0% found this document useful (0 votes)
81 views3 pages

Maxwell Technologies, Inc.: Gss Module Sizing Calculator

This document provides instructions for calculating the recommended number of Maxwell GSS modules needed to crank a diesel engine based on engine specifications, temperature, desired cranking time, and other factors. It includes input fields for the user to enter engine details and environmental conditions. The spreadsheet will then provide the estimated number of new and end-of-life modules required to achieve the desired cranking time. Actual results may vary from the calculated values.

Uploaded by

ihiran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views3 pages

Maxwell Technologies, Inc.: Gss Module Sizing Calculator

This document provides instructions for calculating the recommended number of Maxwell GSS modules needed to crank a diesel engine based on engine specifications, temperature, desired cranking time, and other factors. It includes input fields for the user to enter engine details and environmental conditions. The spreadsheet will then provide the estimated number of new and end-of-life modules required to achieve the desired cranking time. Actual results may vary from the calculated values.

Uploaded by

ihiran
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 3

MAXWELL TEC

GSS MODULE
This spreadsheet will compute the number of M
Introduction: calculated estimate based on the information p
coldest temperature, and oil weight).

Actual results may vary from the calculated valu


Disclaimer: Maxwell's best calculated estimate of the numb
number of modules based on the calculated res

1) Enter data in the yellow cells below.


2) Observe units and allowable value ranges
Instructions: 3) All yellow cells must be filled in with the exce
control panel

1) All modules are fully charged by a Maxwell-a


Assumptions: 2) Diesel engine was manufactured within past
3) No excessive cranking load is present beyon

Engine displacement liters


Desired/required cranking time seconds
Starter motor voltage volts
Low voltage cutout of control panel volts
Number of starter motors starters
Coldest expected starting temperature ⁰F
Oil weight W
Recommended
number of modules
required to achieve
desired cranking time
GSS Model Number NEW EOL
GEN 31-900-12V-2T N/A N/A
GEN 31-1800-12V-2T N/A N/A
GEN 31-900-24V-2T N/A N/A
GEN 31-980-24V-2T N/A N/A
XWELL TECHNOLOGIES, INC.
SS MODULE SIZING CALCULATOR
will compute the number of Maxwell GSS modules needed to crank a diesel engine for a specified nu
e based on the information provided (displacement, cranking time, starter voltage, low voltage cutout
e, and oil weight).

vary from the calculated values. Maxwell makes no representation that the values are exact in your
culated estimate of the number of modules needed using the information provided. Maxwell cannot
s based on the calculated results compared to the actual installation requirements.

e yellow cells below.


nd allowable value ranges
must be filled in with the exception of the "Low voltage cutout of control panel" cell which should be le

fully charged by a Maxwell-approved charger (i.e.; La Marche model USC) with temperature sensor
as manufactured within past 20 years and is in good working order with no pre-existing starting diffic
anking load is present beyond that of correctly sized alternator

Enter decimal value of displacement of engine in liters (2.0 - 109.0)


Enter decimal number of seconds of total cranking time desired from ultracapacitors alone
Enter either 12 or 24
Enter low-voltage cutout of control panel if powered by GSS modules; leave cell empty if po
Enter either 1 or 2
Enter an integer value in the range of 0 - 70
Enter first 1 or 2 characters of SAE oil viscosity rating: 5, 10, 15, 20, 30, or 40

EXPLANATION OF RESULTS
1) The calculated number of GSS modules is shown in the green cells to the left.
2) "N/A" is shown for GSS modules not having the same voltage as entered for "Starter mo
3) The values under the column heading of "NEW" are the calculated number of modules n
installation.
4) The values under the column heading of "EOL" are the calculated number of modules w
considered to have reached end of life (EOL) condition.
5) The recommended number of modules assumes that all are identical and connected in