Stenner Classic Series Installation Instructions
Stenner Classic Series Installation Instructions
Stenner Classic Series Installation Instructions
I N S TA L L AT I O N M A N U A L
Metering Pumps Manufactured Since 1957
Table of Contents
Warranty and Service Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Pump Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15 Materials of Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Accessory Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-26 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27-30 Tube Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-35 Motor exploded view and parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-38 Feed Rate Control exploded view and parts . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40 Pump Head exploded view and parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41-44 Pump Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 For Your Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
CIMM06
2 www.stenner.com
Safety Information
Warns about hazards that CAN cause death, serious personal injury, or property damage if ignored.
HAZARDOUS VOLTAGE: DISCONNECT power cord before removing motor cover for
service. Electrical service by trained personnel only.
EXPLOSION HAZARD:
This pump is not explosion proof. Do Not install or operate in an explosive environment.
www.stenner.com
Safety Information
PLUMBING:
continued
This is the safety alert symbol. When displayed in this manual or on the equipment, look for one of the following signal words alerting you to the potential for personal injury or property damage.
Warns about hazards that WILL or CAN cause minor personal injury or property damage if ignored.
Chemical feed pump installation must always adhere to your local plumbing codes and requirements. Be sure installation does not constitute a cross connection. Check local plumbing codes for guidelines.
PUMP SUITABLE FOR USE OUTDOORS when installed with a Stenner Rain Roof Part No. MP90000. Electrical installation should adhere to all national and local codes. Consult a licensed professional for assistance with proper electrical installation. Removing power from pool/spa recirculation pump must also remove power from pump. The use of an auxiliary safety device (not supplied), such as a flow switch or sensor, is recommended to prevent feed pump operation in the event of a recirculation pump failure or if flow is not sensed. Point of chemical injection should be beyond all pumps, filters, and heaters. PUMP INTENDED FOR INDOOR USE. Cette pompe est prvue pour utilisation lintrieur.
Pump Identification
Identify your pump using the label on the box or the pump.
Box Label
85MHP5 02010503943 120 5/18.9 Adjustable 5/18.9 Ajustable 5/18.9 100/6.9 1/4" White 1/4" Blanco 85MJH1A1STAA
Model Serial Number Voltage Maximum Output per Day Maximum Operating Pressure Suction/Discharge Tubing Item Number for Placing Order
www.stenner.com
Pump Identification
continued
Pump Label
STENNER PUMP COMPANY
Item Number for Placing Order Voltage Maximum Output per Day Serial Number
Outputs 45 series
The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. (20:1 Turndown Ratio)
Approx. Outputs @ 60 Hz
Single Head Model Adjustable 45MHP2* 45M1 Fixed Output 45MPHP2* 45MP1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute
Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute
100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar
#1 #1 #1 #1 #2 #2 #2 #2 #7 #3 #7 #3 #4 #4 #5 #5
0.2 to 3.0 0.2 to 3.0 3.0 3.0 0.5 to 10.0 0.5 to 10.0 10.0 10.0 1.1 to 22.0 1.1 to 22.0 22.0 22.0 1.7 to 35.0 35.0 2.5 to 50.0 50.0
0.8 to 11.4 0.8 to 11.4 11.4 11.4 1.9 to 37.9 1.9 to 37.9 37.9 37.9 4.2 to 83.3 4.2 to 83.3 83.3 83.3 6.4 to 132.5 132.5 9.5 to 189.3 189.3
0.01 to 0.13 0.01 to 0.13 0.13 0.13 0.02 to 0.42 0.02 to 0.42 0.42 0.42 0.05 to 0.92 0.05 to 0.92 0.92 0.92 0.07 to 1.46 1.46 0.10 to 2.08 2.08
0.03 to 0.48 0.03 to 0.48 0.48 0.48 0.08 to 1.58 0.08 to 1.58 1.58 1.58 0.18 to 3.47 0.18 to 3.47 3.47 3.47 0.27 to 5.52 5.52 0.40 to 7.89 7.89
0.02 to 0.27 0.02 to 0.27 0.27 0.27 0.04 to 0.89 0.04 to 0.89 0.89 0.89 0.10 to 1.96 0.10 to 1.96 1.96 1.96 0.15 to 3.11 3.11 0.22 to 4.44 4.44
0.56 to 7.92 0.56 to 7.92 7.92 7.92 1.32 to 26.32 1.32 to 26.32 26.32 26.32 2.92 to 57.85 2.92 to 57.85 57.85 57.85 4.44 to 92.01 92.01 6.60 to 131.46 131.43
0.6 to 9.1 0.6 to 9.1 9.1 9.1 1.5 to 30.3 1.5 to 30.3 30.3 30.3 3.3 to 66.6 3.3 to 66.6 66.6 66.6 5.1 to 106.0 106.0 7.6 to 151.4 151.4
0.03 to 0.38 0.03 to 0.38 0.38 0.38 0.06 to 1.26 0.06 to 1.26 1.26 1.26 0.14 to 2.78 0.14 to 2.78 2.78 2.78 0.21 to 4.42 4.42 0.32 to 6.31 6.31
0.31 to 6.32 0.31 to 6.32 6.32 6.32 1.04 to 21.04 1.04 to 21.04 21.04 21.04 2.29 to 46.25 2.29 to 46.25 46.25 46.25 3.54 to 73.61 73.61 5.28 to 105.14 105.14
Adjustable 45MHP10* 45M2 Fixed Output 45MPHP10* 45MP2 Adjustable 45MHP22* 45M3 Fixed Output 45MPHP22* 45MP3 Adjustable 45M4 Fixed Output 45MP4 Adjustable 45M5 Fixed Output 45MP5
*pump supplied with injection check valve for 26-100 psi applications
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
www.stenner.com
Outputs 85 series
The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. (20:1 Turndown Ratio)
Approx. Outputs @ 60 Hz
Single Head Model Adjustable 85MHP5* 85M1 Fixed Output 85MPHP5* 85MP1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute
Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute
100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar
#1 #1 #1 #1 #2 #2 #2 #2 #7 #3 #7 #3 #4 #4 #5 #5
0.3 to 5.0 0.3 to 5.0 5.0 5.0 0.8 to 17.0 0.8 to 17.0 17.0 17.0 2.0 to 40.0 2.0 to 40.0 40 40 3.0 to 60.0 60.0 4.3 to 85.0 85.0
1.1 to 18.9 1.1 to 18.9 18.9 18.9 3.0 to 64.4 3.0 to 64.4 64.4 64.4 7.6 to 151.4 7.6 to 151.4 151.4 151.4 11.4 to 227.1 227.1 16.3 to 321.8 321.8
0.01 to 0.21 0.01 to 0.21 0.21 0.21 0.03 to 0.71 0.03 to 0.71 0.71 0.71 0.08 to 1.67 0.08 to 1.67 1.67 1.67 0.13 to 2.5 2.50 0.18 to 3.54 3.54
0.05 to 0.79 0.05 to 0.79 0.79 0.79 0.13 to 2.68 0.13 to 2.68 2.68 2.68 0.32 to 6.31 0.32 to 6.31 6.31 6.31 0.48 to 9.46 9.46 0.68 to 13.40 13.40
0.03 to 0.44 0.03 to 0.44 0.44 0.44 0.07 to 1.51 0.07 to 1.51 1.51 1.51 0.18 to 3.55 0.18 to 3.55 3.55 3.55 0.27 to 5.33 5.33 0.38 to 7.55 7.55
0.76 to 13.13 0.76 to 13.13 13.13 13.13 2.08 to 44.65 2.08 to 44.65 44.65 44.65 5.27 to 105.14 5.27 to 105.14 105.14 105.14 7.92 to 157.71 157.71 11.32 to 223.40 223.40
0.9 to 15.1 0.9 to 15.1 15.1 15.1 2.4 to 51.5 2.4 to 51.5 51.5 51.5 6.1 to 121.1 6.1 to 121.1 121.1 121.1 9.1 to 181.7 181.7
0.4 to 0.63 0.4 to 0.63 0.63 0.63 0.10 to 2.15 0.10 to 2.15 2.15 2.15 0.25 to 5.05 0.25 to 5.05 5.05 5.05 0.38 to 7.57 7.57
0.52 to 10.49 0.52 to 10.49 10.49 10.49 1.67 to 35.76 1.67 to 35.76 35.76 35.76 4.24 to 84.10 4.24 to 84.10 84.10 84.10 6.32 to 126.18 126.18
Adjustable 85MHP17* 85M2 Fixed Output 85MPHP17* 85MP2 Adjustable 85MHP40* 85M3 Fixed Output 85MPHP40* 85MP3 Adjustable 85M4 Fixed Output 85MP4 Adjustable 85M5 Fixed Output 85MP5
*pump supplied with injection check valve for 26-100 psi applications
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
Approx. Outputs @ 60 Hz
Double Head Model Adjustable 100DMHP5* 100DM1 Fixed Output 100DMPHP5* 100DMP1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute
Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute
100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar
#1 #1 #1 #1 #2 #2 #2 #2 #3 #3 #4 #4 #5 #5
0.3 to to 6.0 6.0 0.3 6.0 6.0 1.0 to 20.0 1.0 to 20.0 20.0 20.0 2.2 to 44.0 44.0 3.5 to 70.0 70.0 5.0 to 100.0 100.0
1.1 to to 22.7 22.7 1.1 22.7 22.7 3.8 to 75.7 3.8 to 75.7 75.7 75.7 8.3 to 166.5 166.5 13.2 to 265.0 265.0 18.9 to 378.5 378.5
0.01 to to 0.25 0.25 0.01 0.25 0.25 0.04 to 0.83 0.04 to 0.83 0.83 0.83 0.09 to 1.83 1.83
0.05 0.03 to to 0.53 0.53 0.05 to to 0.95 0.95 0.03 0.95 0.95 0.16 to 3.15 0.16 to 3.15 3.15 3.15 0.35 to 6.94 6.94 0.53 0.53 0.09 to 1.78 0.09 to 1.78 1.78 1.78 0.19 to 3.91 3.91
0.76 to to 15.76 15.76 0.76 15.76 15.76 2.64 to 52.57 2.64 to 52.57 52.57 52.57 5.76 to 115.63 115.63 9.17 to 184.03 184.03 13.13 to 262.88 262.88
0.9 to to 18.2 18.2 0.9 18.2 18.2 3.0 to 60.6 3.0 to 60.6 60.6 60.6 6.6 to 133.2 133.2 10.6 to 212.0 212.0
0.04 to to 0.76 0.76 0.04 0.76 0.76 0.13 to 2.53 0.13 to 2.53 2.53 2.53 0.28 to 5.55 5.55 0.44 to 8.83 8.83
0.61 to to 12.64 12.64 0.61 12.64 12.64 2.11 to 42.06 2.11 to 42.06 42.06 42.06 4.58 to 92.50 92.50 7.36 to 147.22 147.22
Adjustable 100DMHP20* 100DM2 Fixed Output 100DMPHP20* 100DMP2 Adjustable 100DM3 Fixed Output 100DMP3 Adjustable 100DM4 Fixed Output 100DMP4 Adjustable 100DM5 Fixed Output 100DMP5
*pump supplied with injection check valve for 26-100 psi applications
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
10
www.stenner.com
Approx. Outputs @ 60 Hz
Double Head Model Adjustable 170DMHP9* 170DM1 Fixed Output 170DMPHP9* 170DMP1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute
Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute
100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar
#1 #1 #1 #1 #2 #2 #2 #2 #3 #3 #4 #4 #5 #5
0.5 to 10.0 0.5 to 10.0 10.0 10.0 1.7 to 34.0 1.7 to 34.0 34.0 34.0 4.0 to 80.0 80.0 6.0 to 120.0 120.0 8.5 to 170.0 170.0
1.9 to 37.9 1.9 to 37.9 37.9 37.9 6.4 to 128.7 6.4 to 128.7 128.7 128.7 15.1 to 302.8 302.8 22.7 to 454.2 454.2 32.2 to 643.5 643.6
0.02 to 0.42 0.02 to 0.42 0.42 0.42 0.07 to 1.42 0.07 to 1.42 1.42 1.42
0.08 to 1.58 0.08 to 1.58 1.58 1.58 0.27 to 5.36 0.27 to 5.36 5.36 5.36
0.04 to 0.89 0.04 to 0.89 0.89 0.89 0.15 to 3.02 0.15 to 3.02 3.02 3.02
1.32 to 26.32 1.32 to 26.32 26.32 26.32 4.44 to 89.38 4.44 to 89.38 89.38 89.38 10.49 to 210.28 210.28
1.5 to 30.3 1.5 to 30.3 30.3 30.3 5.1 to 103.0 5.1 to 103.0 103.0 103.0
0.06 to 1.26 0.06 to 1.26 1.26 1.26 0.21 to 4.29 0.21 to 4.29 4.29 4.29
1.04 to 21.04 1.04 to 21.04 21.04 21.04 3.54 to 71.55 3.54 to 71.55 71.55 71.55 8.40 to 168.22 168.22
Adjustable 170DMHP34* 170DM2 Fixed Output 170DMPHP34* 170DMP2 Adjustable 170DM3 Fixed Output 170DMP3 Adjustable 170DM4 Fixed Output 170DMP4 Adjustable 170DM5 Fixed Output 170DMP5
0.25 to 5.00 0.95 to 18.93 0.53 to 10.66 15.76 to 315.42 5.00 0.35 to 7.08 7.08 18.93 10.66 315.42
*pump supplied with injection check valve for 26-100 psi applications
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
11
12
www.stenner.com
Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute
#1 #1 #2 #2 #3 #4 #5
0.2 to 3.0 0.2 to 3.0 0.5 to 10.0 0.5 to 10.0 1.1 to 22.0 1.7 to 35.0 2.5 to 50.0
0.8 to 11.4 0.8 to 11.4 1.9 to 37.9 1.9 to 37.9 4.2 to 83.3 6.4 to 132.5 9.5 to 189.3
0.01 to 0.13 0.01 to 0.13 0.02 to 0.42 0.02 to 0.42 0.05 to 0.92 0.07 to 1.46 0.10 to 2.08
0.03 to 0.48 0.03 to 0.48 0.08 to 1.58 0.08 to 1.58 0.18 to 3.47 0.27 to 5.52 0.40 to 7.89
0.02 to 0.27 0.02 to 0.27 0.04 to 0.89 0.04 to 0.89 0.10 to 1.96 0.15 to 3.11 0.22 to 4.44
0.56 to 7.92 0.56 to 7.92 1.32 to 26.32 1.32 to 26.32 2.92 to 57.85 4.44 to 92.01 6.60 to 131.46
0.6 to 9.1 0.6 to 9.1 1.5 to 30.3 1.5 to 30.3 3.3 to 66.6 5.1 to 106.0 7.6 to 151.4
0.03 to 0.38 0.03 to 0.38 0.06 to 1.26 0.06 to 1.26 0.14 to 2.78 0.21 to 4.42 0.32 to 6.31
0.42 to 6.32 0.42 to 6.32 1.04 to 21.04 1.04 to 21.04 2.29 to 46.25 3.54 to 73.61 5.28 to 105.14
100MDCHP20* 100 psi/6.9 bar 100MDC2 25 psi/1.7 bar 100MDC3 100MDC4 100MDC5 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar
*pump supplied with injection check valve for 26-100 psi applications
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
13
14
www.stenner.com
Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute
#1 #1 #2 #2 #3 #4 #5
0.3 to 5.0 0.3 to 5.0 0.8 to 17.0 0.8 to 17.0 2.0 to 40.0 3.0 to 60.0 4.3 to 85.0
1.1 to 18.9 1.1 to 18.9 3.0 to 64.4 3.0 to 64.4 7.6 to 151.4 11.4 to 227.1 16.3 to 321.8
0.01 to 0.21 0.01 to 0.21 0.03 to 0.71 0.03 to 0.71 0.08 to 1.67 0.13 to 2.5 0.18 to 3.54
0.05 to 0.79 0.05 to 0.79 0.13 to 2.68 0.13 to 2.68 0.32 to 6.31 0.48 to 9.46 0.68 to 13.40
0.03 to 0.44 0.03 to 0.44 0.07 to 1.51 0.07 to 1.51 0.18 to 3.55 0.27 to 5.33 0.38 to 7.55
0.76 to 13.13 0.76 to 13.13 2.08 to 44.65 2.08 to 44.65 5.27 to 105.14 7.92 to 157.71 11.32 to 223.40
0.9 to 15.1 0.9 to 15.1 2.4 to 51.5 2.4 to 51.5 6.1 to 121.1 9.1 to 181.7
0.4 to 0.63 0.4 to 0.63 0.10 to 2.15 0.10 to 2.15 0.25 to 5.05 0.38 to 7.57
0.63 to 10.49 0.63 to 10.49 1.67 to 35.76 1.67 to 35.76 4.24 to 84.10 6.32 to 126.18
170MDCHP34* 100 psi/6.9 bar 170MDC2 25 psi/1.7 bar 170MDC3 170MDC4 170MDC5 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar
*pump supplied with injection check valve for 26-100 psi applications
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
15
Materials of Construction
All Housings* . . . . . . . . . . . . . . . . . Lexan Polycarbonate Plastic Peristaltic Tube** . . . . . . . . . . . . . . Santoprene FDA Approved Check Valve Duckbill Peristaltic Tube . . . . . . . . . . . . . . . Tygothane FDA Approved Check Valve Duckbill . . . . . . . . . . Pellathane Suction/Discharge Tubing . . . . . . . . LDPE Polyethylene-NSF/FDA Approved Ferrules (1/4" & 6mm) Tube Fittings . . . . . . . . . . . . . . . . . Type 1 Rigid PVC-NSF Listed Connecting Nuts Check Valve Fittings Weighted Suction Line Strainer All Fasteners . . . . . . . . . . . . . . . . . Stainless Steel
*Lexan is a registered trademark of General Electric. Consult General Electric for chemical resistance of Lexan. **Santoprene is a registered trademark of Advanced Elastomer System, Akron, OH.
Tygothane is a registered trademark of Saint-Gobain Performance Plastics, Pittsburgh, PA. Pellathane is a registered trademark of The Dow Company, Midland, MI.
16
www.stenner.com
17
18
www.stenner.com
Installation
continued
mount pump
MOUNT PUMP
1. Use the mounting bracket as a template to drill pilot holes in mounting location. 2. Secure bracket with fasteners or wall anchors. Slide pump into bracket.
Provide 8" clearance to allow pump orientation to be reversed during tube replacement. Do not allow water intrusion into the motor or corrosion and damage will occur. To prevent motor damage, verify with a volt meter that the receptacle voltage corresponds with the pump voltage.
Rain roof (optional) slips onto wall bracket
Select a dry location (to avoid water intrusion and pump damage) above the solution tank. Best recommended location is above the solution tank in a vertical position with the pump head pointed downward and the spill recovery (see next page) in place to reduce the risk and severity of damage. To prevent pump damage in the event of a pump tube leak, never mount the pump vertically with the pump head up. To avoid chemical damage from fumes, do not mount pump directly over an open solution tank. Keep tank covered. Avoid flooded suction or pump mounted lower than the solution container. Draw solution from the top of the tank. If pump is installed with a flooded suction, a shut-off valve or other device must be provided to stop flow to pump during service.
Wall bracket
3. Plug cord into receptacle and turn the motor power switch on. If the pump is adjustable, turn the dial ring to 10. 4. Activate the pump by the pump control (flow switch, pressure switch, etc.) and verify rotation of the roller assembly within the clear pump head. Turn pump switch off.
Pump head
19
Installation
Additional Installation Instructions 1. All Class II Pumps located
in Zone 1 of swimming pool areas require locating where flooding cannot occur.
continued
3. Es necesario instalar el
techo de lluvia, y montar la unidad entera siguiendo una orintacin vertical.
4. Aprs linstallation, la
prise lectrique doit rester accessible pendant lutilisation.
4. Depus de la instalacin
el enchufe suministrador de energia debe estar accesible durante el uso.
4. Dopo linstallazione, la
spina deve essere accessibile durante luso.
5. Se deber desechar la
unidad si el cordn de abastecimiento se deteriora.
5. Bei beschadigter
Verkabelung ist dieses Gerat nicht mehr zu gebrauchen.
6. Observez et adhrez
toutes les Normes Nationales pour Installations Electriques.
6. Osservare e aderire a
tutte le Norme Nazionali Sugli Impianti Elettrici.
6. Staatliche
Vernetzungsvorchriften mussen eingehalten werden.
20
www.stenner.com
Installation Diagram
Rain roof slips onto slots in the wall mounting bracket. (No tools necessary) On/Off Switch (Under roof not visible this view)
Always use rain roof for outdoor use or if metering pump is subject to washdowns.
Wall Mounting Bracket (Requires 2 screws) IN (Suction) Shut-Off Valve OUT (Discharge)
Disassembled View
Injection Tube
Solution Tank
21
Installation
continued
spill recovery
SPILL RECOVERY
In case of tube rupture, chemical drains back into solution tank, preventing spillage onto ground/floor and stops chemical from collecting in tube housing.
Spill Recovery Tube Spill recovery tube drains solution back to tank.
Partial hole is punched through with a #2 Phillips head screwdriver. 1/4" plastic spill recovery tube is inserted in hole. Use section of suction/discharge tubing.
Strainer w/weight
22
www.stenner.com
Installation
continued
suction line
3. Finger tighten nut to the threaded tube fitting while holding the tube fitting.
Over tightening the ferrule and nut with a wrench may result in damaged fittings, crushed ferrules, and air pickup. Do not use thread sealant tape on pump tube connections or tools to tighten connections.
DO NOT use Teflon tape on pump tube threads. DO NOT use pliers.
2. Slide the suction line through the connecting nut and ferrule and fully insert the line into the bottom pump tube fitting as indicated by the IN on the tube housing cover.
OUT
Note: Beveled ends of ferrules face pump. Tubing should bottom into all fittings.
IN
23
Installation
continued
suction line
4. Drill a 17/64" hole into the lid or bung cap of the solution tank. Secure strainer weight to the end of the suction line as per provided instructions and feed it into the hole. Suspend 2-3" above the tank bottom.
5.
Strainer w/weight
Do not mix chemicals in the solution container. Follow recommended mixing procedures according to the manufacturer.
Do not operate pump unless chemical is completely in solution. Turn pump off when replenishing solution.
24
www.stenner.com
Installation
continued
discharge line
Locate a point of injection beyond all pumps and filters or as determined by the application.
DO NOT use Teflon tape on pump tube threads. DO NOT use pliers.
2. A 1/4" or 1/2" female NPT connection is required for the injection fitting. If there is no FNPT fitting available, provide one by either tapping the pipe or installing FNPT pipe tee fitting. 3. Wrap MNPT end of injection fitting with 2 to 3 turns of threading tape. If necessary trim straight-sided extension tip so it is in the flow of water. See Illustration 4. Tighten the injection fitting into the FNPT fitting.
HAZARDOUS PRESSURE:
Shut off water or circulation system and bleed off any system pressure.
25
Installation
continued
discharge line
The injection point and fitting require periodic maintenance to clean any deposits or buildup. To allow quick access to the point of injection, Stenner recommends the installation of shut-off valves.
26-100 psi models: Prior to making tubing connection, test check valve and NPT threads for leaks by pressurizing system. Tighten an additional 1/4 turn if necessary. Make final tube connection as instructed in Install Suction Line instructions.
0-25 psi models: Low-pressure models do not have a check valve and check valve body. Insert the tubing 3/4" to 1" into the injection fitting and make tubing connection as instructed in Install Suction Line instructions. 5. Turn pump switch on and observe chemical flow as actuated by system. 6. After a suitable amount of dosing time, perform tests for required chemical levels. If necessary, fine-tune dosing levels by rotating dial ring (adjustable pumps only).
HAZARDOUS PRESSURE:
Shut off water or circulation system and bleed off any system pressure.
26
www.stenner.com
Troubleshooting motor
PROBLEM
Motor
POSSIBLE CAUSE
HAZARDOUS VOLTAGE:
SOLUTION
DISCONNECT power cord before removing motor cover for service. Electrical service should be by trained personnel only. Noise is excessively loud. Ball bearings are worn. Lubrication is insufficient. Gears or gear posts are worn. Motor does not work; fan is not turning. Electrical supply is faulty. Rotor bound to coil. Motor coil is damaged. Motor bearings are worn or damaged. Power cord is damaged. Rotor rusted to coil. Wire connections are faulty. Fan is obstructed. Motor runs; fan turns; output shaft does not. Motor overheats and shuts off and on. Check all gears. Voltage is incorrect. Ambient temperature is high. Coil is damaged/malfunctioning. Phenolic gear is stripping. Water intrusion. Cracked bearing bracket. Gear posts worn. Rusted helical gear at end of rotor. Worn gear case cover. Insufficient lubrication. Replace rotor assembly. Grease gears and gear posts. Inspect/replace gears and gear posts. Check supply voltage circuit. Check bearing brackets for cracks and replace if necessary. Replace motor coil. Replace rotor assembly. Inspect/replace power cord. Clean off coil and rotor or replace as needed. Inspect/repair electrical connections. Remove obstruction. Replace gears as needed. Check that voltage and frequency match data label. Install pump in an area not to exceed a maximum of 125 F. Replace motor coil. Use rain roof. Replace bearing bracket. Replace gear posts. Buff off rotor or replace rotor. Replace gear case cover. Lubricate with AquaShield.
27
Troubleshooting
PROBLEM
Feed Rate Control
Adjustment ring will not turn.
continued
POSSIBLE CAUSE
Variable cam has seized. Adjustment ring has seized.
Index plate is worn. Problem with the gear motor. Pump head roller assembly is stripped. Index pin holder backed out of spider assembly. Index pin is broken.
Variable cam is installed incorrectly. Index plate is worn. Variable cam is worn. Lifter is worn.
28
www.stenner.com
Troubleshooting
PROBLEM
Pump Head
Components are cracking. Visible fluid in pump head. No pump output; pump head rotates.
continued
pump head
SOLUTION
Check chemical compatibility. Replace pump tube and ferrules and center tube. Replenish solution. Maintain suction line 2-3" off bottom of tank. Inspect or replace suction line. Replace compression ferrules. Inspect and clean injection point. Clean and/or replace as necessary. Replace pump tube. Replace pump tube. Install new rollers or roller assembly. Inspect and clean injection point. Check tube psi rating against system pressure; replace accordingly. Replace roller assembly. Refer to Feed Rate Control section. Refer to Motor section. Replace tube with correct size. Replace roller assembly. Refer to Feed Rate Control section. Replace with proper motor.
POSSIBLE CAUSE
Chemical attack. Pump tube rupture/leak. Depleted solution tank. Pump suction line weight is above solution. Suction line leak. Ferrules installed incorrectly or damaged. Injection point is clogged. Clogged suction/discharge tubing and/or injection check valve. Life of pump tube is exhausted.
Pump tube is worn. Rollers missing or cracked. Injection point is restricted. High system back pressure.
Incorrect tube size. Roller assembly is broken. Malfunctioning Feed Rate Control. Incorrect model of motor.
29
Troubleshooting
PROBLEM
Pump Tube
Tube is leaking.
continued
pump tube
SOLUTION
POSSIBLE CAUSE
NOTICE: A leaking pump tube damages the metering pump. Inspect pump frequently for leakage
and wear. Refer to Tube Replacement section for additional safety precautions and instructions. Pump tube has ruptured. Calcium or mineral deposit. Excessive back pressure. Tube is twisted. Tube is not centered. Replace pump tube at routine intervals. Clean injection fitting, replace pump tube. Check tube psi rating against system pressure; replace accordingly. Replace tube according to instructions. Replace tube and center it. Check chemical compatibility. Remove deposit and replace pump tube. Maintain suction line 2-3" above bottom of tank. Use a suction line strainer. Replace check valve duckbill at every tube change. Reverse duckbill orientation. See tube replacement instructions. Allow roller assembly to stretch tube into place. Clean roller assembly or replace.
Chemical attack. Mineral deposit at injection point. Sediment blockage at check valve. Degraded check valve duckbill. Duckbill in wrong orientation. Tube was manually stretched to lock into discharge side slot. Seized rollers caused abrasion on tube.
30
www.stenner.com
NOTICE: DO NOT apply grease, oil, or lubricants to the pump tube or housing. NOTICE: Prior to pump tube replacement, inspect the entire
pump head for cracks or damaged components. Ensure rollers turn freely.
NOTICE: Rinse off chemical residual and clean all chemical and debris from pump head components prior to tube replacement. Apply Stenner grease to main shaft and tube housing cover bushing during tube replacement. NOTICE: DO NOT pull excessively on pump tube. Avoid
kinks or damage during tube installation.
Tube Replacement
continued
preparation
4. Disconnect the suction and discharge connections from pump head. 5. Plug power cord into constantly energized, properly grounded receptacle for service.
1. Follow all safety precautions prior to tube replacement. 2. Prior to service, pump water or a compatible buffer solution through the pump and suction/discharge line to remove chemical and avoid contact. 3. Turn pump off.
32
www.stenner.com
Tube Replacement
1. Remove and set aside cover and screws. 2. Set feed rate dial on the low setting until finished. 3. Turn pump on and let it run until one of three roller assembly slots lines up with the tube fitting on the suction side. Illustration A 4. Turn pump off. 5. Lift tube fitting out of housing slot and pull it toward center of roller assembly. Illustration B 6. Turn pump on and allow roller assembly to jog while guiding tube, with tension, up and out of housing. Illustration C 7. Turn pump off. Remove and discard pump tube.
continued
Pull Out
Pull Out
Check Rollers
33
Tube Replacement
IMPORTANT! Do not lubricate pump tube or roller assembly.
continued
1. By manually rotating the roller assembly counter clockwise, align one of three roller assembly slots with the suction side housing slot.
Tube Housing Slot Roller Assembly Slot
2. Place tube fitting into suction side slot of the housing and the roller assembly slot. Illustration E 3. With pump setting on low, hold tube fitting and jog roller assembly by turning pump on.
Guide
G
Guide
IMPORTANT! Avoid rotating wrist, which can result in a twisted tube that will not center. Do not force tube and be careful of your fingers. 4. Guide tube, with slight tension (toward the center) to prevent pinching between housing and roller assembly. Illustration F
NOTE: Cover screws are self-tapping and must be backed in to locate original thread before securing. If a screw boss is stripped, use alternate bosses and position opposite from each other. Never secure the cover plate with more than 2 screws.
34
www.stenner.com
Tube Replacement
1. To center pump tube on rollers, set feed rate dial to setting 10. Turn pump on. Illustration H 2. Turn the tube fitting on the suction side not more than 1/8 of a turn in the direction tube must move.
continued
35
Power Cord Rotor Assembly with Bearings, Brackets, Tolerance Rings & Fan Gear Case Gear Post Phenolic Gear Phenolic Gear Spacer
Rain Roof
Coil
Pressure Spring
(adjustable models only)
Toggle Switch
36
www.stenner.com
Motor
MOTORS
DESCRIPTION
continued
subassemblies
PART NUMBER
(120v) PM6041D (120v) PM6081D (120v) ME6041D (120v) ME6081D (120v) DM6041D (120v) DM6081D
UM
EA EA EA EA EA EA
PART NUMBER
(220v) PM6042D (220v) PM6082D (220v) ME6042D (220v) ME6082D (220v) DM6042D (220v) DM6082D
UM
EA EA EA EA EA EA
Motor 60Hz (adjustable output 45 & 100 series) Motor 60Hz (adjustable output 85 & 170 series) Motor 60Hz (fixed output 45MP series only) Motor 60Hz (fixed output 85MP series only) Motor 60Hz (fixed output 100DMP series only) Motor 60Hz (fixed output 170DMP series only)
EUROPE
Motor 50Hz (adjustable output 45 & 100 series) Motor 50Hz (adjustable output 85 & 170 series) Motor 50Hz (fixed output 45MP series only) Motor 50Hz (fixed output 85MP series only) Motor 50Hz ((fixed output 100DMP series only) Motor 50Hz (fixed output 170DMP series only) (230v) PM64230 (230v) PM68230 (230v) ME64230 (230v) ME68230 (230v) DM64230 (230v) DM68230 EA EA EA EA EA EA (250v) PM6426D (250v) PM6826D (250v) ME6426D (250v) ME6826D (250v) DM64250 (250v) DM68250 EA EA EA EA EA EA Motor
37
Motor
continued
service kits
MOTOR SERVICE KITS
DESCRIPTION
Motor Service Kit 60Hz
PART NUMBER
(120v) MSK120
UM
Kit
PART NUMBER
(220v) MSK220
UM
Kit
DESCRIPTION
Gear Case Service Kit (adjustable output 45 & 100) Gear Case Service Kit (adjustable output 85 & 170) Gear Case Service Kit (fixed output 45MP series only) Gear Case Service Kit (fixed output 85MP series only)
PART NUMBER
GSK45A GSK85A GSK45F GSK85F
UM
Kit Kit Kit Kit
38
www.stenner.com
Roller Clutch
Main Shaft Double Head/Adjustable Output Main Shaft Dual Head Dual Control/Adjustable Output
39
continued
UM
EA EA EA
PART NUMBER
FSK100
UM
Kit
Lifter
Variable Cam
40
www.stenner.com
Roller
41
Pump Head
Pump Head
continued
subassemblies
PUMP HEADS
DESCRIPTION
Pump Head includes SANTOPRENE pump tube; ferrules 1/4" Pump Head includes SANTOPRENE pump tube & duckbill; ferrules 1/4" Pump Head includes TYGOTHANE pump tube; ferrules 1/4" Pump head includes TYGOTHANE #2 pump tube; PELLATHANE duckbill; ferrules 1/4"
PART NUMBER
UM
PART NUMBER UM
PK of 2 n/a n/a n/a
UCTHC * D EA MCTHC * D * select tube number 1, 2, 3, 4, 5, 7 UCPH * FD EA n/a * select tube number 1, 2, 7 UCPHT0 * EA * select tube number 2, 5 UCPHTD2 EA n/a n/a
EUROPE Pump Tube Numbers #1 and #2 for 26-100 psi pump (when used with check valve). #1, 2, 3, 4, 5 for 0-25 psi pump. #7 tube for 26-100 psi single head pump only.
Pump Head includes SANTOPRENE pump tube; ferrules 6mm Pump Head includes SANTOPRENE pump tube & duckbill; ferrules 6mm Pump Head includes TYGOTHANE pump tube; ferrules 6mm Pump head includes TYGOTHANE #2 pump tube; PELLATHANE duckbill; ferrules 6mm UCTH * CE EA MCTH * CE * select tube number 1, 2, 3, 4, 5, 7 UCPH * CE EA n/a * select tube number 1, 2, 7 UCPHT * CE EA * select tube number 2, 5 UCPHD2CE EA n/a n/a PK of 2 n/a n/a n/a
42
www.stenner.com
Pump Head
DESCRIPTION
continued
service kits
UM
PSKL0_*_ KIT * select tube number 1, 2, 3, 4, 5 PSKH0_*_ KIT * select tube number 1, 2, 7 PSKLT * KIT * select tube number 2 or 5 PSKHT2 KIT
Pump Tube
EUROPE
SANTOPRENE Kit (1.7 bar) SANTOPRENE Kit (1.7-6.9 bar) TYGOTHANE Kit (1.7 bar) KIT: TYGOTHANE #2 Pump Tube & PELLATHANE duckbill included
PSKL * CE KIT * select tube number 1, 2, 3, 4, 5 PSKH * CE KIT * select tube number 1, 2, 7 PSKLT * CE KIT * select tube number 2 or 5 PSKHT2CE KIT
Pump Tube
43
PART NUMBER
UM
PART NUMBER UM
PK of 2 n/a n/a n/a
UC1ATC * EA MC1ATC * * select tube number 1, 2, 3, 4, 5 UCAH * FD EA n/a * select tube number 1, 2 UCAHT0 * EA n/a * select tube number 2, 5 UCAHTD2 EA n/a
EUROPE
Adapter Pump Head includes SANTOPRENE pump tube; ferrules 6mm Adapter Pump Head includes SANTOPRENE pump tube & duckbill; ferrules 6mm Adapter Pump Head includes TYGOTHANE pump tube; ferrules 6mm Adapter Pump Head includes #2 TYGOTHANE pump tube; PELLATHANE duckbill; ferrules 6mm UCAP * CE EA MCAP * CE * select tube number 1, 2, 3, 4, 5 UCAH * CE EA n/a * select tube number 1, 2 UCAT * CE EA n/a * select tube number 2, 5 UCT2DCE EA n/a PK of 2 n/a n/a n/a
44
www.stenner.com
Pump Tubes
PUMP TUBES
DESCRIPTION
SANTOPRENE Pump Tube ferrules 1/4" SANTOPRENE Pump Tube & duckbill; ferrules 1/4" TYGOTHANE Pump Tube; ferrules 1/4" TYGOTHANE #2 Pump Tube & PELLATHANE duckbill; ferrules 1/4"
PART NUMBER
UM
PART NUMBER UM
PK of 5 n/a PK of 5 n/a
UCCP20 * PK of 2 MCCP20 * * select tube number 1, 2, 3, 4, 5, 7 UCCP * FD PK of 2 n/a * select tube number 1, 2, 7 UCTYG0 * PK of 2 MCTYG0 * * select tube number 2, 5 UCTY2FD PK of 2 n/a
EUROPE
SANTOPRENE Pump Tube ferrules 6mm SANTOPRENE Pump Tube & duckbill; ferrules 6mm TYGOTHANE Pump Tube ferrules 6mm TYGOTHANE #2 Pump Tube & PELLATHANE duckbill; ferrules 6mm UCCP2 * CE PK of 2 MCCP2 * CE * select tube number 1, 2, 3, 4, 5, 7 UC * FDCE PK of 2 n/a * select tube number 1, 2, 7 UCTY * CE PK of 2 MCTY * CE * select tube number 2, 5 UCTY2DCE PK of 2 n/a PK of 5 n/a PK of 5 n/a
Pump Tube Numbers #1 and #2 for 26-100 psi pump (when used with check valve). #1, 2, 3, 4, 5 for 0-25 psi pump. #7 tube for 26-100 psi single head pump only.
45
Check Valves
CHECK VALVES
DESCRIPTION
Injection Check Valve 1/4" Check Valve includes SANTOPRENE duckbill; ferrules 1/4"
PART NUMBER
UCDBINJ UCTYINJ
UM
EA EA
PART NUMBER UM
MCDBINJ MCTYINJ PK of 5 PK of 5
Check Valve includes SANTOPRENE duckbill; ferrules 3/8" Check Valve includes PELLATHANE duckbill; ferrules 3/8"
UCINJ38 UCTYIJ38
EA EA
MCINJ38 MCTYIJ38
PK of 5 PK of 5
EUROPE Injection Check Valve 6mm Check Valve includes SANTOPRENE duckbill; ferrules 6mm Check Valve includes PELLATHANE duckbill; ferrules 6mm UCINJCE UCTINJCE EA EA MCINJCE MCTINJCE PK of 5 PK of 5
46
www.stenner.com
47
3174 DeSalvo Road Jacksonville, Florida 32246 [email protected] www.stenner.com Phone: 904.641.1666 US Toll Free: 800.683.2378 Fax: 904.642.1012
Hours of Operation (EST): Mon. Thu. 7am 5pm Friday 7am Noon