BK4A 001 TS ME6 DS 04 - MDS For Manual Monorail Hoist - Rev0
BK4A 001 TS ME6 DS 04 - MDS For Manual Monorail Hoist - Rev0
BK4A 001 TS ME6 DS 04 - MDS For Manual Monorail Hoist - Rev0
HUNG FIELDS
NOTES :
1) * indicates VENDOR to furnish, specify and confirm data.
2) VENDOR to advise the headroom required for low headroom type hoist.
3) The hoist shall be equiped with overtravel restraint such that before the load can be completely run off the hoist, it shall be restrained in its
maximum positions.
4) Hoist shall be provided with safety latches wherever required.
5) For location and trolley travelling distance refer Equipment Layout BK4A @ EL+16.600 (Doc. No.: BK4A-001-TS-TP1-LD-02) and Piping
Layout Drawing on BK4A @ EL+16.600 (Doc. No.: BK4A-001-TS-TP1-LD-06).
6) This data sheet shall be read in conjunction with Material Handling Study Report (Doc. No.: BK4A-001-TS-ME6-RPT-01).
MODIFICATION AT WHITE TIGER FIELD TO RECEIVE GAS FROM Doc. No BK4A-001-TS-ME6-DS-04
THIEN UNG, DAI HUNG FIELDS
BK4A PLATFORM
Rev. No 0
DATASHEET FOR MANUAL MONORAIL HOIST
Page 3 OF 3
Document Ref.: Material Handling Study Report (BK4A-001-TS-ME6-RPT-01) No. of Units: 1 x 100%
DIMENSIONAL REQUIREMENTS
Hook
Sub-Main Deck
TOS EL (+) 16,600 mm