The document describes Euromold, a European manufacturer of prefabricated cable accessories for medium voltage energy distribution. It provides details on Euromold's ISO 9001 certification, laboratory accreditation, and product compliance with international standards. The document also includes specifications and connecting possibilities for various separable connectors, bushings, and accessories.

Uploaded by

P Srinivasan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
158 views

Interface C Connectors

The document describes Euromold, a European manufacturer of prefabricated cable accessories for medium voltage energy distribution. It provides details on Euromold's ISO 9001 certification, laboratory accreditation, and product compliance with international standards. The document also includes specifications and connecting possibilities for various separable connectors, bushings, and accessories.

Uploaded by

P Srinivasan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 48

a Nexans company

Catalogue 2011
Nexans Network Solutions
Div. Euromold
COMPANY PRESENTATION

EUROMOLD International standards


Euromold is the leading All our products meet the
European specialised designer, International standards like
manufacturer and distributor CENELEC HD 629.1, CENELEC
of prefabricated cable EN 50180, IEC 60137, IEC
accessories for medium voltage 60502-4… or country speci-
energy distribution. Euromold fications. Official certificates,
provides a complete range of CESI, KEMA, ATEX… prove the
accessories for underground conformity of our products.
cables: premoulded EPDM Long duration tests of existing
rubber connectors for cables or new products are con-
and epoxy bushings for tinuously performed in our test
transformers and switchgear, as fields.
well as a large range of cold-
shrinkable terminations and
joints from 12 to 42 kV. Laboratory accreditation
Euromold is also the Since June 2000, Euromold’s
manufacturer of electrical independent ELAB laboratory
components for the high obtained the BELAC
voltage accessories of the accreditation no.144-TEST
Nexans group. conform with the European
standards for laboratories ISO
17025 for electrical testing of
ISO 9001 Certificate low and medium voltage cable
Since 1992, Euromold’s accessories according to the
commitment to quality is international standards HD 623
demonstrated by its ISO 9001 and HD 629.
certification.

While every care is taken to ensure that the information contained


in this publication is correct, no legal responsibility can be accepted
for any inaccuracy. Nexans Network Solutions N.V. - Div. Euromold
reserves the right to alter or modify the characteristics of its products
01/2011

described in this catalogue as standards and technology evolve.

1
SEPARABLE CONNECTORS
AND BUSHINGS
INTERFACE C

Table of contents Interface C


400LB - elbow connector Dimensions according to
430TB - tee connector European CENELEC EN 50180
400TB - tee connector and 50181 (in mm).
434TB - tee connector
440TB - tee connector
300PBM - coupling connector
430TBM-P2/P3 - dual/triple cable arrangement
440PBM - coupling connector
434TBM-P2 - dual cable arrangement
400AR-3 - equipment bushing
400AR-4 - equipment bushing
400AR-5 - equipment bushing
Dia. 56±0.2
400AR-6 - equipment bushing
400SFR-B - equipment bushing Dia. 46±0.2
400A-24B - in-air bushing Dia. 22 min for C1
Dia. 32 nominal for C2
300SA - surge arrester
400PB-XSA - surge arrester M16 x 2 - 6H 0
1.5 -0.5
400TR & 400TR-LB - test rod
400TK-400SW installation tools
Accessories 29
min
Possible arrangements

90±0.2

11
min
01/2011

Dia. 70±0.2

2
Connecting possibilities

BUSHINGS / CONNECTION CONNECTORS /


ACCESSORIES ACCESSORIES

Equipment dead-ending
interface of equipment (K)(M)400DR-B
Dead-end receptacle

(K)(M)400AR-3
Equipment bushing

(K)(M)400AR-4
Equipment bushing
(K)400LB/G
Elbow connector
cable to
(K)(M)400AR-5 equipment
Equipment bushing

(K)(M)400AR-6
Equipment bushing
(K)(M)430TB/G (K)(M)300PBM/G
Tee connector Coupling connector

(K)(M)400SFR-B
Equipment bushing

400A-24B
In-air bushing
(K)(M)434TB/G
Tee connector
cable 300SA
isolation Surge arrester
(K)(M)400SOP-B
Stand-off plug

cable
400GP-B earthing
Earthing plug

tap-off (K)(M)(P)400TB/G (K)(M)440PBM/G


(K)400RTPA 630/250A Tee connector Coupling connector
Reducing tap plug

in-line
junction
(K)(M)400CP-SC
Connecting plug

in-line (K)(M)(P)440TB/G
junction Tee connector
(K)(M)440CP 400PB-XSA
Connecting plug Surge arrester
01/2011

3
400LB
INTERFACE C
ELBOW CONNECTOR

Application Technical characteristics Up to 24 kV - 630 A


Separable elbow connector 
  
designed to connect polymeric jacket provides a total safe to
insulated cable to equipment touch screen which ensures
(transformers, switchgear, safety for personnel.
motors...).     
Also connects cable to cable, tested for AC withstand and 6/10 (12) kV
using the appropriate mating partial discharge prior to 6.35/11 (12) kV
part. leaving the factory. 8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV

Design 205 mm
Separable connector
comprising:
1. Conductive EPDM insert.
2. Conductive EPDM jacket.
3. Insulating EPDM layer
moulded between the insert
and the jacket. 9
4. Type C - 630 A interface 6
as described by CENELEC 4
EN 50180 and 50181. 5
5. Conductor connector (not
included in the standard kit). 1
6. Insulating plug.
7. Cable reducer.
8. Earthing lead. 2
9. Transition contact M10/M16. 330 mm
8
The screen break design 3
enables cable outer sheath
testing without removing or
dismantling the connector.

Specifications and
standards 7
The 400LB separable connector
meets the requirements of
CENELEC HD 629.1.

Separable Voltage Current Conductor sizes (mm2)


connector Um Ir
type (kV) (A) min max
01/2011

400LB/G 12 630 25 300


K400LB/G 24 630 25 300

4
Kit contents
The complete (K)400LB/G The kit also comprises silicone grease, field
elbow connector kit comprises control mastic and installation instructions.

3 x the following components:

3 x (K)400LB/G-W(-X)
connector kit

Transition
contact + Insulating
Connector housing screw assembly plug Cable reducer
(K)400BLB 400LTS 400LBP 411CA-W

Ordering instructions Table W


Select the part number
which gives the best centring Ordering Dia. over core insulation (mm)
to the cable core insulation part number min max
diameter.
3 x 400LB/G-11 12.0 17.5
Add a 'K' for use up to 24 kV.
3 x 400LB/G-15 16.0 22.0
3 x 400LB/G-19 20.0 26.5
3 x 400LB/G-22 23.5 31.0
Example: 3 x 400LB/G-25 26.5 32.5
3 x 400LB/G-27 28.5 37.5
The copper wire screened
cables are 24 kV, 240 mm2
stranded aluminium with a
diameter over core insulation
of 32.2 mm. Dia. 10.2 or 13 Notes:
Order 3 x K400LB/G-27 elbow 10.5
We do not supply the compression
max Dia. 36
connector kit. max lugs in the standard kit. All types
of cable lugs can be used. The
24 max 2 max
lugs must be within the dimensions
specified and the palm of the lug
38 must be copper or any equivalent
max
alloy.
112 max
135 max

For use with For use with Alupe or For use with fabric tape Can be supplied For applications Components can be
copper tape C 33-226 cables. (graphite) screened cables. with cable lugs. outdoors and in ordered individually.
screened cables. Please contact our Order additional humid climate.
Order: Kit MT. representative. semi-conductive tape Order: +MWS.
(type TSC).

5
430TB
INTERFACE C
TEE CONNECTOR

Application Technical characteristics Up to 36 kV


Separable tee shape  
   630 A (800 A)
connector (bolted type) jacket provides a total safe to
designed to connect polymeric touch screen.
insulated cable to equipment       6/10 (12) kV
(transformers, switchgear, tested for AC withstand and 6.35/11 (12) kV
motors, ...). partial discharge prior to 8.7/15 (17.5) kV
Also connects cable to cable leaving the factory. 12/20 (24) kV
when using the appropriate 12.7/22 (24) kV
mating parts. 18/30 (36) kV
19/33 (36) kV

Design 185 mm
Separable connector
comprising:
1. Conductive EPDM insert.
2. Conductive EPDM jacket.
3. Insulating EPDM layer
moulded between the insert
and the jacket.
4. Type C interface as
described by CENELEC
4 9
EN 50180 and 50181. 8
5. Conductor connector.
6. Basic insulating plug (with 5
VD point).
6
7. Cable reducer. 1
8. Conductive rubber cap.
290 mm
9. Clamping screw.
10. Earthing lead. 2
(350 mm
The screen break design for 36 kV)
3
enables cable outer sheath
testing without removing or
dismantling the connector.
10

Specifications and
standards
The 430TB separable connector 7
meets the requirements of
CENELEC HD 629.1.

Separable Voltage Current Current Ir (A)


Conductor sizes (mm2)
When installed on an appropriate equipment
connector Um Ir bushing and when using a copper (-11-2) or a
type (kV) (A) bolted (-12-5 or -14-5) conductor contact min max
430TB/G 12 630 800 35 300
01/2011

K430TB/G 24 630 800 35 300


M430TB/G 36 630 800 50 240

6
Kit contents
The complete (K)(M)430TB/G The kit also comprises silicone grease, field
control mastic, installation rod, installation
tee connector kit comprises 3 x instructions and crimp chart.
the following components:

Conductor
contact TMBC-X
3 x (K)(M)430TB/G-W-X
connector kit

Cable reducer
Basic insulating
430CA-W
Clamping plug
Connector housing screw Conductor (K)(M)300BIPA + (411CA-W
(K)(M)430BT/G 430TCS contact TBC-X rubber cap for 36 kV)

Ordering instructions Table W


To order the tee connector,
select the ordering part number Voltage Dia. over core insulation (mm)
Ordering
which gives you the best (Um)
part number
(kV) min max
centring of your core insula-
tion diameter and substitute X 3 x 430TB/G-11-X 12 12.0 17.5
using table X, according to your 3 x 430TB/G-16-X 12 17.0 23.5
3 x 430TB/G-18-X 12 19.0 32.6
conductor size and type.
3 x K430TB/G-11-X 24 12.0 17.5
3 x K430TB/G-16-X 24 17.0 23.5
Example: 3 x K430TB/G-18-X 24 19.0 32.6
The cable is 24 kV, 150 mm2 3 x M430TB/G-11-X 36 12.0 17.5
compact stranded copper with 3 x M430TB/G-15-X 36 16.0 22.0
a diameter over core insulation 3 x M430TB/G-19-X 36 20.0 26.5
3 x M430TB/G-22-X 36 23.5 31.0
of 27.5 mm. 3 x M430TB/G-25-X 36 26.5 32.5
Order 3 x M430TB/G-27-X 36 28.5 37.5
3 x K430TB/G-18-95.240-14-5
tee connector kit. Table X

Conduc- Aluminium conductor Copper conductor


tor sizes DIN Deep DIN
(mm2) Bolted Bolted
hexagonal indent hexagonal
35 35(K)M-10-2 35KM-10-1 35(K)M-11-2
16.95-14-5

16.95-14-5
50.150-14-5
50 50(K)M-10-2 50(K)M-10-1 50(K)M-11-2
50.150-14-5

70 70(K)M-10-2 70(K)M-10-1 70(K)M-11-2


95 95(K)M-10-2 95(K)M-10-1 95(K)M-11-2
95.240-14-5

95.240-14-5

120 120(K)M-10-2 120(K)M-10-1 120(K)M-11-2


120.300-12-5

120.300-12-5

150 150(K)M-10-2 150(K)M-10-1 150(K)M-11-2


185 185(K)M-10-2 185(K)M-10-1 185(K)M-11-2
240 240(K)M-10-2 240(K)M-10-1 240(K)M-11-2
300 300(K)M-10-2 – 300(K)M-11-2

For use with For use with Alupe or For use with For use with For applications When installed on an
copper tape C 33-226 cables. easy strip semi-conductive other cable types. outdoors and in appropriate equipment
screened cables. Please contact our screened cables. Order: Please contact our humid climate. bushing:
Order: Kit MT. representative. Field control mastic representative. Order: +MWS. 800 A continuously
(type MFC).

7
400TB
INTERFACE C
TEE CONNECTOR

Application Technical characteristics Up to 41.5 kV


Separable tee shape 
   630 A (800 A)
connector (bolted type) jacket provides a total safe to
designed to connect polymeric touch screen which ensures 6/10 (12) kV
insulated cable to equipment safety for personnel. 6.35/11 (12) kV
(transformers, switchgear,      8.7/15 (17.5) kV
motors, ...). tested for AC withstand and 12/20 (24) kV
Also connects cable to cable partial discharge prior to 12.7/22 (24) kV
when using the appropriate leaving the factory. 18/30 (36) kV
mating parts. 19/33 (36) kV
20.8/36 (41.5) kV

255 mm
Design 220 mm
Separable connector
comprising:
1. Conductive EPDM insert.
2. Conductive EPDM jacket.
3. Insulating EPDM layer.
4. Type C - 630 A interface
as described by CENELEC
EN 50180 and 50181. 4 9
5. Conductor connector.
5
6. Basic insulating plug (with 6 8
VD point).
7. Cable reducer. 1
8. Conductive rubber cap.
9. Clamping screw. 2
10. Earthing lead.
350 mm
3
The screen break design
enables cable outer sheath
testing without removing or 10
dismantling the connector.

Specifications and
standards
The 400TB separable connector
meets the requirements of 7
CENELEC HD 629.1 S1.

Separable Voltage Current Current Ir (A)


Conductor sizes (mm2)
When installed on an appropriate equipment
connector Um Ir bushing and when using a copper (-11-2) or a
type (kV) (A) bolted (-12-5 or -14-5) conductor contact min max
400TB/G 12 630 800 35 300
K400TB/G 24 630 800 35 300
01/2011

M400TB/G 36 630 800 35 240


P400TB/G 41.5 630 800 35 240

8
Kit contents
The complete (K)(M)(P)400TB/G The kit also comprises silicone grease, field
tee connector kit comprises the control mastic, installation instructions and
crimp chart.
following components:

Conductor
contact TMBC-X
(K)(M)(P)400TB/G-W-X
connector kit

Basic insulating
Clamping plug
Connector housing screw Conductor (K)(M)(P)400BIPA Cable reducer
(K)(M)(P)400BT/G 400TCS contact TBC-X + rubber cap 411CA-W

Ordering instructions Table W


To order the tee connector,
select the ordering part number Ordering Dia. over core insulation (mm)
which gives you the best part number min max
centring of your core insula- 400TB/G-11-X 12.0 17.5
tion diameter and substitute X 400TB/G-15-X 16.0 22.0
using table X, according to your 400TB/G-19-X 20.0 26.5
conductor size and type. 400TB/G-22-X 23.5 31.0
Add a 'K' for use up to 24 kV, 400TB/G-25-X 26.5 32.5
add an 'M' for use up to 36 kV, 400TB/G-27-X 28.5 37.5
add a 'P' for use up to 41.5 kV.
Table X

Conduc- Aluminium conductor Copper conductor


tor sizes DIN Deep DIN
(mm2) Bolted Bolted
hexagonal indent hexagonal
Example:
35 35(K)M-10-2 35KM-10-1 35(K)M-11-2
16.95-14-5

16.95-14-5
The copper wire screened cable 50.150-14-5
50 50(K)M-10-2 50(K)M-10-1 50(K)M-11-2
is 36 kV, 150 mm2 stranded
50.150-14-5

70 70(K)M-10-2 70(K)M-10-1 70(K)M-11-2


copper with a diameter over 95 95(K)M-10-2 95(K)M-10-1 95(K)M-11-2
95.240-14-5

95.240-14-5

core insulation of 32.5 mm. 120 120(K)M-10-2 120(K)M-10-1 120(K)M-11-2


120.300-12-5

120.300-12-5

Order a M400TB/G-27-150(K) 150 150(K)M-10-2 150(K)M-10-1 150(K)M-11-2


M-11-2 tee connector kit. 185 185(K)M-10-2 185(K)M-10-1 185(K)M-11-2
240 240(K)M-10-2 240(K)M-10-1 240(K)M-11-2
300 300(K)M-10-2 – 300(K)M-11-2

For use with For use with For applications For use in potentially Components can be When installed on an
copper tape other cable types. outdoors and in explosive atmospheres ordered individually. appropriate equipment
screened cables. Please contact our humid climate. (for 12 kV max). bushing:
Order: Kit MT. representative. Order: +MWS. Add -/ATEX to part number. 800 A continuously

9
434TB
INTERFACE C
TEE CONNECTOR

Application Technical characteristics Up to 36 kV


Separable tee shape 
   Up to 1250 A
connector (bolted type) jacket provides a total safe to
designed to connect polymeric touch screen which ensures
insulated cable to equipment safety for personnel.
(transformers, switchgear,
6/10 (12) kV
    
motors, ...). tested for AC withstand and
6.35/11 (12) kV
Also connects cable to cable partial discharge prior to
8.7/15 (17.5) kV
when using the appropriate leaving the factory. 12/20 (24) kV
mating parts. 12.7/22 (24) kV
18/30 (36) kV
19/33 (36) kV

Design 185 mm
Separable connector
comprising:
1. Conductive EPDM insert.
2. Conductive EPDM jacket.
3. Insulating EPDM layer
moulded between the insert
and the jacket.
4. Type C interface as
4 9
described by CENELEC
EN 50180 and 50181. 8
5
5. Conductor connector.
6. Basic insulating plug (with 6
1
VD point).
7. Cable reducer.
2
8. Conductive rubber cap.
9. Clamping screw.
355 mm 3
10. Earthing lead.
The screen break design
enables cable outer sheath
testing without removing or 10
dismantling the connector.

Specifications and
standards
The 434TB separable connector
meets the test requirements of 7
CENELEC HD 629.1.

Current Conductor sizes (mm2)


Separable Voltage
Ir (A) Cable with reduced Cable with unreduced
connector Um
When installed on an core insulation thickness core insulation thickness
type (kV)
appropriate equipment bushing
min max min max
434TB/G 12 up to 1250 185 800 185 800
01/2011

K434TB/G 24 up to 1250 185 800 185 800


M434TB/G 36 up to 1250 185 800 185 630

10
Kit contents
The complete (K)(M)434TB/G The kit also comprises silicone grease, field
tee connector kit comprises the control mastic, installation instructions and
crimp chart.
following components:

Conductor
contact TMBC-X
(K)(M)434TB/G-W-X
connector kit

Basic insulating
Clamping plug
Connector housing screw Conductor (K)(M)300BIPA + Cable reducer
(K)(M)434BT/G 430TCS contact TBC-X rubber cap 611CA-W

Ordering instructions Table W


To order the tee connector,
select the ordering part number Ordering Dia. over core insulation (mm)
which gives you the best part number min max
centring of your core insula- 434TB/G-22-X 23.5 31.0
tion diameter and substitute X 434TB/G-27-X 28.5 37.5
using table X, according to your 434TB/G-32-X 34.0 42.5
conductor size and type. 434TB/G-37-X 39.0 48.5
Add a 'K' for use up to 24 kV, 434TB/G-43-X 45.5 56.0
add an 'M' for use up to 36 kV.
Table X
Example:
Conduc- Aluminium conductor Copper conductor
The copper wire screened cable
tor sizes DIN Deep DIN
is 36 kV, 240 mm2 stranded (mm2) Bolted Bolted
hexagonal indent hexagonal
aluminium with a diameter over
core insulation of 37.0 mm. 185 185(K)M-12-2 185(K)M-12-1 185(K)M-11-2
Order a M434TB/G-32-
240 240(K)M-12-2 240(K)M-12-1 240(K)M-11-2
240(K)M-12-2 tee connector kit.
300 300(K)M-12-2 300(K)M-12-1 300(K)M-11-2

400.630-
400 400(K)M-12-2 400(K)M-12-1 400(K)M-11-2
14-5

500 500(K)M-12-2 500(K)M-12-1 500(K)M-11-2

630 630(K)M-12-2 630(K)M-12-1 630(K)M-11-2 –

800 800(K)M-12-2 800(K)M-12-1 – 800(K)M-11-2 –

For use with For use with For use with Alupe or For applications Components can be When installed on an
copper tape other cable types. C 33-226 cables. outdoors and in ordered individually. appropriate equipment
screened cables. Please contact our Please contact our humid climate. bushing:
Order: Kit MT. representative. representative. Order: +MWS. 1250 A continuously

11
440TB
INTERFACE C
TEE CONNECTOR

Application Technical characteristics Up to 41.5 kV


Separable tee shape 
   630 A (1250 A)
connector (bolted type) jacket provides a total safe to
designed to connect polymeric touch screen which ensures 6/10 (12) kV
insulated cable to equipment safety for personnel. 6.35/11 (12) kV
(transformers, switchgear,      8.7/15 (17.5) kV
motors, ...). tested for AC withstand and 12/20 (24) kV
Also connects cable to cable partial discharge prior to 12.7/22 (24) kV
when using the appropriate leaving the factory. 18/30 (36) kV
mating parts. 19/33 (36) kV
20.8/36 (41.5) kV

Design 255 mm
Separable connector 220 mm
comprising:
1. Conductive EPDM insert.
2. Conductive EPDM jacket.
3. Insulating EPDM layer
moulded between the insert
and the jacket.
4. Type C - 630 A interface
4 9
as described by CENELEC
EN 50180 and 50181.
5. Conductor connector. 5 6 8
6. Basic insulating plug (with
VD point). 1
7. Cable reducer.
8. Conductive rubber cap. 2
9. Clamping screw.
10. Earthing lead. 355 mm 3

The screen break design


enables cable outer sheath
testing without removing or 10
dismantling the connector.

Specifications and
standards
The 440TB separable connector 7
meets the requirements of
CENELEC HD 629.1.

Separable Voltage Current Current


Conductor sizes (mm2)
connector Um Ir Ir (A)
When installed on an
type (kV) (A) appropriate equipment bushing min max
440TB/G 12 630 1250 185 630
K440TB/G 24 630 1250 185 630
01/2011

M440TB/G 36 630 1250 185 630


P440TB/G 41.5 630 1250 185 630

12
Kit contents
The complete (K)(M)(P)440TB/G The kit also comprises silicone grease, field
tee connector kit comprises the control mastic, installation instructions and
crimp chart.
following components:

Conductor
contact TMBC-X
(K)(M)(P)440TB/G-W-X
connector kit

Basic insulating
Clamping plug
Connector housing screw Conductor (K)(M)(P)400BIPA Cable reducer
(K)(M)(P)440BT/G 430TCS contact TBC-X + rubber cap 611CA-W

Ordering instructions Table W


To order the tee connector,
select the ordering part number Ordering Dia. over core insulation (mm)
which gives you the best part number min max
centring of your core insula- 440TB/G-22-X 23.5 31.0
tion diameter and substitute X 440TB/G-27-X 28.5 37.5
using table X, according to your 440TB/G-32-X 34.0 42.5
conductor size and type. 440TB/G-37-X 39.0 48.5
Add a 'K' for use up to 24 kV, 440TB/G-43-X 45.5 56.0
add an 'M' for use up to 36 kV,
add a 'P' for use up to 41.5 kV. Table X

Conduc- Aluminium conductor Copper conductor


Example:
tor sizes DIN Deep DIN
The copper wire screened cable (mm2) Bolted Bolted
hexagonal indent hexagonal
is 36 kV, 240 mm2 stranded
aluminium with a diameter over 185 185(K)M-12-2 185KM-12-1 185(K)M-11-2
core insulation of 37.0 mm. 240 240(K)M-12-2 240KM-12-1 240(K)M-11-2
Order a M440TB/G-32-240(K)
M-12-2 tee connector kit. 300 300(K)M-12-2 300KM-12-1 300(K)M-11-2
400.630-

400 400(K)M-12-2 400KM-12-1 400(K)M-11-2


14-5

500 500(K)M-12-2 500KM-12-1 500(K)M-11-2

630 – 630KM-12-1 630(K)M-11-2

For use with For use with For applications For use in potentially Components can be When installed on an
copper tape other cable types. outdoors and in explosive atmospheres ordered individually. appropriate equipment
screened cables. Please contact our humid climate. (for 12 kV max). bushing:
Order: Kit MT. representative. Order: +MWS. Add -/ATEX to part number. 1250 A continuously

13
300PBM
COUPLING CONNECTOR
FOR 430TB/G

Application Technical characteristics Up to 36 kV


Separable coupling connector  
   630 A (1250 A)
(bolted type) for dual cable jacket provides a total safe to
arrangement. It has been touch screen.
designed to be used with      6/10 (12) kV
430TB separable Tee connector. tested for AC withstand and 6.35/11 (12) kV
partial discharge prior to 8.7/15 (17.5) kV
leaving the factory. 12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV
19/33 (36) kV

290 mm
Design
1. Interface designed to fit
430TB connector.
2. Bus for 300PBM.
3. Conductive EPDM insert.
4. Insulating EPDM layer
moulded between the
insert and the jacket.
5. Conductive EPDM jacket. 2
6. Conductive EPDM cap. 6
7. Basic insulating plug (with 1
8 7
VD point).
8. Conductor connector 3
(hexagonal crimping, deep
indent crimping or bolted). 290 mm
9. Cable reducer. (350 mm
10. Earthing lead. for 36 kV) 4
300PBM
The screen break design 430TB coupling
5
enables cable outer sheath connector connector
testing without removing or
dismantling the connector.
10
9
Specifications and
standards
The 300PBM coupling
connector meets the
requirements of CENELEC
HD 629.1. 105 mm

Separable Voltage Current Current Ir (A)


Conductor sizes (mm2)
When installed on an appropriate equipment
connector Um Ir bushing and when using a copper (-11-2) or a
type (kV) (A) bolted (-12-5 or -14-5) conductor contact min max
300PBM/G 12 630 1250 35 300
01/2011

K300PBM/G 24 630 1250 35 300


M300PBM/G 36 630 1250 50 240

14
Kit contents
The complete (K)(M)300PBM/G The kit also comprises silicone grease, field
coupling connector kit control mastic, installation rod, installation
instructions and crimp chart.
comprises 3 x the following
components:

Conductor
contact TMBC-X
3 x (K)(M)300PBM/G-W-X
coupling connector kit

Cable reducer
430CA-W
Connector housing Contact rod Conductor (411CA-W
(K)(M)300BP/G 300PB-CR contact TBC-X for 36 kV)

Ordering instructions Table W


To order the coupling connector,
select the ordering part number Voltage Dia. over core insulation (mm)
Ordering
which gives you the best (Um)
part number
(kV) min max
centring of your core insula-
tion diameter and substitute X 3 x 300PBM/G-11-X 12 12.0 17.5
using table X, according to your 3 x 300PBM/G-16-X 12 17.0 23.5
3 x 300PBM/G-18-X 12 19.0 32.6
conductor size and type.
3 x K300PBM/G-11-X 24 12.0 17.5
3 x K300PBM/G-16-X 24 17.0 23.5
Example: 3 x K300PBM/G-18-X 24 19.0 32.6
The cable is 24 kV, 150 mm2 3 x M300PBM/G-11-X 36 12.0 17.5
compact stranded copper with 3 x M300PBM/G-15-X 36 16.0 22.0
a diameter over core insulation 3 x M300PBM/G-19-X 36 20.0 26.5
3 x M300PBM/G-22-X 36 23.5 31.0
of 27.5 mm. 3 x M300PBM/G-25-X 36 26.5 32.5
Order 3 x 3 x M300PBM/G-27-X 36 28.5 37.5
K300PBM/G-18-95.240-14-5
coupling connector kit. Table X

Conduc- Aluminium conductor Copper conductor


tor sizes DIN Deep DIN
(mm2) Bolted Bolted
hexagonal indent hexagonal
35 35(K)M-10-2 35KM-10-1 35(K)M-11-2
16.95-14-5

16.95-14-5
50.150-14-5
50 50(K)M-10-2 50(K)M-10-1 50(K)M-11-2
50.150-14-5

70 70(K)M-10-2 70(K)M-10-1 70(K)M-11-2


95 95(K)M-10-2 95(K)M-10-1 95(K)M-11-2
95.240-14-5

95.240-14-5

120 120(K)M-10-2 120(K)M-10-1 120(K)M-11-2


120.300-12-5

120.300-12-5

150 150(K)M-10-2 150(K)M-10-1 150(K)M-11-2


185 185(K)M-10-2 185(K)M-10-1 185(K)M-11-2
240 240(K)M-10-2 240(K)M-10-1 240(K)M-11-2
300 300(K)M-10-2 – 300(K)M-11-2

For use with For use with fabric tape For use with For use with copper For use with For outdoor
copper tape (graphite) screened cables. easy strip semi-conductive wire screened cables. other cable types. applications.
screened cables. Order additional screened cables. Order: No earthing Please contact our Order: +MWS.
Order: Kit MT. semi-conductive tape Field control mastic device is representative.
(type TSC). (type MFC). necessary.

15
430TBM-P2/P3
DUAL/TRIPLE CABLE ARRANGEMENT
FOR 430TB CONNECTOR
Application Technical characteristics Up to 36 kV
Separable connectors (bolted  
   630 A (1250 A)
type) for dual (P2) and triple jacket provides a total safe to
(P3) cable arrangements. touch screen.
     6/10 (12) kV
tested for AC withstand and 6.35/11 (12) kV
partial discharge prior to 8.7/15 (17.5) kV
leaving the factory. 12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV
19/33 (36) kV

Design 290 mm
1. Type C interface as
described by CENELEC
EN 50180 and 50181.
2. Bus for 300PBM.
3. Conductive EPDM insert.
4. Insulating EPDM layer
moulded between the
insert and the jacket. 2
1
5. Conductive EPDM jacket. 6
6. Conductive EPDM cap. 8
7. Basic insulating plug (with Non-size 7
sensitive: 3
VD point).
290 mm
8. Conductor connector.
9. Cable reducer. Size
10. Earthing lead. sensitive:
350 mm 4
The screen break design 300PBM
430TBM coupling
enables cable outer sheath connector 5 connector
testing without removing or
dismantling the connector.
10
Specifications and
standards 9
The 430TBM-P2/P3 connectors
meet the requirements of
CENELEC HD 629.1.
105 mm

Separable Voltage Current Current Ir (A)


Conductor sizes (mm2)
When installed on an appropriate equipment
connector Um Ir bushing and when using a copper (-11-2) or a
type (kV) (A) bolted (-12-5 or -14-5) conductor contact min max
430TBM-P2/P3 12 630 1250 35 300
01/2011

K430TBM-P2/P3 24 630 1250 35 300


M430TBM-P2/P3 36 630 1250 50 240

16
Kit contents
The complete (K)(M)430TBM-P2 The complete (K)(M)430TBM-P3
connector kit comprises 3 x the connector kit comprises 3 x the
following components: following components:
290

300BIPA
300BIPA basic
basic insulating
insulating plug
plug
300PBM
300PBM
coupling
coupling
connectors
connector

430TB tee
connector 430TB tee
connector

110 105
In mm.

Ordering instructions 1. From table W: select the Table W


To order the separable symbol which gives the best
connectors for dual cable centring of your core insulation Dia. over core
arrangement, use the tables insulation (mm) W
diameter.
beside to substitute for W and min max
2. From table X: according to
X in the formula: 12.0 17.5 11
3 x 430TBM-P2-W-X, your conductor size and type,
select the designation which 16.0 22.0 15
for use up to 12 kV.
Add a 'K' for use up to 24 kV: 20.0 26.5 19
completes the part number.
3 x K430TBM-P2-W-X. 23.5 31.0 22
Add an 'M' for use up to 36 kV: 26.5 32.5 25
3 x M430TBM-P2-W-X. 28.5 37.5 27

For triple cable arrangement: Table X


3 x 430TBM-P3-W-X,
for use up to 12 kV. Conduc- Aluminium conductor Copper conductor
Add a 'K' for use up to 24 kV: tor sizes DIN Deep DIN
3 x K430TBM-P3-W-X. (mm2) Bolted Bolted
hexagonal indent hexagonal
Add an 'M' for use up to 36 kV: 35 35(K)M-10-2 35KM-10-1 35(K)M-11-2
16.95-14-5

16.95-14-5
3 x M430TBM-P3-W-X. 50.150-14-5
50 50(K)M-10-2 50(K)M-10-1 50(K)M-11-2
50.150-14-5

70 70(K)M-10-2 70(K)M-10-1 70(K)M-11-2


Example:
95 95(K)M-10-2 95(K)M-10-1 95(K)M-11-2
The two cables are 24 kV,
95.240-14-5

95.240-14-5

150 mm2 stranded aluminium 120 120(K)M-10-2 120(K)M-10-1 120(K)M-11-2


120.300-12-5

120.300-12-5

with a diameter over core 150 150(K)M-10-2 150(K)M-10-1 150(K)M-11-2


insulation of 27.5 mm. 185 185(K)M-10-2 185(K)M-10-1 185(K)M-11-2
Order 3 x K430TBM-P2-22- 240 240(K)M-10-2 240(K)M-10-1 240(K)M-11-2
150(K)M-10-2. 300 300(K)M-10-2 – 300(K)M-11-2

For use with For use with Alupe or For use with For use with For applications When installed on an
copper tape C 33-226 cables. other cable types. easy strip semi-conductive outdoors and in appropriate equipment
screened cables. Please contact our Please contact our screened cables. Order: humid climate. bushing:
Order: Kit MT. representative. representative. Field control mastic Order: +MWS. 1250 A continuously
(type MFC).

17
440PBM
COUPLING CONNECTOR
FOR 440TB

Application Technical characteristics Up to 36 kV


Separable coupling connector  
   630 A (1250 A)
(bolted type) for dual cable jacket provides a total safe to
arrangement. It has been touch screen.
designed to be used with     
440TB separable Tee connector. tested for AC withstand and 6/10 (12) kV
partial discharge prior to 6.35/11 (12) kV
leaving the factory. 8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV

Design
1. Interface designed to fit
440TB connector. 410 mm
2. Bus for 440PBM.
3. Conductive EPDM insert.
4. Insulating EPDM layer
moulded between the
insert and the jacket.
5. Conductive EPDM jacket. 2
6. Conductive EPDM cap. 6
1 8
7. Basic insulating plug. 7
8. Conductor connector 3
440TB 440PBM
(hexagonal crimping, deep connector coupling
4
indent crimping or bolted). connector
400 mm
9. Cable reducer. 5
10. Earthing lead.

The screen break design


enables cable outer sheath 10
testing without removing or
dismantling the connector.
9

Specifications and
standards
The 440PBM coupling 155 mm
connector meets the
requirements of CENELEC
HD 629.1.

Separable Voltage Current Current


Conductor sizes (mm2)
connector Um Ir Ir (A)
When installed on an
type (kV) (A) appropriate equipment bushing min max
440PBM/G 12 630 1250 185 630
01/2011

K440PBM/G 24 630 1250 185 630


M440PBM/G 36 630 1250 185 630

18
Kit contents
The complete The kit also comprises silicone grease, field
(K)(M)440PBM/G coupling control mastic, installation rod, installation
instructions and crimp chart.
connector kit comprises 3 x the
following components:

Conductor
contact TMBC-X
3 x (K)(M)440PBM/G-W-X
coupling connector kit

Contact rod
Connector housing 440PB-CR Conductor Cable reducer
(K)(M)440BP/G + M16 stud contact TBC-X 611CA-W

Ordering instructions Table W


To order the coupling connector,
select the ordering part number Ordering Dia. over core insulation (mm)
which gives you the best part number min max
centring of your core insula- 3 x 440PBM/G-22-X 23.5 31.0
tion diameter and substitute X 3 x 440PBM/G-27-X 28.5 37.5
using table X, according to your 3 x 440PBM/G-32-X 34.0 42.5
conductor size and type. 3 x 440PBM/G-37-X 39.0 48.5
Add a 'K' for use up to 24 kV, 3 x 440PBM/G-43-X 45.5 56.0
add an 'M' for use up to 36 kV.
Table X
Example:
Conduc- Aluminium conductor Copper conductor
The copper wire screened cable
tor sizes DIN Deep DIN
is 36 kV, 240 mm2 stranded (mm2) Bolted Bolted
hexagonal indent hexagonal
aluminium with a diameter over
core insulation of 37.0 mm. 185 185(K)M-12-2 185KM-12-1 185(K)M-11-2
Order 3 x M440PBM/G- 240 240(K)M-12-2 240KM-12-1 240(K)M-11-2
32-240(K)M-12-2 coupling
connector kit. 300 300(K)M-12-2 300KM-12-1 300(K)M-11-2
400.630-

400 400(K)M-12-2 400KM-12-1 400(K)M-11-2


14-5

500 500(K)M-12-2 500KM-12-1 500(K)M-11-2

630 – 630KM-12-1 630(K)M-11-2

For use with For use with fabric tape For use with For use with copper For use with For outdoor
copper tape (graphite) screened cables. easy strip semi-conductive wire screened cables. other cable types. applications.
screened cables. Order additional screened cables. Order: No earthing Please contact our Order: +MWS.
Order: Kit MT. semi-conductive tape Field control mastic device is representative.
(type TSC). (type MFC). necessary.

19
434TBM-P2
DUAL CABLE ARRANGEMENT FOR
434TB CONNECTOR

Application Technical characteristics Up to 36 kV


Separable connectors (bolted  
   630 A (1250 A)
type) for dual cable jacket provides a total safe to
arrangements. touch screen.
    
tested for AC withstand and 6/10 (12) kV
partial discharge prior to 6.35/11 (12) kV
leaving the factory. 8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV

Design 345 mm
1. Type C interface as
described by CENELEC
EN 50180 and 50181.
2. Bus for 440PB.
3. Conductive EPDM insert.
4. Insulating EPDM layer 11 2
moulded between the
1 6
insert and the jacket. 8
5. Conductive EPDM jacket.
6. Conductive EPDM cap. 3 7
440PB
7. Basic insulating plug (with coupling
VD point). connector 4
8. Conductor connector. 434TB
5 connector
9. Cable reducer.
10. Earthing lead.
11. Threaded M16 stud for the
equipment bushing.
10
The screen break design
enables cable outer sheath
testing without removing or
dismantling the connector. 9

Specifications and
standards 155 mm
The 434TBM-P2 connectors
meet the requirements of
CENELEC HD 629.1.

Separable Voltage Current Current Ir (A)


Conductor sizes (mm2)
When installed on an appropriate equipment
connector Um Ir bushing and when using a copper (-11-2) or a
type (kV) (A) bolted (-12-5 or -14-5) conductor contact min max
434TBM-P2 12 630 1250 185 630
01/2011

K434TBM-P2 24 630 1250 185 630


M434TBM-P2 36 630 1250 185 630

20
Kit contents
The complete (K)(M)434TBM-P2
connector kit comprises 3 x the
following components:

345

300BIPA
basic
insulating
plug

434TB
tee
connector

440PB
coupling
connector

110 155
In mm.

Ordering instructions Table W


To order the coupling connector,
select the ordering part number Ordering Dia. over core insulation (mm)
which gives you the best part number min max
centring of your core insula- 3 x 434TBM-P2-22-X 23.5 31.0
tion diameter and substitute X 3 x 434TBM-P2-27-X 28.5 37.5
using table X, according to your 3 x 434TBM-P2-32-X 34.0 42.5
conductor size and type. 3 x 434TBM-P2-37-X 39.0 48.5
Add a 'K' for use up to 24 kV, 3 x 434TBM-P2-43-X 45.5 56.0
add an 'M' for use up to 36 kV.
Table X
Example:
The copper wire screened cable Conduc- Aluminium conductor Copper conductor
tor sizes
is 36 kV, 240 mm2 stranded DIN Deep
Bolted
DIN
Bolted
(mm2) hexagonal indent hexagonal
aluminium with a diameter over
core insulation of 37.0 mm. 185 185(K)M-12-2 185KM-12-1 185(K)M-11-2
Order 3 x M434TBM-P2-
240 240(K)M-12-2 240KM-12-1 240(K)M-11-2
32-240(K)M-12-2 coupling
connector kit. 300 300(K)M-12-2 300KM-12-1 300(K)M-11-2
400.630-

400 400(K)M-12-2 400KM-12-1 400(K)M-11-2


14-5

500 500(K)M-12-2 500KM-12-1 500(K)M-11-2

630 – 630KM-12-1 630(K)M-11-2

For use with For use with Alupe or For use with For use with For applications When installed on an
copper tape C 33-226 cables. other cable types. easy strip semi-conductive outdoors and in appropriate equipment
screened cables. Please contact our Please contact our screened cables. Order: humid climate. bushing:
Order: Kit MT. representative. representative. Field control mastic Order: +MWS. 1250 A continuously
(type MFC).

21
400AR-3
INTERFACE C
EQUIPMENT BUSHING

Application Technical characteristics Up to 36 kV - 630 A


For use in equipment insulated Each bushing is tested for
with oil fluid, typically for AC withstand and partial
transformers, switchgear, discharge prior to leaving
capacitors... the factory. 6/10 (12) kV
6.35/11 (12) kV
8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV
19/33 (36) kV

Specifications and
standards
The bolted type equipment
bushings 400AR-3 are moulded
epoxy insulated parts and meet
the requirements of CENELEC
EN 50180 and IEC 60137. 133

Ordering instructions 30
To order the equipment
10
bushing, specify the type.
The bushings can be supplied 330
with an earth jumper (/J).
E.g. M400AR-3/J.
For use in potentially explosive 144
atmospheres (for 12 kV max),
Minimum oil level:
order: 400AR-3/ATEX. -12 kV: 40 mm
Dia.
25
-24 kV: 50 mm
-36 kV: 70 mm

40

M16
Dia. 70
Dia. 88
Dia. 128

In mm.

Equipment Voltage Current


bushing Ur Ir
type (kV) (A)
400AR-3 12 630
01/2011

K400AR-3 24 630
M400AR-3 36 630

22
FIXINGS FOR
EQUIPMENT BUSHINGS

400AR-3/J Bushing Bushing clamping kit


To order the bushing clamping
kit, according to DIN 42 538
standards, simply specify
KBCD-400B.
bushing interface Contents: - 1 x fixing flange B
- 6 x stud clamp E
- 1 x sealing gasket.
fixing studs

fixing flange
B DIN 42 538

E DIN 42 538
stud clamp

equipment Fixing dimensions


standards DIN 42 538
sealing gasket German standards.

equipment
M10
connection

55
25

6 fixing
Dia. 90
studs
Dia. 140

earth jumper

In mm.

23
400AR-4
INTERFACE C
EQUIPMENT BUSHING

Application Technical characteristics Up to 36 kV - 1250 A


For use in equipment insulated Each bushing is tested for
with oil fluid, typically for AC withstand and partial
transformers, switchgear, discharge prior to leaving
capacitors... the factory.
6/10 (12) kV
6.35/11 (12) kV
8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV

Specifications and
standards
The bolted type equipment
bushings 400AR-4 are moulded
epoxy insulated parts and meet
the requirements of CENELEC
EN 50180 and IEC 60137. 139

Ordering instructions 36

To order the equipment 10


bushing, specify the type.
The bushings can be supplied 329

with an earth jumper (/J) or an


earth plate (/GS). This earth
connection must be specified 138
when ordering.
Minimum oil level:
E.g. M400AR-4/GS. -12 kV: 40 mm
Dia. 32
-24 kV: 50 mm
-36 kV: 70 mm

40

M16
Dia. 70
Dia. 100
Dia. 150

In mm.

Equipment Voltage Current


bushing Ur Ir
type (kV) (A)
400AR-4 12 1250
01/2011

K400AR-4 24 1250
M400AR-4 36 1250

24
FIXINGS FOR
EQUIPMENT BUSHINGS
400AR-4/GS Bushing 400AR-4/J Bushing

bushing interface

fixing studs

fixing flange

NF C 52-053
claw clamp F DIN 42 538
stud clamp

equipment

sealing gasket

equipment
connection

earth plate

earth jumper

Bushing clamping kit Bushing clamping kit


To order the bushing clamping To order the bushing clamping
kit, according to NFC 52-053 kit with DIN style fixing flange,
standards, simply specify simply specify KBCDS-400.
KBCNF-400. Contents: - 1 x fixing flange
DIN style
Contents: - 4 x claw clamp NF
- 6 x stud clamp
- 1 x sealing gasket.
F DIN 42 538
- 1 x sealing gasket.
Fixing dimensions
standards NF C 52-053 Fixing dimensions
French standards.

M10 or
M10
M12

50 to
60
70 25 30

4 fixing 6 fixing
studs Dia. 105 studs Dia. 105
Dia. 171 Dia. 171
In mm.

25
400AR-5
INTERFACE C
EQUIPMENT BUSHING

Application Technical characteristics Up to 36 kV - 1250 A


For use in equipment insulated Each bushing is tested for
with oil fluid, typically for AC withstand and partial
transformers, switchgear, discharge prior to leaving
capacitors... the factory.
6/10 (12) kV
6.35/11 (12) kV
8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV

Specifications and
standards
The bolted type equipment
bushings 400AR-5 are moulded
epoxy insulated parts and meet
the requirements of CENELEC
EN 50180 and IEC 60137.
139

Ordering instructions
To order the equipment 36
245
bushing, specify the type.
The bushings can be supplied
with an earth jumper (/J) or an Minimum oil level:
-12 kV: 40 mm Dia. 32 72
earth plate (/GS). This earth -24 kV: 50 mm
connection must be specified -36 kV: 70 mm

when ordering.
E.g. M400AR-5/GS. 32

M16
Dia. 76
Dia. 150

In mm.

Equipment Voltage Current


bushing Ur Ir
type (kV) (A)
400AR-5 12 1250
01/2011

K400AR-5 24 1250
M400AR-5 36 1250

26
FIXINGS FOR
EQUIPMENT BUSHINGS
400AR-5/GS Bushing 400AR-5/J Bushing

bushing interface

fixing studs

fixing flange

NF C 52-053
claw clamp F DIN 42 538
stud clamp
equipment
sealing gasket
equipment
connection

earth plate

earth jumper

Bushing clamping kit Bushing clamping kit


To order the bushing clamping To order the bushing clamping
kit, according to NFC 52-053 kit with DIN style fixing flange,
standards, simply specify simply specify KBCDS-400.
KBCNF-400. Contents: - 1 x fixing flange
DIN style
Contents: - 4 x claw clamp NF
- 6 x stud clamp
- 1 x sealing gasket.
F DIN 42 538
- 1 x sealing gasket.
Fixing dimensions
standards NF C 52-053 Fixing dimensions
French standards.

M10 or
M10
M12

50 to
60
70 25 30

4 fixing 6 fixing
studs Dia. 105 studs Dia. 105
Dia. 171 Dia. 171
In mm.

27
400AR-6
INTERFACE C
EQUIPMENT BUSHING

Application Technical characteristics Up to 36 kV - 630 A


For use in equipment insulated Each bushing is tested for
with oil fluid, typically for AC withstand and partial
transformers, switchgear, discharge prior to leaving
capacitors... the factory.
6/10 (12) kV
6.35/11 (12) kV
8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV

Specifications and
standards
The bolted type equipment
bushings 400AR-6 are moulded
epoxy insulated parts and meet 133
the requirements of CENELEC
EN 50180 and IEC 60137.
30

10
Ordering instructions
To order the equipment
bushing, specify the type.
The bushings can be supplied 398
with an earth jumper (/J).
This earth connection must be
specified when ordering. 213
E.g. M400AR-6/J.

Minimum oil level:


-12 kV: 40 mm Dia.
-24 kV: 50 mm 25
-36 kV: 70 mm

40

M16
Dia. 70
Dia. 74
Dia. 128 In mm.

Equipment Voltage Current


bushing Ur Ir
type (kV) (A)
400AR-6 12 630
01/2011

K400AR-6 24 630
M400AR-6 36 630

28
FIXINGS FOR
EQUIPMENT BUSHINGS

400AR-6/J Bushing Bushing clamping kit


To order the bushing clamp-
ing kit, according to DIN 42
538 standards, simply specify
KBCD-400B.
bushing interface Contents: - 1 x fixing flange B
- 6 x stud clamp E
- 1 x sealing gasket.
fixing studs

fixing flange
B DIN 42 538

E DIN 42 538
stud clamp

equipment
Fixing dimensions
standards DIN 42 538
sealing gasket German standards.

M10

55
25
equipment
connection

6 fixing
Dia. 80
studs
Dia. 140

earth jumper

In mm.

29
400SFR-B
INTERFACE C
EQUIPMENT BUSHING

Application Technical characteristics Up to 36 kV


For use in equipment insulated Each bushing is tested for 630 A & 1250 A
with SF6 gas. AC withstand and partial
discharge prior to leaving the
factory. 6/10 (12) kV
6.35/11 (12) kV
8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV
19/33 (36) kV

Dia. 70
Design
The equipment bushing is a
moulded epoxy insulated part
with a connector interface in
accordance with CENELEC EN
50180.
The 400SFR-B bushing has a
shank outside this standard, 219.5
adapted to use in SF6 gas.

Specifications and 33

standards
The bolted type equipment
bushing 400SFR-B meets the
requirements of CENELEC EN
50180 and IEC 60137.
95

Ordering instructions
To order the equipment
bushing, simply specify the
type.
M12
Dia. D
Dia. 70
Dia. 109 In mm.

Equipment Voltage Current


Dia. D
bushing Ur Ir
(mm)
type (kV) (A)
400SFR-B 12 630 25
K400SFR-B 24 630 25
M400SFR-B 36 630 25
400SFR-B 1250 A 12 1250 32
01/2011

K400SFR-B 1250 A 24 1250 32


M400SFR-B 1250 A 36 1250 32

30
FIXINGS FOR
EQUIPMENT BUSHINGS

400SFR-B Bushing for gas


insulated switchgear

UNMOUNTED

60°

60° 60°

M4

83

M6

Dia. 91.5
Dia. 103.1

equipment
MOUNTED

equipment
connection
earth
bushing
connection
interface 6 fixing M4
screws sealing
M6 O-ring
gasket

In mm.

31
400A-24B
INTERFACE C
IN-AIR BUSHING

Application Technical characteristics Up to 24 kV - 630 A


For use in equipment insulated Each bushing is tested for
with air, typically for dry AC withstand and partial
type transformers, motors, discharge prior to leaving
switchgear, capacitors... the factory.

6/10 (12) kV
6.35/11 (12) kV
8.7/15 (17.5) kV
12/20 (24) kV
12.7/22 (24) kV

Specifications and
standards
The bolted type equipment
bushings 400A-24B are
moulded epoxy insulated parts
and meet the requirements
of CENELEC EN 50180, IEC
30
60071 and IEC 60137.
20

Ordering instructions Dia. 80


To order the equipment A
bushing, specify the type. Dia. 110
The bushings are supplied with
434
an earth jumper.
To include the ring clamp, add:
  
250
!   
""   #
E.g. 400A-24B/D.
For use in potentially explosive
Dia.
atmospheres (for 12 kV max), 25
order: -/ATEX.

40

B M16
Dia. 80
In mm.

Equipment Voltage Current Creepage distance


bushing Ur Ir A-B
type (kV) (A) (mm)
01/2011

400A-24B 12 630 520


400A-24B 24 630 520

32
FIXINGS FOR
400A-24B In-air bushing
EQUIPMENT BUSHINGS
bushing interface

fixing studs and


nuts M10

earth jumper

equipment

gasket

equipment
connection

fixing flange
BCA-B or fixing flange
BCA-D BCA-F

Dia.12 Dia.12
Dia. 94.5 Dia. 94.5
4 4
10 10
Dia. 111 Dia. 111

120°

126

120°
BS 2562 stand.: 120
DIN 42 538 stand.: 123 Dia. 150
Dia. 150
Type BCA-B : BS 2562 British standards Type BCA-F : NFC 52-053 French standards
Type BCA-D : DIN 42 538 German standards

Fixing dimensions Fixing dimensions


standards DIN 42 538 standards NF C 52-053
German standards. French standards.

M10 M10

55 52
20 20

4 fixing 3 fixing
studs studs

Dia. 82 Dia. 82 In mm
Dia. 123 Dia. 126

33
300SA
SURGE ARRESTER
FOR 430TB AND 434TB CONNECTOR

Application Technical characteristics Up to 36 kV


Surge arrester designed to $!
protect 12, 24 and 36 kV oxide varistor surge arrester in
class components, including an elbow configuration.
transformers, equipment, cable    % 6/10 (12) kV
and accessories from high withstand, partial discharge 6.35/11 (12) kV
voltage surges resulting from and critical voltage prior to 8.7/15 (17.5) kV
lightning or switching. leaving the factory. 12/20 (24) kV
It has been designed to be 12.7/22 (24) kV
used with the 430TB or 434TB 18/30 (36) kV
separable tee connector. 19/33 (36) kV

Design 170 mm
Surge arrester comprising: 105 mm
1. Interface designed to fit the
430TB/G or 434TB/G tee
connector.
2. Conductive EPDM insert. Dia.
75 mm
3. Conductive EPDM jacket.
4. Insulating EPDM layer
moulded between the insert 1
and the jacket.
5. Receptacle for contact rod. 5
6. Metal oxide valve elements. 2
7. Steel cap.
8. Earth connection. 3 9
L2
9. Earth lead.
L1
4
Specifications and 6
standards
The 300SA surge arresters meet
the test requirements of IEC Dia.
60099-4. 65 mm

7
8

Nominal Max. continuous Dimensions


Surge Rated
discharge operating (mm)
arrester voltage
current voltage
type Ur (kV)
In (kA) Uc (kV) L1 L2
300SA-10-15N 10 15 12.0 230 270
300SA-10-18N 10 18 14.4 230 270
300SA-10-22N 10 22 17.6 230 270
300SA-10-24N 10 24 19.2 320 360
300SA-10-30N 10 30 24.0 320 360
01/2011

300SA-10-36N 10 36 28.8 320 360


300SA-10-45N 10 45 36.0 430 470

34
Typical application and Ordering instructions
dimensions To order the surge arrester,
specify the surge arrester type,
as described on previous page.
290 mm
Example:
180 mm 107 mm
For a maximum continuous
operating voltage (r.m.s.) of
24 kV and a nominal discharge
current of 10 kA.
Order a 300SA-10-30N surge
arrester.

Type 300SA
surge arrester

Type
430TB or
434TB
tee connector

Technical data

Steep current Lightning current Switching impulse High current


Surge residual voltage residual voltage
residual impulse
arrester [8/20 μs] (kV) [36/90 μs] (kV)
voltage @ 10 kA withstand
type
[1/20 μs] (kV) (kA)
@ 5 kA @ 10 kA @ 20 kA @ 125 A @ 500 A
300SA-10-15N 48.1 39.7 43.2 48.4 30.5 32.5 100
300SA-10-18N 58.1 48.0 52.2 58.5 36.8 39.2 100
300SA-10-22N 70.1 57.9 63.0 70.6 44.4 47.3 100
300SA-10-24N 77.0 63.6 69.2 77.6 48.8 52.0 100
300SA-10-30N 97.0 80.1 87.2 97.7 61.5 65.5 100
300SA-10-36N 115.9 95.7 104.2 116.8 73.5 78.3 100
300SA-10-45N 144.1 119.0 129.5 145.1 91.3 97.3 100

35
400PB-XSA
INTERFACE C
SURGE ARRESTER

Application Technical characteristics Up to 36 kV


Surge arrester designed $!
to protect medium voltage oxide varistor surge arrester in 6/10 (12) kV
components, including an elbow configuration. 6.35/11 (12) kV
transformers, equipment, cable    % 8.7/15 (17.5) kV
and accessories from high withstand, partial discharge 12/20 (24) kV
voltage surges resulting from and critical voltage prior to 12.7/22 (24) kV
lightning or switching. leaving the factory. 18/30 (36) kV
19/33 (36) kV

Design 252 mm
Surge arrester comprising: 150 mm
1. Conductive EPDM insert.
2. Conductive EPDM jacket.
3. Insulating EPDM layer Dia.
moulded between the insert 80 mm
and the jacket.
4. Contact rod. 4
5. Earthing lead.
6. Earth connection. 1 9
7. Steel cap.
2
8. Metal oxide valve elements.
5
9. Type C - 630 A interface 3
L2
as described by CENELEC
L1
EN 50180 and 50181.
8

Specifications and
standards Dia.
70 mm
The 400PB-XSA surge arresters
meet the test requirements of 7
IEC 60099-4.
6

Nominal Max. continuous Dimensions


Surge Rated
discharge operating (mm)
arrester voltage
current voltage
type Ur (kV)
In (kA) Uc (kV) L1 L2
400PB-5SA-15L 5 15 12.0 250 290
400PB-5SA-18L 5 18 14.4 250 290
400PB-5SA-22L 5 22 17.6 350 390
400PB-5SA-24L 5 24 19.2 350 390
400PB-5SA-30L 5 30 24.0 350 390
400PB-10SA-15N 10 15 12.0 250 290
400PB-10SA-18N 10 18 14.0 250 290
400PB-10SA-22N 10 22 17.6 350 390
400PB-10SA-24N 10 24 19.2 350 390
400PB-10SA-30N 10 30 24.0 350 390
01/2011

400PB-10SA-36N 10 36 28.8 350 390


400PB-10SA-45N 10 45 36.0 450 490

36
Typical applications and Ordering instructions
dimensions To order the surge arrester,
specify the surge arrester type,
as described on previous page.
410 mm
Example:
220 mm 185 mm For a maximum continuous
operating voltage (r.m.s.) of
24 kV and a nominal discharge
current of 10 kA.
Order a 400PB-10SA-30N
surge arrester.

Type
400TB
Type 400PB-5SA
or 440TB
or 400PB-10SA
tee connector
surge arrester

Technical data

Steep current Lightning current Switching impulse High current


Surge residual voltage residual voltage
residual impulse
arrester [8/20 μs] (kV) [36/90 μs] (kV)
voltage @ 10 kA withstand
type
[1/20 μs] (kV) (kA)
@ 5 kA @ 10 kA @ 20 kA @ 125 A @ 500 A

400PB-5SA-15L 47.1 38.9 42.3 47.4 29.8 31.8 65


400PB-5SA-18L 56.5 46.7 50.8 56.9 35.8 38.2 65
400PB-5SA-22L 69.2 57.1 62.2 69.7 43.8 46.7 65
400PB-5SA-24L 75.2 62.1 67.6 75.8 47.7 50.8 65
400PB-5SA-30L 94.0 77.6 84.5 94.7 59.6 63.5 65
400PB-10SA-15N 48.1 39.7 43.2 48.4 30.5 32.5 100
400PB-10SA-18N 58.1 48.0 52.2 58.5 36.8 39.2 100
400PB-10SA-22N 70.1 57.9 63.0 70.6 44.4 47.3 100
400PB-10SA-24N 77.0 63.6 69.2 77.6 48.8 52.0 100
400PB-10SA-30N 97.0 80.1 87.2 97.7 61.5 65.5 100
400PB-10SA-36N 115.9 95.7 104.2 116.8 73.5 78.3 100
400PB-10SA-45N 144.1 119.0 129.5 145.1 91.3 97.3 100

37
400TR and 400TR-LB
INTERFACE C
TEST RODS
Application Technical characteristics
      *  <==>   
- cable fault location be used with 400TE,
- cable testing 430TB, 400TB and 440TB
- phasing checks, etc. connectors.
 %   !;!   <==>?@ Q
with a cable lug, a 4 mm the 400LB connector.
plug or spring clips.

400TR 400TR-LB
Design
1. Insulating shroud.
2. Threaded rod for test
connection. 1
3. Two nuts M12.
4. Insulation.
M10
5. Copper test rod stem.
6. Wing nut. 1
2
An insulating shroud is M12 60
provided to allow the 2 6
application of test voltages
3 40
when bushings are closely
spaced.

480
465
Installation
The test rod is mounted on
4
to the clamping screw in
the type C interface tee and
coupling connectors. The 310
4 288
test cable is connected to Dia.
25
the threaded stem and the
insulating shroud moved to its 5
final position over the end of
the test rod.

5
Ordering instructions
Simply specify:
400TR or 400TR-LB test rod.
In mm.

Maximum A.C. Maximum D.C. Impulse voltage


Test rod
test voltage test voltage (1.2 x 50 μs)
type
(50 Hz - 1 min) (8 x U0 - 30 min) min
01/2011

400TR 36 kV 96 kV 95 kV
400TR-LB 36 kV 96 kV 95 kV

38
400TK & 400SW
INSTALLATION TOOL

Application  <==[\ Y 


  Y   Y key fits on the hex nut of the
spanner key are designed 400BIPA basic insulating
to facilitate assembly of plug.
400TE, 400TB and 440TB
connectors.
 <==Z Y 
used to install the 400TEF
clamping pin contact or
400TCS clamping screw.

400SW
400TK

Ordering instructions
Simply specify:
- 400TK box spanner
01/2011

- 400SW box spanner key

39
ACCESSORIES
INTERFACE C

Application Technical characteristics Up to 36 kV


For use with connectors and All these products, except the
bushings with an interface C earthing plugs, are tested for
as described by CENELEC EN
6/10 (12) kV
AC withstand and partial
50180 and 50181.
6.35/11 (12) kV
discharge prior to leaving
8.7/15 (17.5) kV
the factory.
12/20 (24) kV
12.7/22 (24) kV
18/30 (36) kV
19/33 (36) kV

400DR-B Ordering instructions


Dead-end receptacle Order
Fits over a bushing with a type 400DR-B for 12 kV,
C interface to provide 'dead- K400DR-B for 24 kV or
end' facility. M400DR-B for 36 kV
applications.
The dead-end receptacle can
be supplied with an earth lead.
Order with suffix -/G.
E.g. K400DR-B/G.

400SOP-B Ordering instructions


Stand-off plug Order
Is designed to support and 400SOP-B for 12 kV,
'dead-end' connectors with a K400SOP-B for 24 kV,
type C interface when removed M400SOP-B for 36 kV or
from equipment. P400SOP-B for 41.5 kV
applications.

400GP-B Ordering instructions


Earthing plug Order
Is designed to support and 400GP-B for 12, 24, 36 or
earth connectors with a type C 41.5 kV applications.
interface when removed from
equipment.

300GP-B Ordering instructions


Earthing plug Order
Is designed to earth the 430TB 300GP-B for 12, 24, 36 or
and 434TB connectors when it is 41.5 kV applications.
01/2011

fixed-mounted to the equipment


(maintenance earthing).

40
400BIPA Ordering instructions
Basic insulating plug Order
Acts as a tightening nut for 400BIPA for 12 kV,
the 400TB and 440TB tee K400BIPA for 24 kV
connector kits. M400BIPA for 36 kV or
The plug contains a voltage P400BIPA for 41.5 kV
detection point. applications.
The conductive rubber
protection cap is included.

430CP Ordering instructions


Connecting plug Order
For connecting two or more 430CP for 12 kV or
430TB connectors, thus creating K430CP for 24 kV applications.
a separable cable joint or a
multiple cable connection to
equipment.

400CP-SC Ordering instructions


Connecting plug Order
For connecting two or more 400CP-SC for 12 kV,
connectors with a type C K400CP-SC for 24 kV or
interface together, thus creating M400CP-SC for 36 kV
a separable cable joint or a applications.
multiple cable connection to
equipment.

440CP Ordering instructions


Connecting plug Order
For connecting two or more 440CP for 12 kV,
440TB connectors, thus creating K440CP for 24 kV or
a separable cable joint or a M440CP for 36 kV
multiple cable connection to applications.
equipment.
Order (K)(M)440CP + 676SA
For use up to 1250 A.
for connection to an already
Only for use with 440TB.
installed 440TB connector.

400RTPA Ordering instructions


Reducing tap plug Order
Provides a type A interface 400RTPA for 12 kV or
to connectors with a type C K400RTPA for 24 kV
interface. applications.
A 'C' spanner, 600SW, is used
to tighten the reducing tap plug Order 600SW for the 'C'
on to its mating part. spanner.

Kit MT Ordering instructions


Earthing kit for copper Order
tape screened cables Kit MT for 12 kV, 24 kV
Contains a tinned copper braid 36 kV or 41.5 kV applications.
(25 mm² - L = 500 mm), a
tinned copper wire for cleating
and some water sealing mastic.

41
POSSIBLE ARRANGEMENTS
INTERFACE C

430TB 430TBM-P2
Single cable arrangement. Dual cable arrangement.
Order 430TB for 12 kV, Order 430TBM-P2 for 12 kV,
K430TB for 24 kV or M430TB K430TBM-P2 for 24 kV or
for 36 kV applications. M430TBM-P2 for 36 kV
applications.

185 290

300BIPA
300BIPA
basic
basic
insulating
insulating
plug
plug

300PBM
430TB tee coupling
connector connector

430TB tee
connector

110 105

430TBM-P3 430TBM-L3
Triple cable arrangement. 3-way connection.
Order 430TBM-P3 for 12 kV, Order 430TBM-L3 for 12 kV,
K430TBM-P3 for 24 kV or K430TBM-L3 for 24 kV or
M430TBM-P3 for 36 kV M430TBM-L3 for 36 kV
applications. applications.

425

300BIPA 300BIPA
basic basic
insulating insulating
plug plug
400BIPA
basic
300PBM 300PBM
insulating
coupling coupling
plug
connectors connectors

430TB tee
430TB tee connector
connector
01/2011

In mm.

42
434TB 434TBM-P2
Single cable arrangement. Dual cable arrangement.
Order 434TB for 12 kV, Order 434TBM-P2 for 12 kV,
K434TB for 24 kV or M434TB K434TBM-P2 for 24 kV or
for 36 kV applications. M434TBM-P2 for 36 kV
applications.

185 345

300BIPA 300BIPA
basic basic
insulating insulating
plug plug

434TB
434TB tee tee
connector connector

440PB
coupling
connector

110 110 155

434TBM-P2 + 300SA 440TB + 400PB-XSA


Dual cable arrangement with Cable arrangement with surge
surge arrester. arrester.
Order 434TBM-P2+300SA for Order 440TB+400PB-XSA for
12 kV, K434TBM-P2+300SA for 12 kV, K440TB+400PB-XSA for
24 kV or M434TBM-P2+300SA 24 kV or M440TB+400PB-XSA
for 36 kV applications. for 36 kV applications.

450 410

300BIPA
400BIPA
basic
basic
insulating
insulating
plug
plug
300SA
surge arrester 400PB-XSA
surge arrester
434TB
tee connector 440TB
tee connector
440PB
coupling
110 155 connector
110

43
400TB/G 400TB/G-P2
Single cable arrangement. Dual cable arrangement.
Order 400TB/G for 12 kV, Order 400TB/G-P2 for 12 kV,
K400TB/G for 24 kV, K400TB/G-P2 for 24 kV or
M400TB/G for 36 kV or M400TB/G-P2 for 36 kV
P400TB/G for 41.5 kV applications.
applications.
250 500

basic
insulating
plug
tee
connecting basic
connector
plug insulating
plug

110 110 245

400TB/G-L2
2-way connection.
Order 400TB/G-L2 for 12 kV,
K400TB/G-L2 for 24 kV or
M400TB/G-L2 for 36 kV
applications.

400TB/G-L3
3-way connection.
Order 400TB/G-L3 for 12 kV,
K400TB/G-L3 for 24 kV or
M400TB/G-L3 for 36 kV
applications.

In mm.

44
400TB/G-L4
Disconnectable tap-off.
Order 400TB/G-L4 for 12 kV,
K400TB/G-L4 for 24 kV or
M400TB/G-L4 for 36 kV
applications.

400TB/G-L5 505
2-way connection with tap-off.
Order 400TB/G-L5 for 12 kV
or K400TB/G-L5 for 24 kV
applications.

Connector on stand-off
plug
Order 400SOP-B for 12 kV,
K400SOP-B for 24 kV or
M400SOP-B for 36 kV
applications.

300BIPA 400BIPA
basic basic
insulating insulating
plug plug

400TB/G tee
stand-off 430TB tee stand-off connector
plug connector plug

In mm.

45
Earthing plug on Connector on earthing
connector plug
Order 300GP-B for 12 kV, Order 400GP-B for 12 kV,
24 kV and 36 kV applications. 24 kV and 36 kV applications.

Cable and equipment


testing

In mm.

46
Additional catalogue information on power cable accessories
is available by contacting us at the address below: