Structure Checks
Structure Checks
width 0.6 m
depth 4m
a 0.06 m
As 0.002039998 m2
M 432.9296262 kN m/m
spacing 0.139215828 5.479534975 inches c/c
Applied
Pw 78.4 kN/m
For soil
Width 0.3 m
Depth 3m
a 0.03 m
ø 32 degree
Ka 0.470080736
Ps 38.0765396
Mapplied 60.92246336 Areq 0.000574
As min 0.00135 M 143.2489
As used 0.00135
spacing 0.286666667 11.2832
200/fy 0.003333333
U.S. rebar size chart
Linear Mass
Imperial "Soft" Density Nominal diameter
metric
bar size size lb⁄ft (kg/m) (in) (mm)
0.250
#2 #6 0.167 0.249 = 1⁄4 6.35
0.375
#3 #10 0.376 0.561 = 3⁄8 9.525
0.500
KN/m2 #4 #13 0.668 0.996 = 4⁄8 12.7
0.625
KN/m2 #5 #16 1.043 1.556 = 5⁄8 15.875
0.750
#6 #19 1.502 2.24 = 6⁄8 19.05
0.875
#7 #22 2.044 3.049 = 7⁄8 22.225
#8 #25 2.67 3.982 1 25.4
#9 #29 3.4 5.071 1.128 28.65
#10 #32 4.303 6.418 1.27 32.26
#11 #36 5.313 7.924 1.41 35.81
#14 #43 7.65 11.41 1.693 43
#18 #57 13.6 20.284 2.257 57.3
#18J 14.6 21.775 2.337 59.4
Nominal area
(in²) (mm²) m2
0.05 32 0.000032
0.11 71 0.000071
Heel design
Wfound 51.98838 KN /m
Mfound 43.93018 KN m/m
Vu 67.58489 KN Shear design is not required
ɸVc 695.8052 Spacing
Vs 320.1574
spacing 7.114608
spacing 0.15
spacing 0.6
Spacing needed 0.1
Default values
0.25
0.25 T1
0.5
0.43
lb/f3
lb/f3
lb/f3
L2 T2 L1
Movr 33.27241
Mres 37.6826
If a=l/3
qmax 118.1855
qmin 0
if a<l/3
qmax 104.4054
qmin 0
T3
Not safe against sliding
Opposite Arm
Asmin 0.21 in2/f
Spacing 11.1 inches
bars
U have to put data only in pink cells
6.59050985 inches
B 2.5
Isolated footing Column
Combined footing
fy 60 ksi 60000
fc 3 ksi 3000
C1 C2
W 12 inches 12
H 12 inches 12
D.L 24.7 kips 24.7
L.L 4.25 kips 4.25
ɣs 100 lb/cf
ɣc 150 lb/cf
Bottom of the footing below ground level 4f
Bearing capacity of soil 2000 psf
C1 acting at distance from lef side X1 6 inches
C2 acting at distance from lef side X2 168 inches
Assume depth of pad 18 inches
Resultant acting on 87 inches 7.25
qe 1525 psf
Area required 37.96721311 sq-in
Bearing Pressure for Strength Design 1.91955095
Soil pressure 13.91674439 f
Effective depth d 14.5 inches
Max shear from diagram 91 kips
Vu 74.18393387 kips
Checking for depth 10.37859872 inches Depth OK
psi
psi Interior
edge
corner
ksf
0.012195 inches
16 " column
9' x 9' footing
0.75
psi
psi
psf
f
ksf
f
psi
psi
inches
inches
kips
kips
f
Depth OK
e the perimeter is
Jabori-HPP-Type-IV Residential building
fc 3 ksi
fy 40 ksi
Lb 18.25 f Lb>La
La 12.83 f
m 0.70
hmin 4.14 5 inches providing 5 " slab
Effective depth 3.5 inches
Tile thickness 0.33 inches
Mud thickness 3 inches
D.L slab 0.10 ksf
F.D.L 0.12 ksf
L.L 0.04 ksf
F.L.L 0.06 ksf
Wu 0.18 ksf
Coefficient method Case-8
Ca neg 0.081
Cb neg 0.019
Ca pos DL 0.046
Cb pos DL 0.011
Ca pos LL 0.057
Cb pos LL 0.014
0 0
1.809091 10
0 10
-2.21111 10
U have to put data in pink cells only
Shear design
V 15.945 Kips
Vx 14.1511875 Kips
Vc 0 Kips
Vx 14.1511875 Kips
V 15.945 Kips
ɸVc 11.8308072421 Kips 2 legged # 3 bar @ 6 inches c/c
Vs 11.1375 Kips
Spacing 5.0625 inches
15.945 0
14.1511875 0.84375
0 10.375
-14.1511875 14.15625
-15.945 15
0 0
10.375 59.79375
15 0
T-beam
C/C distance between beam 5
f
Span of beam 50 f
bw 20 inches
t 0.667 inches
h 40 inches
d 37 inches
be (1) 30.672 inches
be (2) 150 inches
be (3) 104 inches
be req 30.672 inches
wu 5.15 k/f
Mu 19312.5 kip-in
As min (1) 3.0398601942 sq-in
As min (2) 3.7 sq-in
a=t 0.667 inches
As 14.6307483216 sq-in
a 7.4824574353 inches
where a = aweb
Shear design
V 128.75 kips
Vx 112.870833333 kips
ɸVc 60.7972038831 kips
1/2 ɸVc 30.3986019415 kips
SF
20
15.945
15
1
14.1511875
10 2
5 3
4
0 0 5
0 2 4 6 8 10 12 14 16 Linear (5)
-5
-10
-14.1511875
-15.945
-15
-20
B.M
70
59.79375
60
50
40 B.M
30
20
10
0 0 0
0 5 10 15 20 25
40 B.M
30
20
10
0 0 0
0 5 10 15 20 25
Span 45 f
Road width curb to curb 9.5 f
fc 4000 psi
fy 60000 psi
Curb width 15 inches
Total width of bridge 12
Minimum thickness of deck 26.4 inches
Slab load 0.275 ksf
Wearing surface 0.035 ksf
Slab moments 69.609375 kip-f/f
Wearing surface moments 8.859375 kip-f/f
Live load moments
M truck 350 kip-f
M tandem 372 kip-f
M lane 98 kip-f
kip-f
Using greater load 372 kip-f
M LL+IM 592.76 kip-f
Design Lane width “E” for interior strip:
For single lane loaded E (inches) = 10.0 + 5.0 √ (L1W1)
L1 45 f
W1 12 f
E 10.5157916989 f
Design Lane width “E” for interior strip:
For multilane loaded: E (inches) = 84 + 1.44√ (L1W1) ≤ W1/NL
E (inches) = 84 + 1.44√ (L1W1) ≤ W1/NL
L1 45 f
W1 12 f
E 9.7885480093 f
W1/NL 12
Taking least E 9.7885480093 f
Interior Strip Moment (per foot) 60.5564787994 kip-f/f
Mu (interior strip)= 1.05 [1.25MDC + 1.5MDW + 1.75MLL+IM (per foot)] 2599.0602013 kip-in/f
22 inches
Tendam load
http://bendingmomentdiagram.com/solve/
Lane load
2570.82564375 kip-in/f
Desig not ok
% of Main reinf
18 in c/c
Design not ok
Slab information
Width 25 f
Length 28 f
m 0.8928571429
Thickness 6 inches
D.L of slab 0.1266666667 ksf
Live load on slab 0.015 ksf
Wu slab 0.176 ksf
coefficent for longer walls 0.6
Load of slab on longer wall 0.0528 ksf
Load of slab on shorter wall 0.0352 ksf
Beam Information
W 1f
D 1.5 f
D.L of beam 0.225 k/f
Factor.L of beam 0.27 k/f
26.9 KN T=Hw*D*rw/2
Max Hoop stressess at the
bottom of tank
Area of steel 179.2 mm2 As=T/allowablestress
Minimum steel req 495 mm2 As=.45%b*h
Spacing for #4 bar (horizontal bars) 260.6 mm c/c Ab=129 mm2
Without edge
Edge beam beams
without drop
Drop panel panels
ln 22.3 f
Min thickness of slab
Without edge beams with/without edge beam
With edge beams
without drop panel
with drop panel