Electric Motors
Electric Motors
Electric Motors
U.S. Patent 381968: Mode and plan of operating electric motors by progressive shifting; Field
Magnet; Armature; Electrical conversion; Economical; Transmission of energy; Simple
construction; Easier construction; Rotating magnetic field principles.
Nikola Tesla
circa 1890.
10 July 1856
Born Smiljan, Austrian Empirea
(Croatian Military Frontier)
Austria-Hungarya
Residence France
United States of America
Austro-Hungariana (1856–1891)
Citizenship
American (1891–1943)
Nationality Serbian
Signature
Notes
a
Austrian Empire (1804–1867) reorganized and
renamed into the Austro-Hungarian Monarchy
(1867–1918) in 1867
Nikola Tesla's AC dynamo used to generate AC which is used to transport electricity across great
distances. It is contained in U.S. Patent 390,721.
AC motor
An AC motor is an electric motor that is driven by an alternating current. It consists of two basic parts, an
outside stationary stator (there are examples such as some of the Papst motors that have the stator on the
inside and the rotor on the outside to increase the inertia and cooling, they were common on high quality
tape and film machines where speed stability is important) having coils supplied with alternating current to
produce a rotating magnetic field, and an inside rotor attached to the output shaft that is given a torque by
the rotating field.
There are two types of AC motors, depending on the type of rotor used (not including eddy current motors
also AC/DC mechanically commutated machines which are speed dependant on voltage and winding
connection). The first is the synchronous motor, which rotates exactly at the supply frequency or a
submultiple of the supply frequency. The magnetic field on the rotor is either generated by current delivered
through slip rings or by a permanent magnet.
The second type is the induction motor, which runs slightly slower than the supply frequency. The magnetic
field on the rotor of this motor is created by an induced current.
History
In 1882 Nikola Tesla identified the rotating magnetic induction field principle[1][2] used in alternators and
pioneered the use of this rotating and inducting electromagnetic field force to generate torque in rotating
machines. He exploited this principle in the design of a poly-phase induction motor in 1883. In 1885, Galileo
Ferraris independently researched the concept. In 1888, Ferraris published his research in a paper to the
Royal Academy of Sciences in Turin.
Introduction of Tesla's motor in 1888 initiated what is sometimes referred to as the Second Industrial
Revolution, making possible both the efficient generation and long distance distribution of electrical energy
using the alternating current transmission system, also of Tesla's invention (1888).[3] Before widespread use
of Tesla's principle of poly-phase induction for rotating machines, all motors operated by continually passing
a conductor through a stationary magnetic field (as in homopolar motor).
Initially Tesla suggested that the commutators from a machine could be removed and the device could
operate on a rotary field of electromagnetic force. Professor Poeschel, his teacher, stated that would be akin
to building a perpetual motion machine. This was because Tesla's teacher had only understood one half of
Tesla's ideas. Professor Poeschel had realized that the induced rotating magnetic field would start the rotor
of the motor spinning, but he did not see that the counter electromotive force generated would gradually
bring the machine to a stop.[4] Tesla would later obtain U.S. Patent 0,416,194, Electric Motor (December
1889), which resembles the motor seen in many of Tesla's photos. This classic alternating current electro-
magnetic motor was an induction motor.
Michail Osipovich Dolivo-Dobrovolsky later invented a three-phase "cage-rotor" in 1890. This type of motor
is now used for the vast majority of commercial applications.
Squirrel-cage rotors
Most common AC motors use the squirrel cage rotor, which will be found in virtually all domestic and light
industrial alternating current motors. The squirrel cage refers to the rotating exercise cage for pet animals.
The motor takes its name from the shape of its rotor "windings"- a ring at either end of the rotor, with bars
connecting the rings use cast copper to reduce the resistance in the rotor.running the length of the rotor. It
is typically cast aluminum or copper poured between the iron laminates of the rotor, and usually only the
end rings will be visible. The vast majority of the rotor currents will flow through the bars rather than the
higher-resistance and usually varnished laminates. Very low voltages at very high currents are typical in the
bars and end rings; high efficiency motors will often
In operation, the squirrel cage motor may be viewed as a transformer with a rotating secondary. When the
rotor is not rotating in sync with the magnetic field, large rotor currents are induced; the large rotor currents
magnetize the rotor and interact with the stator's magnetic fields to bring the rotor almost into
synchronization with the stator's field. An unloaded squirrel cage motor at rated no-load speed will consume
electrical power only to maintain rotor speed against friction and resistance losses. As the mechanical load
increases, so will the electrical load - the electrical load is inherently related to the mechanical load. This is
similar to a transformer, where the primary's electrical load is related to the secondary's electrical load.
This is why a squirrel cage blower motor may cause household lights to dim upon starting, but doesn't dim
the lights on startup when its fan belt (and therefore mechanical load) is removed. Furthermore, a stalled
squirrel cage motor (overloaded or with a jammed shaft) will consume current limited only by circuit
resistance as it attempts to start. Unless something else limits the current (or cuts it off completely)
overheating and destruction of the winding insulation is the likely outcome.
To prevent the currents induced in the squirrel cage from superimposing itself back onto the supply, the
squirrel cage is generally constructed with a prime number of bars, or at least a small multiple of a prime
number (rarely more than 2). There is an optimum number of bars in any design, and increasing the
number of bars beyond that point merely serves to increase the losses of the motor particularly when
starting.
Virtually every washing machine, dishwasher, standalone fan, record player, etc. uses some variant of a
squirrel cage motor.
Squirrel-cage rotor
A squirrel cage rotor is the rotating part used in the most common form of AC induction motor. An electric
motor with a squirrel cage rotor is termed a squirrel cage motor.
Structure
In overall shape, it is a cylinder mounted on a shaft. Internally it contains longitudinal conductive bars
(usually made of aluminum or copper) set into grooves and connected together at both ends by shorting
rings forming a cage-like shape. The name is derived from the similarity between this rings-and-bars
winding and a squirrel cage (or, as it is commonly known, a hamster wheel).
The core of the rotor is built with stacks of electrical steel laminations. Figure 3 shows three of many
laminations used.
Theory
The field windings in the stator of an induction motor set up a rotating magnetic field around the rotor. The
relative motion between this field and the rotation of the rotor induces electric current in the conductive
bars. In turn these currents lengthwise in the conductors react with the magnetic field of the motor to
produce force acting at a tangent orthogonal to the rotor, resulting in torque to turn the shaft. In effect the
rotor is carried around with the magnetic field but at a slightly slower rate of rotation. The difference in
speed is called slip and increases with load.
The conductors are often skewed slightly along the length of the rotor to reduce noise and smooth out
torque fluctuations that might result at some speeds due to interactions with the pole pieces of the stator.
The number of bars on the squirrel cage determines to what extent the induced currents are fed back to the
stator coils and hence the current through them. The constructions that offer the least feedback employ
prime numbers of bars.
The iron core serves to carry the magnetic field across the motor. In structure and material it is designed to
minimize losses. The thin laminations, separated by varnish insulation, reduce stray circulating currents that
would result in eddy current loss. The material is a low carbon but high silicon iron with several times the
resistivity of pure iron, further reducing eddy-current loss. The low carbon content makes it a magnetically
soft material with low hysteresis loss.
The same basic design is used for both single-phase and three-phase motors over a wide range of sizes.
Rotors for three-phase will have variations in the depth and shape of bars to suit the design classification.
Practical Demonstration
To demonstrate how the cage rotor works, the stator of a single-phase motor and a copper pipe (as rotor)
may be used. If adequate ac power is applied to the stator, an alternating magnetic field revolves around
the stator. If the copper pipe is inserted inside the stator, there will be an induced current in the pipe, and
this current produces another magnetic field. The interaction of the stator revolving field and rotor induced
field produce a torque and thus rotation.
Use in synchronous motors
Synchronous motors must use other types of rotors although they may employ a squirrel cage winding to
allow them to reach near-synchronous speed while starting. Once operating at synchronous speed, the
magnetic field is rotating at the same speed as the rotor, so no current will be induced into the squirrel cage
windings and they will have no further effect on the operation of the synchronous motor.
Induction generators
Three phase squirrel cage induction motors can also be used as generators. For this to work the motor must
either be connected to a grid supply or an arrangement of capacitors. If the motor is run as a self exciting
induction generator (SEIG) the capacitors can either be connected in a delta or c2c arrangement. The c2c
method is for producing a single phase output and the delta method is for a three phase output. For the
motor to work as a generator instead of a motor the rotor must be spun just faster than its nameplate
speed, this will cause the motor to generate power after building up its residual magnetism.
Calecon Effect
If the rotor of a squirrel runs at the true synchronous speed, the flux in the rotor at any given place on the
rotor would not change, and no current would be created in the squirrel cage. For this reason, ordinary
squirrel-cage motors run at some tens of rpm slower than synchronous speed, even at no load. Because the
rotating field (or equivalent pulsating field) actually or effectively rotates faster than the rotor, it could be
said to slip past the surface of the rotor. The difference between synchronous speed and actual speed is
called slip, and loading the motor increases the amount of slip as the motor slows down slightly.
A typical two-phase AC servo-motor has a squirrel cage rotor and a field consisting of two windings:
An AC servo amplifier, a linear power amplifier, feeds the control winding. The electrical resistance of the
rotor is made high intentionally so that the speed/torque curve is fairly linear. Two-phase servo motors are
inherently high-speed, low-torque devices, heavily geared down to drive the load.
Three-phase motors produce a rotating magnetic field. However, when only single-phase power is available,
the rotating magnetic field must be produced using other means. Several methods are commonly used:
Shaded-pole motor
A common single-phase motor is the shaded-pole motor and is used in devices requiring low starting torque,
such as electric fans or the drain pump of washing machines and dishwashers or in other small household
appliances. In this motor, small single-turn copper "shading coils" create the moving magnetic field. Part of
each pole is encircled by a copper coil or strap; the induced current in the strap opposes the change of flux
through the coil. This causes a time lag in the flux passing through the shading coil, so that the maximum
field intensity moves across the pole face on each cycle. This produces a low level rotating magnetic field
which is large enough to turn both the rotor and its attached load. As the rotor picks up speed the torque
builds up to its full level as the principal magnetic field is rotating relative to the rotating rotor.
A reversible shaded-pole motor was made by Barber-Colman several decades ago. It had a single field
coil, and two principal poles, each split halfway to create two pairs of poles. Each of these four "half-poles"
carried a coil, and the coils of diagonally-opposite half-poles were connected to a pair of terminals. One
terminal of each pair was common, so only three terminals were needed in all.
The motor would not start with the terminals open; connecting the common to one other made the motor
run one way, and connecting common to the other made it run the other way. These motors were used in
industrial and scientific devices.
Applying AC to the coil created a field that progressed in the gap between the poles. The plane of the stator
core was approximately tangential to an imaginary circle on the disc, so the travelling magnetic field
dragged the disc and made it rotate.
The stator was mounted on a pivot so it could be positioned for the desired speed and then clamped in
position. Keeping in mind that the effective speed of the travelling magnetic field in the gap was constant,
placing the poles nearer to the centre of the disc made it run relatively faster, and toward the edge, slower.
It is possible that these motors are still in use in some older installations.
Another common single-phase AC motor is the split-phase induction motor,[5] commonly used in major
appliances such as washing machines and clothes dryers. Compared to the shaded pole motor, these motors
can generally provide much greater starting torque by using a special startup winding in conjunction with a
centrifugal switch.
In the split-phase motor, the startup winding is designed with a higher resistance than the running winding.
This creates an LR circuit which slightly shifts the phase of the current in the startup winding. When the
motor is starting, the startup winding is connected to the power source via a set of spring-loaded contacts
pressed upon by the stationary centrifugal switch. The starting winding is wound with fewer turns of smaller
wire than the main winding, so it has a lower inductance (L) and higher resistance (R). The lower L/R ratio
creates a small phase shift, not more than about 30 degrees, between the flux due to the main winding and
the flux of the starting winding. The starting direction of rotation may be reversed simply by exchanging the
connections of the startup winding relative to the running winding.
The phase of the magnetic field in this startup winding is shifted from the phase of the mains power,
allowing the creation of a moving magnetic field which starts the motor. Once the motor reaches near
design operating speed, the centrifugal switch activates, opening the contacts and disconnecting the startup
winding from the power source. The motor then operates solely on the running winding. The starting
winding must be disconnected since it would increase the losses in the motor.
A capacitor start motor is a split-phase induction motor with a starting capacitor inserted in series with the
startup winding, creating an LC circuit which is capable of a much greater phase shift (and so, a much
greater starting torque). The capacitor naturally adds expense to such motors.
A resistance start motor is a split-phase induction motor with a starter inserted in series with the startup
winding, creating capacitance. This added starter provides assistance in the starting and initial direction of
rotation.
Another variation is the permanent-split capacitor (PSC) motor (also known as a capacitor start and run
motor).[6] This motor operates similarly to the capacitor-start motor described above, but there is no
centrifugal starting switch,[6] and what correspond to the start windings (second windings) are permanently
connected to the power source (through a capacitor), along with the run windings.[6] PSC motors are
frequently used in air handlers, blowers, and fans (including ceiling fans) and other cases where a variable
speed is desired.
A capacitor ranging from 3 to 25 microfarads is connected in series with the "start" windings and remains in
the circuit during the run cycle.[6] The "start" windings and run windings are identical in this motor,[6] and
reverse motion can be achieved by reversing the wiring of the 2 windings,[6] with the capacitor connected to
the other windings as "start" windings. By changing taps on the running winding but keeping the load
constant, the motor can be made to run at different speeds. Also, provided all 6 winding connections are
available separately, a 3 phase motor can be converted to a capacitor start and run motor by commoning
two of the windings and connecting the third via a capacitor to act as a start winding.
Wound rotors
An alternate design, called the wound rotor, is used when variable speed is required. In this case, the rotor
has the same number of poles as the stator and the windings are made of wire, connected to slip rings on
the shaft. Carbon brushes connect the slip rings to an external controller such as a variable resistor that
allows changing the motor's slip rate. In certain high-power variable speed wound-rotor drives, the slip-
frequency energy is captured, rectified and returned to the power supply through an inverter. With
bidirectionally controlled power, the wound-rotor becomes an active participant in the energy conversion
process with the wound-rotor doubly-fed configuration showing twice the power density.
Compared to squirrel cage rotors and without considering brushless wound-rotor doubly-fed technology,
wound rotor motors are expensive and require maintenance of the slip rings and brushes, but they were the
standard form for variable speed control before the advent of compact power electronic devices.
Transistorized inverters with variable-frequency drive can now be used for speed control, and wound rotor
motors are becoming less common.
Several methods of starting a polyphase motor are used. Where the large inrush current and high starting
torque can be permitted, the motor can be started across the line, by applying full line voltage to the
terminals (direct-on-line, DOL). Where it is necessary to limit the starting inrush current (where the motor is
large compared with the short-circuit capacity of the supply), reduced voltage starting using either series
inductors, an autotransformer, thyristors, or other devices are used. A technique sometimes used is (star-
delta, YΔ) starting, where the motor coils are initially connected in star for acceleration of the load, then
switched to delta when the load is up to speed. This technique is more common in Europe than in North
America. Transistorized drives can directly vary the applied voltage as required by the starting
characteristics of the motor and load.
This type of motor is becoming more common in traction applications such as locomotives, where it is known
as the asynchronous traction motor.
The speed of the AC motor is determined primarily by the frequency of the AC supply and the number of
poles in the stator winding, according to the relation:
Ns = 120F / p
where
F = AC power frequency
Actual RPM for an induction motor will be less than this calculated synchronous speed by an amount known
as slip, that increases with the torque produced. With no load, the speed will be very close to synchronous.
When loaded, standard motors have between 2-3% slip, special motors may have up to 7% slip, and a class
of motors known as torque motors are rated to operate at 100% slip (0 RPM/full stall).
S = (Ns − Nr) / Ns
where
S = Normalised Slip, 0 to 1.
As an example, a typical four-pole motor running on 60 Hz might have a nameplate rating of 1725 RPM at
full load, while its calculated speed is 1800 RPM.
The speed in this type of motor has traditionally been altered by having additional sets of coils or poles in
the motor that can be switched on and off to change the speed of magnetic field rotation. However,
developments in power electronics mean that the frequency of the power supply can also now be varied to
provide a smoother control of the motor speed.
Nowadays, synchronous motors are frequently driven by transistorized variable-frequency drives. This
greatly eases the problem of starting the massive rotor of a large synchronous motor. They may also be
started as induction motors using a squirrel-cage winding that shares the common rotor: once the motor
reaches synchronous speed, no current is induced in the squirrel-cage winding so it has little effect on the
synchronous operation of the motor, aside from stabilizing the motor speed on load changes.
Synchronous motors are occasionally used as traction motors; the TGV may be the best-known example of
such use.
One use for this type of motor is its use in a power factor correction scheme. They are referred to as
synchronous condensers. This exploits a feature of the machine where it consumes power at a leading power
factor when its rotor is over excited. It thus appears to the supply to be a capacitor, and could thus be used
to correct the lagging power factor that is usually presented to the electric supply by inductive loads. The
excitation is adjusted until a near unity power factor is obtained (often automatically). Machines used for
this purpose are easily identified as they have no shaft extensions. Synchronous motors are valued in any
case because their power factor is much better than that of induction motors, making them preferred for
very high power applications.
Some of the largest AC motors are pumped-storage hydroelectricity generators that are operated as
synchronous motors to pump water to a reservoir at a higher elevation for later use to generate electricity
using the same machinery. Six 350-megawatt generators are installed in the Bath County Pumped Storage
Station in Virginia, USA. When pumping, each unit can produce 563,400 horsepower (420 megawatts).[7]
AC motors can also have brushes. The universal motor is widely used in small home appliances and power
tools.
Repulsion motor
Repulsion motors are wound-rotor single-phase AC motors that are similar to universal motors. In a
repulsion motor, the armature brushes are shorted together rather than connected in series with the field.
By transformer action ,the stator induces currents in the rotor, which create torque by repulsion instead of
attraction as in other motors. Several types of repulsion motors have been manufactured, but the repulsion-
start induction-run (RS-IR) motor has been used most frequently. The RS-IR motor has a centrifugal switch
that shorts all segments of the commutator so that the motor operates as an induction motor once it has
been accelerated to full speed. Some of these motors also lift the brushes out of contact with the
commutator once the commutator is shorted. RS-IR motors have been used to provide high starting torque
per ampere under conditions of cold operating temperatures and poor source voltage regulation. Few
repulsion motors of any type are sold as of 2005.
Small single-phase AC motors can also be designed with magnetized rotors (or several variations on that
idea; see "Hysteresis synchronous motors" below).
If a conventional squirrel-cage rotor has flats ground on it to create salient poles and increase reluctance, it
will start conventionally, but will run synchronously, although it can provide only a modest torque at
synchronous speed. This is known as a reluctance motor.
Because inertia makes it difficult to instantly accelerate the rotor from stopped to synchronous speed, these
motors normally require some sort of special feature to get started. Some include a squirrel-cage structure
to bring the rotor close to synchronous speed. Various other designs use a small induction motor (which
may share the same field coils and rotor as the synchronous motor) or a very light rotor with a one-way
mechanism (to ensure that the rotor starts in the "forward" direction). In the latter instance, applying AC
power creates chaotic (or seemingly chaotic) jumping movement back and forth; such a motor will always
start, but lacking the anti-reversal mechanism, the direction it runs is unpredictable. The Hammond organ
tone generator used a non-self-starting synchronous motor (until comparatively recently), and had an
auxiliary conventional shaded-pole starting motor. A spring-loaded auxiliary manual starting switch
connected power to this second motor for a few seconds.
These motors are relatively costly, and are used where exact speed (assuming an exact-frequency AC
source) as well as rotation with a very small amount of fast variations in speed (called 'flutter" in audio
recordings) is essential. Applications included tape recorder capstan drives (the motor shaft could be the
capstan). Their distinguishing feature is their rotor, which is a smooth cylinder of a magnetic alloy that stays
magnetized, but can be demagnetized fairly easily as well as re-magnetized with poles in a new location.
Hysteresis refers to how the magnetic flux in the metal lags behind the external magnetizing force; for
instance, to demagnetize such a material, one could apply a magnetizing field of opposite polarity to that
which originally magnetized the material.
These motors have a stator like those of capacitor-run squirrel-cage induction motors. On startup, when slip
decreases sufficiently, the rotor becomes magnetized by the stator's field, and the poles stay in place. The
motor then runs at synchronous speed as if the rotor were a permanent magnet. When stopped and re-
started, the poles are likely to form at different locations.
For a given design, torque at synchronous speed is only relatively modest, and the motor can run at below
synchronous speed.
Such motors have an external rotor with a cup-shaped housing and a radially magnetized permanent
magnet connected in the cup-shaped housing. An interior stator is positioned in the cup-shaped housing.
The interior stator has a laminated core having grooves. Windings are provided within the grooves. The
windings have first end turns proximal to a bottom of the cup-shaped housing and second end turns
positioned distal to the bottom. The first and second end turns electrically connect the windings to one
another. The permanent magnet has an end face rom the bottom of the cup-shaped housing. At least one
galvano-magnetic rotor position sensor is arranged opposite the end face of the permanent magnet so as to
be located within a magnetic leakage of the permanent magnet and within a magnetic leakage of the interior
stator. The at least one rotor position sensor is designed to control current within at least a portion of the
windings. A magnetic leakage flux concentrator is arranged at the interior stator at the second end turns at
a side of the second end turns facing away from the laminated core and positioned at least within an angular
area of the interior stator in which the at (?-someone got distracted)
ECM motors are increasingly being found in forced-air furnaces and HVAC systems to save on electricity
costs as modern HVAC systems are running their fans for longer periods of time (duty cycle).[8] The cost
effectiveness of using ECM motors in HVAC systems is questionable, given that the repair (replacement)
costs are likely to equal or exceed the savings realized by using such a motor.
Watthour-meter motors
These are essentially two-phase induction motors with permanent magnets that retard rotor speed, so their
speed is quite accurately proportional to wattage of the power passing through the meter. The rotor is an
aluminium-alloy disc, and currents induced into it react with the field from the stator.
The stator is composed of three coils that are arranged facing the disc surface, with the magnetic circuit
completed by a C-shaped core of permeable iron. One phase of the motor is produced by a coil with many
turns located above the disc surface. This upper coil has a relatively high inductance, and is connected in
parallel with the load. The magnetic field produced in this coil lags the applied (line/mains) voltage by
almost 90 degrees. The other phase of the motor is produced by a pair of coils with very few turns of heavy-
gauge wire, and hence quite-low inductance. These coils, located on the underside of the disc surface, are
wired in series with the load, and produce magnetic fields in-phase with the load current.
Because the two lower coils are wound anti-parallel, and are each located equidistant from the upper coil, an
azimuthally traveling magnetic flux is created across the disc surface. This traveling flux exerts an average
torque on the disc proportional to the product of the power factor; RMS current, and voltage. It follows that
the rotation of the magnetically-braked disc is in effect an analogue integration the real RMS power
delivered to the load. The mechanical dial on the meter then simply reads off a numerical value proportional
to the total number of revolutions of the disc, and thus the total energy delivered to the load.
Representative are low-torque synchronous motors with a multi-pole hollow cylindrical magnet (internal
poles) surrounding the stator structure. An aluminum cup supports the magnet. The stator has one coil,
coaxial with the shaft. At each end of the coil are a pair of circular plates with rectangular teeth on their
edges, formed so they are parallel with the shaft. They are the stator poles. One of the pair of discs
distributes the coil's flux directly, while the other receives flux that has passed through a common shading
coil. The poles are rather narrow, and between the poles leading from one end of the coil are an identical set
leading from the other end. In all, this creates a repeating sequence of four poles, unshaded alternating with
shaded, that creates a circumferential traveling field to which the rotor's magnetic poles rapidly synchronize.
Some stepping motors have a similar structure.
When considering starting criteria, we must determine how often the motor will be started, once a week,
once a day, once an hour. The reason we are concerned with the frequency of starting is the high starting
current.
Acceleration Restrictions
Some applications require a motor to accelerate the driven load to normal operating speed within in a
certain time frame. The longer a motor takes to accelerate, the higher the temperature rise in the motor.
The larger the load, the longer is the acceleration time. A motor's ability to accelerate a driven load
influences both the safety and performance factors of an operation.
Motors operate satisfactorily on voltage that is within 10 percent, or frequency within 5 percent, of the
optimal value listed on the motor nameplate. There is a risk of motor damage if the combined total voltage
and frequency variation of a power supply exceeds 10 percent.
Phase
Motors operate on either single or three phase electrical
power. Single phase motors may operate on one phase
of a three phase power supply with a compatible
voltage rating. Many power suppliers do not allow large
single phase motors to be connected to their lines. This
is because a single phase motor larger than 10
horsepower started on a three phase source often
causes voltage flicker problems.
This is a diagram that may be helpful in understanding how single and three phase power commonly appear.
If the standard motor does not fit, determine whether it is most economical to change the driven machine,
use a different standard motor, or adapt the standard motor by using a mechanical modification or
accessory.
Ambient Temperature
NEMA rates most motors for exposure to ambient temperatures ranging from 32 to 104 degrees F (0 to 40
degrees C). If the motor has water cooling capabilities, NEMA ratings range from 50 to 104 degrees F (10 to
40 degrees C). Standard NEMA maximum ambient temperature is 104 degrees F.
Altitude
NEMA bases temperature rise ratings on operation altitudes of 3,300 feet (1,000 meters) or less. NEMA
considers any altitude up to 3,300 feet equivalent to sea level. NEMA also assumes a maximum ambient
temperature of 104 degrees F (40 degrees C) within these parameters.
When a motor operates at high altitude, de-rating is necessary since lower air density does not cool motors
as well as high density air. Motors with Class B or F insulation systems and temperature rise in accordance
with NEMA operate satisfactorily at altitudes above 3,300 feet; as long as ambient temperature remains
lower than 104 degrees F (40 degrees C).
For example, electric motors that run continuously in fans and blowers for hours or days may be selected on
the basis of continuous load. But electric motors located in devices like automatically controlled compressors
and pumps start a number of times per hour. And electric motors in some machine tools start and stop
many times per minute.
Duty cycle is a fixed repetitive load pattern over a given period of time which is expressed as the ratio of on-
time to cycle period. When operating cycle is such that electric motors operate at idle or a reduced load for
more than 25% of the time, duty cycle becomes a factor in sizing electric motors. Also, energy required to
start electric motors (that is, accelerating the inertia of the electric motor as well as the driven load) is much
higher than for steady-state operation, so frequent starting could overheat the electric motor.
For most electric motors (except squirrel-cage electric motors during acceleration and plugging) current is
almost directly proportional to developed torque. At constant speed, torque is proportional to horsepower.
For accelerating loads and overloads on electric motors that have considerable droop, equivalent horsepower
is used as the load factor. The next step in sizing the electric motor is to examine the electric motor's
performance curves to see if the electric motor has enough starting torque to overcome machine static
friction, to accelerate the load to full running speed, and to handle maximum overload.
Electric Motors - Service factors:
A change in NEMA standards for electric motor service factors and temperature rise has been brought about
because of better insulation used on electric motors. For instance, a 1.15 service factor -- once standard for
all open electric motors -- is no longer standard for electric motors above 200 hp.
Increases in electric motor temperature are measured by the resistance method in the temperature rise
table. Electric motors feature a nameplate temperature rise, which is always expressed for the maximum
allowable load. That is, if the electric motor has a service factor greater than unity, the nameplate
temperature rise is expressed for the overload. Two Class-B insulated electric motors having 1.15 and 1.25
service factors will, therefore, each be rated for a 90°C rise. But the second electric motor will have to be
larger than the first in order to dissipate the additional heat it generates at 125% load.
Electric motors feature a service factor, which indicates how much over the nameplate rating any given
electric motor can be driven without overheating. NEMA Standard MGI-143 defines service factor of an ac
motor as "...a multiplier which, when applied to the rated horsepower, indicates a permissible horsepower
loading which may be carried under the conditions specified for the service factor..." In other words,
multiplying the electric motor's nameplate horsepower by the service factor tells how much electric motors
can be overloaded without overheating. Generally, electric motor service factors:
Electric motor's feature an efficiency level, which also depends on actual electric motor load versus rated
load, being greatest near rated load and falling off rapidly for under and overload conditions.
A motor must produce enough torque to accelerate from a standstill to operating speed, and supply
enough power for all possible demands without exceeding its design limits. Selecting the right motor for
the application is not always a simple task.
In this section we examine the characteristics of driving the load, and see how important each part is in
properly specifying a motor.
Pulse-width modulation
An example of PWM in an AC motor drive: the phase-to-phase voltage (blue) is modulated as a series of
pulses that results in a sine-like flux density waveform (red) in the magnetic circuit of the motor. The
smoothness of the resultant waveform can be controlled by the width and number of modulated
impulses (per given cycle)
Pulse-width modulation (PWM) is a commonly used technique for controlling power to an electrical device,
made practical by modern electronic power switches. The average value of voltage (and current) fed to the
load is controlled by turning the switch between supply and load on and off at a fast pace. The longer the
switch is on compared to the off periods, the higher the power supplied to the load is.
The PWM switching frequency has to be much faster than what would affect the load, which is to say the
device that uses the power. Typically switchings have to be done several times a minute in an electric stove,
120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or
hundreds of kHz in audio amplifiers and computer power supplies.
The term duty cycle describes the proportion of on time to the regular interval or period of time; a low
duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed
in percent, 100% being fully on.
The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off
there is practically no current, and when it is on, there is almost no voltage drop across the switch. Power
loss, being the product of voltage and current, is thus in both cases close to zero. PWM works also well with
digital controls, which, because of their on/off nature, can easily set the needed duty cycle.
PWM has also been used in certain communication systems where its duty cycle has been used to convey
information over a communications channel.
History
In the past, when only partial power was needed (such as for a sewing machine motor), a rheostat (located
in the sewing machine's foot pedal) connected in series with the motor adjusted the amount of current
flowing through the motor, but also wasted power as heat in the resistor element. It was an inefficient
scheme, but tolerable because the total power was low. This was one of several methods of controlling
power. There were others—some still in use—such as variable autotransformers, including the trademarked
Autrastat for theatrical lighting; and the Variac, for general AC power adjustment. These were quite
efficient, but also relatively costly.
For about a century, some variable-speed electric motors have had decent efficiency, but they were
somewhat more complex than constant-speed motors, and sometimes required bulky external electrical
apparatus, such as a bank of variable power resistors or rotating converter such as Ward Leonard drive .
However, in addition to motor drives for fans, pumps and robotic servos, there was a great need for
compact and low cost means for applying adjustable power for many devices, such as electric stoves and
lamp dimmers.
One of early applications of PWM was in the Sinclair X10, a 10 W audio amplifier available in kit form in the
1960s. At around the same time PWM started to be used in AC motor control [1]
[edit] Principle
Pulse-width modulation uses a rectangular pulse wave whose pulse width is modulated resulting in the
variation of the average value of the waveform. If we consider a pulse waveform f(t) with a low value
ymin, a high value ymax and a duty cycle D (see figure 1), the average value of the waveform is given
by:
As f(t) is a pulse wave, its value is ymax for and ymin for .
The above expression then becomes:
This latter expression can be fairly simplified in many cases where ymin = 0 as . From
this, it is obvious that the average value of the signal ( ) is directly dependent on the duty cycle D.
Fig. 2: A simple method to generate the PWM pulse train corresponding to a given signal is the
intersective PWM: the signal (here the green sinewave) is compared with a sawtooth waveform (blue).
When the latter is less than the former, the PWM signal (magenta) is in high state (1). Otherwise it is in
the low state (0).
The simplest way to generate a PWM signal is the intersective method, which requires only a sawtooth or a
triangle waveform (easily generated using a simple oscillator) and a comparator. When the value of the
reference signal (the green sine wave in figure 2) is more than the modulation waveform (blue), the PWM
signal (magenta) is in the high state, otherwise it is in the low state.
Delta
In the use of delta modulation for PWM control, the output signal is integrated, and the result is compared
with limits, which correspond to a reference signal offset by a constant. Every time the integral of the output
signal reaches one of the limits, the PWM signal changes state.
Fig. 3 : Principle of the delta PWM. The output signal (blue) is compared with the limits (green). These
limits correspond to the reference signal (red), offset by a given value. Every time the output signal
reaches one of the limits, the PWM signal changes state.
Delta-sigma
In delta-sigma modulation as a PWM control method, the output signal is subtracted from a reference signal
to form an error signal. This error is integrated, and when the integral of the error exceeds the limits, the
output changes state.
Fig. 4 : Principle of the sigma-delta PWM. The top green waveform is the reference signal, on which the
output signal (PWM, in the middle plot) is subtracted to form the error signal (blue, in top plot). This
error is integrated (bottom plot), and when the integral of the error exceeds the limits (red lines), the
output changes state.
Space vector modulation is a PWM control algorithm for multi-phase AC generation, in which the reference
signal is sampled regularly; after each sample, non-zero active switching vectors adjacent to the reference
vector and one or more of the zero switching vectors are selected for the appropriate fraction of the
sampling period in order to synthesize the reference signal as the average of the used vectors.
Direct torque control is a method used to control AC motors. It is closely related with the delta modulation
(see above). Motor torque and magnetic flux are estimated and these are controlled to stay within their
hysteresis bands by turning on new combination of the device's semiconductor switches each time either of
the signal tries to deviate out of the band.
Time proportioning
Many digital circuits can generate PWM signals (e.g. many microcontrollers have PWM outputs). They
normally use a counter that increments periodically (it is connected directly or indirectly to the clock of the
circuit) and is reset at the end of every period of the PWM. When the counter value is more than the
reference value, the PWM output changes state from high to low (or low to high).[2] This technique is
referred to as time proportioning, particularly as time-proportioning control[3] – which proportion of a
fixed cycle time is spent in the high state.
The incremented and periodically reset counter is the discrete version of the intersecting method's sawtooth.
The analog comparator of the intersecting method becomes a simple integer comparison between the
current counter value and the digital (possibly digitized) reference value. The duty cycle can only be varied
in discrete steps, as a function of the counter resolution. However, a high-resolution counter can provide
quite satisfactory performance.
Types
Fig. 5 : Three types of PWM signals (blue): leading edge modulation (top), trailing edge modulation
(middle) and centered pulses (both edges are modulated, bottom). The green lines are the sawtooth
waveform (first and second cases) and a triangle waveform (third case) used to generate the PWM
waveforms using the intersective method.
1. The pulse center may be fixed in the center of the time window and both edges of the pulse
moved to compress or expand the width.
2. The lead edge can be held at the lead edge of the window and the tail edge modulated.
3. The tail edge can be fixed and the lead edge modulated.
4. The pulse repetition frequency can be varied by the signal, and the pulse width can be constant.
However, this method has a more-restricted range of average output than the other three.
Spectrum
The resulting spectra (of the three cases) are similar, and each contains a dc component, a base sideband
containing the modulating signal and phase modulated carriers at each harmonic of the frequency of the
pulse. The amplitudes of the harmonic groups are restricted by a sinx / x envelope (sinc function) and
extend to infinity.
On the contrary, the delta modulation is a random process that produces continuous spectrum without
distinct harmonics.
Applications
Telecommunications
In telecommunications, the widths of the pulses correspond to specific data values encoded at one end and
decoded at the other.
Pulses of various lengths (the information itself) will be sent at regular intervals (the carrier frequency of the
modulation).
_ _ _ _ _ _ _ _
| | | | | | | | | | | | | | | |
Clock | | | | | | | | | | | | | | | |
__| |____| |____| |____| |____| |____| |____| |____| |____
_ __ ____ ____ _
PWM Signal | | | | | | | | | |
| | | | | | | | | |
_________| |____| |___| |________| |_| |___________
Data 0 1 2 4 0 4 1 0
The inclusion of a clock signal is not necessary, as the leading edge of the data signal can be used as the
clock if a small offset is added to the data value in order to avoid a data value with a zero length pulse.
Data 0 1 2 4 0 4 1 0
Power delivery
PWM can be used to adjust the total amount of power delivered to a load without losses normally incurred
when a power transfer is limited by resistive means. The drawback are the pulsations defined by the duty
cycle, switching frequency and properties of the load. With a sufficiently high switching frequency and, when
necessary, using additional passive electronic filters the pulse train can be smoothed and average analog
waveform recovered.
High frequency PWM power control systems are easily realisable with semiconductor switches. As has been
already stated above almost no power is dissipated by the switch in either on or off state. However, during
the transitions between on and off states both voltage and current are non-zero and thus considerable
power is dissipated in the switches. Luckily, the change of state between fully on and fully off is quite rapid
(typically less than 100 nanoseconds) relative to typical on or off times, and so the average power
dissipation is quite low compared to the power being delivered even when high switching frequencies are
used.
Modern semiconductor switches such as MOSFETs or Insulated-gate bipolar transistors (IGBTs) are quite
ideal components. Thus high efficiency controllers can be built. Typically frequency converters used to
control AC motors have efficiency that is better than 98 %. Switching power supplies have lower efficiency
due to low output voltage levels (often even less than 2 V for microprocessors are needed) but still more
than 70-80 % efficiency can be achieved.
Variable-speed fan controllers for computers usually use PWM, as it is far more efficient when compared to a
potentiometer or rheostat. (Neither of the latter is practical to operate electronically; they would require a
small drive motor.)
Light dimmers for home use employ a specific type of PWM control. Home use light dimmers typically
include electronic circuitry which suppresses current flow during defined portions of each cycle of the AC line
voltage. Adjusting the brightness of light emitted by a light source is then merely a matter of setting at what
voltage (or phase) in the AC halfcycle the dimmer begins to provide electrical current to the light source
(e.g. by using an electronic switch such as a triac). In this case the PWM duty cycle is the ratio of the
conduction time to the duration of the half AC cycle defined by the frequency of the AC line voltage (50 Hz
or 60 Hz depending on the country).
These rather simple types of dimmers can be effectively used with inert (or relatively slow reacting) light
sources such as incandescent lamps, for example, for which the additional modulation in supplied electrical
energy which is caused by the dimmer causes only negligible additional fluctuations in the emitted light.
Some other types of light sources such as light-emitting diodes (LEDs), however, turn on and off extremely
rapidly and would perceivably flicker if supplied with low frequency drive voltages. Perceivable flicker effects
from such rapid response light sources can be reduced by increasing the PWM frequency. If the light
fluctuations are sufficiently rapid, the human visual system can no longer resolve them and the eye
perceives the time average intensity without flicker (see flicker fusion threshold).
In electric cookers, continuously-variable power is applied to the heating elements such as the hob or the
grill using a device known as a Simmerstat. This consists of a thermal oscillator running at approximately
two cycles per minute and the mechanism varies the duty cycle according to the knob setting. The thermal
time constant of the heating elements is several minutes, so that the temperature fluctuations are too small
to matter in practice.
Voltage regulation
PWM is also used in efficient voltage regulators. By switching voltage to the load with the appropriate duty
cycle, the output will approximate a voltage at the desired level. The switching noise is usually filtered with
an inductor and a capacitor.
One method measures the output voltage. When it is lower than the desired voltage, it turns on the switch.
When the output voltage is above the desired voltage, it turns off the switch.
Audio effects and amplification
PWM is sometimes used in sound (music) synthesis, in particular subtractive synthesis, as it gives a sound
effect similar to chorus or slightly detuned oscillators played together. (In fact, PWM is equivalent to the
difference of two sawtooth waves. [1]) The ratio between the high and low level is typically modulated with
a low frequency oscillator, or LFO. In addition, varying the duty cycle of a pulse waveform in a subtractive-
synthesis instrument creates useful timbral variations. Some synthesizers have a duty-cycle trimmer for
their square-wave outputs, and that trimmer can be set by ear; the 50% point was distinctive, because
even-numbered harmonics essentially disappear at 50%.
A new class of audio amplifiers based on the PWM principle is becoming popular. Called "Class-D amplifiers",
these amplifiers produce a PWM equivalent of the analog input signal which is fed to the loudspeaker via a
suitable filter network to block the carrier and recover the original audio. These amplifiers are characterized
by very good efficiency figures (≥ 90%) and compact size/light weight for large power outputs. For a few
decades, industrial and military PWM amplifiers have been in common use, often for driving servo motors.
They offer very good efficiency, commonly well above 90%. Field-gradient coils in MRI machines are driven
by relatively-high-power PWM amplifiers.
Historically, a crude form of PWM has been used to play back PCM digital sound on the PC speaker, which is
driven by only two voltage levels, typically 0 V and 5 V. By carefully timing the duration of the pulses, and
by relying on the speaker's physical filtering properties (limited frequency response, self-inductance, etc.) it
was possible to obtain an approximate playback of mono PCM samples, although at a very low quality, and
with greatly varying results between implementations.
In more recent times, the Direct Stream Digital sound encoding method was introduced, which uses a
generalized form of pulse-width modulation called pulse density modulation, at a high enough sampling rate
(typically in the order of MHz) to cover the whole acoustic frequencies range with sufficient fidelity. This
method is used in the SACD format, and reproduction of the encoded audio signal is essentially similar to
the method used in class-D amplifiers.
References
1. Schönung, A.; Stemmler, H. (August 1964). "Geregelter Drehstrom-Umkehrantrieb mit
gesteuertem Umrichter nach dem Unterschwingungsverfahren". BBC Mitteilungen (Brown
Boveri et Cie) 51 (8/9): 555–577.
2. www.netrino.com – Introduction to Pulse Width Modulation (PWM)
3. Fundamentals of HVAC Control Systems, by Robert McDowall, p. 21
Induction motor
Three-phase induction motors
An induction motor or asynchronous motor is a type of alternating current motor where power is
supplied to the rotor by means of electromagnetic induction.[1]
An electric motor turns because of magnetic force exerted between a stationary electromagnet called the
stator and a rotating electromagnet called the rotor. Different types of electric motors are distinguished by
how electric current is supplied to the moving rotor. In a DC motor and a slip-ring AC motor, current is
provided to the rotor directly through sliding electrical contacts called commutators and slip rings. In an
induction motor, by contrast, the current is induced in the rotor without contacts by the magnetic field of the
stator, through electromagnetic induction. An induction motor is sometimes called a rotating transformer
because the stator (stationary part) is essentially the primary side of the transformer and the rotor (rotating
part) is the secondary side. Unlike the normal transformer which changes the current by using time varying
flux, induction motors use rotating magnetic fields to transform the voltage. The current in the primary side
creates an electromagnetic field which interacts with the electromagnetic field of the secondary side to
produce a resultant torque, thereby transforming the electrical energy into mechanical energy. Induction
motors are widely used, especially polyphase induction motors, which are frequently used in industrial
drives.
Induction motors are now the preferred choice for industrial motors due to their rugged construction,
absence of brushes (which are required in most DC motors) and—thanks to modern power electronics—the
ability to control the speed of the motor.
History
The first induction motors were realized by Galileo Ferraris in 1885 in Italy. In 1888, Ferraris published his
research in a paper to the Royal Academy of Sciences in Turin (later, in the same year, Nikola Tesla gained
U.S. Patent 381,968) where he exposed the theoretical foundations for understanding the way the motor
operates.[2] The induction motor with a cage was invented by Mikhail Dolivo-Dobrovolsky about a year later.
The basic difference between an induction motor and a synchronous AC motor is that in the latter a current
is supplied into the rotor (usually DC) which in turn creates a (circular uniform) magnetic field around the
rotor. The rotating magnetic field of the stator will impose an electromagnetic torque on the still magnetic
field of the rotor causing it to move (about a shaft) and rotation of the rotor is produced. It is called
synchronous because at steady state the speed of the rotor is the same as the speed of the rotating
magnetic field in the stator.
By way of contrast, the induction motor does not have any direct supply onto the rotor; instead, a
secondary current is induced in the rotor. To achieve this, stator windings are arranged around the rotor so
that when energised with a polyphase supply they create a rotating magnetic field pattern which sweeps
past the rotor. This changing magnetic field pattern induces current in the rotor conductors. These currents
interact with the rotating magnetic field created by the stator and in effect causes a rotational motion on the
rotor.
However, for these currents to be induced, the speed of the physical rotor must be less than the speed of
the rotating magnetic field in the stator or else the magnetic field will not be moving relative to the rotor
conductors and no currents will be induced. If by some chance this happens, the rotor typically slows slightly
until a current is re-induced and then the rotor continues as before. This difference between the speed of
the rotor and speed of the rotating magnetic field in the stator is called slip. It is unitless and is the ratio
between the relative speed of the magnetic field as seen by the rotor (the slip speed) to the speed of the
rotating stator field. Due to this, an induction motor is sometimes referred to as an asynchronous machine.
AC Induction Motor
where
A synchronous motor always runs at synchronous speed with 0% slip. The speed of a synchronous motor is
determined by the following formula:
where v is the speed of the rotor (in rpm), f is the frequency of the AC supply (in Hz) and p is the number of
magnetic poles.[3]
For example, a 6 pole motor operating on 60 Hz power would have a speed of:
Note on the use of p - some texts refer to number of pole pairs per phase instead of number of poles per
phase. For example a 6 pole motor, operating on 60 Hz power, would have 3 pole pairs. The equation of
synchronous speed then becomes:
Construction
The stator consists of wound 'poles' that carry the supply current to induce a magnetic field that penetrates
the rotor. In a very simple motor, there would be a single projecting piece of the stator (a salient pole) for
each pole, with windings around it; in fact, to optimize the distribution of the magnetic field, the windings
are distributed in many slots located around the stator, but the magnetic field still has the same number of
north-south alternations. The number of 'poles' can vary between motor types but the poles are always in
pairs (i.e. 2, 4, 6, etc.).
Induction motors are most commonly built to run on single-phase or three-phase power, but two-phase
motors also exist. In theory, two-phase and more than three phase induction motors are possible; many
single-phase motors having two windings and requiring a capacitor can actually be viewed as two-phase
motors, since the capacitor generates a second power phase 90 degrees from the single-phase supply and
feeds it to a separate motor winding. Single-phase power is more widely available in residential buildings,
but cannot produce a rotating field in the motor ( the field merely oscillates back and forth), so single-phase
induction motors must incorporate some kind of starting mechanism to produce a rotating field. They would,
using the simplified analogy of salient poles, have one salient pole per pole number; a four-pole motor
would have four salient poles. Three-phase motors have three salient poles per pole number, so a four-pole
motor would have twelve salient poles. This allows the motor to produce a rotating field, allowing the motor
to start with no extra equipment and run more efficiently than a similar single-phase motor.
There are three types of rotor:
Squirrel-cage rotor
The most common rotor is a squirrel-cage rotor. It is made up of bars of either solid copper (most common)
or aluminum that span the length of the rotor, and those solid copper or aluminium strips can be shorted or
connected by a ring or some times not, i.e. the rotor can be closed or semiclosed type. The rotor bars in
squirrel-cage induction motors are not straight, but have some skew to reduce noise and harmonics.
A slip ring rotor replaces the bars of the squirrel-cage rotor with windings that are connected to slip rings.
When these slip rings are shorted, the rotor behaves similarly to a squirrel-cage rotor; they can also be
connected to resistors to produce a high-resistance rotor circuit, which can be beneficial in starting
A rotor can be made from a solid mild steel. The induced current causes the rotation.
Speed control
The synchronous rotational speed of the rotor (i.e. the theoretical unloaded speed with no slip) is controlled
by the number of pole pairs (number of windings in the stator) and by the frequency of the supply voltage.
Under load, the speed of the induction motor varies according to size of the load. As the load is increased,
the speed of the motor decreases, increasing the slip, which increases the field strength of the rotor to bear
the extra load. Before the development of economical semiconductor power electronics, it was difficult to
vary the frequency to the motor and induction motors were mainly used in fixed speed applications. As an
induction motor has no brushes and is easy to control, many older DC motors are now being replaced with
THR induction motors and accompanying inverters in industrial applications.
In a single phase induction motor, it is necessary to provide a starting circuit to start rotation of the rotor. If
this is not done, rotation may be commenced by manually giving a slight turn to the rotor. The single phase
induction motor may rotate in either direction and it is only the starting circuit which determines rotational
direction.
For small motors of a few watts, the start rotation is done by means of one or two single turn(s) of heavy
copper wire around one corner of the pole. The current induced in the single turn is out of phase with the
supply current and so causes an out-of-phase component in the magnetic field, which imparts to the field
sufficient rotational character to start the motor. Starting torque is very low and efficiency is also reduced.
Such shaded-pole motors are typically used in low-power applications with low or zero starting torque
requirements, such as desk fans and record players.
Larger motors are provided with a second stator winding which is fed with an out-of-phase current to create
a rotating magnetic field. The out-of-phase current may be derived by feeding the winding through a
capacitor or it may derive from the winding having different values of inductance and resistance from the
main winding.
In some designs, the second winding is disconnected once the motor is up to speed, usually either by means
of a switch operated by centrifugal force acting on weights on the motor shaft or by a positive temperature
coefficient thermistor which, after a few seconds of operation, heats up and increases its resistance to a high
value thereby reducing the current through the second winding to an insignificant level. Other designs keep
the second winding continuously energised when running, which improves torque.
Sources
Henri Boy de la Tour (1906). The induction motor: its theory and design, set forth by a practical
method of calculation. Translated Cyprien Odilon Mailloux. McGraw Pub. Co..
http://books.google.com/books?id=hbM_AAAAYAAJ&printsec=frontcover&dq=induction+motor
&source=bl&ots=_JgDsnjN2s&sig=LHXibhTQ9XXIOvzsWATRSHA-
xkA&hl=en&ei=X1O3TOekFpCisAPomqGeCQ&sa=X&oi=book_result&ct=result&resnum=14&sqi
=2&ved=0CFoQ6AEwDQ#v=onepage&q&f=false.
Benjamin Franklin Bailey (1911). The induction motor. McGraw-Hill.
http://books.google.com/books?id=r_dOAAAAMAAJ&printsec=frontcover&dq=induction+motor
&source=bl&ots=g7Th09trR-
&sig=onxjvgyC920oARs_LUDqnzV2kHg&hl=en&ei=1VS3TNTyNoKKlwfWwJ3MDA&sa=X&oi=book
_result&ct=result&resnum=4&ved=0CDcQ6AEwAzgK#v=onepage&q&f=false.
Bernhard Arthur Behrend (1901). The induction motor: A short treatise on its theory and design,
with numerous experimental data and diagrams. Electrical world and engineer.
http://books.google.com/books?id=ffpOAAAAMAAJ&printsec=frontcover&dq=induction+motor
&source=bl&ots=AWJzYuRVCl&sig=Bm0VKBdRKgCfTPpeR5_YU3BCrso&hl=en&ei=1VS3TNTyNoK
KlwfWwJ3MDA&sa=X&oi=book_result&ct=result&resnum=7&ved=0CEUQ6AEwBjgK#v=onepage
&q&f=false.
References
1. http://www.wisegeek.com/what-is-an-induction-motor.htm
2. http://www.fi.edu/learn/case-files/tesla/motor.html
3. http://www.electricmotors.machinedesign.com/guiEdits/Content/bdeee11/bdeee11_7.aspx
Synchronous motor
A synchronous electric motor is an AC motor distinguished by a rotor spinning with coils passing magnets
at the same rate as the alternating current and resulting rotating magnetic field which drives it. Another way
of saying this is that it has zero slip under usual operating conditions. Contrast this with an induction motor,
which must slip in order to produce torque. They operate synchronously with line frequency. As with
squirrel-cage induction motors, speed is determined by the number of pairs of poles and the line frequency.
There are two major types of synchronous motors: non-excited and direct-current excited.
Non-excited motors are manufactured in reluctance and hysteresis designs, these motors employ a self-
starting circuit and require no external excitation supply.
Reluctance designs have ratings that range from sub-fractional to about 30 hp. Sub-fractional horsepower
motors have low torque, and are generally used for instrumentation applications. Moderate torque, integral
horsepower motors use squirrel- cage construction with toothed rotors. When used with an adjustable
frequency power supply, all motors in the drive system can be controlled at exactly the same speed. The
power supply frequency determines motor operating speed.
Hysteresis motors are manufactured in sub-fractional horsepower ratings, primarily as servomotors and
timing motors. More expensive than the reluctance type, hysteresis motors are used where precise constant
speed is required.
DC-excited motors — Made in sizes larger than 1 hp, these motors require direct current supplied through
slip rings for excitation. The direct current can be supplied from a separate source or from a dc generator
directly connected to the motor shaft
Slip rings and brushes are used to conduct current to the rotor. The rotor poles connect to each other and
move at the same speed - hence the name synchronous motor.
Synchronous motors fall under the category of synchronous machines which also includes the alternator
(synchronous generator). These machines are commonly used in analog electric clocks, timers and other
devices where correct time is required.
where v is the speed of the rotor (in rpm), f is the frequency of the AC supply (in Hz) and n is the number
of magnetic poles.
Parts
A synchronous motor is composed of the following parts:
The stator is the outer shell of the motor, which carries the armature winding. This winding is
spatially distributed for poly-phase AC current. This armature creates a rotating magnetic field
inside the motor.
The rotor is the rotating portion of the motor. it carries field winding, which may be supplied by
a DC source. On excitation, this field winding behaves as a permanent magnet.
The slip rings in the rotor, to supply the DC to the field winding, in the case of DC excited types
Operation
The operation of a synchronous motor is simple to imagine. The armature winding, when excited by a poly-
phase (usually 3-phase)Supply, creates a rotating magnetic field inside the motor. The field winding, which
acts as a permanent magnet, simply locks in with the rotating magnetic field and rotates along with it.
During operation, as the field locks in with the rotating magnetic field, the motor is said to be in
synchronization.
Once the motor is in operation, the speed of the motor is dependent only on the supply frequency. When the
motor load is increased beyond the break down load, the motor falls out of synchronization i.e., the applied
load is large enough to pull out the field winding from following the rotating magnetic field. The motor
immediately stalls after it falls out of synchronization.
Starting methods
Synchronous motors are not self-starting motors. This property is due to the inertia of the rotor. When the
power supply is switched on, the armature winding and field windings are excited. Instantaneously, the
armature winding creates a rotating magnetic field, which revolves at the designated motor speed. The
rotor, due to inertia, will not follow the revolving magnetic field. In practice, the rotor should be rotated by
some other means near to the motor's synchronous speed to overcome the inertia. Once the rotor nears the
synchronous speed, the field winding is excited, and the motor pulls into synchronization.
A separate motor (called pony motor) is used to drive the rotor before it locks in into
synchronization.
The field winding is shunted or induction motor like arrangements are made so that the
synchronous motor starts as an induction motor and locks in to synchronization once it reaches
speeds near its synchronous speed.
Reducing the input electrical frequency to get the motor starting slowly, Variable-frequency
drives can be used here which have Rectifier-Inverter circuits or Cycloconverter circuits.
Special Properties
Synchronous motors show some interesting properties, which finds applications in power factor correction.
The synchronous motor can be run at lagging, unity or leading power factor. The control is with the field
excitation, as described below:
When the field excitation voltage is decreased, the motor runs in lagging power factor. The
power factor by which the motor lags varies directly with the drop in excitation voltage. This
condition is called under-excitation.
When the field excitation voltage is made equal to the rated voltage, the motor runs at unity
power factor.
When the field excitation voltage is increased above the rated voltage, the motor runs at leading
power factor. And the power factor by which the motor leads varies directly with the increase in
field excitation voltage. This condition is called over-excitation.
The most basic property of synchro motor is that it can be use both as a capacitor or inductor.
Hence in turn it improves the power factor of system.
The leading power factor operation of synchronous motor finds application in power factor correction.
Normally, all the loads connected to the power supply grid run in lagging power factor, which increases
reactive power consumption in the grid, thus contributing to additional losses. In such cases, a synchronous
motor with no load is connected to the grid and is run over-excited, so that the leading power factor created
by synchronous motor compensates the existing lagging power factor in the grid and the overall power
factor is brought close to 1 (unity power factor). If unity power factor is maintained in a grid, reactive power
losses diminish to zero, increasing the efficiency of the grid. This operation of synchronous motor in over-
excited mode to correct the power factor is sometimes called as Synchronous condenser.
Uses
Synchronous motors find applications in all industrial applications where constant speed is
necessary.
Improving the power factor as Synchronous condensers.
Electrical power plants almost always use synchronous generators because it is important to
keep the frequency constant at which the generator is connected.
Low power applications include positioning machines, where high precision is required, and
robot actuators.
Advantages
Synchronous motors have the following advantages over non-synchronous motors:
Examples
brushless DC electric motor.
stepper motor.
Three-phase AC synchronous motors.
Switched reluctance motor.
Rotor
Rotor and stator of an electric motor
The rotor is the non-stationary part of a rotary electric motor, electric generator or alternator, which rotates
because the wires and magnetic field of the motor are arranged so that a torque is developed about the
rotor's axis. In some designs, the rotor can act to serve as the motor's armature, across which the input
voltage is supplied. The stationary part of an electric motor is the stator. A common problem is called
cogging torque.
Armature
A DC armature.
In electrical engineering, an armature generally refers to one of the two principal electrical components of
an electromechanical machine– a motor or generator, but may also mean the pole piece of a permanent
magnet or electromagnet, or the moving iron part of a solenoid or relay. The other component is the field
winding or field magnet. The role of the "field" component is simply to create a magnetic field (magnetic
flux) for the armature to interact with, so this component can comprise either permanent magnets, or
electromagnets formed by a conducting coil. The armature, in contrast, must carry current so it is always a
conductor or a conductive coil, oriented normal to both the field and to the direction of motion, torque
(rotating machine), or force (linear machine). The armature's role is two-fold. The first is to carry current
crossing the field, thus creating shaft torque in a rotating machine or force in a linear machine. The second
role is to generate an electromotive force (EMF).
In the armature, an electromotive force is created by the relative motion of the armature and the field.
When the machine is acting as a motor, this EMF opposes the armature current, and the armature converts
electrical power to mechanical torque, and power, unless the machine is stalled, and transfers it to the load
via the shaft. When the machine is acting as a generator, the armature EMF drives the armature current,
and shaft mechanical power is converted to electrical power and transferred to the load. In an induction
generator, these distinctions are blurred, since the generated power is drawn from the stator, which would
normally be considered the field.
A growler is used to check the armature for shorts, opens and grounds.
Terminology
The parts of an alternator or related equipment can be expressed in either mechanical terms or electrical
terms. Although distinctly separate, these two sets of terminology are frequently used interchangeably or in
combinations that include one mechanical term and one electrical term. This may cause confusion when
working with compound machines such as brushless alternators, or in conversation among people who are
accustomed to work with differently configured machinery.
In alternating current machines, the armature is usually stationary, and is known as the stator winding. In
DC rotating machines other than brushless DC machines, it is usually rotating, and is known as the rotor.
The pole piece of a permanent magnet or electromagnet and the moving, iron part of a solenoid, especially
if the latter acts as a switch or relay, may also be referred to as armatures.
Mechanical
Rotor: The rotating part of an alternator, generator, dynamo or motor.
Stator: The stationary part of an alternator, generator, dynamo or motor
Electrical
Armature: The power-producing component of an alternator, generator, dynamo or motor. The armature
can be on either the rotor or the stator.
Field: The magnetic field component of an alternator, generator, dynamo or motor. The field can be on
either the rotor or the stator and can be either an electromagnet or a permanent magnet.
The demagnetizing effect can be overcome by adding extra ampere-turns on the main field. The cross
magnetizing effect can be reduced by having common poles.
Since an armature is wound with coils of wire, a magnetic field is set up in the armature whenever a current
flows in the coils. This field is at right angles to the generator field, and is called cross magnetization of the
armature. The effect of the armature field is to distort the generator field and shift the neutral plane. The
neutral plane is the position where the armature windings are moving parallel to the magnetic flux lines.
This effect is known as armature reaction and is proportional to the current flowing in the armature coils.
The brushes of a generator must be set in the neutral plane; that is, they must contact segments of the
commutator that are connected to armature coils having no induced emf. If the brushes were contacting
commutator segments outside the neutral plane, they would short-circuit "live" coils and cause arcing and
loss of power.
Armature reaction causes the neutral plane to shift in the direction of rotation, and if the brushes are in the
neutral plane at no load, that is, when no armature current is flowing, they will not be in the neutral plane
when armature current is flowing. For this reason it is desirable to incorporate a corrective system into the
generator design.
These are two principal methods by which the effect of armature reaction is overcome. The first method is to
shift the position of the brushes so that they are in the neutral plane when the generator is producing its
normal load current. in the other method, special field poles, called interpoles, are installed in the generator
to counteract the effect of armature reaction.
The brush-setting method is satisfactory in installations in which the generator operates under a fairly
constant load. If the load varies to a marked degree, the neutral plane will shift proportionately, and the
brushes will not be in the correct position at all times. The brush-setting method is the most common means
of correcting for armature reaction in small generators (those producing approximately 1000 W or less).
Larger generators require the use of interpoles.
Balancing machine
A balancing machine is a measuring tool used for balancing rotating machine parts such as rotors for
electric motors, fans, turbines, disc brakes, disc drives, propellers and pumps. The machine usually consists
of two rigid pedestals, with suspension and bearings on top supporting a mounting platform. The unit under
test is bolted to the platform and is rotated either with a belt-, air-, or end-drive. As the part is rotated, the
vibration in the suspension is detected with sensors and that information is used to determine the amount of
unbalance in the part. Along with phase information, the machine can determine how much and where to
add weights to balance the part.
In a hard-bearing machine, balancing is done at a frequency lower than the resonance frequency of the
suspension. In a soft-bearing machine, balancing is done at a frequency higher than the resonance
frequency of the suspension. Both types of machines have various advantages and disadvantages. A hard-
bearing machine is generally more versatile and can handle pieces with greatly varying weights, because
hard-bearing machines are measuring centrifugal forces and require only a one-time calibration. Only five
geometric dimensions need to be fed into the measuring unit and the machine is ready for use. Therefore, it
works very well for low- and middle-size volume production and in repair workshops.
A soft-bearing machine is not so versatile with respect to amount of rotor weight to be balanced. The
preparation of a soft-bearing machine for individual rotor types is more time consuming, because it needs to
be calibrated for different part types. It is very suitable for high-production volume and high-precision
balancing tasks.
Hard- and soft-bearing machines can be automated to remove weight automatically, such as by drilling or
milling, but hard-bearing machines are more robust and reliable. Both machine principles can be integrated
into a production line and loaded by a robot arm or gantry, requiring very little human control.
How it works
With the rotating part resting on the bearings, a vibration sensor is attached to the suspension. In most
soft-bearing machines, a velocity sensor is used. This sensor works by moving a magnet in relation to a
fixed coil that generates voltage proportional to the velocity of the vibration. Accelerometers, which measure
acceleration of the vibration, can also be used.
A photocell (sometimes called a phaser), proximity sensor, or encoder is used to determine the rotational
speed, as well as the relative phase of the rotating part. This phase information is then used to filter the
vibration information to determine the amount of movement, or force, in one rotation of the part. Also, the
time difference between the phase and the vibration peak gives the angle at which the unbalance exists.
Amount of unbalance and angle of unbalance give an unbalance vector.
Calibration is performed by adding a known weight at a known angle. In a soft-bearing machine, trial
weights must be added in correction planes for each part. This is because the location of the correction
planes along the rotational axis is unknown, and therefore it is unknown how much a given amount of
weight will affect the balance. By using trial weights, you are adding a known weight at a known angle and
getting the unbalance vector caused by it. This vector is then compared to the original unbalance vector to
find the resultant vector, which gives the weight and angles needed to bring the part into balance. In a
hard-bearing machine, the location of the correction plane must be given in advance so that the machine
always knows how much a given amount of weight will affect the balance.
A blade balancing machine attempts to balance a part in assembly, so minimal correction is required later
on. Blade balancers are used on parts such as fans, propellers, and turbines. On a blade balancer, each
blade to be assembled is weighed and its weight entered into a balancing software package. The software
then sorts the blades and attempts to find the blade arrangement with the least amount of unbalance.
Portable balancing machines are used to balance parts that cannot be taken apart and put on a
balancing machine, usually parts that are currently in operation such as turbines, pumps, and motors.
Portable balancers come with displacement sensors, such as accelerometers, and a photocell, which are then
mounted to the pedestals or enclosure of the running part. Based on the vibrations detected, they calculate
the parts unbalance. Many times these devices contain a spectrum analyzer so the part condition can be
monitored without the use of a photocell and non-rotational vibration can be analyzed.
Contactor
Contactors range from those having a breaking current of several amps and 24 V DC to thousands of amps
and many kilovolts. The physical size of contactors ranges from a device small enough to pick up with one
hand, to large devices approximately a meter (yard) on a side.
Contactors are used to control electric motors, lighting, heating, capacitor banks, and other electrical loads.
Construction
A contactor is composed of three different items. The contacts are the current carrying part of the contactor.
This includes power contacts, auxiliary contacts, and contact springs. The electromagnet provides the
driving force to close the contacts. The enclosure is a frame housing the contact and the electromagnet.
Enclosures are made of insulating materials like Bakelite, Nylon 6, and thermosetting plastics to protect and
insulate the contacts and to provide some measure of protection against personnel touching the contacts.
Open-frame contactors may have a further enclosure to protect against dust, oil, explosion hazards and
weather.
High voltage contactors (greater than 1000 volts) may use vacuum or an inert gas around the contacts.
Magnetic blowouts use blowout coils to lengthen and move the electric arc. These are especially useful in DC
power circuits. AC arcs have periods of low current, during which the arc can be extinguished with relative
ease, but DC arcs have continuous high current, so blowing them out requires the arc to be stretched
further than an AC arc of the same current. The magnetic blowouts in the pictured Albright contactor (which
is designed for DC currents) more than double the current it can break, increasing it from 600 A to 1,500 A.
Sometimes an economizer circuit is also installed to reduce the power required to keep a contactor closed;
an auxiliary contact reduces coil current after the contactor closes. A somewhat greater amount of power is
required to initially close a contactor than is required to keep it closed. Such a circuit can save a substantial
amount of power and allow the energized coil to stay cooler. Economizer circuits are nearly always applied
on direct-current contactor coils and on large alternating current contactor coils.
A basic contactor will have a coil input (which may be driven by either an AC or DC supply depending on the
contactor design). The coil may be energized at the same voltage as the motor, or may be separately
controlled with a lower coil voltage better suited to control by programmable controllers and lower-voltage
pilot devices. Certain contactors have series coils connected in the motor circuit; these are used, for
example, for automatic acceleration control, where the next stage of resistance is not cut out until the motor
current has dropped.
Operating principle
Unlike general-purpose relays, contactors are designed to be directly connected to high-current load
devices. Relays tend to be of lower capacity and are usually designed for both normally closed and normally
open applications. Devices switching more than 15 amperes or in circuits rated more than a few kilowatts
are usually called contactors. Apart from optional auxiliary low current contacts, contactors are almost
exclusively fitted with normally open contacts. Unlike relays, contactors are designed with features to control
and suppress the arc produced when interrupting heavy motor currents.
When current passes through the electromagnet, a magnetic field is produced, which attracts the moving
core of the contactor. The electromagnet coil draws more current initially, until its inductance increases
when the metal core enters the coil. The moving contact is propelled by the moving core; the force
developed by the electromagnet holds the moving and fixed contacts together. When the contactor coil is
de-energized, gravity or a spring returns the electromagnet core to its initial position and opens the
contacts.
For contactors energized with alternating current, a small part of the core is surrounded with a shading coil,
which slightly delays the magnetic flux in the core. The effect is to average out the alternating pull of the
magnetic field and so prevent the core from buzzing at twice line frequency.
Most motor control contactors at low voltages (600 volts and less) are air break contactors; i.e., ordinary air
surrounds the contacts and extinguishes the arc when interrupting the circuit. Modern medium-voltage
motor controllers use vacuum contactors.
Motor control contactors can be fitted with short-circuit protection (fuses or circuit breakers), disconnecting
means, overload relays and an enclosure to make a combination starter.
Ratings
Contactors are rated by designed load current per contact (pole),[3] maximum fault withstand current, duty
cycle, voltage, and coil voltage. A general purpose motor control contactor may be suitable for heavy
starting duty on large motors; so-called "definite purpose" contactors are carefully adapted to such
applications as air-conditioning compressor motor starting. North American and European ratings for
contactors follow different philosophies, with North American general purpose machine tool contactors
generally emphasizing simplicity of application while definite purpose and European rating philosophy
emphasizes design for the intended life cycle of the application.
Contactors are rated by designed load current per contact pole, maximum fault withstand current, duty
cycle, voltage, and coil voltage. A general purpose motor control contactor may be suitable for heavy
starting duty on large motors; so-called "definite purpose" contactors are carefully adapted to such
applications as air-conditioning compressor motor starting. North American and European ratings for
contactors follow different philosophies, with North American general purpose machine tool contactors
generally emphasizing simplicity of application while definite purpose and European rating philosophy
emphasizes design for the intended life cycle of the application.
Current rating of the contactor depends on utilization category. For example IEC Categories are
described as:
Applications
Lighting control
Contactors are often used to provide central control of large lighting installations, such as an office building
or retail building. To reduce power consumption in the contactor coils, latching contactors are used, which
have two operating coils. One coil, momentarily energized, closes the power circuit contacts, which are then
mechanically held closed; the second coil opens the contacts.
Magnetic starter
A magnetic starter is a contactor designed to provide power to electric motors. The magnetic starter has
an overload relay, which will open the control voltage to the starter coil if it detects an overload on a motor.
Overload relays may rely on heat produced by the motor current to operate a bimetal contact or release a
contact held closed by a low-melting-point alloy. The overload relay opens a set of contacts that are wired in
series with the supply to the contactor feeding the motor. The characteristics of the heaters can be matched
to the motor so that the motor is protected against overload. Recently, microprocessor-controlled motor
digital protective relays relays offer more comprehensive protection of motors.
Applications
Every electric motor has to have some sort of controller. The motor controller will have differing features
and complexity depending on the task that the motor will be performing.
The simplest case is a switch to connect a motor to a power source, such as in small appliances or power
tools. The switch may be manually operated or may be a relay or contactor connected to some form of
sensor to automatically start and stop the motor. The switch may have several positions to select different
connections of the motor. This may allow reduced-voltage starting of the motor, reversing control or
selection of multiple speeds. Overload and overcurrent protection may be omitted in very small motor
controllers, which rely on the supplying circuit to have overcurrent protection. Small motors may have built-
in overload devices to automatically open the circuit on overload. Larger motors have a protective overload
relay or temperature sensing relay included in the controller and fuses or circuit breakers for overcurrent
protection. An automatic motor controller may also include limit switches or other devices to protect the
driven machinery.
More complex motor controllers may be used to accurately control the speed and torque of the connected
motor (or motors) and may be part of closed loop control systems for precise positioning of a driven
machine. For example, a numerically controlled lathe will accurately position the cutting tool according to a
preprogrammed profile and compensate for varying load conditions and perturbing forces to maintain tool
position.
An electric motor controller can be classified by the type of motor it is to drive such as permanent magnet,
servo, series, separately excited, and alternating current.
A motor controller is connected to a power source such as a battery pack or power supply, and control
circuitry in the form of analog or digital input signals.
Motor starters
A small motor can be started by simply plugging it into an electrical receptacle or by using a switch or circuit
breaker. A larger motor requires a specialized switching unit called a motor starter or motor contactor. When
energized, a direct on line (DOL) starter immediately connects the motor terminals directly to the power
supply. A motor soft starter connects the motor to the power supply through a voltage reduction device and
increases the applied voltage gradually or in steps
Adjustable-speed drives
A small, early 1960's-vintage motor control center for 480 volt motors.
A motor control center (MCC) is an assembly of one or more enclosed sections having a common power bus
and principally containing motor control units.[1] Motor control centers are in modern practice a factory
assembly of several motor starters. A motor control center can include variable frequency drives,
programmable controllers, and metering and may also be the electrical service entrance for the building.
Motor control centers are usually used for low voltage three-phase alternating current motors from 230 volts
to 600 volts. Medium-voltage motor control centers are made for large motors running at 2300 V to around
15000 V, using vacuum contactors for switching and with separate compartments for power switching and
control.[5]
Motor control centers have been used since 1950 by the automobile manufacturing industry which used
large numbers of electric motors. Today they are used in many industrial and commercial applications.
Where very dusty or corrosive processes are used, the motor control center may be installed in a separate
air-conditioned room, but often an MCC will be on the factory floor adjacent to the machinery controlled.
A motor control center consists of one or more vertical metal cabinet sections with power bus and provision
for plug-in mounting of individual motor controllers. Very large controllers may be bolted in place but
smaller controllers can be unplugged from the cabinet for testing or maintenance. Each motor controller
contains a contactor or a solid-state motor controller, overload relays to protect the motor, fuses or a circuit
breaker to provide short-circuit protection, and a disconnecting switch to isolate the motor circuit. Three-
phase power enters each controller through separable connectors. The motor is wired to terminals in the
controller. Motor control centers provide wire ways for field control and power cables.
Each motor controller in an MCC can be specified with a range of options such as separate control
transformers, pilot lamps, control switches, extra control terminal blocks, various types of bi-metal and
solid-state overload protection relays, or various classes of power fuses or types of circuit breakers. A motor
control center can either be supplied ready for the customer to connect all field wiring, or can be an
engineered assembly with internal control and interlocking wiring to a central control terminal panel board
or programmable controller.
Motor control centers (MCC) usually sit on floors, which are often required to have a fire-resistance rating.
Firestops may be required for cables that penetrate fire-rated floors and walls.
Phase vector drives (or simply vector drives) are an improvement over variable frequency drives (VFDs)
in that they separate the calculations of magnetizing current and torque generating current. These
quantities are represented by phase vectors, and are combined to produce the driving phase vector which in
turn is decomposed into the driving components of the output stage. These calculations need a fast
microprocessor, typically a DSP device.
Unlike a VFD, a vector drive is a closed loop system. It takes feedback on rotor position and phase currents.
Rotor position can be obtained through an encoder, but is often sensed by the reverse EMF generated on the
motor leads.
In some configurations, a vector drive may be able to generate full rated motor torque at zero speed.
Direct torque control has better torque control dynamics than the PI-current controller based vector control.
Thus it suits better to servo control applications. However, it has some advantage over other control
methods in other applications as well because due to the faster control it has better capabilities to damp
mechanical resonances and thus extend the life of the mechanical system.
These controls are applicable to brushed DC motors with either a wound or permanent magnet stator. A
valuable characteristic of these motors is that they are easily controlled in torque, the torque being fairly
directly proportional to the driving current. Speed control is derived by simply modulating the motor torque.
SCR controls for DC motors convert AC power to direct current, with adjustable voltage. Small DC drives are
common in industry, running from line voltages, with motors rated at 90V for 120V line, and 180V for a
240V line. Larger drives, up to thousands of horsepower, are powered by three phase supplies and are used
in such applications as rolling mills, paper machines, excavators, and ship propulsion. DC drivers are
available in reversing and non-reversing models. The waveform of the current through the motor by a
single-phase drive will have strong ripple components due to the switching at line frequency. This can be
reduced by use of a poly phase supply or smoothing inductors in the motor circuit; otherwise the ripple
currents produce motor heating, excess noise, and loss of motor torque.
PWM controls use pulse width modulation to regulate the current sent to the motor. Unlike SCR controls
which switch at line frequency, PWM controls produce smoother current at higher switching frequencies,
typically between 1 and 20 kHz. At 20 kHz, the switching frequency is inaudible to humans, thereby
eliminating the hum which switching at lower frequency produces. However, some motor controllers for
radio controlled models make use of the motor to produce audible sound, most commonly simple beeps.
A PWM controller typically contains a large reservoir capacitor and an H-bridge arrangement of switching
elements (thyristors, Mosfets, solid state relays, or transistors).
Servo controllers
Servo controllers is a wide category of motor control. Common features are:
Servo motors may be made from several motor types, the most common being
brushed DC motor
brushless DC motors
AC servo motors
Servo controllers use position feedback to close the control loop. This is commonly implemented with
encoders, resolvers, and Hall effect sensors to directly measure the rotor's position.
A servo may be controlled using pulse-width modulation (PWM). How long the pulse remains high (typically
between 1 and 2 milliseconds) determines where the motor will try to position itself. Another control method
is pulse and direction.
Other position feedback methods measure the back EMF in the undriven coils to infer the rotor position, or
detect the Kick-Back voltage transient (spike) that is generated whenever the power to a coil is
instantaneously switched off. These are therefore often called "sensorless" control methods.
Sensorless control methods
Ripple Counting
Ripple counting works on the 'law of induction', or more specifically Lenz's law, which says that the magnetic
field of any induced current opposes the charge that induces it. This so-called back EMF (sometimes called
the counter electromotive force) can be detected by measuring the current flowing through each coil as the
motor rotates.
In a fully encapsulated motor and particularly a multi pole motor this is difficult to measure. Therefore ripple
counting usually relies on measuring the voltage variations over a small resistor inserted in one of the power
supply wires to the motor. The result is a voltage curve representing the accumulated currents running
through the coils of the motor assembly as the motor rotates.
The current ripple waveform characteristics are highly dependent of a number of factors such as the supply
voltage and the actual load, speed, direction and temperature of the motor. Other factors such as the in-
rush current, aging of motor parts and electromagnetic interference can also influence the ripple waveform.
The amplitude and the shape of the waveform can vary significantly due to these factors. In other
applications noise transients superposed onto the ripple current waveform can generate false counting
pulses.
It has proven difficult to design a detection system based on ripple counting that can be used to precisely
and reliably count the number of commutations of a rotating motor from start to stop. Numerous attempts
to seek to improve the reliability of ripple counting have been described in the literature, examples in [7] [8].
Transient Counting
Transient counting works on the basic principle of Ohm's law and the behavior of a collapsing magnetic field
in which a Back-Fire or Kick-Back transient (spike) is generated whenever the power to a coil is
instantaneously switched off
At each commutation point, when the brush breaks contact with a commutation segment, the energy stored
in the motor winding as a magnetic field causes an arc or voltage spike between the brush and the
commutator segment. This occurs not only during normal commutation but also in situations where the
brushes bounce on the rotating commutator.
A dedicated transient detector circuit (in effect a high pass filter) detects the Kick-Back spike from the
collapsing magnetic field in the coil when the power to the coil is turned off. The Kick-Back transients trigger
the modulation of an electronic encoder signal for each of the motor commutations. Thus an N pole motor
will encode N signals per rotation. The Kick-Back spikes can be measured anywhere on the power supply
wires to the motor. The encoded signal can be used as position feedback in the servo controller.
The performance of transient counting is by and large unaffected by the parameters which are influencing
ripple counting. Whether the motor is powered or is coasting in generator mode driven by the inertia of a
load has no influence on the counting reliability. The amplitude of the Kick-Back transients is mainly
influenced by the conductivity of the surrounding air. This is because the intensity of the arc generated
between a brush and a commutator depends on the air conductivity.[2]
DC motors are typically controlled by using a transistor configuration called an "H-bridge". This consists of a
minimum of four mechanical or solid-state switches, such as two NPN and two PNP transistors. One NPN and
one PNP transistor are activated at a time. Both NPN or PNP transistors can be activated to cause a short
across the motor terminals, which can be useful for slowing down the motor from the back EMF it creates.
Variable-frequency drive
A variable-frequency drive (VFD) is a system for controlling the rotational speed of an alternating current
(AC) electric motor by controlling the frequency of the electrical power supplied to the motor. A variable
frequency drive is a specific type of adjustable-speed drive. Variable-frequency drives are also known as
adjustable-frequency drives (AFD), variable-speed drives (VSD), AC drives, microdrives or inverter drives.
Since the voltage is varied along with frequency, these are sometimes also called VVVF (variable voltage
variable frequency) drives.
Variable-frequency drives are widely used. In ventilation systems for large buildings, variable-frequency
motors on fans save energy by allowing the volume of air moved to match the system demand. They are
also used on pumps, elevator, conveyor and machine tool drives.
VFD types
All VFDs use their output devices (IGBTs, transistors, thyristors) only as switches, turning them only on or
off. Using a linear device such as a transistor in its linear mode is impractical for a VFD drive, since the
power dissipated in the drive devices would be about as much as the power delivered to the load.
Constant voltage
Constant current
Cycloconverter
In a constant voltage converter, the intermediate DC link voltage remains approximately constant during
each output cycle. In constant current drives, a large inductor is placed between the input rectifier and the
output bridge, so the current delivered is nearly constant. A cycloconverter has no input rectifier or DC link
and instead connects each output terminal to the appropriate input phase.
The most common type of packaged VF drive is the constant-voltage type, using pulse width modulation to
control both the frequency and effective voltage applied to the motor load.
VFD system
A variable frequency drive system generally consists of an AC motor, a controller and an operator interface.
VFD motor
The motor used in a VFD system is usually a three-phase induction motor. Some types of single-phase
motors can be used, but three-phase motors are usually preferred. Various types of synchronous motors
offer advantages in some situations, but induction motors are suitable for most purposes and are generally
the most economical choice. Motors that are designed for fixed-speed operation are often used. Certain
enhancements to the standard motor designs offer higher reliability and better VFD performance, such as
MG-31 rated motors.
VFD controller
Variable frequency drive controllers are solid state electronic power conversion devices. The usual design
first converts AC input power to DC intermediate power using a rectifier or converter bridge. The rectifier is
usually a three-phase, full-wave-diode bridge. The DC intermediate power is then converted to quasi-
sinusoidal AC power using an inverter switching circuit. The inverter circuit is probably the most important
section of the VFD, changing DC energy into three channels of AC energy that can be used by an AC motor.
These units provide improved power factor, less harmonic distortion, and low sensitivity to the incoming
phase sequencing than older phase controlled converter VFD's. Since incoming power is converted to DC,
many units will accept single-phase as well as three-phase input power (acting as a phase converter as well
as a speed controller); however the unit must be derated when using single phase input as only part of the
rectifier bridge is carrying the connected load.
As new types of semiconductor switches have been introduced, these have promptly been applied to inverter
circuits at all voltage and current ratings for which suitable devices are available. Introduced in the 1980s,
the insulated-gate bipolar transistor (IGBT) became the device used in most VFD inverter circuits in the first
decade of the 21st century.
AC motor characteristics require the applied voltage to be proportionally adjusted whenever the frequency is
changed in order to deliver the rated torque. For example, if a motor is designed to operate at 460 volts at
60 Hz, the applied voltage must be reduced to 230 volts when the frequency is reduced to 30 Hz. Thus the
ratio of volts per hertz must be regulated to a constant value (460/60 = 7.67 V/Hz in this case). For
optimum performance, some further voltage adjustment may be necessary especially at low speeds, but
constant volts per hertz is the general rule. This ratio can be changed in order to change the torque
delivered by the motor.[11]
In addition to this simple volts per hertz control more advanced control methods such as vector control and
direct torque control (DTC) exist. These methods adjust the motor voltage in such a way that the magnetic
flux and mechanical torque of the motor can be precisely controlled.
The usual method used to achieve variable motor voltage is pulse-width modulation (PWM). With PWM
voltage control, the inverter switches are used to construct a quasi-sinusoidal output waveform by a series
of narrow voltage pulses with pseudosinusoidal varying pulse durations.
Operation of the motors above rated name plate speed (base speed) is possible, but is limited to conditions
that do not require more power than nameplate rating of the motor. This is sometimes called "field
weakening" and, for AC motors, means operating at less than rated volts/hertz and above rated name plate
speed. Permanent magnet synchronous motors have quite limited field weakening speed range due to the
constant magnet flux linkage. Wound rotor synchronous motors and induction motors have much wider
speed range. For example, a 100 hp, 460 V, 60 Hz, 1775 RPM (4 pole) induction motor supplied with 460 V,
75 Hz (6.134 V/Hz), would be limited to 60/75 = 80% torque at 125% speed (2218.75 RPM) = 100%
power. At higher speeds the induction motor torque has to be limited further due to the lowering of the
breakaway torque of the motor. Thus rated power can be typically produced only up to 130...150 % of the
rated name plate speed. Wound rotor synchronous motors can be run even higher speeds. In rolling mill
drives often 200...300 % of the base speed is used. Naturally the mechanical strength of the rotor and
lifetime of the bearings is also limiting the maximum speed of the motor. It is recommended to consult the
motor manufacturer if more than 150 % speed is required by the application.
An embedded microprocessor governs the overall operation of the VFD controller. The main microprocessor
programming is in firmware that is inaccessible to the VFD user. However, some degree of configuration
programming and parameter adjustment is usually provided so that the user can customize the VFD
controller to suit specific motor and driven equipment requirements.
VFD operator interface
The operator interface provides a means for an operator to start and stop the motor and adjust the
operating speed. Additional operator control functions might include reversing and switching between
manual speed adjustment and automatic control from an external process control signal. The operator
interface often includes an alphanumeric display and/or indication lights and meters to provide information
about the operation of the drive. An operator interface keypad and display unit is often provided on the front
of the VFD controller as shown in the photograph above. The keypad display can often be cable-connected
and mounted a short distance from the VFD controller. Most are also provided with input and output (I/O)
terminals for connecting pushbuttons, switches and other operator interface devices or control signals. A
serial communications port is also often available to allow the VFD to be configured, adjusted, monitored
and controlled using a computer.
VFD operation
When an induction motor is connected to a full voltage supply, it draws several times (up to about 6 times)
its rated current. As the load accelerates, the available torque usually drops a little and then rises to a peak
while the current remains very high until the motor approaches full speed.
By contrast, when a VFD starts a motor, it initially applies a low frequency and voltage to the motor. The
starting frequency is typically 2 Hz or less. Thus starting at such a low frequency avoids the high inrush
current that occurs when a motor is started by simply applying the utility (mains) voltage by turning on a
switch. After the start of the VFD, the applied frequency and voltage are increased at a controlled rate or
ramped up to accelerate the load without drawing excessive current. This starting method typically allows a
motor to develop 150% of its rated torque while the VFD is drawing less than 50% of its rated current from
the mains in the low speed range. A VFD can be adjusted to produce a steady 150% starting torque from
standstill right up to full speed. Note, however, that cooling of the motor is usually not good in the low
speed range. Thus running at low speeds even with rated torque for long periods is not possible due to
overheating of the motor. If continuous operation with high torque is required in low speeds an external fan
is usually needed. The manufacturer of the motor and/or the VFD should specify the cooling requirements
for this mode of operation.
In principle, the current on the motor side is in direct proportion of the torque that is generated and the
voltage on the motor is in direct proportion of the actual speed, while on the network side, the voltage is
constant, thus the current on line side is in direct proportion of the power drawn by the motor, that is U.I or
C.N where C is torque and N the speed of the motor (we shall consider losses as well, neglected in this
explanation).
With a VFD, the stopping sequence is just the opposite as the starting sequence. The frequency and voltage
applied to the motor are ramped down at a controlled rate. When the frequency approaches zero, the motor
is shut off. A small amount of braking torque is available to help decelerate the load a little faster than it
would stop if the motor were simply switched off and allowed to coast. Additional braking torque can be
obtained by adding a braking circuit (resistor controlled by a transistor) to dissipate the braking energy.
With 4-quadrants recifiers (active-front-end), the VFD is able to brake the load by applying a reverse torque
and reverting the energy back to the network.
However, when either a large number of low-amperage VFDs, or just a few very large-load VFDs are used,
they can have a cumulative negative impact on the AC voltages available to other utility customers in the
same grid.
When the utility voltage becomes misshapen and distorted the losses in other loads such as normal AC
motors are increased. This may in the worst case lead to overheating and shorter operation life. Also
substation transformers and compensation capacitors are affected, the latter especially if resonances are
aroused by the harmonics.
In order to limit the voltage distortion the owner of the VFDs may be required to install filtering equipment
to smooth out the irregular waveform. Alternately, the utility may choose to install filtering equipment of its
own at substations affected by the large amount of VFD equipment being used. In high power installations
decrease of the harmonics can be obtained by supplying the VSDs from transformers that have different
phase shift.
Further, it is possible to use instead of the diode rectifier a similar transistor circuit that is used to control
the motor. This kind of rectifier is called active infeed converter in IEC standards. However, manufacturers
call it by several names such as active rectifier, ISU (IGBT Supply Unit), AFE (Active Front End) or four
quadrant rectifier. With PWM control of the transistors and filter inductors in the supply lines the AC current
can be made nearly sinusoidal. Even better attenuation of the harmonics can be obtained by using an LCL
(inductor-capacitor-inductor) filter instead of single three-phase filter inductor.
Additional advantage of the active infeed converter over the diode bridge is its ability to feed back the
energy from the DC side to the AC grid. Thus no braking resistor is needed and the efficiency of the drive is
improved if the drive is frequently required to brake the motor.
Application considerations
The output voltage of a PWM VFD consists of a train of pulses switched at the carrier frequency. Because of
the rapid rise time of these pulses, transmission line effects of the cable between the drive and motor must
be considered. Since the transmission-line impedance of the cable and motor are different, pulses tend to
reflect back from the motor terminals into the cable. The resulting voltages can produce up to twice the
rated line voltage for long cable runs, putting high stress on the cable and motor winding and eventual
insulation failure. Increasing the cable or motor size/type for long runs and 480v or 600v motors will help
offset the stresses imposed upon the equipment due to the VFD (modern 230v single phase motors not
effected). At 460 V, the maximum recommended cable distances between VFDs and motors can vary by a
factor of 2.5:1. The longer cables distances are allowed at the lower Carrier Switching Frequencies (CSF) of
2.5 kHz. The lower CSF can produce audible noise at the motors. For applications requiring long motor
cables VSD manufacturers usually offer du/dt filters that decrease the steepness of the pulses. For very long
cables or old motors with insufficient winding insulation more efficient sinus filter is recommended. Expect
the older motor's life to shorten. Purchase VFD rated motors for the application.
Further, the rapid rise time of the pulses may cause trouble with the motor bearings. The stray capacitance
of the windings provide paths for high frequency currents that close through the bearings. If the voltage
between the shaft and the shield of the motor exceeds few volts the stored charge is discharged as a small
spark. Repeated sparking causes erosion in the bearing surface that can be seen as fluting pattern. In order
to prevent sparking the motor cable should provide a low impedance return path from the motor frame back
to the inverter. Thus it is essential to use a cable designed to be used with VSDs.[18]
In big motors a slip ring with brush can be used to provide a bypass path for the bearing currents.
Alternatively isolated bearings can be used.
The 2.5 kHz and 5 kHz CSFs cause fewer motor bearing problems than the 20 kHz CSFs.[19] Shorter cables
are recommended at the higher CSF of 20 kHz. The minimum CSF for synchronize tracking of multiple
conveyors is 8 kHz.
The high frequency current ripple in the motor cables may also cause interference with other cabling in the
building. This is another reason to use a motor cable designed for VSDs that has a symmetrical three-phase
structure and good shielding. Further, it is highly recommended to route the motor cables as far away from
signal cables as possible.
Medium voltage drives are generally rated amongst the following voltages : 2.3 kV - 3,3 kV - 4 kV - 6 kV -
11 kV
The in-between voltages are generally possible as well. The power of MV drives is generally in the range of
0,3 to 100 MW however involving a range a several different type of drives with different technologies.
Line regenerative variable frequency drives, showing capacitors (top cylinders)and inductors attached
which filter the regenerated power.
Dynamic braking
Using the motor as a generator to absorb energy from the system is called dynamic braking. Dynamic
braking stops the system more quickly than coasting. Since dynamic braking requires relative motion of the
motor's parts, it becomes less effective at low speed and cannot be used to hold a load at a stopped
position. During braking of an electric motor the electrical energy produced by the motors is dissipated as
heat, inside the rotor of a motor (which is potentially hazardous to life of a electric motor ) so this energy is
usually transferred outside to a bank of onboard resistors. Cooling fans may be used to protect the resistors
from damage. Modern systems have thermal monitoring, so if the temperature of the bank becomes
excessive, it will be switched off.
Cycloconverters and current-source inverters inherently allow return of energy from the load to the line;
voltage-source inverters require an additional converter to return energy to the supply.
Regeneration is only useful in varible-frequency drives where the value of the recovered energy is large
compared to the extra cost of a regenerative system, and if the system requires frequent braking and
starting. An example would be use in conveyor belt during manufacturing where it should stop for every few
minutes, so that the parts can be assembled correctly and moves on. Another example is a crane, where the
hoist motor stops and reverses frequently, and braking is required to slow the load during lowering.
Regenerative variable-frequency drives are widely used where speed control of overhauling loads is
required.
Vector control (also called Field Oriented Control, FOC) is one method used in variable frequency drives to
control the torque (and thus finally the speed) of three-phase AC electric motors by controlling the current
fed to the machine.
Method
The stator phase currents are measured and converted into a corresponding complex (space) vector. This
current vector is then transformed to a coordinate system rotating with the rotor of the machine. For this
the rotor position has to be known. Thus at least speed measurement is required, the position can then be
obtained by integrating the speed.
Then the rotor flux linkage vector is estimated by multiplying the stator current vector with magnetizing
inductance Lm and low-pass filtering the result with the rotor no-load time constant Lr/Rr, that is the ratio of
the rotor inductance to rotor resistance.
Using this rotor flux linkage vector the stator current vector is further transformed into a coordinate system
where the real x-axis is aligned with the rotor flux linkage vector.
Now the real x-axis component of the stator current vector in this rotor flux oriented coordinate system can
be used to control the rotor flux linkage and the imaginary y-axis component can be used to control the
motor torque.
Typically PI-controllers are used to control these currents to their reference values. However, bang-bang
type current control, that gives better dynamics, is also possible.
With PI-controllers the outputs of the controllers are the x-y components of the voltage reference vector for
the stator. Usually due to the cross coupling between the x- and y-axes a decoupling term is further added
to the controller output to improve control performance when big and rapid changes in speed, current and
flux linkage occur. Usually the PI-controller also needs low-pass filtering of either the input or output of the
controller to prevent the current ripple due to transistor switching from being amplified excessively and
unstabilizing the control. Unfortunately, the filtering also limits the dynamics of the control system. Thus
quite high switching frequency (typically more than 10 kHz) is required to allow only minimum filtering for
high performance drives such as servo drives.
Next the voltage references are first transformed to the stationary coordinate system (usually through rotor
d-q coordinates) and then fed into a modulator that using one of the many Pulse Width Modulation (PWM)
algorithms defines the required pulse widths of the stator phase voltages and controls the transistors
(usually IGBTs) of the inverter according to these.
This control method implies the following properties of the control:
Although the vector control algorithm is more complicated than the Direct Torque Control (DTC), the
algorithm is not needed to be calculated as frequently as the DTC algorithm. Also the current sensors need
not be the best in the market. Thus the cost of the processor and other control hardware is lower making it
suitable for applications where the ultimate performance of DTC is not required.
History
Vector control was patented by Felix Blaschke in U.S. Patent 3,824,437 filed originally on August 14, 1969 in
Germany while he worked for Siemens.
In the Blaschke's patent the rotor flux linkage was calculated from the measured air-gap magnetic field.
Thus this method is called direct rotor oriented vector control. However, to use standard induction machines,
the method to estimate the rotor flux linkage from the measured stator currents, as proposed by Hasse, is
more practical. Versions based on flux estimation instead of measuring are called indirect rotor oriented
vector controls. An early review of the possible alternatives was published in the paper:
Blaschke, F., Böhm, K.: Verfahren der Felderfassung bei der Regelung stromrichtergespeister
Asynchronmaschinen. IFAC Symposium: Control in Power Electronics and Electrical Drives,
Düsseldorf, October 7 – 9, 1974, Proceedings Vol I, pp. 635...649.
Vector control has later been dealt with in numerous publications. Several methods have been developed to
make possible the operation without speed or position sensor. Also methods to estimate the rotor time
constant and other parameters have been presented. One good book dealing with these issues is:
Peter Vas: Sensorless Vector and Direct Torque Control, Oxford University Press, 1998, ISBN 0-
19-856465-1
In addition to induction machines, the vector control has also been applied to synchronous machines and
doubly fed machines.
After the major Siemens' patents expired in the end of 80's and beginning of 90's, many other
manufacturers begin to use this method in their products making this the de facto standard in demanding
motor control applications the only alternative being the Direct Torque Control (DTC) developed by ABB.
Method
Stator flux linkage is estimated by integrating the stator voltages. Torque is estimated as a cross product of
estimated stator flux linkage vector and measured motor current vector. The estimated flux magnitude and
torque are then compared with their reference values. If either the estimated flux or torque deviates from
the reference more than allowed tolerance, the transistors of the variable frequency drive are turned off and
on in such a way that the flux and torque will return in their tolerance bands as fast as possible. Thus direct
torque control is one form of the hysteresis or bang-bang control.
Torque and flux can be changed very fast by changing the references
High efficiency & low losses - switching losses are minimized because the transistors are
switched only when it is needed to keep torque and flux within their hysteresis bands
The step response has no overshoot
No coordinate transforms are needed, all calculations are done in stationary coordinate system
No separate modulator is needed, the hysteresis control defines the switch control signals
directly
There are no PI current controllers. Thus no tuning of the control is required
The switching frequency of the transistors is not constant. However, by controlling the width of
the tolerance bands the average switching frequency can be kept roughly at its reference value.
This also keeps the current and torque ripple small. Thus the torque and current ripple are of
the same magnitude than with vector controlled drives with the same switching frequency.
Due to the hysteresis control the switching process is random by nature. Thus there are no
peaks in the current spectrum. This further means that the audible noise of the machine is low
The intermediate DC circuit's voltage variation is automatically taken into account in the
algorithm (in voltage integration). Thus no problems exist due to dc voltage ripple (aliasing) or
dc voltage transients
Synchronization to rotating machine is straightforward due to the fast control; Just make the
torque reference zero and start the inverter. The flux will be identified by the first current pulse
Digital control equipment has to be very fast in order to be able to prevent the flux and torque
from deviating far from the tolerance bands. Typically the control algorithm has to be
performed with 10 - 30 microseconds or shorter intervals. However, the amount of calculations
required is small due to the simplicity of the algorithm
The current and voltage measuring devices have to be high quality ones without noise and low-
pass filtering, because noise and slow response ruins the hysteresis control
In higher speeds the method is not sensitive to any motor parameters. However, at low speeds
the error in stator resistance used in stator flux estimation becomes critical
The direct torque method performs very well even without speed sensors. However, the flux estimation is
usually based on the integration of the motor phase voltages. Due to the inevitable errors in the voltage
measurement and stator resistance estimate the integrals tend to become erroneous at low speed. Thus it is
not possible to control the motor if the output frequency of the variable frequency drive is zero. However, by
careful design of the control system it is possible to have the minimum frequency in the range 0.5 Hz to 1
Hz that is enough to make possible to start an induction motor with full torque from a standstill situation. A
reversal of the rotation direction is possible too if the speed is passing through the zero range rapidly
enough to prevent excessive flux estimate deviation.
If continuous operation at low speeds including zero frequency operation is required, a speed or position
sensor can be added to the DTC system. With the sensor, high accuracy of the torque and speed control can
be maintained in the whole speed range.
History
Direct torque control was patented by Manfred Depenbrock in U.S. Patent 4,678,248 filed originally on
October 20, 1984 in Germany. He called it "Direct Self-Control" (DSC). However, Isao Takahashi and
Toshihiko Noguchi presented a similar idea only few months later in a Japanese journal. Thus direct torque
control is usually credited to all three gentlemen.
The only difference between DTC and DSC is the shape of the path along which the flux vector is controlled
to follow. In DTC the path is a circle and in DSC it was a hexagon. Today DTC uses hexagon flux path only
when full voltage is required at high speeds.
Since Depenbrock, Takahashi and Noguchi had proposed direct torque control (DTC) for induction machines
in the mid 1980s, this new torque control scheme has gained much momentum. From its introduction, the
Direct Torque control or Direct Self Control (DSC) principle has been used for Induction Motor (IM) drives
with fast dynamics. Despite its simplicity, DTC is able to produce very fast torque and flux control, if the
torque and flux are correctly estimated.
Among the others, DTC/DSC was further studied in Ruhr-University in Bochum, Germany at the end of 80's.
A very good treatment of the subject can be found from the doctoral thesis:
Uve Baader: Die Direkte-Selbstregelung (DSR), Ein Verfahren zur hochdynamischen Regelung
von Drehfeldmaschinen. Fortschr.-Ber. VDI Reihe 21, Nr. 35. VDI-Verlag 1988. ISBN 3-18-143521-
X
The first commercial application was in traction. At the end of 80's DSC was tried in German diesel-electric
locomotives DE502 [1][2] and DE1003 [3] by ABB, please see paper:
Jänecke, M., Kremer, R., Steuerwald, G.: Direct Self-Control (DSC), A Novel Method Of
Controlling Asynchronous Machines In Traction Applications. Proceedings of EPE 1989, October
9–12, 1989 Aachen, Germany, Vol. 1, pp. 75–81.
The first major commercial application was, however, the ACS600 variable speed drive by ABB that saw the
daylight in 1995. ACS600 has later been replaced with ACS800 [4]. A good presentation of ACS600 and a
full theoretical treatment of direct torque control can be found in the book:
Peter Vas: Sensorless Vector and Direct Torque Control, Oxford University Press, 1998, ISBN 0-
19-856465-1
Tiitinen, P., Pohjalainen, P., Lalu, J.: The Next Generation Motor Control Method: Direct Torque
Control (DTC). EPE Journal, Vol. 5., no 1, March 1995, pp. 14–18 [5].
Nash, J.: Direct Torque Control, Induction Motor Vector Control Without an Encoder. IEEE Tr. on
Industry Applications, Vol. 33, No. 2, March/April 1997 [6].
DTC has also been applied to three-phase grid side converter control (U.S. Patent 5,940,286). Grid side
converter is identical in structure to the transistor inverter controlling the machine. Thus it can in addition to
rectifying AC to DC also feed back energy from the DC to the AC grid. Further, the waveform of the phase
currents is very sinusoidal and power factor can be adjusted as desired. In the grid side converter DTC
version the grid is considered to be a big electric machine (which, actually, there are many in the grid!). A
paper dealing with grid side converter DTC was presented already in 1995:
Manninen, V.: Application of Direct Torque Control Modulation to a Line Converter. Proc. of EPE
1995, Sept. 19-21, 1995, Sevilla, Spain, Proceedings pp. 1.292-1.296.
In the late 1990s DTC techniques for the Interior Permanent Magnet Synchronous Machine (IPMSM)
appeared.
Further, in the beginning of 2000's DTC was applied to doubly fed machine control (U.S. Patent 6,448,735).
Doubly fed generators are today commonly used in wind turbine applications.
Thinking of the outstanding torque control dynamics of the DTC it was somewhat surprising that the first
servo drive using DTC, ABB's ACSM1,[7] was introduced quite late, in 2007.
During 2000's several papers have been published about DTC. Also several modifications such as space
vector modulated DTC that has constant switching frequency, has been presented.
Due to the expiring of the DTC patent by Depenbrock in 2004 it is to be expected that other companies than
ABB will also start to sell drives using DTC.
Torque and speed of a DC motor
The torque of an electric motor is not necessarily dependent on its speed. It is rather a function of flux and
armature current.
Effects
Increase in flux decreases the speed but increases the torque. If torque is decreased by decreasing the field
current, the following sequences are found:
1. Back EMF drops instantly, the speed remaining constant because of the inertia of heavy
armature.
2. Due to decrease of EMF armature current I is increased because of I = (V − E)/R.
3. A small decrease of flux is more than counterbalanced by a large increase of I which means net
increase of torque.
4. If torque increases the speed also increases.
If applied voltage is kept constant, motor speed has inverse relation with flux.
where:
Characteristics of DC motors
DC motors respond to load changes in different ways, depending on the arrangement of the windings.
A shunt wound motor has a high-resistance field winding connected in parallel with the armature. It
responds to increased load by trying to maintain its speed and this leads to an increase in armature current.
This makes it unsuitable for widely-varying loads, which may lead to overheating.
A series wound motor has a low-resistance field winding connected in series with the armature. It responds
to increased load by slowing down and this reduces the armature current and minimises the risk of
overheating. Series wound motors were widely used as traction motors in rail transport of every kind, but
are being phased out in favour of AC induction motors supplied through solid state inverters. The counter-
EMF aids the armature resistance to limit the current through the armature. When power is first applied to a
motor, the armature does not rotate. At that instant, the counter-EMF is zero and the only factor limiting the
armature current is the armature resistance. Usually the armature resistance of a motor is less than 1 Ω;
therefore the current through the armature would be very large when the power is applied. Therefore the
need arises for an additional resistance in series with the armature to limit the current until the motor
rotation can build up the counter-EMF. As the motor rotation builds up, the resistance is gradually cut out.
A permanent magnet DC motor is characterized by its locked rotor (stall) torque and its no-load angular
velocity (speed).
Thyristor drive
A thyristor drive is a motor drive circuit where AC supply current is regulated by a thyristor phase control
to provide variable voltage to a DC motor.
Applications
Thyristor drives are very simple and were first introduced in the 1960s. They remained the predominant
type of industrial motor controller until the end of the 1980s when the availability of low cost electronics led
to their replacement by chopper drives for high performance systems and inverters for high reliability with
AC motors.
They are still employed in very high power applications, such as locomotives, where the high power
capability of the thyristors and the simplicity of the design can make them a more attractive proposition
than transistor based controllers.
A derivative of the thyristor drive is the simple AC phase controller. This uses a single phase controlled triac
to provide a variable voltage AC output for regulating a universal motor. This is the type of motor speed
control most commonly used in domestic appliances, such as food mixers, and small AC powered tools, such
as electric drills.
Fire-resistance rating
A fire-resistance rating typically means the duration for which a passive fire protection system can
withstand a standard fire resistance test. This can be quantified simply as a measure of time, or it may
entail a host of other criteria, involving other evidence of functionality or fitness for purpose. Common rating
systems
The following depict the most commonly used international time/temperature curves:
There are many international variations for nearly countless types of products and systems, some with
multiple test requirements.
Canada's Institute for Research in Construction (a part of the National Research Council and publisher of
Canada's model building code - NBC) requires a special test regime for firestops for plastic pipe penetrants.
Fire endurance tests for this application must be run under 50Pa positive furnace pressure in order to
adequately simulate the effect of potential temperature differences between indoor and outdoor
temperatures in Canada's winters. Special hoods are applied here to provide suction on the top side of a test
assembly in order to reach the 50Pa pressure differential. Afterwards, a 30PSI hose-stream test may be
applied.
Some fire doors in the North American Free Trade Agreement (NAFTA) area may even open up somewhat
during a fire endurance test, although not too far, while a wall or floor assembly proper may not even be
allowed an average temperature rise above 140°C or single point increases over 180°C.
Outdoor spray fireproofing methods that must be qualified to the hydrocarbon curve may be required to
pass a host of environmental tests before any burn takes place, to minimise the likelihood that ordinary
operational environments cannot render a vital system component useless before it ever encounters a fire.
If critical environmental conditions are not satisfied, an assembly may not be eligible for a fire-resistance
rating.
Regardless of the complexity of any given test regime that may lead to a rating, the premise is generally
product certification and, most importantly listing and approval use and compliance. Testing without
certification and installations that cannot be matched with an appropriate certification listing, are not usually
recognised by any Authority Having Jurisdiction (AHJ) unless it is in a realm where product certification is
optional.
Tests for fire resistance of record protection
equipment
The following classifications may be attained when testing in accordance with UL 72.
This rating is the requirement in data safes and vault structures for protecting digital information on
magnetic media or hard drives. Temperatures inside the protected chamber must be held below 125°F
(51.7°C) for the time period specified, such as Class 125-2 Hour, with temperatures up to 2,000°F
(1,093.3°C) outside the vault. The temperature reading is taken on the inside surfaces of the protective
structure. Maintaining the temperature below 125°F. is critical because data is lost above that temperature
threshold, even if the media or hard drives appear to be intact.
This is the rating required to protect microfilm, microfiche, and other film-based information storage media.
Above 150°F (65.5°C) film is distorted by the heat and information is lost. A Class 150-2 Hour vault must
keep the temperature below 150°F. for at least two hours, with temperatures up to 2,000°F. (1,093.3°C)
outside the vault.
This rating is the requirement for protecting paper documents. Above 350°F (176.7°C) paper is distorted by
the heat and information is lost. A Class 350-4 Hour vault must keep the temperature below 350°F. for at
least four hours, with temperatures up to 2,000°F. (1,093.3°C) outside the vault.
Big differences between different countries in terms of the use of the curves include the use of pipes, which
shield the furnace thermocouples inside of NAFTA testing laboratories. This slows down the response time
and results in a somewhat more conservative test regime in North America. On the other hand, the ISO
based European curves run somewhat hotter for most of the test. North America also selectively uses a
hose-stream test between 30 and 45PSI, to simulate real-world impacts and damages that may not be
simulated in a laboratory. The US Navy even insists on a 90PSI hose-stream test for some of its assemblies,
which may simulate the pressure available to firefighters in fighting a fire, but which has little to do with
countermeasures against damaging effects of manual fire suppression. The hose-stream is simply intended
to add a level of toughness to matters because without this, some fairly flimsy systems can pass a test, thus
receive a rating and thus be permissible by a building code but be so weak that ordinary building use may
damage a thus qualified system before it encounters a fire. See firestop.org treatise on the hose stream
test.
Germany's DIN4102 also includes a significant impact test for a potential firewall, which is, however, applied
from the wrong side: the cold side. Applying the impact from the cold side is more practical to do in a lab
setting, however, potential impacts should come from the exposed side, not the unexposed side. Still, for
the person designing, building and paying for the test, the fire resistance itself may be rather uneventful
unless major problems appear. The burn itself is the long duration, up to 4 hours, but the hose stream test
only lasts a few minutes, with large damage potential due to the sudden thermal and kinetic impacts, as the
fire was upwards of 1,100°C (see curves above), whereas the sudden hose-stream test is as cold as the
domestic water fed to the fire hose used in the test, which might be 10-20°C. This combined impact explains
the debris that can be seen coming from test specimens during the hose stream test, as seen herein.
Because of the large differences in test regimes all over the world, even for identical products and systems,
organizations that intend to market their products internationally are often required to run many tests in
many countries. Even where test regimes are identical, countries are often reluctant to accept the test
results and particularly the certification methods of other countries.
During a fire in a tunnel, as well as in the petrochemical industry, temperatures exceed those of ordinary
building (cellulosic) fires. This is because the fuel for the fire is hydrocarbons, which burn hotter (compare
hydrocarbon curve above to ASTM E119 curve), faster and typically run out of fuel faster as well, compared
against timber. The added complication with tunnels is that the environment inside a "tube" is best
described as a "microclimate". The heat cannot escape as well as it can in a burning refinery, which is in the
open. Instead, the fire is confined to a narrow tube, where pressure and heat build up and spread rapidly,
with little room for escape and little chance of compartmentalization. This scenario was amply tested and
quantified, particularly during the "Eureka Project", run by Technische Universität Braunschweig's iBMB, Dr.
Ekkehard Richter, which has profoundly affected tunnel regulations in the Nations that took part in the
project. The Netherlands, through Rijkswaterstaat in particular, mandated an extremely tough standard, the
curve of which is shown in the gallery above.
Picture 1
Construction of a test sample, consisting of a mock-up concrete floor frame, complete with penetrants. The
concrete frame measures approximately 5’ x 9’ x 4― (ca. 1.5m x 2.3m x 10 cm). It has a large hole in the
centre with many mechanical and electrical services traversing. The penetrants extend 1’ (30 cm) into the
furnace and 3’ (91 cm) on the unexposed side. A firestop mortar is being applied here. Notice the
intumescent wrap strip surrounding the fibreglass pipe insulation. When the fire starts, this embedded
intumescent will swell to take up the place of the melting insulation. The test was conducted in accordance
with the Canadian firestop test method ULC[1] S-115 in Scarborough, Ontario.
Picture 2
The completed test sample is being lifted by crane to the test furnace for the fire resistance test. By
contrast, European furnaces can typically allow up to a 1m penetrant depth to reach into the furnaces. North
American panel furnaces are not deep enough to accommodate this more realistic exposure.
Picture 3
After the completed test sample has been seated on a ceramic fibre gasket on the top of the furnace, gas is
let in through perforated pipes at the bottom of the furnace. The ULC technician is now igniting the gas on
each pipe to start the test. Thermocouples are located inside the furnace to make sure the fire resistance
test is run in accordance with the prescribed time/temperature curve. Further thermocouples are located on
the firestop, 1‖ or 25mm away from each penetrant and on each penetrant, 1‖ or 25mm up from the surface
of the firestop. The length of time the test is run and/or however long it takes for fire to penetrate the
firestop determines the F-Rating. The length of time required for a penetrant and/or the sample on average
to exceed an average heat rise above ambient at the start of the test to exceed 140°C or 180°C at any
single location – this determines the duration for the FT Rating (Fire and Temperature). If the hose-stream
test is passed afterwards, the rating can then be expressed as an FTH Rating (Fire, Temperature and Hose-
stream). The lowest of the three determines the overall rating, though it is possible to have a wide variety of
T results, which can vary depending upn how well each such penetrant conducts heat.
Picture 4
At the conclusion of the fire resistance test, the test sample is lifted off the furnace and readied for a hose-
stream test, which is NOT intended to simulate the effects of firefighting. Instead, it is to add a measure of
reality of possible impacts, thermal shock and generally the brutal environment of a real fire, which is hard
to simulate in pristine laboratory conditions. See this. With combustible penetrants like cables or
combustible firestops like silicone foam, it is not entirely unlikely even after two hours of fire to see residual
flaming on the exposed side. For an example, see this picture. This was proven during a highly publicised
fire test at ULC that encased the silicone foam with noncombustible sheathing in an attempt to justify in-situ
installations in US and Canadian nuclear reactor facilities, as per submissions provided to Select Committee
on Ontario Hydro Nuclear Affairs by Pickering, Ontario Regional Councillor Maurice Brenner
Picture 5
The duration and pressure of the hose-stream test are a direct function of the length of the test and the size
of the test sample. The most typical test pressure is 30PSI, though 45PSI may also be used for fire tests of
4 hours duration or longer.
Picture 6
The test can be considered passed if no fire, water and no excessive heat traversed the sample or
penetrants. All results are tabulated and form part of the rating designations, which can be quite complex in
the case of busy firestop tests such as this. For instance, an uninsulated copper pipe may have only a 5
minute T Rating, whereas that same pipe insulated with 2‖ or 50mm of rockwool may achieve a 2 hour T-
Rating. Product certification listings resulting from such successful testing can be used to obtain the
approval and acceptance of installed configurations on the part of the Authority Having Jurisdiction on
construction sites. Listings are considered public knowledge, whereas the test report itself would be a
proprietary item.
] Picture 7
Observations from both sides of the test assembly continue on the next day, once the sample has cooled
down sufficiently. It is also customary to destroy the test sample, for two reasons: to learn from the effects
of the test on the inside of the sample Research and development, as well as for a test laboratory which
would issue a certification listing on the basis of the test to ensure that the listing reflects accurately what
was installed inside the test assembly, in case and changes occurred that were not previously documented.
Firestop
Firestop after fire exposure during fire test in Tulsa, Oklahoma. This was an R & D test leading to a fire-
resistance rating of three hours.
A firestop is a passive fire protection system of various components used to seal openings and joints in fire-
resistance rated wall and/or floor assemblies, based on fire testing and certification listings.
Unprotected openings in fire separations void the fire-resistance ratings of the fire separations that contain
them, allowing spread of fire past the limits of the fire safety plan of the entire building. Firestops are
designed to restore the fire-resistance ratings of rated wall and/or floor assemblies by impeding the spread
of fire through the opening by filling the openings with fire resistant materials.