100% found this document useful (1 vote)
238 views1 page

Psychrometric Chart

The document is a psychrometric chart that shows temperature and humidity values at different conditions. It displays lines for specific enthalpy, humidity ratio, and other thermodynamic properties. The chart allows users to determine thermodynamic properties of air at various temperature and moisture levels.

Uploaded by

Abhi Ram M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
238 views1 page

Psychrometric Chart

The document is a psychrometric chart that shows temperature and humidity values at different conditions. It displays lines for specific enthalpy, humidity ratio, and other thermodynamic properties. The chart allows users to determine thermodynamic properties of air at various temperature and moisture levels.

Uploaded by

Abhi Ram M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ASHRAE Psychrometric Chart No.

1
Normal Temperature
Barometric Pressure: 101.325 kPa

©1992 American Society of Heating, 0.36


Refrigerating and Air-Conditioning Engineers, Inc.
30
Sea Level
100

0.9
28 0.40
30

4
∑ 1.0 1.0 –∑
0.8 1.5
10.0 0.7 2.0 – 5.0 120
0.6 4.0 – 2.0 26
Sensible heat DHS – ∑ 90
0.5 —————– = —— – 4.0 30
Total heat DHT – 2.0 0.0
5. 0 0.4 1.0 0.45
–0
1.0 24
3
0.

4.0
– 0.2

.5
0.2

0.1

= ——
DHT
DHS
0 80

0.9
r 110

Humidity ratio ( ) grams moisture per kilogram dry air


ai

2v
2.0

22
3.0

y
dr 0.50

olu
2.5

—————–
Sensible heat
am

me
gr

Total heat
Enthalpy Dh lo 70
ki 25

cu
—————— = —— r 20
Humidity ratio D

bic
pe 0.55
es

met
ul
jo 100
li o

er
25
)k we

per
%
18
(h t bu

90
60 lb t 0.60

0.9
y

kilo
lp em
a per

0
th atu

gra
%
En re °

80
C

md
°C 16 0.65
re

ry a
tu

%
50 20
ra

70
90
pe

ir
0.70
m
te

14
n

%
tio

60 0.75

0.8
ra

20
tu

8
Sa

40 0.80
% 12
50 0.85
15 80 0.90
% 10 0.95
30 0.8 40
15 6 1.0

10 30% 8
20
0.8

70
10
4

6
5 20%
0.8

5
2

y 4
umidit
lative h
10% re
0.8

0 60
0
0.7

2
8

APPENDIX 1
943
0 10 20 30 40 50

Dry bulb temperature °C

Prepared by Center for Applied Thermodynamic Studies, University of Idaho.

FIGURE A–31
Psychrometric chart at 1 atm total pressure.
Reprinted by permission of the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA; used with permission.