumps without the use of external All
"Multipump setup"
controllers. The pumps in a multipump system communicate with each other via the
wireless GENIair connection or the wired GENI connection.

39
10 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Multipump system Backup operation


TPE3

The multipump function enables the control of two Backup operation is possible with two pumps of same
pumps connected in parallel without the use of size and type connected in parallel. Each pump
external controllers. The pumps in a multipump system requires a non-return valve in series with the pump.
communicate with each other via the wireless GENIair One pump is operating continuously. The backup
connection or the wired GENI connection. pump is operated for a short time each day to prevent
A multipump system is set via a selected pump, such seizing up. If the duty pump stops due to a fault, the
as the master pump which is the first selected pump. If backup pump starts automatically.
two pumps in the system are configured with an Pump system:
outlet-pressure sensor, both pumps can function as • Twin-head pump.
master pumps and take over the master pump function • Two single-head pumps connected in parallel.
if the other fails. This provides additional redundancy The pumps must be of the same type and size.
in the multipump system. Each pump requires a non-return valve in series
The multipump functions are described in the following with the pump.
sections.
Cascade operation
Alternating operation
Cascade operation ensures that the pump
Alternating operation functions as a duty-standby performance is automatically adapted to the
operating mode and is possible with two pumps of consumption by switching pumps on or off. The system
same size and type connected in parallel. The main thus runs as energy-efficiently as possible with a
purpose of the function is to ensure an even amount of constant pressure and a limited number of pumps.
running hours and to ensure that the standby pump When a twin-head pump is running in
takes over if the running pump stops due to an alarm. constant-pressure control mode, the second pump
Each pump requires a non-return valve in series with head starts at 90 % and stops at 50 % performance. All
the pump. pumps in operation run at equal speed. Pump
You can choose between two alternating operation changeover is automatic and depends on energy,
modes: operating hours and fault.
• Alternating operation, time Pump system:
Pump changeover to the other is based on time. • Twin-head pump.
• Alternating operation, energy • Two to four single-head pumps connected in
Pump changeover to the other is based on energy parallel.
consumption. The pumps must be of the same type and size.
If the duty pump fails, the other pump takes over Each pump requires a non-return valve in series
automatically. with the pump.
Only one pump is operating at a time. The change Set the control mode to "Const. pressure" or "Const.
from one pump to the other depends on time or curve".
energy. If a pump fails, the other pump will
automatically take over. Control options
Pump system: Communication with the pumps is possible via the
• Twin-head pump. control panel, Grundfos GO or a central building
• Two single-head pumps connected in parallel. management system.
The pumps must be of the same type and size. The purpose of controlling the pumps is to monitor and
Each pump requires a non-return valve in series control the pressure, temperature, flow rate of the
with the pump. system.
For further information on control options of the
pumps, see page 95.

40
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
11

11. Overview of functions

Overview of functions
E-pump type

TPE Series TPE Series


TPE3, TPE3 D TPE2, TPE2 D
1000 1000
Control panel E-pump functions
15-22 kW,
2.2 - 11 kW, 2-pole
0.25 - 2.2 kW 0.25 - 2.2 kW
2-pole 11 - 18.5 kW,
4-pole

Settings via advanced control panel

"Setpoint" ● ●1) ●1)


1)
"Operating mode" ● ● ●1)
1)
"Set manual speed" ● ● ●1)
1)
"Control mode" ● ● ●1)
"FLOWLIMIT" ●
"Automatic night setback" ●
"Analog inputs"
"Analog input 1" ● ●1) ●1)
1)
"Analog input 2" ● ● ●1)
1)
"Analog input 3" ● ● ●1)
"Built-in Grundfos sensor" ●
"Pt100/1000 inputs"
"Pt100/1000 input 1" ● ●1) ●1)
"Pt100/1000 input 2" ● ● ●1)
"Digital inputs"
"Digital input 1" ● ●1) ●1)
1)
"Digital input 2" ● ● ●1)
"Digital inputs/outputs"
"Digital in/output 3" ● ●1) ●1)
1)
"Digital in/output 4" ● ● ●1)
1)
"Relay outputs" ● ● ●1)
1)
"Signal relay 1" ● ● ●1)
1)
"Signal relay 2" ● ● ●1)
1)
"Analog output" ● ● ●1)
1)
"Output signal" ● ● ●1)
1)
"Function of analog output" ● ● ●1)
1)
"Controller settings" ● ● ●1)
1)
"Operating range" ● ● ●1)
1)
"Setpoint influence" ● ● ●1)
1)
"External setpoint function" ● ● ●1)
1)
"Predefined setpoints" ● ● ●1)
"Temperature influence" ●
"Monitoring functions" ● ●1) ●1)
1)
"Motor bearing monitoring" ● ● ●1)
1)
"Motor bearing maintenance" ● ● ●1)
1)
"Limit-exceeded function" ● ● ●1)
1)
"Special functions" ● ● ●1)
1)
"Pulse flow meter setup" ● ● ●1)
1)
"Ramps" ● ● ●1)
1)
"Standstill heating" ● ● ●1)
1)
"Communication" ● ● ●1)
1)
"Pump number" ● ● ●1)
1)
"Enable/disable radio communication" ● ● ●1)
1)
"General settings" ● ● ●1)
● Available.
1)
The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.

41
11 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Overview of functions

E-pump type

TPE Series TPE Series


TPE3, TPE3 D TPE2, TPE2 D
1000 1000
Control panel E-pump functions
15-22 kW,
2.2 - 11 kW, 2-pole
0.25 - 2.2 kW 0.25 - 2.2 kW
2-pole 11 - 18.5 kW,
4-pole

Status readings via advanced control panel

"Operating status" ● ●1) ●


"Pump performance" ● ●1) ●1)
"Actual controlled value" ● ●1) ●1)
"Max. curve and duty point" ● ●1)
"Resulting setpoint" ● ●1) ●1)
"Liquid temperature" ●
"Speed" ● ●1) ●1)
"Accumulated flow and specific energy" ● ●1) ●1)
"Power and energy consumption" ● ●1) ●1)
"Measured values" ● ●1) ●1)
"Analog output" ● ●1) ●1)
"Warning and alarm" ● ●1) ●1)
"Heat energy monitor" ●
"Operating log" ● ●1) ●1)
"Fitted modules" ● ●1) ●1)
"Date and time" ● ●1) ●1)
"Product identification" ● ●1) ●1)
"Motor bearing monitoring" ● ●1) ●1)
"Multipump system" ● ●1) ●1)

Setting via standard control panel

"Setpoint" ●
"Start/stop" ●
"Max. curve" ●
"Min. curve" ●
"Alarm reset" ●
"Enable radio communication" ●
Stop Status readings via standard control panel

"Setpoint" ●
"Operating indication" ●
"Fault indication" ●
"Operating mode: MIN, MAX, STOP" ●

Setting via standard control panel

"Setpoint" ●
"Start/stop" ●
"Max. curve" ●
"Min. curve" ●
"Alarm reset" ●

Status readings via standard control panel

"Setpoint" ●
"Operating indication" ●
"Fault indication" ●
"Operating mode: MIN, MAX, STOP" ●
● Available.
1)
The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.

42
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
11

Overview of functions
E-pump type

TPE Series TPE Series


TPE3, TPE3 D TPE2, TPE2 D
1000 1000
Control panel E-pump functions
15-22 kW,
2.2 - 11 kW, 2-pole
0.25 - 2.2 kW 0.25 - 2.2 kW
2-pole 11 - 18.5 kW,
4-pole

Settings via Grundfos GO

"Setpoint" ● ● ● ●
"Operating mode" ● ● ● ●
"Control mode" ● ● ● ●
"Proportional-pressure setup" ●
"FLOWLIMIT" ●
"Automatic night setback" ●
"Temperature influence" ●
"Buttons on product" ● ● ● ●
"Controller" ● ● ● ●
"Operating range" ● ● ● ●
"Ramps" ● ● ●
"Number" ● ● ● ●
"Radio communication" ● ● ●
"Sensor type" ●
"Analog input 1" ● ● ●
"Analog input 2" ● ● ●
"Analog input 3" ● ● ●
"Built-in Grundfos sensor" ●
"Pt100/1000 input 1" ● ● ●
"Pt100/1000 input 2" ● ● ●
"Digital input 1" ● ● ●
"Digital input 2" ● ● ● ●
"Digital in/output 3" ● ● ●
"Digital in/output 4" ● ● ●
"Pulse flow meter" ● ● ●
"Predefined setpoint" ● ● ●
"Analog output" ● ● ●
"External setpoint funct." ● ● ● ●
"Signal relay 1" ● ● ● ●
"Signal relay 2" ● ● ● ●
"Limit 1 exceeded" ● ● ●
"Limit 2 exceeded" ● ● ●
"Standstill heating" ● ● ● ●
"Motor bearing monitoring" ● ● ● ●
"Service" ● ● ●
"Date and time" ● ● ●
"Store settings" ● ● ● ●
"Recall settings" ● ● ● ●
"Undo" ● ● ● ●
"Pump name" ● ● ●
"Connection code" ● ● ●
"Unit configuration" ● ● ● ●
● Available.
1)
The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.

43
11 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Overview of functions

E-pump type

TPE Series TPE Series


TPE3, TPE3 D TPE2, TPE2 D
1000 1000
Control panel E-pump functions
15-22 kW,
2.2 - 11 kW, 2-pole
0.25 - 2.2 kW 0.25 - 2.2 kW
2-pole 11 - 18.5 kW,
4-pole

Status readings via Grundfos GO

"Resulting setpoint" ● ● ● ●
"Actual controlled value" ● ● ● ●
"Motor speed (rpm, %)" ● ● ● ●
"Power consumption" ● ● ● ●
"Energy consumption" ● ● ● ●
"Acc. flow, specific energy" ● ● ●
"Operating hours" ● ● ● ●
"Motor current" ● ● ● ●
"Number of starts" ● ● ● ●
"Liquid temperature" ●
"Pt100/1000 input 1" ● ● ●
"Pt100/1000 input 2" ● ● ●
"Analog output" ● ● ●
"Analog input 1" ● ● ●
"Analog input 2" ● ● ●
"Analog input 3" ● ● ●
"Digital input 1" ● ● ●
"Digital input 2" ● ● ● ●
"Digital in/output 3" ● ● ●
"Digital in/output 4" ● ● ●
"Motor bearing service" ● ● ● ●
"Fitted modules" ● ● ●
"Trend data" ●
"Heat energy monitor" ●

Setting via GENIbus

"Setpoint" ● ● ● ●
"Start/stop" ● ● ● ●
"Max. curve" ● ● ● ●
"Min. curve" ● ● ● ●
"Constant pressure", "proportional pressure" or
● ● ● ●
"constant curve"

Reading via GENIbus

"Setpoint" ● ● ● ●
"Operating indication" ● ● ● ●
"Pump status" ● ● ● ●

Setting via external signal

"Setpoint" ● ● ● ●
"Predefined setpoint" ● ● ●
"Start/stop" ● ● ● ●
"Min./max. curve via digital input" ● ● ● ●
"Alarm resetting" ● ● ●

Reading via external signal

"Fault", "Operation", "Ready", "Pump running",


● ● ● ●
"Bearing lubrication", "Warning" (signal relay)
"Limit exceeded 1 and 2" (signal relay) ● ● ●

Additional functions Additional functions

"Twin-head pump function" ● ● ● ●

Optional functions Optional functions with advanced functional module

● Available.
1)The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.

44
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
11

Overview of functions
E-pump type

TPE Series TPE Series


TPE3, TPE3 D TPE2, TPE2 D
1000 1000
Control panel E-pump functions
15-22 kW,
2.2 - 11 kW, 2-pole
0.25 - 2.2 kW 0.25 - 2.2 kW
2-pole 11 - 18.5 kW,
4-pole

"Real time clock" ● ● ●


"Analog output" ● ● ●
Additional analog, digital and PT100/1000 inputs ● ● ●
● Available.
1)
The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.

45
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

12. User interfaces for TPE pumps


User interfaces for TPE pumps

You can make pump settings by means of the following


user interfaces:
1
Control panels
• TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW,
2
2-pole, 3 - 7.5 kW, 4-pole. See page 46.
• TPE Series 1000 pumps, 15-22 kW, 2-pole and 11 -
18.5 kW, 4-pole. See page 48.
3
• Advanced control panel for TPE3 pumps. See page
49.
4
Remote controls

TM05 4848 3512


Stop
• Grundfos GO. 5
See Grundfos GO on page 54.
If the power supply to the pump is switched off, the
settings will be stored. Fig. 21 Standard control panel

Control panel for TPE2 and TPE Series


1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 Pos. Symbol Description

kW, 4-pole Grundfos Eye


The indicator light shows the operating status
1
of the pump. See page 90 for further
Fitted as information.
Pump variant Option
standard
2 - Light fields for indication of setpoint.
TPE3, TPE3 D - -
Up and down. The buttons change the
TPE2, TPE2 D ● - 3
setpoint.
2.2 - 11 kW, 2-pole
● -
3 - 7.5 kW, 4-pole The button allows radio communication with
TPE Series 1000 Grundfos GO and other products of the same
15-22 kW, 2-pole
- - type.
11 - 18.5 kW, 4-pole
When you try to establish radio
communication between the pump and
4 Grundfos GO or another pump, the green
indicator light in Grundfos Eye on the pump
flashes continuously. Press on the pump
control panel to allow radio communication
with Grundfos GO and other products of the
same type.
The button makes the pump ready for
operation and starts and stops the pump.
Start:
If you press the button when the pump is
stopped, the pump will only start if no other
5 functions with higher priority have been
enabled.
Stop:
If you press the button when the pump is
running, the pump always stops. The "Stop"
text next to the button is on.

46
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Setpoint setting Example: Pump set to maximum curve.

User interfaces for TPE pumps


Set the desired setpoint of the pump by pressing or Figure 24 shows that the top light field is flashing,
. The light fields on the control panel indicates the indicating maximum curve.
setpoint set.
H
Pump in differential-pressure control mode
The following example applies to a pump in an
application where a pressure sensor gives a feedback
to the pump. If you retrofit the sensor to the pump, set
it manually as the pump does not automatically

TM05 4896 2812


register a connected sensor.
Figure 22 shows that the light fields 5 and 6 are
activated, indicating a desired setpoint of 3 m with a
sensor measuring range from 0 to 6 m. The setting Q
range is equal to the sensor measuring range. Fig. 24 Maximum curve duty
m Setting to minimum curve:
6
• Press continuously to change over to the
minimum curve of the pump. The bottom light field
flashes. When the bottom light field is on, press
for 3 seconds until the light field starts flashing.
3 • To change back, press continuously until the
TM05 4894 3512

light field starts flashing.


Example: Pump set to minimum curve.
Figure 25 shows that the bottom light field is flashing,
0 indicating minimum curve.
Fig. 22 Setpoint set to 3 m, differential-pressure control
H
Pump in constant-curve control mode
In constant-curve control mode, the pump performance
is between the maximum and minimum curve of the
pump. See fig. 23.

TM05 4897 2812


H

Q
Fig. 25 Minimum curve duty

Start and stop of pump


Note: If you have stopped the pump by pressing
and the "Stop" text on the control panel is on, you can
only give it free to operation by pressing again.
If you have stopped the pump by pressing , you can
TM05 4895 2812

restart it by pressing or by using Grundfos GO.


Q Start the pump by pressing or by continuously
pressing until the desired setpoint is indicated.
Stop the pump by pressing . When the pump is
Fig. 23 Pump in constant-curve control mode
stopped, the "Stop" text next to the button will
Setting to maximum curve: illuminate. You can also stop the pump by continuously
pressing until none of the light fields are on.
• Press continuously to change over to the
maximum curve of the pump. The top light field You can also stop the pump with Grundfos GO or via a
flashes. When the top light field is on, press for 3 digital input set to "External stop".
seconds until the light field starts flashing.
• To change back, press continuously until the
desired setpoint is indicated.

47
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Resetting of fault indications Setpoint setting


User interfaces for TPE pumps

Reset a fault indication in one of the following ways: Note: You can only set the setpoint when the operating
• Via the digital input if it has been set to "Alarm mode is "Normal".
resetting". Set the desired setpoint by pressing or .
• Briefly press or on the pump. This will not The light fields on the control panel indicates the
change the setting of the pump. setpoint set.
You cannot reset a fault indication by pressing
or if the buttons have been locked. Control mode "Differential-pressure control"
• Switch off the power supply until the indicator lights Example
are off. Figure 27 shows that light fields 5 and 6 are activated,
• Switch the external start/stop input off and then on indicating a desired setpoint of 3.4 m. The sensor
again. measuring range is 0 to 6 m. The setting range is equal
• With Grundfos GO. to the sensor measuring range. See sensor
nameplate.
Control panel for TPE Series 1000 pumps,
15-22 kW, 2-pole and 11 - 18.5 kW, 4-pole
Fitted as
Pump variant Option
standard
TPE3, TPE3 D - -
TPE2, TPE2 D - -

TM03 5845 4006


2.2 - 11 kW, 2-pole
- -
3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole
● -
11 - 18.5 kW, 4-pole

The control panel incorporates the following buttons Fig. 27 Setpoint set to 3.4 m, control mode
and indicator lights: "differential-pressure control"
• buttons, and , for setpoint setting
Control mode "Constant curve"
• light fields, yellow, for setpoint indication
• indicator lights, green (operation) and red (fault). Example
In this control mode, the pump performance is set
within the range from minimum to maximum curve.
Buttons See fig. 28.
Light fields
H
TM05 8590 2613

Indicator lights
TM00 7746 1304

Q
Fig. 26 Control panel for TPE Series 1000 pumps, 15-22
kW, 2-pole and 11 - 18.5 kW, 4-pole

Fig. 28 Pump performance setting, control mode


"Constant curve"

48
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Setting to maximum curve duty

User interfaces for TPE pumps


Press continuously to change over to the maximum 1
curve of the pump. The top light field flashes. See fig.
29.
To change back, press continuously until the
desired setpoint is indicated. 2

H
6 3

TM05 4849 1013


4

TM00 7345 1304


Fig. 31 Advanced control panel

Q Pos. Symbol Description

Fig. 29 Maximum curve duty Grundfos Eye


The indicator light shows the operating status of
1 the pump.
Setting to minimum curve duty See Grundfos Eye on page 90 for further
information.
Press continuously to change over to the minimum
2 - Graphical colour display.
curve of the pump. The bottom light field flashes. See
fig. 30. 3 Press the button to go one step back.
To change back, press continuously until the
Press the buttons to navigate between main
desired setpoint is indicated. menus, displays and digits.
When you change the menu, the display always
H shows the top display of the new menu.
Press the buttons to navigate between
submenusor changes value settings.
Note: If you have disabled the possibility to make
settings with the "Enable/disable settings"
function, then you can enable it again temporarily
by pressing these buttons simultaneously for at
least 5 seconds. See "Buttons on product"
TM00 7346 1304

("Enable/disable settings") on page 81.


4 Press this button to save changed values, reset
alarms and expand the value field.
The button enables radio communication with
Q Grundfos GO and other products of the same
type.
Fig. 30 Minimum curve duty When you try to establish radio communication
between the pump and Grundfos GO or another
Start-stop of pump pump, the green indicator light in Grundfos Eye
flashes. A note also appears in the pump display
Press continuously until the desired setpoint is stating that a wireless device wants to connect to
the pump. Press on the pump control panel to
indicated to start the pump. allow radio communication with Grundfos GO and
Stop the pump by continuously pressing until none other products of the same type.
of the light fields are activated and the green indicator Press the button to make the pump ready for
operation and starts and stops the pump.
light flashes. Start:
If you press the button when the pump is stopped,
Advanced control panel for TPE3 the pump will only start if no other functions with
5 higher priority have been enabled.
Stop:
Fitted as If you press the button when the pump is running,
Pump variant Option
standard the pump is always stopped. When you stop the
TPE3, TPE3 D ● - pump via this button, the icon appears in the
bottom of the display.
TPE2, TPE2 D - ●
2.2 - 11 kW, 2-pole
- ● 6 Press the button to go to the "Home" menu.
3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole
- -
11 - 18.5 kW, 4-pole

49
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"Home" display
User interfaces for TPE pumps

1 2 3 4

Home Status Settings Assist

Setpoint Control mode

5.00 bar Const. pressure

Operating mode Actual controlled value

Normal
4.90 bar

TM06 4516 2415


9 8 7 6 5
Fig. 32 Example of "Home" display

Pos. Symbol Description


"Home"
This menu shows up to four user-defined
parameters. You can select parameters shown as
1
shortcut icon , and when pressing you go
directly to the "Settings" display for the selected
parameter.
"Status"
2 - This menu shows the status of the pump and
system as well as warnings and alarms.
"Settings"
This menu gives access to all setting parameters.
3 - You can make detailed settings of the pump in this
menu.
See Description of selected functions on page 58.
"Assist"
This menu enables assisted pump setup,
4 - provides a short description of the control modes
and offers fault advice.
See "Assist" on page 84.

The symbol indicates that the pump has been


5
stopped via the button.

The symbol indicates that the pump is functioning


6
as master pump in a multipump system.

The symbol indicates that the pump is functioning


7
as a slave pump in a multipump system.

The symbol indicates that the pump is operating


8 in a multipump system. See "Multipump setup"
("Setup of multi-pump system") on page 85.
The symbol indicates that the possibility to make
settings has been disabled for protective reasons.
9
See "Buttons on product" ("Enable/disable
settings") on page 81.

Startup guide
The pump incorporates a startup guide which is started
at the first startup. See "Run start-up guide" on page
83. After the startup guide, the main menus appear in
the display.

50
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Menu overview for advanced control

User interfaces for TPE pumps


Multipump system 2)
2.2 - 11 kW, 2-pole
panel

3 - 7.5 kW, 4-pole


TPE Series 1000
TPE3, TPE3 D

TPE2, TPE2 D
Main menus Status

Multipump system2)
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
TPE Series 1000
TPE3, TPE3 D

TPE2, TPE2 D
"Multipump system" ●
Home
"System operating status" ●
"System performance" ●
"System input power and energy" ●

● ● ● ● "Pump 1, multipump sys." ●


"Pump 2, multipump sys." ●
"Pump 3, multipump sys." ●

Multipump system 2)
2.2 - 11 kW, 2-pole
1)

3 - 7.5 kW, 4-pole


The advanced control panel is available as an option on TPE2 and

TPE Series 1000


TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.
TPE3, TPE3 D

TPE2, TPE2 D
Status 2) Pumps above 11 kW, 2-pole and 7.5 kW, 4-pole have no multipump
function.

"Operating status" ● ●1) ●1) ●


"Operating mode, from" ● ●1) ●1) ●
"Control mode" ● ●1) ●1) ●
"Pump performance" ● ●1) ●1) ●
"Actual controlled value" ● ●1) ●1) ●
"Max. curve and duty point" ● ●
"Resulting setpoint" ● ●1) ●1) ●
"Liquid temperature" ● ●
"Speed" ● ●1) ●1) ●
"Acc. flow and specific energy" ● ●1) ●1) ●
"Power and energy consumption" ● ●1) ●1) ●
"Measured values" ● ●1) ●1) ●
"Analog input 1" ● ●1) ●1) ●
"Analog input 2" ● ●1) ●1) ●
"Analog input 3" ● ●1) ●1) ●
"Pt100/1000 input 1" ● ●1) ●1) ●
"Pt100/1000 input 2" ● ●1) ●1) ●
"Analog output" ● ●1) ●1) ●
"Warning and alarm" ● ●1) ●1) ●
"Actual warning and alarm" ● ●1) ●1) ●
"Warning log" ● ●1) ●1) ●
"Alarm log" ● ●1) ●1) ●
"Heat energy monitor" ● ●
"Heat power" ● ●
"Heat energy" ● ●
"Flow rate" ● ●
"Volume" ● ●
"Hour counter" ● ●
"Temperature 1" ● ●
"Temperature 2" ● ●
"Differential temp." ● ●
"Operating log" ● ●1) ●1) ●
"Operating hours" ● ●1) ●1) ●
"Trend data" ● ●
"Fitted modules" ● ●1) ●1) ●
"Date and time" ● ●1) ●1) ●
"Product identification" ● ●1) ●1) ●
"Motor bearing monitoring" ● ●1) ●1) ●

51
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
User interfaces for TPE pumps

Multipump system 2)
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
TPE Series 1000
TPE3, TPE3 D

TPE2, TPE2 D
Settings Section Page

"Setpoint" ● ●1) ●1) ● "Setpoint" 58


"Operating mode" ● ●1) ●1) ● "Operating mode" 59
"Set manual speed" ● ●1) ●1) ● "Set manual speed" 59
"Set user-defined speed" ● ●1) ●1) ● "Set user-defined speed" 59
"Control mode" ● ●1) ●1) ● "Control mode" 59
"Flow limit" ● ● "FLOWLIMIT" 66
"Automatic night setback" ● ● "Automatic night setback" 67
"Analog inputs" ● ●1) ●1) ● "Analog inputs" 67
"Analog input 1, setup" ● ●1) ●1) ●
"Analog input 2, setup" ● ●1) ●1) ●
"Analog input 3, setup" ● ●1) ●1) ●
"Built-in Grundfos sensor" ● ●
"Pt100/1000 inputs" ● ●1) ●1) ● "Pt100/1000 inputs" 69
1)
"Pt100/1000 input 1, setup" ● ● ●1) ●
"Pt100/1000 input 2, setup" ● ●1) ●1) ●
"Digital inputs" ● ●1) ●1) ● "Digital inputs" 69
"Digital input 1, setup" ● ●1) ●1) ●
"Digital input 2, setup" ● ●1) ●1) ●
"Digital inputs/outputs" ● ●1) ●1) ● "Digital inputs/outputs" 71
"Digital input/output 3, setup" ● ●1) ●1) ●
"Digital input/output 4, setup" ● ●1) ●1) ●
1)
"Relay outputs" ● ● ●1) ● "Signal relays 1 and 2" ("Relay outputs") 72
"Relay output 1" ● ●1) ●1) ●
"Relay output 2" ● ●1) ●1) ●
"Analog output" ● ●1) ●1) ● "Analog output" 72
"Output signal" ● ●1) ●1) ●
"Function of analog output" ● ●1) ●1) ●
1)
"Controller setting" ● ● ●1) ● "Controller" ("Controller settings") 73
"Operating range" ● ●1) ●1) ● "Operating range" 74
"Setpoint influence" ● ●1) ●1) ● "Setpoint influence" 76
"External setpoint function" ● ●1) ●1) ● "External setpoint influence" 75
"Predefined setpoints" ● ●1) ●1) ● "Predefined setpoints" 77
"Temperature influence" ● ● "Temperature influence" 77
"Monitoring functions" ● ●1) ●1) ●
"Motor bearing monitoring" ● ●1) ●1) ● "Motor bearing monitoring" 79
1) 1) "Bearings replaced" ("Motor bearing
"Motor bearing maintenance" ● ● ● ● 80
maintenance")
1) 1)
"Limit-exceeded function" ● ● ● ● "Limit-exceeded function" 78
"Special functions" ● ●1) ●1) ● Special functions 79
"Pulse flow meter setup" ● ●1) ●1) ● "Pulse flowmeter setup" 79
"Ramps" ● ●1) ●1) ● "Ramps" 79
"Standstill heating" ● ●1) ●1) ● "Standstill heating" 79
"Communication" ● ●1) ●1) ● Communication 80
"Pump number" ● ●1) ●1) ● "Number" ("Pump number") 80
"Radio communication" ("Enable/disable
"Enable/disable radio communication" ● ●1) ●1) ● 80
radio comm.")
1) 1)
"General settings" ● ● ● ● General settings 81
1) The advanced control panel is available as an option on TPE2 and TPE Series 1000 pumps, 2.2 - 11 kW, 2-pole, 3 - 7.5 kW, 4-pole.
2)
Pumps above 11 kW, 2-pole and 7.5 kW, 4-pole have no multipump function.

52
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12

User interfaces for TPE pumps


Multipump system 1)
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
TPE Series 1000
TPE3, TPE3 D

TPE2, TPE2 D
Assist Section Page

"Assisted pump setup" ● ● ● ●


"Setup, analog input" ● ● ● ●
"Setting of date and time" ● ● ● ●
"Multipump setup" ● ● ● ●
"Description of control mode" ● ● ● ●
"Assisted fault advice" ● ● ● ●
1) Pumps above 11 kW, 2-pole and 7.5 kW, 4-pole have no multipump function.

53
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Grundfos GO Communication
User interfaces for TPE pumps

The pump is designed for wireless radio or infrared When Grundfos GO initiates communication with the
communication with Grundfos GO. pump, the indicator light in the middle of Grundfos Eye
flashes green. See Priority of settings on page 89.
Grundfos GO enables setting of functions and gives
access to status overviews, technical product Furthermore, on pumps fitted with an advanced control
information and actual operating parameters. panel a text appears in the display saying that a
wireless device is trying to establish connection. Press
Grundfos GO offers the following mobile interfaces, MI.
on the pump in order to establish connection with
Grundfos GO or press to reject connection.
Establish communication using one of these
communication types:
• radio communication
• infrared communication.

1 Radio communication
Radio communication can take place at distances up
2 to 30 metres. The first time Grundfos GO
+ communicates with the pump, you must enable
communication by pressing or on the pump
+ control panel. Later when communication takes place,
TM06 6256 0916

the pump is recognized by Grundfos GO and you can


select the pump from the "List" menu.
Infrared communication
Fig. 33 Grundfos GO communicating with the pump via When communicating via infrared light, Grundfos GO
radio or infrared connection, IR must be pointed at the pump control panel.

Pos. Description
Grundfos MI 204:
Add-on module enabling radio or infrared communication.
You can use MI 204 in conjunction with an Apple iPhone or
1 iPod with Lightning connector, for example fifth generation
or later iPhone or iPod.
MI 204 is also available together with an Apple iPod touch
and a cover.
Grundfos MI 301:
Separate module enabling radio or infrared communication.
2
You can use the module in conjunction with an Android or
iOS-based smart device with Bluetooth connection.

54
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Menu overview for Grundfos GO

User interfaces for TPE pumps


Main menus

Multipump system 1)
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole

15-22 kW, 2-pole


TPE Series 1000

TPE Series 1000


TPE3, TPE3 D

TPE2, TPE2 D
Dashboard

● ● ●

Multipump system 1)
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole

15-22 kW, 2-pole


TPE Series 1000

TPE Series 1000


TPE3, TPE3 D

TPE2, TPE3 D
Status Section Page

"System mode" ●
"Resulting setpoint" ● ● ●
"Resulting system setpoint" ●
"Actual setpoint" ●
"External setpoint" ●
"Actual controlled value" ● ● ● ●
"Sensor value" ●
"Motor speed (rpm, %)" ● ● ● ●
"Power consumption" ● ● ● ●
"Power consumption system" ●
"Energy consumption" ● ● ● ●
"Energy consumption system" ●
"Acc. flow, specific energy" ● ● ● ●
"Operating hours" ● ● ● ●
"Motor current" ● ● ● ● ●
"Number of starts" ● ● ● ● ●
"Liquid temperature" ●
"Analog input 1" ● ● ●
"Analog input 2" ● ● ●
"Analog input 3" ● ● ●
"Pt100/1000 input 1" ● ● ●
"Pt100/1000 input 2" ● ● ●
"Analog output" ● ● ●
"Digital input 1" ● ● ●
"Digital input 2" ● ● ● ●
"Digital in/output 3" ● ● ●
"Digital in/output 4" ● ● ●
"Motor bearing service" ● ● ● ● ●
"Fitted modules" ● ● ● ●
"Trend data" ●
"Heat energy monitor" ●
"Controlled from" ●
"Pump1" ●
"Pump2" ●
"Pump3" ●
"Pump4" ●

1)
Pumps above 11 kW, 2-pole and 7.5 kW, 4-pole have no multipump function.

55
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
User interfaces for TPE pumps

Multipump system 1)
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole

15-22 kW, 2-pole


TPE Series 1000

TPE Series 1000


TPE3, TPE3 D

TPE2, TPE2 D
Settings Section Page

"Setpoint" ● ● ● ● ● "Setpoint" 58
"Operating mode" ● ● ● ● ● "Operating mode" 59
"Set user-defined speed" ● ● ● ● ● "Set user-defined speed" 59
"Control mode" ● ● ● ● ● "Control mode" 59
"Proportional-pressure setup" ● "Proportional-pressure setup" 66
"Flow limit" ● "FLOWLIMIT" 66
"Automatic night setback" ● "Automatic night setback" 67
"Temperature influence" ● "Temperature influence" 77
"Buttons on product" ("Enable/disable
"Buttons on product" ● ● ● ● ● 81
settings")
"Controller" ● ● ● ● ● "Controller" ("Controller settings") 73
"Operating range" ● ● ● ● ● "Operating range" 74
"Ramps" ● ● ● "Ramps" 79
"Number" ● ● ● ● "Number" ("Pump number") 80
"Radio communication" ("Enable/disable
"Radio communication" ● ● ● 80
radio comm.")
"Sensor type" ● "Sensor type" 67
"Analog input 1" ● ● ●
"Analog input 2" ● ● ● "Analog inputs" 67
"Analog input 3" ● ● ●
"Built-in Grundfos sensor" ● "Built-in Grundfos sensor" 68
"Pt100/1000 input 1" ● ● ●
"Pt100/1000 inputs" 69
"Pt100/1000 input 2" ● ● ●
"Digital input 1" ● ● ●
"Digital inputs" 69
"Digital input 2" ● ● ● ●
"Digital in/output 3" ● ● ●
"Digital inputs/outputs" 71
"Digital in/output 4" ● ● ●
"Pulse flowmeter" ● ● ●
"Predefined setpoint" ● ● ● ● "Predefined setpoints" 77
"Analog output" ● ● ● "Analog output" 72
"External setpoint funct." ● ● ● ● "External setpoint influence" 75
"Signal relay 1" ● ● ● ●
"Signal relays 1 and 2" ("Relay outputs") 72
"Signal relay 2" ● ● ● ●
"Limit 1 exceeded " ● ● ● ●
"Limit-exceeded function" 78
"Limit 2 exceeded " ● ● ● ●
"Alternating operation, time" ●
"Time for pump change over" ●
"Standstill heating" ● ● ● ● "Standstill heating" 79
"Motor bearing monitoring" ● ● ● ● "Motor bearing monitoring" 79
"Service" ● ● ● "Service" 80
"Date and time" ● ● ● ● "Date and time" 81
"Store settings" ● ● ● ● "Store settings" ("Store actual settings") 82
"Recall settings" ● ● ● ● "Recall settings" ("Recall stored settings") 82
"Undo" ● ● ● ● ● "Undo" 82
"Pump name" ● ● ● ● "Pump name" 82
"Connection code" ● ● ● ● "Connection code" 83
"Unit configuration" ● ● ● ● "Unit configuration" ("Units") 81

56
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12

User interfaces for TPE pumps


Multipump system 1)
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole

15-22 kW, 2-pole


TPE Series 1000

TPE Series 1000


TPE3, TPE3 D

TPE2, TPE2 D
Alarms and warnings Section Page

"Alarm log" ● ● ● ● "Alarm log" 83


"Warning log" ● ● ● ● "Warning log" 84
"Reset alarm" button ● ● ● ● "Warning log"

1) Pumps above 11 kW, 2-pole and 7.5 kW, 4-pole have no multipump function.

Multipump system 1)
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole

15-22 kW, 2-pole


TPE Series 1000

TPE Series 1000


TPE3, TPE3 D

TPE2, TPE2 D
Assist Section Page

"Assisted pump setup" ● ● ● ●


"Assisted fault advice" ● ● ● ●
"Multipump setup" ("Setup of multi-pump
"Multipump setup" ● ● ● ● 85
system")
1) Pumps above 11 kW, 2-pole and 7.5 kW, 4-pole have no multipump function.

57
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Description of selected functions "Setpoint"


User interfaces for TPE pumps

Pump variant "Setpoint"


"Heat energy monitor"
TPE3, TPE3 D ●
"Heat energy TPE2, TPE2 D ●
Pump variant 2.2 - 11 kW, 2-pole
monitor" ●
3 - 7.5 kW, 4-pole
TPE3, TPE3 D ● TPE Series 1000
15-22 kW, 2-pole
TPE2, TPE2 D - ●
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole
-
TPE Series 1000
3 - 7.5 kW, 4-pole You can set the setpoint for all control modes, except
15-22 kW, 2-pole AUTOADAPT and FLOWADAPT, in this submenu when
-
11 - 18.5 kW, 4-pole
you have selected the desired control mode. See
The heat energy monitor is a monitoring function that "Control mode" on page 59.
calculates the heat energy consumption within a
Factory setting
system. The built-in flow estimation needed for the
calculation has an inaccuracy of ± 10 % of the See section 13. Factory settings of E-pumps.
maximum flow in the area down to 10 % flow and down
to 12.5 % of the maximum head. The calculations are
based on water at a temperature of 20 °C. Also, the
temperature measurements needed for the calculation
have some inaccuracy depending on the sensor type.
Therefore, you cannot use the heat energy value for
billing purposes. However, the value is perfect for
optimization purposes in order to prevent excessive
energy costs caused by system imbalances.
The heat energy monitor requires an additional
temperature sensor installed in the flow pipe or return
pipe depending on where the pump is installed.
Use the analog inputs and/or Pt100/1000 inputs for
measuring the temperatures used for calculation by
the heat energy monitor.
The used inputs must not be set to "Not active" and
one of the measuring parameters must be set to
"Temperature 2".

kWh

t
F
TM06 1182 1814

t
R

tF: Flow pipe temperature


tR: Return pipe temperature

Fig. 34 Example: Pump installed in the flow pipe and


additional temperature sensor installed in the
return pipe.

58
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Operating mode" "Set manual speed"

User interfaces for TPE pumps


Pump variant "Operating mode" Pump variant "Set manual speed"
TPE3, TPE3 D ● TPE3, TPE3 D ●
TPE2, TPE2 D ● TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole 2.2 - 11 kW, 2-pole
● ●
3 - 7.5 kW, 4-pole 3 - 7.5 kW, 4-pole
TPE Series 1000 TPE Series 1000
15-22 kW, 2-pole 15-22 kW, 2-pole
● -
11 - 18.5 kW, 4-pole 11 - 18.5 kW, 4-pole

Possible operating modes: This menu is only available in the advanced control
• "Normal" panel. With Grundfos GO, you set the speed via the
The pump runs according to the selected control "Setpoint" menu.
mode. You can set the pump speed in % of the maximum
• "Stop" speed. When you have set the operating mode to
The pump stops. "Manual", the pump starts running at the set speed.
• "Min." The speed can then be changed manually via
Use the minimum curve mode in periods in which a Grundfos GO or via the advanced control panel.
minimum flow is required.
This operating mode is for instance suitable for
"Set user-defined speed"
manual night setback if you do not want to use You can set the motor speed in % of the maximum
automatic night setback. speed. When you have set the operating mode to
• "Max." "User-defined speed", the motor runs at the set speed.
Use the maximum curve mode in periods in which a
maximum flow is required. "Control mode"
This operating mode is for instance suitable for
Pump variant "Control mode"
hot-water priority.
TPE3, TPE3 D ●
• "Manual" TPE2, TPE2 D ●
The pump is operating at a manually set speed. 2.2 - 11 kW, 2-pole

In "Manual" the setpoint via bus is overruled. See TPE Series 1000
1.1 - 7.5 kW, 4-pole
"Set manual speed" on page 59. 15-22 kW, 2-pole

11 - 18.5 kW, 4-pole
• "User-defined speed"
The motor is operating at a speed set by the user. Note: Not all control modes are available for all pump
See section "Set user-defined speed" on page 59. variants.
All operating modes are illustrated in the fig. 35. Possible control modes:
• "AUTOADAPT"
H
Max.
• "FLOWADAPT"
Normal • "Prop. press." (proportional pressure)
• "Const. pressure" (constant pressure)
Normal • "Const. temp." (constant temperature)
Manual
• "Con. diff. press." (constant differential pressure)
TM06 4024 1515

Min.
• "Con. diff. temp." (constant differential temperature)
• "Const. flow rate" (constant flow rate)
Stop
Q
• "Const. level" (constant level)
• "Const. other val." (constant other value)
Fig. 35 Operating modes
• "Const. curve" (constant curve).
Factory setting You can change the setpoint for all control modes,
See section 13. Factory settings of E-pumps. except AUTOADAPT and FLOWADAPT, in the "Setpoint"
submenu under "Settings" when you have selected the
desired control mode.
Factory setting
See section 13. Factory settings of E-pumps.

59
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"AUTOADAPT" "FLOWADAPT"
User interfaces for TPE pumps

Pump variant "AUTOADAPT" Pump variant "FLOW ADAPT"


TPE3, TPE3 D ● TPE3, TPE3 D ●
TPE2, TPE2 D - TPE2, TPE2 D -
2.2 - 11 kW, 2-pole 2.2 - 11 kW, 2-pole
- -
3 - 7.5 kW, 4-pole 3 - 7.5 kW, 4-pole
TPE Series 1000 TPE Series 1000
15-22 kW, 2-pole 15-22 kW, 2-pole
- -
11 - 18.5 kW, 4-pole 11 - 18.5 kW, 4-pole

The AUTOADAPT control mode continuously adapts the When you select FLOWADAPT, the pump runs
pump performance according to the actual system AUTOADAPT and ensures that the flow never exceeds
characteristic. the entered FLOWLIMIT value.
Manual setting of the setpoint is not possible. The setting range for FLOWLIMIT is 25 to 90 % of the
Qmax of the pump.
H The factory setting of the FLOWLIMIT is the flow where
the AUTOADAPT factory setting meets the maximum
curve. See fig. 37.
Hfac Hset1
H 25 % 90 % Q
Qmax
max
A1

Setting range
TM05 7910 1613

Hauto_min Hset2
A3 A2
HHfac
fac

Q
Fig. 36 AUTOADAPT HHauto_min
auto_min

TM05 7912 1613


When the AUTOADAPT control mode has been
enabled, the pump will start with the factory setting, Q
Hfac is equal to Hset1, and then adjust its performance Qfac
Q fac
to A1. See fig. 36. Fig. 37 FLOWADAPT
When the pump registers a lower head on the
maximum curve, A2, the AUTOADAPT function
automatically selects a correspondingly lower control
curve, Hset2. If the valves in the system close, the
pump adjusts its performance to A3.

A1: Original duty point.


A2: Lower registered head on the max. curve.
A3: New duty point after AUTOADAPT control.
Hset1: Original setpoint setting.
Hset2: New setpoint after AUTOADAPT control.
Hfac: Factory setting.
Hauto_min: A fixed value of 1.5 m.
The AUTOADAPT control mode is a form of
proportional-pressure control where the control curves
have a fixed origin, Hauto_min.
The AUTOADAPT control mode has been developed
specifically for heating systems and we do not
recommend that you use it for air-conditioning and
cooling systems.

60
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Proportional pressure" "Constant pressure"

User interfaces for TPE pumps


"Proportional Pump variant "Constant pressure"
Pump variant
pressure"
TPE3, TPE3 D ●
TPE3, TPE3 D ● TPE2, TPE2 D ●
TPE2, TPE2 D - 2.2 - 11 kW, 2-pole

2.2 - 11 kW, 2-pole 3 - 7.5 kW, 4-pole
- TPE Series 1000
3 - 7.5 kW, 4-pole 15-22 kW, 2-pole
TPE Series 1000 ●
15-22 kW, 2-pole 11 - 18.5 kW, 4-pole
-
11 - 18.5 kW, 4-pole
We recommend this control mode if the pump is to
The head of the pump is reduced at decreasing water deliver a constant pressure, independently of the flow
demand and increased at rising water demand. See in the system. The pump maintains a constant
fig. 38. pressure independently of the flow rate. See fig. 40.
This control mode is especially suitable in systems
with relatively large pressure losses in the distribution H
pipes. The head of the pump increases proportionally
to the flow in the system to compensate for the large
pressure losses in the distribution pipes.
You can set the setpoint with an accuracy of 0.1 m.
The head against a closed valve is half the setpoint.
For more information about settings, see

TM05 7901 1613


"Proportional-pressure setup" on page 66.

H
Q
Fig. 40 "Constant pressure"

This control mode requires an external pressure


Hset
H set
sensor as shown in the examples below. You can set
the pressure sensor in the "Assist" menu. See
TM05 7909 1613

Hset "Assisted pump setup" on page 84.


H set

2 Examples
• One external pressure sensor.
Q
Fig. 38 "Proportional pressure"

Example
p
• Factory-fitted differential-pressure sensor.
p

p
Fig. 41 "Constant pressure"

Fig. 39 "Proportional pressure" Controller settings


Controller settings For recommended controller settings, see "Controller"
("Controller settings") on page 73.
For recommended controller settings, see "Controller"
("Controller settings") on page 73.

61
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"Constant temperature" "Constant differential pressure"


User interfaces for TPE pumps

"Constant "Constant differential


Pump variant Pump variant
temperature" pressure"
TPE3, TPE3 D ● TPE3, TPE3 D ●
TPE2, TPE2 D ● TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole 2.2 - 11 kW, 2-pole
● ●
3 - 7.5 kW, 4-pole 3 - 7.5 kW, 4-pole
TPE Series 1000 TPE Series 1000
15-22 kW, 2-pole 15-22 kW, 2-pole
● ●
11 - 18.5 kW, 4-pole 11 - 18.5 kW, 4-pole

This control mode ensures a constant temperature. The pump maintains a constant differential pressure,
Constant temperature is a comfort control mode that independently of the flow in the system. See fig. 44.
you can use in domestic hot-water systems to control This control mode is primarily suitable for systems with
the flow to maintain a fixed temperature in the system. relatively small pressure losses.
See fig. 42.
H
H

TM05 7901 1613


TM05 7900 1613

Q
Q Fig. 44 "Constant differential pressure"
Fig. 42 "Constant temperature"
This control mode requires either an internal or
This control mode requires either an external external differential-pressure sensor or two external
temperature sensor as shown in the examples below: pressure sensors. See the examples below.
Examples
• Factory-fitted temperature sensor. Only TPE3,
TPE3 D.

• One external temperature sensor.

Fig. 43 Constant temperature

Controller settings
For recommended controller settings, see "Controller"
("Controller settings") on page 73.

62
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Constant differential temperature"

User interfaces for TPE pumps


Examples
• Factory-fitted differential-pressure sensor, only "Constant
Pump variant differential
TPE3, TPE3 D. temperature"
TPE3, TPE3 D ●
TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole
p ●
3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole

• One external differential-pressure sensor. 11 - 18.5 kW, 4-pole
The pump uses the input from the sensor to control
The pump maintains a constant differential
the differential pressure. You can set the sensor
temperature in the system and the pump performance
manually or by using the "Assist" menu. See
is controlled according to this. See fig. 46.
"Assisted pump setup" on page 84.
H

p △t
p

TM05 7954 1713


• Two external pressure sensors.
Constant differential-pressure control is achievable
with two pressure sensors. The pump uses the
inputs from the two sensors and calculates the Q
differential pressure. The sensors must have the
Fig. 46 "Constant differential temperature"
same unit and must be set as feedback sensors.
You can set the sensors manually, sensor by sensor, This control mode requires either two temperature
or by using the "Assist" menu. See "Assisted pump sensors or one external differential-temperature
setup" on page 84. sensor. See the examples below.
The temperature sensors can either be analog sensors
p p
connected to two of the analog inputs or two
Pt100/Pt1000 sensors connected to the Pt100/1000
p inputs, if these are available on the specific pump.
p p
p Set the sensor in the "Assist" menu under "Assisted
pump setup". See "Assisted pump setup" on page 84.
Fig. 45 "Constant differential pressure"

Controller settings
For recommended controller settings, see "Controller"
("Controller settings") on page 73.

63
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"Constant flow rate"


User interfaces for TPE pumps

Examples
• Factory-fitted temperature sensor and an external Pump variant "Constant flow rate"
temperature sensor. Only TPE3, TPE3 D. TPE3, TPE3 D ●
TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole

3 - 7.5 kW, 4-pole
t TPE Series 1000
15-22 kW, 2-pole

t 11 - 18.5 kW, 4-pole

The pump maintains a constant flow in the system,


t
independently of the head. See fig. 48.
• Two external temperature sensors. Not available for
TPE 15-22 kW 2-pole and 11 - 18.5 kW 4-pole. H
Constant differential-temperature control is
achievable with two temperature sensors. The pump
uses the inputs from the two sensors and calculates
the differential temperature.
The sensors must have the same unit and must be
set as feedback sensors. You can set the sensors

TM05 7955 1713


manually, sensor by sensor, or by using the "Assist"
menu. See "Assisted pump setup" on page 84.

Q
Q set
t
Fig. 48 "Constant flow rate"
t
This control mode requires an external flow sensor.
t
See the example below.
• One external differential-temperature sensor.
Example
The pump uses the input from the sensor to control
• One external flow sensor.
the differential temperature.
You can set the sensor manually or by using the
"Assist" menu. See "Assisted pump setup" on page Q
84.
Fig. 49 Constant flow rate

Controller settings
t For recommended controller settings, see "Controller"
("Controller settings") on page 73.

Fig. 47 "Constant differential temperature"

Controller settings
For recommended controller settings, see "Controller"
("Controller settings") on page 73.

64
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Constant level"

User interfaces for TPE pumps


Examples
Pump variant "Constant level" • One external level sensor.
TPE3, TPE3 D ● – emptying function.
TPE2, TPE2 D ● L
2.2 - 11 kW, 2-pole

3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole

The pump maintains a constant level, independently of


the flow rate. See fig. 50.
• One external level sensor.
H – filling function.
L

TM05 7941 1613

Fig. 51 Constant level

Controller settings
Q For recommended controller settings, see "Controller"
Fig. 50 "Constant level" ("Controller settings") on page 73.

This control mode requires an external level sensor. "Constant other value"
The pump can control the level in a tank in two ways: "Constant other
Pump variant
• As an emptying function where the pump draws the value"
liquid from the tank. TPE3, TPE3 D ●
TPE2, TPE2 D ●
• As a filling function where the pump pumps the
2.2 - 11 kW, 2-pole
liquid into the tank. 3 - 7.5 kW, 4-pole

TPE Series 1000
See fig. 51. 15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole
The type of level control function depends on the
setting of the built-in controller. See "Controller" Any other value is kept constant.
("Controller settings") on page 73. Use this control mode if you want to control a value
which is not available in the "Control mode" menu.
Connect a sensor measuring the controlled value to
one of the analog inputs of the pump. The controlled
value will be shown in percentage of sensor range.

65
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"Constant curve" "Proportional-pressure setup"


User interfaces for TPE pumps

Pump variant "Constant curve" "Proportional-pressure


Pump variant
TPE3, TPE3 D ● setup"
TPE2, TPE2 D ● TPE3, TPE3 D ●
2.2 - 11 kW, 2-pole TPE2, TPE2 D -

3 - 7.5 kW, 4-pole 2.2 - 11 kW, 2-pole
TPE Series 1000 -
15-22 kW, 2-pole 3 - 7.5 kW, 4-pole
● TPE Series 1000
11 - 18.5 kW, 4-pole 15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole
You can set the pump to operate according to a
constant curve, like an uncontrolled pump. See fig. 52. "Control-curve function"
You can set the desired speed can be set in % of You can set the curve either to quadratic or linear.
maximum speed in the range from 13 to 100 %.
"Zero-flow head"
You can set this value in % of the setpoint. With a
H setting of 100 %, the control mode is equal to constant
differential pressure.

"FLOWLIMIT"
Pump variant "FLOWLIMIT"
TPE3, TPE3 D ●
TPE2, TPE2 D -
2.2 - 11 kW, 2-pole
TM05 7957 1713

-
3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole

Q FLOWLIMIT
Fig. 52 "Constant curve" • Enable FLOWLIMIT function.
• Set FLOWLIMIT.
Depending on the system characteristic and the duty
point, the 100 % setting may be slightly smaller than H 25 % 90 % Q max
the actual maximum curve of the pump even though
the display shows 100 %. This is due to the power and Setting range
pressure limitations built into the pump. The deviation
varies according to pump type and pressure loss in the
pipes.

H [%]

TM05 7908 1613


100 %
Limited maximum curve
Q
Q limit Q max
Fig. 54 FLOWLIMIT
TM05 7913 1613

You can combine the FLOWLIMIT function with the


following control modes:
80 % Q [m3/h]
• Proportional pressure
• Constant differential pressure
Fig. 53 Power and pressure limitations influencing the
maximum curve • Constant differential temperature
• Constant temperature
Controller settings • Constant curve.
For recommended controller settings, see "Controller" A flow-limiting function ensures that the flow never
("Controller settings") on page 73. exceeds the entered FLOWLIMIT value.
The setting range for FLOWLIMIT is 25 to 90 % of the
Qmax of the pump.
The factory setting of the FLOWLIMIT is the flow where
the AUTOADAPT factory setting meets the maximum
curve. See fig. 37.

66
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Automatic night setback" "Analog inputs"

User interfaces for TPE pumps


"Automatic night Pump variant "Analog inputs"
Pump variant
setback"
TPE3, TPE3 D ●
TPE3, TPE3 D ● TPE2, TPE2 D ●
TPE2, TPE2 D - 2.2 - 11 kW, 2-pole

2.2 - 11 kW, 2-pole 3 - 7.5 kW, 4-pole
- TPE Series 1000
3 - 7.5 kW, 4-pole 15-22 kW, 2-pole
TPE Series 1000 -
15-22 kW, 2-pole 11 - 18.5 kW, 4-pole
-
11 - 18.5 kW, 4-pole

Once you have enabled automatic night setback, the Function Terminals*

pump automatically changes between normal duty and "Analog input 1, setup" 4
night setback, duty at low performance. "Analog input 2, setup" 7
"Analog input 3, setup" 14
Changeover between normal duty and night setback
depends on the flow-pipe temperature. * See Connection terminals, advanced functional module, FM 300 on
page 115.
The pump automatically changes over to night setback
when the built-in sensor registers a flow-pipe Set the analog input for a feedback sensor via the
temperature drop of more than 10 to 15 °C within "Assisted pump" setup menu. See "Assisted pump
approximately two hours. The temperature drop must setup" on page 84.
be at least 0.1 °C/min. If you want to set an analog input for other purposes,
Changeover to normal duty takes place without a time you can do this manually.
lag when the temperature has increased by You can set the analog inputs via the "Setup, analog
approximately 10 °C. input" menu. See "Setup, analog input" on page 85.
Note: You cannot enable automatic night setback If you perform the manual setting via Grundfos GO,
when the pump is in constant-curve mode. you need to enter the menu for the analog input under
the "Settings" menu.
"Sensor type"
Function
Pump variant "Sensor type" You can set the analog inputs to these functions:
TPE3, TPE3 D - • "Not active"
TPE2, TPE2 D -
• "Feedback sensor"
2.2 - 11 kW, 2-pole
-
3 - 7.5 kW, 4-pole • "Ext. setpoint infl."
TPE Series 1000
15-22 kW, 2-pole
● See "External setpoint influence" on page 75.
11 - 18.5 kW, 4-pole
• "Other function".
The setting of the sensor is only relevant in the case of
controlled operation.
Select among the following values:
• Sensor output signal
0-10 V
0-20 mA
4-20 mA.
• Unit of measurement of sensor:
bar, mbar, m, kPa, psi, ft, m3/h, m3/s, l/s, gpm, °C,
°F, %.
• Sensor measuring range.

67
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Measured parameter Setting two sensors for differential measurement


User interfaces for TPE pumps

Select one of the parameters, that is the parameter to In order to measure the difference of a parameter
be measured in the system by the sensor connected to between two points, set the corresponding sensors as
the actual analog input. See fig. 55. follows:

5 Analog input for Analog input for


Parameter
1 DPT 3 13
11
6 14 sensor 1 sensor 2
Q
PT PT TT PT TT Differential pressure, Differential pressure,
Pressure, option 1
12 inlet outlet
2 4 7 8 16 15
DPT DPT Q DPT DTT Pressure, option 2 Pressure 1, external Pressure 2, external
PT TT
Flow Pump flow Flow, external
Temperature Temperature 1 Temperature 2

9 10 If you want to use the control mode "constant


LT LT differential pressure", you must choose the function

TM06 2328 3914


"Feedback sensor" for the analog input of both
sensors.

"Built-in Grundfos sensor"


Fig. 55 Overview of sensor locations
"Built-in Grundfos
Pump variant
sensor"
Sensor function, measured parameter Pos.
TPE3, TPE3 D ●
"Inlet pressure" 1 TPE2, TPE 2 D -
"Diff. press., inlet" 2 2.2 - 11 kW, 2-pole
-
"Liquid temp." 3 3 - 7.5 kW, 4-pole
TPE Series 1000
"Diff. press.,outlet" 4 15-22 kW, 2-pole
-
"Diff. press.,pump" 5 11 - 18.5 kW, 4-pole
"Operating mode" 6
You can select the function of the built-in sensor in the
"Press. 2, external" 7
"Diff. press., ext." 8
"Built-in Grundfos sensor" menu.
"Other parameter" 9 Set the "Built-in Grundfos sensor" via the "Assisted
"Feed tank level" 10 pump setup" menu. See "Assisted pump setup" on
"Pump flow" 11 page 84.
"Flow, external" 12
If you perform the setting manually in the advanced
"Liquid temp." 13
control panel, you must enter the "Analog inputs" menu
"Temperature 1" 14
"Temperature 2" 15
under the "Settings" menu in order to access the
"Date and time" 16 "Built-in Grundfos sensor" menu.
"Ambient temp." Not shown If you perform the setting manually via Grundfos GO,
"Other parameter" Not shown you need to enter the menu for the "Built-in Grundfos
sensor" under the "Settings" menu.
"Unit"
Function
Available measuring units:
You can set the built-in sensor to these functions:
Parameter Possible units • "Grundfos diff.-pressure sensor"
Pressure bar, m, kPa, psi, ft
- "Not active"
Pump flow m3/h, l/s, yd3/h, gpm
- "Feedback sensor"
Liquid temperature °C, °F
Other parameter % - "Setpoint influence"
- "Other function".
Electrical signal
• "Grundfos temperature sensor"
Select signal type:
- "Not active"
• "0.5 - 3.5 V"
- "Feedback sensor"
• "0-5 V"
- "Setpoint influence"
• "0-10 V"
- "Other function".
• "0-20 mA"
• "4-20 mA". Factory setting
See section 13. Factory settings of E-pumps.
Sensor range, minimum value
Set the minimum value of the connected sensor.
Sensor range, maximum value
Set the maximum value of the connected sensor.
Factory setting
See section 13. Factory settings of E-pumps.

68
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Pt100/1000 inputs" "Digital inputs"

User interfaces for TPE pumps


Pump variant "Pt100/1000 inputs" Pump variant "Digital inputs"
TPE3, TPE3 D ● TPE3, TPE3 D ●
TPE2, TPE2 D ● TPE2, TPE 2 D ●
2.2 - 11 kW, 2-pole 2.2 - 11 kW, 2-pole
● ●
3 - 7.5 kW, 4-pole 3 - 7.5 kW, 4-pole
TPE Series 1000 TPE Series 1000
15-22 kW, 2-pole 15-22 kW, 2-pole
- ●
11 - 18.5 kW, 4-pole 11 - 18.5 kW, 4-pole

TPE2, TPE3 pumps and TPE Series 1000 2.2 - 11


Function Terminals*
kW, 2-pole and 3 - 7.5 kW, 4-pole pumps
"Pt100/1000 input 1, setup" 17 and 18
"Pt100/1000 input 2, setup" 18 and 19 Function Terminals*
* See Connection terminals, advanced functional module, FM 300 on "Digital input 1, setup" 2 and 6
page 115. "Digital input 2, setup" 1 and 9

Set the Pt100/1000 input for a feedback sensor via the * See Connection terminals, advanced functional module, FM 300 on
Assisted pump setup menu. See "Assisted pump page 115.

setup" on page 84. To set up a digital input, make the settings below.
If you want to set a Pt100/1000 input for other
Function
purposes, you can do this manually.
You can set the analog inputs via the "Setup, analog Select one of these functions:
input" menu. See "Setup, analog input" on page 85. • "Not active"
If you perform the manual setting via Grundfos GO, When set to "Not active", the input has no function.
you need to enter the menu for the Pt100/1000 input • "External stop"
under the Settings menu. When the input is deactivated, open circuit, the
Function pump stops.
You can set the Pt100/1000 inputs to these functions: • "Min." (minimum speed)
When the input is activated, the pump runs at the
• "Not active"
set minimum speed.
• "Feedback sensor"
• "Max." (maximum speed)
• "Ext. setpoint infl." When the input is activated, the pump runs at the
See "External setpoint influence" on page 75. set maximum speed.
• "Other function". • "User-defined speed"
Measured parameter When the input is activated, the motor runs at a
speed set by the user.
Select one of the parameters, such as the parameter
to be measured in the system by the Pt100/1000 • "External fault"
sensor connected to the actual Pt100/1000 input. See When the input is activated, a timer starts. If the
fig. 56. input is activated for more than 5 seconds, the
pump stops and a fault is indicated. This function
1 2 depends on input from external equipment.
TM06 4012 1515

TT TT
• "Alarm resetting"
4 3 When the input is activated, a possible fault
DTT TT indication is reset.

Fig. 56 Overview of Pt100/1000 sensor locations

Parameter Pos.
"Liquid temp." 1
"Temperature 1" 2
"Temperature 2" 3
"Ambient temp." Not shown

Measuring range
-50 to +204 °C.
Factory setting
See section 13. Factory settings of E-pumps.

69
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

• "Dry running" Duration timer mode


User interfaces for TPE pumps

When this function has been selected, lack of inlet Select the mode. See fig. 57.
pressure or water shortage can be detected.
• "Not active"
When lack of inlet pressure or water shortage, dry
running, is detected, the pump stops. The pump • active with interrupt, mode A
cannot restart as long as the input is activated. • active without interrupt, mode B
This requires the use of an accessory, such as • active with after-run, mode C.
these: Select the duration time, T2.
– a pressure switch installed on the inlet side of the It is the time which, together with the mode,
pump determines how long the selected function is active.
– a float switch installed on the inlet side of the Range: 0 to 15,000 seconds.
pump.
• "Accumulated flow" T input
T input>>T1
T1 ++T2
T2 T input < T1
T input < T1++ T2
T2

When this function is selected, you can register the


accumulated flow. This requires the use of a Digital input
T input T input
flowmeter which can give a feedback signal as a
pulse per defined flow of water. Mode A
See "Pulse flowmeter setup" on page 79. T1 T2 T1

• "Predefined setpoint digit 1" (applies only to digital

TM06 4949 3415


Mode B
input 2) T1 T2 T1 T2
When digital inputs are set to a predefined setpoint,
the pump operates according to a setpoint based on Mode C
the combination of the activated digital inputs. T1 T2 T1 T2

See "Predefined setpoints" on page 77. Fig. 57 Duration timer function of digital inputs
The priority of the selected functions in relation to each
other appears from section Priority of settings on page Factory setting
89. See section 13. Factory settings of E-pumps.
A stop command always has the highest priority. Motors from 15-22 kW, 2-pole and 11 - 18.5 kW,
Activation delay 4-pole
You can set the digital input of the pump can be set to
Pump variant Activation delay different functions. Select one of the following
TPE3, TPE3 D - functions:
TPE2, TPE 2 D ●
• "Min." (minimum curve)
2.2 - 11 kW, 2-pole

3 - 7.5 kW, 4-pole • "Max." (maximum curve).
TPE Series 1000
15-22 kW, 2-pole You activate the selected function by closing the
-
11 - 18.5 kW, 4-pole
contact between terminals 1 and 9.
Select the activation delay, T1. "Min.":
It is the time between the digital signal and the When the input is activated, the pump operates
activation of the selected function. according to the minimum curve.
Range: 0 to 6000 seconds. "Max.":
When the input is activated, the pump operates
according to the maximum curve.

70
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Digital inputs/outputs" Possible functions, digital input or output 4

User interfaces for TPE pumps


"Digital "Function if output"
Pump variant "Function if input"
inputs/outputs" See details in section "Signal
See details in section "Digital
relays 1 and 2" ("Relay
TPE3, TPE3 D ● inputs" on page 69
outputs") on page 72
TPE2, TPE2 D ●
• "Not active"
2.2 - 11 kW, 2-pole • "External stop" • "Not active"

3 - 7.5 kW, 4-pole • "Min." • "Ready"
TPE Series 1000
15-22 kW, 2-pole • "Max." • "Alarm"
-
11 - 18.5 kW, 4-pole • "User-defined speed" • "Operation"
• "External fault" • "Pump running"
• "Alarm resetting" • "Warning"
Function Terminals* • "Dry running" • "Limit 1 exceeded"
"Digital input/output 3, setup" 10 and 16 • "Accumulated flow" • "Limit 2 exceeded"
"Digital input/output 4, setup" 11 and 18 • "Predefined setpoint 3"

* See Connection terminals, advanced functional module, FM 300 on Activation delay


page 115.
Pump variant Activation delay
You can select if the interface must be used as input or TPE3, TPE3 D -
output. The output is an open collector and you can TPE2, TPE 2 D ●
connect it to for example an external relay or controller 2.2 - 11 kW, 2-pole

such as a PLC. TPE Series 1000
3 - 7.5 kW, 4-pole
15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole
+ 24V
Select the activation delay, T1.
It is the time between the digital signal and the
TM06 4463 2315

DO 3/4 activation of the selected function.


External
controller Range: 0 to 6000 seconds.
Duration timer mode
Select the mode. See fig. 59.
Fig. 58 Example of configurable digital inputs or outputs
• "Not active"
To set a digital input or output, make the settings • active with interrupt, mode A
below. • active without interrupt, mode B
Mode • active with after-run, mode C.
You can set the digital input or output 3 and 4 to act as Select the duration time, T2.
digital input or digital output: It is the time which, together with the mode,
• "Digital input" determines how long the selected function is active.
• "Digital output". Range: 0 to 15,000 seconds.
Function T input > >T1
T input T1 + T2
+ T2 T input < T1
T input < T1++T2
T2
You can set the digital input or output 3 and 4 to the
functions mentioned below. Digital input
T input T input
Possible functions, digital input or output 3
Mode A
"Function if output"
"Function if input" T1 T2 T1
See details in section "Signal
See details in section "Digital
relays 1 and 2" ("Relay
TM06 4949 3415

inputs" on page 69 Mode B


outputs") on page 72
T1 T2 T1 T2
• "Not active"
• "External stop" • "Not active"
• "Min." • "Ready" Mode C
• "Max." • "Alarm" T1 T2 T1 T2
• "User-defined speed" • "Operation"
• "External fault" • "Pump running" Fig. 59 Duration timer function of digital inputs
• "Alarm resetting" • "Warning"
• "Dry running" • "Limit 1 exceeded" Factory setting
• "Accumulated flow" • "Limit 2 exceeded"
• "Predefined setpoint 2" See section 13. Factory settings of E-pumps.

71
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"Signal relays 1 and 2" ("Relay outputs") "Analog output"


User interfaces for TPE pumps

"Relay outputs" Pump variant "Analog output"


Pump variant Signal Signal TPE3, TPE3 D ●
relay 1 relay 2 TPE2, TPE2 D ●
TPE3, TPE3 D ● ● 2.2 - 11 kW, 2-pole

3 - 7.5 kW, 4-pole
TPE2, TPE2 D ● ● TPE Series 1000
15-22 kW, 2-pole
2.2 kW, 2-pole ● ● -
11 - 18.5 kW, 4-pole
3 - 7.5 kW, 2-pole
● ●
TPE Series 1000 3 - 7.5 kW, 4-pole
11-22 kW, 2-pole Function Terminals*
● ●
11 - 18.5 kW, 4-pole "Analog output" 12

* See Connection terminals, advanced functional module, FM 300 on


Function Terminals* page 115.
"Relay output 1" NC, C1, NO
"Relay output 2" NC, C2, NO The analog output enables the transfer of certain
operating data to external control systems.
* See Connection terminals, advanced functional module, FM 300 on
page 115. To set the analog output, make the settings below.
The pump incorporates two signal relays for "Output signal"
potential-free signalling. For further information, see • "0-10 V"
Indicator lights and signal relays on page 91. • "0-20 mA"
Function • "4-20 mA".
You can configure the signal relays to be activated by "Function of analog output"
one of the following incidents:
• "Actual speed"
• "Not active"
• "Ready" "Actual speed"
Signal range [%]
The pump can be running or is ready to run and no [V, mA]
alarms are present. 0 100 200
"0-10 V" 0V 5V 10 V
• "Alarm"
"0-20 mA" 0 mA 10 mA 20 mA
There is an active alarm and the pump is stopped.
"4-20 mA" 4 mA 12 mA 20 mA
• "Operating" ("Operation")
"Operating" equals "Running" but the pump is still in The reading is a percentage of nominal speed.
operation when it has been stopped due to a • "Actual value"
warning.
Signal range "Actual value"
• "Running" ("Pump running") [V, mA] Sensormin Sensormax
• "Warning"
"0-10 V" 0V 10 V
There is an active warning.
"0-20 mA" 0 mA 20 mA
• "Limit 1 exceeded"* "4-20 mA" 4 mA 20 mA
When the "Limit 1 exceeded" function is activated,
the signal relay is activated. See "Limit-exceeded The reading is a percentage of the range between
function" on page 78. sensormin and sensormax.
• "Limit 2 exceeded"* • "Resulting setpoint"
When the "Limit 2 exceeded" function is activated, "Resulting setpoint"
the signal relay is activated. See "Limit-exceeded Signal range [%]
[V, mA]
function" on page 78. 0 100
• "Relubricate" "0-10 V" 0V 10 V
• "External fan control" ("Control of external fan") "0-20 mA" 0 mA 20 mA
When you select "External fan control", the relay is "4-20 mA" 4 mA 20 mA
activated if the internal temperature of the motor The reading is a percentage of the external setpoint
electronics reach a preset limit value. range.
* This function is only available for TPE3, TPE2 and TPE Series
1000 pumps with motor sizes from 2.2 to 11 kW, 2-pole and 3 - 7.5
kW, 4-pole.

Factory setting
See section 13. Factory settings of E-pumps.

72
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
• "Motor load" "Controller" ("Controller settings")

User interfaces for TPE pumps


"Motor load" Pump variant Controller settings
Signal range [%]
[V, mA] TPE3, TPE3 D ●
0 100 200 TPE2, TPE2 D ●
"0-10 V" 0V 5V 10 V 2.2 - 11 kW, 2-pole

"0-20 mA" 0 mA 10 mA 20 mA 3 - 7.5 kW, 4-pole
TPE Series 1000
"4-20 mA" 4 mA 12 mA 20 mA 15-22 kW, 2-pole

11 - 18.5 kW, 4-pole
The reading is a percentage of the range between 0
and 200 % of the maximum permissible load at the The pumps have a factory default setting of gain, Kp,
actual speed. and integral time, Ti.
• "Motor current" However, if the factory setting is not the optimum
setting, you can change the gain and the integral time:
"Motor current" • Set the gain within the range from 0.1 to 20.
Signal range [%]
[V, mA] • Set the integral time within the range from 0.1 to
0 100
3600 s.
0-10 V 0V 10 V If you select 3600 s, the controller functions as a P
0-20 mA 0 mA 20 mA
controller.
4-20 mA 4 mA 20 mA
Furthermore, you can set the controller to inverse
The reading is a percentage of the range between 0 control. This means that if the setpoint is increased,
and 200 % of the rated current. the speed is reduced. In the case of inverse control,
• "Limit 1 exceeded" and "Limit 2 exceeded" set the gain within the range from -0.1 to -20.
"Limit-exceed function" Guidelines for setting of PI controller
Signal range
[V, mA] Output not active Output active The tables below show the recommended controller
"0-10 V" 0V 10 V settings:
"0-20 mA" 0 mA 20 mA
Differential-pressure control Kp Ti
"4-20 mA" 4 mA 20 mA

The "Limit-exceeded function" is typically used for


monitoring of secondary parameters in the system. If
the limit is exceeded, an output, warning or alarm is
activated. p
0.5 0.5
• "Flow rate"
p

"Flow rate"
Signal range [%] p p
[V, mA]
0 100 200
"0-10 V" 0V 5V 10 V L1
"0-20 mA" 0 mA 10 mA 20 mA
ǻS
"4-20 mA" 4 mA 12 mA 20 mA
L1 < 5 m: 0.5
The reading is a percentage of the range between 0 0.5 L1 > 5 m: 3
and 200 % of the nominal flow. L1 L1 > 10 m: 5

Factory setting
ǻS
See section 13. Factory settings of E-pumps.

L1: Distance in metres between pump and sensor.

73
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Rules of thumb
User interfaces for TPE pumps

Kp
Temperature control Ti If the controller is too slow-reacting, increase the gain.
Heating Cooling
system 1) system 2) If the controller is hunting or unstable, dampen the
system by reducing the gain or increasing the integral
time.
0.5 -0.5 10 + 5L2 Factory setting
t
See section 13. Factory settings of E-pumps.
L2

L2
"Operating range"
t 0.5 -0.5 30 + 5L2 Pump variant "Operating range"
TPE3, TPE3 D ●
TPE2, TPE2 D ●
1) 2.2 - 11 kW, 2-pole
In heating systems, an increase in pump performance results in a ●
3 - 7.5 kW, 4-pole
rise in temperature at the sensor. TPE Series 1000
2) 15-22 kW, 2-pole
In cooling systems, an increase in pump performance results in a ●
11 - 18.5 kW, 4-pole
drop in temperature at the sensor.

L2: Distance in metres between heat exchanger and Set the operating range as follows:
sensor. • Set the minimum speed within the range from fixed
minimum speed to user-set maximum speed.
Differential-temperature control Kp Ti
• Set the maximum speed within the range from
user-set minimum speed to fixed maximum speed.
The range between the user-set minimum and
t
maximum speeds is the operating range.
L2 Note: Speeds below 25 % may result in noise from the
-0.5 10 + 5L2 shaft seal.
t
100 % Fixed maximum speed
t

t
L2 67 % User-set maximum speed

L2: Distance in metres between heat exchanger and


sensor.
Operating range
Flow control Kp Ti

TM00 6785 5095


0.5 0.5
Q 24 % User-set minimum speed

13 % Fixed minimum speed


Constant-pressure control Kp Ti
0%

Fig. 60 Example of minimum and maximum settings


0.5 0.5
Factory setting
p
See section 13. Factory settings of E-pumps.

p 0.1 0.5

Level control Kp Ti
L

-2.5 100

2.5 100

74
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"External setpoint influence" Example with constant pressure with linear

User interfaces for TPE pumps


influence
"External setpoint
Pump variant
influence"
Actual setpoint: actual input signal x (setpoint - sensor
min.) + sensor min.
TPE3, TPE3 D ●
TPE2, TPE2 D ● At a lower sensor value of 0 bar, a setpoint of 2 bar
2.2 - 11 kW, 2-pole and an external setpoint of 60 %, the actual setpoint is

3 - 7.5 kW, 4-pole 0.60 x (2 - 0) + 0 = 1.2 bar.
TPE Series 1000
15-22 kW, 2-pole

11 - 18.5 kW, 4-pole [bar]

TPE2, TPE3 pumps and TPE Series 1000 2.2 - 11 Sensor max.
kW, 2-pole and 3 - 7.5 kW, 4-pole pumps
You can influence the setpoint by an external signal, "Setpoint" 2 100
either via one of the analog inputs or, if an advanced
functional module is fitted, via one of the Pt100/1000 Actual 1.2
setpoint
inputs.
Note: Before you can enable the "External setpoint Sensor min. 0 0
Actual 100 % External
function", set one of the analog inputs or Pt100/1000 0

TM06 4165 1615


0.5 input 3.5 V setpoint
inputs to "Setpoint influence". 0 signal, 5V signal
60 %
See "Analog inputs" on page 67 and "Pt100/1000 0 10 V
0 20 mA
inputs" on page 69. 4 20 mA
-50 204 C
If more than one input has been set to "Setpoint
influence", the function selects the analog input with Fig. 61 Example of setpoint influence with sensor
the lowest number, for example "Analog input 2", and feedback
ignores the other inputs, for example "Analog input 3"
Example with constant curve with linear influence
or "Pt100/1000 input 1".
Actual setpoint: actual input signal x (setpoint -
Motors from 15-22 kW, 2-pole and 11 - 18.5 kW, user-set minimum speed) + user-set minimum speed.
4-pole
At a user-set minimum speed of 25 %, a setpoint of 85
You can set the input for external setpoint signal to % and an external setpoint of 60 %, the actual setpoint
different signal types. Select one of the following is 0.60 x (85 - 25) + 25 = 61 %. See fig. 62.
types: In some cases, the maximum curve is limited to a
• "0-10 V" lower speed. See fig. 62.
• "0-20 mA"
Speed [%]
• "4-20 mA"
• "Not active". Fixed maximum
100
If you select one of the signal types, the actual setpoint "Setpoint" 85
speed
is influenced by the signal connected to the external
setpoint input. Actual 61
setpoint

User-set min. 25
speed

0
0 Actual 100 % External
TM06 4525 2515

0.5 input 3.5 V setpoint


0 signal, 5V signal
0 60 % 10 V
0 20 mA
4 20 mA
-50 204 C

Fig. 62 Example of setpoint influence with constant curve

Factory setting
See section 13. Factory settings of E-pumps.

75
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"Setpoint influence" – "Linear with Stop"


User interfaces for TPE pumps

In the input signal range from 20 to 100 %, the


"External setpoint setpoint is influenced linearly.
Pump variant
influence"
If the input signal is below 10 %, the pump
TPE3, TPE3 D ●
changes to operating mode "Stop".
TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole
If the input signal is increased above 15 %, the
● operating mode is changed back to "Normal". See
3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole

fig. 64.
11 - 18.5 kW, 4-pole
"Setpoint influence" [%]
The table below gives an overview of the types of
setpoint influence and the availability depending on
pump type. 100

TPE Series
1000

11 - 18.5 kW, 4-pole


2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole

15-22 kW, 2-pole


Type of setpoint influence

0
0 20 100 % External
3.5 V input
TPE3

TPE2

0.5
0 5V
"Not active" ● ● ● ● 0 10 V
0 20 mA
"Linear function" ● ● ● ● 4 20 mA
"Linear with Stop" ● ● ● - -50 204 C
"Influence table" ● ● ● -

TM06 4167 1615


You can select these functions: "Normal"
• "Not active"
When set to "Not active", the setpoint is not "Stop"
influenced from any external function.
Fig. 64 "Linear with Stop"
• "Linear function"
The setpoint is influenced linearly from 0 to 100 %. • "Influence table"
See fig. 63. The setpoint is influenced by a curve made out of
two to eight points. There will be a straight line
"Setpoint influence" [%]
between the points and a horizontal line before the
first point and after the last point.
100
"Setpoint influence" [%]

100

0
0 100 % External
input
0.5 3.5 V
TM06 4166 1615

0 5V
0 10 V 0
0 20 mA 0 100 % External
4 20 mA 0.5 3.5 V input
TM06 4170 1615

-50 204 C 0 5V
0 10 V
Fig. 63 "Linear function" 0 20 mA
4 20 mA
-50 204 C

Fig. 65 "Influence table", example with five points

76
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Predefined setpoints" "Temperature influence"

User interfaces for TPE pumps


"Predefined "Temperature
Pump variant Pump variant
setpoints" influence"

TPE3, TPE3 D - TPE3, TPE3 D ●


TPE2, TPE2 D ● TPE2, TPE2 D -
2.2 - 11 kW, 2-pole 2.2 - 11 kW, 2-pole
● -
3 - 7.5 kW, 4-pole 3 - 7.5 kW, 4-pole
TPE Series 1000 TPE Series 1000
15-22 kW, 2-pole 15-22 kW, 2-pole
- -
11 - 18.5 kW, 4-pole 11 - 18.5 kW, 4-pole

You can set and activate seven predefined setpoints When this function is enabled in proportional- or
by combining the input signals to digital inputs 2, 3 and constant-pressure control mode, the setpoint for head
4 as shown in the table below. is reduced according to the liquid temperature.
Set the digital inputs 2, 3 and 4 to "Predefined You can set the temperature influence to function at
setpoints" if all seven predefined setpoints are to be liquid temperatures below 80 or 50 °C. These
used. You can also set one or two of the digital inputs temperature limits are called Tmax. The setpoint is
to "Predefined setpoints" but this will limit the number reduced in relation to the head set which is equal to
of predefined setpoints available. 100 % according to the characteristics below.

"Digital inputs" H H
"Setpoint"
2 3 4
0 0 0 Normal setpoint or stop
1 0 0 Predefined setpoint 1 100 %
0 1 0 Predefined setpoint 2 Hactual
H actual
1 1 0 Predefined setpoint 3
0 0 1 Predefined setpoint 4

TM05 7911 1613


1 0 1 Predefined setpoint 5 30 %
0 1 1 Predefined setpoint 6
1 1 1 Predefined setpoint 7 20 50 80 T [°C] Q
0: Open contact Tactual
Tactual
1: Closed contact
Fig. 67 Temperature influence
Example
In the above example, Tmax. which is equal to 80 °C
Figure 66 shows how you can use the digital inputs to
has been selected. The actual liquid temperature,
set seven predefined setpoints. Digital input 2 is open
Tactual, causes the setpoint for head to be reduced
and digital inputs 3 and 4 are closed. If you compare
from 100 % to H actual.
with the table above, you can see that "Predefined
setpoint 6" is activated. The temperature influence function requires the
following:
Digital input 4 Setpoint 7 • proportional-pressure or constant-pressure control
Digital input 3 7 6 Setpoint 6 mode
Digital input 2 5
Setpoint 5 • pump installed in flow pipe
4
Actual setpoint
Setpoint 4 • system with flow-pipe temperature control.
3
Setpoint 3 Temperature influence is suitable for the following
2
Setpoint 2
systems:
TM06 4269 1815

1
0 Setpoint 1
• Systems with variable flows, for example two-pipe
heating systems, in which the enabling of the
Normal
setpoint temperature influence function will ensure a further
Stop reduction of the pump performance in periods with
Fig. 66 Principle sketch showing how predefined setpoints small heating demands and consequently a reduced
function flow-pipe temperature.
If all digital inputs are open, the pump either stops or • Systems with almost constant flows, for example
runs at the normal setpoint. Set the desired action with one-pipe heating systems and underfloor heating
Grundfos GO or with the advanced control panel. systems, in which variable heating demands cannot
be registered as changes in the head as it is the
Factory setting case with two-pipe heating systems. In such
See section 13. Factory settings of E-pumps. systems, you can only adjust the pump performance
by enabling the temperature influence function.

77
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Selection of the maximum temperature Action


User interfaces for TPE pumps

In systems with a dimensioned flow-pipe temperature If the value exceeds a limit, you can define an action.
of: You can select the following actions:
• up to and including 55 °C, select Tmax. equal to 50 • "No action"
°C The pump remains in its current state. Use this
• above 55 °C, select Tmax. equal to 80 °C. setting if you only want to have a relay output when
Note: You cannot use the temperature function in the limit is reached. See "Signal relays 1 and 2"
air-conditioning and cooling systems. ("Relay outputs") on page 72.
• "Warning/alarm"
Factory setting There is a warning.
See section 13. Factory settings of E-pumps. • "Stop"
The pump stops.
"Limit-exceeded function"
• "Min."
"Limit-exceeded The pump reduces speed to minimum.
Pump variant
function" • "Max."
TPE3, TPE3 D ● The pump increases speed to maximum.
TPE2, TPE2 D ●
• "User-defined speed"
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
● The pump runs at a speed set by the user.
TPE Series 1000
15-22 kW, 2-pole "Detection delay"
-
11 - 18.5 kW, 4-pole
You can set a detection delay which ensures that the
This function can monitor a measured parameter or monitored parameter stays above or below a set limit
one of the internal values such as speed, motor load or in a set time before the function is activated.
motor current. If a set limit is reached, a selected
action can take place. You can set two limit-exceeded "Resetting delay"
functions meaning that you can monitor two The resetting delay is the time from which the
parameters or two limits of the same parameter measured parameter differs from the set limit including
simultaneously. the set hysteresis band and until the function is reset.
The function requires setting of the following: Example
Measured The function is to monitor the outlet pressure of a
Here you set the measured parameter to be monitored. pump. If the pressure is below 5 bar for more than 5
seconds, a warning must be given. If the outlet
"Limit"
pressure is above 7 bar for more than 8 seconds, you
Here you set the limit which activates the function. must reset the warning.
"Hysteresis band"
1
Here you set the hysteresis band.
"Limit exceeded when"
3
Here you can set if you want the function to be 2

activated when the selected parameter exceeds or


drops below the set limit.
• "Above limit" 4 4 TM06 4603 2515

The function is activated if the measured parameter A


exceeds the set limit.
Time [s]
• "Below limit" 5 6

The function is activated if the measured parameter Fig. 68 Limit exceeded, example
drops below the set limit.
Pos. Setting parameter Setting
1 Measured Outlet pressure
2 "Limit" 5 bar
3 "Hysteresis band" 2 bar
4 "Limit exceeded when" Below limit
5 "Detection delay" 5 seconds
6 "Resetting delay" 8 seconds
A Limit-exceeded function active -
- Action Warning

Factory setting
See section 13. Factory settings of E-pumps.

78
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Special functions "Standstill heating"

User interfaces for TPE pumps


"Pulse flowmeter setup" Pump variant "Standstill heating"
TPE3, TPE3 D ●
"Pulse flowmeter
Pump variant TPE2, TPE2 D ●
setup"
2.2 - 11 kW, 2-pole
TPE3, TPE3 D ● ●
3 - 7.5 kW, 4-pole
TPE2, TPE2 D ● TPE Series 1000
15-22 kW, 2-pole

2.2 - 11 kW, 2-pole 11 - 18.5 kW, 4-pole

3 - 7.5 kW, 4-pole
TPE Series 1000 You can use this function to avoid condensation in
15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole humid environments. When you set the function to
You can connect an external pulse flowmeter to one of "Active" and the pump is in operating mode "Stop", a
the digital inputs in order to register the actual and low AC voltage will be applied to the motor windings.
accumulated flows. Based on this, you can also The voltage is not high enough to make the motor
calculate the specific energy. rotate but ensures that sufficient heat is generated to
avoid condensation in the motor including the
To enable a pulse flowmeter, set one of the digital
electronic parts in the drive.
inputs to "Accumulated flow" and set the pumped
volume per pulse. See "Digital inputs" on page 69. Note: Remember to remove the drain plugs and fit a
cover over the motors.
"Ramps"
Factory setting
Pump variant "Ramps" See section 13. Factory settings of E-pumps.
TPE3, TPE3 D ●
TPE2, TPE2 D ●
"Motor bearing monitoring"
2.2 - 11 kW, 2-pole
● "Motor bearing
3 - 7.5 kW, 4-pole Pump variant
TPE Series 1000 monitoring"
15-22 kW, 2-pole
- TPE3, TPE3 D ●
11 - 18.5 kW, 4-pole
TPE2, TPE2 D ●
The ramps determine how quickly the motor can 2.2 - 11 kW, 2-pole

accelerate and decelerate, during start-stop or setpoint 3 - 7.5 kW, 4-pole
TPE Series 1000
changes. 15-22 kW, 2-pole

11 - 18.5 kW, 4-pole
You can set the following:
• acceleration time, 0.1 to 300 seconds You can set the motor bearing monitoring function to
these values:
• deceleration time, 0.1 to 300 seconds.
• "Active"
The times apply to the acceleration from 0 rpm to fixed
maximum speed and the deceleration from fixed • "Not active"
maximum speed to 0 rpm. When the function is set to "Active", a counter in the
At short deceleration times, the deceleration of the controller will start counting the mileage of the
motor may depend on load and inertia as there is no bearings.
possibility of actively braking the motor. The counter continues counting even if the function is
If the power supply is switched off, the deceleration of changed to "Not active", but a warning is not given
the motor only depends on load and inertia. when it is time for replacement or relubrication.
When the function is changed to "Active again", the
Speed
accumulated mileage is again used to calculate the
Fixed replacement or relubrication time.
maximum

User-set Factory setting


maximum See section 13. Factory settings of E-pumps.
User-set
minimum
Time
0
TM03 9439 0908

Fixed initial ramp Fixed final ramp

User-set ramp-up User-set


ramp-down

Fig. 69 Ramp-up and ramp-down

Factory setting
See section 13. Factory settings of E-pumps.

79
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"Service" "Bearings relubricated" ("Motor bearing


User interfaces for TPE pumps

maintenance")
Pump variant "Service"
The following applies only for 11 kW motors.
TPE3, TPE3 D ●
When the bearing monitoring function is active, the
TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole
controller gives a warning when the motor bearings are
● due to be relubricated.
3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole When you have relubricated the motor bearings, press
-
11 - 18.5 kW, 4-pole
[Bearings relubricated].
"Motor bearing monitoring" must be activated in order The factory-set interval between relubrications is
for the motor to indicate that bearings must be stated on the bearing nameplate which is placed on
replaced or relubricated. See "Motor bearing the motor. The relubrication interval can be changed
monitoring" on page 79. by a Grundfos service technician.
For motors of 7.5 kW and below, it is not possible to It is possible to relubricate the bearings five times
relubricate the bearings. according to the preset interval. When the preset
Bearings on motors of 11 kW and above can be interval has been reached after the fifth relubrication, a
relubricated. warning will be given to replace the bearings.
"Time until next service" ("Motor bearing service")
Communication
This display shows when to replace or relubricate the
motor bearings. The controller monitors the operating "Number" ("Pump number")
pattern of the motor and calculates the period between
Pump variant "Pump number"
bearing replacements or relubrications.
TPE3, TPE3 D ●
Displayable values: TPE2, TPE2 D ●
• "in 2 years" 2.2 - 11 kW, 2-pole

3 - 7.5 kW, 4-pole
• "in 1 year" TPE Series 1000
15-22 kW, 2-pole

• "in 6 months" 11 - 18.5 kW, 4-pole
• "in 3 months" You can allocate a unique number to the pump. This
• "in 1 month" makes it possible to distinguish between pumps in
• "in 1 week" connection with bus communication.
• "Now" Factory setting
"Bearing replacements" See section 13. Factory settings of E-pumps.
This display shows the number of bearing "Radio communication" ("Enable/disable radio
replacements that have been done during the lifetime comm.")
of the motor.
"Radio
"Bearings replaced" ("Motor bearing Pump variant
communication"
maintenance") TPE3, TPE3 D ●
When the bearing monitoring function is active, the TPE2, TPE2 D ●
controller gives a warning when the motor bearings are 2.2 - 11 kW, 2-pole

3 - 7.5 kW, 4-pole
to be replaced. TPE Series 1000
15-22 kW, 2-pole
-
When you have replaced the motor bearings, confirm 11 - 18.5 kW, 4-pole
this action by pressing [Bearings replaced].
You can set the radio communication to either enabled
"Bearing relubrications" or disabled. You can use this function in areas where
The following applies only for 11 kW motors. radio communication is not allowed.
This display shows the number of bearing IR communication remains active.
relubrications that have been done since the last Factory setting
bearing replacement.
See section 13. Factory settings of E-pumps.

80
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
General settings "Buttons on product" ("Enable/disable settings")

User interfaces for TPE pumps


"Language" "Buttons on
Pump variant
product"
Pump variant "Language" TPE3, TPE3 D ●
TPE3, TPE3 D ● TPE2, TPE2 D ●
TPE2, TPE2 D ● 2.2 - 11 kW, 2-pole

2.2 - 11 kW, 2-pole 3 - 7.5 kW, 4-pole
● TPE Series 1000
3 - 7.5 kW, 4-pole 15-22 kW, 2-pole
TPE Series 1000 ●
15-22 kW, 2-pole 11 - 18.5 kW, 4-pole

11 - 18.5 kW, 4-pole
In this display, you can disable the possibility of
This menu is only available in the advanced control making settings.
panel.
Grundfos GO
In this menu you can select the desired language. A
number of languages is available. If you set the buttons to "Not active", the buttons on the
standard control panel are disabled. If you set the
"Date and time" buttons to "Not active" on pumps with an advanced
control panel, see below.
Pump variant "Date and time"
TPE3, TPE3 D ● Advanced control panel
TPE2, TPE2 D ● If you have disabled the settings, you can still use the
2.2 - 11 kW, 2-pole buttons to navigate through the menus but you cannot

3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole
make changes in the "Settings" menu.
-
11 - 18.5 kW, 4-pole When you have disabled the possibility to make
You can set date and time as well as how they are to settings, the symbol appears in the display.
be shown in the display: To unlock the pump and allow settings, press and
• "Select date format" simultaneously for at least 5 seconds.
"YYYY-MM-DD" Standard control panel
"DD-MM-YYYY" The button always remains active but you can only
"MM-DD-YYYY" unlock all other buttons on the pump with Grundfos
• "Select time format": GO.
"HH:MM 24-hour clock"
"HH:MM am/pm 12-hour clock". "Delete history"
• "Set date" Pump variant "Delete history"
• "Set time".. TPE3, TPE3 D ●
TPE2, TPE2 D ●
"Unit configuration" ("Units")
2.2 - 11 kW, 2-pole

3 - 7.5 kW, 4-pole
Pump variant "Unit configuration" TPE Series 1000
15-22 kW, 2-pole
-
TPE3, TPE3 D ● 11 - 18.5 kW, 4-pole
TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole
This menu is only available in the advanced control
● panel.
3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole In this menu, you can delete the following historic data:
-
11 - 18.5 kW, 4-pole
• "Delete work log."
In this menu you can select between SI and US units. • "Delete heat energy data".
The setting can be made generally for all parameters
• "Delete energy consumption".
or customised for each parameter.
Factory setting
See section 13. Factory settings of E-pumps.

81
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"Define Home display" "Recall settings" ("Recall stored settings")


User interfaces for TPE pumps

"Define Home Pump variant "Recall settings"


Pump variant
display"
TPE3, TPE3 D ●
TPE3, TPE3 D ● TPE2, TPE2 D ●
TPE2, TPE2 D ● 2.2 - 11 kW, 2-pole

2.2 - 11 kW, 2-pole 3 - 7.5 kW, 4-pole
● TPE Series 1000
3 - 7.5 kW, 4-pole 15-22 kW, 2-pole
TPE Series 1000 ●
15-22 kW, 2-pole 11 - 18.5 kW, 4-pole
-
11 - 18.5 kW, 4-pole
Grundfos GO
This menu is only available in the advanced control
In this menu, you can recall stored settings from a
panel.
number of previously stored settings that the pump
In this menu, you can set the "Home" display to show then uses.
up to four user-set parameters.
Advanced control panel
"Display settings"
In this menu, you can recall the last stored settings
Pump variant "Display settings" that the pump then uses.
TPE3, TPE3 D ● "Undo"
TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole Pump variant "Undo"

3 - 7.5 kW, 4-pole
TPE Series 1000 TPE3, TPE3 D ●
15-22 kW, 2-pole
- TPE2, TPE2 D ●
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole

This menu is only available in the advanced control 3 - 7.5 kW, 4-pole
TPE Series 1000
panel. 15-22 kW, 2-pole

11 - 18.5 kW, 4-pole
In this menu you can adjust the display brightness and
set whether or not the display is to turn off if no buttons This menu is only available in Grundfos GO.
have been activated for a period of time. In this display, you can undo all settings that have
"Store settings" ("Store actual settings") been made with Grundfos GO in the current
communication session. You cannot undo a "Recall
Pump variant "Store settings" stored settings" action.
TPE3, TPE3 D ● "Pump name"
TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole Pump variant "Pump name"

3 - 7.5 kW, 4-pole
TPE Series 1000 TPE3, TPE3 D ●
15-22 kW, 2-pole
● TPE2, TPE2 D ●
11 - 18.5 kW, 4-pole
2.2 - 11 kW, 2-pole

Grundfos GO 3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole
In this menu, you can store the actual settings for later 11 - 18.5 kW, 4-pole
-
use in the same pump or in other pumps of the same
type. This menu is only available in Grundfos GO.
In this display, you can give the pump a name. In this
Advanced control panel
way, you can easily identify the pump when connecting
In this menu, you can store the actual settings for later with Grundfos GO.
use in the same pump.
Factory setting
See section 13. Factory settings of E-pumps.

82
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Connection code" "Run start-up guide"

User interfaces for TPE pumps


Pump variant "Connection code" Pump variant "Run start-up guide"
TPE3, TPE3 D ● TPE3, TPE3 D ●
TPE2, TPE2 D ● TPE2, TPE2 D ●
2.2 - 11 kW, 2-pole 2.2 - 11 kW, 2-pole
● ●
3 - 7.5 kW, 4-pole 3 - 7.5 kW, 4-pole
TPE Series 1000 TPE Series 1000
15-22 kW, 2-pole 15-22 kW, 2-pole
- -
11 - 18.5 kW, 4-pole 11 - 18.5 kW, 4-pole

This menu is only available in Grundfos GO. This menu is only available in the advanced control
You can set a connection code to avoid having to press panel.
the connection button each time and to restrict remote The startup guide automatically starts when you start
access to the product. the pump for the first time.
Setting the code in the product using Grundfos GO You can always run the startup guide later via this
menu.
1. Connect Grundfos GO to the product.
The startup guide guides you through the general
2. In the product dashboard, select "Settings".
settings of the pump.
3. Choose "Connection code".
• "Language". See "Language" on page 81.
4. Enter the wanted code and press [OK].
• "Select date format".*
The code must be a character string, ASCII. You
See "Date and time" on page 81.
can always modify the code. The old code is not
needed. • "Set date".*
See "Date and time" on page 81.
Setting the code in Grundfos GO • "Select time format".*
You can set a default connection code in Grundfos GO See "Date and time" on page 81.
so that it automatically attempts to connect to the • "Set time".*
selected product via this code. See "Date and time" on page 81.
When you select a product with the same connection • "Setting of pump"
code in Grundfos GO, Grundfos GO automatically
– "Go to Home"
connects to the product and you do not have to press
the connection button on the module. – "Run with Constant curve"/"Run with Constant
pressure".
Set the default code in Grundfos GO in this way:
See "Control mode" on page 59
1. In the main menu, under "General", select
– "Go to Assisted pump setup".
"Settings".
See "Assisted pump setup" on page 84.
2. Choose "Remote".
– "Return to factory settings".
3. Enter the connection code in the field "Preset * Applies only for pumps with advanced functional module, FM 300.
connection code". The field now says "Connection For further information, see Identification of functional module on
code set". page 120.

You can always modify the default connection code by "Alarm log"
pressing [Delete] and entering a new one.
Pump variant "Alarm log"
If Grundfos GO fails to connect and ask you to press
TPE3, TPE3 D ●
the connection button on the product, it means that the
TPE2, TPE2 D ●
product has no connection code or has a different 2.2 - 11 kW, 2-pole
connection code. In this case, you can only establish ●
3 - 7.5 kW, 4-pole
TPE Series 1000
connection via the connection button. 15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole
After setting a connection code, you must switch off
the product until the light in Grundfos Eye turns off This menu contains a list of logged alarms from the
before you can use the new connection code. product. The log shows the name of the alarm, when
the alarm occurred and when it was reset.
Factory setting
See section 13. Factory settings of E-pumps.

83
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

"Warning log" Grundfos GO


User interfaces for TPE pumps

1. Open the "Assist" menu.


Pump variant "Warning log"
TPE3, TPE3 D ●
2. Select "Assisted pump setup".
TPE2, TPE2 D ● 3. Select the control mode "Constant pressure".
2.2 - 11 kW, 2-pole 4. Read the description of this control mode.

3 - 7.5 kW, 4-pole
TPE Series 1000 5. Select which analog input to use as sensor input.
15-22 kW, 2-pole
-
11 - 18.5 kW, 4-pole 6. Select sensor function according to where the
This menu contains a list of logged warnings from the sensor is installed in the system. See fig. 55.
product. The log shows the name of the warning, when 7. Select electrical input signal according to the
the warning occurred and when it was reset. sensor specifications.
8. Select measuring unit according to the sensor
"Assist" specifications.
9. Set the minimum and maximum sensor values
Pump variant "Assist"
according to the sensor specifications.
TPE3, TPE3 D ●
TPE2, TPE2 D ● 10.Set the desired setpoint.
2.2 - 11 kW, 2-pole

11.Set the controller settings Kp and Ti. See the
3 - 7.5 kW, 4-pole recommendations in section "Controller"
TPE Series 1000
15-22 kW, 2-pole
11 - 18.5 kW, 4-pole
- ("Controller settings") on page 73.
12.Type the pump name.
The menu consist of functions which take you through
13.Check the summary of settings and confirm them.
the steps needed to set the pump.
Advanced control panel
"Assisted pump setup"
1. Open the "Assist" menu.
"Assisted pump 2. Select "Assisted pump setup".
Pump variant
setup"
TPE3, TPE3 D ●
3. Select the control mode "Const. pressure".
TPE2, TPE2 D ● 4. Select which analog input to be used as sensor
2.2 - 11 kW, 2-pole

input.
3 - 7.5 kW, 4-pole
TPE Series 1000 5. Select the measured parameter to be controlled.
15-22 kW, 2-pole
- See fig. 55.
11 - 18.5 kW, 4-pole
6. Select measuring unit according to the sensor
The menu guides you through the following:
specifications.
Setting of pump 7. Set the minimum and maximum sensor values
• Selection of control mode. See page 59. according to the sensor specifications.
• Configuration of feedback sensors. 8. Select electrical input signal according to the
• Adjusting the setpoint. See page 58. sensor specifications.
• Controller settings. See page 73. 9. Set the setpoint.
• Summary of settings. 10.Set the controller settings Kp and Ti. See
Example of how to use the "Assisted pump setup" for recommendations in section "Controller"
setting up the pump to constant pressure: ("Controller settings") on page 73.
11.Check the summary of settings and confirm them by
pressing [OK].

84
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
"Setup, analog input" "Multipump setup" ("Setup of multi-pump system")

User interfaces for TPE pumps


"Setup, analog Pump variant "Multipump setup"
Pump variant
input"
TPE3, TPE3 D ●
TPE3, TPE3 D ● TPE2, TPE2 D ●
TPE2, TPE2 D ● 2.2 - 11 kW, 2-pole

2.2 - 11 kW, 2-pole 3 - 7.5 kW, 4-pole
● TPE Series 1000
3 - 7.5 kW, 4-pole 15-22 kW, 2-pole
TPE Series 1000 -
15-22 kW, 2-pole 11 - 18.5 kW, 4-pole
-
11 - 18.5 kW, 4-pole
The multipump function enables the control of two
This menu is only available in the advanced control pumps connected in parallel without the use of
panel. external controllers. The pumps in a multipump system
The menu guides you through the following: communicate with each other via the wireless GENIair
"Setup, analog input" connection or the wired GENI connection.
A multipump system is set via a selected pump, such
• Analog inputs 1 to 3. See page 67.
as the master pump which is the first selected pump.
• Pt100/1000 input 1 and 2. See page 69.
If two pumps in the system are configured with an
• Adjusting the setpoint. See page 58. outlet-pressure sensor, both pumps can function as
• Summary. master pumps and take over the master pump function
"Setting of date and time" if the other fails. This provides additional redundancy
in the multipump system.
"Setting of date and The multipump functions are described in the following
Pump variant
time"
sections.
TPE3, TPE3 D ●
TPE2, TPE2 D ● Alternating operation
2.2 - 11 kW, 2-pole Alternating operation functions as a duty-standby

3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole
operating mode and is possible with two pumps of
- same size and type connected in parallel. The main
11 - 18.5 kW, 4-pole
purpose of the function is to ensure an even amount of
This menu guides you through the following:
running hours and to ensure that the standby pump
• "Select date format". See "Date and time" on page takes over if the running pump stops due to an alarm.
81.
Each pump requires a non-return valve in series with
• "Set date". See "Date and time" on page 81. the pump.
• "Select time format". See "Date and time" on page You can choose between two alternating operation
81. modes:
• "Set time". See "Date and time" on page 81. • Alternating operation, time
Pump changeover to the other is based on time.
• Alternating operation, energy
Pump changeover to the other is based on energy
consumption.
If the duty pump fails, the other pump takes over
automatically.
Backup operation
Backup operation is possible with two pumps of same
size and type connected in parallel. Each pump
requires a non-return valve in series with the pump.
One pump is operating continuously. The backup
pump is operated for a short time each day to prevent
seizing up. If the duty pump stops due to a fault, the
backup pump starts automatically.

85
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Cascade operation Grundfos GO and wireless pump connection


User interfaces for TPE pumps

Cascade operation ensures that the pump 1. Power on both pumps.


performance is automatically adapted to the 2. Establish contact to one of the pumps with
consumption by switching pumps on or off. The system Grundfos GO.
thus runs as energy-efficiently as possible with a 3. Set the needed analog and digital inputs via
constant pressure and a limited number of pumps. Grundfos GO according to the connected
When a twin-head pump is running in equipment and the required functionality. See
constant-pressure control mode, the second pump "Assisted pump setup" on page 84.
head starts at 90 % and stops at 50 % performance. 4. Assign a pump name to the pump using Grundfos
All pumps in operation run at equal speed. Pump GO. See "Pump name" on page 82.
changeover is automatic and depends on energy, 5. Disconnect Grundfos GO from the pump.
operating hours and fault.
6. Establish contact to the other pump.
Pump system:
7. Set the needed analog and digital inputs via
• Twin-head pump. Grundfos GO according to the connected
• Two or four single-head pumps connected in equipment and the required functionality. See
parallel. "Assisted pump setup" on page 84.
The pumps must be of the same type and size. 8. Assign a pump name to the pump using Grundfos
Each pump requires a non-return valve in series GO. See "Pump name" on page 82.
with the pump.
9. Select the "Assist" menu and "Multipump setup".
Set the control mode to "Const. pressure" or "Const.
10.Select the desired multipump function. See
curve".
Alternating operation on page 85, Backup operation
This function is available with up to 4 motors installed on page 85 and Cascade operation on page 86.
in parallel. The motors must be of the same size
11.Press [>] to continue.
andthe pumps must be of the same model.
12.Set the time for pump changeover such as the time
• The performance is adjusted to the demand through
at which the alternation between the two pumps is
cutting pumps in or out and through parallel control
to take place. This step applies only if you have
of the pumps in operation.
selected "Alternating operation, time" and if the
• The controller maintains a constant pressure pumps are fitted with FM 300.
through continuous adjustment of the speed of the
13.Press [>] to continue.
pumps.
14.Select "Radio" as the communication method to be
• Pump changeover is automatic and depends on
used between the two pumps.
load, operating hours and fault detection.
15.Press [>] to continue.
• All pumps in operation run at the same speed.
16.Press "Select pump 2".
• The number of pumps in operation also depends on
the energy consumption of the pumps. If only one 17.Select the pump from the list.
pump is required, two pumps will run at a lower Use the [OK] or button to identify the pump.
speed if this results in a lower energy consumption. 18.Press [>] to continue.
• If several motors in the system have a sensor, they 19.Confirm the multipump setup by pressing [Send].
can all function as master and take over the master 20.Press [Finish] in the "Setup complete" dialog box.
function if the other fails. 21.Wait for the green indicator light in the middle of
Setting a multipump system Grundfos Eye to light up.
You can set a multipump system in the following ways: The multipump system has now been set.
• Grundfos GO and wireless pump connection
• Grundfos GO and wired pump connection
• Advanced control panel and wireless pump
connection
• Advanced control panel and wired pump
connection.
See step-by-step descriptions below.

86
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Grundfos GO and wired pump connection Advanced control panel and wireless pump

User interfaces for TPE pumps


1. Connect the two pumps with each other with a connection
3-core screened cable between the GENIbus 1. Power on both pumps.
terminals A, Y, B. 2. On both pumps, set the needed analog and digital
2. Power on both pumps. inputs according to the connected equipment and
3. Establish contact to one of the pumps with the required functionality. See "Assisted pump
Grundfos GO. setup" on page 84.
4. Set the needed analog and digital inputs via 3. Select the "Assist" menu on one of the pumps and
Grundfos GO according to the connected choose "Setup of multi-pump system".
equipment and the required functionality. See 4. Press [>] to continue.
"Assisted pump setup" on page 84. 5. Select "Wireless" as the communication method to
5. Assign a pump name to the pump using Grundfos be used between the two pumps.
GO. See "Pump name" on page 82. 6. Press [>] to continue.
6. Assign pump number 1 to the pump. See "Number" 7. Select the desired multipump function. See
("Pump number") on page 80. Alternating operation on page 85, Backup operation
7. Disconnect Grundfos GO from the pump. on page 85 and Cascade operation on page 86.
8. Establish contact to the other pump. 8. Press [>] three times to continue.
9. Set the needed analog and digital inputs via 9. Press [OK] to search for other pumps.
Grundfos GO according to the connected The green indicator light in the middle of Grundfos
equipment and the required functionality. See Eye flashes on the other pumps.
"Assisted pump setup" on page 84. 10.Press the connect button on the pump which is to
10.Assign a pump name to the pump using Grundfos be added to the multipump system.
GO. See "Pump name" on page 82. 11.Press [>] to continue.
11.Assign pump number 2 to the pump. See "Number" 12.Set the time for pump changeover such as the time
("Pump number") on page 80. at which the alternation between the two pumps is
12.Select the "Assist" menu and choose "Multipump to take place. This step applies only if you have
setup". selected "Alternating operation, time" and if the
13.Select the desired multipump function. See pumps are fitted with FM 300.
Alternating operation on page 85, Backup operation 13.Press [>] to continue.
on page 85 and Cascade operation on page 86. 14.Press [OK].
14.Press [>] to continue. The multipump function icons appear in the bottom
15.Set the time for pump changeover such as the time of the control panels.
at which the alternation between the two pumps is The multipump system has now been set.
to take place. This step applies only if you have
selected "Alternating operation, time" and if the
pumps are fitted with FM 300.
16.Press [>] to continue.
17.Select "BUS cable" as the communication method
to be used between the two pumps.
18.Press [>] to continue.
19.Press "Select pump 2".
20.Select the additional pump from the list.
Use the [OK] or button to identify the additional
pump.
21.Press [>] to continue.
22.Press [Send].
23.Press [Finish] in the "Setup complete" dialog box.
24.Wait for the green indicator light in the middle of
Grundfos Eye to light up.
The multipump system has now been set.

87
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Advanced control panel and wired pump Disabling a multipump via advanced control panel
User interfaces for TPE pumps

connection 1. Select the "Assist" menu.


1. Connect the two pumps with each other with a 2. Select "Setup of multi-pump system".
3-core screened cable between the GENIbus 3. Press [>] to continue.
terminals A, Y, B.
4. Confirm No multi-pump function by pressing [OK].
2. Set the needed analog and digital inputs according
5. Press [>] to continue.
to the connected equipment and the required
functionality. See "Assisted pump setup" on page 6. Press [OK].
84. The multipump system has now been disabled.
3. Assign pump number 1 to the first pump. See "Description of control mode"
"Number" ("Pump number") on page 80.
4. Assign pump number 2 to the other pump. See "Description of
Pump variant
control mode"
"Number" ("Pump number") on page 80.
TPE3, TPE3 D ●
5. Select the "Assist" menu on one of the pumps and TPE2, TPE2 D ●
choose "Setup of multi-pump system". 2.2 - 11 kW, 2-pole

6. Press [>] to continue. 3 - 7.5 kW, 4-pole
TPE Series 1000
15-22 kW, 2-pole
7. Select Wired GENIbus as the communication -
11 - 18.5 kW, 4-pole
method to be used between the two pumps.
This menu is only available in the advanced control
8. Press [>] twice to continue.
panel.
9. Select the desired multipump function. See
This menu describes each of the possible control
Alternating operation on page 85, Backup operation
modes. See also section "Control mode" on page 59.
on page 85 and Cascade operation on page 86.
10.Press [>] to continue. "Assisted fault advice"
11.Press [OK] to search for other pumps. "Assisted fault
Pump variant
12.Select the additional pump from the list. advice"

13.Press [>] to continue. TPE3, TPE3 D ●


TPE2, TPE2 D ●
14.Set the time for pump changeover such as the time 2.2 - 11 kW, 2-pole
at which the alternation between the two pumps is ●
3 - 7.5 kW, 4-pole
TPE Series 1000
to take place. 15-22 kW, 2-pole
-
This step applies only if you have selected 11 - 18.5 kW, 4-pole

"Alternating operation, time" and if the pumps are This menu gives guidance and corrective actions in
fitted with FM 300. case of pump failures.
15.Press [>] to continue.
16.Press [OK].
The multipump function icons appear in the bottom
of the control panels.
The multipump system has now been set.
Disabling the multipump function via Grundfos GO
1. Select the "Assist" menu.
2. Select "Multipump setup".
3. Select "Disable".
4. Press [>] to continue.
5. Confirm the multipump setup by pressing [Send].
6. Press [Finish].
The multipump function has now been disabled.

88
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Priority of settings

User interfaces for TPE pumps


You can always set the pump to stop by pressing
on the pump control panel. When the pump is not in
"Stop" mode, you can always stop the pump by
continuously pressing . Furthermore, you can set
the pump to maximum speed by continuously pressing
. You can always set the pump to operation at
maximum speed or to stop with Grundfos GO.
If two or more functions are enabled at the same time,
the pump will operate according to the function with
the highest priority.
Example
If you have set the pump to maximum speed via the
digital input, the pump control panel or Grundfos GO
can only set the pump to "Manual" or "Stop".
The priority of the settings appears from the table
below.
Priority Start-stop button Grundfos GO or control panel on the motor Digital input Bus communication

1 "Stop"

2 "Stop"*

3 "Manual"

4 "Max. speed"*/"User-defined speed"

5 "Stop"

6 "User-defined speed"

7 "Stop"

8 "Max. speed"

9 "Min. speed"

10 "Start"

11 "Max. speed"

12 "Min. speed"

13 "Min. speed"

14 "Start"

15 "Start"

* "Stop" and "Max. speed" settings made with Grundfos GO or on the


motor control panel can be overruled by another operating-mode
command sent from a bus, for example "Start". If the bus
communication is interrupted, the motor resumes its previous
operating mode, for example "Stop", selected with Grundfos GO or
on the motor control panel.

89
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Grundfos Eye
User interfaces for TPE pumps

The operating condition of the motor is indicated by


Grundfos Eye on the control panel. See fig. 70 (A).

AA

TM05 5993 4312


Fig. 70 Grundfos Eye

Grundfos Eye Indication Description

The power is off.


No lights are on.
The pump is not running.

The two opposite green indicator lights are rotating in the


The power is on.
direction of rotation of the pump when seen from the
The pump is running.
non-drive end.

The power is on.


The two opposite green indicator lights are permanently on.
The pump is not running.

One yellow indicator light is rotating in the direction of Warning.


rotation of the pump when seen from the non-drive end. The pump is running.

Warning.
One yellow indicator light is permanently on.
The pump has stopped.

Alarm.
The two opposite red indicator lights flash simultaneously.
The pump has stopped.
The green indicator light in the middle flashes quickly four
times. This is a feedback signal which the pump gives in order
to ensure identification of itself.

The green indicator light in the middle flashes continuously. Grundfos GO or another pump is trying to communicate
with the pump. Press on the pump control panel to
allow communication.
The green indicator light in the middle is permanently on. Remote control with Grundfos GO via radio.
The pump is communicating with Grundfos GO via radio
connection.
The green indicator light in the middle flashes quickly while
Grundfos Go is exchanging data with the pump. It takes a Remote control with Grundfos GO via infrared light.
few seconds. The pump is receiving data from Grundfos GO via
infrared communication.

90
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
Indicator lights and signal relays

User interfaces for TPE pumps


The following applies to the pumps below:
• TPE3, TPE3 D pumps
• TPE2, TPE2 D pumps
• TPE Series 1000 pumps with the following motor
sizes:
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole.
The pump has two outputs for potential-free signals via
two internal relays.
You can set the signal outputs to "Operation", "Pump
running", "Ready", "Alarm" and "Warning".
The functions of the two signal relays appear from the
table below:
Contact position for signal relays when activated
"Operating
Description Grundfos Eye "Pump
"Operation" "Ready" "Alarm" "Warning" mode"
running"

The power is off. -

Off C NO NC C NO NC C NO NC C NO NC C NO NC

"Normal",
The pump runs in "Normal"
"Min." or
mode.
"Max."
Green, rotating C NO NC C NO NC C NO NC C NO NC C NO NC

The pump runs in "Manual"


"Manual"
mode.
C NO NC C NO NC C NO NC C NO NC C NO NC
Green, rotating

The pump is in operating


"Stop"
mode "Stop".
Green, steady C NO NC C NO NC C NO NC C NO NC C NO NC

"Normal",
Warning, but the pump runs. "Min." or
"Max."
Yellow, rotating C NO NC C NO NC C NO NC C NO NC C NO NC

Warning, but the pump runs


"Manual"
in "Manual" mode.
Yellow, rotating C NO NC C NO NC C NO NC C NO NC C NO NC

Warning, but the pump was


stopped via "Stop" "Stop"
command.
Yellow, steady C NO NC C NO NC C NO NC C NO NC C NO NC

"Normal,"
Alarm, but the pump runs. "Min." or
"Max."
Red, rotating C NO NC C NO NC C NO NC C NO NC C NO NC

Alarm, but the pump runs in


"Manual"
"Manual" mode.
Red, rotating C NO NC C NO NC C NO NC C NO NC C NO NC

The pump has stopped due


"Stop"
to an alarm.
Red, flashing C NO NC C NO NC C NO NC C NO NC C NO NC

91
12 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

The following applies to the pumps below:


User interfaces for TPE pumps

• TPE Series 1000 pumps with the following motor


sizes:
3-22 kW, 2-pole
3 - 18.5 kW, 4-pole.
The operating condition of the pump is indicated by the
green (A) and red (B) indicator lights on the pump
control panel and inside the terminal box. See fig. 71.

TM06 7513 3616


B

Fig. 71 Position of indicator lights

Furthermore, the pump incorporates an output for a


potential-free signal via an internal relay.

92
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
12
The functions of the two indicator lights and the signal

User interfaces for TPE pumps


relay are as shown in the following table:
Indicator lights Signal relay activated during:

"Pump running"
"Fault"/"Alarm",
"Warning" and
"Relubricate"
Description

"Operating"
Fault Operation
red green

"Ready"
Off Off The power supply has been switched off.

C NO NC C NO NC C NO NC C NO NC

Off Permanently on The pump runs.

C NO NC C NO NC C NO NC C NO NC

Off Flashing The pump has been set to stop.

C NO NC C NO NC C NO NC C NO NC
The pump has stopped because of a "Fault"
or "Alarm". Or the pump runs with a
"Warning" or "Relubricate" indication.
Permanently on Off
If the pump was stopped, restarting will be
C NO NC C NO NC C NO NC C NO NC attempted. It may be necessary to restart
the pump by resetting the "Fault" indication.
The pump runs, but it has or has had a
"Fault" or "Alarm" allowing the pump to
continue operation. Or the pump runs with a
"Warning" or "Relubricate" indication.
If the cause is "Sensor signal outside signal
range", the pump continues to run
according to the maximum curve, and you
Permanently on Permanently on
cannot reset the fault indication until the
C NO NC C NO NC C NO NC C NO NC signal is inside the signal range.
If the cause is "Setpoint signal outside
signal range", the pump continues to run
according to the minimum curve, and you
cannot reset the fault indication until the
signal is inside the signal range.

The pump has been set to stop, but it has


Permanently on Flashing
been stopped because of a "Fault".
C NO NC C NO NC C NO NC C NO NC

Resetting of fault indication


You can reset a fault indication in one of the following
ways:
• Briefly press or on the pump. This will not
change the setting of the pump.
You cannot reset a fault indication by pressing or
if the buttons have been locked.
• Switch off the power supply until the indicator lights
are off.
• Switch the external start-stop input off and then on
again.
• Use Grundfos GO.

93
13 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

13. Factory settings of E-pumps


Factory settings of E-pumps

● Function is enabled.
❍ Function is disabled.
- Function is not available.

11 - 18.5 kW, 4-pole


2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole

15-22 kW, 2-pole


TPE Series 1000

TPE Series 1000


TPE3, TPE3 D

TPE2, TPE2 D
Function
Settings Comments
description

"Setpoint" Auto 67 % 67 % 67 % Page 58


"Operating mode" Normal Normal Normal Normal Page 59
"Control mode" AutoAdapt Constant curve Constant curve Constant curve Page 59
"Date and time" ● ● ● - Page 81
"Flow limit" ❍ - - - Page 66
"Automatic night setback" ❍ - - - Page 67
"Temperature influence" ❍ - - - Page 77
"Buttons on product" ● ● ● ● Page 81
"Controller"
"Kp" 1.0 0.5 0.5 0.5 Page 73
"Ti" 8.0 0.5 0.5 0.5
"Operating range"
"Min." 25 % 25 % 25 % 25 % Page 74
"Max." 100 % 100 % 110 % 110 %
"Ramps" - ❍ ❍ - Page 79
"Pump number" 1 1 1 1 Page 80
"Radio communication" ● ● ● - Page 80
"Sensor type" - - - ❍ Page 67
"Analog input 1" ❍ ❍ ❍ -
"Analog input 2" ❍ ❍ ❍ - Page 67
"Analog input 3" ❍ ❍ ❍ -
"Built-in Grundfos sensor" ● - - - Page 68
"Pt100/1000 input 1" ❍ ❍ ❍ -
Page 69
"Pt100/1000 input 2" ❍ ❍ ❍ -
"Digital input 1" ❍ ❍ ❍ -
Page 69
"Digital input 2" ❍ ❍ ❍ ❍
"Digital in/output 3" ❍ ❍ ❍ -
Page 71
"Digital in/output 4" ❍ ❍ ❍ -
"Pulse flowmeter" ❍ ❍ ❍ - Page 79
"Predefined setpoint" ❍ ❍ ❍ - Page 77
"Analog output" 1) ❍ ❍ ❍ - Page 72
"External setpoint funct." ❍ ❍ ❍ ❍ Page 75
"Signal relay 1" ❍ ❍ ❍ Alarm
Page 72
"Signal relay 2" ❍ ❍ ❍ Operation
"Limit 1 exceeded" ❍ ❍ ❍ -
Page 78
"Limit 2 exceeded" ❍ ❍ ❍ -
"Standstill heating" ❍ ❍ ❍ ❍ Page 79
"Motor bearing monitoring" ❍ ❍ ❍ ❍ Page 79
"Pump name" Grundfos Grundfos Grundfos - Page 82
"Connect code" - - - - Page 83
"Unit configuration" SI units SI units SI units SI units Page 81

Multipump factory setting for twin-pumps: Alternating operation on time.

94
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
14

14. Communication

Communication
Communication with TPE2, TPE2
D, TPE3, TPE3 D and TPE pumps
Communication with TPE2, TPE2 D, TPE3, TPE3 D
and TPE pumps is possible via a central building
management system, remote control, Grundfos GO or
control panel.
Central building management system
The operator can communicate with a TPE2, TPE2 D,
TPE3, TPE3 D and TPE pump at a distance.
Communication can take place via a central building
management system allowing the operator to monitor
and change control modes and setpoint settings.

CIM 050: GENIbus


CIM 100: LonWorks
CIM 150: PROFIBUS DP
CIM 200: Modbus RTU
CIM 250: GSM/GPRS
CIM 270: GRM
CIM 300: BACnet MS/TP
CIM 500: Modbus TCP
CIM 500: PROFINET
TM06 7405 3316

Fig. 72 Structure of a central building management system

Remote control
The operator can monitor and change control modes
and settings of the pump with Grundfos GO. See
Grundfos GO on page 54.

95
15 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

15. Speed regulation of TPE, TPE2, TPE2 D, TPE3, TPE3 D


Speed regulation of TPE, TPE2, TPE2 D, TPE3, TPE3 D

pumps
Affinity equations H
Q n
Normally, the pumps are used in applications n n
--------  ------
Q n
characterised by a variable flow. Consequently, you Hn
x x
cannot to select a pump that is constantly operating at
its optimum efficiency. H  n n 2
Hx nn n
-------   ------
In order to achieve optimum operating economy, the H
x  n x
nx
duty pump must be close to the optimum efficiency,
eta, for most operating hours.
Between the minimum and maximum performance
Q
curves, the pumps have an infinite number of Eta
Qx Qn
performance curves each representing a specific 
n
speed. Therefore, you may not be able to select a duty -------  1

x
point close to the maximum curve.
H
H
[m] nx nn
[m]
Maximum curve

Q
P Qx Qn
Pn  n n 3
-------   ------
nn Px  n x
Pn
Minimum curve

TM00 8720 3496


Px nx
TM01 4916 4803

0 Q
3
0 QQ[m³/h]
[m h] Fig. 74 Affinity equations

Fig. 73 Minimum and maximum performance curves Legend


In situations where you can select a duty point close to Hn Rated head in metres
the maximum curve, use the affinity equations below. Hx Current head in metres
The head, H, the flow rate, Q and the input power, P, Qn Rated flow rate in m3/h
are the appropriate variables you need for calculating
Qx Current flow rate in m3/h
the motor speed, n.
nn Rated motor speed in min-1
Note: The approximated formulas apply on condition
nx Current motor speed in min-1
that the system characteristic remains unchanged for
ηn Rated efficiency in %
the rated motor speed and the current motor speed,
and that it is based on the following formula: H is equal ηx Current efficiency in %
to k x Q2 where k is a constant. Pn Rated power in kW
The power equation implies that the pump efficiency is Px Current power in kW
unchanged at the two speeds. In practice, this is not Grundfos Product Center
quite correct.
Grundfos Product Center can help you select the right
Finally, it is worth noting that the efficiencies of the pump according to your requirements. See page 224.
frequency converter and the motor must also be taken
into account if you want a precise calculation of the
power saving resulting from a reduction of the pump
speed.

96
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
16

16. Control of pumps in parallel

Control of pumps in parallel


In some applications, parallel pump operation is Pumps connected to Control MPC
required for one or more of the following reasons:
You can connect TP, TPE, TPE2, TPE3 pumps directly
• One pump cannot achieve the required to Grundfos Control MPC.
performance, flow rate.
Control MPC incorporates a CU 352 control unit that
• Standby performance is required to ensure reliability can control up to six pumps.
of supply.
By means of an external sensor, Control MPC can
• Overall efficiency needs to be improved in case of ensure optimum adaptation of the performance to the
big variations in the flow demand. demand by closed-loop control of these parameters:
The table below lists the different possibilities of • proportional differential pressure
controlling pumps connected in parallel.
• constant differential pressure
• differential pressure (remote)

TPE Series 1000


• flow rate
• temperature.
The CU 352 incorporates features such as those
below:
Parallel-operation control
11 - 18.5 kW, 4-pole
possibilities Startup wizard
2.2 - 11 kW, 2-pole
3 - 7.5 kW, 4-pole
15-22 kW, 2-pole

Correct installation and commissioning is a


prerequisite for attaining optimum performance of the
system and trouble-free operation year in and year out.
TPE2 D

TPE3 D
TPE2

TPE3

During commissioning of the system, a startup wizard


TP

is shown on the display of CU 352. The wizard guides


Built-in
alternation/standby ● ● ● ● ● ❍
the operator through the various steps via a series of
function dialogue boxes to ensure that all settings are done in
Built-in parallel operation
the correct sequence.
● ● ● ● ●
function
Application-optimised software
Control MPC
The CU 352 incorporates application-optimised
software which helps you set your system to the
application in question.
● ● ● ● Furthermore, navigating through the menus of the
control unit is done in a user-friendly way. You do not
need any training to be able to set and monitor the
system.
Control MPC Series 2000 Ethernet connection
The CU 352 incorporates an ethernet connection
which makes it possible to get full and unlimited
● access to the setting and monitoring of the system via
a remote PC.
Service port, GENI TTL
The service port of the CU 352 enables easy access to
● Available.
updating software and data logging in service
❍ Available on request. situations.
External communication
Alternation/standby function
Control MPC enables communication with other
The alternation/standby function is activated from
fieldbus protocols. In order to communicate with other
factory and "Alternating" mode is selected as default.
fieldbus protocols, a GENIbus module and a gateway
See pages 40 and 35.
are required.
Control MPC can communicate with LonWorks,
PROFIBUS, Modbus, BACnet, GSM/GPRS or GRM via
Grundfos CIU.

97
16 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Pumps connected to Control MPC Series


Control of pumps in parallel

2000
TPE3 pumps are connected directly to Grundfos
Control MPC Series 2000 via GENIbus.
Control MPC Series 2000 incorporates a CU 352
control unit that can control up to six pumps.
All pumps must be of the same type and size.
Control MPC Series 2000 is used for controlling
circulator pumps in heating and air-conditioning
applications.
Control MPC Series 2000 ensures optimal adaptation
of the performance to the demand by closed-loop
control of these parameters:
• proportional differential pressure
• constant differential pressure.
By means of an external sensor Control MPC Series
2000 can also ensure optimum adaptation of the
performance to the demand by closed-loop control of
these parameters:
• differential pressure (remote)
• flow rate
• temperature.
Note: For further information about Control MPC and
Control MPC Series 2000, see the data booklet
"Control MPC". The data booklet is available online in
Grundfos Product Center. See page 224.

98
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
17

17. Grundfos CUE

Grundfos CUE
TP pumps connected to Grundfos Smart user interface

CUE, external frequency


converters

TM04 3283 4108


Fig. 76 Grundfos CUE user interface

The frequency converter features a unique


user-friendly control panel with graphic display and
GrA 4404 easy-to-use buttons.
Controlling the value you choose
Fig. 75 Grundfos CUE product range The frequency converter has a built-in PI controller
offering closed-loop control of a desired value.
Grundfos CUE is a complete range of wall-mounted The values include:
frequency converters for pump control in a wide range
• constant differential pressure
of applications.
• proportional pressure
The frequency converter provides a variety of benefits
such as these: • constant temperature
• Grundfos E-pump functionality and user interface. • constant pressure
• application- and pump family-related functions. • constant flow.
• increased comfort compared to fixed-speed pump Wide product range
solutions. The CUE product range is quite comprehensive,
• simple installation and commissioning compared to covering five different voltage ranges, enclosure
standard frequency converters. classes IP20/21 (Nema 1) and IP54/55 (Nema 12), and
• speed control of pumps up to 250 kW. a wide range of output powers.
The table below provides a general overview.
Functions
Input voltage [V] Output voltage [V] Motor [kW]
Intuitive startup guide 1 x 200-240 3 x 200-240 1.1 - 7.5
The startup guide enables easy installation and 3 x 200-240 3 x 200-240 0.75 - 45
commissioning as well as plug-and-pump 3 x 380-500 3 x 380-500 0.55 - 250
3 x 525-600 3 x 525-600 0.75 - 7.5
convenience. Few settings need to be made by the
3 x 525-690 3 x 525-690 11-250
installer as the rest is done automatically or preset
from the factory.
External communication
The frequency converter can communicate with LON,
PROFIBUS, Modbus, BACnet or GSM/GPRS via
Grundfos CIU.

99
18 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

18. Motor data


Motor data

Motor Motor range

The motor fitted on TP pumps is a totally enclosed, Mains-operated motors


Electronically
fan-cooled motor with main dimensions to IEC and DIN speed-controlled motors
kW
standards. Electrical tolerances to IEC 34. 2-pole 4-pole 2-pole 4-pole

Mounting designation 0.25

0.37
Pump type Mounting designation - IEC 34-7
TP Series 200 IM 3601 (IM B 14) / IM 3611 (IM V 18) 0.55

TP Series 300 IM 3001 (IM B 5) / IM 3011 (IM V 1) 0.75

1.1
Relative humidity: Maximum 95 %
Enclosure class: IP55 1.5
Insulation class: F (IEC 85) 2.2 MG
Ambient temperature: See page 18.
3.0
MG MGE*
If the pump is installed in humid locations, open the 4.0
lowest drain hole in the motor. This will reduce the MGE*
5.5
motor enclosure class to IP44.
7.5
High-efficiency motors
11.0
TP pumps are primarily fitted with motors that meet the
legislative requirements of the EuP IE3 or IE2 grade 15.0 MGE
depending on voltage and motor size. For further 18.5 MGE
information see pages 101 to 104.
22.0
TPE2, TPE2 D, TPE3, TPE3 D pumps are fitted with
Grundfos permanent-magnet MGE motors that have 30.0
motor efficiency class IE5 according to IEC 37.0
60034-30-2.
45.0
TPE pumps with 2-pole motors up to 11 kW and 4-pole
motors up to 7.5 kW are fitted with Grundfos 55.0
permanent-magnet MGE motors that have motor 75.0
efficiency class IE5 according to IEC 60034-30-2. Siemens
90.0 Siemens
TPE pumps with three-phase 2-pole motors from 15 to
22 kW are fitted with motors equivalent to IE3. 110.0

TPE pumps with three-phase 4-pole motors from 11 to 132.0


15 kW are fitted with motors equivalent to IE3. 160.0
TPE pumps with 4-pole three-phase motors of 18.5 kW
200.0
are equipped with motors equivalent to IE2.
250.0

315.0

* IE5 motors

MG and MGE are Grundfos motor brands.


Siemens is a sourced high-quality motor brand.
The grey-shaded areas indicate non-available motors.

100
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
18
Electrical data, mains-operated motors

Motor data
Electrical data, 2-pole 3 x 220-240/380-420 V and 3 x 255-277/440-480 V

3 x 220-240/380-420 V 3 x 255-277/440-480 V

Motor I1/1 η* n* IStart IE Motor I1/1 η** n** IStart IE


Cos φ 1/1 * ------------ Cos φ 1/1 ** ------------
[kW] [A] [%] [min-1] I 1/1 class [kW] [A] [%] [min-1] I 1/1 class
30.0 97.0 - 87.0 / 56.0 - 50.0 0.89 92.4 3545 6.1 IE3 34.5 94.0 - 87.0 / 54.0 - 50.0 0.87 93.0 3550 6.6 IE3
37.0 120-105 / 69.0 - 62.0 0.90 93.0 3540 5.8 IE3 42.5 116-107 / 67.0 - 61.0 0.87 93.6 3550 6.7 IE3
45.0 140-126 / 81.0 - 73.0 0.90 94.2 3556 7.6 IE3 51.0 137-128 / 79.0 - 74.0 0.89 93.6 3560 6.8 IE3
55 166-154 / 96-89 0.901 94.0 3570 7.3 IE3 62 166-154 / 96-89 0.90 93.6 3575 6.7 IE3
75 235-210 / 135-122 0.898 93.8 3570 7.4 IE3 84 225-210 / 130-122 0.89 94.5 3575 6.8 IE3
90 280-250 / 161-145 0.907 94.4 3570 7.8 IE3 101 270-250 / 156-143 0.90 94.5 3575 7.2 IE3
110 335-300 / 194-174 0.907 95.1 3579 7.8 IE3 123 320-295 / 186-171 0.91 95.0 3582 7.2 IE3
132 400-265 / 230-210 0.92 94.8 3579 8.0 IE3 148 390-355 / 225-205 0.91 95.4 3582 7.1 IE3
160 450-405 / 260-235 0.92 95.3 3582 9.1 IE3 180 470-435 / 270-250 0.92 95.4 3582 7.7 IE3

* Applies to 230/400 V
** Applies to 265/460 V

Electrical data, 2-pole 3 x 220-255/380-440 V Electrical data, 2-pole 3 x 380-480/660-690 V

Motor I1/1 IStart IE Motor I1/1 IStart IE


Cos φ 1/1 η [%] n [min-1] ------------ Cos φ 1/1 η [%] n [min-1] ------------
[kW] [A] I 1/1 class [kW] [A] I 1/1 class
1.5-1.44 / 1.5 3.1-2.7 0.90-0.81 82.5-85.5 3470-3530 7.8-10.5 IE2-IE3
0.37 0.85-0.76 78-79 3410-3470 5.5-6.5 -
0.87-0.83 2.2 4.45-3.7 0.91-0.85 85.2-86.5 3470-3530 7.8-11 IE2-IE3
2.15-2.05 / 3.0 6.2-5.4 0.91-0.84 87.5 3480-3530 8.6-11 IE2
0.55 0.85-0.76 80.5-82 3390-3460 5-6 -
1.25-1.2
4.0 7.8-6.8 0.91-0.82 88.5 3510-3540 10.8-10.8 IE3
2.95-2.75 /
0.75 0.86-0.77 77 3410-3470 6-7.4 IE3 5.5 10.6-9.30 0.9-0.80 89.5 3510-3550 10.2-14.8 IE3
1.70-1.60
14.2-12.0 /
4.15-4.00 / 7.5 0.90-0.82 89.5-90.2 3490-3530 6.8-10.5 IE2-IE3
1.1 0.88-0.80 82.5 3420-3470 4.3-5 IE3 8.20-8.10
2.40-2.30
20.8-17.2 /
11.0 0.89-0.83 90.2-91.0 3520-3550 5.8-8.9 IE2-IE3
Electrical data, 2-pole 3 x 220-277/380-480 V 12.0-11.6
28.0-22.4 /
15.0 0.90-0.86 90.2-91.0 3520-3550 5.8-8.9 IE2-IE3
IStart 16.2-15.6
Motor I1/1 IE
Cos φ 1/1 η [%] n [min-1] ------------ 34.0-27.0 /
[kW] [A] I 1/1 class 18.5 0.90-0.88 91.0-91.7 3520-3550 6.1-9.7 IE2-IE3
19.6-18.8
5.35-4.7 /
1.5 0.90-0.81 82.5-85.5 3470-3530 7.8-10.5 IE2-IE3 40.0-32.5 /
3.10-2.7 22.0 0.91 91.7 3520-3560 6.5-10.4 IE3
23.0-22.2
7.7-6.35 /
2.2 0.91-0.85 85.2-86.5 3470-3530 7.8-11 IE2-IE3
4.45-3.7
10.8-9.35 /
3.0 0.91-0.84 87.5 3480-3530 8.6-11 IE2-IE3
6.20-5.40
13.6-11.8 /
4.0 0.91-0.82 88.5 3510-3540 10-14 IE3
7.8-6.8
18.4-16.2 /
5.5 0.90-0.80 89.5 3510-3550 10.2-14.8 IE3
10.6-9.30
24.6-20.8 /
7.5 0.90-0.82 89.5-90.2 3490-3530 6.8-10.5 IE2-IE3
14.2-12.0
36.0-30.0 /
11.0 0.89-0.83 90.2-91 3520-3550 5.8-8.9 IE2-IE3
20.8-17.2
48.5-39.0 /
15.0 0.90-0.86 90.2-91 3520-3550 5.8-8.9 IE2-IE3
28.0-22.4
59.0-47.0 /
18.5 0.90-0.88 91.0-91.7 3520-3550 6.1-9.7 IE2-IE3
34.0-27.0
69.5-56.5 /
22.0 0.91 91.7 3520-3560 6.5-10.4 IE3
40.0-32.5

101
18 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Electrical data, 2-pole 3 x 380-420/660-690 V and 3 x 440-480 V


Motor data

3 x 380-420/660-690 V 3 x 440-480 V

Motor I1/1 η* n* IStart IE Motor I1/1 η** n** IStart IE


Cos φ 1/1 * ------------ Cos φ 1/1 **
[kW] [A] [%] [min-1] I 1/1 class [kW] [A] [%] [min-1] ------------
I 1/1 class

30.0 56.0 - 50.0 / 32.0 - 30.5 0.89 92.4 3545 6.1 IE3 34.5 54.0 - 50.0 0.87 93.0 3550 6.6 IE3
37.0 69.0 - 62.0 / 38.5 - 37.0 0.90 93.0 3540 5.8 IE3 42.5 67.0 - 61.0 0.87 93.6 3550 6.7 IE3
45.0 81.0 - 73.0 / 47.0 - 44.5 0.90 94.2 3556 7.6 IE3 51.0 79.0 - 74.0 0.89 93.6 3560 6.8 IE3
55.0 96.0 - 89.0 / 55.0 - 54.0 0.90 94.0 3570 7.3 IE3 62.0 96.0 - 89.0 0.90 93.6 3575 6.7 IE3
75.0 135-122 / 78.0 - 74.0 0.90 93.8 3570 7.4 IE3 84.0 130-122 0.89 94.5 3575 6.8 IE3
90.0 161-145 / 93.0 - 88.0 0.91 94.4 3570 7.8 IE3 101.0 156-143 0.90 94.5 3575 7.2 IE3
110.0 194-174 / 112-106 0.91 95.1 3579 7.8 IE3 123.0 186-171 0.91 95.0 3582 7.2 IE3
132.0 230-210 / 133-127 0.92 94.8 3579 8.0 IE3 148.0 225-205 0.91 95.4 3582 7.1 IE3
160.0 260-235 / 150-142 0.92 95.3 3582 9.1 IE3 180.0 270-250 0.92 95.4 3582 7.7 IE3
- - - - - - - 224.0 335-305 0.92 95.8 3582 7.1 IE3
- - - - - - - 280.0 420-385 0.92 95.4 3585 8.7 IE3

* Applies to 400/690 V
** Applies to 400 V

Electrical data, 4-pole 3 x 220-240/380-420 V and 3 x 255-277/440-480 V

3 x 220-240/380-420 V 3 x 255-277/440-480 V

Motor I1/1 η* n* IStart IE Motor I1/1 η** n** IStart IE


Cos φ 1/1 * ------------ Cos φ 1/1** ------------
[kW] [A] [%] [min-1] I 1/1 class [kW] [A] [%] [min-1] I 1/1 class

18.5 63.0 - 57.0 / 36.5 - 33.0 0.84 92.4 1765 6.2 IE3 21.3 62.5 - 57.0 / 36.0 - 33.0 0.83 93.6 1770 7.0 IE3
22 73.5 - 70 / 42.5 - 40.5 0.84 92.4 1765 6.0 IE3 25.3 74.5 - 70.0 / 43.0 - 40.5 0.83 93.6 1770 6.9 IE3
30 99.5 - 93.5 / 57.5 - 54.0 0.85 93.0 1765 6.1 IE3 34.5 99.0 - 92.5 / 57.0 - 53.5 0.85 93.0 1770 7.2 IE3
37 120-109 / 69-63 0.86 94.0 1776 5.4 IE3 42.5 119-111 / 69-64 0.86 93.6 1778 6.7 IE3
45 147-132 / 85-76 0.86 94.3 1775 5.3 IE3 52 146-137 / 84-79 0.86 94.1 1778 6.6 IE3
55 177-159 / 102-92 0.87 94.7 1780 5.4 IE3 63.0 175-163 / 101-94 0.87 94.1 1782 6.7 IE3
75 240-215 / 139-125 0.87 94.8 1783 5.4 IE3 86.0 235-220 / 136-127 0.87 95.4 1785 6.8 IE3
90 290-260 / 166-150 0.87 94.9 1783 5.6 IE3 104 285-265 / 165-153 0.87 95.0 1785 7.0 IE3
110 345-315 / 200-181 0.87 95.4 1786 5.5 IE3 127 345-320 / 199-185 0.87 95.8 1788 6.9 IE3
132 415-370 / 240-215 0.88 95.8 1788 5.8 IE3 152 405-375 / 235-220 0.88 96.2 1788 7.2 IE3
160 470-425 / 270-245 0.88 96.1 1789 5.8 IE3 184 495-460 / 285-265 0.88 96.2 1788 7.2 IE3
200 580-520 / 335-300 0.88 95.7 1788 6.0 IE3 230 620-580 / 360-335 0.88 95.4 1788 7.5 IE3

* Applies to 230/400 V
** Applies to 265/460 V

Electrical data, 4-pole 3 x 220-255/380-440 V

Motor I1/1 IStart IE


Cos φ 1/1 η [%] n [min-1] ------------
[kW] [A] I 1/1 class

0.12 0.37 - - - - -
0.25 1.21 / 0.7 0.8 - 0.69 71-72 1680-1720 4 - 4.7 -
0.37 1.72 / 0.99 0.82 - 0.72 73-74 1680-1720 4 - 4.7 -
0.55 2.4 / 1.4 0.83 - 0.75 77-80 1660-1710 3.9 - 4.5 -
0.75 3.1 / 1.8 0.84 - 0.76 77-81 1660-1710 3.9 - 4.7 IE2

102
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
18
Electrical data, 4-pole 3 x 220-277/380-480 V Electrical data, 4-pole 3 x 380-480/660-690 V

Motor data
Motor I1/1 IStart IE Motor I1/1 IStart IE
Cos φ 1/1 η [%] n [min-1] ------------ Cos φ 1/1 η [%] n [min-1] ------------
[kW] [A] I 1/1 class [kW] [A] I 1/1 class

3.10-2.95 / 0.75 1.80-1.70 0.79-0.67 82.5-85.5 1730-1760 5.9-7.5 IE2-IE3


0.75 0.79-0.67 82.5-85.5 1730-1760 5.9-7.5 IE2-IE3
1.80-1.70 1.1 2.60-2.60 0.76-0.60 84 1740-1770 7.1-9.1 IE2
1.1 4.50 /2.60 0.76-0.60 84.0 1740-1770 7.1-9.1 IE2 1.5 3.40-3.25 0.78-0.65 84-86.5 1740-1770 6.6-9.3 IE2-IE3
5.90-5.65 / 2.2 4.70-4.30 0.83-0.71 87.5 1740-1760 5.9-7.6 IE2
1.5 0.78-0.65 84.0-86.5 1740-1770 6.6-9.3 IE2-IE3
3.40-3.25
3.0 6.10-5.50 0.85-0.73 87.5-89.5 1730-1760 6.2-8.8 IE2-IE3
8.15-7.45 /
2.2 0.83-0.71 87.5 1740-1760 5.9-7.6 IE2 4.0 8.60-8.30 0.79-0.64 87.5-89.5 1750-1770 7.7-9.1 IE2-IE3
4.70-4.30
11.0-9.40 /
10.6-9.55 / 5.5 0.88-0.79 87.0-89.5 1750-1770 6.7-8.5 IE2-IE3
3.0 0.85-0.73 87.5-89.5 1730-1760 6.2-8.8 IE2-IE3 6.35-6.20
6.10-5.50
14.7-12.5 /
14.8-14.4 / 7.5 0.88-0.80 89.5-91.7 1740-1770 5.9-8.9 IE2-IE3
4.0 0.79-0.64 87.5-89.5 1750-1770 7.7-9.1 IE2-IE3 8.50-8.25
8.60-8.30
20.8-17.8 /
19.0-16.2 / 11.0 0.90-0.81 91 1760-1780 6.5-9.7 IE2
5.5 0.88-0.79 87.0-89.5 1750-1770 6.7-8.5 IE2 12.0-11.8
11.0-9.40
29.0-24.2 /
25.5-21.6 / 15.0 0.88-0.81 91 1760-1770 6.5-9.8 IE2-IE3
7.5 0.88-0.80 89.5-91.7 1740-1770 5.9-8.9 IE2-IE3 16.6-16.4
14.7-12.5
36.0-31.0 /
11.0 0.90-0.81 91.0 1760-1780 6.5-9.7 IE2
20.8-17.8
50-42 /
15.0 0.88-0.81 91.0 1760-1770 6.5-9.8 IE2-IE3
29-24.2

Electrical data, 4-pole 3 x 380-420/660-690 V and 3 x 440-480 V


3 x 380-420/660-690 V 3 x 440-480 V

Motor I1/1 η* n* IStart IE Motor I1/1 η** n** IStart IE


Cos φ 1/1 * ------------ Cos φ 1/1 ** ------------
[kW] [A] [%] [min-1] I 1/1 class [kW] [A] [%] [min-1] I 1/1 class

18.5 36.5 - 33.0 / 21.0 - 20.0 0.84 92.4 1765 6.2 IE3 21.3 36.0 - 33.0 0.83 93.6 1770 7.0 IE3
22.0 42.5 - 40.5 / 24.5 - 24.0 0.84 92.4 1765 6.0 IE3 25.3 43.0 - 40.5 0.83 93.6 1770 6.9 IE3
30.0 57.5 - 54.0 / 33.5 - 32.0 0.85 93.0 1765 6.1 IE3 34.5 57.0 - 53.5 0.85 93.0 1770 7.2 IE3
37.0 69.0 - 63.0 / 40.0 - 38.0 0.86 94.0 1776 5.4 IE3 42.5 69.0 - 64.0 0.86 93.6 1778 6.7 IE3
45.0 85.0 - 76.0 / 49.0 - 46.0 0.86 94.3 1775 5.3 IE3 52.0 84.0 - 79.0 0.86 94.1 1778 6.6 IE3
55.0 102 - 92.0 / 59.0 - 56.0 0.87 94.7 1780 5.4 IE3 63.0 101 - 94.0 0.87 94.1 1782 6.7 IE3
75.0 139-125 / 80.0 - 76.0 0.87 94.8 1783 5.4 IE3 86.0 136-127 0.87 95.4 1785 6.8 IE3
90.0 166-150 / 96.0 - 91.0 0.87 94.9 1783 5.6 IE3 103.5 165-153 0.87 95.0 1785 7.0 IE3
110.0 200-181 / 115-109 0.87 95.4 1786 5.5 IE3 126.5 199-185 0.87 95.8 1788 6.9 IE3
132.0 240-215 / 138-131 0.88 95.8 1788 5.8 IE3 151.8 235-220 0.88 96.2 1788 7.2 IE3
160.0 270-245 / 156-148 0.88 96.1 1789 5.8 IE3 184.0 285-265 0.88 96.2 1788 7.2 IE3
200.0 335-300 / 192-182 0.88 95.7 1788 6.0 IE3 230.0 360-335 0.88 95.4 1788 7.5 IE3
250.0 415-370 / 240-225 0.86 95.9 1789 7.7 IE3 - - - - - - -
300.0 560-500 / 320-305 0.85 95.9 1788 7.9 IE3 - - - - - - -

* Applies to 400/690 V
** Applies to 400 V

103
18 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Electrical data, speed-controlled motors


Motor data

Electrical data, 1 x 200-240 V, TPE2, TPE3 pumps Electrical data, 2-pole 3 x 380-500 V, 4000 min-1
Motor Motor [kW] I1/1 [A]
Pump type I1/1 [A]
[kW]
2.2 4.15 - 3.40
TPE2, TPE2 D, TPE3, TPE3 D 32-80 0.25 1.56 3 5.80 - 4.80
TPE2, TPE2 D, TPE3, TPE3 D 32-120 0.25 1.56 4 7.60 - 6.20
TPE2, TPE2 D, TPE3, TPE3 D 32-150 0.37 2.29 5.5 10.3 - 8.20
TPE2, TPE2 D, TPE3, TPE3 D 32-180 0.55 3.15 7.5 14.1 - 11.2
TPE2, TPE2 D, TPE3, TPE3 D 32-200 0.75 4.17 11 20.3 - 16.0
TPE2, TPE2 D, TPE3, TPE3 D 40-80 0.25 1.56
TPE2, TPE2 D, TPE3, TPE3 D 40-120 0.37 2.17 Electrical data, 4-pole 3 x 380-500 V, 2000 min-1
TPE2, TPE2 D, TPE3, TPE3 D 40-150 0.55 3.04
TPE2, TPE2 D, TPE3, TPE3 D 40-180 0.75 4.17 Motor [kW] I1/1 [A]
TPE2, TPE2 D, TPE3, TPE3 D 40-200 1.1 5.97 1.5 2.90 - 2.50
TPE2, TPE2 D, TPE3, TPE3 D 40-240 1.5 8.00 2.2 4.30 - 3.60
TPE2, TPE2 D, TPE3, TPE3 D 50-60 0.37 2.17 3 5.80 - 4.60
TPE2, TPE2 D, TPE3, TPE3 D 50-80 0.37 2.17 4 7.70 - 6.00
TPE2, TPE2 D, TPE3, TPE3 D 50-120 0.55 3.04 5.5 10.5 - 8.40
TPE2, TPE2 D, TPE3, TPE3 D 50-150 0.75 4.1 7.5 14.1 - 11.1
TPE2, TPE2 D, TPE3, TPE3 D 50-180 1.1 5.97
TPE2, TPE2 D, TPE3, TPE3 D 50-200 1.5 8.00 Electrical data, 2-pole 3 x 380-480 V, 2900 min-1
TPE2, TPE2 D, TPE3, TPE3 D 65-60 0.37 2.17
TPE2, TPE2 D, TPE3, TPE3 D 65-80 0.55 3.04 Motor [kW] I1/1 [A]
TPE2, TPE2 D, TPE3, TPE3 D 65-120 0.75 4.10 15.0 30.0 - 26.0
TPE2, TPE2 D, TPE3, TPE3 D 65-150 1.1 5.97 18.5 37.0 - 31.0
TPE2, TPE2 D, TPE3, TPE3 D 65-180 1.5 8.00 22.0 43.5 - 35.0
TPE2, TPE2 D, TPE3, TPE3 D 80-40 0.25 1.46
TPE2, TPE2 D, TPE3, TPE3 D 80-120 1.1 5.88 Electrical data, 4-pole 3 x 380-480 V, 1450 min-1
TPE2, TPE2 D, TPE3, TPE3 D 80-150 1.5 7.97
TPE2, TPE2 D, TPE3, TPE3 D 100-40 0.25 1.46 Motor [kW] I1/1 [A]
TPE2, TPE2 D, TPE3, TPE3 D 100-120 1.1 5.88 11.0 22.0 - 17.8
TPE2, TPE2 D, TPE3, TPE3 D 100-150 1.5 7.97 15.0 30.0 - 25.4
18.5 37.0 - 30.0
Electrical data, 3 x 380-500 V, TPE2, TPE2 D, TPE3,
TPE3 D pumps

Motor
Pump type I1/1 [A]
[kW]
TPE2, TPE2 D, TPE3, TPE3 D 32-80 0.25 0.88
TPE2, TPE2 D, TPE3, TPE3 D 32-120 0.25 0.88
TPE2, TPE2 D, TPE3, TPE3 D 32-150 0.37 1.09
TPE2, TPE2 D, TPE3, TPE3 D 32-180 0.55 1.34
TPE2, TPE2 D, TPE3, TPE3 D 32-200 0.75 1.68
TPE2, TPE2 D, TPE3, TPE3 D 40-80 0.25 0.88
TPE2, TPE2 D, TPE3, TPE3 D 40-120 0.37 1.09
TPE2, TPE2 D, TPE3, TPE3 D 40-150 0.55 1.34
TPE2, TPE2 D, TPE3, TPE3 D 40-180 0.75 1.68
TPE2, TPE2 D, TPE3, TPE3 D 40-200 1.1 2.26
TPE2, TPE2 D, TPE3, TPE3 D 40-240 1.5 2.96
TPE2, TPE2 D, TPE3, TPE3 D 50-60 0.37 1.04
TPE2, TPE2 D, TPE3, TPE3 D 50-80 0.37 1.04
TPE2, TPE2 D, TPE3, TPE3 D 50-120 0.55 1.34
TPE2, TPE2 D, TPE3, TPE3 D 50-150 0.75 1.68
TPE2, TPE2 D, TPE3, TPE3 D 50-180 1.1 2.26
TPE2, TPE2 D, TPE3, TPE3 D 50-200 1.5 2.96
TPE2, TPE2 D, TPE3, TPE3 D 50-240 2.2 4.22
TPE2, TPE2 D, TPE3, TPE3 D 65-60 0.37 1.04
TPE2, TPE2 D, TPE3, TPE3 D 65-80 0.55 1.34
TPE2, TPE2 D, TPE3, TPE3 D 65-120 0.75 1.68
TPE2, TPE2 D, TPE3, TPE3 D 65-150 1.1 2.15
TPE2, TPE2 D, TPE3, TPE3 D 65-180 1.5 2.96
TPE2, TPE2 D, TPE3, TPE3 D 65-200 2.2 4.22
TPE2, TPE2 D, TPE3, TPE3 D 80-40 0.25 0.82
TPE2, TPE2 D, TPE3, TPE3 D 80-120 1.1 2.15
TPE2, TPE2 D, TPE3, TPE3 D 80-150 1.5 2.82
TPE2, TPE2 D, TPE3, TPE3 D 80-180 2.2 4.03
TPE2, TPE2 D, TPE3, TPE3 D 100-40 0.25 0.82
TPE2, TPE2 D, TPE3, TPE3 D 100-120 1.1 2.15
TPE2, TPE2 D, TPE3, TPE3 D 100-150 1.5 2.82
TPE2, TPE2 D, TPE3, TPE3 D 100-180 2.2 4.03

104
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
19

19. Installation

Installation
Mechanical installation
You can install TP pumps with motors smaller than 11
kW in horizontal or vertical pipes.

TM00 3734 0897


Fig. 77 Installation of motor sizes smaller than 11 kW

You can suspend pumps with motors smaller than 11


kW directly in the pipes, provided the pipes can
support the pump. If not, install the pump on a
mounting bracket or base plate.
Only install TP pumps with motors of 11 kW and up in
horizontal pipes with the motor in vertical position.
Always install the pump on an even and rigid
foundation.
TM00 3735 0897

Fig. 78 Installation of motor sizes of 11 kW and up

Note: The motor must never point downwards.


Install the pumps in such a way that strain from the
pipes is not transferred to the pump housing.
However, you can suspend some TP, TPE pumps of 11
kW and up directly in the pipes, either horizontally or
vertically. See the table TP, TPE pumps from 11 kW
and up suspended in the pipes on page 106.

105
19 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

TP, TPE pumps from 11 kW and up suspended in the pipes


Installation

Pump type PN 16 PN 25 P2 [kW]

60 Hz
TP, TPE 65-480/2 ● - 11 - ●
TP, TPE 65-540/2 ● - 15 - ●
TP, TPE 65-630/2 ● - 18.5 - ●
TP, TPE 65-740/2 ● - 22 - ●
TP, TPE 80-330/2 ● - 11 - ●
TP, TPE 80-400/2 ● - 15 - ●
TP, TPE 80-480/2 ● - 18.5 - ●
TP, TPE 80-530/2 ● - 22 - ●
TP, TPE 100-300/2 ● - 11 - ●
TP, TPE 100-370/2 ● - 15 - ●
TP, TPE 100-350/2 ● - 18.5 - ●
TP, TPE 100-380/2 ● - 22 - ●
TP, TPE 80-340/4 ● - 11 - ●
TP, TPE 80-410/4 ● - 15 - ●
TP, TPE 80-460/4 ● - 18.5 - ●
TP 80-510/4 ● - 22 - ●
TP, TPE 100-240/4 ● ● 11 ● ●
TP, TPE 100-260/4 ● - 11 - ●
TP, TPE 100-290/4 ● ● 15 ● ●
TP, TPE 100-340/4 ● ● 18.5 ● ●
TP 100-350/4 ● - 22 - ●
TP 100-390/4 ● ● 22 ● ●
TP 100-470/4 - ● 30 ● -
TP 100-560/4 - ● 37 ● -
TP, TPE 125-200/4 ● - 11 - ●
TP, TPE 125-230/4 ● - 15 - ●
TP, TPE 125-220/4 - ● 15 - ●
TP, TPE 125-280/4 ● ● 18.5 - ●
TP 125-340/4 ● ● 22 - ●
TP 125-365/4 - ● 30 ● -
TP 125-420/4 - ● 30 ● -
TP 125-480/4 - ● 37 ● -
TP 125-550/4 - ● 45 ● -
TP 125-580/4 - ● 55 ● -
TP, TPE 150-180/4 ● ● 15 - ●
TP, TPE 150-210/4 ● ● 18.5 - ●
TP 150-240/4 ● ● 22 - ●
TP 150-300/4 - ● 30 ● -
TP 150-340/4 - ● 37 ● -
TP 150-360/4 - ● 30 ● -
TP 150-400/4 - ● 37 ● -
TP 150-440/4 - ● 45 ● -
TP 150-480/4 - ● 55 ● -
TP 150-610/4 - ● 75 ● -
TP 150-810/4 - ● 110 ● -
TP 150-960/4 - ● 132 ● -
TP 200-250/4 - ● 30 ● -
TP 200-400/4 - ● 75 ● -
TP 200-430/4 - ● 55 ● -
TP 300-230/4 - ● 45 ● -
TP 300-270/4 - ● 55 ● -
TP 300-360/4 - ● 75 ● -
TP 300-370/4 - ● 90 ● -
TP 300-440/4 - ● 110 ● -
TP 300-550/4 - ● 132 ● -
TP 300-630/4 - ● 160 ● -
TP 300-640/4 - ● 200 ● -
TP 300-750/4 - ● 250 ● -
TP 350-400/4 - ● 132 ● -
TP 350-450/4 - ● 160 ● -
TP 350-540/4 - ● 200 ● -
TP 350-680/4 - ● 250 ● -

106
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
19
In installations where the pump is suspended directly For further information about identification of TP Series

Installation
in the pipes, the pump can support the pipe length L on 300 models, see pages 24 to 26.
both sides of the pump. L is less than 3 x DN. See fig. If the liquid temperature falls below the ambient
79. In installations where the pump is suspended temperature or if the pump is installed outside,
directly in the pipes, the pump must be lifted and held condensation may form in the motor during inactivity.
in correct position by means of ropes or similar until In this case, the drain hole in the motor flange must be
both pump flanges are completely fastened to the pipe open and point downwards. See fig. 82.
flanges.
Vertical pipe

L Horizontal pipe

TM00 9831 3202


TM06 3518 0615
L

Fig. 82 Drain hole


Fig. 79 Pump suspended directly in the pipes
If twin-head pumps are used for pumping liquids with a
When installing a twin-head pump in a horizontal pipe temperature below 0 °C / 32 °F, condensed water may
and with horizontal shaft, fit the upper pump housing freeze and cause the coupling to get stuck. You can
with an automatic vent. remedy the problem by installing heating elements.
Whenever possible, install pumps with motors smaller
than 11 kW with horizontal motor shaft. See fig. 80.
Cooling
To ensure sufficient cooling of motor and electronics,
TM03 8127 0507

observe the following:


• Place the pump in such a way that sufficient cooling
is ensured.
• Keep the motor cooling fins, holes in fan cover and
Fig. 80 Twin-head pumps with automatic vent fan blades clean.
• Make sure the frequency for the motor is at least 6
Twin-head pump housings have two Rp 1/4 tappings, Hz, 12 % of maximum speed. The shaft seal may
TP Series 200, TPE2 D, TPE3 D, or four Rp 1/8 generate noise at speeds below 25 % of maximum
tappings, TP Series 300 for mounting of automatic speed.
vents.
TM02 7533 3703

Fig. 81 Tappings for mounting of automatic vents in TP


Series 200,TPE2 D, TPE3 D and TP Series 300

107
19 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Condensation cover Concrete foundation


Installation

When installing the pumps outdoors, provide the motor Install the pump on a plane and rigid concrete
with a suitable cover to protect the pump and motor foundation. This is the optimum solution for vibration
against the direct effects of the elements. dampening. As a rule of thumb, the weight of a
When mounting the condensation cover on top of the concrete foundation must be 1.5 times the pump
motor, make sure to leave enough space for the air to weight.
cool the motor. Recommended concrete foundations for TP, TPD
Series 300 pumps
For TP Series 300 pumps with weights of 150 kg or
more, we recommend that you mount the pump on a
concrete foundation with the dimensions stated in the
table below. The same recommendation applies to

TM02 8514 0304


TPD Series 300 pumps with weights of 300 kg or more.

Fig. 83 Motors with condensation cover

Elimination of noise and vibrations

TM03 9190 3507


In order to achieve optimum operation and minimum
noise and vibration, consider vibration dampening of
the pump. Generally, always consider this for pumps
with motors of 11 kW and up, but for motors of 90 kW
and up as well as the pumps stated in the table below,
Fig. 85 Foundation for TP, TPD Series 300 pumps
vibration dampening is mandatory. Smaller motor
sizes, however, may also cause undesirable noise and
Concrete foundation dimensions
vibration. Pump mass
[kg] X (Height) Y (Length) Z (Width)
Frequency [mm] [mm] [mm]
Pump type
[Hz]
150 280 565 565
TP 200-280/4 60 200 310 620 620
TP 200-320/4 60 250 330 670 670
TP 200-360/4 60 300 360 710 710
TP 200-390/4 60 350 375 750 750
400 390 780 780
Noise and vibration are generated by the revolutions of
450 410 810 810
the motor and pump and by the flow in pipes and
500 420 840 840
fittings. The effect on the environment is subjective 550 440 870 870
and depends on correct installation and the state of the 600 450 900 900
remaining system. 650 460 920 920
Elimination of noise and vibrations is best achieved by 700 470 940 940
means of a concrete foundation, vibration dampers 750 480 970 970
and expansion joints. 800 490 990 990
850 500 1010 1010
900 510 1030 1030
≤ DN 200
950 520 1050 1050
1000 530 1060 1060
Expansion joint 1050 540 1080 1080
Concrete foundation 1100 550 1100 1100
1150 560 1100 1100
1200 560 1130 1130
1250 570 1150 1150
TM02 4993 2102

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

1300 580 1160 1160


•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•• • • • • ••••••••••••••••••••••
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••••••••••••••••••••••
•••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
••••••••••••••••••••
••••••••••••••••••••• ••••••••••••••••••••
•••••••••••••••••••••
•••••••••••••••••••• ••••••••••••••••••••

1350 590 1180 1180


1400 600 1190 1190
Vibration dampers 1450 600 1200 1200
1500 610 1220 1220
Fig. 84 Foundation of TP pump
1550 620 1230 1230
1600 620 1250 1250
1650 630 1250 1250
1700 635 1270 1270

108
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
19
Expansion joints

Installation
Concrete foundation dimensions
Pump mass
[kg] X (Height) Y (Length) Z (Width) Expansion joints do the following:
[mm] [mm] [mm] • absorb expansions or contractions in the pipes
800 450 1400 800 caused by changing liquid temperature.
1000 450 1400 1000
• reduce mechanical strains in connection with
1200 450 1400 1200
pressure surges in the pipes.
1400 500 1600 1200
1600 500 1600 1350 • isolate mechanical structure-borne noise in the
1800 500 1600 1500 pipes. Only rubber bellows expansion joints.
2000 550 1600 1600 Note: Do not install expansion joints to compensate for
2200 DN 300 / 550 1700 1700 inaccuracies in the pipes such as centre displacement
2400 DN 350 / 550 1800 1800
DN 400
of flanges.
2600 600 1800 1800
3000 600 2000 2000 Fit expansion joints at a distance of minimum 1 to 1.5
3400 680 2000 2000 times the nominal flange diameter away from the pump
3800 760 2000 2000 on the inlet as well as on the outlet side. This prevents
4200 840 2000 2000 the development of turbulence in the expansion joints,
4600 920 2000 2000 resulting in better suction conditions and a minimum
5000 1000 2000 2000 pressure loss on the outlet side. At high water
5400 1080 2000 2000 velocities, greater than 5 m/s, we recommend that you
Vibration dampers install larger expansion joints corresponding to the
To prevent the transmission of vibrations to buildings, pipes. See fig. 86.
we recommend that you isolate the pump foundation Expansion joints
from building parts by means of vibration dampers.
The selection of the right vibration damper requires the
following data:
• Forces transmitted through the damper.
• Motor speed considering speed control, if any.
• Required dampening in %. The suggested value is

TM04 9629 4810


70 %.
The right damper varies from installation to installation,
and a wrong damper may increase the vibration level.
Vibration dampers must therefore be sized by the
supplier.
Fig. 86 TP pump installed with larger expansion joints
If you install the pump on a foundation with vibration
dampers, always fit expansion joints on the pump The illustration below shows examples of rubber
flanges. This is important to prevent the pump from bellows expansion joints with or without limit rods.
"hanging" in the flanges.

TM02 4979 1902 - TM02 4981 1902

Fig. 87 Examples of rubber bellows expansion joints

109
19 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

You can use expansion joints with limit rods to reduce Electrical installation
Installation

the effects of the expansion or contraction forces on


the pipes. We always recommend expansion joints Mains-operated motors
with limit rods for flanges larger than DN 100.
The operating voltage and frequency are marked on
Anchor the pipes in such a way that they do not stress
the pump nameplate. Make sure that the motor is
the expansion joints and the pump. Follow the
suitable for the power supply on which it will be used.
supplier's instructions and pass them on to advisers or
pipe installers. Single-phase standard motors incorporate a thermal
switch and require no additional motor protection.
The illustration below shows an example of a metal
bellows expansion joint with limit rods. Three-phase motors must be connected to a motor
starter.
Motors of 3 kW and up incorporate thermistors, PTC.
The thermistors are designed according to DIN 44082.
The electrical connection must be carried out as
shown in the diagram inside the terminal box cover.

TM02 4980 1902


The motors of twin-head pumps are to be connected
separately.
Frequency converter operation
Fig. 88 Example of metal expansion joint Motors types Siemens, MG 71 and MG 80 for supply
voltages up to and including 440 V must be protected
Due to the risk of rupture of the rubber bellows, metal against voltage peaks higher than 650 V between the
bellows expansion joints may be preferred at supply terminals. See the motor nameplate.
temperatures above 100 °C combined with high
Grundfos motors:
pressure.
You can connect all three-phase Grundfos motors from
Terminal box positions frame size 90 and up to a frequency converter.
TP single-head pumps The connection of a frequency converter often has the
As standard, the terminal boxes of TP and TPE, TPE2, effect that the motor insulation system is loaded more
TPE3 pumps are mounted in 9 o'clock position. The and that the motor is more noisy than during normal
possible terminal box positions are shown below. operation. In addition, large motors are loaded by
bearing currents caused by the frequency converter.
In the case of frequency converter operation, consider
the following:
In 2-pole motors from 45 kW, 4-pole motors from 37
kW and 6-pole motors from 30 kW, one of the motor
bearings must be electrically isolated to prevent
TM03 0565 2005

damaging currents from passing through the motor


3 Stellung
o'clock 3 6 Stellung
o'clock6 9Stellung
o'clock9 12 o'clock
Stellung 12 bearings.
position position position position In the case of noise-critical applications, reduce the
Standard
motor noise by fitting a dU/dt filter between the motor
Fig. 89 Possible terminal box positions and the frequency converter. In particularly
noise-critical applications, we recommend that you fit a
Note: Due to the motor construction, the terminal
sinusoidal filter.
boxes of some TP pumps with motor sizes above 250
kW are mounted in 10:30 position. The length of the cable between the motor and
frequency converter affects the motor load. Therefore
TPD twin-head pumps check that the cable length meets the specifications
As standard, the terminal boxes of all TPD pumps are laid down by the frequency converter supplier.
mounted in 12 o'clock position. See fig. 89. For supply voltages between 500 and 690 V, fit either a
On TPE2 D, TPE3 D pumps the terminal box is dU/dt filter to reduce voltage peaks or use a motor with
installed in a position different from 12 o'clock. reinforced insulation.
For supply voltages of 690 V, use a motor with
reinforced insulation, and fit a dU/dt filter.
For other motor makes than Grundfos, contact
Grundfos or the motor manufacturer.

110
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20

20. MGE motors

MGE motors
Motors for TPE2, TPE2 D, TPE3, Inputs and outputs
TPE3 D pumps and 2.2 - 11 kW Earth reference, GND
2-pole motors and 1.5 - 7.5 kW All voltages refer to GND.
All currents return to GND.
4-pole motors fitted on TPE Series
Absolute maximum voltage and current limits
1000 pumps
Exceeding the following electrical limits may result in
Single-phase supply voltage severely reduced operating reliability and motor life:
Relay 1:
1 x 200-240 V - 10 %/+ 10 %, 50/60 Hz, PE.
Maximum contact load: 250 VAC, 2 A or 30 VDC, 2 A.
Recommended fuse size Relay 2:
Motor size Min. Max. Maximum contact load: 30 VDC, 2 A.
[kW] [A] [A] GENI terminals: -5.5 to 9.0 VDC or less than 25
0.25 - 0.75 6 10 mADC.
1.1 - 1.5 10 16
Other input or output terminals: -0.5 to 26 VDC or less
You can use standard as well as quick-blow or than 15 mADC.
slow-blow fuses.
Digital inputs, DI
Leakage current Internal pull-up current greater than 10 mA at Vi equal
Earth leakage current less than 3.5 mA, AC. to 0 VDC.
Earth leakage current less than 10 mA, DC supply. Internal pull-up to 5 VDC (currentless for Vi greater
The leakage currents are measured in accordance with than 5 VDC).
EN 61800-5-1:2007. Certain low logic level: Vi less than 1.5 VDC.
Certain high logic level: Vi greater than 3.0 VDC.
Three-phase supply voltage Hysteresis: No.
3 x 380-500 V - 10 %/+ 10 %, 50/60 Hz, PE. Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Recommended fuse size Maximum cable length: 500 m.

Motor size Min. Max. Open-collector digital outputs, OC


[kW] [A] [A] Current sinking capability: 75 mADC, no current
1.5 6 10 sourcing.
2.2 6 16
Load types: Resistive or/and inductive.
3 10 16
4 13 16 Low-state output voltage at 75 mADC: Maximum 1.2
5.5 16 32 VDC.
7.5 20 32 Low-state output voltage at 10 mADC: Maximum 0.6
11 32 32 VDC.
You can use standard as well as quick-blow or Overcurrent protection: Yes.
slow-blow fuses. Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Leakage current, AC Maximum cable length: 500 m.

Speed Power Mains voltage Leakage current


[min-1] [kW] [V] [mA]
≤ 400 < 3.5
0.25 - 1.5
> 400 <5
1400-2000 ≤ 400 < 3.5
2.2 - 4
1450-2200 > 400 < 3.5
≤ 400 < 3.5
5.5 - 7.5
> 400 <5
≤ 400 < 3.5
0.25 - 2.2
> 400 <5
≤ 400 < 3.5
2900-4000 3 - 5.5
> 400 < 3.5
≤ 400 < 3.5
7.5 - 11
> 400 <5

The leakage currents are measured without any load


on the shaft and in accordance with EN
61800-5-1:2007.

111
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Analog inputs, AI Pt100/1000 inputs, PT


MGE motors

Voltage signal ranges: Temperature range:


• 0.5 - 3.5 VDC, AL AU. • Minimum -30 °C, 88 Ω / 882 Ω.
• 0-5 VDC, AU. • Maximum 180 °C, 168 Ω / 1685 Ω.
• 0-10 VDC, AU. Measurement tolerance: ± 1.5 °C.
Voltage signal: Ri greater than 100 kΩ at 25 °C. Measurement resolution: less than 0.3 °C.
Leak currents may occur at high operating Automatic range detection, Pt100 or Pt1000: Yes.
temperatures. Keep the source impedance low. Sensor fault alarm: Yes.
Current signal ranges: Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
• 0-20 mADC, AU. Use Pt100 for short wires.
• 4-20 mADC, AL AU. Use Pt1000 for long wires.
Current signal: Ri equal to 292 Ω.
LiqTec sensor inputs*
Current overload protection: Yes. Change to voltage
Use Grundfos LiqTec sensor only.
signal.
Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Measurement tolerance: - 0/+ 3 % of full scale
(maximum-point coverage). Grundfos Digital Sensor input and output, GDS
Screened cable: 0.5 - 1.5 mm2, 28-16 AWG. Use Grundfos Digital Sensor only*.
Maximum cable length: 500 m, excl. potentiometer. * Only applicable for TPE3, TPE3 D pumps.
Potentiometer connected to +5 V, GND, any AI: Power supplies
Use maximum 10 kΩ.
+5 V:
Maximum cable length: 100 m.
• Output voltage: 5 VDC - 5 %/+ 5 %.
Analog output, AO
• Maximum current: 50 mADC, sourcing only.
Current sourcing capability only. • Overload protection: Yes.
Voltage signal:
24 V:
• Range: 0-10 VDC.
• Output voltage: 24 VDC - 5 %/+ 5 %.
• Minimum load between AO and GND: 1 kΩ.
• Maximum current: 60 mADC, sourcing only.
• Short-circuit protection: Yes.
• Overload protection: Yes.
Current signal:
• Ranges: 0-20 and 4-20 mADC. Digital outputs, relays
• Maximum load between AO and GND: 500 Ω. Potential-free changeover contacts.
• Open-circuit protection: Yes. Minimum contact load when in use: 5 VDC, 10 mA.
Tolerance: - 0/+ 4 % of full scale (maximum-point Screened cable: 0.5 - 2.5 mm2, 28-12 AWG.
coverage). Maximum cable length: 500 m.
Screened cable: 0.5 - 1.5 mm2, 28-16 AWG. Bus input
Maximum cable length: 500 m.
Grundfos GENIbus protocol, RS-485.
Screened 3-core cable: 0.5 - 1.5 mm2, 28-16 AWG.
Maximum cable length: 500 m.

112
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20
EMC (electromagnetic compatibility) Cable entries

MGE motors
Standard used: EN 61800-3. TPE Series 1000
The table below shows the emission category of the
Number and size of cable entries
motor.
Motor 1400-2000
C1 fulfils the requirements for residential areas. [kW] 1450-2200
2900-4000
min-1
Note: When connected to a public network, 11 kW min-1
motors do not comply with the partial weighted 1.5 4 x M20 4 x M20
harmonic distortion (PWHD) requirements of EN 2.2 1 x M25 + 4 x M20 4 x M20
61000-3-12. If required by the distribution network 3.0 - 4.0 1 x M25 + 4 x M20 1 x M25 + 4 x M20
5.5 1 x M32 + 5 x M20 1 x M25 + 4 x M20
operator, compliance can be obtained in the following
7.5 - 11 1 x M32 + 5 x M20 1 x M32 + 5 x M20
way:
The impedance of the mains cables between the motor TPE2, TPE2 D, TPE3, TPE3 D
and the point of common coupling (PCC) must be Number and size of cable entries: 4 x M20.
equivalent to the impedance of a 50 m cable with a
cross-section of 0.5 mm. Sound pressure level
C3 fulfils the requirements for industrial areas. TPE Series 1000
Note: When the motors are installed in residential
areas, supplementary measures may be required as Maximum Sound pressure level
Motor speed stated Speed ISO 3743
the motors may cause radio interference. [dB(A)]
[kW] on nameplate [min-1]
[min-1] 3-phase motors
Emission category
Motor
2900-4000 min-1 1500 42
[kW] 1450-2000 min-1 2000
4000-5900 min-1 2000 47
1.5
0.25 C1 C1 3000 57
4000
0.37 C1 C1 4000 64
0.55 C1 C1 1500 48
2000
0.75 C1 C1 2000 55
2.2
1.1 C1 C1 3000 57
4000
1.5 C1 C1 4000 64
2.2 C1 C1 1500 48
2000
3 C1 C1 2000 55
3
4 C1 C1 3000 60
4000
5.5 C3/C1* C1 4000 69
7.5 C3/C1* C3/C1* 1500 48
2000
11 - C3/C1* 2000 55
4
3000 61
* 4000
C1, if equipped with an external Grundfos EMC filter. 4000 69
1500 58
Immunity: The motor fulfils the requirements for 2000
2000 61
industrial areas. 5.5
3000 61
4000
Contact Grundfos for further information. 4000 69
1500 58
2000
Enclosure class 7.5
2000 61
3000 66
Standard: IP55 (IEC 34-5). 4000
4000 73
Optional: IP66 (IEC 34-5). 3000 66
11 4000
4000 73
Insulation class
F (IEC 85).

Ambient temperature
During operation: -20 to 50 °C.
During storage and transportation: -30 to 60 °C.

Standby power consumption


5-10 W.

113
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

TPE2, TPE2 D, TPE3, TPE3 D Additional protection


MGE motors

Sound pressure level The residual-current circuit breaker must be marked


Pump size ISO 3743 with the following symbol:
[dB(A)]
TPE2/TPE3 32-80 55
TPE2/TPE3 32-120 60
TPE2/TPE3 32-150 65
TPE2/TPE3 32-180 66
TPE2/TPE3 32-200 66
The total leakage current of all the electrical equipment
TPE2/TPE3 40-80 52
TPE2/TPE3 40-120 59
in the installation must be taken into account. You find
TPE2/TPE3 40-150 60 the leakage current of the motor in Leakage current
TPE2/TPE3 40-180 63 and Leakage current, AC, see page 111.
TPE2/TPE3 40-200 65 This product can cause a direct current in the
TPE2/TPE3 40-240 66 protective-earth conductor.
TPE2/TPE3 50-60 48
TPE2/TPE3 50-80 56 Overvoltage and undervoltage protection
TPE2/TPE3 50-120 60 Overvoltage and undervoltage may occur in case of
TPE2/TPE3 50-150 60 unstable power supply or a faulty installation. The
TPE2/TPE3 50-180 63
motor is stopped if the voltage falls outside the
TPE2/TPE3 50-200 64
permissible voltage range. The motor restarts
TPE2/TPE3 50-240 66
TPE2/TPE3 65-60 44
automatically when the voltage is again within the
TPE2/TPE3 65-80 51 permissible voltage range. Therefore, no additional
TPE2/TPE3 65-120 59 protection relay is required.
TPE2/TPE3 65-150 62 Note: The motor is protected against transients from
TPE2/TPE3 65-180 62 the power supply according to EN 61800-3. In areas
TPE2/TPE3 65-200 62 with high lightning intensity, we recommend external
TPE2/TPE3 80-40 43
lightning protection.
TPE2/TPE3 80-120 53
TPE2/TPE3 80-150 62 Overload protection
TPE2/TPE3 80-180 64
If the upper load limit is exceeded, the motor
TPE2/TPE3 100-40 43
automatically compensates for this by reducing the
TPE2/TPE3 100-120 53
TPE2/TPE3 100-150 62
speed and stops if the overload condition persists.
TPE2/TPE3 100-180 64 The motor remains stopped for a set period. After this
period, the motor automatically attempts to restart. The
Motor protection overload protection prevents damage to the motor.
The motor requires no external motor protection. The Consequently, no additional motor protection is
motor incorporates thermal protection against slow required.
overloading and blocking. Overtemperature protection
The electronic unit has a built-in temperature sensor
as an additional protection. When the temperature
rises above a certain level, the motor automatically
compensates for this by reducing the speed and stops
if the temperature keeps rising. The motor remains
stopped for a set period. After this period, the motor
automatically attempts to restart.
Protection against phase unbalance
Three-phase motors must be connected to a power
supply with a quality corresponding to IEC 60146-1-1,
class C, to ensure correct motor operation at phase
unbalance. This also ensures long life of the
components.

114
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20
Maximum number of starts and stops Connection terminals

MGE motors
The number of starts and stops via the power supply The descriptions and terminal overviews in this section
must not exceed four times per hour. apply to both single-phase and three-phase motors.
When switched on via the power supply, the pump Connection terminals, advanced functional
starts after approximately 5 seconds. module, FM 300
If you want a higher number of starts and stops, use The advanced module has these connections:
the input for external start-stop when starting or • three analog inputs
stopping the pump. • one analog output
When you start the pump via an external on/off switch, • two dedicated digital inputs
the pump starts immediately.
• two configurable digital inputs or open-collector
Wiring diagrams outputs
• Input and output for Grundfos Digital Sensor
Single-phase supply:
Not applicable for TPE Series 1000 and TPE2,
RCD, TPE2 D pumps.
type B The factory-fitted differential-pressure sensor for
TPE3, TPE3 D pumps is connected to this input.

TM05 4034 1912


• two Pt100/1000 inputs
• two LiqTec sensor inputs
• two signal relay outputs
Fig. 90 Example of a mains-connected motor with mains • GENIbus connection.
switch, backup fuse and additional protection
See fig. 92.
Three-phase supply: Note: Digital input 1 is factory-set to be start-stop
input where open circuit results in stop. A jumper has
RCD,
type B been factory-fitted between terminals 2 and 6. Remove
L1
the jumper if digital input 1 is to be used as external
L1
start-stop or any other external function.
TM05 3942 1812

L2 L2
L3
• Inputs and outputs
L3
All inputs and outputs are internally separated from
PE
the mains-conducting parts by reinforced insulation
and galvanically separated from other circuits.
Fig. 91 Example of a mains-connected motor with mains All control terminals are supplied by protective
switch, backup fuse and additional protection extra-low voltage, PELV, thus ensuring protection
against electric shock.
• Signal relay outputs
– Signal relay 1:
LIVE:
You can connect supply voltages up to 250 VAC.
PELV:
The output is galvanically separated from other
circuits. Therefore, you can connect the supply
voltage or protective extra-low voltage to the
output as desired.
– Signal relay 2:
PELV:
The output is galvanically separated from other
circuits. Therefore, you can connect the supply
voltage or protective extra-low voltage to the
output as desired.
• Mains supply, terminals N, PE, L or L1, L2, L3, PE.

115
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
MGE motors

Terminal Type Function


NC Normally closed contact
Signal relay 1
C1 Common
LIVE or PELV
NO Normally open contact

NC Normally closed contact


Signal relay 2
C2 Common
PELV only
NO Normally open contact

18 GND Earth
Digital input/output,
configurable.
11 DI4/OC2
Open collector: Maximum
24 V resistive or inductive.
19 Pt100/1000 input 2 Pt100/1000 sensor input
NC 17 Pt100/1000 input 1 Pt100/1000 sensor input
C1 Analog output:
NO 12 AO 0-20 mA / 4-20 mA
0-10 V
NC
9 GND Earth
C2
Analog input:
NO
14 AI3 0-20 mA / 4-20 mA
OC DI
18 GND 0-10 V
+24 V*
11 DI4/OC2 1 DI2 Digital input, configurable
19 Pt100/1000
LiqTec sensor input
17 Pt100/1000 21 LiqTec sensor input 1
White conductor
12 AO
Earth
+24 V* +24 V*/5 V* +5 V* 9 GND 20 GND
+24 V* + +
Brown and black conductors
14 AI3
LiqTec sensor input
1 DI2 22 LiqTec sensor input 2
Blue conductor
21 LiqTec
20 GND Digital input/output,
configurable.
22 LiqTec 10 DI3/OC1
OC DI Open collector: Maximum
+24 V* GND
10 DI3/OC1 24 V resistive or inductive.
4 AI1 Analog input:
+24 V* +24 V* +24 V*/5 V* 2 DI1 4 AI1 0-20 mA / 4-20 mA
+ +
5 +5 V
0.5 - 3.5 V / 0-5 V / 0-10 V
6 GND 2 DI1 Digital input, configurable
A GENIbus A Supply to potentiometer and
5 +5 V
Y GENIbus Y
sensor
B GENIbus B
6 GND Earth
A GENIbus, A GENIbus, A (+)
3 GND
15
Y GENIbus, Y GENIbus, GND
+24 V
8
B GENIbus, B GENIbus, B (-)
+24 V
26 +5 V 3 GND Earth
TM05 3509 3512

23 GND
15 +24 V Supply
25 GDS TX
+24 V* +24 V* +24 V*/5 V*
+ + 8 +24 V Supply
24 GDS RX
Supply to potentiometer and
+5 V* 7 26 +5 V
AI2 sensor
23 GND Earth
* If an external supply source is used, there must be a connection to Grundfos Digital Sensor
GND. 25 GDS TX
output
Grundfos Digital Sensor
Fig. 92 Connection terminals, FM 300 (option) 24 GDS RX
input
Analog input:
7 AI2 0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V / 0-10 V

116
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20
MGE motors, 11 to 18.5 kW, 4-pole, Setpoint signals

MGE motors
• Potentiometer
and 15 to 22 kW, 2-pole 0-10 VDC, 10 kΩ via internal voltage supply.
Grundfos MGE 100, MGE 112, MGE 132, MGE 160 Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
and MGE 180 motors offer these features: Maximum cable length: 100 m.
• Three-phase mains connection. • Voltage signal
• Three-phase, asynchronous squirrel-cage induction 0-10 VDC, Ri greater than 50 kΩ.
motors designed to current IEC, DIN and VDE Tolerance: + 0 %/- 3 % at maximum voltage signal.
guidelines and standards. The motors incorporate a Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
frequency converter and PI controller. Maximum cable length: 500 m.
• Used for continuously variable speed control of • Current signal
Grundfos E-pumps available in power sizes 11 to DC 0-20 mA / 4-20 mA, Ri equal to 175 Ω.
18.5 kW, 4-pole, and 15 to 22 kW, 2-pole. Tolerance: + 0 %/- 3 % at maximum current signal.
Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Supply voltage Maximum cable length: 500 m.
3 x 380-480 V - 10 %/+ 10 %, 50/60 Hz, PE. Sensor signals
Backup fuse • Voltage signal
0-10 VDC, Ri greater than 50 kΩ via internal voltage
Motor size Maximum fuse supply.
[kW] [A]
Tolerance: + 0 %/- 3 % at maximum voltage signal.
11 26
Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
15 36
Maximum cable length: 500 m.
18.5 43
22 51 • Current signal
DC 0-20 mA / 4-20 mA, Ri = 175 Ω.
You can use standard as well as quick-blow or Tolerance: + 0 %/- 3 % at maximum current signal.
slow-blow fuses. Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Leakage current Maximum cable length: 500 m.
• Power supply to sensor
Motor size Leakage current
[kW] [mA]
+24 VDC, maximum 40 mA.
11-22 > 10 Signal output
The leakage currents are measured in accordance with • Potential-free changeover contact.
EN 61800-5-1. Maximum contact load: 250 VAC, 2 A.
Minimum contact load: 5 VDC, 10 mA.
Input/output Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Maximum cable length: 500 m.
Start/stop
Bus input
• External potential-free switch.
Voltage: 5 VDC. Grundfos GENIbus protocol, RS-485.
Current: less than 5 mA. Screened cable: 0.5 - 1.5 mm2, 28-16 AWG.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG. Maximum cable length: 500 m.
Digital input
• External potential-free switch.
Voltage: 5 VDC.
Current: less than 5 mA.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.

117
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

EMC, electromagnetic compatibility to EN Additional protection


MGE motors

61800-3 The residual-current circuit breaker must be marked


with the following symbol:
Motor
Emission/immunity
[kW]
11 Emission:
15 The motors are category C3, corresponding to CISPR11,
18.5 group 2, class A, and may be installed in industrial areas
(second environment).
22
If fitted with an external Grundfos EMC filter, the motors are
category C2, corresponding to CISPR11, group 1, class A,
The total leakage current of all the electrical equipment
and may be installed in residential areas (first in the installation must be taken into account. You find
environment). the leakage current of the motor in Leakage current
When the motors are installed in residential areas, and Leakage current, AC, see page 111.
Note: supplementary measures may be required as the
motors may cause radio interference. This product can cause a direct current in the
Immunity: protective-earth conductor.
The motors fulfil the requirements for both the first and
second environment. Overvoltage and undervoltage protection
Overvoltage and undervoltage may occur in case of
For further information about EMC, see unstable power supply or a faulty installation. The
Electromagnetic compatibility and proper installation, motor is stopped if the voltage falls outside the
page 122. permissible voltage range. The motor restarts
automatically when the voltage is again within the
Enclosure class permissible voltage range. Therefore, no additional
Standard: IP55 (IEC 34-5). protection relay is required.
Note: The motor is protected against transients from
Insulation class the power supply according to EN 61800-3. In areas
F (IEC 85). with high lightning intensity, we recommend external
lightning protection.
Ambient temperature Overload protection
During operation: -20 to +40 °C
If the upper load limit is exceeded, the motor
During storage/transport: -25 to +70 °C automatically compensates for this by reducing the
speed and stops if the overload condition persists.
Relative humidity The motor remains stopped for a set period. After this
Maximum 95 %. period, the motor automatically attempts to restart. The
overload protection prevents damage to the motor.
Sound pressure level Consequently, no additional motor protection is
required.
Speed stated on the Sound pressure
Motor
nameplate level Overtemperature protection
[kW]
[min-1] [dB(A)]
1400-1500 54
The electronic unit has a built-in temperature sensor
11 as an additional protection. When the temperature
1700-1800 59
1400-1500 54 rises above a certain level, the motor automatically
1700-1800 59 compensates for this by reducing the speed and stops
15
2800-3000 65 if the temperature keeps rising. The motor remains
3400-3600 70 stopped for a set period. After this period, the motor
1400-1500 65 automatically attempts to restart.
1700-1800 69
18.5 Protection against phase unbalance
2800-3000 69
3400-3600 74 Three-phase motors must be connected to a power
2800-3000 73 supply with a quality corresponding to IEC 60146-1-1,
22
3400-3600 78
class C, to ensure correct motor operation at phase
unbalance. This also ensures long life of the
Motor protection components.
The motor requires no external motor protection. The
motor incorporates thermal protection against slow
overloading and blocking.

118
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
20
Maximum number of starts and stops • Group 3: Mains supply (terminals L1, L2, L3).

MGE motors
A galvanically safe separation must fulfil the
The number of starts and stops via the power supply
requirements for reinforced insulation including
must not exceed four times per hour.
creepage distances and clearances specified in EN
When switched on via the power supply, the pump 61800-5-1.
starts after approximately 5 seconds.
If a higher number of starts and stops is desired, use

Group 2

Group 3
the input for external start-stop when starting or
stopping the pump.
When started via an external on/off switch, the pump
starts immediately.

Wiring diagram, 11-22 kW


3 x 380-480 V - 10 %/+ 10 %, 50/60 Hz
External switch
Max. 26/51 A
L1 L1
ELCB

TM00 9270 4696


L2 L2
L3 L3
PE

Fig. 93 Wiring diagram, three-phase MGE motors, 11-22 1: Digital input


kW 9: GND (frame)
8: +24 V
7: Sensor input
Other connections B: RS-485B
Y: Screen
Note: As a precaution, make sure that the wires to be

Group 1
A: RS-485A
connected to the connection groups are separated
from each other by reinforced insulation in their entire 6: GND (frame)
lengths. 5: +10 V

TM03 8608 2007


4: Setpoint input
Group 1: Inputs 3: GND (frame)
2: Start/stop
• Start or stop, terminals 2 and 3
• digital input, terminals 1 and 9
• setpoint input, terminals 4, 5 and 6 Fig. 94 Connection terminals
• sensor input, terminals 7 and 8
• GENIbus, terminals B, Y and A.
All inputs, group 1, are internally separated from the
mains-conducting parts by reinforced insulation and
galvanically separated from other circuits.
All control terminals are supplied by protective
extra-low voltage, PELV, thus ensuring protection
against electric shock.
• Group 2: Output (relay signal, terminals NC, C,
NO).
The output, group 2, is galvanically separated from
other circuits. Therefore, you can connect the
supply voltage or protective extra-low voltage to the
output as desired.

119
20 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Identification of functional module


MGE motors

You can identify the module in one of the following


ways:
Grundfos GO
Select the "Fitted modules" menu under "Status".
Pump display
If the pump is fitted with the advanced control panel,
select "Fitted modules" menu under "Status".
Motor nameplate
You can identify the fitted module on the motor
nameplate. See fig. 95.

VARIANT
ype :
Typ
Type P.C. : INPUT
Hp VARIANT
OUTPUT
PB :
:
Xxxxxxxxxxx

P.N. : Serial no : U in P
P2 : Hp
PB :
rpm FMFM :
E.P. Motor

DE : Env.Type
Env.Ty ype
p : TEFC ~ V n max: rpm:
NDE : SF : CL: f in : Hz Eff : HMI : Made in Hungary
Wgt
Wggt : g Tamb :
kg F PF: I SF Ampp: A I 1/1 : A HMI
HMI:
CIM : : DK - 8850 Bjerringbro, Denmark

CIM : TM06 1889 3314

Fig. 95 Identification of functional module

Variant Description
FM 200 Standard functional module
FM 300 Advanced functional module

120
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
21

21. Electromagnetic compatibility, EMC

Electromagnetic compatibility, EMC


Electromagnetic compatibility and E-pumps and electromagnetic
proper installation compatibility
All Grundfos E-pumps are CE- and C-tick-marked
General information indicating that the product is designed to meet the
EMC requirements defined by the European Union and
The growing use of electric or electronic controls and
Australia/New Zealand.
electronic equipment including PLCs and computers
within all business areas require these products to fulfil EMC and CE
the existing standards within electromagnetic
compatibility. Make sure that the equipment is
mounted properly. All E-pumps fulfil the EMC directive 2004/108/EC and
This section deals with these issues. are tested according to standard EN 61800-3. All
E-pumps are fitted with a radio-interference filter and
What is electromagnetic compatibility? varistors in the mains-supply input to protect the
electronics against voltage peaks and noise present in
Electromagnetic compatibility is the ability of an
the mains supply (immunity). At the same time, the
electric or electronic to function in a given
filter limits the amount of electrical noise which the
electromagnetic environment without disturbing the
E-pump emits to the mains supply network (emission).
surroundings and without being disturbed by other
All remaining inputs included in the electronic unit are
devices in the surroundings. Electromagnetic
also protected against peaks and noise which can
compatibility is normally split into emission and
damage or disturb the function of the unit.
immunity.
On top of that, the mechanical and electronic designs
Emission are made in such a way that the unit can operate
sufficiently under a certain level of radiated
Emission is defined as the electric or electromagnetic electromagnetic disturbance.
noise emitted by a device during operation and which
The limits which the E-pumps are tested against are
can reduce the function of other devices or disturb
listed in standard EN 61800-3.
various radio communications, including radio or TV.

Immunity Where to install E-pumps?


You can use all E-pumps with MGE motors in both
Immunity is the ability of a device to function in spite of
residential areas (first environment) and industrial
the presence of electric or electromagnetic noise, such
areas (second environment) within certain limitations.
as sparking noise from contactors or high-frequency
fields from various transmitters or mobile phones.

121
21 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

What is meant by the first and the second


Electromagnetic compatibility, EMC

environment?
The first environment, residential areas, includes
establishments directly connected to a low-voltage
power supply network which supplies domestic
buildings.
The second environment, industrial areas, includes
establishments which are not connected to a
low-voltage network that supplies domestic buildings.
The level of electromagnetic disturbance can be much
higher than in the first environment.
EMC and C-tick

All E-pumps marked with the C-tick logo fulfil the


requirements for EMC in Australia and New Zealand.
The C-tick approval is based on the EN standards, and
the units are therefore tested according to the
European standard EN 61800-3.
Only E-pumps with MGE motors are marked with
C-tick.
The C-tick only covers emission.

Electromagnetic compatibility and proper


installation
With the CE and C-tick marks, the E-pumps live up to
and have been tested to meet specific EMC
requirements. This, however, does not mean that
E-pumps are immune to all the sources of noise to
which they can be exposed in practice. In some
installations, the impact may exceed the level to which
the product is designed and tested.
Furthermore, unproblematic operation in a noisy
environment presupposes that the installation of the
E-pump is made properly.
Below you will find a description of a correct E-pump
installation.

Connection of mains supply in MGE


Practice shows that large cable loops are often made
inside the terminal box to get some "spare cable". Of
course, this can be useful. However, with regard to
electromagnetic compatibility, it is a poor solution as
these cable loops will function as antennas inside the
terminal box.
To avoid problems with electromagnetic compatibility,
the mains supply cable and its individual conductors in
the terminal box of the E-pump must be as short as
possible. If required, you can establish a spare cable
outside the E-pump.

122
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
22

22. Flanges for TP pumps

Flanges for TP pumps


Flange dimensions
PN 6 and PN 10 flanges

EN 1092-2 PN 6 (0.6 MPa) EN 1092-2 PN 10 (1.0 MPa)

D1 Nominal diameter (DN) Nominal diameter (DN)


S

32 40 50 65 80 100 32 40 50 65 80 100 125 150 200 250

D1 32 40 50 65 80 100 32 40 50 65 80 100 125 150 200 250


TM02 7720 3803

D2 90 100 110 130 150 170 100 110 125 145 160 180 210 240 295 350

D3 120 130 140 160 190 210 140 150 165 185 200 220 250 285 340 395
D2
D3 S 4 x 14 4 x 14 4 x 14 4 x 14 4 x 19 4 x 19 4 x 19 4 x 19 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 8 x 23 12 x 23

PN 16 and PN 25 flanges

EN 1092-2 PN 16 (1.6 MPa) EN 1092-2 PN 25 (2.5 MPa)


D1 Nominal diameter (DN) Nominal diameter (DN)
S

32 40 50 65 80 100 125 150 200 100 125 150 200 250 300

D1 32 40 50 65 80 100 125 150 200 100 125 150 200 250 300
TM02 7720 3803

D2 100 110 125 145 160 180 210 240 295 190 220 250 310 370 430

D2 D3 140 150 165 185 200 220 250 285 340 235 270 300 360 425 485
D3 S 4 x 19 4 x 19 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 12 x 23 8 x 23 8 x 28 8 x 28 12 x 28 12 x 31 16 x 31

123
23 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

23. Curve charts


Curve charts

How to read the curve charts


+
>P@


 7373( Pump type and frequency
+]
 


 QH curve for the individual single-head pump.
 The bold curve indicates the recommended
 performance range.




 





       4>PñK@
3
>N:@
 


 The power curve indicates pump input power [P2].

 
 
 

 

       4>PñK@
136+
>P@



  The NPSH (3 %) curve shows the maximum net




positive suction head (NPSH) required to ensure
  that the pump head is not reduced by more than
 3 %. The available system pressure at the pump
 inlet must be according to the NPSH (3 %) curve.



       4>PñK@
(WD
>@


 

The eta curve shows the pump efficiency.
  

 
 




       4>PñK@
TM02 5040 2115

    4>OV@

      Y>PV@

124
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
23
Curve conditions

Curve charts
The guidelines below apply to the curves shown on the
following pages:
• Tolerances to ISO 9906:2012 Grade 3B.
• The curves apply to the performance of
single-head, three-phase pumps. For other pump
versions, please see the exact curves in Grundfos
Product Center. See page 224. For other pump
versions, the performance may differ for the
following reasons:
– The valve in twin-head pumps may cause losses.
– Note: Grundfos does not recommend continuous
parallel operation of twin-head pumps, except
TPE2 D, TPE3 D due to the increased flow in the
pump. An excessive flow results in noisy
operation, increased wear of the impeller due to
cavitation, etc.
• QH curves of the individual single-head pumps are
shown with expected speed of a three-phase
mains-operated motor. For further information, see
the tables of technical data on the following pages.
• Curves of TPE Series 1000 pumps are shown as
maximum curves (100 % curves) only. Please refer
to Grundfos Product Center for the exact curves.
See page 224.
• Measurements have been made with airless water
at a temperature of 20 °C.
• The curves apply to a kinematic viscosity of  equal
to 1 mm2/s (1 cSt).
• Due to the risk of overheating, the pump must not
run constantly below the minimum flow rate
indicated by the bold curves.
• If the pumped liquid density and/or viscosity are
higher than those of water, it may be necessary to
use a motor with a higher performance.

125
24
DN 32
PN 6, 10, 16
Performance curves and technical data

24. Performance curves and technical data


TPE2, TPE2 D, TPE3, TPE3 D, PN 6, 10, 16
TPE2, TPE2 D, TPE3, TPE3 D 32

+ +
>P@ >P@

 73( 
 73('

 73( 73('
  
 
 

 
 
 
 
  

  
  

 
            4>PñK@          4>PñK@
3

TM05 8191 3315


>N:@
            4>OV@


              Y>PV@




 
 


            4>PñK@
136+
>P@
 












            4>PñK@
(WD
>@








    



            4>PñK@
TM05 8171 2115

       4>OV@

         Y>PV@
Note: The dotted Q, H curves apply to TPE2 D, TPE3 D in parallel operation.

126
24
DN 32
PN 6, 10, 16

Performance curves and technical data


TM05 8182 2013 - TM05 8183 4514
Technical data

TPE2, TPE3 32 -80 -120 -150 -180 -200


TPE2, TPE3 ● ● ● ● ●
TPE2 D, TPE3 D ● ● ● ● ●
P2 1~/3~ kW 0.25 0.25 0.37 0.55 0.75
PN PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 32 32 32 32 32
AC 1~/3~ [mm] 122/122 122/122 122/122 122/122 122/122
AD 1~/3~ [mm] 158/158 158/158 158/158 158/158 158/158
AE 1~/3~ [mm] 106/134 106/134 106/134 106/134 106/134
AF 1~/3~ [mm] 106/134 106/134 106/134 106/134 106/134
P [mm] 165 165 165 165 165
B1 ★ [mm] 73/210 73/210 73/210 73/210 73/210
B2 ★ [mm] 73/209 73/209 73/209 73/209 73/209
B3 [mm] 260 260 260 260 260
1~ [mm] -/317 -/317 -/317 -/317 -/317
B4 ★
3~ [mm] -/337 -/337 -/337 -/337 -/337
C1 ★ [mm] -/263 -/263 -/263 -/263 -/263
C5 ★ [mm] -/50 -/50 -/50 -/50 -/50
C6 ★ [mm] -/97 -/97 -/97 -/97 -/97
C7 ★ [mm] -/90 -/90 -/90 -/90 -/90
C8 ★ [mm] -/130 -/130 -/130 -/130 -/130
L1 [mm] 220 220 220 220 220
H1 ★ [mm] 65/68 65/68 65/68 65/68 65/68
H2 [mm] 159 159 159 159 159
1~ [mm] 439/442 439/442 439/442 439/442 439/442
H3 ★
3~ [mm] 479/482 479/482 479/482 479/482 479/482
M M12 M12 M12 M12 M12

★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

127
24
DN 40
PN 6, 10, 16
Performance curves and technical data

TPE2, TPE2 D, TPE3, TPE3 D 40

+ +
>P@ >P@
  73(  73('


73(   73('
 
 
 
  
 
   
 
 
 
 
 
 
  
  

  
 
         4>PñK@            4>PñK@
3

TM05 8192 2115


>N:@
         4>OV@


        Y>PV@


 
 
 



         4>PñK@
136+
>P@ 
 






 





         4>PñK@
(WD
>@







 
 

   

         4>PñK@
TM05 8172 2115

     4>OV@

    Y>PV@

Note: The dotted Q, H curves apply to TPE2 D, TPE3 D in parallel operation.

128
24
DN 40
PN 6, 10, 16

Performance curves and technical data


TM05 8182 2013 - TM05 8183 4514
Technical data

TPE2, TPE3 40 -80 -120 -150 -180 -200 -240


TPE2, TPE3 ● ● ● ● ● ●
TPE2 D, TPE3 D ● ● ● ● ● ●
P2 1~/3~ kW 0.25 0.37 0.55 0.75 1.1 1.5
PN PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 40 40 40 40 40 40
AC 1~/3~ [mm] 122/122 122/122 122/122 122/122 122/122 122/122
AD 1~/3~ [mm] 158/158 158/158 158/158 158/158 158/158 158/158
AE 1~/3~ [mm] 106/134 106/134 106/134 106/134 106/134 106/134
AF 1~/3~ [mm] 106/134 106/134 106/134 106/134 106/134 106/134
P [mm] 165 165 165 165 165 165
B1 ★ [mm] 72/218 72/218 72/218 72/218 72/218 72/218
B2 ★ [mm] 82/220 82/220 82/220 82/220 82/220 82/220
B3 [mm] 260 260 260 260 260 260
1~ [mm] -/317 -/317 -/317 -/317 -/317 -/317
B4 ★
3~ [mm] -/337 -/337 -/337 -/337 -/337 -/337
C1 ★ [mm] -/260 -/260 -/260 -/260 -/260 -/260
C5 ★ [mm] -/75 -/75 -/75 -/75 -/75 -/75
C6 ★ [mm] -/58 -/58 -/58 -/58 -/58 -/58
C7 ★ [mm] -/155 -/155 -/155 -/155 -/155 -/155
C8 ★ [mm] -/130 -/130 -/130 -/130 -/130 -/130
L1 [mm] 250 250 250 250 250 250
H1 ★ [mm] 65/69 65/69 65/69 65/69 65/69 65/69
H2 [mm] 162 162 162 162 162 162
1~ [mm] 442/446 442/446 442/446 442/446 442/446 462/466
H3 ★
3~ [mm] 482/486 482/486 482/486 482/486 482/486 502/506
M M12 M12 M12 M12 M12 M12

★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

129
24
DN 50
PN 6, 10, 16
Performance curves and technical data

TPE2, TPE2 D, TPE3, TPE3 D 50

+ +
>P@ >P@


73(  73('
 73( 

73('
 

 
 

 


 
 
  
 


 


   

  


  
 
         4>PñK@         4>PñK@
3

TM05 8193 2115


>N:@
            4>OV@



           Y>PV@
 

 
 

 


         4>PñK@
136+
>P@



 





  


         4>PñK@
(WD
>@








 


     

         4>PñK@
TM05 8173 2115

       4>OV@

       Y>PV@

Note: The dotted Q, H curves apply to TPE2 D, TPE3 D in parallel operation.

130
24
DN 50
PN 6, 10, 16

Performance curves and technical data


TM05 8182 2013 - TM05 8183 4514
Technical data

TPE2, TPE3 50 -60 -80 -120 -150 -180 -200 -240


TPE2, TPE3 ● ● ● ● ● ● ●
TPE2 D, TPE3 D ● ● ● ● ● ● ●
P2 1~/3~ kW 0.37 0.37 0.55 0.75 1.1 1.5 2.2
PN PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 50 50 50 50 50 50 50
AC 1~/3~ [mm] 122/122 122/122 122/122 122/122 122/122 122/122 122/122
AD 1~/3~ [mm] 158/158 158/158 158/158 158/158 158/158 158/158 158/158
AE 1~/3~ [mm] 106/134 106/134 106/134 106/134 106/134 106/134 -/134
AF 1~/3~ [mm] 106/134 106/134 106/134 106/134 106/134 106/134 -/134
P [mm] 165 165 165 165 165 165 165
B1 ★ [mm] 75/223 75/223 75/223 75/223 75/223 75/223 75/223
B2 ★ [mm] 91/227 91/227 91/227 91/227 91/227 91/227 91/227
B3 [mm] 260 260 260 260 260 260 260
1~ [mm] -/317 -/317 -/317 -/317 -/317 -/317 -/317
B4 ★
3~ [mm] -/337 -/337 -/337 -/337 -/337 -/337 -/337
C1 ★ [mm] -/260 -/260 -/260 -/260 -/260 -/260 -/260
C5 ★ [mm] -/75 -/75 -/75 -/75 -/75 -/75 -/75
C6 ★ [mm] -/175 -/175 -/175 -/175 -/175 -/175 -/175
C7 ★ [mm] -/75 -/75 -/75 -/75 -/75 -/75 -/75
C8 ★ [mm] -/130 -/130 -/130 -/130 -/130 -/130 -/130
L1 [mm] 280 280 280 280 280 280 280
H1 ★ [mm] 72/75 72/75 72/75 72/75 72/75 72/75 72/75
H2 [mm] 162 162 162 162 162 162 162
1~ [mm] 449/451 449/451 449/451 449/451 449/451 469/471 -
H3 ★
3~ [mm] 489/491 489/491 489/491 489/491 489/491 509/511 509/511
M M12 M12 M12 M12 M12 M12 M12

★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

131
24
DN 65
PN 6, 10, 16
Performance curves and technical data

TPE2, TPE2 D, TPE3, TPE3 D 65

+ +
>P@ >P@
 73(  
73('


73(  
73('


 
   

 
 
  
 
 
 
  

   

 

 
           4>PñK@          4>PñK@
3

TM05 8194 2115


>N:@
            4>OV@


         Y>PV@






 


           4>PñK@
136+
>P@ 



 
 
 





           4>PñK@
(WD
>@







 



    

           4>PñK@
TM05 8174 2115

        4>OV@

     Y>PV@

Note: The dotted Q, H curves apply to TPE2 D, TPE3 D in parallel operation.

132
24
DN 65
PN 6, 10, 16

Performance curves and technical data


TM05 8182 2013 - TM05 8183 4514
Technical data

TPE2, TPE3 65 -60 -80 -120 -150 -180 -200


TPE2, TPE3 ● ● ● ● ● ●
TPE2 D, TPE3 D ● ● ● ● ● ●
P2 1~/3~ kW 0.37 0.55 0.75 1.1 1.5 2.2
PN PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 65 65 65 65 65 65
AC 1~/3~ [mm] 122/122 122/122 122/122 122/122 122/122 122/122
AD 1~/3~ [mm] 158/158 158/158 158/158 158/158 158/158 158/158
AE 1~/3~ [mm] 106/134 106/134 106/134 106/134 106/134 -/134
AF 1~/3~ [mm] 106/134 106/134 106/134 106/134 106/134 -/134
P [mm] 165 165 165 165 165 165
B1 ★ [mm] 81/228 81/228 81/228 81/228 81/228 81/228
B2 ★ [mm] 102/240 102/240 102/240 102/240 102/240 102/240
B3 [mm] 260 260 260 260 260 260
1~ [mm] -/317 -/317 -/317 -/317 -/317 -/317
B4 ★
3~ [mm] -/337 -/337 -/337 -/337 -/337 -/337
C1 ★ [mm] -/260 -/260 -/260 -/260 -/260 -/260
C5 ★ [mm] -/92 -/92 -/92 -/92 -/92 -/92
C6 ★ [mm] -/218 -/218 -/218 -/218 -/218 -/218
C7 ★ [mm] -/92 -/92 -/92 -/92 -/92 -/92
C8 ★ [mm] -/130 -/130 -/130 -/130 -/130 -/130
L1 [mm] 340 340 340 340 340 340
H1 ★ [mm] 74/78 74/78 74/78 74/78 74/78 74/78
H2 [mm] 169 169 169 169 169 169
1~ [mm] 458/462 458/462 458/462 458/462 478/482 -
H3 ★
3~ [mm] 498/502 498/502 498/502 498/502 518/522 518/522
M M12 M12 M12 M12 M12 M12

★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

133
24
DN 80
PN 6, 10, 16
Performance curves and technical data

TPE2, TPE2 D, TPE3, TPE3 D 80

+ +
>P@ >P@
  73( 
73('
73(  73('
  

  

 

 

  

  

  

 

 
        4>PñK@            4>PñK@
3

TM05 8195 2115


>N:@
         4>OV@

         Y>PV@











        4>PñK@
136+
>P@
 





 


        4>PñK@
(WD
>@









   



        4>PñK@
TM05 8175 2115

      4>OV@

     Y>PV@
Note: The dotted Q, H curves apply to TPE2 D, TPE3 D in parallel operation.

134
24
DN 80
PN 6, 10, 16

Performance curves and technical data


TM05 8182 2013 - TM05 8183 4514
Technical data

TPE2, TPE3 80 -40 -120 -150 -180


TPE2, TPE3 ● ● ● ●
TPE2 D, TPE3 D ● ● ● ●
P2 1~/3~ kW 0.25 1.1 1.5 2.2
PN PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 80 80 80 80
AC 1~/3~ [mm] 122/122 122/122 122/122 122/122
AD 1~/3~ [mm] 158/158 158/158 158/158 158/158
AE 1~/3~ [mm] 106/134 106/134 106/134 -/134
AF 1~/3~ [mm] 106/134 106/134 106/134 -/134
P [mm] 165 165 165 165
B1 ★ [mm] 97/244 97/244 97/244 97/244
B2 ★ [mm] 123/254 123/254 123/254 123/254
B3 [mm] 260 260 260 260
1~ [mm] -/317 -/317 -/317 -/317
B4 ★
3~ [mm] -/337 -/337 -/337 -/337
C1 ★ [mm] -/260 -/260 -/260 -/260
C5 ★ [mm] -/102 -/102 -/102 -/102
C6 ★ [mm] -/218 -/218 -/218 -/218
C7 ★ [mm] -/102 -/102 -/102 -/102
C8 ★ [mm] -/130 -/130 -/130 -/130
L1 [mm] 360 360 360 360
H1 ★ [mm] 94/97 94/97 94/97 94/97
H2 [mm] 176 176 176 176
1~ [mm] 485/488 485/488 505/508 -
H3 ★
3~ [mm] 525/528 525/528 545/548 545/548
M M12 M12 M12 M12

★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

135
24
DN 100
PN 6, 10, 16
Performance curves and technical data

TPE2, TPE2 D, TPE3, TPE3 D 100

+ +
>P@ >P@
  73( 73('

73( 73('
  

 
 
 

 

  

 


 

  
 
        4>PñK@            4>PñK@
3

TM05 8196 2115


>N:@
         4>OV@

 
        Y>PV@


 





        4>PñK@
136+
>P@


 

 




        4>PñK@
(WD
>@









 
  


        4>PñK@
TM05 8176 2115

      4>OV@

      Y>PV@


Note: The dotted Q, H curves apply to TPE2 D, TPE3 D in parallel operation.

136
24
DN 100
PN 6, 10, 16

Performance curves and technical data


TM05 8182 2013 - TM05 8183 4514
Technical data

TPE2, TPE3 100 -40 -120 -150 -180


TPE2, TPE3 ● ● ● ●
TPE2 D, TPE3 D ● ● ● ●
P2 1~/3~ kW 0.25 1.1 1.5 2.2
PN PN 6/10/16 PN 6/10/16 PN 6/10/16 PN 6/10/16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 100 100 100 100
AC 1~/3~ [mm] 122/122 122/122 122/122 122/122
AD 1~/3~ [mm] 158/158 158/158 158/158 158/158
AE 1~/3~ [mm] 106/134 106/134 106/134 -/134
AF 1~/3~ [mm] 106/134 106/134 106/134 -/134
P [mm] 165 165 165 165
B1 ★ [mm] 98/ 252 98/ 252 98/ 252 98/ 252
B2 ★ [mm] 125/ 265 125/ 265 125/ 265 125/ 265
B3 [mm] 270 270 270 270
1~ [mm] -/322 -/322 -/322 -/322
B4 ★
3~ [mm] -/342 -/342 -/342 -/342
C1 ★ [mm] -/270 -/270 -/270 -/270
C5 ★ [mm] -/147 -/147 -/147 -/147
C6 ★ [mm] -/243 -/243 -/243 -/243
C7 ★ [mm] -/147 -/147 -/147 -/147
C8 ★ [mm] -/135 -/135 -/135 -/135
L1 [mm] 450 450 450 450
H1 ★ [mm] 102/104 102/104 102/104 102/104
H2 [mm] 189 189 189 189
1~ [mm] 506/508 506/508 526/528 -
H3 ★
3~ [mm] 546/548 546/548 566/568 566/568
M M12 M12 M12 M12

★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

137
24
DN 32
2-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE, 2-pole, PN 6, 10, 16, 25


TP, TPD, TPE 32-XX/2
+ +
>P@ >P@


 73 
7373(
+]  +]
 

   

  
 

  


  

 
 

 

 
        4>PñK@          4>PñK@
3 3
>N:@ >N:@
 
 



 


  
 
 
  


 
        4>PñK@          4>PñK@
136+ 136+
>P@  >P@
  



 

 



 
 
        4>PñK@          4>PñK@
(WD (WD
>@ >@
 
  
 

 
   

  

  

 
        4>PñK@          4>PñK@
TM02 5034 2115

TM02 5035 2115

     4>OV@      4>OV@

     Y>PV@      Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

138
24
DN 32
2-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 32 -80/2 -160/2 -220/2 -260/2 -330/2 -300/2 -360/2 -450/2 -550/2 -680/2 -820/2
TPD - - - - - ● ● ● ● ● ●
TPE - - - - - ● ● ● ● ● ●
TPED - - - - - - - - - - -
Series 200 200 200 200 200 300 300 300 300 300 300
1~ TP - - - - - - - - - - -
3~ TP 71 71 80 90 90 90 100 112 132 132 160
IEC size
1~ TPE - - - - - - - - - - -
3~ TPE - - - - - 90 100 112 132 132 160
1~/3~ TP [kW] -/0.37 -/0.55 -/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11
P2
1~/3~ TPE [kW] - - - - - -/2.2 -/3 -/4 -/5.5 -/7.5 -/11
PN PN 6/10 PN 6/10 PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 32 32 32 32 32 32 32 32 32 32 32
1~/3~ TP [mm] -/142 -/142 -/142 -/142 -/178 -/178 -/198 -/220 -/220 -/260 -/314
AC
1~/3~ TPE [mm] - - - - - -/122 -/191 -/191 -/191 -/255 -/255
1~/3~ TP [mm] -/109 -/109 -/109 -/109 -/110 -/167 -/120 -/134 -/134 -/159 -/204
AD
1~/3~ TPE [mm] - - - - - -/158 -/201 -/201 -/201 -/237 -/237
AE 1~/3~ TPE [mm] - - - - - 132 146 146 146 237 237
AF 1~/3~ TPE [mm] - - - - - 132 146 146 146 237 237
P [mm] - - - - - 200 250 250 300 300 350
B1 ★ [mm] 75/- 75/- 102/- 102/- 102/- 144/321 144/321 144/321 144/321 144/321 144/321
B2 ★ [mm] 75/- 75/- 102/- 102/- 102/- 144/321 144/321 144/321 144/321 144/321 144/321
B3 [mm] - - - - - 355 355 355 355 355 355
C1 ★ [mm] 80/- 80/- 80/- 80/- 80/- 144/435 144/435 144/435 144/435 144/435 144/435
C5 ★ [mm] 110 110 140 140 140 220/46 220/46 220/46 220/46 220/46 220/46
C6 [mm] - - - - - 175 175 175 175 175 175
L1 [mm] 220 220 280 280 280 440 440 440 440 440 440
H1 [mm] 68 68 79 79 79 100 100 100 100 100 100
H2 [mm] 125 125 137 137 147 156 184 184 223 223 253
1~/3~ TP [mm] -/395 -/395 -/447 -/517 -/507 -/577 -/619 -/656 -/714 -/702 -/824
H3
1~/3~ TPE [mm] - - - - - -/530 -/618 -/618 -/712 -/736 -/759
H4 [mm] - - - - - - - - - - 35
M [mm] M12 M12 M12 M12 M12 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

139
24
DN 40
2-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 40-XX/2

+ +
>P@ >P@
  7373( 
7373(
  +]  +]

 
 


 

  
   
 
 

 

 
          4>PñK@            4>PñK@
3 3
>N:@ >N:@
 

 
   

 

 
 
 
  
  
 

 
          4>PñK@            4>PñK@
136+ 136+
>P@  >P@

 
 


 
 
 

 

 
 
 
 
          4>PñK@            4>PñK@
(WD (WD
>@ >@
  


 

 
 
  

   







 
          4>PñK@            4>PñK@
TM02 5036 2115

TM02 5037 2115

      4>OV@         4>OV@

     Y>PV@       Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

140
24
DN 40
2-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 40 -80/2 -160/2 -240/2 -270/2 -330/2 -390/2 -400/2 -460/2 -530/2 -690/2 -820/2 -920/2
TPD - - - - - - ● ● ● ● ● ●
TPE - - - - - - ● ● ● ● ● ●
TPED - - - - - - - - - - - -
Series 200 200 200 200 200 200 300 300 300 300 300 300
1~ TP - - - - - - - - - - - -
3~ TP 71 80 90 90 90 100 112 132 132 160 160 160
IEC size
1~ TPE - - - - - - - - - - - -
3~ TPE - - - - - - 112 132 132 160 160 160
1~/3~ TP [kW] -/0.55 -/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5
P2
1~/3~ TPE [kW] - - - - - - -/4 -/5.5 -/7.5 -/11 -/15 -/18.5
PN PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 40 40 40 40 40 40 40 40 40 40 40 40
1~/3~ TP [mm] -/142 -/142 -/142 -/178 -/178 -/178 -/220 -/220 -/260 -/314 -/314 -/314
AC
1~/3~ TPE [mm] - - - - - - -/191 -/191 -/255 -/255 -/314 -/314
1~/3~ TP [mm] -/109 -/109 -/109 -/110 -/110 -/110 -/134 -/134 -/159 -/204 -/204 -/204
AD
1~/3~ TPE [mm] - - - - - - -/201 -/201 -/237 -/237 -/308 -/308
AE 1~/3~ TPE [mm] - - - - - - 146 146 173 173 210 210
AF 1~/3~ TPE [mm] - - - - - - 146 146 173 173 210 210
P [mm] - - - - - - 250 300 300 350 350 350
B1 ★ [mm] 85/- 75/- 101/- 102/- 102/- 102/- 150/325 150/325 150/325 150/325 150/325 150/325
B2 ★ [mm] 75/- 75/- 101/- 102/- 102/- 102/- 147/325 147/325 147/325 147/325 147/325 147/325
B3 [mm] - - - - - - 355 355 355 355 355 355
C1 ★ [mm] 120/- 80/- 80/- 120/- 120/- 120/- 144/435 144/435 144/435 144/435 144/435 144/435
C5 ★ [mm] 125 125 125 160 160 160 220/108 220/108 220/108 220/108 220/108 220/108
C6 [mm] - - - - - - 175 175 175 175 175 175
L1 [mm] 250 250 250 320 320 320 440 440 440 440 440 440
H1 [mm] 67 67 68 68 68 68 110 110 110 110 110 110
H2 [mm] 132 139 144 150 150 160 184 223 223 253 253 253
1~/3~ TP [mm] -/390 -/437 -/513 -/500 -/540 -/564 -/666 -/724 -/724 -/834 -/834 -/878
H3
1~/3~ TPE [mm] - - - - - - -/628 -/722 -/746 -/769 -/834 -/878
H4 [mm] - - - - - - - - - 35 35 35
M [mm] M12 M12 M12 M12 M12 M12 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

141
24
DN 50
2-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 50-XX/2

+
>P@


 7373(
+]







 

 





         4>PñK@
3
>N:@

 

 

 



 


         4>PñK@
136+
>P@ 


 




         4>PñK@
(WD
>@
 



 
 

 


 


         4>PñK@
TM02 5038 2115

      4>OV@

      Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

142
24
DN 50
2-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 50 -80/2 -160/2 -240/2 -250/2 -300/2 -350/2 -410/2


TPD - - - ● ● ● ●
TPE - - - - ● ● ●
TPED - - - - - - -
Series 200 200 200 300 300 300 300
1~ TP - - - - - - -
3~ TP 71 90 90 90 100 112 132
IEC size
1~ TPE - - - - - - -
3~ TPE - - - - 100 112 132
1~/3~ TP [kW] -/0.55 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5
P2
1~/3~ TPE [kW] - - - - -/3 -/4 -/5.5
PN PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 50 50 50 50 50 50 50
1~/3~ TP [mm] -/142 -/142 -/175 -/178 -/198 -/220 -/220
AC
1~/3~ TPE [mm] - - - - -/191 -/191 -/191
1~/3~ TP [mm] -/109 -/109 -/110 -/110 -/120 -/134 -/134
AD
1~/3~ TPE [mm] - - - - -/201 -/201 -/201
AE 1~/3~ TPE [mm] - - - - 146 146 146
AF 1~/3~ TPE [mm] - - - - 146 146 146
P [mm] - - - 200 250 250 300
B1 ★ [mm] 95/- 100/- 100/- 117/252 117/252 133/290 133/290
B2 ★ [mm] 83/- 100/- 100/- 117/252 117/252 119/284 119/284
B3 [mm] - - - 270 270 320 320
C1 ★ [mm] 120/- 120/- 120/- 144/350 144/350 144/400 144/400
C5 ★ [mm] 140 140 140 170/60 170/60 170/52 170/52
C6 [mm] - - - 175 175 175 175
L1 [mm] 280 280 280 340 340 340 340
H1 [mm] 75 75 75 115 115 115 115
H2 [mm] 137 135 145 152 180 189 228
1~/3~ TP [mm] -/403 -/511 -/501 -/588 -/630 -/676 -/734
H3
1~/3~ TPE [mm] - - - - -/629 -/638 -/708
H4 [mm] - - - - - - -
M [mm] M12 M12 M12 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

143
24
DN 50
2-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 50-XX/2

+
>P@
 7373(

+]


 




 

 

 






         4>PñK@
3
>N:@
 




 

 
 


         4>PñK@
136+
>P@






 





         4>PñK@
(WD
>@
 



 
  





         4>PñK@
TM02 5039 2115

     4>OV@

      Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

144
24
DN 50
2-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 50 -430/2 -530/2 -640/2 -720/2 -790/2 -880/2 -1050/2


TPD ● ● ● ● ● ● ●
TPE ● ● ● ● ● ● -
TPED - - - - - - -
Series 300 300 300 300 300 300 300
1~ TP - - - - - - -
3~ TP 132 160 160 160 160 180 200
IEC size
1~ TPE - - - - - - -
3~ TPE 132 160 160 160 160 180 -
1~/3~ TP [kW] -/7.5 -/11 -/15 -/15 -/18.5 -/22 -/30
P2
1~/3~ TPE [kW] -/7.5 -/11 -/15 -/15 -/18.5 -/22 -
PN PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 50 50 50 50 50 50 50
1~/3~ TP [mm] -/260 -/314 -/314 -/314 -/314 -/314 -/396
AC
1~/3~ TPE [mm] -/255 -/255 -/314 -/314 -/314 -/314 -
1~/3~ TP [mm] -/159 -/204 -/204 -/204 -/204 -/204 -/315
AD
1~/3~ TPE [mm] -/237 -/237 -/308 -/308 -/308 -/308 -
AE 1~/3~ TPE [mm] 173 173 210 210 210 210 -
AF 1~/3~ TPE [mm] 173 173 210 210 210 210 -
P [mm] 300 350 350 350 350 350 400
B1 ★ [mm] 162/373 162/373 162/373 180/386 180/386 180/386 180/386
B2 ★ [mm] 162/373 162/373 162/373 164/379 164/379 164/379 164/379
B3 [mm] 420 420 420 420 420 420 420
C1 ★ [mm] 144/500 144/500 144/500 144/500 144/500 144/500 144/500
C5 ★ [mm] 220/123 220/123 220/123 220/123 220/123 220/123 220/123
C6 [mm] 175 175 175 175 175 175 175
L1 [mm] 440 440 440 440 440 440 440
H1 [mm] 115 115 115 115 115 115 115
H2 [mm] 228 257 257 264 264 264 264
1~/3~ TP [mm] -/734 -/843 -/843 -/850 -/894 -/894 -/942
H3
1~/3~ TPE [mm] -/731 -/778 -/843 -/850 -/894 -/920 -
H4 [mm] - 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

145
24
DN 65
2-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 65-XX/2

+
>P@


 7373(
+]
 









 





       4>PñK@
3
>N:@
 




 
 
 

 

       4>PñK@
136+
>P@



 


 





       4>PñK@
(WD
>@


 

  

 
 




       4>PñK@
TM02 5040 2115

    4>OV@

      Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

146
24
DN 65
2-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 65 -80/2 -160/2 -240/2 -200/2 -250/2 -340/2 -390/2


TPD - - - ● ● ● ●
TPE - - - ● ● ● ●
TPED - - - - - - -
Series 200 200 200 300 300 300 300
1~ TP - - - - - - -
3~ TP 90 90 90 100 112 132 132
IEC size
1~ TPE - - - - - - -
3~ TPE - - - 100 112 132 132
1~/3~ TP [kW] -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5
P2
1~/3~ TPE [kW] - - - -/3 -/4 -/5.5 -/7.5
PN PN 6/10 PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 65 65 65 65 65 65 65
1~/3~ TP [mm] -/142 -/175 -/175 -/198 -/220 -/220 -/260
AC
1~/3~ TPE [mm] - - - -/191 -/191 -/191 -/255
1~/3~ TP [mm] -/109 -/110 -/110 -/120 -/134 -/134 -/159
AD
1~/3~ TPE [mm] - - - -/201 -/201 -/201 -/237
AE 1~/3~ TPE [mm] - - - 146 146 146 173
AF 1~/3~ TPE [mm] - - - 146 146 146 173
P [mm] - - - 250 250 300 300
B1 ★ [mm] 93/- 100/- 100/- 134/288 134/288 142/298 142/298
B2 ★ [mm] 93/- 100/- 100/- 122/282 122/282 124/290 124/290
B3 [mm] - - - 320 320 320 320
C1 ★ [mm] 120/- 120/- 120/- 144/400 144/400 144/400 144/400
C5 ★ [mm] 170 170 170 180/65 180/65 180/65 180/65
C6 [mm] - - - 175 175 175 175
L1 [mm] 340 340 340 360 360 360 360
H1 [mm] 82 82 82 105 105 105 105
H2 [mm] 156 154 154 192 192 239 239
1~/3~ TP [mm] -/539 -/517 -/557 -/632 -/669 -/735 -/723
H3
1~/3~ TPE [mm] - - - -/631 -/631 -/709 -/733
H4 [mm] - - - - - - -
M [mm] M12 M12 M12 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

147
24
DN 65
2-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 65-XX/2

+
>P@


7373(

+]
 

 

 



 

 




      4>PñK@
3
>N:@


 
 




 
 



      4>PñK@
136+
>P@



      4>PñK@
(WD
>@ 

 

  







      4>PñK@
TM02 5041 2115

    4>OV@

     Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

148
24
DN 65
2-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 65 -480/2 -540/2 -630/2 -740/2 -910/2 -920/2 -1050/2


TPD ● ● ● ● ● ● ●
TPE ● ● ● ● - - -
TPED - - - - - - -
Series 300 300 300 300 300 300 300
1~ TP - - - - - - -
3~ TP 160 160 160 180 200 200 200
IEC size
1~ TPE - - - - - - -
3~ TPE 160 160 160 180 - - -
1~/3~ TP [kW] -/11 -/15 -/18.5 -/22 -/30 -/37 -/37
P2
1~/3~ TPE [kW] -/11 -/15 -/18.5 -/22 - - -
PN PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 65 65 65 65 65 65 65
1~/3~ TP [mm] -/314 -/314 -/314 -/314 -/396 -/407 -/396
AC
1~/3~ TPE [mm] -/255 -/314 -/314 -/314 - - -
1~/3~ TP [mm] -/204 -/204 -/204 -/204 -/315 -/315 -/315
AD
1~/3~ TPE [mm] -/237 -/308 -/308 -/308 - - -
AE 1~/3~ TPE [mm] 173 210 210 210 - - -
AF 1~/3~ TPE [mm] 173 210 210 210 - - -
P [mm] 350 350 350 350 400 400 400
B1 ★ [mm] 178/349 178/349 178/349 178/349 178/349 178/349 178/349
B2 ★ [mm] 164/383 164/383 164/383 164/383 164/383 164/383 164/383
B3 [mm] 440 440 440 440 440 440 440
C1 ★ [mm] 144/520 144/520 144/520 144/520 144/520 144/520 144/520
C5 ★ [mm] 238/111 238/111 238/111 238/111 238/111 238/111 238/111
C6 [mm] 175 175 175 175 175 175 175
L1 [mm] 475 475 475 475 475 475 475
H1 [mm] 125 125 125 125 125 125 125
H2 [mm] 263 263 263 263 263 263 263
1~/3~ TP [mm] -/859 -/859 -/903 -/903 -/951 -/999 -/976
H3
1~/3~ TPE [mm] -/794 -/859 -/903 -/929 - - -
H4 [mm] 35 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

149
24
DN 80
2-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 80-XX/2

+ +
>P@ >P@


7373( 
7373(

 +] +]
 





 


 


 




 

 
         4>PñK@         4>PñK@
3 3
>N:@ >N:@

  
 



 
 
 
 
 
 
 
 
 
         4>PñK@         4>PñK@
136+ 136+
>P@ >P@
  
 



 
 


 
 

 
         4>PñK@         4>PñK@
(WD (WD
>@ >@
 

 


  
 
  

  

 
 
 
         4>PñK@         4>PñK@
TM02 5042 2115

TM02 8769 2115

      4>OV@      4>OV@

      Y>PV@      Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

150
24
DN 80
2-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 5348 2614 - TM03 5349 2614
Technical data

TP 80 -160/2 -200/2 -240/2 -290/2 -330/2 -400/2 -480/2 -530/2 -640/2 -750/2
TPD - ● ● ● ● ● ● ● ● ●
TPE - ● ● ● ● ● ● ● - -
TPED - - - - - - - - - -
Series 200 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - - -
3~ TP 100 112 132 132 160 160 160 180 200 200
IEC size
1~ TPE - - - - - - - - - -
3~ TPE - 112 132 132 160 160 160 180 - -
1~/3~ TP [kW] -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 -/30 -/37
P2
1~/3~ TPE [kW] - -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22 - -
PN PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 80 80 80 80 80 80 80 80 80 80
1~/3~ TP [mm] -/175 -/220 -/220 -/260 -/314 -/314 -/314 -/314 -/396 -/396
AC
1~/3~ TPE [mm] - -/191 -/191 -/255 -/255 -/314 -/314 -/314 - -
1~/3~ TP [mm] -/110 -/134 -/134 -/159 -/204 -/204 -/204 -/204 -/315 -/315
AD
1~/3~ TPE [mm] - -/201 -/201 -/237 -/237 -/308 -/308 -/308 - -
AE 1~/3~ TPE [mm] - 146 146 173 173 210 210 210 - -
AF 1~/3~ TPE [mm] - 146 146 173 173 210 210 210 - -
P [mm] - 250 300 300 350 350 350 350 400 400
B1 ★ [mm] 125/- 125/260 125/260 125/260 176/366 176/366 187/416 187/416 187/416 187/416
B2 ★ [mm] 100/- 119/290 119/290 119/290 144/354 144/354 162/405 162/405 162/405 162/405
B3 [mm] - 340 340 340 400 400 470 470 470 470
C1 ★ [mm] 160/- 144/420 144/420 144/420 144/480 144/480 144/550 144/550 144/550 144/550
C5 ★ [mm] 180 180/78 180/78 180/78 220/93 220/93 250/133 250/133 250/133 250/133
C6 [mm] - 175 175 175 175 175 175 175 175 175
L1 [mm] 360 360 360 360 440 440 500 500 500 500
H1 [mm] 97 105 105 105 115 115 115 115 115 115
H2 [mm] 174 204 243 243 273 273 273 273 273 273
1~/3~ TP [mm] -/606 -/681 -/739 -/727 -/859 -/859 -/903 -/903 -/951 -/976
H3
1~/3~ TPE [mm] - -/643 -/713 -/737 -/794 -/859 -/903 -/929 - -
H4 [mm] - - - - 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

151
24
DN 100
2-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 100-XX/2

+ +
>P@ >P@


7373( 

7373(

+]  +]
 


 
 

 
 

 






 
        4>PñK@       4>PñK@
3 3
>N:@ >N:@
  


 


  


 
  
 
 
        4>PñK@       4>PñK@
136+ 136+
>P@ >P@

 

 

 

 


 

 
        4>PñK@       4>PñK@
(WD (WD
>@ >@
  
 
  

   

  

  
 
 
        4>PñK@       4>PñK@
TM02 8770 2115

TM02 8771 2115

     4>OV@        4>OV@

     Y>PV@         Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

152
24
DN 100
2-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 5348 2614 - TM03 5349 2614
Technical data
TP 100 -230/2 -300/2 -370/2 -350/2 -380/2 -530/2 -630/2 -700/2
TPD ● ● ● ● ● ● ● ●
TPE ● ● ● ● ● - - -
TPED - - - - - - - -
Series 300 300 300 300 300 300 300 300
1~ TP - - - - - - - -
3~ TP 132 160 160 160 180 200 200 225
IEC size
1~ TPE - - - - - - - -
3~ TPE 132 160 160 160 180 - - -
1~/3~ TP [kW] -/7.5 -/11 -/15 -/18.5 -/22 -/30 -/37 -/45
P2
1~/3~ TPE [kW] -/7.5 -/11 -/15 -/18.5 -/22 - - -
PN PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 100 100 100 100 100 100 100 100
1~/3~ TP [mm] -/260 -/314 -/314 -/314 -/314 -/396 -/396 -/449
AC
1~/3~ TPE [mm] -/255 -/255 -/314 -/314 -/314 - - -
1~/3~ TP [mm] -/159 -/204 -/204 -/204 -/204 -/315 -/315 -/338
AD
1~/3~ TPE [mm] -/237 -/237 -/308 -/308 -/308 - - -
AE 1~/3~ TPE [mm] 173 173 210 210 210 - - -
AF 1~/3~ TPE [mm] 173 173 210 210 210 - - -
P [mm] 300 350 350 350 350 400 400 450
B1 ★ [mm] 156/347 156/347 156/347 190/414 190/414 201/443 201/443 201/443
B2 ★ [mm] 124/332 124/332 124/332 151/395 151/395 173/429 173/429 173/429
B3 [mm] 400 400 400 470 470 500 500 500
C1 ★ [mm] 144/480 144/480 144/480 230/550 230/550 230/550 230/550 230/550
C5 ★ [mm] 250/104 250/104 250/104 275/110 275/110 275/110 275/110 275/110
C6 [mm] 175 175 175 230 230 230 230 230
L1 [mm] 500 500 500 550 550 550 550 550
H1 [mm] 140 140 140 140 140 140 140 140
H2 [mm] 245 275 275 270 270 307 307 337
1~/3~ TP [mm] -/764 -/886 -/886 -/925 -/925 -/1018 -/1035 -/1184
H3
1~/3~ TPE [mm] -/774 -/821 -/886 -/925 -/951 - - -
H4 [mm] - 35 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

153
24
DN 100
2-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 100-XX/2

H
[m]
180 TP, TPE 100
170 -1510/2 60 Hz
160
150
-1360/2
140
130 -1200/2
120 -1040/2
110
-940/2
100
90 -760/2

80
70
60
50
0 50 100 150 200 250 300 350 400 Q [m³/h]
P2
[kW]
-1510/2
200

160 -1360/2

-1200/2
120
-1040/2
-940/2
80 -760/2

40

0
0 50 100 150 200 250 300 350 400 Q [m³/h]
NPSH
[m]
28
-1040/2
24
-940/2
20
16 -760/2
12
-1200/2, -1360/2, -1510/2
8
4
0
0 50 100 150 200 250 300 350 400 Q [m³/h]
Eta
[%]
80
75 -1510/2
70 -760/2
-940/2 -1360/2
65 -1200/2
60 -1040/2

55
50
45
0 50 100 150 200 250 300 350 400 Q [m³/h]
TM06 6595 4717

0 20 40 60 80 100 120 Q [l/s]

0 2 4 6 8 10 12 14 v [m/s]

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

154
24
DN 100
2-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 5348 2614
Technical data
TP 100 -760/2 -940/2 -1040/2 -1200/2 -1360/2 -1510/2
TPD - - - - - -
TPE - - - - - -
TPED - - - - - -
Series 300 300 300 300 300 300
1~ TP - - - - - -
3~ TP 280S 280M 315S 315M 315L 315L
IEC size
1~ TPE - - - - - -
3~ TPE - - - - - -
1~/3~ TP [kW] -/75 -/90 -/110 -/132 -/160 -/200
P2
1~/3~ TPE [kW] - - - - - -
PN PN 25 PN 25 PN 25 PN 25 PN 25 PN 25
Tmin;Tmax [°C] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150]
D1 [mm] 100 100 100 100 100 100
1~/3~ TP [mm] -/555 -/555 -/610 -/610 -/610 -/610
AC
1~/3~ TPE [mm] - - - - - -
1~/3~ TP [mm] -/432 -/432 -/495 -/495 -/495 -/495
AD
1~/3~ TPE [mm] - - - - - -
AE 1~/3~ TPE [mm] - - - - - -
AF 1~/3~ TPE [mm] - - - - - -
P [mm] 550 550 660 660 660 658
B1 ★ [mm] 281/- 281/- 281/- 281/- 281/- 281/-
B2 ★ [mm] 246/- 246/- 246/- 246/- 246/- 246/-
B3 [mm] - - - - - -
C1 ★ [mm] 230 230 230 230 230 230
C5 ★ [mm] 335 335 335 335 335 335
C6 [mm] - - - - - -
L1 [mm] 670 670 670 670 670 670
H1 [mm] 175 175 175 175 175 175
H2 [mm] 338 338 366 366 366 366
1~/3~ TP [mm] -/1333 -/1443 -/1473 -/1633 -/1633 -/1360
H3
1~/3~ TPE [mm] - - - - - -
H4 [mm] 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

155
24
DN 32
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE, 4-pole, PN 6, 10, 16, 25


TP, TPD, TPE 32-XXX/4

+ +
>P@ >P@
 7373(  7373(

 +] +]






 

  







 
      4>PñK@        4>PñK@
3 3
>N:@ >N:@
 

 


  

  



 

 
      4>PñK@        4>PñK@
136+ 136+
>P@  >P@






 





 
      4>PñK@        4>PñK@
(WD (WD
>@ >@

 

  
  

 
 
 



 
      4>PñK@        4>PñK@
TM02 5046 2115

TM02 5047 2115

    4>OV@     4>OV@

    Y>PV@     Y>PV@
Note: All QH-curves apply to single-head pumps. For further information, see page 125.

156
24
DN 32
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 32 -40/4 -80/4 -120/4 -140/4 -190/4


TPD - - ● ● ●
TPE - - - - -
TPED - - - - -
Series 200 200 300 300 300
1~ TP - - - - -
3~ TP 71 71 80 80 90
IEC size
1~ TPE - - - - -
3~ TPE - - - - -
1~/3~ TP [kW] -/0.12 -/0.25 -/0.55 -/0.75 -/1.1
P2
1~/3~ TPE [kW] - - - - -
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120]
D1 [mm] 32 32 32 32 32
1~/3~ TP [mm] -/128 -/125 -/141 -/178 -/178
AC
1~/3~ TPE [mm] - - - - -
1~/3~ TP [mm] -/387 -/395 -/109 -/110 -/110
AD
1~/3~ TPE [mm] - - - - -
AE 1~/3~ TPE [mm] - - - - -
AF 1~/3~ TPE [mm] - - - - -
P [mm] - - 200 200 200
B1 ★ [mm] 75/- 102/- 144/321 144/321 144/321
B2 ★ [mm] 75/- 102/- 144/321 144/321 144/321
B3 [mm] - - 355 355 355
C1 ★ [mm] 80/- 80/- 144/435 144/435 144/435
C5 ★ [mm] 110 140 220/46 220/46 220/46
C6 [mm] - - 175 175 175
L1 [mm] 220 280 440 440 440
H1 [mm] 68 79 100 100 100
H2 [mm] 142 137 156 156 156
1~/3~ TP [mm] -/401 -/407 -/487 -/537 -/490
H3
1~/3~ TPE [mm] - - - - -
H4 [mm] - - - - -
M [mm] M12 M12 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

157
24
DN 40
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 40-XXX/4

+ +
>P@ >P@

7373(  7373(
 
+] +]
 






 

 
 

 
 

 
         4>PñK@        4>PñK@
3 3
>N:@ >N:@

 

 


 



 

 

 
         4>PñK@        4>PñK@
136+ 136+
>P@ >P@
 


 

 
 
 
 
 

 
         4>PñK@        4>PñK@
(WD (WD
>@ >@
 



 

  

 
 
 


 
 
         4>PñK@        4>PñK@
TM02 5048 2115

TM02 5049 2115

      4>OV@     4>OV@

    Y>PV@       Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

158
24
DN 40
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 40 -40/4 -80/4 -110/4 -150/4 -180/4 -230/4


TPD - - ● ● ● ●
TPE - - ● - - -
TPED - - - - - -
Series 200 200 300 300 300 300
1~ TP - - - - - -
3~ TP 71 80 80 90 90 100
IEC size
1~ TPE - - - - - -
3~ TPE - - 80 - - -
1~/3~ TP [kW] -/0.25 -/0.55 -/0.75 -/1.1 -/1.5 -/2.2
P2
1~/3~ TPE [kW] - - - - - -
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 40 40 40 40 40 40
1~/3~ TP [mm] -/142 -/142 -/178 -/178 -/178 -/198
AC
1~/3~ TPE [mm] - - - - - -
1~/3~ TP [mm] -/109 -/109 -/110 -/110 -/110 -/120
AD
1~/3~ TPE [mm] - - - - - -
AE 1~/3~ TPE [mm] - - - - - -
AF 1~/3~ TPE [mm] - - - - - -
P [mm] - - 200 200 200 250
B1 ★ [mm] 85/- 100/- 150/325 150/325 150/325 150/325
B2 ★ [mm] 75/- 100/- 147/325 147/325 147/325 147/325
B3 [mm] - - 355 355 355 355
C1 ★ [mm] 120/- 120/- 144/435 144/435 144/435 144/435
C5 ★ [mm] 125 125 220/108 220/108 220/108 220/108
C6 [mm] - - 175 175 175 175
L1 [mm] 250 250 440 440 440 440
H1 [mm] 67 75 110 110 110 110
H2 [mm] 132 135 156 156 156 184
1~/3~ TP [mm] -/390 -/441 -/547 -/587 -/587 -/629
H3
1~/3~ TPE [mm] - - - - - -
H4 [mm] - - - - - -
M [mm] M12 M12 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

159
24
DN 50
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 50-XXX/4

+ +
>P@ >P@
  7373( 7373(


+]  +]

 
 
 

 
 

  

 
 


 
         4>PñK@          4>PñK@
3 3
>N:@ >N:@

 



  

  

 

 

 
         4>PñK@          4>PñK@
136+ 136+
>P@ >P@

 
 

 

 

 




 
         4>PñK@          4>PñK@
(WD (WD
>@  >@
 

 

   
 
 
  


 
 
 
         4>PñK@          4>PñK@
TM02 5050 3315

TM02 5051 2115

      4>OV@        4>OV@

     Y>PV@       Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

160
24
DN 50
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 50 -40/4 -80/4 -100/4 -115/4 -130/4 -180/4 -240/4 -270/4 -340/4


TPD - - ● ● ● ● ● ● ●
TPE - - - - - - ● ● ●
TPED - - - - - - - - -
Series 200 200 300 300 300 300 300 300 300
1~ TP - - - - - - - - -
3~ TP 71 80 80 90 90 100 100 112 132
IEC size
1~ TPE - - - - - - - - -
3~ TPE - - - - - - 100 112 132
1~/3~ TP [kW] -/0.25 -/0.55 -/0.75 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5
P2
1~/3~ TPE [kW] - - - - - - -/3 -/4 -/5.5
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 50 50 50 50 50 50 50 50 50
1~/3~ TP [mm] -/142 -/142 -/178 -/178 -/178 -/198 -/198 -/220 -/260
AC
1~/3~ TPE [mm] - - - - - - -/191 -/191 -/255
1~/3~ TP [mm] -/109 -/109 -/110 -/110 -/110 -/120 -/120 -/134 -/159
AD
1~/3~ TPE [mm] - - - - - - -/201 -/201 -/237
AE 1~/3~ TPE [mm] - - - - - - 146 146 173
AF 1~/3~ TPE [mm] - - - - - - 146 146 173
P [mm] - - 200 200 200 250 250 250 300
B1 ★ [mm] 90/- 110/- 162/373 162/373 162/373 162/373 180/386 180/386 180/386
B2 ★ [mm] 75/- 100/- 162/373 162/373 162/373 162/373 164/379 164/379 164/379
B3 [mm] - - 420 420 420 420 420 420 420
C1 ★ [mm] 120/- 120/- 144/500 144/500 144/500 144/500 144/500 144/500 144/500
C5 ★ [mm] 140 140 220/123 220/123 220/123 220/123 220/123 220/123 220/123
C6 [mm] - - 175 175 175 175 175 175 175
L1 [mm] 280 280 440 440 440 440 440 440 440
H1 [mm] 82 82 115 115 115 115 115 115 115
H2 [mm] 136 140 160 160 167 188 195 195 234
1~/3~ TP [mm] -/409 -/453 -/556 -/556 -/603 -/638 -/645 -/682 -/728
H3
1~/3~ TPE [mm] - - - - - - -/644 -/644 -/738
H4 [mm] - - - - - - - - -
M [mm] M12 M12 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

161
24
DN 65
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 65-XXX/4

+ +
>P@ >P@

  7373( 7373(


 
+] +]

 



 






 


 

 
         4>PñK@        4>PñK@
3 3
>N:@ >N:@

 
 
 


  

 



 

 
         4>PñK@        4>PñK@
136+ 136+
>P@ 
>P@
 


 

 

 


 
         4>PñK@        4>PñK@
(WD (WD
>@ >@
  

 
 
   
  

 
 
  
 
         4>PñK@        4>PñK@
TM02 5052 2115

TM02 5053 2115

       4>OV@     4>OV@

       Y>PV@       Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

162
24
DN 65
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM02 8632 2614 - TM02 8631 2614
Technical data

TP 65 -40/4 -80/4 -130/4 -150/4 -190/4 -230/4 -310/4 -330/4


TPD - - ● ● ● ● ● ●
TPE - - - - ● ● ● ●
TPED - - - - - - - -
Series 200 200 300 300 300 300 300 300
1~ TP - - - - - - - -
3~ TP 71 90 90 100 100 112 132 132
IEC size
1~ TPE - - - - - - - -
3~ TPE - - - - 100 112 132 160
1~/3~ TP [kW] -/0.37 -/1.1 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5
P2
1~/3~ TPE [kW] - - - - -/3 -/4 -/5.5 -/7.5
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 65 65 65 65 65 65 65 65
1~/3~ TP [mm] -/142 -/175 -/178 -/198 -/198 -/220 -/260 -/260
AC
1~/3~ TPE [mm] - - - - -/191 -/191 -/255 -/255
1~/3~ TP [mm] -/125 -/125 -/110 -/120 -/120 -/134 -/159 -/159
AD
1~/3~ TPE [mm] - - - - -/201 -/201 -/237 -/237
AE 1~/3~ TPE [mm] - - - - 146 146 173 173
AF 1~/3~ TPE [mm] - - - - 146 146 173 173
P [mm] - - 200 250 250 250 300 300
B1 ★ [mm] 125/- 125/- 178/349 178/349 178/349 178/349 178/349 178/349
B2 ★ [mm] 100/- 100/- 164/383 164/383 164/383 164/383 164/383 164/383
B3 [mm] - - 440 440 440 440 440 440
C1 ★ [mm] 160/- 160/- 144/520 144/520 144/520 144/520 144/520 144/520
C5 ★ [mm] 170 170 238/111 238/111 238/111 238/111 238/111 238/111
C6 [mm] - - 175 175 175 175 175 175
L1 [mm] 340 340 475 475 475 475 475 475
H1 [mm] 97 97 125 125 125 125 125 125
H2 [mm] 136 158 166 194 194 194 233 233
1~/3~ TP [mm] -/424 -/536 -/612 -/654 -/654 -/691 -/737 -/787
H3
1~/3~ TPE [mm] - - - - -/653 -/653 -/747 -/747
H4 [mm] - - - - - - - 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

163
24
DN 80
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 80-XXX/4

+ +
>P@ >P@
 7373(  7373(
+]  +]

 

  
 

 
 


 

 


 

 

 
        4>PñK@         4>PñK@
3 3
>N:@ >N:@

 
 

  
  

  
 
 
 
 

 
        4>PñK@         4>PñK@
136+ 136+
>P@  >P@
  
 


 

 

 

 

 
 
        4>PñK@         4>PñK@
(WD (WD
>@  >@
   
   
   

 
 
  
 
 
 
        4>PñK@         4>PñK@
TM02 5054 2115

TM02 8772 2115

     4>OV@      4>OV@

     Y>PV@      Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

164
24
DN 80
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 5348 2614 - TM03 5349 2614
Technical data

TP 80 -40/4 -80/4 -110/4 -150/4 -170/4 -230/4 -280/4 -340/4 -410/4 -460/4 -510/4
TPD - - ● ● ● ● ● ● ● ● ●
TPE - - - ● ● ● ● ● ● ● -
TPED - - - - - - - - - - -
Series 200 200 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - - - -
3~ TP 80 90 100 100 112 132 132 160 160 180 180
IEC size
1~ TPE - - - - - - - - - - -
3~ TPE - - - 112 112 132 160 160 160 180 -
1~/3~ TP [kW] -/0.75 -/1.5 -/2.2 -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/22
P2
1~/3~ TPE [kW] - - - -/3 -/4 -/5.5 -/7.5 -/11 -/15 -/18.5 -/-
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 80 80 80 80 80 80 80 80 80 80 80
1~/3~ TP [mm] -/178 -/175 -/198 -/198 -/220 -/267 -/260 -/314 -/314 -/368 -/368
AC
1~/3~ TPE [mm] - - - -/191 -/191 -/255 -/255 -/314 -/314 -/314 -/-
1~/3~ TP [mm] -/110 -/135 -/120 -/120 -/134 -/167 -/159 -/204 -/204 -/286 -/268
AD
1~/3~ TPE [mm] - - - -/201 -/201 -/237 -/237 -/308 -/308 -/308 -/-
AE 1~/3~ TPE [mm] - - - 146 146 173 173 210 210 210 -/-
AF 1~/3~ TPE [mm] - - - 146 146 173 173 210 210 210 -/-
P [mm] 115 - 250 250 250 300 300 350 350 350 350
B1 ★ [mm] 130/- 135/- 176/366 187/416 187/416 243/491 243/491 243/491 243/491 243/491 243/491
B2 ★ [mm] 100/- 100/- 144/354 162/405 162/405 226/480 226/480 226/480 226/480 226/480 226/480
B3 [mm] - - 400 470 470 470 470 470 470 470 470
C1 ★ [mm] 160/- 160/- 144/480 144/550 144/550 230/550 230/550 230/550 230/550 230/550 230/550
C5 ★ [mm] 180 180 220/93 250/133 250/133 310/105 310/105 310/105 310/105 310/105 310/105
C6 [mm] - - 175 175 175 350 350 350 350 350 350
L1 [mm] 360 360 440 500 500 620 620 620 620 620 620
H1 [mm] 107 107 115 115 115 140 140 140 140 140 140
H2 [mm] 175 164 204 204 204 273 273 303 303 303 303
1~/3~ TP [mm] -/563 -/592 -/654 -/654 -/691 -/786 -/842 -/914 -/958 -/958 -/1049
H3
1~/3~ TPE [mm] - - - -/654 -/654 -/802 -/802 -/914 -/958 -/984 -/-
H4 [mm] - - - - - - 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

165
24
DN 100
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 100-XXX/4

+
>P@
 7373(
  +]

 













       4>PñK@
3
>N:@





 


 

 


       4>PñK@
136+
>P@
 




 

 





       4>PñK@
(WD
>@


 


 



 


       4>PñK@
TM02 5055 2915

        4>OV@

         Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

166
24
DN 100
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 5348 2614 - TM03 5349 2614
Technical data

TP 100 -40/4 -80/4 -100/4 -130/4 -150/4 -170/4


TPD - - ● ● ● ●
TPE - - ● ● ● ●
TPED - - - - - -
Series 200 200 300 300 300 300
1~ TP - - - - - -
3~ TP 90 100 100 112 132 132
IEC size
1~ TPE - - - - - -
3~ TPE - - 112 112 113 132
1~/3~ TP [kW] -/1.1 -/2.2 -/3 -/4 -/5.5 -/5.5
P2
1~/3~ TPE [kW] - - -/3 -/4 -/5.5 -/5.5
PN PN 6/10 PN 6/10 PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 100 100 100 100 100 100
1~/3~ TP [mm] -/175 -/175 -/198 -/220 -/260 -/260
AC
1~/3~ TPE [mm] - - -/191 -/191 -/255 -/255
1~/3~ TP [mm] -/174 -/174 -/120 -/134 -/159 -/159
AD
1~/3~ TPE [mm] - - -/201 -/201 -/237 -/237
AE 1~/3~ TPE [mm] - - 146 146 173 173
AF 1~/3~ TPE [mm] - - 146 146 173 173
P [mm] - - 250 250 300 300
B1 ★ [mm] 174/- 174/- 190/414 201/443 190/414 201/443
B2 ★ [mm] 120/- 120/- 151/395 173/429 151/395 173/429
B3 [mm] - - 470 500 470 500
C1 ★ [mm] 200/- 200/- 230/550 230/550 230/550 230/550
C5 ★ [mm] 225 225 275/110 275/110 275/110 275/110
C6 [mm] - - 230 230 230 230
L1 [mm] 450 450 550 550 550 550
H1 [mm] 122 122 140 140 140 140
H2 [mm] 183 193 201 261 240 277
1~/3~ TP [mm] -/585 -/650 -/676 -/773 -/759 -/796
H3
1~/3~ TPE [mm] - - -/675 -/731 -/769 -/806
H4 [mm] - - - - - -
M [mm] M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

167
24
DN 100
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 100-XXX/4

+
>P@
 7373(
 +]





 


 


 

 



      4>PñK@
3
>N:@






 

 

 



      4>PñK@
136+
>P@ 
 
 






 


      4>PñK@
(WD
>@
 
  
 

 

  





      4>PñK@
TM02 8773 2115

       4>OV@

        Y>PV@

Note: All QH curves apply to single-head pumps. For further information, see page 125.

168
24
DN 100
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 5348 2614 - TM03 5349 2614
Technical data

TP 100 -200/4 -240/4 -260/4 -290/4 -340/4 -350/4 -390/4 -470/4 -560/4
TPD ● ● ● ● ● ● ● ● -
TPE ● ● ● ● ● - ● - -
TPED - - - - - - - - -
Series 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - -
3~ TP 132 160 160 160 180 160 180 200 225S
IEC size
1~ TPE - - - - - - - -
3~ TPE 160 160 161 160 180 180 - -
1~/3~ TP [kW] -/7.5 -/11 -/11 -/15 -/18.5 -/22 -/22 -/30 -/37
P2
1~/3~ TPE [kW] -/7.5 -/11 -/11 -/15 -/18.5 - -/22 - -
PN PN16/25 PN16/25 PN 16 PN16/25 PN16/25 PN 16 PN16/25 PN16/25 PN 25
Tmin;Tmax [°C] [-40;150] [-40;150] [-25;120] [-40;150] [-40;150] [-25;120] [-40;150] [-40;150] [-40;150]
D1 [mm] 100 100 100 100 100 100 100 100 100
1~/3~ TP [mm] -/260 -/314 -/314 -/314 -/368 -/363 -/368 -/408 -/442
AC
1~/3~ TPE [mm] -/255 -/314 -/314 -/314 -/314 - -/350 - -
1~/3~ TP [mm] -/159 -/204 -/204 -/204 -/286 -/262 -/286 -/315 -/325
AD
1~/3~ TPE [mm] -/237 -/308 -/308 -/308 -/308 - -/439 - -
AE 1~/3~ TPE [mm] 173 210 210 210 210 - 164 - -
AF 1~/3~ TPE [mm] 173 210 210 210 210 - 164 - -
P [mm] 300 350 350 350 350 350 350 400 450
B1 ★ [mm] 290/579 290/579 201/443 290/579 290/579 290/579 290/579 290/579 281/-
B2 ★ [mm] 249/561 249/561 173/429 249/561 249/561 249/561 249/561 249/561 246/-
B3 [mm] 600 600 500 600 600 600 600 600 -
C1 ★ [mm] 230/680 230/680 230/550 230/680 230/680 230/680 230/680 230/680 230
C5 ★ [mm] 335/110 335/110 275/110 335/110 335/110 335/110 335/110 335/110 335
C6 [mm] 350 350 230 350 350 350 350 350 -
L1 [mm] 670 670 550 670 670 670 670 670 670
H1 [mm] 175 175 140 175 175 175 175 175 175
H2 [mm] 254 308 307 308 308 308 308 308 313
1~/3~ TP [mm] -/858 -/954 -/826 -/998 -/998 -/1093 -/1079 -/1128 -/1150
H3
1~/3~ TPE [mm] -/842 -/954 -/826 -/998 -/998 - -/1008 - -
H4 [mm] - 35 35 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

169
24
DN 125
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 125-XXX/4

+
>P@


7373(
 +]





 






         4>PñK@
3
>N:@
 


 

 


         4>PñK@
136+
>P@





 


         4>PñK@
(WD
>@



  
 





         4>PñK@
TM06 3851 2115

      4>OV@

    Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

170
24
DN 125
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM05 9447 2614

Technical data

TP 125 -80/4 -110/4 -135/4


TPD - - -
TPE ● ● ●
TPED - - -
Series 300 300 300
1~ TP - - -
3~ TP 100 112 132
IEC size
1~ TPE - - -
3~ TPE 100 112 132
1~/3~ TP [kW] -/3 -/4 -/5.5
P2
1~/3~ TPE [kW] -/3 -/4 -/5.5
PN PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120]
D1 [mm] 125 125 125
1~/3~ TP [mm] -/198 -/220 -/267
AC
1~/3~ TPE [mm] -/191 -/191 -/255
1~/3~ TP [mm] -/120 -/134 -/167
AD
1~/3~ TPE [mm] -/201 -/201 -/237
AE 1~/3~ TPE [mm] -/146 -/146 -/173
AF 1~/3~ TPE [mm] -/146 -/146 -/173
P [mm] 250 250 300
B1 ★ [mm] 243/- 243/- 243/-
B2 ★ [mm] 193/- 193/- 193/-
L1 [mm] 620 620 620
H1 [mm] 210 210 210
H2 [mm] -/225 -/225 -/245
1~/3~ TP [mm] -/770 -/807 -/834
H3
1~/3~ TPE [mm] -/769 -/769 -/844
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

171
24
DN 125
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 125-XXX/4

+ +
>P@ >P@
 7373(  7373(

+]   +]

  
 
 
  

 


  

  

  

 
 
      4>PñK@         4>PñK@
3 3
>N:@ >N:@
 

  


 


  

 
 
 
   
 
 
      4>PñK@         4>PñK@
136+ 136+
>P@ >P@
 




 
  

 
  


  

 
      4>PñK@         4>PñK@
(WD (WD
>@ >@
  
 
 
 
 
 
 
  
  


 
 
 
      4>PñK@         4>PñK@
TM02 8774 2115

TM02 8775 2115

       4>OV@          4>OV@

      Y>PV@        Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

172
24
DN 125
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 5348 2614 - TM03 5349 2614
Technical data

TP 125 -130/4 -160/4 -200/4 -230/4 -220/4 -280/4 -340/4 -365/4 -420/4 -480/4 -550/4 -580/4
TPD ● ● ● ● - ● ● ● ● ● - -
TPE ● ● ● ● ● ● - - ● ● - -
TPED - - - - - - - - - - - -
Series 300 300 300 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - - - - -
3~ TP 132 132 160 160 160 180 180 200 200 225 225M 225M
IEC size
1~ TPE - - - - - - - - - - - -
3~ TPE 132 132 160 160 160 180 - - - - - -
1~/3~ TP [kW] -/5.5 -/7.5 -/11 -/15 -/15 -/18.5 -/22 -/30 -/30 -/37 -/45 -/55
P2
1~/3~ TPE [kW] -/5.5 -/7.5 -/11 -/15 -/15 -/18.5 - - - - - -
PN PN 16 PN 16 PN 16 PN 16 PN 25 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140] [-40;150] [-40;150]
D1 [mm] 125 125 125 125 125 125 125 125 125 125 125 125
1~/3~ TP [mm] -/267 -/267 -/314 -/314 -/314 -/368 -/368 -/408 -/408 -/449 -/442 -/495
AC
1~/3~ TPE [mm] -/255 -/255 -/314 -/314 -/314 -/314 - - - - - -
1~/3~ TP [mm] -/167 -/167 -/204 -/204 -/204 -/286 -/286 -/315 -/315 -/338 -/325 -/392
AD
1~/3~ TPE [mm] -/237 -/237 -/308 -/308 -/308 -/308 - - - - - -
AE 1~/3~ TPE [mm] -/173 -/173 -/210 -/210 -/210 -/210 - - - - - -
AF 1~/3~ TPE [mm] -/173 -/173 -/210 -/210 -/210 -/210 - - - - - -
P [mm] 300 300 350 350 350 350 350 350 400 450 450 550
B1 ★ [mm] 250/537 250/537 250/537 250/537 244/537 244/537 244/537 244/537 273/568 273/568 271/- 271/-
B2 ★ [mm] 220/518 220/518 220/518 220/518 220/516 220/516 220/516 220/516 236/545 236/545 243/- 243/-
B3 [mm] 600 600 600 600 600 600 600 600 600 600 - -
C1 ★ [mm] 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230/680 230 230
C5 ★ [mm] 310/84 310/84 310/84 310/84 400/175 400/175 400/175 400/175 400/175 400/175 400 400
C6 [mm] 300 300 300 300 -/350 -/350 -/350 -/350 350 350 - -
L1 [mm] 620 620 620 620 800 800 800 800 800 800 800 800
H1 [mm] 215 215 215 215 215 215 215 215 215 215 215 215
H2 [mm] 283 283 283 312.5 315 315 315 315 312 342 348 353
1~/3~ TP [mm] -/870 -/908 -/870 -/1042.5 -/1105 -/1088 -/1118 -/1166 -/1163 -/1205 -/1271 -/1384
H3
1~/3~ TPE [mm] -/887 -/887 -/873 -/1042.5 -/1045 -/1071 - - - - - -
H4 [mm] - 35 35 35 35 35 35 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

173
24
DN 150
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 150-XXX/4

+
>P@
 7373(
 +]


 


 

 







        4>PñK@
3
>N:@



 










        4>PñK@
136+
>P@
 
 
 








        4>PñK@
(WD
>@





 







        4>PñK@
TM06 3852 2115

      4>OV@

       Y>PV@

Note: All QH curves apply to single-head pumps. For further information, see page 125.

174
24
DN 150
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM05 0661 2614
Technical data

TP 150 -130/4 -160/4 -200/4 -220/4


TPD - - - -
TPE ● ● ● -
TPED - - - -
Series 300 300 300 300
1~ TP - - - -
3~ TP 160 160 180 180
IEC size
1~ TPE - - - -
3~ TPE 160 160 180 -
1~/3~ TP [kW] -/11 -/15 -/18.5 -/22
P2
1~/3~ TPE [kW] -/11 -/15 -/18.5 -
PN PN 16 PN 16 PN 16 PN 16
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120]
D1 [mm] 150 150 150 150
1~/3~ TP [mm] -/320 -/320 -/368 -/368
AC
1~/3~ TPE [mm] -/314 -/314 -/314 -
1~/3~ TP [mm] -/197 -/197 -/286 -/286
AD
1~/3~ TPE [mm] -/308 -/308 -/308 -
AE 1~/3~ TPE [mm] -/210 -/210 -/210 -
AF 1~/3~ TPE [mm] -/210 -/210 -/210 -
P [mm] 350 350 350 350
B1 ★ [mm] 295/- 295/- 295/- 295/-
B2 ★ [mm] 240/- 240/- 240/- 240/-
L1 [mm] 800 800 800 800
H1 [mm] 250 250 250 250
H2 [mm] 314 314 314 314
1~/3~ TP [mm] -/1109 -/1139 -/1122 -/1152
H3
1~/3~ TPE [mm] -/1079 -/1079 -/1105 -
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

175
24
DN 150
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 150-XXX/4

+
>P@
 7373(
 +]



 




 
 





          4>PñK@
3
>N:@ 








 




          4>PñK@
136+
>P@








          4>PñK@
(WD
>@





 
 






          4>PñK@
TM02 8776 2115

      4>OV@

      Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

176
24
DN 150
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 5348 2614 - TM03 5349 2614
Technical data

TP 150 -180/4 -210/4 -240/4 -300/4 -340/4


TPD ● ● ● ● ●
TPE ● ● ● - -
TPED - - - - -
Series 300 300 300 300 300
1~ TP - - - - -
3~ TP 160 180 180 200 225
IEC size
1~ TPE - - - - -
3~ TPE 160 180 180 - -
1~/3~ TP [kW] -/15 -/18.5 -/22 -/30 -/37
P2
1~/3~ TPE [kW] -/15 -/18.5 -/22 - -
PN PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25
Tmin;Tmax [°C] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140]
D1 [mm] 150 150 150 150 150
1~/3~ TP [mm] -/314 -/368 -/368 -/408 -/442
AC
1~/3~ TPE [mm] -/314 -/314 -/350 - -
1~/3~ TP [mm] -/204 -/286 -/286 -/315 -/325
AD
1~/3~ TPE [mm] -/308 -/308 -/439 - -
AE 1~/3~ TPE [mm] 210 210 164 - -
AF 1~/3~ TPE [mm] 210 210 164 - -
P [mm] 350 350 350 400 450
B1 ★ [mm] 296/583 296/583 296/583 296/583 296/583
B2 ★ [mm] 237/553 237/553 237/553 237/553 237/553
B3 [mm] 600 600 600 600 600
C1 ★ [mm] 230/680 230/680 230/680 230/680 230/680
C5 ★ [mm] 400/153 400/153 400/153 400/153 400/153
C6 [mm] 350 350 350 350 350
L1 [mm] 800 800 800 800 800
H1 [mm] 215 215 215 215 215
H2 [mm] 321 321 321 321 351.5
1~/3~ TP [mm] -/1052 -/1052 -/1133 -/1182 -/1215.5
H3
1~/3~ TPE [mm] -/1052 -/1078 -/1062 - -
H4 [mm] 35 35 35 35 35
M [mm] M16 M16 M16 M16 M16
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

177
24
DN 150
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPE 150-XXX/4

+
>P@
7373(

+]














        4>PñK@
3
>N:@





 






        4>PñK@
136+
>P@
 



 






        4>PñK@
(WD
>@


 







        4>PñK@
TM03 4652 2115

      4>OV@

      Y>PV@

Note: All QH-curves apply to single-head pumps. For further information, see page 125.

178
24
DN 150
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 8623 2614

Technical data

TP 150 -360/4 -400/4


TPD - -
TPE - -
TPED - -
Series 300 300
1~ TP - -
3~ TP 200 225
IEC size
1~ TPE - -
3~ TPE - -
1~/3~ TP [kW] -/30 -/37
P2
1~/3~ TPE [kW] - -
PN PN 16/25 PN 16/25
Tmin;Tmax [°C] [-40;140] [-40;140]
D1 [mm] 150 150
1~/3~ TP [mm] -/408 -/449
AC
1~/3~ TPE [mm] - -
1~/3~ TP [mm] -/315 -/338
AD
1~/3~ TPE [mm] - -
AE 1~/3~ TPE [mm] - -
AF 1~/3~ TPE [mm] - -
P [mm] 400 450
B1 ★ [mm] 335/- 335/-
B2 ★ [mm] 288/- 288/-
L1 [mm] 800 800
H1 [mm] 235 235
H2 [mm] 319 349
1~/3~ TP [mm] -/1199 -/1232
H3
1~/3~ TPE [mm] - -
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

179
24
DN 150
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP, TPD, TPE 150-XXX/4

+
>P@
 7373(
  +]







 

 




          4>PñK@
3
>N:@
 
 


 
 
 



          4>PñK@
136+
>P@



 
 



 



          4>PñK@
(WD
>@

 


   
  





          4>PñK@
TM05 0539 2115

        4>OV@

        Y>PV@

180
24
DN 150
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM05 0662 2614

Technical data

TP 150 -440/4 -480/4 -610/4 -700/4 -810/4 -960/4


TPD - - - - - -
TPE - - - - - -
TPED - - - - - -
Series 300 300 300 300 300 300
1~ TP - - - - - -
3~ TP 225 250 280 280 315 315
IEC size
1~ TPE - - - - - -
3~ TPE - - - - - -
1~/3~ TP [kW] -/45 -/55 -/75 -/90 -/110 -/132
P2
1~/3~ TPE [kW] - - - - - -
PN PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25
Tmin;Tmax [°C] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140]
D1 [mm] 150 150 150 150 150 150
1~/3~ TP [mm] -/449 -/497 -/551 -/551 -/610 -/610
AC
1~/3~ TPE [mm] - - - - - -
1~/3~ TP [mm] -/338 -/410 -/433 -/433 -/495 -/495
AD
1~/3~ TPE [mm] - - - - - -
AE 1~/3~ TPE [mm] - - - - - -
AF 1~/3~ TPE [mm] - - - - - -
P [mm] 450 550 550 550 660 660
B1 ★ [mm] 373/- 373/- 373/- 373/- 373/- 373/-
B2 ★ [mm] 333/- 333/- 333/- 333/- 333/- 333/-
L1 [mm] 1000 1000 1000 1000 1000 1000
H1 [mm] 250 250 250 250 250 250
H2 [mm] 352 352 352 352 377 377
1~/3~ TP [mm] -/1315 -/1349 -/1422 -/1532 -/1589 -/1749
H3
1~/3~ TPE [mm] - - - - - -
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

181
24
DN 200
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP 200-XXX/4

+ +
>P@ >P@
  7373(  
7373(
 
+] +]


 
  

 

 



 





 
      4>PñK@         4>PñK@
3 3
>N:@ >N:@
  
 


 
 

 

 


 
 
 
      4>PñK@         4>PñK@
136+ 136+
>P@  >P@ 
  

 
  


  

 

 

 
      4>PñK@         4>PñK@
(WD (WD
>@ >@
 

 

  
    

 
  
  
  
 
 
      4>PñK@         4>PñK@
TM05 0541 2115

TM05 0543 2115

         4>OV@            4>OV@

      Y>PV@        Y>PV@

182
24
DN 200
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TP 200-80/4 TP 200-250/4
TP 200-110/4 TP 200-280/4
TP 200-140/4 TP 200-320/4
TP 200-190/4 TP 200-360/4
TP 200-210/4 TP 200-390/4

TM05 0663 2614 - TM05 0664 2614


Technical data

TP 200 -80/4 -110/4 -140/4 -190/4 -210/4 -250/4 -280/4 -320/4 -360/4 -390/4
TPD - - - - - - - - - -
TPE ● ● ● ● - - - - - -
TPED - - - - - - - - - -
Series 300 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - - -
3~ TP 132 160 160 180 180 200 225 225 250 280
IEC size
1~ TPE - - - - - - - - - -
3~ TPE 132 160 160 180 - - - - - -
1~/3~ TP [kW] -/7.5 -/11 -/15 -/18.5 -/22 -/30 -/37 -/45 -/55 -/75
P2
1~/3~ TPE [kW] -/7.5 -/11 -/15 -/18.5 - - - - - -
PN PN16 PN16 PN16 PN16 PN16 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25
Tmin;Tmax [°C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140]
D1 [mm] 200 200 200 200 200 200 200 200 150 150
1~/3~ TP [mm] -/267 -/320 -/320 -/368 -/368 -/408 -/449 -/449 -/497 -/551
AC
1~/3~ TPE [mm] -/255 -/314 -/314 -/314 - - - - - -
1~/3~ TP [mm] -/167 -/197 -/197 -/286 -/286 -/315 -/338 -/338 -/410 -/433
AD
1~/3~ TPE [mm] -/237 -/308 -/308 -/308 - - - - - -
AE 1~/3~ TPE [mm] -/173 -/210 -/210 -/210 - - - - - -
AF 1~/3~ TPE [mm] -/173 -/210 -/210 -/210 - - - - - -
P [mm] 300 350 350 350 350 400 450 450 550 550
B1 ★ [mm] 296/- 363/- 363/- 363/- 363/- 348/- 348/- 348/- 348/- 348/-
B2 ★ [mm] 237/- 283/- 283/- 283/- 283/- 288/- 288/- 288/- 288/- 288/-
L1 [mm] 900 900 900 900 900 900 900 900 900 900
H1 [mm] 280 280 280 280 280 280 280 280 280 280
H2 [mm] -/336 -/336 -/336 -/336 -/336 -/331 -/361 -/361 -/361 -/361
1~/3~ TP [mm] -/1026 -/1094 -/1134 -/1130 -/1160 -/1256 -/1298 -/1358 -/1397 -/1470
H3
1~/3~ TPE [mm] -/975 -/1094 -/1134 -/1174 - - - - - -
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

183
24
DN 200
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP 200-XXX/4

+
>P@


7373(
 +]















        4>PñK@
3
>N:@



 
 




        4>PñK@
136+
>P@










        4>PñK@
(WD
>@





 






        4>PñK@
TM03 8592 2115

     4>OV@

        Y>PV@

184
24
DN 200
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 8621 2614

Technical data

TP 200 -400/4 -440/4 -500/4


TPD - - -
TPE - - -
TPED - - -
Series 300 300 300
1~ TP - - -
3~ TP 280 280 315
IEC size
1~ TPE - - -
3~ TPE - - -
1~/3~ TP [kW] -/75 -/90 -/110
P2
1~/3~ TPE [kW] - - -
PN PN 16/25 PN 16/25 PN 16/25
Tmin;Tmax [°C] [-40;140] [-40;140] [-40;140]
D1 [mm] 200 200 200
1~/3~ TP [mm] -/551 -/551 -/616
AC
1~/3~ TPE [mm] - - -
1~/3~ TP [mm] -/433 -/433 -/515
AD
1~/3~ TPE [mm] - - -
AE 1~/3~ TPE [mm] - - -
AF 1~/3~ TPE [mm] - - -
P [mm] 550 550 660
B1 ★ [mm] 393/- 393/- 393/-
B2 ★ [mm] 328/- 328/- 328/-
L1 [mm] 900 900 900
H1 [mm] 295 295 295
H2 [mm] 377 377 407
1~/3~ TP [mm] -/1492 -/1602 -/1614
H3
1~/3~ TPE [mm] - - -
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

185
24
DN 200
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP 200-XXX/4

+
>P@
7373(
  +]
 















        4>PñK@
3
>N:@
 







 




        4>PñK@
136+
>P@








        4>PñK@
(WD
>@



 

  
 




        4>PñK@
TM03 8593 2115

     4>OV@

        Y>PV@

186
24
DN 200
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM03 8622 2614
Technical data

TP 200 -430/4 -490/4 -540/4 -600/4 -680/4 -770/4


TPD - - - - - -
TPE - - - - - -
TPED - - - - - -
Series 300 300 300 300 300 300
1~ TP - - - - - -
3~ TP 250 280 280 315 315 315
IEC size
1~ TPE - - - - - -
3~ TPE - - - - - -
1~/3~ TP [kW] -/55 -/75 -/90 -/110 -/132 -/160
P2
1~/3~ TPE [kW] - - - - - -
PN PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25 PN 16/25
Tmin;Tmax [°C] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140] [-40;140]
D1 [mm] 200 200 200 200 200 200
1~/3~ TP [mm] -/497 -/551 -/551 -/616 -/616 -/616
AC
1~/3~ TPE [mm] - - - - - -
1~/3~ TP [mm] -/433 -/433 -/433 -/515 -/515 -/515
AD
1~/3~ TPE [mm] - - - - - -
AE 1~/3~ TPE [mm] - - - - - -
AF 1~/3~ TPE [mm] - - - - - -
P [mm] 550 550 550 660 660 660
B1 ★ [mm] 423/- 423/- 423/- 423/- 423/- 423/-
B2 ★ [mm] 368/- 368/- 368/- 368/- 368/- 368/-
L1 [mm] 1000 1000 1000 1000 1000 1000
H1 [mm] 295 295 295 295 295 295
H2 [mm] 382 382 382 412 412 412
1~/3~ TP [mm] -/1424 -/1497 -/1607 -/1619 -/1784 -/1784
H3
1~/3~ TPE [mm] - - - - - -
★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

187
24
DN 300
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP 300-XXX/4

H H
[m] [m]
TP, TPE 300 TP, TPE 300
70 80
-630/4 60 Hz -750/4 60 Hz
60 -550/4 70
-640/4
-440/4
50 60
-370/4
40 50
-360/4
-270/4
30 40
-230/4
20 30

10 20

0 10
0 200 400 600 800 1000 1200 Q [m³/h] 0 200 400 600 800 1000 1200 1400 Q [m³/h]
P2 P2
[kW] [kW]
160 -750/4
-630/4 240
140
-550/4 200 -640/4
120
-440/4
100 160
-370/4
80
-360/4 120
60
-270/4 80
40 -230/4
20 40
0 200 400 600 800 1000 1200 Q [m³/h] 0 200 400 600 800 1000 1200 1400 Q [m³/h]
NPSH NPSH
[m] [m]
-370/4
18 18
-640/4
16 -750/4
-270/4 16
14
-230/4 14
12
12
10
10
8 -630/4
-550/4 8
6
-440/4
-360/4
4 6
0 200 400 600 800 1000 1200 Q [m³/h] 0 200 400 600 800 1000 1200 1400 Q [m³/h]
Eta Eta
[%] [%]
90 90
-360/4
85 85
-750/4
80 80
-630/4
75 75
-640/4
70 70
-550/4
65 -440/4
-230/4 -370/4
65
60 -270/4 60
55 55
50 50
0 200 400 600 800 1000 1200 Q [m³/h] 0 200 400 600 800 1000 1200 1400 Q [m³/h]
TM06 6596 4717

TM06 6622 4717

0 100 200 300 Q [l/s] 0 100 200 300 400 Q [l/s]

0 1 2 3 4 5 v [m/s] 0 1 2 3 4 5 6 v [m/s]

188
24
DN 300
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM06 6532 1716

Technical data

TP 300 -230/4 -270/4 -360/4 -370/4 -440/4 -550/4 -630/4 -640/4 -750/4
TPD - - - - - - - - -
TPE - - - - - - - - -
TPED - - - - - - - - -
Series 300 300 300 300 300 300 300 300 300
1~ TP - - - - - - - - -
3~ TP 225M 250M 280S 280M 315S 315M 315M 315L 315L
IEC size
1~ TPE - - - - - - - - -
3~ TPE - - - - - - - - -
3~ TP [kW] -/45 -/55 -/75 -/90 -/110 -/132 -/160 -/200 -/250
P2
3~ TPE [kW] - - - - - - - - -
PN PN16/25 PN16/25 PN16/25 PN16/25 PN16/25 PN16/25 PN16/25 PN16/25 PN16/25
Tmin;Tmax [°C] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150] [-40;150]
D1 [mm] 300 300 300 300 300 300 300 300 300
1~/3~ TP [mm] -/442 -/495 -/555 -/555 -/610 -/610 -/610 -/610 -/702
AC
1~/3~ TPE [mm] - - - - - - - - -
1~/3~ TP [mm] -/325 -/392 -/432 -/432 -/495 -/495 -/495 -/495 -/619
AD
1~/3~ TPE [mm] - - - - - - - - -
P [mm] 450 550 550 550 660 660 660 660 660
B1 [mm] 438/- 438/- 438/- 460/- 460/- 460/- 460/- 438/- 438/-
B2 [mm] 320/- 320/- 320/- 345/- 345/- 345/- 345/- 338/- 338/-
B5 [mm] 663 663 663 663 663 663 663 666 666
C3 [mm] 570 570 570 570 570 570 570 570 570
C9 [mm] 1150 1150 1150 1150 1150 1150 1150 1150 1150
L1 [mm] 1240 1240 1240 1240 1240 1240 1240 1240 1240
H1 [mm] 348 348 348 317 317 317 317 340 340
H2 [mm] 423 423 423 443 468 468 468 455 460
H3 [mm] -/1480 -/1588 -/1591 -/1690 -/1717 -/1877 -/1877 -/2027 -/2040
∅ [mm] 20 20 20 20 20 20 20 20 20

189
24
DN 350
4-pole, PN 6, 10, 16, 25
Performance curves and technical data

TP 350-XXX/4

H
[m]
65 -680/4 TP, TPE 350
60 60 Hz
-540/4
55
-450/4
50
45 -400/4

40
35
30
25
20
15
10
0 400 800 1200 1600 Q [m³/h]
P2
[kW]
-680/4
240

200 -540/4

160 -450/4

120 -400/4

80

40
0 400 800 1200 1600 Q [m³/h]
NPSH
[m]

24
-540/4, -680/4

20
-450/4
16
-400/4

12

8
0 400 800 1200 1600 Q [m³/h]
Eta
[%]
90
85
-680/4
80
75 -540/4
-450/4
70
65
-400/4
60
55
50
0 400 800 1200 1600 Q [m³/h]
TM06 6623 4717

0 100 200 300 400 500 Q [l/s]

0 1 2 3 4 5 v [m/s]

190
24
DN 350
4-pole, PN 6, 10, 16, 25

Performance curves and technical data


TM06 6532 1716

Technical data

TP 350 -400/4 -450/4 -540/4 -680/4


TPD - - - -
TPE - - - -
TPED - - - -
Series 300 300 300 300
1~ TP - - - -
3~ TP 315M 315M 315L 315L
IEC size
1~ TPE - - - -
3~ TPE - - - -
3~ TP [kW] -/132 -/160 -/200 -/250
P2
3~ TPE [kW] - - - -
PN PN16/25 PN16/25 PN16/25 PN16/25
Tmin;Tmax [°C] [-40;150] [-40;150] [-40;150] [-40;150]
D1 [mm] 350 350 350 350
1~/3~ TP [mm] -/610 -/610 -/610 -/702
AC
1~/3~ TPE [mm] - - - -
1~/3~ TP [mm] -/495 -/495 -/495 -/619
AD
1~/3~ TPE [mm] - - - -
P [mm] 660 660 660 660
B1 [mm] 521/- 521/- 521/- 521/-
B2 [mm] 373/- 373/- 373/- 373/-
B5 [mm] 735 735 735 735
C3 [mm] 660 660 660 660
C9 [mm] 1310 1310 1310 1310
L1 [mm] 1400 1400 1400 1400
H1 [mm] 361 361 361 361
H2 [mm] 509 509 509 514
H3 [mm] -/1962 -/1962 -/2102 -/2125
∅ [mm] 20 20 20 20

191
25 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

25. Weights and shipping volume


Weights and shipping volume

TPE2, TPE2 D, TPE3, TPE3 D, PN 6, 10, 16


Connection Weights
Shipping volume [m3]
Net [kg] Gross [kg]
Pump type
D1 D D1S TPE2, TPE2 D, TPE2, TPE2 D, TPE2, TPE2 D,
TPE3 TPE3 D TPE3 TPE3 D TPE3 TPE3 D
TPE2, TPE2 D, TPE3, TPE3 D 32-80 DN 32 DN 32 24 44 32 53 0.034 0.104
TPE2, TPE2 D, TPE3, TPE3 D 32-120 DN 32 DN 32 24 44 32 53 0.034 0.104
TPE2, TPE2 D, TPE3, TPE3 D 32-150 DN 32 DN 32 24 44 32 53 0.034 0.104
TPE2, TPE2 D, TPE3, TPE3 D 32-180 DN 32 DN 32 24 44 32 53 0.034 0.104
TPE2, TPE2 D, TPE3, TPE3 D 32-200 DN 32 DN 32 24 44 32 53 0.034 0.104
TPE2, TPE2 D, TPE3, TPE3 D 40-80 DN 40 DN 40 25 46 33 54 0.035 0.105
TPE2, TPE2 D, TPE3, TPE3 D 40-120 DN 40 DN 40 25 46 33 54 0.035 0.105
TPE2, TPE2 D, TPE3, TPE3 D 40-150 DN 40 DN 40 25 46 33 54 0.035 0.105
TPE2, TPE2 D, TPE3, TPE3 D 40-180 DN 40 DN 40 25 46 33 55 0.035 0.105
TPE2, TPE2 D, TPE3, TPE3 D 40-200 DN 40 DN 40 25 46 33 55 0.035 0.105
TPE2, TPE2 D, TPE3, TPE3 D 40-240 DN 40 DN 40 27 49 35 58 0.035 0.105
TPE2, TPE2 D, TPE3, TPE3 D 50-60 DN 50 DN 50 27 49 35 57 0.036 0.109
TPE2, TPE2 D, TPE3, TPE3 D 50-80 DN 50 DN 50 27 49 35 57 0.036 0.109
TPE2, TPE2 D, TPE3, TPE3 D 50-120 DN 50 DN 50 27 49 35 57 0.036 0.109
TPE2, TPE2 D, TPE3, TPE3 D 50-150 DN 50 DN 50 27 49 35 57 0.036 0.109
TPE2, TPE2 D, TPE3, TPE3 D 50-180 DN 50 DN 50 27 49 35 58 0.036 0.109
TPE2, TPE2 D, TPE3, TPE3 D 50-200 DN 50 DN 50 29 52 37 61 0.036 0.109
TPE2, TPE2 D, TPE3, TPE3 D 50-240 DN 50 DN 50 30 54 38 63 0.036 0.109
TPE2, TPE2 D, TPE3, TPE3 D 65-60 DN 65 DN 65 29 52 38 61 0.044 0.117
TPE2, TPE2 D, TPE3, TPE3 D 65-80 DN 65 DN 65 29 52 38 61 0.044 0.117
TPE2, TPE2 D, TPE3, TPE3 D 65-120 DN 65 DN 65 29 52 38 61 0.044 0.117
TPE2, TPE2 D, TPE3, TPE3 D 65-150 DN 65 DN 65 30 54 39 62 0.044 0.117
TPE2, TPE2 D, TPE3, TPE3 D 65-180 DN 65 DN 65 31 56 40 65 0.044 0.117
TPE2, TPE2 D, TPE3, TPE3 D 65-200 DN 65 DN 65 32 57 41 66 0.044 0.117
TPE2, TPE2 D, TPE3, TPE3 D 80-40 DN 80 DN 80 35 60 44 68 0.049 0.129
TPE2, TPE2 D, TPE3, TPE3 D 80-120 DN 80 DN 80 36 61 45 70 0.049 0.129
TPE2, TPE2 D, TPE3, TPE3 D 80-150 DN 80 DN 80 38 65 46 73 0.049 0.129
TPE2, TPE2 D, TPE3, TPE3 D 80-180 DN 80 DN 80 39 67 48 76 0.049 0.129
TPE2, TPE2 D, TPE3, TPE3 D 100-40 DN 100 DN 100 40 68 48 78 0.064 0.168
TPE2, TPE2 D, TPE3, TPE3 D 100-120 DN 100 DN 100 40 70 49 79 0.064 0.168
TPE2, TPE2 D, TPE3, TPE3 D 100-150 DN 100 DN 100 42 73 51 83 0.064 0.168
TPE2, TPE2 D, TPE3, TPE3 D 100-180 DN 100 DN 100 43 76 52 85 0.064 0.168

192
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
25
TP, TPD, TPE, 2-pole, PN 6, 10, 16, 25

Weights and shipping volume


Connection Weights
Shipping volume [m3] ★
Pump type Net [kg] ★ Gross [kg] ★
D1D D1 S
TP/TPD TPE TP/TPD TPE TP/TPD TPE
TP 32-80/2 DN 32 DN 32 17/- - 18/- - 0.04 / - -
TP 32-160/2 DN 32 DN 32 19/- - 20/- - 0.04 / - -
TP 32-220/2 DN 32 DN 32 24/- - 27/- - 0.06 / - -
TP 32-260/2 DN 32 DN 32 26/- - 29/- - 0.06 / - -
TP 32-330/2 DN 32 DN 32 32/- - 35/- - 0.06 / - -
TP, TPD 32-300/2 DN 32 DN 32 58/118 51 64/135 58 0.2176 / 0.3912 0.2176
TP, TPD 32-360/2 DN 32 DN 32 69/125 61 76/142 75 0.2176 / 0.4584 0.390
TP, TPD 32-450/2 DN 32 DN 32 74/150 65 81/167 79 0.2176 / 0.4584 0.390
TP, TPD 32-550/2 DN 32 DN 32 89/180 85 104/197 99 0.2176 / 0.4584 0.390
TP, TPD 32-680/2 DN 32 DN 32 91/184 93 107/201 107 0.2176 / 0.4584 0.390
TP, TPD 32-820/2 DN 32 DN 32 140/283 117 157/313 148 0.7248 / 0.6507 1.120
TP 40-80/2 DN 40 DN 40 19/- - 21/- - 0.04 / - -
TP 40-160/2 DN 40 DN 40 21/- - 25/- - 0.06 / - -
TP 40-240/2 DN 40 DN 40 26/- - 29/- - 0.06 / - -
TP 40-270/2 DN 40 DN 40 38/- - 42/- - 0.06 / - -
TP 40-330/2 DN 40 DN 40 40/- - 44/- - 0.06 / - -
TP 40-390/2 DN 40 DN 40 46/- - 49/- - 0.06 / - -
TP, TPD 40-400/2 DN 40 DN 40 75/156 67 82/186 81 0.2176 / 0.6507 0.390
TP, TPD 40-460/2 DN 40 DN 40 90/186 86 105/203 100 0.2176 / 0.3912 0.390
TP, TPD 40-530/2 DN 40 DN 40 92/190 92 107/207 106 0.2176 / 0.3912 0.390
TP, TPD 40-690/2 DN 40 DN 40 140/289 119 157/319 150 0.7248 / 0.6507 1.120
TP, TPD 40-820/2 DN 40 DN 40 152/312 178 169/342 199 0.7248 / 0.6507 0.7248
TP, TPD 40-920/2 DN 40 DN 40 162/332 202 179/362 224 0.7248 / 0.6507 0.7248
TP 50-80/2 DN 50 DN 50 24/- - 26/- - 0.04 / - -
TP 50-160/2 DN 50 DN 50 28/- - 31/- - 0.06 / - -
TP 50-240/2 DN 50 DN 50 35/- - 38/- - 0.15 / - -
TP, TPD 50-250/2 DN 50 DN 50 53/109 - 59/126 - 0.184 / 0.4584 -
TP, TPD 50-300/2 DN 50 DN 50 65/116 58 70/133 66 0.184 / 0.4584 0.180
TP, TPD 50-350/2 DN 50 DN 50 71/144 61 76/161 69 0.184 / 0.4584 0.180
TP, TPD 50-410/2 DN 50 DN 50 85/174 81 101/191 95 0.184 / 0.4584 0.390
TP, TPD 50-430/2 DN 50 DN 50 99/204 100 114/224 114 0.2176 / 0.518 0.390
TP, TPD 50-530/2 DN 50 DN 50 147/302 126 164/332 157 0.7248 / 0.6507 1.120
TP, TPD 50-640/2 DN 50 DN 50 165/333 198 195/357 228 0.58 / 0.64 0.580
TP, TPD 50-720/2 DN 50 DN 50 158/324 184 175/354 206 0.7248 / 0.6507 0.7248
TP, TPD 50-790/2 DN 50 DN 50 168/345 209 185/375 230 0.7248 / 0.6507 0.7248
TP, TPD 50-880/2 DN 50 DN 50 198/403 222 216/453 243 0.7248 / 1.524 0.7248
TP, TPD 50-1050/2 DN 50 DN 50 352/713 - 370/763 - 0.7248 / 1.524 -
TP 65-80/2 DN 65 DN 65 29/- - 32/- - 0.06 / 1.524 -
TP 65-160/2 DN 65 DN 65 37/- - 41/- - 0.08 / - -
TP 65-240/2 DN 65 DN 65 39/- - 43/- - 0.08 / - -
TP, TPD 65-200/2 DN 65 DN 65 68/126 62 73/143 70 0.184 / 0.4584 0.180
TP, TPD 65-250/2 DN 65 DN 65 73/151 65 78/168 73 0.184 / 0.2632 0.180
TP, TPD 65-340/2 DN 65 DN 65 88/179 85 104/196 99 0.184 / 0.2632 0.390
TP, TPD 65-390/2 DN 65 DN 65 90/182 91 105/199 105 0.184 / 0.4584 0.390
TP, TPD 65-480/2 DN 65 DN 65 148/309 127 165/339 158 0.7248 / 0.6507 1.120
TP, TPD 65-540/2 DN 65 DN 65 160/331 229 177/361 251 0.7248 / 0.6507 0.7248
TP, TPD 65-630/2 DN 65 DN 65 170/352 241 187/382 263 0.7248 / 0.6507 0.7248
TP, TPD 65-740/2 DN 65 DN 65 199/410 222 218/460 241 0.7248 / 1.524 0.7248
TP, TPD 65-910/2 DN 65 DN 65 344/701 - 363/751 - 0.7248 / 1.524 -
TP, TPD 65-920/2 DN 65 DN 65 336/679 - 342/787 - 0.580 / 1.800 -
TP, TPD 65-1050/2 DN 65 DN 65 361/734 - 380/784 - 0.7248 / 1.524 -
TP 80-160/2 DN 80 DN 80 52/- - 57/- - 0.15 / - -
TP, TPD 80-200/2 DN 80 DN 80 78/157 67 90/174 75 0.184 / 0.4584 0.180
TP, TPD 80-240/2 DN 80 DN 80 93/187 87 105/204 101 0.184 / 0.4584 0.390
TP, TPD 80-290/2 DN 80 DN 80 95/191 93 107/208 107 0.184 / 0.4584 0.390
TP, TPD 80-330/2 DN 80 DN 80 151/307 126 172/337 157 0.7248 / 1.524 1.120
TP, TPD 80-400/2 DN 80 DN 80 162/329 187 182/359 208 0.7248 / 1.524 0.7248
TP, TPD 80-480/2 DN 80 DN 80 178/351 217 199/381 238 0.7248 / 1.524 0.7248
TP, TPD 80-530/2 DN 80 DN 80 207/409 230 228/459 251 0.7248 / 1.524 0.7248
TP, TPD 80-640/2 DN 80 DN 80 359/713 - 380/344 - 0.7248 / 1.524 -
TP, TPD 80-750/2 DN 80 DN 80 369/722 - 389/764 - 0.7248 / 1.524 -

193
25 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Weights and shipping volume

Connection Weights
Shipping volume [m3] ★
Pump type Net [kg] ★ Gross [kg] ★
D1D D1 S
TP/TPD TPE TP/TPD TPE TP/TPD TPE
TP, TPD 100-230/2 DN 100 DN 100 110/230 108 124/280 139 0.7248 / 1.524 1.120
TP, TPD 100-300/2 DN 100 DN 100 155/319 133 177/369 164 0.7248 / 1.524 1.120
TP, TPD 100-370/2 DN 100 DN 100 168/344 193 190/394 214 0.9696 / 1.524 0.9696
TP, TPD 100-350/2 DN 100 DN 100 200/394 238 201/445 240 0.7248 / 1.524 0.7248
TP, TPD 100-380/2 DN 100 DN 100 230/455 252 231/505 254 0.9696 / 1.524 0.9696
TP, TPD 100-530/2 DN 100 DN 100 389/775 - 430/833 - 0.7973 / 1.800 -
TP, TPD 100-630/2 DN 100 DN 100 405/808 - 447/865 - 0.7973 / 1.800 -
TP, TPD 100-700/2 DN 100 DN 100 428/854 - 444/927 - 0.7973 / 1.800 -
TP 100-760/2 DN 100 DN 100 775/- - 895/- - 2.05 / - -
TP 100-940/2 DN 100 DN 100 874/- - 994/- - 2.05 / - -
TP 100-1040/2 DN 100 DN 100 1065/- - 1185/- - 2.05 / - -
TP 100-1200/2 DN 100 DN 100 1220/- - 1340/- - 2.05 / - -
TP 100-1360/2 DN 100 DN 100 1360/- - 1480/- - 2.05 / - -
TP 100-1510/2 DN 100 DN 100 1560/- - 1680/- - 2.05 / - -

★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

TP, TPD, TPE, 4-pole, PN 6, 10, 16, 25


Connection Weights
Shipping volume [m 3] ★
Pump type Net [kg] ★ Gross [kg] ★
D1D D1S
TP/TPD TPE TP/TPD TPE TP/TPD TPE
TP 32-40/4 DN 32 DN 32 26/- - 29/- - 0.04 / - -
TP 32-80/4 DN 32 DN 32 26/- - 29/- - 0.04 / - -
TP, TPD 32-120/4 DN 32 DN 32 46/94 - 52/111 - 0.1632 / 0.3912 -
TP, TPD 32-140/4 DN 32 DN 32 47/97 - 53/114 - 0.1632 / 0.3912 -
TP, TPD 32-190/4 DN 32 DN 32 53/116 - 59/134 - 0.2176 / 0.3912 -
TP 40-40/4 DN 40 DN 40 20/- - 22/- - 0.04 / - -
TP 40-80/4 DN 40 DN 40 25/- - 28/- - 0.06 / - -
TP, TPD 40-110/4 DN 40 DN 40 48/102 - 54/119 - 0.1632 / 0.4584 -
TP, TPD 40-150/4 DN 40 DN 40 54/122 - 60/152 - 0.2176 / 0.4584 -
TP, TPD 40-180/4 DN 40 DN 40 57/129 - 63/146 - 0.1632 / 0.4584 -
TP, TPD 40-230/4 DN 40 DN 40 67/145 - 73/162 - 0.2176 / 0.4584 -
TP 50-40/4 DN 50 DN 50 22/- - 25/- - 0.04 / - -
TP 50-80/4 DN 50 DN 50 27/- - 30/- - 0.06 / - -
TP, TPD 50-100/4 DN 50 DN 50 55/118 - 61/137 - 0.16 / 0.497 -
TP, TPD 50-115/4 DN 50 DN 50 62/137 - 68/157 - 0.2176 / 0.5184 -
TP, TPD 50-130/4 DN 50 DN 50 64/144 - 70/163 - 0.2176 / 0.5184 -
TP, TPD 50-180/4 DN 50 DN 50 78/162 - 92/182 - 0.39 / 0.52 -
TP, TPD 50-240/4 DN 50 DN 50 79/167 77 86/186 91 0.2176 / 0.5184 0.390
TP, TPD 50-270/4 DN 50 DN 50 78/194 80 84/213 94 0.2176 / 0.5184 0.390
TP, TPD 50-340/4 DN 50 DN 50 112/230 106 127/250 120 0.2176 / 0.5184 0.390
TP 65-40/4 DN 65 DN 65 32/- - 35/- - 0.06 / - -
TP 65-80/4 DN 65 DN 65 41/- - 44/- - 0.08 / - -
TP, TPD 65-130/4 DN 65 DN 65 66/150 - 72/167 - 0.2176 / 0.4584 -
TP, TPD 65-150/4 DN 65 DN 65 75/166 - 82/183 - 0.2176 / 0.4584 -
TP, TPD 65-190/4 DN 65 DN 65 81/173 76 87/190 90 0.2176 / 0.4584 0.390
TP, TPD 65-230/4 DN 65 DN 65 79/202 80 86/217 94 0.2176 / 0.4584 0.390
TP, TPD 65-310/4 DN 65 DN 65 113/237 106 130/267 120 0.7248 / 0.4584 0.390
TP, TPD 65-330/4 DN 65 DN 65 124/258 111 141/288 125 0.7248 / 0.6507 0.390
TP 80-40/4 DN 80 DN 80 49/- - 52/- - 0.08 / - -
TP 80-80/4 DN 80 DN 80 45/- - 49/- - 0.08 / - -
TP, TPD 80-110/4 DN 80 DN 80 79/165 - 92/182 - 0.2176 / 0.4584 -
TP, TPD 80-150/4 DN 80 DN 80 94/185 81 108/204 95 0.2176 / 0.5184 0.390
TP, TPD 80-170/4 DN 80 DN 80 101/199 85 115/119 99 0.2176 / 0.6507 0.390
TP, TPD 80-230/4 DN 80 DN 80 182/369 168 184/419 199 0.9696 / 1.524 1.120
TP, TPD 80-280/4 DN 80 DN 80 192/390 175 194/440 206 0.9696 / 1.524 1.120
TP, TPD 80-340/4 DN 80 DN 80 225/452 238 227/502 240 0.9696 / 1.524 0.9696
TP, TPD 80-410/4 DN 80 DN 80 240/474 258 242/525 278 0.9696 / 1.524 0.9696
TP, TPD 80-460/4 DN 80 DN 80 298/590 297 300/622 315 0.9696 / 1.524 0.9696
TP, TPD 80-510/4 DN 80 DN 80 316/634 - 318/666 - 0.9696 / 1.524 -

194
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
25

Weights and shipping volume


Connection Weights
Shipping volume [m 3] ★
Pump type Net [kg] ★ Gross [kg] ★
D1D D1S
TP/TPD TPE TP/TPD TPE TP/TPD TPE
TP 100-40/4 DN 100 DN 100 54/- - 59/- - 0.151 / - -
TP 100-80/4 DN 100 DN 100 61/- - 67/- - 0.191 / - -
TP, TPD 100-100/4 DN 100 DN 100 114/230 101 117/280 115 0.7248 / 1.524 0.390
TP, TPD 100-130/4 DN 100 DN 100 140/282 123 142/333 137 0.7248 / 1.524 0.390
TP, TPD 100-150/4 DN 100 DN 100 148/337 129 164/420 160 0.390 / 1.520 1.120
TP, TPD 100-170/4 DN 100 DN 100 157/316 146 158/367 177 0.7248 / 1.524 1.120
TP, TPD 100-200/4 DN 100 DN 100 232/484 208 234/534 239 0.9696 / 1.524 1.120
TP, TPD 100-240/4 DN 100 DN 100 264/544 276 266/594 293 0.9696 / 1.524 1.120
TP, TPD 100-260/4 DN 100 DN 100 220/323 226 238/406 244 0.960 / 1.520 0.960
TP, TPD 100-290/4 DN 100 DN 100 275/567 293 278/617 313 0.9696 / 1.524 0.9696
TP, TPD 100-340/4 DN 100 DN 100 333/682 332 375/732 352 0.9696 / 1.524 0.9696
TP, TPD 100-350/4 DN 100 DN 100 396/720 - 414/828 - 0.960 / 1.800 -
TP, TPD 100-390/4 DN 100 DN 100 349/714 - 366/746 - 0.9696 / 1.524 0.9696
TP, TPD 100-470/4 DN 100 DN 100 440/896 - 457/909 - 0.9696 / 1.800 -
TP 100-560/4 DN 100 DN 100 550/- - 575/- - 1.524/- -
TP 125-80/4 DN 125 DN 125 129/- 127 148/- 158 0.969 / - 1.120
TP 125-110/4 DN 125 DN 125 144/- 130 163/- 161 0.969 / - 1.120
TP 125-135/4 DN 125 DN 125 150/- 152 169/- 183 0.969 / - 1.120
TP, TPD 125-130/4 DN 125 DN 125 203/432 186 223/482 217 0.9696 / 1.524 1.120
TP, TPD 125-160/4 DN 125 DN 125 213/454 193 234/504 224 0.9696 / 1.524 1.120
TP, TPD 125-200/4 DN 125 DN 125 254/541 260 285/649 291 0.96 / 1.8 0.960
TP, TPD 125-230/4 DN 125 DN 125 264/597 326 281/705 343.2 0.960 / 1.520 0.960
TP 125-220/4 DN 125 DN 125 322/- 344 422/- 445 1.12 / - 1.12
TP, TPD 125-280/4 DN 125 DN 125 357/723 359 458/754 460 1.12 / 1.8 1.12
TP, TPD 125-340/4 DN 125 DN 125 371/750 - 471/782 - 1.32 / 1.8 -
TP, TPD 125-365/4 DN 125 DN 125 431/871 - 532/902 - 1.32 / 1.8 -
TP, TPD 125-420/4 DN 125 DN 125 464/933 - 485/990 - 1.524 / 1.800 -
TP, TPD 125-480/4 DN 125 DN 125 509/1021 - 509/1035 - 1.524 / 1.800 -
TP 125-550/4 DN 125 DN 125 550/- - 575/- - 1.524/- -
TP 125-580/4 DN 125 DN 125 690/- - 715/- - 1.524/- -
TP 150-130/4 DN 150 DN 150 241/- 260/- 414/- 433/- 2.3 /- 2.3 /-
TP 150-160/4 DN 150 DN 150 267/- 286/- 440/- 460/- 2.3 /- 2.3 /-
TP 150-200/4 DN 150 DN 150 286/- 289/- 459/- 462/- 2.3 /- 2.3 /-
TP 150-220/4 DN 150 DN 150 309/- - 482/- - 2.3 /- -
TP, TPD 150-180/4 DN 150 DN 150 321/641 339 341/692 359 0.9696 / 1.524 0.9696
TP, TPD 150-210/4 DN 150 DN 150 380/759 378 400/816 398 0.9696 / 1.800 0.9696
TP, TPD 150-240/4 DN 150 DN 150 395/790 - 416/847 - 0.9696 / 1.800 0.9696
TP, TPD 150-300/4 DN 150 DN 150 485/969 - 505/1026 - 1.524 / 1.800 -
TP, TPD 150-340/4 DN 150 DN 150 415/1085 - 512/1193 - 1.800 / 1.800 -
TP 150-360/4 DN 150 DN 150 477/- - 632/- - 2.3 / - -
TP 150-380/4 DN 150 DN 150 520/- - 675/- - 2.3 / - -
TP 150-400/4 DN 150 DN 150 554/- - 709/- - 2.3 / - -
TP 150-420/4 DN 150 DN 150 560/- - 715 - 2.3 / - -
TP 150-440/4 DN 150 DN 150 672/- - 870/- - 3.1 / - -
TP 150-480/4 DN 150 DN 150 827/- - 1025/- - 3.1 / - -
TP 150-490/4 DN 150 DN 150 690/- - 845 - 2.3 / - -
TP 150-550/4 DN 150 DN 150 805/- - 990 - 3.1 / - -
TP 150-610/4 DN 150 DN 150 942/- - 1140/- - 3.1 / - -
TP 150-700/4 DN 150 DN 150 1042/- - 1275/- - 4.6 / - -
TP 150-810/4 DN 150 DN 150 1215/- - 1448/- - 4.6 / - -
TP 150-960/4 DN 150 DN 150 1370/- - 1603/- - 4.6 / - -

195
25 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Weights and shipping volume

Connection Weights
Shipping volume [m 3] ★
Pump type Net [kg] ★ Gross [kg] ★
D1D D1S
TP/TPD TPE TP/TPD TPE TP/TPD TPE
TP 200-80/4 DN 200 DN 200 322/- 282 495/- 437 2.3 / - 2.3
TP 200-110/4 DN 200 DN 200 343/- 362 516/- 535 2.3 / - 2.3
TP 200-140/4 DN 200 DN 200 369/- 388 542/- 561 2.3 / - 2.3
TP 200-190/4 DN 200 DN 200 389/- 392 562/- 565 2.3 / - 2.3
TP 200-210/4 DN 200 DN 200 412/- - 585/- - 2.3 / - -
TP 200-250/4 DN 200 DN 200 480/- - 678/- - 3.1 / - -
TP 200-280/4 DN 200 DN 200 578/- - 776/- - 3.1 / - -
TP 200-320/4 DN 200 DN 200 618/- - 816/- - 3.1 / - -
TP 200-360/4 DN 200 DN 200 760/- - 993/- - 4.6 / - -
TP 200-390/4 DN 200 DN 200 875/- - 1098/- - 4.6 / - -
TP 200-400/4 DN 200 DN 200 1028/- - 1133/- - 3.1 / - -
TP 200-430/4 DN 200 DN 200 925/- - 1110/- - 3.1 / - -
TP 200-440/4 DN 200 DN 200 1049/- - 1269/- - 4.6 / - -
TP 200-490/4 DN 200 DN 200 1043/- - 1228/- - 3.1 / - -
TP 200-500/4 DN 200 DN 200 1229/- - 1449/- - 4.6 / - -
TP 200-540/4 DN 200 DN 200 1144/- - 1364/- - 4.6 / - -
TP 200-600/4 DN 200 DN 200 1325/- - 1563/- - 4.6 / - -
TP 200-680/4 DN 200 DN 200 1500/- - 1720/- - 4.6 / - -
TP 200-770/4 DN 200 DN 200 1642/- - 1862/- - 4.6 / - -
TP 300-230/4 DN 300 DN 300 905/- - 1035/- - 2.82 / - -
TP 300-270/4 DN 300 DN 300 1065/- - 1195/- - 2.82 / - -
TP 300-360/4 DN 300 DN 300 1175/- - 1305/- - 2.82 / - -
TP 300-370/4 DN 300 DN 300 1330/- - 1490/- - 3.24 / - -
TP 300-440/4 DN 300 DN 300 1510/- - 1670/- - 3.24 / - -
TP 300-550/4 DN 300 DN 300 1665/- - 1825/- - 3.24 / - -
TP 300-630/4 DN 300 DN 300 1805/- - 1965/- - 3.24 / - -
TP 300-640/4 DN 300 DN 300 1965/- - 2285/- - 6.06 / - -
TP 300-750/4 DN 300 DN 300 2155/- - 2475/- - 6.46 / - -
TP 350-400/4 DN 350 DN 350 1865/- - 2115/- - 5.26 / - -
TP 350-450/4 DN 350 DN 350 2005/- - 2255/- - 5.26 / - -
TP 350-540/4 DN 350 DN 350 2210/- - 2530/- - 6.46 / - -
TP 350-680/4 DN 350 DN 350 2405/- - 2725/- - 6.46 / - -

★ The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

196
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
26

26. Minimum efficiency index

Minimum efficiency index


Minimum efficiency index, MEI, means the dimensionless scale unit for hydraulic pump efficiency at best efficiency
point, part load and overload. The Commission Regulation, EU, sets efficiency requirements to MEI greater than or
equal to 0.10 as from 1 January 2013 and MEI greater than or equal to 0.40 as from 1 January 2015. An indicative
benchmark for best-performing water pump available on the market as from 1 January 2013 is determined in the
regulation.
• The benchmark for most efficient water pumps is MEI greater than or equal to 0.70.
• The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter.
The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The
minimum efficiency index, MEI, is based on the full impeller diameter.
• The operation of this water pump with variable duty points may be more efficient and economic when controlled, for
example, by the use of a variable-speed drive that matches the pump duty to the system.
• Information on benchmark efficiency is available at http://europump.eu/efficiencycharts.

TPE2, TPE2 D, TPE3, TPE3 D


P2 Nominal impeller size /
TPE2, TPE3 Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TPE2, TPE2 D, TPE3, TPE3 D All ● ≥ 0.70

TP, TPD, TPE, 2-pole, PN 6, 10, 16


P2 Nominal impeller size /
TP Series 200, 2-pole Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TP 32-80/2 0.37 ● ≥ 0.60
TP 32-160/2 0.55 ● ≥ 0.70
TP 32-220/2 0.75 32-136 / 111 ●
TP 32-260/2 1.1 32-136 / 118 ● ≥ 0.40
TP 32-330/2 1.5 32-136 / 136 ●
TP 40-80/2 0.55 ● ≥ 0.49
TP 40-160/2 0.75 ● ≥ 0.70
TP 40-240/2 1.1 ● ≥ 0.70
TP 40-270/2 1.5 ● ≥ 0.53
TP 40-330/2 2.2 ● ≥ 0.43
TP 40-390/2 3.0 ● ≥ 0.66
TP 50-80/2 0.55 ● ≥ 0.70
TP 50-160/2 1.1 ● ≥ 0.56
TP 50-240/2 1.5 ● ≥ 0.70
TP 65-80/2 1.1 ● ≥ 0.64
TP 65-160/2 1.5 ● ≥ 0.70
TP 65-240/2 2.2 ● ≥ 0.70
TP 80-160/2 3.0 ● ≥ 0.70

P2 Nominal impeller size /


TP Series 300, 2-pole Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TP, TPD, TPE 32-300/2 2.2 32-200.1 / 137 ●
TP, TPD, TPE 32-360/2 3 32-200.1 / 148 ●
TP, TPD, TPE 32-450/2 4 32-200.1 / 160 ●
≥ 0.46
TP, TPD, TPE 32-550/2 5.5 32-200.1 / 174 ●
TP, TPD, TPE 32-680/2 7.5 32-200.1 / 191 ●
TP, TPD, TPE 32-820/2 11 32-200.1 / 205 ●
TP, TPD, TPE 40-400/2 4 32-200 / 150 ●
TP, TPD, TPE 40-460/2 5.5 32-200 / 162 ●
TP, TPD, TPE 40-530/2 7.5 32-200 / 176 ●
≥ 0.70
TP, TPD, TPE 40-690/2 11 32-200 / 194 ●
TP, TPD, TPE 40-820/2 15 32-200 / 208 ●
TP, TPD, TPE 40-920/2 18.5 32-200 / 219 ●
TP, TPD 50-250/2 2.2 32-125 / 113 ●
≥ 0.70
TP, TPD, TPE 50-300/2 3 32-125 / 123 ●
TP, TPD, TPE 50-350/2 4 32-160 / 137 ●
≥ 0.40
TP, TPD, TPE 50-410/2 5.5 32-160 / 146 ●
TP, TPD, TPE 50-430/2 7.5 40-200 / 161 ●
TP, TPD, TPE 50-530/2 11 40-200 / 176 ● ≥ 0.57
TP, TPD, TPE 50-640/2 15 40-200 / 188 ●

197
26 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Minimum efficiency index

P2 Nominal impeller size /


TP Series 300, 2-pole Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TP, TPD, TPE 50-720/2 15 40-250 / 184 ●
TP, TPD, TPE 50-790/2 18.5 40-250 / 204 ●
≥ 0.60
TP, TPD, TPE 50-880/2 22 40-250 / 213 ●
TP, TPD 50-1050/2 30 40-250 / 232 ●
TP, TPD, TPE 65-200/2 3 40-125 / 107 ●
≥ 0.70
TP, TPD, TPE 65-250/2 4 40-125 / 118 ●
TP, TPD, TPE 65-340/2 5.5 40-160 / 133 ●
≥ 0.54
TP, TPD, TPE 65-390/2 7.5 40-160 / 145 ●
TP, TPD, TPE 65-480/2 11 50-200 / 157 ●
TP, TPD, TPE 65-540/2 15 50-200 / 170 ●
≥ 0.52
TP, TPD, TPE 65-630/2 18.5 50-200 / 180 ●
TP, TPD 65-920/2 37 50-200 / 219 ●
TP, TPD, TPE 65-740/2 22 50-250 / 196 ●
TP, TPD 65-910/2 30 50-250 / 215 ● ≥ 0.48
TP, TPD 65-1050/2 37 50-250 / 230 ●
TP, TPD, TPE 80-200/2 4 50-125 / 105 ●
TP, TPD, TPE 80-240/2 5.5 50-125 / 115 ● ≥ 0.53
TP, TPD, TPE 80-290/2 7.5 50-125 / 127 ●
TP, TPD, TPE 80-330/2 11 65-160 / 137 ●
≥ 0.44
TP, TPD, TPE 80-400/2 15 65-160 / 149 ●
TP, TPD, TPE 80-480/2 18.5 65-200 / 160 ●
TP, TPD, TPE 80-530/2 22 65-200 / 167 ●
≥ 0.65
TP, TPD 80-640/2 30 65-200 / 184 ●
TP, TPD 80-750/2 37 65-200 / 197 ●
TP, TPD, TPE 100-230/2 7.5 65-125 / 120-110 ●
TP, TPD, TPE 100-300/2 11 65-125 / 130 ● ≥ 0.60
TP, TPD, TPE 100-370/2 15 65-125 / 141 ●
TP, TPD, TPE 100-350/2 18.5 80-160 / 147-127 ●
≥ 0.70
TP, TPD, TPE 100-380/2 22 80-160 / 151-133 ●
TP, TPD 100-530/2 30 80-200 / 166 ●
TP, TPD 100-630/2 37 80-200 / 180 ● ≥ 0.50
TP, TPD 100-700/2 45 80-200 / 190 ●

TP, TPD, TPE, 4-pole, PN 6, 10, 16


P2 Nominal impeller size /
TP Series 200, 4-pole Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TP 32-40/4 0.12 ● ≥ 0.70
TP 32-80/4 0.25 ● ≥ 0.70
TP 40-40/4 0.25 ● ≥ 0.70
TP 40-80/4 0.55 ● ≥ 0.69
TP 50-40/4 0.25 ● ≥ 0.70
TP 50-80/4 0.55 ● ≥ 0.70
TP 65-40/4 0.37 ● ≥ 0.70
TP 65-80/4 1.1 ● ≥ 0.70
TP 80-40/4 0.75 ● ≥ 0.70
TP 80-80/4 1.5 ● ≥ 0.70
TP 100-40/4 1.1 ● ≥ 0.45
TP 100-80/4 2.2 ● ≥ 0.40

P2 Nominal impeller size /


TP Series 300, 4-pole Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TP, TPD, TPE 32-120/4 0.55 32-200.1 / 168 ●
TP, TPD, TPE 32-140/4 0.75 32-200.1 / 180 ● ≥ 0.70
TP, TPD 32-190/4 1.1 32-200.1 / 203 ●
TP, TPD 40-110/4 0.75 32-200 / 165 ●
TP, TPD 40-150/4 1.1 32-200 / 180 ●
≥ 0.70
TP, TPD 40-180/4 1.5 32-200 / 194 ●
TP, TPD 40-230/4 2.2 32-200 / 219 ●
TP, TPD 50-100/4 0.75 40-200 / 155 ●
TP, TPD 50-115/4 1.1 40-200 / 167 ●
≥ 0.70
TP, TPD 50-130/4 1.5 40-200 / 181 ●
TP, TPD 50-180/4 2.2 40-200 / 206 ●
TP, TPD, TPE 50-240/4 3 40-250 / 224 ●
TP, TPD, TPE 50-270/4 4 40-250 / 240 ● ≥ 0.44
TP, TPD, TPE 50-340/4 5.5 40-250 / 260 ●

198
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
26

Minimum efficiency index


P2 Nominal impeller size /
TP Series 300, 4-pole Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TP, TPD 65-130/4 1.5 50-200 / 164 ●
TP, TPD 65-150/4 2.2 50-200 / 180 ● ≥ 0.55
TP, TPD, TPE 65-190/4 3 50-200 / 200 ●
TP, TPD, TPE 65-230/4 4 50-250 / 220 ●
TP, TPD, TPE 65-310/4 5.5 50-250 / 250 ● ≥ 0.70
TP, TPD, TPE 65-330/4 7.5 50-250 / 263 ●
TP, TPD 80-110/4 2.2 65-160 / 157 ● ≥ 0.51
TP, TPD, TPE 80-150/4 3 65-200 / 174 ●
≥ 0.62
TP, TPD, TPE 80-170/4 4 65-200 / 190 ●
TP, TPD, TPE 80-230/4 5.5 65-250 / 220 ●
≥ 0.41
TP, TPD, TPE 80-280/4 7.5 65-250 / 240 ●
TP, TPD, TPE 80-340/4 11 65-315 / 265 ●
TP, TPD, TPE 80-410/4 15 65-315 / 288 ●
≥ 0.70
TP, TPD, TPE 80-460/4 18.5 65-315 / 305 ●
TP, TPD 80-510/4 22 65-315 / 320 ●
TP, TPD, TPE 100-100/4 3 80-160 / 151 ●
≥ 0.70
TP, TPD, TPE 100-150/4 5.5 80-160 / 177 ●
TP, TPD, TPE 100-130/4 4 80-200 / 172 ●
TP, TPD, TPE 100-170/4 5.5 80-200 / 190 ● ≥ 0.70
TP, TPD, TPE 100-260/4 11 80-200 / 222 ●
TP, TPD, TPE 100-200/4 7.5 80-250 / 202 ●
TP, TPD, TPE 100-240/4 11 80-250 / 226 ● ≥ 0.63
TP, TPD 100-350/4 22 80-250 / 270 ●
TP, TPD, TPE 100-290/4 15 80-315 / 248 ●
TP, TPD, TPE 100-340/4 18.5 80-315 / 267 ●
≥ 0.59
TP, TPD 100-390/4 22 80-315 / 285 ●
TP, TPD 100-470/4 30 80-315 / 310 ●
TP 100-560/4 37 80-315 / 334 ● ≥ 0.60
TP, TPE 125-80/4 3.0 100-160 / 160-124 ●
TP, TPE 125-110/4 4.0 100-160 / 161 ● ≥ 0.70
TP, TPE 125-135/4 5.5 100-160 / 174 ●
TP, TPD, TPE 125-130/4 5.5 100-200 / 168 ●
TP, TPD, TPE 125-160/4 7.5 100-200 / 183 ●
≥ 0.67
TP, TPD, TPE 125-200/4 11 100-200 / 205 ●
TP, TPD, TPE 125-230/4 15 100-200 / 217 ●
TP, TPE 125-220/4 15 100-250 / 219 ●
TP, TPD, TPE 125-280/4 18.5 100-250 / 238 ●
≥ 0.70
TP, TPD 125-340/4 22 100-250 / 256 ●
TP, TPD 125-365/4 30 100-250 / 269 ●
TP, TPD 125-420/4 30 100-315 / 290 ●
TP, TPD 125-480/4 37 100-315 / 309 ●
≥ 0.60
TP 125-550/4 45 100-315 / 329 ●
TP 125-580/4 55 100-315 / 334 ●
TP, TPE 150-130/4 11 125-200 / 180-160 ●
TP, TPE 150-160/4 15 125-200 / 196-188 ●
≥ 0.70
TP, TPE 150-200/4 18.5 125-200 / 218 ●
TP 150-220/4 22 125-200 / 226 ●
TP, TPD, TPE 150-180/4 15 125-250 / 204 ●
TP, TPD, TPE 150-210/4 18.5 125-250 / 216 ●
TP, TPD 150-240/4 22 125-250 / 228 ● ≥ 0.70
TP, TPD 150-300/4 30 125-250 / 247 ●
TP, TPD 150-340/4 37 125-250 / 265 ●
TP 150-360/4 30 125-315 / 270 ●
≥ 0.70
TP 150-400/4 37 125-315 / 286 ●
TP 150-440/4 45 125-400 / 293 ●
TP 150-480/4 55 125-400 / 306 ●
TP 150-610/4 75 125-400 / 345 ●
≥ 0.70
TP 150-700/4 90 125-400 / 369 ●
TP 150-810/4 110 125-400 / 395 ●
TP 150-960/4 132 125-400 / 434 ●
TP, TPE 200-80/4 7.5 150-200 / 191-121 ●
TP, TPE 200-110/4 11 150-200 / 200-138 ●
TP, TPE 200-140/4 15 150-200 / 210-166 ● ≥ 0.70
TP, TPE 200-190/4 18.5 150-200 / 218-206 ●
TP 200-210/4 22 150-200 / 224 ●

199
26 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Minimum efficiency index

P2 Nominal impeller size /


TP Series 300, 4-pole Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TP 200-250/4 30 150-250 / 232 ●
TP 200-280/4 37 150-250 / 245 ●
TP 200-320/4 45 150-250 / 262 ● ≥ 0.70
TP 200-360/4 55 150-250 / 273 ●
TP 200-390/4 75 150-250 / 286 ●
TP 200-270/4 37 150-315 / 242 ●
TP 200-290/4 45 150-315 / 255 ●
TP 200-330/4 55 150-315 / 267 ●
≥ 0.70
TP 200-400/4 75 150-315 / 290 ●
TP 200-440/4 90 150-315 / 305 ●
TP 200-500/4 110 150-315 / 322 ●
TP 200-430/4 55 150-400 / 299 ●
TP 200-490/4 75 150-400 / 322 ●
TP 200-540/4 90 150-400 / 337 ●
≥ 0.70
TP 200-600/4 110 150-400 / 355 ●
TP 200-680/4 132 150-400 / 374 ●
TP 200-770/4 160 150-400 / 394 ●
TP 300-230/4 45 250-315 / 233 ●
TP 300-270/4 55 250-315 / 254 ● ≥ 0.70
TP 300-360/4 75 250-315 / 282 ●
TP 300-370/4 90 250-350 / 301 ●
TP 300-440/4 110 250-350 / 327 ●
≥ 0.70
TP 300-550/4 132 250-350 / 353 ●
TP 300-630/4 160 250-350 / 370 ●
TP 300-640/4 200 250-400 / 363 ●
≥ 0.70
TP 300-750/4 250 250-400 / 392 ●
TP 350-400/4 132 300-350 / 308 ●
TP 350-450/4 160 300-350 / 328 ●
≥ 0.70
TP 350-540/4 200 300-350 / 347 ●
TP 350-680/4 250 300-350 / 367 ●

TP, PN 25
P2 Nominal impeller size /
PN 25 Trimmed impeller Maximum impeller MEI
[kW] actual impeller size
TP Series 300, PN 25 All *

* Not in MEI classification because PN 25 is not a part of the MEI classification.

200
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27

27. Accessories

Accessories
Counterflanges
A flange kit consists of two steel flanges, two gaskets of asbestos-free material IT 200, and the requisite number of
bolts.

Pipe Product
Counterflange Pump type Description Rated pressure
connection number

Threaded 10 bar, EN 1092-2 Rp 1 1/4 539703

ø19
Rp 1¼ 32 mm,
For welding 10 bar, EN 1092-2 539704
nominal
TP, TPE 32
TPD 32

TM03 0478 5204


Threaded 16 bar, EN 1092-2 Rp 1 1/4 539703
ø78
ø100
Threaded For welding 32 mm,
ø140 For welding 16 bar, EN 1092-2 539704
nominal

Threaded 10 bar, EN 1092-2 Rp 1 1/2 539701


ø19
Rp 1½

40 mm,
For welding 10 bar, EN 1092-2 539702
nominal
TP, TPE 40
TPD 40
TM03 0479 5204

ø88 Threaded 16 bar, EN 1092-2 Rp 1 1/2 539701


ø110
Threaded For welding
ø150
40 mm,
For welding 16 bar, EN 1092-2 539702
nominal

Threaded 10 bar, EN 1092-2 Rp 2 549801


ø19
Rp 2
50 mm,
For welding 10 bar, EN 1092-2 549802
nominal
TP, TPE 50
TPD 50
TM03 0480 5204

Threaded 16 bar, EN 1092-2 Rp 2 549801


ø102
ø125
Threaded For welding ø165
50 mm,
For welding 16 bar, EN 1092-2 549802
nominal

Threaded 10 bar, EN 1092-2 Rp 2 1/2 559801


ø19
Rp 2½
65 mm,
For welding 10 bar, EN 1092-2 559802
nominal
TP, TPE 65
TPD 65
TM03 0481 5204

ø122
Threaded 16 bar, EN 1092-2 Rp 2 1/2 559801
ø145
Threaded For welding ø185
65 mm,
For welding 16 bar, EN 1092-2 559802
nominal

Threaded 6 bar, EN 1092-2 Rp 3 569902

80 mm,
For welding 6 bar, EN 1092-2 569901
nominal
Rp 3 ø19

Threaded 10 bar, EN 1092-2 Rp 3 569802


TP, TPE 80
TPD 80
80 mm,
For welding 10 bar, EN 1092-2 569801
ø138 nominal
ø160
Threaded For welding ø200
TM03 0482 5204

Threaded 16 bar, EN 1092-2 Rp 3 569802

80 mm,
For welding 16 bar, EN 1092-2 569801
nominal

201
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Accessories

Pipe Product
Counterflange Pump type Description Rated pressure
connection number

Threaded 6 bar, EN 1092-2 Rp 4 579901

100 mm,
For welding 6 bar, EN 1092-2 579902
nominal
Rp 4 ø19

Threaded 10 bar, EN 1092-2 Rp 4 98999516


TP, TPE 100
TPD 100
100 mm,
For welding 10 bar, EN 1092-2 579802
ø158 nominal
ø180
Threaded For welding ø220

TM03 0483 5204


Threaded 16 bar, EN 1092-2 Rp 4 98999516

100 mm,
For welding 16 bar, EN 1092-2 579802
nominal

Threaded 10 bar, EN 1092-2 Rp 5 485367


Rp 5 ø19
125 mm,
For welding 10 bar, EN 1092-2 485368
nominal
TP, TPE 125
TPD 125
TM03 0484 5204

Threaded 16 bar, EN 1092-2 Rp 5 485367


ø188
ø210
Threaded For welding ø250
125 mm,
For welding 16 bar, EN 1092-2 485368
nominal

ø23
150 mm,
For welding 10 bar, EN 1092-2 S1111600
nominal
TP, TPE 150
TM03 0485 5204

TPD 150
ø212 150 mm,
For welding 16 bar, EN 1092-2 S1111600
ø240 nominal
For welding ø285

202
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Adapter flanges for various port-to-port lengths

Accessories
Diameter D Pitch circle diameter D1
Height (H) Product number
DN [mm] [mm] Adapter flange
[mm]
PN 6 PN 10/16 PN 6 PN 10/16 PN 6 PN 10/16

1 x 220 - - 90 100 D1
98848068 98849069

H
1 x 120 - - 90 100 98387529 98387530

32

1 x 60 70 78 - - 98387527 98387528
D

H
1 x 30 70 78 - - 98387531 98387588

1 x 70 - - 100 110 539921 539721

D1

40 1 x 90 - - 100 110 98387590 98387591

H
1 x 190 - - 100 110 98387592 98387593

1 x 160 - - 110 125 98387594 98387595


D1

H
50 1 x 60 - - 110 125 549924 549824

1 x 40 90 102 - - 96281077 96608516


H

D1

1 x 135 - - 130 145 98391271 98391272


H

65
D

1 x 20 110 122 - - 98391273 98391274


H

D1

80 1 x 80 - - 150 160 98391275 98391276


H

D1

100 1 x 100 - - 170 180 98391277 98391278


H

203
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Base plates TPE2 D, TPE3 D


Accessories

Note: TPE2, TPE3 pumps are not designed to be Pump type Hexagon head screws
Product
supplied with a base plate. Base plates are supplied as number

standard with TP, TPE pumps with 11 kW motors and TPE2 D, TPE3 D 32 99150053
above. TPE2 D, TPE3 D 40 99150054
TPE2 D, TPE3 D 50 3 x M12 x 40 mm 99150055
Some of the TP Series 300 pumps are provided with TPE2 D, TPE3 D 65
mounting feet and cannot be supplied with a base 99150056
TPE2 D, TPE3 D 80
plate. See fig. 96. TPE2 D, TPE3 D 100 3 x M12 x 16 mm 99150057

Drawing, TPE2 D, TPE3 D 32, 40, 50, 65

380 C
290 35

290
380

TM06 7445 3516


A B

A
7x 14
20
TM06 1083 1614

Drawing, TPE2 D, TPE3 D 80

380 151
290 35

Fig. 96 Principal sketch of a Series 300 pump designed


with mounting feet (A)

290
380

TM06 7481 3616


61 9

7x 14
20

Drawing, TPE2 D, TPE3 D 100

380
290 138

81 79 35
380

290

TM06 7482 3616

7x 14

Dimensions [mm]
Pump type Product number
A B C
TPE2 D, TPE3 D 32 0 69 123 99150053
TPE2 D, TPE3 D 40 5 45 124 99150054
TPE2 D, TPE3 D 50 8 18 130 99150055
TPE2 D, TPE3 D 65 50 0 132 99150056
TPE2 D, TPE3 D 80 99150056
TPE2 D, TPE3 D 100 99150057

204
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
TP Series 200 TP, TPE Series 300

Accessories
Hexagon head Product Product
Pump type Pump type Hexagon head screws
screws number number
TP 32 TP, TPE 80-230/4
TP 40 TP, TPE 80-280/4
2 x M12 x 20 mm 96591246
TP 50 TP, TPE 80-340/4
TP 65-80/2, 65-160/2, 65-240/2 TP, TPE 80-410/4
TP 65-40/4, 65-80/4 TP, TPE 80-460/4
TP 80 2 x M16 x 30 mm 96591245 TP, TPE 80-510/4
TP 100 TP, TPE 100-350/2
TP, TPE 100-380/2
TP, TPE 100-530/2
Drawing Product number TP, TPE 100-630/2
2 x M16 x 30 mm 96536246
235
TP, TPE 100-700/2
195 35
TP 100-760/2
2xø18
TP 100-940/2
TP 100-1040/2
TP 100-1200/2
TP 100-1360/2
TP 100-1510/2
2xø14
96591246
TP, TPE 100-xx/4
160
195
80

96591245
2xø14 TP, TPE 125-xx/4
TM00 9835 0497

TP, TPE 150-xx/4


TP, TPE 100-260/4
2xø18 2 x M16 x 30 mm 98522984
4xø14 TP 100-350/4
120
200
Drawing Product number

TP, TPE Series 300 380


290
35
Product 230
Pump type Hexagon head screws
number
TP, TPE 32
TP, TPE 40 4xø14 96536246
TP, TPE 50 98522984

TM02 8869 3516


290

TP, TPE 65
TP, TPE 80-xx/2
TP 80-110/4 2 x M16 x 30 mm 00485031 2xø18
TP, TPE 80-150/4
TP, TPE 80-170/4
TP, TPE 100-230/2
TP, TPE 100-300/2
TP, TPE 100-370/2 TPD Series 300

Product
Product Pump type Hexagon head screws
Drawing number
number
TPD 32
235 TPD 40
195 35 TPD 50
2xø14 TPD 65
TPD 80-xx/2
TPD 80-110/4 4 x M16 x 30 mm 96489381
TPD 80-150/4
00485031 TPD 80-170/4
195

TPD 100-230/2
96

2xø18
TM00 3755 2602

TPD 100-300/2
TPD 100-370/2

4xø14 Product
144 Drawing
number
35

175 2xø18
96489381
TM02 5336 2602
47
67

300
2xø14
330

205
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

TPD Series 300


Accessories

Pump type Hexagon head screws Product number


TPD 100-350/2
TPD 100-380/2
TPD 100-530/2
TPD 100-630/2
TPD 100-700/2 4 x M16 x 30 mm 96536247
TPD 100-100/4
TPD 100-130/4
TPD 100-150/4
TPD 100-170/4

Drawing Product number


35

2xø18
96536247
TM02 8870 1004

230
47
67

355
2xø14
385

TPD Series 300

Pump type Hexagon head screws Product number


TPD 80-230/4
TPD 80-280/4
TPD 80-340/4
TPD 80-410/4
TPD 80-460/4
TPD 80-510/4
TPD 100-200/4
TPD 100-240/4
4 x M16 x 30 mm 96536248
TPD 100-260/4
TPD 100-290/4
TPD 100-340/4
TPD 100-350/4
TPD 100-390/4
TPD 100-470/4
TPD 125-xx/4
TPD 150-xx/4

Drawing Product number


35

350
TM02 8871 1004

300 4xø18
96536248
47
67

475
2xø14
505

206
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Blanking flanges

Accessories
Normally used with twin-head pumps.

TM00 6360 3495


Fig. 97 Blanking flange

TPE2 D, TPE3 D

Pump type Product number


All TPE2 D, TPE3 D pumps 98159372

TPD 2-pole

Pump type 96495694 96495695 96495696 96525962 96525963 96525964


TPD 32-300/2 ●
TPD 32-360/2 ●
TPD 32-450/2 ●
TPD 32-550/2 ●
TPD 32-680/2 ●
TPD 32-820/2 ●
TPD 40-400/2 ●
TPD 40-460/2 ●
TPD 40-530/2 ●
TPD 40-690/2 ●
TPD 40-820/2 ●
TPD 40-920/2 ●
TPD 50-250/2 ●
TPD 50-300/2 ●
TPD 50-350/2 ●
TPD 50-410/2 ●
TPD 50-430/2 ●
TPD 50-530/2 ●
TPD 50-640/2 ●
TPD 50-720/2 ●
TPD 50-790/2 ●
TPD 50-880/2 ●
TPD 50-1050/2 ●
TPD 65-200/2 ●
TPD 65-250/2 ●
TPD 65-340/2 ●
TPD 65-390/2 ●
TPD 65-480/2 ●
TPD 65-540/2 ●
TPD 65-630/2 ●
TPD 65-740/2 ●
TPD 65-910/2 ●
TPD 65-920/2 ●
TPD 65-1050/2 ●
TPD 80-200/2 ●
TPD 80-240/2 ●
TPD 80-290/2 ●
TPD 80-330/2 ●
TPD 80-400/2 ●
TPD 80-480/2 ●
TPD 80-530/2 ●
TPD 80-640/2 ●
TPD 80-750/2 ●

207
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
Accessories

Pump type 96495694 96495695 96495696 96525962 96525963 96525964


TPD 100-230/2 ●
TPD 100-300/2 ●
TPD 100-370/2 ●
TPD 100-350/2 ●
TPD 100-380/2 ●
TPD 100-530/2 ●
TPD 100-630/2 ●
TPD 100-700/2 ●

TPD 4-pole

Pump type 96495694 96495695 96495696 96525962 96525963 96525964


TPD 32-120/4 ●
TPD 32-140/4 ●
TPD 32-190/4 ●
TPD 40-110/4 ●
TPD 40-150/4 ●
TPD 40-180/4 ●
TPD 40-230/4 ●
TPD 50-100/4 ●
TPD 50-115/4 ●
TPD 50-130/4 ●
TPD 50-180/4 ●
TPD 50-240/4 ●
TPD 50-270/4 ●
TPD 50-340/4 ●
TPD 65-130/4 ●
TPD 65-150/4 ●
TPD 65-190/4 ●
TPD 65-230/4 ●
TPD 65-310/4 ●
TPD 65-330/4 ●
TPD 80-110/4 ●
TPD 80-150/4 ●
TPD 80-170/4 ●
TPD 80-230/4 ●
TPD 80-280/4 ●
TPD 80-340/4 ●
TPD 80-410/4 ●
TPD 80-460/4 ●
TPD 80-510/4 ●
TPD 100-100/4 ●
TPD 100-150/4 ●
TPD 100-130/4 ●
TPD 100-170/4 ●
TPD 100-260/4 ●
TPD 100-200/4 ●
TPD 100-240/4 ●
TPD 100-290/4 ●
TPD 100-340/4 ●
TPD 100-350/4 ●
TPD 100-390/4 ●
TPD 100-470/4 ●
TPD 125-200/4 ●
TPD 125-230/4 ●
TPD 125-280/4 ●
TPD 125-340/4 ●
TPD 125-365/4 ●
TPD 125-420/4 ●
TPD 125-480/4 ●
TPD 150-180/4 ●
TPD 150-210/4 ●
TPD 150-240/4 ●
TPD 150-300/4 ●
TPD 150-340/4 ●

208
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Insulating kits

Accessories
Insulating kits are available for TPE2 and TPE3
pumps.
The insulating kit consists of two shells.
The insulating kit is tailored to the individual pump
model and encloses the entire pump housing, thus
providing optimum insulation.

TM00 8095 2496


Fig. 98 Insulating kit

Kits for TPE2, TPE3 pumps


Pump type Product number
TPE2, TPE3 32-80/120/150/180/200 98159366
TPE2, TPE3 40-80/120/150/180/200/240 98159368
TPE2, TPE3 50-60/80/120/150/180/200/240 98159367
TPE2, TPE3 65-60/80/120/150/180/200 98159361
TPE2, TPE3 80-40/120/150/180 98159363
TPE2, TPE3 100-40/120/150/180 98159362

209
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Sensors
Accessories

Flow sensors

O-ring Connection type


Grundfos Vortex flow Flow range Pipe
Type Product number
sensor, VFI 1) [m3/h] connection EPDM FKM Cast-iron Stainless-steel
flange flange
VFI 1.3-25 DN32 020 E ● ● 97686141
VFI 1.3-25 DN32 020 F ● ● 97686142
1.3 - 25 DN 32
VFI 1.3-25 DN32 020 E ● ● 97688297
VFI 1.3-25 DN32 020 F ● ● 97688298
VFI 2-40 DN40 020 E ● ● 97686143
VFI 2-40 DN40 020 F ● ● 97686144
2-40 DN 40
VFI 2-40 DN40 020 E ● ● 97688299
VFI 2-40 DN40 020 F ● ● 97688300
VFI 3.2-64 DN50 020 E ● ● 97686145
VFI 3.2-64 DN50 020 F ● ● 97686146
2-64 DN 50
VFI 3.2-64 DN50 020 E ● ● 97688301
• Sensor tube with sensor VFI 3.2-64 DN50 020 F ● ● 97688302
sensor tube of 1.4408 VFI 5.2-104 DN65 020 E ● ● 97686147
and sensor of 1.4404 VFI 5.2-104 DN65 020 F ● ● 97686148
• 4-20 mA output signal 5.2 - 104 DN 65
VFI 5.2-104 DN65 020 E ● ● 97688303
• 2 flanges
• 5 m cable with M12 VFI 5.2-104 DN65 020 F ● ● 97688304
connection in one end VFI 8-160 DN80 020 E ● ● 97686149
• quick guide. VFI 8-160 DN80 020 F ● ● 97686150
8-160 DN 80
VFI 8-160 DN80 020 E ● ● 97688305
VFI 8-160 DN80 020 F ● ● 97688306
VFI 12-240 DN100 020 E ● ● 97686151
VFI 12-240 DN100 020 F ● ● 97686152
12-240 DN 100
VFI 12-240 DN100 020 E ● ● 97688308
VFI 12-240 DN100 020 F ● ● 97688309
1) For more information about the VFI sensor, see the data booklet "Grundfos direct sensors", publication number 97790189.

210
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Temperature sensors

Accessories
Temperature sensor, TTA
Temperature sensor with Pt100 temperature sensor
fitted in a ∅6 x 100 mm measuring tube made of
stainless steel, DIN 1.4571 and a 4-20 mA sensor built
into a type B head DIN 43.729.
The connecting head is made of painted pressure
die-cast aluminium with Pg 16 screwed connection,
stainless screws and neoprene rubber gasket.
The sensor is built into the system either by means of
a cutting ring bush or by means of one of the two
matching protecting tubes ∅9 x 100 mm or ∅9 x 50
mm, respectively.
The protecting tube has G 1/2 connection.
Cutting ring bush or protecting tube must be ordered
separately.
Technical data

Type TTA (-25) 25 TTA (0) 25 TTA (0) 150 TTA (50) 100
Product number 96430194 96432591 96430195 96432592
Measuring range -25 to +25 °C 0 to +25 °C 0 to +150 °C 50 to +100 °C
Measuring accuracy According to IEC 751, class B, 0.3 °C at 0 °C
Response time, τ (0.9) in water Without protecting tube: 28 seconds
0.2 m/s With oil-filled protecting tube: 75 seconds
Enclosure class IP55
Output signal 4-20 mA
Supply voltage 8-35 VDC
EMC, electromagnetic Emission: According to EN 50081
compatibility Immunity: According to EN 50082

Accessories

Protecting tube Protecting tube


Type Cutting ring bush
∅9 x 50 mm ∅9 x 100 mm
Product number 96430201 96430202 96430203
Protecting tube of stainless steel SINOX SSH 2 for ∅6 mm measuring tube. Cutting ring bush for ∅6 mm measuring tube.
Description
Pipe connection G 1/2. Pipe connection G 1/2.

Protecting tube

Type L

∅9 x 50 49

∅9 x 100 99

Cutting ring bush

Fig. 99 Dimensional sketch

211
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

Differential-temperature sensor, HONSBERG


Accessories

Iout [mA]
ETSD1-04-020
The temperature sensors T1 and T2 measure the
20 ETSD1-04-050
temperature in their respective location at the same
time. Besides the temperature measurement, the T1 15
features an electronic unit calculating the temperature
difference between T1 and T2 and transmitting the 10
result as a 4-20 mA signal via a current amplifier.

TM02 1339 1001


As the measured signal transmitted from the T2 is also T1-T2
4 Diff. temp.
a current signal, a relatively large distance is allowed
between T2 and T1. -50 -40 -30 -20 -10 0 10 20 30 40 50 [°C]
As appears from fig. 100, it has no effect on the output
signal, Iout, which of the sensors that measures the Fig. 100 Sensor characteristics
highest temperature.
Thus, the current signal generated will always be
positive between 4 and 20 mA.
Technical data

ETSD1-04-020K045 ETSD1-04-050K045
Type ETSD1- 04- 020 K 045 Specification
+ ETSD2-K045 + ETSD2-K045
Product number 96409362 96409363 ETSD1- Reference temperature, T1.
Measuring range:
Temperature difference 0 to +20 °C 0 to +50 °C 04- 0 °C corresponds to 4 mA.
(T1-T2) or (T2-T1)
Supply voltage 15-30 VDC 020 20 °C corresponds to 20 mA.
Output signal 4-20 mA 050 50 °C corresponds to 20 mA.
Material in contact with liquid:
Measuring accuracy ± 0.3 % FS K
Stainless steel, DIN 1.4571.
Repeatability ± 1 % FS 045 Length of sensing element: 45 mm.
Response time, τ (0.9) 2 minutes
Ambient temperature -25 to +85 °C ETSD2- K 045 Specification
Operating temperature of
-25 to +105 °C ETSD2- Reference temperature, T2.
T1 and T2
Maximum distance Material in contact with liquid: Stainless steel,
300 m with screened cable K
between T1 and T2 DIN 1.4571.
Between T1 and T2: M12 x 1 plug (including
Electrical connection in kit), output signal with DIN 43650-A plug 045 Length of sensing element: 45 mm.
type
Storage temperature -45 to +125 °C
Short-circuit-proof Yes
Protected against polarity
Yes, up to 40 V
reversal
Materials in contact with
Stainless steel, DIN 1.4571
liquid
Enclosure class IP65
EMC, electromagnetic Emission: According to EN 50081
compatibility Immunity: According to EN 50082

212
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Installing the sensor

Accessories
Fit the two sensors in such a way that the sensing
elements are located in the middle of the flow of the
liquid to be measured.

140

54
SW
For tightening, use only the hexagon nut. 27
G 1/2

You can turn the upper part of the sensors to any


position suitable for the connection of cables.

TM02 0705 5000


The sensors have G 1/2 thread. See fig. 101. SW
27
SW
27

93
G 1/2

18
45
27

Fig. 101 Dimensional sketch

Ambient temperature sensor

Sensor type Type Supplier Measuring range Product number


tmg
Temperature sensor, ambient temperature WR 52 -50 to +50 °C ID8295
DK: Plesner

Pressure sensors
Sensors for boosting applications

Danfoss pressure sensor kit Pressure range Product number


0 - 2.5 bar 96478188
0-4 bar 91072075
• Connection: G 1/2 A, DIN 16288 - B6kt
0-6 bar 91072076
• Electrical connection: plug DIN 43650
0-10 bar 91072077
0-16 bar 91072078
0 - 2.5 bar 405159
• Pressure sensor, type MBS 3000, with 2 m screened cable 0-4 bar 405160
Connection: G 1/4 A, DIN 16288 - B6kt
0-6 bar 405161
• 5 cable clips, black
• Fitting instructions PT, 00400212 0-10 bar 405162
0-16 bar 405163

Sensors for circulation applications

Grundfos differential pressure sensor, DPI Pressure range Product number


• 1 sensor including 0.9 m screened cable, 7/16" connections 0 - 0.6 bar 96611522
• 1 original DPI bracket for wall mounting
• 1 Grundfos bracket for mounting on motor 0 - 1.0 bar 96611523
• 2 M4 screws for mounting of sensor on bracket
• 1 M6 screw, self-cutting, for mounting on MGE 90/100 0 - 1.6 bar 96611524
• 1 M8 screw, self-cutting, for mounting on MGE 112/132
• 1 M10 screw, self-cutting, for mounting on MGE 160 0 - 2.5 bar 96611525
• 1 M12 screw, self-cutting, for mounting on MGE 180
• 3 capillary tubes, short/long 0 - 4.0 bar 96611526
• 2 fittings, 1/4" - 7/16"
• 5 cable clips, black 0 - 6.0 bar 96611527
• Installation and operating instructions
• Service kit instruction 0-10 bar 96611550

Select the differential pressure sensor so that the maximum pressure of the sensor is higher than the maximum differential pressure of the pump.

Sensor interface

Sensor interface, SI 001 PSU 1) Description Product number

Grundfos Direct Sensors™, type SI 001 PSU, is an external power supply for the VFI, DPI
and other transmitters with 24 VDC supply voltage.
96915820
The power supply is used when the cable between transmitter and controller is more than
30 m long.

1)
For further information about the PSU sensor interface, see the installation and operating instructions "SI 001 PSU - sensor interface", publication
number 96944355, or quick guide, publication number 96944356.

213
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

MP 204, advanced motor protection


Accessories

MP 204 is an electronic motor protection for pumps. One unit covers all electrical motors from 3 to 999 A as well as
voltages from 100 to 480 VAC.
Installation of MP 204 is by means of screws onto a wall or back plate, or on a mounting rail.
Component Description Functions

Features
• Phase-sequence monitoring
• indication of current or temperature
• input for PTC sensor or thermal switch
• indication of temperature in °C or °F
• 4-digit, 7-segment display
• setting and status reading with Grundfos R100 remote
control
• setting and status reading via Grundfos GENIbus fieldbus.
MP 204 is an electronic motor protector and data Tripping conditions
collecting unit. Apart from protecting the motor, it • Overload
MP 204
can also send information to a CIU unit via • underload, dry running
GENIbus, like for instance: • temperature
• trip • missing phase
• warning • phase sequence
• energy consumption • overvoltage
• input power • undervoltage
• motor temperature. • power factor, cos φ
MP 204 protects the motor primarily by • current unbalance.
measuring the motor current by means of a true Warnings
RMS measurement. • Overload
The pump is protected secondarily by measuring • underload
the temperature with a Tempcon sensor, a • temperature
Pt100/Pt1000 sensor and a PTC sensor/thermal • overvoltage
switch. • undervoltage
MP 204 is designed for single- and three-phase • power factor, cos φ
motors. • run capacitor, single-phase operation
• starting capacitor, single-phase operation
• loss of communication in network
• harmonic distortion.
Learning function
TM03 0150 4204

• Phase sequence, three-phase operation


• run capacitor, single-phase operation
• starting capacitor, single-phase operation
• identification and measurement of Pt100/Pt1000 sensor
circuit.

Control MP 204
Control MP 204 is supplied as a plug-and-play control cabinet solution.
You can see the main switch and LED panel showing the power consumption on the front. Inside you find the MP 204
unit and optional communication interface units.

Cabinet type Description Functions

Digital input
Control MP 204 • Float switch or pressure relay, if no IO 112 is used.
Analog input
• Too high motor temperature, Tempcon
• thermistor/PTC, pump
The Control MP 204 control cabinets are • pressure sensor, 4-20 mA, with IO 112.
supplied with all necessary components. Three Relay output
types of control cabinets are available, • Pump alarm.
depending on functions and starting method. Communication
Control MP 204 is designed for installation in a • Grundfos Remote Management.
control cabinet for outdoor use. • GSM/GPRS
The control cabinets have a built-in main switch IO 112 is not supported.
and a thermal magnetic circuit breaker. • Modbus RTU wired
TM04 9512 4410

IO 112 is not supported.


• PROFIBUS DP
IO 112 not supported.
Protection
• Protects the pump against short-circuit.

For more information about MP 204 and Control MP 204, see the data booklet "Control MP 204", publication number 97770915.

214
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
Potentiometer MI 301

Accessories
MI 301 is a module with built-in infrared and radio
communication. Use MI 301 in conjunction with
Android or iOS-based smart devices with a Bluetooth
connection. MI 301 has rechargeable Li-ion battery

TM02 1630 5102


and you must charge it separately.

Fig. 102 Potentiometer

TM05 3890 1712


Potentiometer for setpoint setting and start/stop of the
pump.
Product Product number
Fig. 104 MI 301
External potentiometer with cabinet for wall
625468
mounting.
Supplied with the product:
• Grundfos MI 301
Grundfos GO • sleeve
Grundfos GO is used for wireless infrared or radio • battery charger
communication with the pumps. • quick guide.
Various Grundfos GO variants are available. The
Product numbers
variants are described in the following.
MI 204 Grundfos GO variant Product number
Grundfos MI 204 98424092
MI 204 is an add-on module with built-in infrared and
Grundfos MI 204 including iPod touch 98612711
radio communication. You can use MI 204 in Grundfos MI 301 98046408
conjunction with an Apple iPhone or iPod with
Lightning connector.
MI 204 is also available together with an Apple iPod
touch and a cover.

MI 204
TM05 7704 1513

Fig. 103 MI 204

Supplied with the product:


• Grundfos MI 204
• sleeve
• quick guide
• charger cable.

215
27 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

CIU communication interface units CIM communication interface


Accessories

modules

GrA 6118

GrA 6121
Fig. 105 Grundfos CIU communication interface unit Fig. 106 Grundfos CIM communication interface module

The CIU units enable communication of operating The CIM modules enable communication of operating
data, such as measured values and setpoints, between data, such as measured values and setpoints, between
TPE pumps and a building management system. The TPE pumps and a building management system. The
CIU unit incorporates a 24-240 VAC/VDC power CIM modules are add-on communication modules
supply module and a CIM module. You can mount the which are fitted in the terminal box of TPE pumps.
CIM module on a DIN rail or on a wall. For further information see section
For further information see section 14. Communication.
14. Communication. Note: CIM modules must be fitted by authorised
We offer the following CIU units: personnel.
Description Fieldbus protocol Product number
We offer the following CIM modules:
CIU 100 LON 96753735 Description Fieldbus protocol Product number
CIU 150 PROFIBUS DP 96753081
CIM 050 GENIbus 96824631
CIU 200 Modbus RTU 96753082
CIM 100 LON 96824797
CIU 250* GSM/GPRS 96787106
CIM 150 PROFIBUS DP 96824793
CIU 270* GRM 96898819
CIM 200 Modbus RTU 96824796
CIU 300 BACnet MS/TP 96893769
CIM 250* GSM/GPRS 96824795
CIU 500 Modbus TCP 96753894
CIU 270* GRM 96898815
CIU 500 PROFINET IO 96753894
CIM 300 BACnet MS/TP 96893770
* Antenna not included. See below. CIM 500 Modbus TCP 98301408
CIM 500 PROFINET 98301408
Antennas for CIU 250 and 270
* Antenna not included. See below.
Description Product number
Antennas for CIM 250 and 270
Antenna for roof 97631956
Antenna for desk 97631957 Description Product number

For further information about data communication via Antenna for roof 97631956
Antenna for desk 97631957
CIU units and fieldbus protocols, see the CIU
documentation available in Grundfos Product Center. For further information about data communication via
See page 224. CIM modules and fieldbus protocols, see the CIM
documentation available in Grundfos Product Center.
See page 224.

216
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
27
EMC filter

Accessories
EMC, electromagnetic compatibility to EN 61800-3

Motor [kW]
Emission/immunity
2-pole 4-pole

0.37 0.37

0.55 0.55

0.75 0.75 Emission:


Motors may be installed in residential areas
1.1 1.1 (first environment), unrestricted distribution,
corresponding to CISPR11, group 1, class B.
1.5 1.5

2.2 2.2 Immunity:


Motors fulfil the requirements for both the first
3.0 3.0 and second environment.

4.0 4.0

5.5 -

- 5.5 Emission:
The motors are category C3, corresponding to
7.5 7.5 CISPR11, group 2, class A, and may be
installed in industrial areas (second
11 11
environment).
15 15 If equipped with an external Grundfos EMC
filter, the motors are category C2,
18.5 18.5 corresponding to CISPR11, group 1, class A,
and may be installed in residential areas (first
22 - environment).
TM02 9198 1203

Fig. 107 EMC filter

The EMC filter for residential areas is available as a


complete kit ready for installation.
Product Product number
EMC filter, TPE 5.5 kW, 4-pole and 7.5 kW 96041047
EMC filter, TPE 11-22 kW 96478309

217
28 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

28. Minimum inlet pressure - NPSH


Minimum inlet pressure - NPSH

To ensure optimum and noiseless operation we


recommend that you use the minimum inlet pressure
values shown on pages 220 to 221.
A minimum inlet pressure is required to avoid pressure
drops that may cause cavitation.
Use the following formula to calculate the minimum
inlet pressure, ps in bar relative. The pressure gauge
value on the pump inlet side.
Note: Base the calculation of the minimum inlet
pressure on the maximum required flow.

1
p   NPSH R    g – ---    c 2  0,00001 – p + p [bar relative]
s  2  b d

ps = Minimum inlet pressure in bar. Temp. Pd


NPSHR = The required Net Positive Suction Head in [˚C] [bar]
m head, to be read from the NPSH curve 150 4.76
at the highest flow the pump will be Ps
c 140 3.61
delivering.
130 2.70
ρ = Density of the pumped liquid measured in
kg/m3. 120 1.99
g = Gravitational acceleration measured in 110 1.43
m/s. For estimated calculations, use the NPSH
100 1.01
value 9.81 m/s2.
90 0.70
c = Flow velocity of the pumped liquid at the
pressure gauge. Insert the flow velocity 80 0.47
as the unit [m/s]. 70 0.31

TM02 8491 0204 - TM03 0371 5004


See individual curve charts from page 60 0.20
124.
50 0.12
pb = Barometric pressure in bar.
40 0.07
Set the barometric pressure to 0.97 bar.
30 0.04
Note: Only occasionally is the pressure
as high as 1 bar. Furthermore, this value 20 0.02
is at sea level. 10 0.01
pd = Vapour pressure in bar. See fig. 108.
0

Fig. 108 Minimum inlet pressure

218
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
28
TPE2, TPE2 D, TPE3, TPE3 D

Minimum inlet pressure - NPSH


p [bar]
Pump type
20 °C 60 °C 90 °C 110 °C 120 °C
TPE2, TPE2 D, TPE3, TPE3 D 32-80 0.1 0.1 0.2 0.9 1.5
TPE2, TPE2 D, TPE3, TPE3 D 32-120 0.1 0.1 0.2 0.9 1.5
TPE2, TPE2 D, TPE3, TPE3 D 32-150 0.1 0.1 0.4 1.1 1.7
TPE2, TPE2 D, TPE3, TPE3 D 32-180 0.1 0.2 0.6 1.3 1.9
TPE2, TPE2 D, TPE3, TPE3 D 32-200 0.2 0.4 0.9 1.6 2.2
TPE2, TPE2 D, TPE3, TPE3 D 40-80 0.1 0.1 0.2 0.9 1.5
TPE2, TPE2 D, TPE3, TPE3 D 40-120 0.1 0.1 0.2 0.9 1.5
TPE2, TPE2 D, TPE3, TPE3 D 40-150 0.1 0.1 0.5 1.2 1.8
TPE2, TPE2 D, TPE3, TPE3 D 40-180 0.1 0.1 0.6 1.3 1.9
TPE2, TPE2 D, TPE3, TPE3 D 40-200 0.1 0.2 0.7 1.4 2.0
TPE2, TPE2 D, TPE3, TPE3 D 40-240 0.1 0.3 0.8 1.5 2.1
TPE2, TPE2 D, TPE3, TPE3 D 50-60 0.1 0.1 0.5 1.2 1.8
TPE2, TPE2 D, TPE3, TPE3 D 50-80 0.1 0.3 0.8 1.5 2.1
TPE2, TPE2 D, TPE3, TPE3 D 50-120 0.4 0.6 1.1 1.8 2.4
TPE2, TPE2 D, TPE3, TPE3 D 50-150 0.6 0.8 1.3 2.0 2.6
TPE2, TPE2 D, TPE3, TPE3 D 50-180 0.7 0.9 1.4 2.1 2.7
TPE2, TPE2 D, TPE3, TPE3 D 50-200 0.9 1.1 1.6 2.3 2.9
TPE2, TPE2 D, TPE3, TPE3 D 50-240 0.9 1.1 1.6 2.3 2.9
TPE2, TPE2 D, TPE3, TPE3 D 65-60 0.1 0.1 0.2 0.9 1.5
TPE2, TPE2 D, TPE3, TPE3 D 65-80 0.1 0.1 0.3 1.1 1.7
TPE2, TPE2 D, TPE3, TPE3 D 65-120 0.1 0.2 0.6 1.4 2.0
TPE2, TPE2 D, TPE3, TPE3 D 65-150 0.1 0.2 0.7 1.5 2.1
TPE2, TPE2 D, TPE3, TPE3 D 65-180 0.3 0.5 1.0 1.8 2.4
TPE2, TPE2 D, TPE3, TPE3 D 65-200 0.6 0.8 1.3 2.1 2.7
TPE2, TPE2 D, TPE3, TPE3 D 80-40 0.1 0.1 0.3 1 1.6
TPE2, TPE2 D, TPE3, TPE3 D 80-120 0.1 0.3 0.9 1.5 2.1
TPE2, TPE2 D, TPE3, TPE3 D 80-150 0.1 0.3 0.9 1.5 2.1
TPE2, TPE2 D, TPE3, TPE3 D 80-180 0.3 0.5 1.1 1.7 2.3
TPE2, TPE2 D, TPE3, TPE3 D 100-40 0.1 0.1 0.4 1.1 1.7
TPE2, TPE2 D, TPE3, TPE3 D 100-120 0.1 0.1 0.6 1.3 1.9
TPE2, TPE2 D, TPE3, TPE3 D 100-150 0.1 0.2 0.7 1.4 2.0
TPE2, TPE2 D, TPE3, TPE3 D 100-180 0.1 0.3 0.8 1.5 2.1

219
28 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

TP, TPE, TPD 2-pole, PN 6, 10, 16, 25


Minimum inlet pressure - NPSH

p [bar] p [bar]
Pump type Pump type
20 °C 60 °C 90 °C 110 °C 120 °C 140 °C 150 °C 20 °C 60 °C 90 °C 110 °C 120 °C 140 °C 150 °C

TP 32-80/2 0.4 0.4 0.4 1.2 1.7 3.4 - TP 80-160/2 2.1 2.3 2.8 3.6 4.1 5.8 -
TP 32-160/2 0.4 0.6 1.1 1.9 2.4 4.1 - TP, TPD 80-200/2 0.5 0.7 1.2 1.9 2.5 4.1 -
TP 32-220/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 80-240/2 0.1 0.2 0.7 1.4 2.0 3.6 -
TP 32-260/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 80-290/2 0.1 0.3 0.8 1.5 2.1 3.7 -
TP 32-330/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 80-330/2 0.2 0.4 0.9 1.7 2.2 3.8 -
TP, TPD 32-300/2 0.1 0.1 0.1 0.7 1.2 2.8 - TP, TPD 80-400/2 0.6 0.8 1.3 2.1 2.6 4.2 -
TP, TPD 32-360/2 0.1 0.1 0.1 0.7 1.2 2.8 - TP, TPD 80-480/2 0.1 0.3 0.8 1.5 2.1 3.7 -
TP, TPD 32-450/2 0.1 0.1 0.1 0.7 1.2 2.8 - TP, TPD 80-530/2 0.2 0.4 0.9 1.6 2.1 3.8 -
TP, TPD 32-550/2 0.1 0.1 0.1 0.7 1.2 2.9 - TP, TPD 80-640/2 0.6 0.8 1.3 2.0 2.6 4.2 -
TP, TPD 32-680/2 0.1 0.1 0.2 0.9 1.5 3.1 - TP, TPD 80-750/2 0.6 0.8 1.3 2.0 2.6 4.2 -
TP, TPD 32-820/2 0.5 0.7 1.2 1.9 2.5 4.1 - TP, TPD 100-230/2 0.4 0.6 1.1 1.9 2.4 4.0 -
TP 40-80/2 0.1 0.3 0.8 1.6 2.1 3.8 - TP, TPD 100-300/2 0.2 0.4 0.9 1.6 2.2 3.8 -
TP 40-160/2 0.1 0.2 0.7 1.5 2.0 3.7 - TP, TPD 100-370/2 0.3 0.5 1.0 1.7 2.3 3.9 -
TP 40-240/2 0.4 0.6 1.1 1.9 2.4 4.1 - TP, TPD 100-350/2 0.9 1.1 1.6 2.3 2.9 4.5 -
TP 40-270/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 100-380/2 1.2 1.4 1.9 2.6 3.2 4.8 -
TP 40-330/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 100-530/2 1.7 1.9 2.4 3.2 3.7 5.3 -
TP 40-390/2 0.7 0.9 1.4 2.2 2.7 4.4 - TP, TPD 100-630/2 1.4 1.6 2.1 2.8 3.3 5.0 -
TP, TPD 40-400/2 0.1 0.1 0.1 0.9 1.4 3.1 - TP, TPD 100-700/2 3.0 3.2 3.7 4.4 5.0 6.6 -
TP, TPD 40-460/2 0.1 0.1 0.3 1.0 1.6 3.2 - TP 100-760/2 1.7 1.9 2.3 3.3 3.8 5.4 6.7
TP, TPD 40-530/2 0.1 0.1 0.4 1.1 1.7 3.3 - TP 100-940/2 1.6 1.8 2.2 3.2 3.7 5.3 6.6
TP, TPD 40-690/2 0.1 0.2 0.7 1.4 2.0 3.6 - TP 100-1040/2 1.6 1.8 2.2 3.2 3.7 5.3 6.6
TP, TPD 40-820/2 0.1 0.3 0.8 1.6 2.1 3.7 - TP 100-1200/2 1.9 2.1 2.5 3.5 4.0 5.6 6.9
TP, TPD 40-920/2 0.4 0.6 1.1 1.8 2.4 4.0 - TP 100-1360/2 1.8 2.0 2.4 3.4 3.9 5.5 6.8
TP 50-80/2 0.1 0.1 0.6 1.4 1.9 3.6 - TP 100-1510/2 1.8 2.0 2.4 3.4 3.9 5.5 6.8
TP 50-160/2 0.4 0.6 1.1 1.9 2.4 4.1 -
TP 50-240/2 0.3 0.5 1.0 1.8 2.3 4.0 -
TP, TPD 50-250/2 0.1 0.1 0.2 1.0 1.5 3.1 -
TP, TPD 50-300/2 0.1 0.1 0.3 1.0 1.6 3.2 -
TP, TPD 50-350/2 0.1 0.1 0.3 1.0 1.6 3.2 -
TP, TPD 50-410/2 0.1 0.1 0.4 1.1 1.6 3.3 -
TP, TPD 50-430/2 0.1 0.1 0.4 1.1 1.7 3.3 -
TP, TPD 50-530/2 0.1 0.1 0.5 1.3 1.8 3.5 -
TP, TPD 50-640/2 0.1 0.1 0.6 1.4 1.9 3.5 -
TP, TPD 50-720/2 0.1 0.3 0.8 1.6 2.1 3.7 -
TP, TPD 50-790/2 0.5 0.7 1.2 1.9 2.5 4.1 -
TP, TPD 50-880/2 0.8 1.0 1.5 2.2 2.8 4.4 -
TP 50-1050/2 1.1 1.3 1.8 2.5 3.1 4.7 -
TP 65-80/2 0.6 0.8 1.3 2.1 2.6 4.3 -
TP 65-160/2 1.1 1.3 1.8 2.6 3.1 4.8 -
TP 65-240/2 0.9 1.1 1.6 2.4 2.9 4.6 -
TP, TPD 65-200/2 0.1 0.1 0.3 1.0 1.5 3.2 -
TP, TPD 65-250/2 0.1 0.1 0.4 1.1 1.7 3.3 -
TP, TPD 65-340/2 0.1 0.1 0.2 1.0 1.5 3.1 -
TP, TPD 65-390/2 0.1 0.1 0.3 1.0 1.5 3.2 -
TP, TPD 65-480/2 0.1 0.1 0.3 1.0 1.6 3.2 -
TP, TPD 65-540/2 0.1 0.1 0.3 1.1 1.6 3.2 -
TP, TPD 65-630/2 0.1 0.1 0.4 1.1 1.7 3.3 -
TP, TPD 65-740/2 0.1 0.1 0.6 1.3 1.9 3.5 -
TP, TPD 65-910/2 0.1 0.2 0.7 1.5 2.0 3.6 -
TP, TPD 65-920/2 0.1 0.2 0.7 1.4 2.0 3.6 -
TP, TPD 65-1050/2 0.1 0.2 0.7 1.5 2.0 3.6 -

220
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
28
TP, TPE, TPD 4-pole, PN 6, 10, 16, 25

Minimum inlet pressure - NPSH


p [bar] p [bar]
Pump type Pump type
20 °C 60 °C 90 °C 110 °C 120 °C 140 °C 150 °C 20 °C 60 °C 90 °C 110 °C 120 °C 140 °C 150 °C

TP 32-40/4 0.1 0.1 0.1 0.9 1.4 3.1 - TP, TPD 125-480/4 0.1 0.1 0.5 1.2 1.8 3.4 4.7
TP 32-80/4 0.1 0.1 0.5 1.3 1.8 3.5 - TP 125-550/4 0.1 0.3 0.7 1.7 2.2 3.8 5.1
TP, TPD 32-120/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 125-580/4 0.1 0.3 0.7 1.7 2.2 3.8 5.1
TP, TPD 32-140/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 150-130/4 0.1 0.1 0.5 1.2 1.8 3.4 -
TP, TPD 32-190/4 0.1 0.1 0.1 0.8 1.4 3.0 - TP 150-160/4 0.1 0.2 0.7 1.5 2.0 3.6 -
TP 40-40/4 0.1 0.1 0.3 1.1 1.6 3.3 - TP 150-200/4 0.2 0.4 0.9 1.6 2.1 3.8 -
TP 40-80/4 0.1 0.1 0.2 1.0 1.5 3.2 - TP 150-220/4 0.3 0.5 1.0 1.7 2.3 3.9 -
TP, TPD 40-110/4 0.1 0.1 0.1 0.6 1.2 2.8 - TP, TPD 150-180/4 0.1 0.2 0.7 1.4 1.9 3.6 4.9
TP, TPD 40-150/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP, TPD 150-210/4 0.1 0.2 0.7 1.4 2.0 3.6 4.9
TP, TPD 40-180/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP, TPD 150-240/4 0.1 0.2 0.7 1.5 2.0 3.6 4.9
TP, TPD 40-230/4 0.1 0.1 0.1 0.8 1.3 3.0 - TP, TPD 150-300/4 0.1 0.3 0.8 1.5 2.1 3.7 5.0
TP 50-40/4 0.1 0.1 0.3 1.1 1.6 3.3 - TP, TPD 150-340/4 0.1 0.3 0.8 1.5 2.1 3.7 5.0
TP 50-80/4 0.1 0.1 0.3 1.1 1.6 3.3 - TP 150-360/4 0.3 0.5 1.0 1.8 2.3 4.0 5.3
TP, TPD 50-100/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 150-400/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 50-115/4 0.1 0.1 0.1 0.8 1.4 3.0 - TP 150-440/4 0.1 0.1 0.4 1.1 1.7 3.3 4.6
TP, TPD 50-130/4 0.1 0.1 0.1 0.9 1.4 3.0 - TP 150-480/4 0.1 0.1 0.5 1.3 1.8 3.4 4.7
TP, TPD 50-180/4 0.1 0.1 0.1 0.8 1.3 3.0 - TP 150-610/4 0.1 0.2 0.7 1.4 2.0 3.6 4.9
TP, TPD 50-240/4 0.1 0.1 0.2 0.9 1.5 3.1 - TP 150-700/4 0.1 0.3 0.8 1.5 2.1 3.7 5.0
TP, TPD 50-270/4 0.1 0.1 0.3 1.0 1.6 3.2 - TP 150-810/4 0.3 0.4 0.9 1.7 2.2 3.8 5.1
TP, TPD 50-340/4 0.1 0.2 0.7 1.4 2.0 3.6 - TP 150-960/4 0.4 0.6 1.1 1.8 2.3 3.8 5.1
TP 65-40/4 0.4 0.6 1.1 1.9 2.4 4.1 - TP 200-80/4 0.9 1.1 1.6 2.3 2.9 4.5 -
TP 65-80/4 0.7 0.9 1.4 2.2 2.7 4.4 - TP 200-110/4 0.5 0.6 1.1 1.9 2.4 4.0 -
TP, TPD 65-130/4 0.1 0.1 0.1 0.6 1.2 2.8 - TP 200-140/4 0.3 0.5 1.0 1.7 2.3 3.9 -
TP, TPD 65-150/4 0.1 0.1 0.1 0.6 1.2 2.8 - TP 200-190/4 0.2 0.4 0.9 1.6 2.2 3.8 -
TP, TPD 65-190/4 0.1 0.1 0.1 0.6 1.2 2.8 - TP 200-210/4 0.1 0.2 0.7 1.4 2.0 3.6 -
TP, TPD 65-230/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 200-250/4 0.9 1.0 1.5 2.3 2.8 4.4 5.7
TP, TPD 65-310/4 0.1 0.1 0.1 0.7 1.3 2.9 - TP 200-280/4 0.7 0.9 1.4 2.1 2.7 4.3 5.6
TP, TPD 65-330/4 0.1 0.1 0.1 0.3 0.8 2.5 - TP 200-320/4 0.6 0.8 1.3 2.0 2.6 4.2 5.5
TP 80-40/4 1.5 1.7 2.2 3.0 3.5 5.2 - TP 200-360/4 0.4 0.6 1.1 1.8 2.4 4.0 5.3
TP 80-80/4 1.6 1.8 2.3 3.1 3.6 5.3 - TP 200-390/4 0.3 0.5 1.0 1.7 2.2 3.9 5.2
TP, TPD 80-110/4 0.1 0.1 0.1 0.8 1.4 3.0 - TP 200-400/4 0.1 0.1 0.6 1.3 1.9 3.6 4.9
TP, TPD 80-150/4 0.1 0.1 0.1 0.8 1.3 2.9 - TP 200-430/4 0.1 0.1 0.6 1.4 1.9 3.6 4.9
TP, TPD 80-170/4 0.1 0.1 0.1 0.8 1.3 3.0 - TP 200-440/4 0.1 0.2 0.7 1.5 2.0 3.7 5.0
TP, TPD 80-230/4 0.1 0.1 0.3 1.0 1.6 3.2 - TP 200-490/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 80-280/4 0.1 0.1 0.2 1.0 1.5 3.1 - TP 200-500/4 0.2 0.4 0.9 1.6 2.2 3.9 5.2
TP, TPD 80-340/4 0.1 0.1 0.3 1.0 1.6 3.2 - TP 200-540/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 80-410/4 0.1 0.1 0.5 1.2 1.8 3.4 - TP 200-600/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 80-460/4 0.1 0.1 0.6 1.3 1.9 3.5 - TP 200-680/4 0.1 0.1 0.1 0.8 1.4 3.1 4.4
TP, TPD 80-510/4 0.1 0.2 0.7 1.5 2.0 3.6 - TP 200-770/4 0.1 0.2 0.7 1.4 2.0 3.7 5.0
TP 100-40/4 1.4 1.6 2.1 2.9 3.4 5.1 - TP 300-230/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP 100-80/4 1.2 1.4 1.9 2.7 3.2 4.9 - TP 300-270/4 0.7 0.9 1.3 2.3 2.8 4.4 5.7
TP, TPD 100-100/4 0.1 0.1 0.2 0.9 1.5 3.1 - TP 300-360/4 0.7 0.9 1.3 2.3 2.8 4.4 5.7
TP, TPD 100-130/4 0.1 0.1 0.3 1.0 1.6 3.2 - TP 300-370/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP, TPD 100-150/4 0.1 0.1 0.6 1.3 1.9 3.5 - TP 300-440/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP, TPD 100-170/4 0.1 0.1 0.6 1.3 1.9 3.5 - TP 300-550/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP, TPD 100-200/4 0.1 0.1 0.4 1.1 1.7 3.3 4.6 TP 300-630/4 0.8 1.0 1.4 2.4 2.9 4.5 5.8
TP, TPD 100-240/4 0.1 0.1 0.6 1.3 1.9 3.5 4.8 TP 300-640/4 0.7 0.9 1.3 2.3 2.8 4.4 5.7
TP, TPD 100-260/4 0.6 0.8 1.3 2.1 2.7 4.3 5.6 TP 300-750/4 0.7 0.9 1.3 2.3 2.8 4.4 5.7
TP, TPD 100-290/4 0.5 0.7 1.2 2.0 2.5 4.1 5.4 TP 350-400/4 2.0 2.2 2.6 3.6 4.1 5.7 7.0
TP, TPD 100-340/4 0.6 0.8 1.3 2.0 2.6 4.2 5.5 TP 350-450/4 2.0 2.2 2.6 3.6 4.1 5.7 7.0
TP, TPD 100-350/4 0.2 0.4 0.9 1.7 2.3 3.9 5.2 TP 350-540/4 2.0 2.2 2.6 3.6 4.1 5.7 7.0
TP, TPD 100-390/4 0.7 0.9 1.4 2.1 2.7 4.3 5.6 TP 350-680/4 2.0 2.2 2.6 3.6 4.1 5.7 7.0
TP, TPD 100-470/4 0.9 1.1 1.6 2.3 2.9 4.5 5.8
TP 100-560/4 0.1 0.3 0.7 1.7 2.2 3.8 5.1
TP 125-80/4 0.1 0.1 0.1 0.8 1.4 3.0 -
TP 125-110/4 0.1 0.1 0.2 0.9 1.5 3.1 -
TP 125-135/4 0.1 0.1 0.3 1.1 1.6 3.3 -
TP, TPD 125-130/4 0.1 0.1 0.3 1.0 1.6 3.2 -
TP, TPD 125-160/4 0.1 0.1 0.3 1.1 1.6 3.2 -
TP, TPD 125-200/4 0.1 0.1 0.2 0.9 1.4 3.1 -
TP, TPD 125-230/4 0.1 0.1 0.4 1.1 1.7 3.3 -
TP 125-220/4 0.1 0.1 0.4 1.1 1.7 3.3 4.5
TP, TPD 125-280/4 0.1 0.1 0.4 1.1 1.7 3.3 4.5
TP, TPD 125-340/4 0.1 0.1 0.5 1.2 1.8 3.4 4.6
TP, TPD 125-365/4 0.3 0.5 1.0 1.7 2.3 3.9 5.2
TP, TPD 125-420/4 0.1 0.1 0.3 1.0 1.6 3.2 4.5

221
29 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

29. Key application data


Key application data

Dear customer, if you need an ATEX certificate or if you cannot select the pump on the basis of the guidelines in
section 5. Pumped liquids on page 20, please fill in the following form in cooperation with a Grundfos representative.
This will help to ensure that Grundfos supplies you with a pump solution adapted to meet exactly your needs in terms
of pump type, pump materials, shaft seal type, elastomers and accessories.
Customer information
Company name: Project title:
Customer number: Reference number:
Phone number: Customer contact:
Fax number:
Email address:

Quotation made by:


Company name: Prepared by:
Phone number: Date: Page 1 of
Fax number:
Quotation number:
Email address:

Operating conditions
Pumped liquid
Type of liquid:
Chemical composition, if available:
Distilled or demineralised water? Yes: No:
Conductivity of distilled/demineralised water: [μS/cm]
Minimum liquid temperature: [°C]
Maximum liquid temperature: [°C]
Vapour pressure of liquid: [bar]
Liquid concentration: %
Liquid pH value:
Dynamic liquid viscosity: [cP] = [mPa s]
Kinematic liquid viscosity: [cSt] = [mm2/s]
Liquid density: [kg/m3]
Specific heat capacity of liquid: [kJ/(kg·K)]
Air or gas in liquid? Yes: No:
Solids in liquid? Yes: No:
Contents of solids in liquid, if available: % of mass
Additives in liquid? Yes: No:
Does the liquid crystallise? Yes: No:
When does crystallisation happen?

Does the liquid get sticky when volatiles evaporate from the pumped liquid? Yes: No:
Description of 'sticky' circumstances:

Is the liquid hazardous or poisonous? Yes: No:


Special measures to be taken into account when dealing with this hazardous or poisonous liquid:

Special measures for handling this liquid:

CIP liquid, cleaning-in-place


Type of liquid:
Chemical composition, if available:
Liquid temperature during operation: [°C]
Maximum liquid temperature: [°C]
Vapour pressure of liquid: [bar]
Liquid concentration: %
Liquid pH value:

222
TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D
29

Key application data


Pump sizing
Main duty point: Q: [m3/h] H: [m]
Maximum duty point: Q: [m3/h] H: [m]
Minimum duty point: Q: [m3/h] H: [m]

Ambient operating conditions


Ambient temperature: [°C]
Altitude above sea level: [m]

Pressure
Minimum inlet pressure: [bar]
Maximum inlet pressure: [bar]
Outlet pressure, inlet pressure and head: [bar]

ATEX marking

Required marking of the pump


Customer's equipment group, e.g. II:
Customer's equipment category, e.g. 2, 3:
Gas, G, and/or dust, D: Gas (G): Dust (D): Gas and dust (G/D):

Required marking of the motor


Protection type, e.g. d, de, e, nA:
Maximum experimental safe gap, e.g. B, C:
Temperature class
– gas, e.g. T3, T4, T5:
– dust, e.g. 125 °C: [°C]

Description/sketch
Detailed description of ATEX application
Attach a drawing, if possible:

ATEX certificate required Yes: No:

Frequency converter
Frequency converter option wanted? Yes: No:
Control parameter: Pressure: Temperature: Flow rate: Other:
Detailed description of requirements
Attach a drawing, if possible:

System information
Please provide us with information about your system
and a simple sketch if possible. This gives us an idea
as to whether you need accessories or monitoring
equipment, or whether you already have a suitable
system which makes it unnecessary to attach any
further equipment.

223
30 TP, TPD, TPE, TPE2, TPE2 D, TPE3, TPE3 D

30. Grundfos Product Center


Grundfos Product Center

Online search and sizing tool to help you


make the right choice.

http://product-selection.grundfos.com

"SIZING" enables you to "REPLACEMENT" enables you to find a


size a pump based on replacement product.
entered data and Search results will include information on the
selection choices. following:
• the lowest purchase price
• the lowest energy consumption
• the lowest total life cycle cost.

"CATALOGUE" gives you "LIQUIDS" enables you to find pumps


access to the Grundfos designed for aggressive, flammable
product catalogue. or other special liquids.

All the information you need in one place Downloads


Performance curves, technical specifications, pictures, dimensional drawings, motor On the product pages, you can download
curves, wiring diagrams, spare parts, service kits, 3D drawings, documents, system parts. installation and operating instructions, data
The Product Center displays any recent and saved items - including complete projects - booklets, service instructions, etc. in PDF format.
right on the main page.

224
225
ECM: 1220122
V7152685 1217

GRUNDFOS A/S

www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. © Copyright Grundfos Holding A/S

You might also like