Costing Calculations:: Enquiry 270 - I

This document provides a costing calculation for an IMC-1 structure located in NCR. It details the structural components, their weights, costs and totals over 20 lakh for the supply portion. Installation charges would add another 12 lakh. Key components include built-ups weighing over 130 tonnes, cold formed sections weighing around 38 tonnes and roof and wall cladding of over 7100 square meters.

Uploaded by

Rakesh Sharma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
171 views7 pages

Costing Calculations:: Enquiry 270 - I

This document provides a costing calculation for an IMC-1 structure located in NCR. It details the structural components, their weights, costs and totals over 20 lakh for the supply portion. Installation charges would add another 12 lakh. Key components include built-ups weighing over 130 tonnes, cold formed sections weighing around 38 tonnes and roof and wall cladding of over 7100 square meters.

Uploaded by

Rakesh Sharma
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 7

COSTING CALCULATIONS: LOCATION: NCR DATE:

REVISION: 0
CLIEN ENQUIRY 270 - IMC-1

ENQUIRY 270 - I 25 feet 5000 22 110000 16500 126500

45 feet 3500 1 3500 420 3920

RAFTER 0 0 0

0 0

EXCISE
STRUCTURAL COMPONENTS WEIGHT UNIT RATE VALUE CESS(%) SALES TAX (%) TOTAL VALUE
DUTY(%)

WEIGHT OF BUILT-UPS = 130420 75.00 9,781,500.00 0 0 0 9,781,500.00


END WALL COLUMN 4200 75.00 315,000.00 0 0 0 315,000.00
STAIR CASE 18 NOS. 0 75.00 0.00 0 0 0 0.00
ANCHOR BOLT = 5385 75.00 403,860.00 0 0 0 403,860.00
STUD PIPE 7425 75.00 556,875.00 0 0 0 556,875.00
MONITOR 2 MTR. WIDE 75.00 0.00 0 0 0 0.00
RAILING 50X50 SQR 75.00 0.00 0 0 0 0.00
CADGE LEDDER 75.00 0.00 0 0 0 0.00
CANOPY 75.00 0.00 0 0 0 0.00
CANOPY 6 MTR. WIDE 2 NOS. 75.00 0.00 0 0 0 0.00
WEIGHT OF COLDFORMS = 37804 75.00 2,835,285.06 0 0 0 2,835,285.06
WEIGHT OF ACCESSORIES = 15122 75.00 1,134,114.03 0 0 0 1,134,114.03
WEIGHT OF DECKING = 0 75.00 0.00 0 0 0 0.00
WEIGHT OF HARDWARES = 3213 120.00 385,586.71 0 0 0 385,586.71

TOTAL WEIGHT = 203568 (Kg) TOTAL VALUE = 15,412,220.80


SHEET METAL
SHEETING COMPONENTS AREA UNIT RATE VALUE EXCISE DUTY(%) CESS(%) SALES TAX (%) TOTAL VALUE
ROOFING = HIGH RIB 0.47 7816 380.00 2,970,169.02 0 0 0 2,970,169.02
SIDE CLADDING = HIGH RIB 0 3409 380.00 1,295,508.16 0 0 0 1,295,508.16
SKYLIGHT = POLY SHEET 2 MM THK. 391 850.00 332,189.96 0 0 0 332,189.96
CLADDING POLY SHEET 2 MM THK. 0 376.60 0.00 0 0 0 0.00
LOUVERS 1500X3000 4 NOS. 0 0.00 0.00 0 0 0 0.00
FLASHINGS = CAZ (SQM) 1347 400.00 538,822.38 0 0 0 538,822.38
DOWN TEK PIPE CAZ (SQM) 461 400.00 184,520.00 0 0 0 184,520.00
VALLEY GUTTER & D/P 4MM THK. FIBER SHEET IN MTR. 0 0.00 0.00 0 0 0 0.00
S RIDGE VENT 600 IN RMTR. 0 5500.00 0.00 0 0 0 0.00
FOAM CLOSURE (LENGTHWISE) (NOS.) 0 0.00 0.00 0 0 0 0.00

TOTAL AREA = 7106 (Sqm) 3.4 (Kg/Sq Ft) TOTAL VALUE = 5,321,209.51
CALCULATION OF FRIEGHT
ENQUIRY 270 - IMC-1 259614.79
WEIGHT OF SHEETING = 56.05 84.86
WEIGHT OF STRUCTURES = 203.5683 76456.9823

lsscindia.com
TOTAL WEIGHT = 259.6148

NUMBER OF TRUCKS REQUIRED =


FREIGHT PER TRUCK = 0
TOTAL FREIGHT = 0

TOTAL VALUE = 20,733,430

ADD 10 PERCENT :

PRICE TO QUOTE = 20,733,430


INSTALLATION CHARGES

INSTALLATION OF STRUCTURES& SHEETING = @ 5 1,298,074

TOTAL COST = 22,031,505


COST PER SQUARE FEET (SUPPLY) = 272

TOTAL = 288.15557

Basic Building Dimensions : LOCATION: NCR


ENQUIRY 270 - IMC-1

Building Type IMC-1 Revision = 0 300


Width = 43.13 Length O/O = 164.75 m C/C 150
Roof slope = 1:10 Eaves ht. = 30
Bay Spacing= 7.845 m Clear Height = 9.45 m
NO. OF BAYS = 21
End Bay number = 8
End Bay sp. = 5.391 m Max rafter depth= 0.60 m
Purlin spacing = 1.5 m No. of braced bay= 0.00
Girt spc. = 1.5 m Base Condition PINNED
FEW Brick Wall ht. = 3.00 m BUILDING CONDITION ENCLOSED
BEW Brick Wall ht. = 3.00 m Built-up Material Yeild Stress 345.00 MPa
LSW Brick Wall ht. = 3.00 m Cold Formed Material Yeild S 345.00 MPa
RSW Brick Wall ht. = 3.00 m SKYLIGHT SHEETS 4 % OF ROOF AREA
Wind Speed = 47 m/s

Roof cladding material: HI RIB


Wall cladding material: HI RIB
CRANE CAPACITY 20 TONS 1 CRANE IN EACH WIDTH MODULE
CRANE BRACKET HEIGHT 8 m
MEZZANIANE AREA 0 m (W) 0.00 m (L) = 0.00
MEZANIANE DEAD LOAD 0 KN/SQM
MEZANIANE LIVE LOAD 0 KN/SQM
MEZZANIANE GRID 0 MX 0M

lsscindia.com
BUILDING CONDITION ENCLOSED
Design Code MBMA 2012 Additional Important Notes to be followed
Deflection Limit Span/180 Eh/100 1
Dead load on roof= 10 Kg/m² 2
Live Load 57 Kg/m² 3
Collateral load on roof= 0 Kg/m² 4
Roof Purlin Size, Z 200 1.6 5
Girt Size, Z 200 1.65 6

Cross - Sectional Reference

lsscindia.com
lsscindia.com
495

lsscindia.com
TEST
7.5 7.5 43.13 58.13 38.75333 5
8 9 0.00 17 11.33333 5

D
7 7 30.00 44 29.33333 5
8 8 0.00 16 10.66667 5
164.75 31923.06
43.13 2444.033
34367.09
3436.709
37803.8

#REF! #REF!
#REF! #REF!
#REF!
#REF!
#REF!

You might also like