DATASHEET FOR TEMPERATURE TRANSMITTER

FUEL GAS SKID


(MKS MODIFICATION)

1 TAG NO. (NOTE 5) REFER SHEET 2


2 SERVICE REFER SHEET 2
3 FUNCTION RECORD INDICATE CONTROL BLIND
4 OTHER GAUGE TEMPERATURE TRANSMITTER ENGINEERING UNIT : 0C
5 HOUSING MFR STD 316 SS COLOR : MFR STD
GENERAL

6 MOUNTING FLUSH SURFACE YOKE OTHER DIRECT MOUNT


7 ENCLOSURE CLASS GEN. PURPOSE WEATHER PROOF IP 56 EEx 'd'
8 INTRINSICALLY SAFE CERTIFIED HAZARDOUS AREA : IEC CLASS 1,ZONE 2, GR IIA
9 POWER SUPPLY 110 V 50 Hz OTHER 24 VOLTS , 2 WIRE (LOOP POWERED) AC
10 CHART STRIP ROLL FOLD CIRCULAR
11 CHART DRIVE SPEED : POWER :
12 SCALE TYPE : RANGE 1. 2.

13 TRANSMITTER OUTPUT 4-20 mA (NOTE 2) 21-103 kPa TYPE : SMART WITH HART PROTOCOL D
XMTR

14 FOR RECEIVER, SEE SPEC SHEET REF No. (NOT APPLICABLE)


15 ACCURACY ( OVERALL ) +/- 0.1% OF CALIBRATED SPAN

16 CONTROL MODES P=PROP(GAIN); i=INTEGRAL(AUTO RESET); D=DERIVATIVE(RATE)


17 SUB: s=SLOW;f=FAST: If Df P Pi PD PID Is Ds
18 OTHER
CTRL

19 ACTION ON MEASUREMENT INCREASE, OUTPUT : INCREASES DECREASES


20 AUTO MANUAL SWITCH NONE MFR STD OTHER
21 SET POINT ADJUSTMENT MANUAL EXTERNAL REMOTE OTHER
22 MANUAL REGULATOR NONE MFR STD OTHER
23 OUTPUT 4-20 mA 10-50 mA 21-103kPa(3-15psig) OTHER

24 ELEMENT TYPE (NOTE 2,3,5) RTD PLATINUM 100 NICKEL OTHER LENGTH TO SUIT WELL
25 ICE POINT N/A
26 PROCESS DATA REFER TO SHEET 2 AND 4
27 RANGE REFER TO SHEET 2 AND 4
ELEMENT

28 LEAD MFR STD POTTED HERMETICALLY SEALED


29 SHEATH (NOTE 4,5) SIZE: 6mm MATERIAL: SS316 * INSERTION: NOTE 5
30 CONNECTION (NOTE 2) TWO WIRE THREE WIRE FOUR WIRE
31 LEAD WIRE TRANSMITTER RECEPTICLE BAYONET LOCK
32 ELEVATION : - SUPPRESSION : -
33 THERMOWELL REFER TO SHEET 3
34

35 ALARM SWITCHES QUANTITY : FORM : RATING :


SWITCH

36 FUNCTION PRESSURE DEVIATION CONTACTS TO ON INC. MEAS.


37
38

39 PROTECTION OPEN CIRUIT PROTECTION UPSCALE PROTECTION ON LOSS OF INPUT


40 OTHER INTERNAL LCD INDICATOR
41 CABLE ENTRY (NOTE 8) ISO M20 X1.5 ( THROUGH CERTIFIED SS316 ADAPTER IF REQUIRED )
OPTIONS

42 OTHER REQUIREMENTS 1 THERMOWELL WAKE FREQUENCY CACULATION


43 2 THERMOWELL STRESS CALCULATION
44 3 2" PIPE MOUNTING ACESSORIES WHEREVER REQUIRED
45
46

47 MANUFACTURER Will be provided in detail design


OTHERS

48 MODEL NO. Will be provided in detail design


49
52

- For Additional notes and Details, refer to sheet 3 of 3


0 5-Apr-2015 Issued for Approval H.K. THAN T.H. QUAN P.X. VIET
REV DATE DESCRIPTION PREPARED CHECKED APPROVED CLIENT APPROVE
TRANSMIT
0C
OTHER
DIRECT MOUNT TO ELEMENT HEAD
I.S
S 1,ZONE 2, GR IIA, T3
DC

3.

RT PROTOCOL DIAGNOSTICS

SUIT WELL

ON INC. MEAS.

SS OF INPUT
LIENT APPROVED DATE
DATASHEET FOR TEMPERATURE TRANSMITTER
FUEL GAS SKID
(MKS MODIFICATION)

1. THERMOWELLS : INCLUDED NONE BY OTHERS

2. MATERIAL : SS316 OTHERS REFER TABLE BELOW

3. CONSTRUCTION : DRILLED BUILT-UP OTHERS NOTE 18

4. FLANGE SIZE : PIPE : DN 40


VESSEL : NA

5. LAP FLANGE/COVE FLANGE : INCLUDED BY OTHER

MATERIAL REFER TABLE BELOW


SIZE' AS PER THERMOWELL CONN. SIZE
RATING REFER TABLE BELOW
6. NOZZLE LENGTH :

PRESSURE PROCESS WELL DIM (FIG. 1)


FLUID
DENSITY CONNE./ LINE SIZE/ T/W
NO. TAG NO. P&ID VELOCITY
DESIGN OPERATING (Kg/m3) RATING SCHEDULE MATERIAL
(m3/h) L(mm) l2(mm)
Barg Barg (ANSI)

MKS-112-TS-TX1-
1 51TT-1511 85 55 64.37 61.54 600# DN50/ 160 (*) (*) SS 316
PID-10 (SHEET 2/2)

MKS-112-TS-TX1-
2 51TT-1512 35 31 89.13 44.45 300# DN50/ 160 (*) (*) SS 316
PID-10 (SHEET 2/2)

MKS-112-TS-TX1-
3 51TZT-1513 85 55 89.13 44.45 600# DN50/ 160 (*) (*) SS 316
PID-10 (SHEET 2/2)

MKS-112-TS-TX1-
4 51TZT-1517 35 31 89.13 44.45 300# DN50/ 160 (*) (*) SS 316
PID-10 (SHEET 2/2)
- For Additional notes and Details, refer to sheet 3 of 3
LAP
FLAGNGE NOTES REMARK
MATERIAL

NEW (PID REV 2)


EXTENSION OF GAS COMPRESSION CAPACITY Doc.
AT BLOCK 09-1. INSTALL TRAIN A ON MKS No.
MKS MODIFICATION Rev.
No.
DATASHEETS FOR TEMPERATURE TRANSMITTER Page 1 of 2

1 Tag Number Refer sheet 2


2 P&ID No. Pip. Class Refer sheet 2
General
3 Line No. Line size
Data
4
5
6 Temp. Min/Op/Max Refer sheet 2

Operating 7 Design pressure Refer sheet 2


Conditions 8 Design temperature Refer sheet 2
9 Refer sheet 2
10 TW Material Sensor Connection SS316 1/2" NPT-F
11 U-Length Refer sheet 2
Thermowell 12 Lag Extention VTC
13 Nozzle Length Refer sheet 2
14 Conn. Type Refer sheet 2
15 Type 3 wire PT-100 RTD (a = 0.00385)
16 Insulation Mineral Insulated
17 Immersion Length To suit the thermowell & nipple union
To suit the thermowell & nipple
18 Sensor Length Material VTC
union
19 Union Thread 1/2" NPT-M
20 Hazadous Area Classification Zone 2, GR IIA, T3
Temperature
21 Enclosure Protection Class IP 56 min, Ex"d"
Element &
Transmitter 22 Instrument Range Calibrated Range Refer sheet 2 Refer sheet 2
23 Element Burn-Out Protection Yes
24 Output signal 4-20 mA HART 2 wire
25 Accuracy Linearization 0.25% of Full Scale Yes
26 Power Supply 24 VDC, Loop Powered
27 Electric Connection 1/2" NPT-F
28 Transmitter housing material SS316
29 Indicator Yes (LCD)
Accessories
30
31 Manufacturer VTC
32 Model VTC
Purchase
33
34

Notes:
1. Vendor shall supply Brass/ 316SS plugs suitable for Class 1 Zone 2 IIA T3 hazadous area classification for spare cable entry.
2. Refer Doc No. "MKS-112-TS-IA2-SP-03 GENERAL INSTRUMENT SPECIFICATION" for more details.
3. Permanent fitted Stanless Steel Name Plate shall be provided with all standard specifications.

VTA = Vendor to Advice


VTC = Vendor to Confirm
PROCESS CONDITION
Nozzle ID &
CALIBRATION U-LENGTH PROCESS LINE Fluid OPER DESIGN DESIGN
No. TAG NO. SERVICE Length LOCATION P&ID NO. DENSITY VISCOSITY REMARKS
RANGE (°C) (mm) CONNECTION SIZE Velocity TEMP. PRESS. TEMP.
(mm) (kg/m3) (Cp)
(m/s) (°C) (BARG) (°C)
1 51TT-1511 HC GAS 0 +100 VTC 1-1/2" 600# RF 2" FUEL GAS SUPPERHEATER MKS-112-TS-TX1-PID-10 13.1 61.65 0.0130 22.37 85 0 - 190
2 51TT-1512 HC GAS 0 +100 VTC 1-1/2" 600# RF 4" FUEL GAS SUPPERHEATER MKS-112-TS-TX1-PID-10 9.08 26.52 0.0136 80 50 0 - 190
3 51TZT-1513 HC GAS 0 +100 VTC 1-1/2" 600# RF 4" FUEL GAS SUPPERHEATER MKS-112-TS-TX1-PID-10 7.67 43.56 0.0146 88.9 85 0 - 190
4 51TZT-1517 HC GAS 0 +100 VTC 1-1/2" 600# RF 4" FUEL GAS SUPPERHEATER MKS-112-TS-TX1-PID-10 9.08 26.52 0.0136 80 50 0 - 190

Doc. No
EXTENSION OF GAS COMPRESSION CAPACITY AT BLOCK 09-1.
INSTALL TRAIN A ON MKS
MKS MODIFICATION
Doc. No
EXTENSION OF GAS COMPRESSION CAPACITY AT BLOCK 09-1.
INSTALL TRAIN A ON MKS
MKS MODIFICATION
Rev. No

DATASHEETS FOR TEMPERATURE TRANSMITTER Page 2 of 2


DATASHEET FOR TEMPERATURE TRANSMITTER
FUEL GAS SKID
(MKS MODIFICATION)

NOTES :

2 The element shall be a 3 wire RTD type with class A resistance tolerance, Pt 100

3 RTD Shall be spring loaded type

4 RTD sheath O.D shall be 6.0mm ±0.1 mm to suit the thermowell before diameter of 6.5 mm ± 0.1mm (minimuim requirement)

5 The element length shall suit the thermowell insertion length

6 head extension, locknut, etc, shall be of 316 SS

7 The transmitter accuracy shall be ±0.1% of span

8 Cable entry shall be ISO M20 x 1.5. VENDOR shall provide certified plug/adaptor if required for unused entries.

9 Transmitter output shall be both analog and digital signal base on "HART' protocol. Transmitter configuration and calibration shall be p
a hand held programer

10 All transmitters shall be provided with 30 mm x 75 mm 316SS tag plate, inscribe with tag number, service and platform engraved or em
in 6 mm high and 0.3 mm deep bold characters. The tags shall be mounted on, or adjacent to the associated instrument and either fix
with stainless steel screws or attached with stainless steel wire.

11 Temprerature transmitters, together with the indicator shall be directly mouted to the sensors

12 VENDOR to confirm the diameter of the thermowell tip

13 VENDOR shall furnish thermowell vibration analysis calculation in according to ASME PTC 19.3. VENDOR shall veryfy the stem lengt
the fluid velocity indicated

14 VENDOR to ensure that the thermowell bore depth and extension match the stem length specified.

15 VENDOR to verify the thermowell strength analysis.

16 Thermowell shall meet the requirement of standard drawing S38.113-0, OR SS38. 114-0

17 Themowell shall be marked with Tag Number, Size, Rating, Material and Cast No.

18 Tapered thermowell construction shall be used for all piping class

19 Vendor shall perform 5-point calibration test at the factory and shall be witnessed by Purchaser's representative.

20 All SIS transmitters shall be TUV-approved only and meet the SIL 2 Safety Application requirements certified to IEC 61508 with Hardw
Tolerance (HFT = 0) and Safety Fault Fraction (SFF) above 90%. VENDOR to submit the EXIDA, TUV or third party report during bidd

21 The preferred method of protection instruments enclosure shall be Instrinsically Safe (IS) EEX"i" type -certified in accordance with IEC
Hazardous area certification shall be in accordance with ATEX, by approved bodies such as
22 CENELEC, BASEEFA, etc

23 All Transmitters shall meet 5 years of stability and 2 years warranty on reliability and operability.

24 RTD shall not be used with high vibration services


bration shall be posible from

m engraved or embossed
ment and either fixed

fy the stem length against

61508 with Hardware Fault


eport during bidding exercise.

ordance with IEC standard.