Deltƒ Mƒtrix: High Performance, Configurable Pick-and-Place Handler
Deltƒ Mƒtrix: High Performance, Configurable Pick-and-Place Handler
F l ex i b i l i ty
n 3 x 3 mm to 51 x 51 mm package handling
n Compatible with existing test site pitches
deltƒ mƒTRiX
High Performance, Configurable Pick-and-Place Handler
Specifications
PLATFORM Specified values are dependent on the use of contactors
Media that comply with Cohu ITS’s thermal contactor
specification (results may be better — device-dependent)
JEDEC trays
Soak capacity: 3 trays
Input and Sorts
DUT Thermal Conditioning
7 - Automated tray stacks
3 - Manual trays in pullout drawer T-Core Thermal Options
LN2 cooled
Test Site
Multiple feed loop options*
x1 to x32
Pitch – x: 31.75 mm up to 80 mm Patented thermal interface technology
Pitch – y: 30 mm up to 80 mm Single insertion multiple temperatures (optional)
Horizontal docking
Tester Interface
Custom pitches optional
Loadboard compatibility (X and Y pitch)
Plunge Force
Docking height 990 to 1,178 mm
227 kgf
Universal docking design can reuse most existing
480 and 567 kgf (optional)
interface hardware
NVcore Vision Options RS 232, GPIB and P849
2DID Parallel (optional)
In-Socket Part Detection
ESD Control
Index Time*
Decay: 1,000V to 100V in 10 s
x1 to x4: 550 ms Balance: ±50V
x8: 630 ms Class 0 ±5V (optional)
x16: 800 ms User Interface
x32: 3,900 ms Windows-based color touchscreen
Throughput * Power Requirements
Up to 9,000 uph 200-240 VAC, 50/60Hz, Three Phase, 32 A
Up to 16,000 uph (optional)
Standards
Jam Rate*
1 in 12,000 units (ambient-hot) , Certified per SEMI S2/S8 and NFPA 79 requirements
1 in 5,000 units (cold)
KITS
Productivity
Device Type
Auto Retest
QFP, TQFP, TSOP, SOIC, CSP, BGA, QFN, WLCSP
Continuous Load/Unload and others
Auto Temperature Calibration
Package Size
Lot Cascading (optional)
Minimum: 3 mm x 3 mm
Auto Contactor Cleaning (optional) Maximum: 51 mm x 51 mm
Temperature Range
Package Changeover
+50°C to +155°C
< 30 minutes typical
-55°C to +155°C (optional)
Contactors
+175ºC (optional)
Cohu ITS high-performance or customer-specified
Thermal (Base)* contactors
Chamberless tri-Temperature test site
Docking
Active Thermal Control per site
Supports Delta Design universal docking
Temperature Accuracy (with thermal contactors)
All standard docking
x1 to x8: ±2°C
x16 to x32: ±4°C
+175°C: ±5°C