GES-100 Solar Cell Trainer

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

R

Solar Cell Trainer


GES-100
The GES-100 Solar Cell Trainer is a simple
and self-contained trainer designed for learning
the basic configuration and characteristics of a
solar cell. Through the use of different
irradiations and various load units, students
study the optic-electro conversion of solar cells
and plot the current-voltage characteristic and
charging/discharging curves.

uFeatures
● Self-contained solar cell trainer
● Modular design, easy of setup and storage
● Adjustable solar irradiation and azimuth of simulation sunlight
● DAQ equipped, easy to acquire and save the experimental data

uSolar Cell Modules


4 pcs of Monocrystalline Silicon Solar Cell 6*12 cm
Each of unit solar cells:
● Open Circuit Voltage (Voc): 0.55V
● Short Circuit Current (Isc): 2.3A
● Maximum Load Voltage (Vpm): 0.5V
● Maximum Load Current (Ipm): 2.2A
● Maximum Power (Ppm): 1.1W
● Efficiency (Eff): 15%

} Dimmer
For adjusting the brightness of Halogen lamp:
- Input voltage 110VAC or 220VAC
- Output voltage 12V
Light Source:
- Halogen Lamp 12V/50W
- Beam Angle 60°
Simple Solar Power Meter:
- Operating with DAQ
2
- Measuring range 10~1200W/m
GES-100

} Experiment Modules uOptional


Digital Multimeter x2 Solar Power Meter
- DC Voltage: 400mV, 4V, 40V, auto ranging; - Display: 3-1/2-digit LCD, Max Indication 1999
Input Resistance ≥10M Ω 2 2
- Measuring Range: 2000 W/m , 634 Btu/(ft x h)
- AC Voltage: 400mV, 4V, 40V, auto ranging; - Resolution: 0.1 W/m 2, 0.1 Btu/(ft 2 x h)
Input Resistance ≥10M Ω M - Accuracy: ±10 W/m 2, ±3 Btu/(ft 2 x h)
- DC Current: 400 μ A , 400mA, 10A , pushbutton switch select - Sampling Rate: 2 Hz
10A Range: 10A/250V fuse protected
mA/ μ A Ranges: 0.5A/250V fuse protected
uAccessories
- AC Current: 400 μ A, 400mA,10A, pushbutton switch select
AC power cord
10A Range: 10A/250V fuse protected
30 cm Test Lead x 10
mA/ μ A Ranges: 0.5A/250V fuse protected
25% Shading Plate x1, 50% Shading Plate x1
- Resistance: 400 Ω, 4K Ω, 40K Ω, 4M Ω , 40M Ω auto ranging
75% Shading Plate x1, 100% Shading Plate x1
- Diode test: 0~1.5V
- Continuity: Buzzer on for the measured resistance <30 Ω
- Display: 3¾digit LCD, Maximum Indication 3999 uScope of Experiments
1.Measuring the Irradiation of Different Light
Sources
} Energy Storage 2.Solar Cell as an Optic-Electro Converter
Ni-MH Rechargeable Battery 1.2V/80mAh, 3.Solar Cell Diode Characteristics
Ultra Capacitor 10F/2.7V 4.Measuring the Open Circuit Voltage of Solar
Cell Shading Test
} Load
5.Measuring the Short Circuit Current of Solar
DC Motor: 0.5V~6V/10mA
Light Bulb: 1.1V Cell Shading Test
Potentiometer: 100 Ω 10-turn 6.Testing the Open Circuit Voltage and Short
Circuit Current of Solar Cell at Different
Irradiations
} Inverter
7.Testing the Short Circuit Current of Solar Cell
Input Voltage 2VDC, Modified Sine Wave Output
1Vpp/60Hz and Square Wave Output 2Vpp/60Hz at Different Incidence Angles of Irradiation
8.Solar Cells in Series Shading Test
} Power Supply 9.Solar Cells in Parallel Shading Test
Input Voltage 110/220VAC, 10.Measuring the I-V Characteristic Curve of
Output Voltage 9VDC/1A for DMM use only
Solar Cell
} DAQ with Software 11.Measuring Maximum Power Point (MPP) of
Channel 1 and 2: max. input voltage ±5V Solar Cell
Channel 3 and 4: max. input current 1A 12.Simulating the Effect of Daylight from Sunrise
to Sunset on Solar Cell
} PC Requirements 13.Charging Battery and Capacitor with Solar Cell
INTEL CPU P4 or better 14.Discharging Battery and Capacitor
USB port equipped 15.Setting up a Solar Power System
1GB of hard disk space 16.Measuring the Inverter Output
CD-ROM drive
Operating System Windows Vista/XP/2000

K&H MFG. CO., LTD.


5F, No. 8, Sec. 4 Tzu-Chiang Rd., Sanchong District,
New Taipei City 24151, Taiwan R.O.C.
http: //www.kandh.com.tw E-Mail :[email protected]
Tel : 886-2-2286-0700 (Rep.) 886-2-2286-7786
Fax : 886-2-2287-3066, 886-2-2287-9704

You might also like