0% found this document useful (0 votes)
449 views2 pages

Bernstein D-Su2vks90 PDF

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 2

Technical Data

Metal Switches
Series D

Description D-SU2 VKS 90GR Article number 6142200765

Operating symbol

Operating diagram

Self arresting off 38°

Tolerances
Operating point: ± 3,5°;
ON OFF Operating torque: ± 10%

Electrical data
Rated insulation voltage Ui 400 VAC
Conv. thermal current Ithe 10A
Rated operational voltage Ue 240V
Utilization category AC-15, Ue /Ie 240V/3A
Short-circuit protective device Fuse 2A gL/gG
Protection class I

This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for
defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to
change without notice!

Date of issue: 09.11.2005 / Page 1 of 2


Document: 6142200765_en / Last update: 1 / 2961-05

Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein-ag.de


Vorlage : 0850174282 Orig. 1
Technical Data
Metal Switches

Mechanical data
Enclosure Die-cast aluminium
Cover Sheet aluminium
Actuator Lever (St)
Ambient air temperature -30°C ... +80°C
Contact type 2 NO, 2 NC
6
Mechanical life 1 x 10 operating cycles
Switching frequency ≤ 50 / min.
Assembly 4 x M5
Connection 8 screw terminals (M3,5)
Conductor cross-sections Solid: 0,5 ... 1,5mm²
Litz wire with ferrules: 0,5 ... 1,5mm²
Cable entrance 2 x M20x1,5
Weight ≈ 0,4 kg
Installation position Operator definable
Protection type IP65 acc. to IEC/EN 60529

Actuation
The actuating device is preferably started from 2 sides.
By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation
directions are possible.
The actuation assembly is to be again fastened to the housing using the 4 screws.

Standards VDE 0660 T100, DIN EN 60947-1, IEC 60947-1


VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1

EU Conformity

Approvals CCSAUS A300 (same polarity)

Notes
The degree of protection specified (IP code) applies only to a properly closed cover and the use of an equivalent
cable gland with adequate cable.

This document will not become the contractual basis; the details included herein do not constitute any descriptions of expected conditions, so that warranties/claims for
defects on account of possible variations of the actual qualities from the qualities described herein are explicitly excluded. All rights reserved. Specifications subject to
change without notice!

Date of issue: 09.11.2005 / Page 2 of 2


Document: 6142200765_en / Last update: 1 / 2961-05

Bernstein AG, Tieloser Weg 6, D-32457 Porta Westfalica, Germany / www.bernstein-ag.de


Vorlage : 0850174282 Orig. 1