0% found this document useful (0 votes)
118 views2 pages

OTDR Report: Job Info

The OTDR report summarizes fiber optic cable testing results. It tested a 3.4350 km span and found a span loss of 1.451 dB and average splice loss of 0.314 dB. The highest loss event was a non-reflective splice at 3.4350 km with a loss of 0.314 dB.

Uploaded by

sarah nesiana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
118 views2 pages

OTDR Report: Job Info

The OTDR report summarizes fiber optic cable testing results. It tested a 3.4350 km span and found a span loss of 1.451 dB and average splice loss of 0.314 dB. The highest loss event was a non-reflective splice at 3.4350 km with a loss of 0.314 dB.

Uploaded by

sarah nesiana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

OTDR report

Job info
Job ID : Reason :
Contractor : ANRITSU Operator A :
Customer : Operator B :
Test date : 07/04/2018 (08:46:57 PM GMT+7:00) File : susukan_ring22_07042018_1310...

Test and cable setup


Wavelength : 1310 nm (SM-9µm) Acq. time : 15 s
Filename : susukan_ring22_07042018_1310nm_007.... Pulse width : 50 ns
Hardware : (null) Helix factor : 0.00 %
Serial number : 6C00024872 Splice loss threshold : 0.250 dB
Software : N/A Reflectance threshold : -60.0 dB
Range : 10.2201 km End-of-fiber threshold : 3.000 dB
IOR : 1.467700
RBS : -78.50

Link measurements
Span loss : 1.451 dB Avg. splice loss : 0.314 dB
Span length : 3.4350 km Max. splice loss : 0.314 dB
Average loss : 0.422 dB/km Span ORL : ---

OTDR trace

dB

50.00

40.00
1

30.00

20.00

10.00

0.00
2 4 6 8 km

Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Launch Level 0.000 --- 0.000


Fiber Section (3.4350 km) 1.137 0.331 1.137
2 3.4350 Non-Reflective Event 0.314 1.451

Signature : _________________________ Date : 14/10/2018


EXFO Inc. Page 1 / 2
OTDR report
Events table Continued
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

Fiber Section (3.1713 km) 1.142 0.360 ---


6.6063 Reflective Event 28.257 -56.8 ---

Signature : _________________________ Date : 14/10/2018


EXFO Inc. Page 2 / 2

You might also like