A simple, highly sensitive ion chromatographic method for the hydrochloride salts of these chemicals are commonly used as feed
simultaneous determination of betaine, choline and carnitine in or premix additives to increase the feed efficiency.
feed premixes is described. Premixes were extracted via ultra- Existing analytical techniques for the determination of choline,
sonication in water for 20 min and extracts were analyzed by ion carnitine and betaine in various matrices include enzymatic reac-
chromatography using an aqueous 3.0 mmol L1 methane sulfonic tions,14–16 liquid chromatography17–20 and mass spectrometry,21–23
acid solution containing 15% (v/v) acetonitrile as the eluent and an with the enzymatic methods the most commonly used. Enzymatic
IonPac SCS1 column. The composition of the mobile phase was techniques, however, are sensitive to matrix interference. The
optimized for the efficient separation of the three main analytes inuence of proteins and inorganic salts in the catalase assay of
from each other as well as from common inorganic cations and carnitine in serum has already been reported15 and similar inter-
trimethylamine, which is an ingredient for the synthesis of the ference may occur in complex feed matrices. Several enzymatic
analytes. The recoveries of choline, carnitine and betaine spikes methods for choline have been developed that rely on reactions
added to premixes were all greater than 90% with replicate relative catalyzed by choline oxidase (ChOx) to convert choline into
standard deviations of less than 10%. The limits of detection of this betaine,16 but the use of such methods does not allow the simul-
method for these analytes in premixes were calculated to be 10, 6 taneous analysis of choline and betaine within the same sample. As
and 20 mg kg1, respectively. an alternative, high pressure liquid chromatography (HPLC) may be
used to quantify these analytes in a wide variety of products,
although the majority of HPLC methods for feed compounds
1 Introduction require derivatization or the use of complex purication protocols
Choline is a common dietary supplement for both animals and prior to analysis.17–20 As an example, the pre-column derivatization
humans, owing to its role in several metabolic pathways, including of carnitine to yield a uorescent derivative is one of the strategies
carotene metabolism and the formation of cell structures. It is also a used to address the lack of a chromophore in this molecule.19 Assays
major source of methyl groups within metabolic processes and a used to determine betaine concentrations in feed ingredients also
precursor of acetylcholine.1–3 Carnitine is a quaternary ammonium require pre-purication using an SCX column.17 Mass spectrometry
compound that is biosynthesized from the amino acids lysine and is another analytical technique commonly used to quantify analytes
methionine. The primary metabolic role of carnitine is the transport in plant tissues and plasma. The required instrumentation,
of long-chain fatty acids across the mitochondrial membrane, as a however, is quite expensive and for this reason is not commonly
prelude to the b-oxidation of the acids to produce energy.4,5 Betaine available in nutrition laboratories. Another option is ion chroma-
is formed by the oxidation of choline1 and functions as a dietary tography (IC), which has been applied to the determination of
source of methyl groups and has a role in cell volume regulation in choline in infant formula and betaine in feed,24,25 but has not been
animals under osmotic stress conditions.6,7 The molecular struc-
tures of these compounds are provided in Fig. 1. Several studies
have reported that dietary supplementation with these compounds
signicantly improves both the growth performance and carcass
quality of animals raised for food purposes,8–13 and thus the
This journal is ª The Royal Society of Chemistry 2013 Anal. Methods, 2013, 5, 59–63 | 59
View Article Online
2.4 IC conditions
The chromatographic column was a Dionex IonPac SCS 1 analytical
column (250 mm " 4 mm i.d.) with a Dionex IonPac SCG 1 guard
Fig. 2 The resolution of TMA and carnitine peaks at mobile phase MSA
concentrations from 2.0 to 4.0 mmol L1.
column (50 mm " 4 mm i.d.). The optimized eluent was an
1
aqueous solution of 3.0 mmol L
1
MSA with 15% (v/v) acetonitrile.
1
Separation was carried out at a ow rate of 1 mL min 1
and a
constant column temperature of 30 ! C.
reported for the simultaneous determination of choline, carnitine
and betaine in premixes. To address the deciencies noted above, 3 Results and discussion
we have developed a simple and fast ion chromatographic method
3.1 Optimization of chromatographic performance
for the simultaneous detection of these analytes. As part of the
method development, the mobile phase composition was opti- All of the analytes, as well as TMA, have the same amine functional
mized for the efficient separation of the analytes from common group and similar structures, and therefore their chromatographic
inorganic cations as well as from trimethylamine (TMA), which is a separation with baseline resolution is not trivial. To determine the
raw ingredient for the synthesis of the analytes and therefore may be optimum MSA concentration in the mobile phase, different MSA
expected to be present in premixes. concentrations ranging from 1.5 mmol L1 to 4.5 mmol L1 were
employed. Each of these MSA concentrations produced good
chromatographic separation of betaine, carnitine and choline.
2 Materials and methods However, there were signicant effects of the MSA concentration on
the resolution of TMA and carnitine, as illustrated in Fig. 2, such
2.1 Reagents and solutions that the resolution of these two analytes decreased with increasing
All reagents were of analytical grade unless otherwise stated. MSA concentration. A concentration of 3 mmol L1 MSA was found
Methane sulfonic acid (MSA), TMA hydrochloride and choline to satisfactorily separate TMA and carnitine (R ¼ 1.60). Although
chloride were obtained from Sigma Aldrich Co., LLC (St. Louis, MO, lower MSA concentrations resulted in better separation, they also
USA). L-Carnitine and betaine hydrochloride were obtained from produced longer retention times and unsatisfactory peak shapes
Aladdin Reagent Co. (Shanghai, China). Water was puried by a and hence 3 mmol L1 MSA was considered to be optimal for the
Milli-Q Plus water system (Millipore, Bedford, MA, USA). Standard separation of carnitine and TMA.
solutions of inorganic cations were obtained from the National A further challenge was presented by unsatisfactory resolution
Institute of Metrology (Beijing, China). All solutions used for IC were between choline and Mg2+ and betaine and Na+ when using the 3
rst ltered through a 0.45 mm lter and degassed. Blank premixes mmol L1 MSA mobile phase. Since many feed premixes contain
and premixes containing the desired analytes were obtained from a signicant quantities of Mg and Na, different mobile phase aceto-
local market in China. nitrile percentages ranging from 0% to 20% (v/v) were tested while
Stock solutions were prepared in methanol at a concen- keeping the concentration of MSA constant, to determine the
tration of 1 mg mL1 and kept at 0 to 4 ! C for no longer than optimum acetonitrile concentration. The signicant effects of
six months. Working solutions used for method validation mobile phase acetonitrile concentration on the analyte retention
were prepared in water, sealed and kept at 0 to 4 ! C for no times are summarized in Fig. 3. As a result of their interactions with
longer than four weeks. acetonitrile, the three amine analytes displayed more rapid
60 | Anal. Methods, 2013, 5, 59–63 This journal is ª The Royal Society of Chemistry 2013
View Article Online
Fig. 4 Chromatographic separation of a standard solution showing peaks for (1) betaine, (2) sodium, (3) potassium, (4) ammonium, (5) carnitine, (6) TMA, (7) choline,
(8) magnesium and (9) calcium.
This journal is ª The Royal Society of Chemistry 2013 Anal. Methods, 2013, 5, 59–63 | 61
View Article Online
Fig. 5 Representative chromatogram of a premix sample showing peaks for (1) betaine, (2) carnitine and (3) choline.
Concentration
Analyte range (mg mL1) Straight line equation R LOD (mg kg1) LOQ (mg kg1)
Carnitine Carnitine
Choline spike Choline found Recovery spike found Recovery Betaine spike Betaine found Recovery
Sample Type (mg kg1) (mg kg1) (%) (mg kg1) (mg kg1) (%) (mg kg1) (mg kg1) (%)
Table 3 Repeatability and intermediate reproducibility data obtained from premix analyses (n ¼ 6)
Liquid premix 523–22 700 3.9–5.0 4.4–5.7 0–1500 3.4–4.9 4.6–9.3 0–12 500 4.5–7.8 5.9–8.5
Solid premix 230–500 000 3.9–7.7 5.5–8.1 0–100 000 5.4–6.8 6.6–7.9 0–300 000 3.1–9.4 5.2–8.8
contained only one or two of the three analytes, and these products summarized in Table 2. Spike recoveries ranged from 92 to 98%, 91
were chosen so as to cover a representative concentration range of to 99% and 94 to 103% for betaine, carnitine and choline, respec-
the analytes, from low (<200 mg kg1) to medium (200–5000 mg tively, with RSDs less than 10%. The results of the recovery assays
kg1) to high (>5000 mg kg1). Three replicates of each sample with demonstrated that no signicant loss of analytes occurred during
different analyte concentrations were performed and the results are the extraction process.
62 | Anal. Methods, 2013, 5, 59–63 This journal is ª The Royal Society of Chemistry 2013
View Article Online
The RSD values obtained from repeatability tests using nine 8 D. J. Bindel, E. C. Titgemeyer, J. S. Drouillard and S. E. Ives, J.
premixes were 2.5%, 5.4% and 2.1% for betaine, carnitine and Anim. Sci., 2005, 83, 1625–1630.
choline, respectively, while the intermediate reproducibility RSD 9 R. G. Twibell and P. B. Brown, J. Nutr., 2000, 130, 95–99.
values for these same analytes were 4.7%, 3.5% and 2.4% (Table 3). 10 K. Q. Owen, J. L. Nelssen, R. D. Goodband, M. D. Tokach and
K. G. Friesen, J. Anim. Sci., 2001, 79, 1509–1515.
11 R. H. Greenwood, E. C. Titgemeyer, G. L. Stokka,
4 Conclusions J. S. Drouillard and C. A. Loest, J. Anim. Sci., 2001, 79, 254–260.
A simple and efficient IC method using non-suppressed detection 12 B. V. Lawrence, A. P. Schinckel, O. Adeola and K. Cera, J.
for the simultaneous determination of carnitine, choline and Anim. Sci., 2002, 80, 475–482.
betaine was developed. Aer extraction, the total run time of this 13 Y. Z. Wang, Z. R. Xu and J. Feng, Anim. Feed Sci. Technol.,
new method is only 15 min, making it signicantly faster than 2004, 116, 151–159.
existing assay techniques for the same analytes. This new method 14 D. C. Woollard and H. E. Indyk, J. AOAC Int., 2000, 83, 131–
also offers a high degree of specicity and is therefore well suited for 138.
the routine determination of these analytes in premixes. 15 J. Galbán, O. Sánchez-Monreal, Y. Andreu, S. de Marcos and
Published on 21 November 2012. Downloaded on 11/14/2018 2:13:17 AM.
This journal is ª The Royal Society of Chemistry 2013 Anal. Methods, 2013, 5, 59–63 | 63