Module 2: Transmission Lines Lecture 5: Standing Waves On Transmission Line & Impedance Transformation
Module 2: Transmission Lines Lecture 5: Standing Waves On Transmission Line & Impedance Transformation
Module 2: Transmission Lines Lecture 5: Standing Waves On Transmission Line & Impedance Transformation
Objectives
Where is the distance measured from the load towards the generator
The result is a 'Standing Wave'. Ofcourse in general it is a partial standing wave since the amplitudes of the two travelling
waves may not be equal.
Figure shows the voltage standing wave on the line. We may note how the nature of the wave changes from 'travelling' to
'standing' when we vary and . (Try different values for )
When , , there is no backward wave and therefore the net wave is the 'Forward Travelling Wave'.
On the other hand when , the wave will be fully standing wave.
Module 2 : Transmission Lines
The only possibility then is, that the forward wave reaches the right end of the line and does not find correct conditions for
transfering the full power to the load impedance. The part of the energy then gets reflected from the load which results into
the 'Backward Wave'.
The strength of the backward wave then should be related to the load impedance with which the line is terminated.
Since the forward wave carrys energy towards the load, we call this wave as the 'Incident Wave'. The backward wave
which carrys reflected energy from the load is called the 'Reflected Wave'. We therefore have
Module 2 : Transmission Lines
Impedance seen at any distance from the load in terms of the ' Reflection Coefficient ' then is
Inverting the relation we get the reflection coefficient at any point on the line which is at a distance from the load is
Now at , the impedance . Therefore the reflection coefficient at the load end of the
line is
Interesting to Note
The transmission line provides a medium of impedance for the energy flow. Any departure from creates an
impedance step. This impedance step disrupts the smooth flow of energy and the part of the energy is reflected.
Larger the impedance step more is the reflected energy and higher the reflection coefficient.
Module 2 : Transmission Lines
and
We therefore get,
Important
Impedance measured at line is not same as and is location dependent.
Impedance seen by the generator for a given load impedance varies a function of the line length and consequently
the power supplied by the generator becomes a function of line length.
Just changing the connecting wires the circuit performance will change.
Module 2 : Transmission Lines
Infact there is nothing special about the load impedance. The impedance transformation can be between any two locations
on the line. It should be remembered however, that the sign convention for the distance on the line must be correctly taken.
-------- (2.3)
-------- (2.4)
It can be noted that the above two expressions 2.3 and 2.4 are same expression with and interchanged and
replaced by
Conclusion
Expression 2.3 is the general impedance transformation relation which can be used for transforming impedance on
one location on the line to the other. If the impedance is transformed to a point towards the generator, is
positive, and if it is transformed to a point away from the generator, is negative.
Module 2 : Transmission Lines
Recap