Emerson manufactures line and load reactors for use with electronic variable speed drives. Line reactors help meet harmonic distortion standards, improve current balance, and protect equipment from power surges. Load reactors reduce motor winding effects from high wiring capacitance and voltage changes. The document provides application details and selection charts for Emerson Commander line and load reactors for various motor powers at 230V and 460V.

Uploaded by

bakien-can
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views

Reactors

Emerson manufactures line and load reactors for use with electronic variable speed drives. Line reactors help meet harmonic distortion standards, improve current balance, and protect equipment from power surges. Load reactors reduce motor winding effects from high wiring capacitance and voltage changes. The document provides application details and selection charts for Emerson Commander line and load reactors for various motor powers at 230V and 460V.

Uploaded by

bakien-can
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

www.emersonct.

com

800-893-2321

Line and Load Reactors


Line reactors (sometimes called line chokes) are a
common power accessory for electronic variable speed
drives. These components add an extra margin of
protection for AC and DC drives. Load reactors are also
used on the output of AC Drives to reduce the effects of
high motor wiring capacitance and to “soften” the dv /
dt (high rates of change of voltage) applied to the motor
windings.

Voltage 600 VAC maximum


Ambient Temperature 40°C (104°F)
Overload 200% for 3 minutes
Standards CSA
UL / cUL Recognized

Reactors in AC drive applications:


• Help meet IEEE 519 criteria by reducing harmonic
distortion of the input line current.
• Improve input line current balance.
• Reduce nuisance drive over-voltage trips caused
by transient voltage spikes and power line notches.
• Protect input rectifiers from in-rush current caused
by sudden power line surges and sags.
• Extend the life of the DC bus capacitor bank by
reducing the internal heating caused by ripple
current.
• Protect motor windings from long lead effects
when used on the drive output.

Line Reactors in DC drive applications:


• Minimize crosstalk between multiple SCR drives by
reducing line notching and subsequent dv/dt
misfiring / bridge failures.
Order String
• Eliminate SCR failures caused by high dv/dt
levels associated with stiff or power factor xxx x – x – xxx – x
corrected power lines.
• Protect other line-powered sensitive electronic
C = Open Chassis
equipment by filtering electrical noise / interference E = Enclosed Chassis
caused by drives on the power line.
Accessories

Current Rating
Power

L = Low Impedance (3% Typical)


H = High Impedance (5% Typical)
Voltage: 2 = 230V, 4 = 460V, 5 = 575V
LR = Line Reactor
LDR = Load Reactor

427
www.emersonct.com

800-893-2321

Commander SK Line and Load Reactor Selection

Line Reactor Load Reactor

Input Line Reactor Output Load Reactor


Motor Power (HP) Order Code Current (A) Current (A)
Order Code Order Code
115 VAC 1Ø
0.33 SKA1100025 LDR2-L-004-X 4.2
0.5 SKA1100037 LDR2-L-004-X 4.2
230 VAC 1Ø
0.33 SKA1200025 4402-0224 6.5 LDR2-L-004-X 4.2
0.5 SKA1200037 4402-0224 6.5 LDR2-L-004-X 4.2
0.75 SKA1200055 4402-0225 15.1 LDR2-L-004-X 4.2
1.0 SKA1200075 4402-0225 15.1 LDR2-L-006-X 6
1.5 SKBD200110 4402-0225 15.1 LDR2-L-006-X 6
2.0 SKBD200150 4402-0226 26.2 LDR2-L-010-X 9.6
3.0 SKCD200220 4402-0226 26.2 LDR2-L-015-X 15.2
3.0 SKDD200300 4402-0226 26.2 LDR2-L-015-X 15.2
230 VAC 3Ø
1.5 SKBD200110 LR2-L-010-X 9.6 LDR2-L-006-X 6
2 SKBD200150 LR2-L-015-X 15.2 LDR2-L-010-X 9.6
3 SKCD200220 LR2-L-022-X 22 LDR2-L-015-X 15.2
3.0 SKDD200300 LR2-L-015-X 15.2 LDR2-L-015-X 15.2
5 SKD3200400 LR2-L-022-X 22 LDR2-L-022-X 22
460 VAC 3Ø
0.5 SKB3400037 LR4-L-003-X 3.4 LDR4-L-003-X 3.4
0.75 SKB3400055 LR4-L-003-X 3.4 LDR4-L-003-X 3.4
1 SKB3400075 LR4-L-003-X 3.4 LDR4-L-003-X 3.4
1.5 SKB3400110 LR4-L-005-X 4.8 LDR4-L-003-X 3.4
2 SKB3400150 LR4-L-008-X 7.6 LDR4-L-005-X 4.8
3 SKC3400220 LR4-L-011-X 11 LDR4-L-008-X 7.6
5 SKC3400400 LR4-L-014-X 14 LDR4-L-014-X 14
7.5 SKD3400550 LR4-L-014-X 14 LDR4-L-014-X 14
10 SKD3400750 LR4-L-021-X 21 LDR4-L-021-X 21
Accessories
Power

428
www.emersonct.com

800-893-2321

Line and Load Reactor Selection


DRIVE ORDER CODE LEGEND
w=SL for Commander SL, or SK for Commander SK
y= SK for Commander SK, or
CGP for Commander GP20, or SP for Unidrive SP
Line Reactor Load Reactor
z= CGP for Commander GP20, or SP for Unidrive SP

Motor Power (HP) Drive Input Line Reactor Current Output Load Reactor Current (A)
Normal Duty Heavy Duty Order Code Order Code (A) Order Code
230 VAC 3Ø
1.5 1 z1201 LR2-L-010-X 9.6 LDR2-L-006-X 6
2 1.5 z1202 LR2-L-015-X 15.2 LDR2-L-010-X 9.6
3 2 z1203 LR2-L-022-X 22 LDR2-L-010-X 9.6
4 4 z1204 LR2-L-022-X 22 LDR2-L-015-X 15.2
5 4 y2201 LR2-L-022-X 22 LDR2-L-022-X 22
7.5 5 y2202 LR2-L-028-X 28 LDR2-L-022-X 22
10 7.5 y2203 LR2-L-042-X 42 LDR2-L-028-X 28
15 10 y3201 LR2-L-054-X 54 LDR2-L-042-X 42
20 15 y3202 LR2-L-068-X 68 LDR2-L-054-X 54
25 20 y4201 LR2-L-080-X 80 LDR2-L-077-X 77
30 25 y4202 LR2-L-080-X 80 LDR2-L-096-X 96
40 30 y4203 LR2-L-104-X 104 LDR2-L-130-X 130
50 40 y5201 LR2-L-130-X 130 LDR2-L-130-X 130
60 50 y5202 LR2-L-154-X 154 LDR2-L-154-X 154
460 VAC 3Ø
1.5 1 z1401 LR4-L-005-X 4.8 LDR4-L-003-X 3.4
2 2 z1402 LR4-L-008-X 7.6 LDR4-L-005-X 4.8
3 3 z1403 LR4-L-008-X 7.6 LDR4-L-008-X 7.6
5 4 z1404 LR4-L-011-X 11 LDR4-L-008-X 7.6
5 5 z1405 LR4-L-011-X 11 LDR4-L-011-X 11
7.5 5 z1406 LR4-L-014-X 14 LDR4-L-011-X 11
10 10 y2401 LR4-L-021-X 21 LDR4-L-021-X 21
15 10 y2402 LR4-L-027-X 27 LDR4-L-021-X 21
20 15 y2403 LR4-L-034-X 34 LDR4-L-034-X 34
20 20 y2404 LR4-L-034-X 34 LDR4-L-034-X 34
25 25 y3401 LR4-L-040-X 40 LDR4-L-040-X 40
30 30 y3402 LR4-L-052-X 52 LDR4-L-052-X 52
40 30 y3403 LR4-L-065-X 65 LDR4-L-065-X 65
50 50 y4401 LR4-L-065-X 65 LDR4-L-077-X 77
60 60 y4402 LR4-L-096-X 96 LDR4-L-096-X 96
75 75 y4403 LR4-L-124-X 124 LDR4-L-124-X 124
100 100 y5401 LR4-L-156-X 156 LDR4-L-156-X 156
150 125 y5402 LR4-L-156-X 156 LDR4-L-180-X 180
150 150 y6401 LR4-L-240-X 240 LDR4-L-240-X 240
200 150 y6402 LR4-L-302-X 302 LDR4-L-240-X 240
575 VAC 3Ø
5 3 y3501 LR5-L-009-X 9 LDR5-L-006-X 6.1
5 5 y3502 LR5-L-009-X 9 LDR5-L-006-X 6.1
7.5 5 y3503 LR5-L-011-X 11 LDR5-L-009-X 9
10 7.5 y3504 LR5-L-017-X 17 LDR5-L-011-X 11
15 10 y3505 LR5-L-022-X 22 LDR5-L-017-X 17
20 15 y3506 LR5-L-027-X 27 LDR5-L-022-X 22
25 20 y3507 LR5-L-027-X 27 LDR5-L-027-X 27
30 25 y4603 LR5-L-041-X 41 LDR5-L-041-X 41
40 30 y4604 LR5-L-041-X 41 LDR5-L-041-X 41
Accessories

50 40 y4605 LR5-L-052-X 52 LDR5-L-052-X 52


Power

60 50 y4606 LR5-L-062-X 62 LDR5-L-062-X 62


75 60 y5601 LR5-L-099-X 99 LDR5-L-099-X 99
100 75 y5602 LR5-L-099-X 99 LDR5-L-099-X 99
125 100 y6601 LR5-L-144-X 144 LDR5-L-144-X 144
150 125 y6602 LR5-L-192-X 192 LDR5-L-192-X 192

For larger horsepower Unidrive SP drives please consult factory.