FS Series: DIN Size W48×H48mm 8pin Plug Counter
FS Series: DIN Size W48×H48mm 8pin Plug Counter
▣Specifications
※A blacked( ) item is upgraded function.
Single preset FS4A
Model
Indication type FS5B
Digit 4 5
Digit size W4×H8mm
Power supply 100-240VAC 50/60Hz, 12-24VDC(Option)
Allowable voltage range 90 ~ 110% of rated voltage
Power consumption 4VA
Max. counting speed for
Selectable 1cps/30cps/2kcps/5kcps by internal DIP switch
CP1, CP2
A-53
8 Pin Plug Counter
▣Connections
(A)
Counter
(B)
Timer
(C)
Temp.
controlle
(D)
Power
controlle
▣Dimensions
lBracket lPannel cut-out (E)
Panel
Min.55 meter
(F)
Tacho/
Speed/
Pulse
M in.62 meter
(G)
Unit:mm Display
unit
lSocket (Accessory)
(H)
Unit:mm Unit:mm Sensor
controlle
(I)
Proximit
sensor
(J)
▣Input connections Photo
electric
sensor
◎Input logic : No-voltage input(NPN)
lSolid-state input(Standard input sensor :NPN output type sensor) lContact input
Sensor Counter Counter (K)
Brown Pressur
sensor
Black
Inner Inner Inner
circuit circuit circuit (L)
Rotary
Blue
encoder
A-54
FS Series
◎Input & output connections
Br own
Black
Blue
Down mode
Up mode
lMemory retention
Function
Power reset
(Non memory)
Memory
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
RESET RESET RESET RESET
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3
+ + + + TIM E
+ + + + TIME
+ + + + TIME
+ + + + TIME
A-55
8 Pin Plug Counter
▣Counting operation of indication mode(Indication model)
lUp input mode lDown intput mode (A)
Counter
(B)
Timer
-Max.display value
Output mode
Up mode Down mode Operation after count up (D)
(SW1) Power
controlle
(F)
Reset Reset Tacho/
Preset Pr eset The display value and Self- Speed/
8 holding output are held until Pulse
meter
reset signal is applied.
Output Output
(G)
Display
Reset Reset unit
Reset Reset
Preset Pr eset The display value is held until (I)
8 output is OFF then returns to Proximit
reset start status. sensor
Output Output
(J)
Reset Reset Photo
electri c
Pr eset
8 Preset The display value continues sensor
U Up input mode
Reset Reset
-Output is ON when
Preset Pr eset
8 (Display value) ≥ (Preset value)
U Down input mode
-Output is ON when
Output Output (Display value) ≤ (Zero)
A-56
FS Series
▣Proper usage
◎Reset function ◎Error display
lReset Error signal Error description Returning method
In case of changing the input mode after supplying Change the set value
Zero set state
the power, please take a external reset or manual to non zero state
reset. If reset is not executed, the counter will ※When Error is displayed, the output continues OFF state.
be working as previous mode. ※There is no Error function in the indication type.
* 0 0 0 0
+ + + +
TI ME
** ** ◎Power
*Please make duty ratio(ON/OFF) 1:1. The inner circuit voltage starts to rise up for the first
** Min. signal width 1cps : Max. 0.5sec 100ms after power on, the input may not work at this
30cps : Max.16.7ms time. And also the inner circuit voltage drops down
2kcps : Max. 0.25ms for the last 500ms after power off, the input may not
5kcps : Max.0.1ms work at this time.
◎Max. counting speed ON
P ower
This is respond speed per 1sec. when the duty ratio OFF
100ms 500ms
(ON/OFF) of input signal is 1:1. The unstable time
against the input signal.
If duty ratio is not 1:1, the respond speed will be
getting slow against input signal and also the width
between ON and OFF should be over min. signal
width and also one of ON width and OFF width is
Under min. signal width, this product may not
response.
Ta Tb Width of Ta(ON) and Tb(OFF)
must be larger than Min. signal
width.
Max.counting speed is 1/2 value
3×Ta of catalog spec. when duty rate
is 1:3.
It can not respond because Max.
signal width(1a) is little.
A-57