0% found this document useful (0 votes)
110 views1 page

Built-In PLC Programming in FD11 Controller: Step-1: Changing Protecting Level From USER To SPECIALIST

The document provides steps for connecting and programming the built-in PLC in an FD11 controller. The steps include: 1) changing the protection level to specialist, 2) connecting the built-in PLC, 3) mapping inputs and outputs, 4) changing the protection level back, 5) creating a ladder logic program using inputs X0-X31 and outputs Y0-Y31, and 6) monitoring the ladder program.

Uploaded by

Sam Jesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
110 views1 page

Built-In PLC Programming in FD11 Controller: Step-1: Changing Protecting Level From USER To SPECIALIST

The document provides steps for connecting and programming the built-in PLC in an FD11 controller. The steps include: 1) changing the protection level to specialist, 2) connecting the built-in PLC, 3) mapping inputs and outputs, 4) changing the protection level back, 5) creating a ladder logic program using inputs X0-X31 and outputs Y0-Y31, and 6) monitoring the ladder program.

Uploaded by

Sam Jesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Built-in PLC Programming in FD11 Controller

 Connect built-in PLC


 I/O mapping
 Ladder Programming

Step-1: Changing Protecting Level from USER to SPECIALIST


Press “R” key  type 314-changing protecting level  Enter the Password “12345” Enter

Step-2: Connecting in-build PLC


Constant settings  (1)Control Constants  (6)Built-in PLC  Select “RUN” with Enable Key 
Complete  R

Step-3: I/O Mapping


Constant settings  (6)Signals  (15)Hardware settings 
 Inputs & Outputs are in Robot programm Control
Inputs & Outputs are in PLC programm Control
 Complete  OK  Turn Off Controller  And after 20 seconds Switch ON the Controller

Step-4: Changing Protecting Level from USER to SPECIALIST


Follow Step-1 procedure again

Step-5: Ladder Programming


Service Utilities  (14) PLC programm edit  (1)PLC programm edit  Open (or) Create a File
 Execute  Design a ladder logic  Enter the Address X0 – X31 (INPUTS), Y0 – Y31(OUTPUTS)
 Change Menu  Save  Complete  Yes  Execute  Yes  OK  R

Step-6: Ladder Monitor


Monitor 2  (32) PLC  (3) Ladder Monitor