Data Sheet
Data Sheet
Data Sheet
Key features
• Invertible analog input signal: 0—10 / 10—0 VDC or 0—20 / 20—0 mA
• Analog input (normal or logic functionality - only for the timer start)
• 1 low voltage supply output (+12 VDC / 1 mA) for external 10 kΩ potentiometer
Technical specifications
Power supply, Us 230 VAC ±10 % / 50—60 Hz
Modbus registers
Standards
The Sensistant Modbus configurator allows you to easily
• Low Voltage Directive 2014/35/EC monitor and/or configure Modbus parameters. Designed to
be used in combination with PDM or DPOM modules.
• EMC Directive 2014/35/EC The parameters of the unit can be monitored / configured
through the 3SModbus software platform. You can download
• WEEE Directive 2012/19/EC it from the following link:
https://www.sentera.eu/3SMCenter/Index/ENG/
• DIN rail EN 50022
ou can find register maps in the mounting instructions.
Y
Download them from:
• RoHs Directive 2011/65/EC https://www.sentera.eu/Product/Index/
Settings
1 - DIP switch settings
ON – Descending mode:
5 Ascending / descending
ON
10—0 VDC / 20—0 mA
input mode selection
7 (DIP switch, position 1) OFF – Ascending mode:
4 1 2 3 4
0—10 VDC / 0—20 mA
3 ON ON - enabled
OFF level selection
(DIP switch, position 2)
1 2 3 4 OFF - disabled
Ai Analog input 0—10 VDC / 0—20 mA Off-level value from 0 VDC (left) to
4 VDC (right) in voltage mode
GND Ground
VR3 Off-level value from 0 mA (left) to
A Modbus RTU (RS485) signal A 8 mA (right) in current mode
5 - Off level trimmer Descending mode
/B Modbus RTU (RS485) signal /B
Off-level value from 10 VDC (left) to
Connections Cable cross section: max. 2,5 mm2 6 VDC (right) in descending and
voltage mode
Caution: If an AC power supply is used with any of the units on a Modbus network, the GND
terminal should NOT BE CONNECTED to other units on the network or via the CNVT-USB-RS485 Off-level value from 20 mA (left) to
converter. This may cause permanent damage to the communication semiconductors and / or 12 mA (right) in descending and
the computer! current mode
6 - Modbus communication
Blinking green Transmitting / receiving
indication
*
indicates closed position of the jumper.
Operational diagrams
Operating modes
Off level disabled Off level enabled
75 75
70
70
Umin
Umin 2 range Umin
range Umin 2
30
30
0
10 VDC Ai,
0 20 mA [VDC] /
10 VDC Ai, Off level
Off level range
range [mA]
20 mA [VDC]/[mA]
Ai (
Descending mode calculation formula Uout = Umax - Aimax Umax - Umin) Descending calculation formula
Ai - Off level
Uout = Umax - Aimax (Umax - Umin)
- Off level
Ai (
Uout = Umin + Aimax Umax - Umin)
Ascending mode calculation formula Ai - Offlevel
Ascending calculation formula Uout = Umin + Aimax (Umax - Umin)
- Offlevel
100 100
Ai, 10 VDC / 20 mA Ai, 10 VDC / 20 mA
Umax
range
0 VDC / 0 mA 0 VDC / 0 mA
range
75 75
70 70
2 1
range
range
Umin
Umin
Umin
Umin Umin
range Umin OFF Level
Ai, 10 VDC / 20 mA range
1 0 VDC / 0 mA
30 30
Ai, 10 VDC / 20 mA
2 0 VDC / 0 mA
0 0
Kick starttime
Kickstart time t [s] Soft starttime
Softstart time t [s]
Kick start & off level Soft start & off level
Uout,[%]
Uout, [%]
100 100
Ai, 10 VDC / 20 mA Ai, 10 VDC / 20 mA
Umax
range
Umax
range
75 75
70 70
2 1
range
range
Umin
Umin
30 30
Ai, 10 VDC / 20 mA
1 Ai, 10 VDC / 20 mA
2 0 VDC / 0 mA
0 VDC / 0 mA 0
0
Soft start time
Softstart time t [s]
Kick start time
Kickstart time t [s] Softstart time
1 - Descending mode Note: You can find more details about the control functionalities of MVS in our mounting instructions published on our website.
Please follow the link: https://www.sentera.eu/Product/Index/ENG/?ArticleID=1330055
2 - Ascending mode
Operational diagrams
Timer mode Logic mode
Kick start enabled Switch control signal
Remote
Uout, [%] Switch,
[VDC]
100
5 VDC
Umax
range Voltage
amplitude
75 range
2,5 VDC
0
t, [s]
0
Kick start time Operation timer Controller t [s]
is off
Stand-by Operate
ON OFF ON OFF t
ON OFF ON OFF t
Soft
start Soft
start
t
Holding Holding t Holding Holding
register register register register
18 18 18 18
Timer
Timer
t
Holding t Holding Holding
register register register
21 21 21
Output
Umax Output
Umax
L W
H H
MVS-1-60CDM MVS-1-15CDM
MVS-1100CDM MVS-1-30CDM