TrackSwitch A400 “elite”
Bucket Elevator Belt Misalignment System
Detects Tracking and Alignment Problems on Bucket Elevators
Non-contacting System: easy on-site
installation and no moving parts for long-term
reliability
Two independent circuits: can monitor two
separate elevators.
Two different outputs: Relay contacts and
RS485 (PLC/PC)
Test feature: for simple system testing.
Your Material Handling Specialists!
4B COMPONENTS LIMITED
7 2 9 S a b r i n a D r i v e • E a s t P e o r i a , I l l i n o i s 6 1 6 1 1 U S A • Te l e p h o n e 3 0 9 . 6 9 8 . 5 6 1 1 • F a x 3 0 9 . 6 9 8 . 5 6 1 5
h t t p : / / w w w. g o 4 b . c o m E-Mail:
[email protected]TrackSwitch A400 “elite”
Bucket Elevator Belt Misalignment System
The TrackSwitch A400 “elite” Elevator Belt Monitoring System uses an electronic control unit and high power magnetic sensors
(instead of inherently dangerous rub block sensors) to monitor the alignment of the belt in bucket elevators. Each control unit
incorporates two independent monitoring circuits for early detection of belt misalignment on one or two bucket elevators. The
magnetic sensors detect the position of steel bolt heads or steel buckets as they pass through the sensor’s adjustable magnetic
field. Nuisance/false alarms are tuned out of the system during installation by setting a tolerance window on each sensor, which
allows for normal belt wander. Status lights on the control unit indicate the alignment condition of the belts on the elevators and
internal alarm and shutdown relay contacts provide warnings and automatic elevator shutdown control during severe belt mis-
alignment. An optional plug-in module provides RS485 serial communication for similar devices to be connected on a single
multi-drop loop to a computer or PLC.
Hinged Control Unit Specifications
Polycorbonate
Enclosure
Part Number: A4002V345FC
Power Supply: 110 to 240VAC / 12 to 24VDC
Power Consumption: 10VA / 10 Watts
Fuse: 2A Maximum
LED Indicators Outputs: Alarm - one open contact 8A @ 250VAC
Stop 1- one closed contact 8A @ 250VAC
Stop 2 - one closed contact 8A @ 250VAC
RS485 Module (optional)
Inputs: 4 individual pulsed inputs, 12VDC,
20-4000 per minute.
Sensor Supply: 12VDC, 150mA
Protection: IP65 NEMA 4, 4X
Test Activation Approvals: FM and CSA Class 2 Div.1 - Pending
ATEX (Europe) - Pending
Height x Width x Depth 9.7” x 7.4” x 4”
Elevator Leg Weight: 3 lbs.
Sensors: FM & CSA Approved Class 2 Div.1
12VDC. Adjustable magnetic range 1-4”
Bolts
Belt
Belt Elevator Leg
Bolts
Typical sensor arrangement with plastic buckets
Approved Installation/Start Up Service Available
24-Hour Hotline at Peoria Office Typical sensor arrangement with steel buckets
Data Sheets and Manual Available Upon Request
Brochure information subject to change or correction. February 2000