D7700H en PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

Connection blocks type HMP with integrated lifting and

lowering function for proportional spool valves


type PSL and PSV, size 2 and 3
Baxic data Additional technical information:
Design Connection blocks for valve bank design Size Design Pamphlet
Pressure pmax 250 bar
Flow Qmax 160 lpm 2 Manifold mounting design D 7700-2
2 Valve bank design
(directly mounted CAN-controls) D 7700 CAN
3 Valve bank design D 7700-3

1. General information
Connection blocks type HMP were developed especially for
the actuation of single rod cylinders, especially in hoists of e.g.
counter balanced trucks.
In this way several consumers may be moved simultaneously,
independently from each other at different velocity and pressure
ratings, as long as the sum of the partial flows needed for this is
within the total delivery supplied by the pump.
The lift/lower function is controlled by proportional 2/2-way ball Directional spool
seated directional valves type EMP. valve section with
These valves do not need an external supply of control oil. End plate ancillary block Connection block
The load pressure is transmitted to the LS chain during lifting
movements.

Benefits:
o High flow rates for all functions due to hydraulically piloted
valves
o Low loss and compact design
o Low power consumption of the pump drive (electric/fuel)
o Minimized heat generation reducing the thermal stress of al
components
o Suited for both constant flow or variable displacement pump
systems
o Extremely sensitive controls at all functions 2.1
o Zero leakage seated valve technology for lifting/lowering
function
o No pilot pressure required for lowering (no pump start)

Flexibility:
Modular products for tilting and additional functions based on
PSL/PSV range:
o Simple extension for more additional functions
o Optional inflow controllers and pressure limitations to be
defined for each section
o Additional functions (e.g. over-center valves etc.) can be
integrated via ancillary blocks mounted onto the valve
sections

Table of contents
1. General information ................................................. 1 5. Unit dimensions ........................................................9
2. Type coding, overview ............................................. 2 6. Appendix ................................................................. 10
3. Available version, main data ................................... 3 6.1 Safety notes ............................................................. 10
3.1 Connection block ...................................................... 3 6.2 Transport and storage............................................... 10
3.1.1 HMPL ......................................................................... 3 6.3 Installation................................................................. 10
3.1.2 HMPV ......................................................................... 4 6.4 Application examples ................................................ 10
3.1.3 Dampening elements for the connection block ........ 5
3.2 Actuations .................................................................. 5
4. Characteristic data .................................................. 6
4.1 General and hydraulic ................................................ 6
4.2 Curves ........................................................................ 7

HAWE Hydraulik SE D 7700-H


STREITFELDSTR. 25 • 81673 MÜNCHEN Connection blocks type HMP

© 2010 by HAWE Hydraulik July 2012-02


D 7700-H page 2

2. Type coding, overview


Order coding example:

HMPL 5 S 1 Z / PVPV / 250 – 3 - A 2 O 63/40 A 220 B 150 / E/3 AL - 6 - B 7/250


- A 2 L 25/16 / E/3 AN 320 BN 320
- E 1 – G 24

; < = > ? @ A B C

; Basic type code for the connection block


HMPL Supply with pressurized oil by means of ?
Optional 2/2-way solenoid valve for arbitrary idle pump
constant delivery pump (open center) circulation (acc. to table 6, sect. 3.1.3)
HMPV Supply with pressurized oil by means of (no coding) Without directional valve, but prepared for
variable displacement pump (closed retrofitting
center) Z De-energized open = idle pump circula-
tion when valve is de-energized
V De-energized closed = idle pump circula-
< Tapped ports P, R and H acc. to ISO 228/1 (BSPP) tion when valve is energized
4 G 3/4“ for size 2
UNF 4 1 1/16-12UN-2B (SAE-12) for size 2 @ 2/2-way directional seated valves (for add. Information see
5 G 1“ for size 3 D 7490/1) (see table 7)
UNF 5 1 5/16-12UN-2B (SAE-20) for size 3 PVPV Lifting = EMP / Lowering = EMP
VPV Lifting = EM / Lowering = EMP
PVV Lifting = EMP / Lowering = EM
= Additional elements
S, W Additional dampening element in the
LS-line A Tool adjustable pressure limiting valve (main pressure
B, B 4...7 Orifice in the LS-line limitation) in the connection block
G Restrictor check valve /... Pressure setting ... (bar)
U Automatic reduction of the pump circula-
tion pressure via by-pass valve B Size (hole pattern for mounting subsequent directional
spool valves type PSL)
> Control oil supply 2 size 2 (see D 7700-2)
(no coding) Without pressure reducing valve in case of 3 size 3 (see D 7700-3)
an external control oil supply (min. 20 bar
up to max. 40 bar)
1 With integrated pressure reducing C Valve sections and end plates acc. to D 7700-3 and
valve for the internal supply of control oil D 7700-2
(control pressure approx. 20 bar)
2 With integrated pressure reducing
valve for the internal supply of control oil
(control pressure approx. 40 bar)
D 7700-H page 3

3. Available version, main data


3.1 Connection blocks
There are two basic variations of connection blocks:
o Connection blocks with integrated 3-way flow controller, suitable for a constant delivery pump system (open-center)
- type HMPL (sect. 3.1.1)
o Connection blocks suited for a variable displacement pump system (closed center), a constant pressure systems, or if a second
or more, separately located directional spool valve banks are fed in parallel
- type HMPV (sect. 3.1.2)
Order coding for a connection block as single section (examples): HMPL 5 S1 / PVPV /200 - 3 AMP 12
(Attention: Size specification absolutely necessary, here 3) HMPV 5 B1 Z / PVPV /250 - 3 - G 24

3.1.1 Connection blocks for constant delivery pump systems (with integrated 3-way flow controller) type HMPL
Order example: HMPL 5 U S 1 V / PVPV/250 - 3 - … - G 24
Table 1 Table 9
Table 2 Valve sections size 2 (acc. to D 7700-2) or
size 3 (acc. to D 7700-3)
Table 5
Size
Table 6
Table 8
Table 7
Table 1: Basic type and port size

Coding Ports P, R and H Max. pump Description


conf. ISO 228/1 delivery flow
(BSPP) (lpm)
HMPL 4..-2 G 3/4
approx. 80 Supply with pressurized oil by means of constant delivery pump
HMPL UNF 4..-2 1 1/16-12UN-2B (open center) for size -2
(SAE-12)
Like HMPL 4 but with automatic reduction of the idle pump
HMPL 4 U..-2 G 3/4 approx. 100 circulation pressure via a by-pass valve
Qpu Ú 60 lpm for version with solenoid actuation
HMPL 5..-3 G1
Supply with pressurized oil by means of constant delivery pump
HMPL UNF 5 1 5/16-12UN-2B approx. 160 (open center) for size -3
(SAE-20)
HMPL 5 U..-3 G1
Like HMPL 5 but with automatic reduction of the idle pump
approx. 160 circulation pressure via a by-pass valve
HMPL UNF 5 U..-3 1 5/16-12UN-2B
Qpu Ú 80 lpm for version with solenoid actuation
(SAE-20)
Symbole

“V” “Z” HMPL .. / PVPV /..- HMPL . U .. / PVPV /.. -


HMPL UNF .. / PVPV /..-

Table 2: Coding for dampening of the LS-signal

Coding Description

S Standard (integrated combination of orifice, check valve, pre-load valve pre-load pressure approx. 25 bar)
W wie Serie, jedoch verstärkte Drosselwirkung
G Restrictor check valve (without pre-load valve), increased throttling effect,
not avail. with type HMPL.U
B With orifice # 0.8 mm within LS-duct (to limit control oil flow)
B 4, B 5,
B 6, B 7 With orifice # 0.4 mm, 0.5 mm, 0.6 mm or 0.7 mm at the LS-duct

Note: Do not operate without dampening element otherwise malfunction of the pressure limiting valve.
D 7700-H page 4

3.1.2 Connection blocks for variable displacement pump systems / constant pressure system or for additional parallel
connected but separately mounted directional spool valves without inflow controller (type HMPV/PSV)

Order example: HMPV 5 B 1 V /PVPV/250 – 3 - … – G 24


Table 3 Table 9
Table 4 Valve sections size 2 (acc. to D 7700-2) or size 3
(acc. to D 7700-3)
Table 5
Size
Table 6
Table 8
Table 7

Table 3: Basic type and port size

Coding Ports P, R and H Max. pump Description


and size conf. ISO 228/1 delivery flow
(BSPP) (lpm)

HMPV 4..-2 G 3/4


100 Supply with pressurized oil by means of variable displacement
HMPV UNF 4..-2 1 1/16-12UN-2B pump (closed center) with pressure/flow controller for directional
(SAE-12) valves size -2

HMPV 5..-3 G1 Supply with pressurized oil by means of variable displacement


pump (closed center) with pressure/flow controller for directional
HMPV UNF 5 1 5/16-12UN-2B 160 valves size -3
(SAE-20)

Symbole

HMPV 4 .. / PVPV /..- 2 HMPV 5 .. / PVPV /.. - 3


HMPV UNF 4 .. / PVPV / ..- 2 HMPV UNF 5 .. / PVPV / ..- 3

Table 4: Coding for dampening of the LS-signal

Coding Description

S Standard (integrated combination of orifice, check valve, pre-load valve pre-load pressure approx. 25 bar)

W Like S, but with increased throttle effect


B With orifice # 0.8 mm within LS-duct (to limit control oil flow)

B 4, B 5 With orifice # 0.4 mm, 0.5 mm, 0.6 mm or 0.7 mm at the LS-duct
B 6, B 7

Note: Do not operate without dampening element otherwise malfunction of the pressure limiting valve.
D 7700-H page 5

3.1.3 Additional elements for connection blocks

Table 5: Coding for control oil supply

Coding Description

no coding Without pressure reducing valve for manual or pneumatic actuation or with external control oil supply
(20...40 bar)
With integrated pressure reducing valve for internal control oil supply for actuations H(HA), HEA).. and E(EA)..
1
or as pick-up for other control valves (max. permissible control oil flow approx. 2 lpm)
Control pressure: Coding 1: approx. 20 bar (+ return pressure at R) = standard
2
Coding 2: approx. 40 bar (+ return pressure at R)

Table 6: Arbitrary idle pump circulation of all consumers by means of 2/2-way solenoid valve acc. to D 7490/1

Coding Description
no coding (prepared for retrofitting)
Z With type EM 11 S, idle pump circulation if valve is de-energized (emergency stop)

ZM Like Z, but with lead sealed wing screw for emergency operation

V With type EM 11 V, idle pump circulation if valve is energized

Table 7: Lifting and lowering function

Coding Description 2/2-way directional seated valves acc. to D 7490/1


Size 2 Size 3
Lifting Lowering Lifting Lowering
/PVPV Lifting and lowering proportional EMP 31 V 80 EMP 31 V 80 EMP 41 V EMP 41 V
/PV 100 PV 100 Lifting and lowering proportional EMP 31 V 100 EMP 31 V 100

/PVV Lifting proportional, lowering EMP 31 V 80 EM 31 V EMP 41 V EM 41 V
ON/OFF
/VPV Lifting ON/OFF, lowering propor- EM 31 V EMP 31 V 80 EM 41 V EMP 41 V
tional
Note: Maintaining the lifted position via zero leakage seated valve technology.
The switching time strongly depends of flow, pressure and viscosity.
Drop rate braking valves on the consumer side are recommended if the drop rate shall be limited. There is an
emergency drain valve (allan key a/f 5) enabling controlled lowering, when necessary.

Table 8: Tool adjustable pressure limiting valve for the main pressure.

Coding Description

/... Pressure specification in bar (piloted main pressure limiting valve)

3.2 Actuations
Table 9: Solenoid voltage (electrical actuation)

Coding Nom. voltage Description

G 12, X 12 12 V DC Standard, electr. connection conf. EN 175 301-803 A,


G 24, X 24 24 V DC with (plug G...) or without (plug X...)

AMP 12 K4 12 V DC All valves at the connection block feature 2 terminals whereas the directional spool valve
AMP 24 K4 24 V DC actuations (acc. to D 7700-2 and D 7700-3) show 4 terminals

For plugs, see pamphlet D 7163


D 7700-H page 6

4. Characteristic data
4.1 General and hydraulic

Type coding HMPL, HMPV see sect. 3.1


Design Connection block for combination with up to 12 directional spool valves as valve bank,
all-steel design
Mounting Tapped holes: M8; see dimensions
Installation position Arbitrary
Ports P = Pressure inlet (pump) / lead-on
R = Return
H = Consumer ports
M = Pressure gauge connection (pump side)
LS = Load sensing pressure port e.g. for pump controller
Attention: No pressure input!
Ports acc. to type and size
Surface coating All surfaces corrosion-inhibiting, gas nitrided
EM solenoids at actuation acc. to D 7490/1
Mass (weight) approx. size -2: 4.9 kg; size -3: 5.8 kg
Pressure fluid Hydraulic fluid acc. to DIN 51524 table 1 to 3; ISO VG 10 to 68 acc. to DIN 51519
Viscosity range: min. approx. 4; max. approx. 1500 mm2/s
Optimal operation range: approx. 10...500 mm2/s
Also suitable are biologically degradable pressure fluids of the type HEPG (Polyalkylen-
glycol) and HEES (synth. Ester) at operation temperatures up to approx. +70°C. HETG
(e.g. rape seed oil) or water based fluids e.g. HFA or HFC must not be used!
Temperature Ambient: approx. -40 ... +80°C ; Oil: -25 ... +80°C, pay attention to the viscosity range!
Start temperature down to -40°C are allowable (Pay attention to the viscosity range during
start !), as long as the operation temperature during consequent running is at least 20K
higher.
Biological degradable pressure fluids: Pay attention to manufacturer‘s information. With
regard to the compatibility with sealing materials do not exceed +70°C.
Restrictions with explosion-proof solenoids
Required cleanliness min. NAS 1638 Classe 8 or ISO 4406 Classe 20/17/14
Operating pressure P: pmax = 250 bar; H: pmax = 280 bar; R: pmax = 10 bar;
End plates E 1, E 2, E 3 etc. with additional leakage port when higher return pressure is
anticipated.

4.2 Electrical
Note: Dither and PWM signals are important for optimizing the characteristic and for minimizing the hysteresis

- Coding V (size 2) - Coding PV (size 2)


- Coding V (size 3)

Add. documentation D 7490/1 (type EM 31 V) Add. documentation D 7490/1 (type EMP 31 V, EM 41 V)


Nom. voltage UN 24 V DC 12 V DC Nom. voltage UN 24 V DC 12 V DC

Nom. power PN 21 W 21 W Nom. power PN 32 W 32 W

Nom. current IN 0.63 A 1.2 A Nom. current IN 1.25A 2.5 A

- Coding PV (size 3) Circuitry Circuitry


with coding -G 12, -G 24, with coding -AMP 24
-X 12, -X 24 AMP Junior Timer
Add.documentation D 7490/1 (type EM 41 V) EN 175 301-803 A 2-pin
IP 65 (IEC 60529) IP 65 (IEC 60529)
Nom. voltage UN 24 V DC 12 V DC

Nom. power PN 30 W 30 W

Nom. current IN 1.25 A 2.5 A

For data of the solenoids for the directional spool valve sections, see D 7700-2 (size 2) or D 7700-3 (size 3)
D 7700-H page 7

4.3 Curves Oil viscosity during measurement approx. 50 mm2/s

Size 2
Pressure limiting valve at the connection block Circulation pressure P d R
PdR

Back pressure |p (bar)


Pressure setting (bar)

Flow Q (lpm) Flow Q (lpm)

Size 3
Pressure limiting valve at the connection block Circulation pressure Pd R
PdR Back pressure |p (bar)
Pressure setting (bar)

Flow Q (lpm) Flow Q (lpm)

Size 2
Lifting, back pressure (valve 100% open) Lowering, back pressure (valve 100% open)
PdH HdR

EM 31V EM 31V
Back pressure |p (bar)

Back pressure |p (bar)

EMP 31V80 EMP 31V80

EMP 31V100 EMP 31V100

Flow Q (lpm) Flow Q (lpm)


D 7700-H page 8

Size 3
Lifting, back pressure (valve 100% open) Lowering, back pressure (valve 100% open)
PdH HdR
Back pressure |p (bar)

Back pressure |p (bar)


EMP41V EMP41V

EM41V EM41V

Flow Q (lpm) Flow Q (lpm)


D 7700-H page 9

5. Unit dimensions All dimensions are in mm and are subject to change without notice !
For additional parameters and dimensions, see sect. 4.1
5.1 Type HMPL/HMPV size 2
approx. 102.5
Lifting
Adjustment main
pressure limitation

approx. 75

approx. 229
3x M8, 8 deep
for vertical
installation Emergency
drain a/f 5, 5 Nm

3x M8, 8 deep for


vertical or horizontal
installation
Lowering
Directional spool
Port LS valve sections
at type HMPV open
Ports P, R, H LS, M

HMPL 4..-2 G 3/4 G 1/4 ISO 228/1


HMPV 4..-2 (BSPP)

HMPL UNF 4..-2 1 1/16-12UN-2B 7/16-20UNF-2B SAE J 514


HMPV UNF 4..-2 (SAE-12) (SAE-4)

5.2 Type HMPL/HMPV size 3


approx. 102.5
Idle pump Lifting
circulation

2x M8, 12 deep

approx. 73

approx. 245.5

Lowering

Adjustment main
pressure limitation
Directional spool
valve sections

Emergency drain
a/f 5, 5 Nm

Ports P, R, H LS, M

HMPL 5..-3 G 1 G 1/4 ISO 228/1


HMPV 5..-3 (BSPP)

HMPL UNF 5..-3 1 5/16-12UN-2B 7/16-20UNF-2B SAE J 514


HMPV UNF 5..-2 (SAE-20) (SAE-4)
D 7700-H page 10

6. Appendix
6.1 Safety notes
It is recommended to employ a line rupture protection valve e.g. type LB acc. to D 6990 to safe guard the lifting device. There is
also a version where the line rupture protection valve is designed into a fitting, see SK 6990 E.
Do not operate the connection block without additional dampening element otherwise malfunction of the pressure limiting valve.
It is recommended to employ valves with connection block acc. to D 7490/1 between port H and the lifting cylinder to ensure
redundant functional cut-off of the lowering function.
Unintended lifting may be occur when the load pressure at H drops below the return pressure at R.

6.2 Transport and storage


1 year (stored packed, dry and cool)

6.3 Installation
The mounting of the valve bank must be performed in such a way that no stress is induced. Screws and washers between valve
assembly and bracket are recommended for fastening. Additional mounting at the end plate is recommended for valve banks with
more than 4 valve sections.
Note: Observe 6.3 Notes regarding assembly, installation and conversion in pamphlet D 7700-3

6.4 Application example


Counter balance forklift truck with speed controlled electric motor

Lifting Tilting Add. function 1 Add. function 2

HMPL 4 S 1 / PVPV/250 - Z
- A 2 L 10/10 /E /2 AL - 8 - C 110
- A 2 L 16/16 /E /2
- A 2 L 25/25 /E /2
- E0 - AMP 24 K 4
D 7700-H page 11

Counter balance forklift truck with internal combustion engine and variable displacement pump electric motor

Lifting

Tilting Add. function 1

HMPV 4 S 1 / PVPV/250 - 2
- A 2 L 10/10 /E /2 AL - 8 - C 110
- A 2 L 25/25 /E /2
- E0 - AMP 24 K 4

approx. 200
approx. 230

You might also like