Elmag 200: Electromagnetic Flow Meter
Elmag 200: Electromagnetic Flow Meter
Elmag 200: Electromagnetic Flow Meter
®
ELMAG 200
ELECTROMAGNETIC FLOW METER
Features
Description
E
lectronet series ELMAG®-200 are micro-controller based full
bore type electromagnetic flow meters specially used for
various industrial applications. These flow meters accurately
measure the flow rate of conductive liquids and slurries in closed pipes.
Due to its simple and rigid design, the flow meter is an obstruction less and maintenance-free instrument in place of conventional
mechanical flow measuring devices. The use of ‘Pulsed DC’ technology offers highest ability and better measuring accuracy in the
form of electrical signal 4-20 mA DC linearly proportional to volumetric flow. The instrument is based on Faraday’s law of
electromagnetic induction. A magnetic ?eld is generated by the instrument in the flow tube. The fluid flowing through this magnetic
field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to
measuring flow range.
Technical Specifications
Media Liquids (Conductive)
Conductivity > 5 µs/cm
Viscosity 200 cp max
Line Size 15 NB to 2000 NB
Excitation Pulsed DC
Type of Output 1) 4 to 20mA DC
2) 4 to 20mA DC (HART Compatible)
3) 4 to 20mA DC + Pulse Output / Frequency Output
4) 4 to 20mA DC (HART Compatible) + Pulse output / Frequency Output
Display 16 x 2 LCD - 6 Digit for Flow Rate & 8 Digit for Totalizer Flow
3
Engineering Unit User Programmable (m /hr by default)
Calibration Range Wet Calibrated on IEC/ISO/EN17025 Accredited Calibration Rig.
Accuracy +/- 0.5% of M.V. (For Flow Velocity > 0.5 m/s)
Flow Velocity Range -6 m/s to +6 m/s
Linearity +/- 0.5% of M.V.
Certification
www.eeplindia.com EEPL-S011C-070119 1
ELECTROMAGNETIC FLOW METER ELMAG® - 200
Assembly Overview
132mm 198 mm
Electronics Cable Entry
Enclosure
ø 115 mm
ELMAG®-200
0000.00 m3/Hr
000000.02 m3 LH
ELECTROMAGNETIC FLOW METER
ELECTRONET
Coil Housing
ø DBC
øR
MS Flange
Flange
D
FD
www.eeplindia.com EEPL-S011C-070119 2
ELECTROMAGNETIC FLOW METER ELMAG® - 200
TABLE : Dimensional Details Of Flange (as Per ANSI 150 # B-16.5) & Finished Product
Refer Drg. Fig.1 & 2
Line Size Flange Diameter Diameter Diameter No. Thickness Housing Flange to FD FD With Flow Range (m3/hr)
Diameter of Raised of Bolt of of of OD Flange with Grounding at 0.3m/s to 6m/s
D (mm) Face Hole Circle Bolt Hole Holes Flange (mm) Distance Lining Ring (mm)
Inch NB R (mm) DBC (mm) (mm) (FD) (mm) (mm) Min. Max.
½” 15 88.9 34.9 60.3 15.9 4 11.1 125 190 196 204 0.19 3.817
¾” 20 98.4 42.9 69.8 15.9 4 12.7 125 190 196 204 0.33 6.785
1” 25 107.9 50.8 79.4 15.9 4 14.3 145 190 196 204 0.53 10.602
1¼” 32 117.5 63.5 88.9 15.9 4 15.9 155 190 196 204 0.86 17.371
1½” 40 127.0 73 98.4 15.9 4 17.5 155 190 196 204 1.35 27.143
2” 50 152.4 92.1 120.6 19.0 4 19.0 165 190 196 204 2.12 42.4115
2½” 65 177.8 104.8 139.7 19.0 4 22.2 185 190 196 204 3.58 71.675
3” 80 190.5 127.0 152.4 19.0 4 23.8 205 190 198 206 5.42 108.573
4” 100 228.5 157.2 190.5 19.0 8 23.8 245 240 248 256 8.48 169.646
5” 125 254.0 185.7 215.9 22.2 8 23.8 265 240 250 258 13.25 265.071
6” 150 279.4 215.9 241.3 22.2 8 25.4 285 290 300 308 19.085 381.703
8” 200 342.9 269.9 298.4 22.2 8 28.6 355 340 350 358 33.929 678.584
10” 250 406.4 323.8 361.9 25.4 12 30.2 405 440 452 460 53.014 1060.28
12” 300 482.6 381.0 431.8 25.4 12 31.8 485 490 502 510 76.340 1526.81
14” 350 533.4 412.7 476.2 28.6 12 34.9 555 540 552 560 103.908 2078.16
16” 400 596.9 469.9 539.7 28.6 16 36.5 605 590 602 610 135.716 2714.33
18” 450 635.0 533.4 577.8 31.7 16 39.7 605 590 602 610 171.766 3435.33
20” 500 698.5 584.2 635.0 31.7 20 42.9 630 590 600 608 212.057 4241.15
24” 600 812.8 692.1 749.3 34.9 20 47.6 755 590 600 608 305.362 6107.25
Note : Flange to flange distance (FD) Tolerance : 1) 1/2"(15NB) to 6"(150NB) : +/-3mm 2) 8"(200NB) to 24"(600NB) : +/-5mm
All dimensions are in ‘mm’ Wet Calibrated on IEC/ISO/EN17025 Accredited Calibration Rig.
For dimensions of line size above 600NB, please consult factory. Flow meter should be selected with the help of Nomograph (recommended full scale velocity).
Typical mounting dimensions are for reference only. Flow indication of 6 digit max. up to 999999.
Flow Nomograph
1.0%
0.9%
0.8%
Measuring error (% M.V)
0.7%
0.6%
0.5%
0.4%
0.3%
0.2%
0.1%
0.0%
0 1 2 3 4 5 6 m/s
Flow Velocity
Applications
www.eeplindia.com EEPL-S011C-070119 3
ELECTROMAGNETIC FLOW METER ELMAG® - 200
Ordering Information
Sample Order Code : 01A-07B-09B-10D-22A-23B-24B-50B-51B-52A-53F-66B-67C-68C-69F-70A-71A-72B-73A
Parameter Code Value Code Value Parameter Code Value
01A 15 NB 01P 400 NB 53E Profibus
Communication
01B 20 NB 01Q 450 NB 53 53F GPRS
Output 1
01C 25 NB 01R 500 NB 53Y None
01D 32 NB 01S 600 NB 66A Threaded
Process
01E 40 NB 01T 700 NB 66 66B Flanged
Connection
01F 50 NB 01U 800 NB 66E * Tri Clover
01G 65 NB 01V 900 NB 67A MS
01 Line Size 01H 80 NB 01W 1000 NB 67B CS
01I 100 NB 01AA 1100 NB 67C SS316
67 MOC Flange
01J 125 NB 01AB 1200 NB 67D SS304
01K 150 NB 01AC 1400 NB 67E PVC
01L 200 NB 01AD 1500 NB 67Z NA
01M 250 NB 01AE 1600 NB 68A MS
01N 300 NB 01AF 1800 NB MOC 68B SS304
68
01O 350 NB 01AG 2000 NB Coil Housing 68C SS316
Area 07A Weather Proof 68D PVC
07
Classification 07B Flame Proof 69A Neoprene Rubber
09A Integral 69B Hard Rubber
09 Electronics
09B Remote 69C Ebonite Rubber
10A 2 Meter 69D EPDM
Lining
10B 5 Meter 69 69E PFA
Material
Remote Cable 10C 10 Meter 69F PTFE
10
Length 10D 15 Meter 69G PU
10E 25 Meter 69H Ceramic
10Z NA 69X Other
MOC 22A Die Cast Aluminium 70A ANSI
22 Electronics 22B SS316 70B DIN
Flange
Enclosure 22C ABS Plastic 70 70C AWWA
Standard
23A M20 X 1.5 70X Other
23 Cable Entry 23B ½” NPTF 70Z NA
23X Other 71A ANSI 150
Power 24A 90 - 250 VAC 71B ANSI 300
24
Supply 24B 24 VDC 71C ANSI 600
50A 4 to 20 mA 71D DIN 10
71 Flange Rating
50 Output 1 50B 4 to 20 mA with HART 71E DIN 16
50Y None 71F DIN 40
51A Pulse 71X Other
51 Output 2 51B Freq (0 to 1 KHz) 71Z NA
51Y None MOC 72B SS304
72
52A 1 Alarm Flow Tube 72C PVC
Alarm
52 52B 2 Alarm 73A SS 316L
Status Output
52Y None 73B Hastelloy
MOC
53A RS 485 73 73C Platinum
Communication Electrode
53 53B RS 232 73D Tantalum
Output 1
53C GSM 73E Titanium
Note : Due to our continuous product revisions, design specification and model numbers are subject to change without notice. To be used for industrial applications.
Accuracy defined at Lab Conditions. For other requirement please consult factory. * Process connection -Tri Clover : Upto Max. 4 inch Line Size
EEPL-S011C-070119 4