Stenner Classic Series Installation Instructions

Download as pdf or txt
Download as pdf or txt
You are on page 1of 48

Classic Series

I N S TA L L AT I O N M A N U A L
Metering Pumps Manufactured Since 1957

Table of Contents
Warranty and Service Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Pump Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15 Materials of Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Accessory Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-26 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27-30 Tube Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-35 Motor exploded view and parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-38 Feed Rate Control exploded view and parts . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40 Pump Head exploded view and parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41-44 Pump Tubes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 For Your Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
CIMM06
2 www.stenner.com

Warranty and Service Policy


Damaged or Lost Shipments UPS and prepaid truck shipments: Check your order immediately upon arrival. All damage must be noted on the delivery receipt. Call Stenner Customer Service at 800.683.2378 for all shortages and damages within seven (7) days of receipt. Returns Stenner offers a 30-day return policy on factory direct purchases. Except as otherwise provided, no material will be accepted for return after 30 days from purchase. To return merchandise at any time, call Stenner at 800.683.2378 for a Returned Goods Authorization (RGA) number. A 15% re-stocking fee will be applied. Include a copy of your invoice or packing slip with your return. Limited Warranty Stenner Pump Company will for a period of one (1) year from the date of purchase (proof of purchase required) repair or replace at our option all defective parts. Stenner Pump Company is not responsible for any removal or installation costs. Pump tube assemblies and rubber components are considered perishable and are not covered in this warranty. Pump tube will be replaced each time a pump is in for service, unless otherwise specified. The cost of the pump tube replacement will be the responsibility of the customer. Stenner Pump Company will incur shipping costs for warranty products shipped from our factory in Jacksonville, Florida. Any tampering with major components, chemical damage, faulty wiring, weather conditions, water damage, power surges, or products not used with reasonable care and maintained in accordance with the instructions will void the warranty. Stenner Pump Company limits its liability solely to the cost of the original product. We make no other warranty expressed or implied. Disclaimer The information contained in this manual is not intended for specific application purposes. Stenner Pump Company reserves the right to make changes to prices, products, and specifications at any time without prior notice.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

Safety Information
Warns about hazards that CAN cause death, serious personal injury, or property damage if ignored.

ELECTRIC SHOCK HAZARD

ELECTRIC SHOCK HAZARD:


Pump supplied with grounding power cord and attached plug. To reduce risk of electrical shock, connect only to a properly grounded, grounding type receptacle.

HAZARDOUS VOLTAGE: DISCONNECT power cord before removing motor cover for
service. Electrical service by trained personnel only.

EXPLOSION HAZARD:
This pump is not explosion proof. Do Not install or operate in an explosive environment.

AVERTISSEMENT RISQUE DE CHOC ELECTRIQUE:


Cette pompe est quipe dune fiche de mise terre. Pour rduire le risque de choc lectrique, sassurer que la fiche est bien raccorde une prise de courant avec une connexion de mise terre. DO NOT alter the power cord or plug end. DO NOT use receptacle adapters. DO NOT use pump with a damaged or altered power cord or plug. Contact the factory or an authorized service facility for repair.

RISK OF CHEMICAL EXPOSURE:


Potential for chemical burns, fire, explosion, personal injury, or property damage. To reduce risk of exposure, the use of proper personal protective equipment is mandatory.

RISK OF FIRE HAZARD:


Do Not install or operate on any flammable surface.

RISK OF CHEMICAL OVERDOSE:


To reduce risk, follow proper installation methods and recommendations. Check your local codes for additional guidelines.

www.stenner.com

Safety Information
PLUMBING:

continued
This is the safety alert symbol. When displayed in this manual or on the equipment, look for one of the following signal words alerting you to the potential for personal injury or property damage.

Warns about hazards that WILL or CAN cause minor personal injury or property damage if ignored.

Chemical feed pump installation must always adhere to your local plumbing codes and requirements. Be sure installation does not constitute a cross connection. Check local plumbing codes for guidelines.

PUMP SUITABLE FOR USE OUTDOORS when installed with a Stenner Rain Roof Part No. MP90000. Electrical installation should adhere to all national and local codes. Consult a licensed professional for assistance with proper electrical installation. Removing power from pool/spa recirculation pump must also remove power from pump. The use of an auxiliary safety device (not supplied), such as a flow switch or sensor, is recommended to prevent feed pump operation in the event of a recirculation pump failure or if flow is not sensed. Point of chemical injection should be beyond all pumps, filters, and heaters. PUMP INTENDED FOR INDOOR USE. Cette pompe est prvue pour utilisation lintrieur.

NOTICE: Indicates special instructions or general


mandatory action.

NOTICE: This metering pump is portable and designed


to be removable from the plumbing system without damage to the connections.

NOTICE: This metering pump and its components


have been tested for use with the following chemicals: Sodium Hypochlorite (10-15%), Muriatic Acid (20-22% Baume, 31.5% Hcl), and Soda Ash.

NOTE: Cette a pompe de dosage et ses composants ont


t tests pour utilisation avec les produits chimiques suivants; Hypochlorite de Sodium (solution de 10-15%); Acide Muriatique (20-22% Baume, 31.5% Hcl); Cendre de Soude.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

Pump Identification
Identify your pump using the label on the box or the pump.

Box Label

85MHP5 02010503943 120 5/18.9 Adjustable 5/18.9 Ajustable 5/18.9 100/6.9 1/4" White 1/4" Blanco 85MJH1A1STAA

Model Serial Number Voltage Maximum Output per Day Maximum Operating Pressure Suction/Discharge Tubing Item Number for Placing Order

www.stenner.com

Pump Identification

continued

Pump Label
STENNER PUMP COMPANY

Agency Listings (varies by model)

Model Maximum Operating Pressure Amp Draw

85MHP5 100 psi / 6.9 bar 1.7 amp

85MJH1A1STAA 120VAC / 60Hz 5 GPD / 18.9 LPD 02010503943

Item Number for Placing Order Voltage Maximum Output per Day Serial Number

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

Outputs 45 series
The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. (20:1 Turndown Ratio)

Approx. Outputs @ 60 Hz
Single Head Model Adjustable 45MHP2* 45M1 Fixed Output 45MPHP2* 45MP1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute

Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute

100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar

#1 #1 #1 #1 #2 #2 #2 #2 #7 #3 #7 #3 #4 #4 #5 #5

0.2 to 3.0 0.2 to 3.0 3.0 3.0 0.5 to 10.0 0.5 to 10.0 10.0 10.0 1.1 to 22.0 1.1 to 22.0 22.0 22.0 1.7 to 35.0 35.0 2.5 to 50.0 50.0

0.8 to 11.4 0.8 to 11.4 11.4 11.4 1.9 to 37.9 1.9 to 37.9 37.9 37.9 4.2 to 83.3 4.2 to 83.3 83.3 83.3 6.4 to 132.5 132.5 9.5 to 189.3 189.3

0.01 to 0.13 0.01 to 0.13 0.13 0.13 0.02 to 0.42 0.02 to 0.42 0.42 0.42 0.05 to 0.92 0.05 to 0.92 0.92 0.92 0.07 to 1.46 1.46 0.10 to 2.08 2.08

0.03 to 0.48 0.03 to 0.48 0.48 0.48 0.08 to 1.58 0.08 to 1.58 1.58 1.58 0.18 to 3.47 0.18 to 3.47 3.47 3.47 0.27 to 5.52 5.52 0.40 to 7.89 7.89

0.02 to 0.27 0.02 to 0.27 0.27 0.27 0.04 to 0.89 0.04 to 0.89 0.89 0.89 0.10 to 1.96 0.10 to 1.96 1.96 1.96 0.15 to 3.11 3.11 0.22 to 4.44 4.44

0.56 to 7.92 0.56 to 7.92 7.92 7.92 1.32 to 26.32 1.32 to 26.32 26.32 26.32 2.92 to 57.85 2.92 to 57.85 57.85 57.85 4.44 to 92.01 92.01 6.60 to 131.46 131.43

0.6 to 9.1 0.6 to 9.1 9.1 9.1 1.5 to 30.3 1.5 to 30.3 30.3 30.3 3.3 to 66.6 3.3 to 66.6 66.6 66.6 5.1 to 106.0 106.0 7.6 to 151.4 151.4

0.03 to 0.38 0.03 to 0.38 0.38 0.38 0.06 to 1.26 0.06 to 1.26 1.26 1.26 0.14 to 2.78 0.14 to 2.78 2.78 2.78 0.21 to 4.42 4.42 0.32 to 6.31 6.31

0.31 to 6.32 0.31 to 6.32 6.32 6.32 1.04 to 21.04 1.04 to 21.04 21.04 21.04 2.29 to 46.25 2.29 to 46.25 46.25 46.25 3.54 to 73.61 73.61 5.28 to 105.14 105.14

Adjustable 45MHP10* 45M2 Fixed Output 45MPHP10* 45MP2 Adjustable 45MHP22* 45M3 Fixed Output 45MPHP22* 45MP3 Adjustable 45M4 Fixed Output 45MP4 Adjustable 45M5 Fixed Output 45MP5

*pump supplied with injection check valve for 26-100 psi applications

NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.

www.stenner.com

Outputs 85 series
The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. (20:1 Turndown Ratio)

Approx. Outputs @ 60 Hz
Single Head Model Adjustable 85MHP5* 85M1 Fixed Output 85MPHP5* 85MP1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute

Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute

100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar

#1 #1 #1 #1 #2 #2 #2 #2 #7 #3 #7 #3 #4 #4 #5 #5

0.3 to 5.0 0.3 to 5.0 5.0 5.0 0.8 to 17.0 0.8 to 17.0 17.0 17.0 2.0 to 40.0 2.0 to 40.0 40 40 3.0 to 60.0 60.0 4.3 to 85.0 85.0

1.1 to 18.9 1.1 to 18.9 18.9 18.9 3.0 to 64.4 3.0 to 64.4 64.4 64.4 7.6 to 151.4 7.6 to 151.4 151.4 151.4 11.4 to 227.1 227.1 16.3 to 321.8 321.8

0.01 to 0.21 0.01 to 0.21 0.21 0.21 0.03 to 0.71 0.03 to 0.71 0.71 0.71 0.08 to 1.67 0.08 to 1.67 1.67 1.67 0.13 to 2.5 2.50 0.18 to 3.54 3.54

0.05 to 0.79 0.05 to 0.79 0.79 0.79 0.13 to 2.68 0.13 to 2.68 2.68 2.68 0.32 to 6.31 0.32 to 6.31 6.31 6.31 0.48 to 9.46 9.46 0.68 to 13.40 13.40

0.03 to 0.44 0.03 to 0.44 0.44 0.44 0.07 to 1.51 0.07 to 1.51 1.51 1.51 0.18 to 3.55 0.18 to 3.55 3.55 3.55 0.27 to 5.33 5.33 0.38 to 7.55 7.55

0.76 to 13.13 0.76 to 13.13 13.13 13.13 2.08 to 44.65 2.08 to 44.65 44.65 44.65 5.27 to 105.14 5.27 to 105.14 105.14 105.14 7.92 to 157.71 157.71 11.32 to 223.40 223.40

0.9 to 15.1 0.9 to 15.1 15.1 15.1 2.4 to 51.5 2.4 to 51.5 51.5 51.5 6.1 to 121.1 6.1 to 121.1 121.1 121.1 9.1 to 181.7 181.7

0.4 to 0.63 0.4 to 0.63 0.63 0.63 0.10 to 2.15 0.10 to 2.15 2.15 2.15 0.25 to 5.05 0.25 to 5.05 5.05 5.05 0.38 to 7.57 7.57

0.52 to 10.49 0.52 to 10.49 10.49 10.49 1.67 to 35.76 1.67 to 35.76 35.76 35.76 4.24 to 84.10 4.24 to 84.10 84.10 84.10 6.32 to 126.18 126.18

Adjustable 85MHP17* 85M2 Fixed Output 85MPHP17* 85MP2 Adjustable 85MHP40* 85M3 Fixed Output 85MPHP40* 85MP3 Adjustable 85M4 Fixed Output 85MP4 Adjustable 85M5 Fixed Output 85MP5

13.0 to 257.4 0.54 to 10.73 9.03 to 178.75 257.4 10.73 178.75

*pump supplied with injection check valve for 26-100 psi applications

NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

Outputs 100 series


The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. (20:1 Turndown Ratio)

Approx. Outputs @ 60 Hz
Double Head Model Adjustable 100DMHP5* 100DM1 Fixed Output 100DMPHP5* 100DMP1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute

Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute

100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar

#1 #1 #1 #1 #2 #2 #2 #2 #3 #3 #4 #4 #5 #5

0.3 to to 6.0 6.0 0.3 6.0 6.0 1.0 to 20.0 1.0 to 20.0 20.0 20.0 2.2 to 44.0 44.0 3.5 to 70.0 70.0 5.0 to 100.0 100.0

1.1 to to 22.7 22.7 1.1 22.7 22.7 3.8 to 75.7 3.8 to 75.7 75.7 75.7 8.3 to 166.5 166.5 13.2 to 265.0 265.0 18.9 to 378.5 378.5

0.01 to to 0.25 0.25 0.01 0.25 0.25 0.04 to 0.83 0.04 to 0.83 0.83 0.83 0.09 to 1.83 1.83

0.05 0.03 to to 0.53 0.53 0.05 to to 0.95 0.95 0.03 0.95 0.95 0.16 to 3.15 0.16 to 3.15 3.15 3.15 0.35 to 6.94 6.94 0.53 0.53 0.09 to 1.78 0.09 to 1.78 1.78 1.78 0.19 to 3.91 3.91

0.76 to to 15.76 15.76 0.76 15.76 15.76 2.64 to 52.57 2.64 to 52.57 52.57 52.57 5.76 to 115.63 115.63 9.17 to 184.03 184.03 13.13 to 262.88 262.88

0.9 to to 18.2 18.2 0.9 18.2 18.2 3.0 to 60.6 3.0 to 60.6 60.6 60.6 6.6 to 133.2 133.2 10.6 to 212.0 212.0

0.04 to to 0.76 0.76 0.04 0.76 0.76 0.13 to 2.53 0.13 to 2.53 2.53 2.53 0.28 to 5.55 5.55 0.44 to 8.83 8.83

0.61 to to 12.64 12.64 0.61 12.64 12.64 2.11 to 42.06 2.11 to 42.06 42.06 42.06 4.58 to 92.50 92.50 7.36 to 147.22 147.22

Adjustable 100DMHP20* 100DM2 Fixed Output 100DMPHP20* 100DMP2 Adjustable 100DM3 Fixed Output 100DMP3 Adjustable 100DM4 Fixed Output 100DMP4 Adjustable 100DM5 Fixed Output 100DMP5

0.15 to 2.92 0.55 to 11.04 0.31 to 6.22 2.92 11.04 6.22

0.21 to 4.17 0.79 to 15.77 0.44 to 8.88 4.17 15.77 8.88

15.1 to 302.8 0.63 to 12.61 10.49 to 210.28 302.8 12.61 210.28

*pump supplied with injection check valve for 26-100 psi applications

NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.

10

www.stenner.com

Outputs 170 series


The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. (20:1 Turndown Ratio)

Approx. Outputs @ 60 Hz
Double Head Model Adjustable 170DMHP9* 170DM1 Fixed Output 170DMPHP9* 170DMP1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute

Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute

100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 100 psi/6.9 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar

#1 #1 #1 #1 #2 #2 #2 #2 #3 #3 #4 #4 #5 #5

0.5 to 10.0 0.5 to 10.0 10.0 10.0 1.7 to 34.0 1.7 to 34.0 34.0 34.0 4.0 to 80.0 80.0 6.0 to 120.0 120.0 8.5 to 170.0 170.0

1.9 to 37.9 1.9 to 37.9 37.9 37.9 6.4 to 128.7 6.4 to 128.7 128.7 128.7 15.1 to 302.8 302.8 22.7 to 454.2 454.2 32.2 to 643.5 643.6

0.02 to 0.42 0.02 to 0.42 0.42 0.42 0.07 to 1.42 0.07 to 1.42 1.42 1.42

0.08 to 1.58 0.08 to 1.58 1.58 1.58 0.27 to 5.36 0.27 to 5.36 5.36 5.36

0.04 to 0.89 0.04 to 0.89 0.89 0.89 0.15 to 3.02 0.15 to 3.02 3.02 3.02

1.32 to 26.32 1.32 to 26.32 26.32 26.32 4.44 to 89.38 4.44 to 89.38 89.38 89.38 10.49 to 210.28 210.28

1.5 to 30.3 1.5 to 30.3 30.3 30.3 5.1 to 103.0 5.1 to 103.0 103.0 103.0

0.06 to 1.26 0.06 to 1.26 1.26 1.26 0.21 to 4.29 0.21 to 4.29 4.29 4.29

1.04 to 21.04 1.04 to 21.04 21.04 21.04 3.54 to 71.55 3.54 to 71.55 71.55 71.55 8.40 to 168.22 168.22

Adjustable 170DMHP34* 170DM2 Fixed Output 170DMPHP34* 170DMP2 Adjustable 170DM3 Fixed Output 170DMP3 Adjustable 170DM4 Fixed Output 170DMP4 Adjustable 170DM5 Fixed Output 170DMP5

0.17 to 3.33 0.63 to 12.62 0.35 to 7.11 3.33 12.62 7.11

12.1 to 242.2 0.50 to 10.09 242.2 10.09

0.25 to 5.00 0.95 to 18.93 0.53 to 10.66 15.76 to 315.42 5.00 0.35 to 7.08 7.08 18.93 10.66 315.42

18.2 to 363.4 0.76 to 15.14 12.64 to 252.36 363.4 15.14 252.36

1.34 to 26.8 0.76 to 15.10 22.36 to 446.88 26.8 15.10 446.88

25.7 to 514.8 1.07 to 21.45 17.92 to 357.50 514.8 21.45 357.50

*pump supplied with injection check valve for 26-100 psi applications

NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

11

Outputs 100 MDC series


Determining Output for Dual Head Dual Control Models The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. The turndown ratio is 20:1. On the MDC models, the outer pump head operates on a percentage of the inner head (closest to the motor). Setting #10 on both pump heads will deliver the pumps maximum output and is the only time each pump head will output the same amount. Example Using 100MDC5 Decide on the desired output for the inner head. Note the setting on the dial ring that represents the desired output. For example setting #4 = 40% of max output In the 100MDC5 model, setting #4 = 20 GPD Repeat the above steps to calculate the output of the outer head. Using setting #3 in this example, #3 = 30% of the inside head output 20 GPD x 30% = 6 GPD In this example using pump model 100MDC5, the output for the inside head would be 20 GPD and 6 GPD for the outside head.

12

www.stenner.com

Outputs 100 MDC series


Outputs for Inner Pump Head Only
Approx. Outputs @ 60 Hz
Dual Head Dual Control Model Adjustable 100MDCHP5* 100MDC1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. (20:1 Turndown Ratio)

Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute

100 psi/6.9 bar 25 psi/1.7 bar

#1 #1 #2 #2 #3 #4 #5

0.2 to 3.0 0.2 to 3.0 0.5 to 10.0 0.5 to 10.0 1.1 to 22.0 1.7 to 35.0 2.5 to 50.0

0.8 to 11.4 0.8 to 11.4 1.9 to 37.9 1.9 to 37.9 4.2 to 83.3 6.4 to 132.5 9.5 to 189.3

0.01 to 0.13 0.01 to 0.13 0.02 to 0.42 0.02 to 0.42 0.05 to 0.92 0.07 to 1.46 0.10 to 2.08

0.03 to 0.48 0.03 to 0.48 0.08 to 1.58 0.08 to 1.58 0.18 to 3.47 0.27 to 5.52 0.40 to 7.89

0.02 to 0.27 0.02 to 0.27 0.04 to 0.89 0.04 to 0.89 0.10 to 1.96 0.15 to 3.11 0.22 to 4.44

0.56 to 7.92 0.56 to 7.92 1.32 to 26.32 1.32 to 26.32 2.92 to 57.85 4.44 to 92.01 6.60 to 131.46

0.6 to 9.1 0.6 to 9.1 1.5 to 30.3 1.5 to 30.3 3.3 to 66.6 5.1 to 106.0 7.6 to 151.4

0.03 to 0.38 0.03 to 0.38 0.06 to 1.26 0.06 to 1.26 0.14 to 2.78 0.21 to 4.42 0.32 to 6.31

0.42 to 6.32 0.42 to 6.32 1.04 to 21.04 1.04 to 21.04 2.29 to 46.25 3.54 to 73.61 5.28 to 105.14

100MDCHP20* 100 psi/6.9 bar 100MDC2 25 psi/1.7 bar 100MDC3 100MDC4 100MDC5 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar

*pump supplied with injection check valve for 26-100 psi applications

NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

13

Outputs 170 MDC series


Determining Output for Dual Head Dual Control Models The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. The turndown ratio is 20:1. On the MDC models, the outer pump head operates on a percentage of the inner head (closest to the motor). Setting #10 on both pump heads will deliver the pumps maximum output and is the only time each pump head will output the same amount. Example Using 170MDCHP34 Decide on the desired output for the inner head. Note the setting on the dial ring that represents the desired output. For example setting #8 = 80% of max output In the 170MDCHP34 model, setting #8 = 13.6 GPD Repeat the above steps to calculate the output of the outer head. Using setting #6 in this example, #6 = 60% of the inner head output 13.6 GPD x 60% = 8.5 GPD In this example using pump model 170MDCHP34, the output for the inner head would be 13.6 GPD and 8.5 GPD for the outer head.

14

www.stenner.com

Outputs 170 MDC series


The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates 10% increments of maximum output. (20:1 Turndown Ratio)

Outputs for Inner Pump Head Only


Approx. Outputs @ 60 Hz
Dual Head Dual Control Model Adjustable 170MDCHP9* 170MDC1 Maximum Pressure Pump Tube Number gallons per day liters per day gallons per hour liters per hour ounces per minute milliliters per minute

Approx. Outputs @ 50 Hz
liters per day liters per hour milliliters per minute

100 psi/6.9 bar 25 psi/1.7 bar

#1 #1 #2 #2 #3 #4 #5

0.3 to 5.0 0.3 to 5.0 0.8 to 17.0 0.8 to 17.0 2.0 to 40.0 3.0 to 60.0 4.3 to 85.0

1.1 to 18.9 1.1 to 18.9 3.0 to 64.4 3.0 to 64.4 7.6 to 151.4 11.4 to 227.1 16.3 to 321.8

0.01 to 0.21 0.01 to 0.21 0.03 to 0.71 0.03 to 0.71 0.08 to 1.67 0.13 to 2.5 0.18 to 3.54

0.05 to 0.79 0.05 to 0.79 0.13 to 2.68 0.13 to 2.68 0.32 to 6.31 0.48 to 9.46 0.68 to 13.40

0.03 to 0.44 0.03 to 0.44 0.07 to 1.51 0.07 to 1.51 0.18 to 3.55 0.27 to 5.33 0.38 to 7.55

0.76 to 13.13 0.76 to 13.13 2.08 to 44.65 2.08 to 44.65 5.27 to 105.14 7.92 to 157.71 11.32 to 223.40

0.9 to 15.1 0.9 to 15.1 2.4 to 51.5 2.4 to 51.5 6.1 to 121.1 9.1 to 181.7

0.4 to 0.63 0.4 to 0.63 0.10 to 2.15 0.10 to 2.15 0.25 to 5.05 0.38 to 7.57

0.63 to 10.49 0.63 to 10.49 1.67 to 35.76 1.67 to 35.76 4.24 to 84.10 6.32 to 126.18

170MDCHP34* 100 psi/6.9 bar 170MDC2 25 psi/1.7 bar 170MDC3 170MDC4 170MDC5 25 psi/1.7 bar 25 psi/1.7 bar 25 psi/1.7 bar

13.0 to 257.4 0.54 to 10.73 9.03 to 178.75

*pump supplied with injection check valve for 26-100 psi applications

NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

15

Materials of Construction
All Housings* . . . . . . . . . . . . . . . . . Lexan Polycarbonate Plastic Peristaltic Tube** . . . . . . . . . . . . . . Santoprene FDA Approved Check Valve Duckbill Peristaltic Tube . . . . . . . . . . . . . . . Tygothane FDA Approved Check Valve Duckbill . . . . . . . . . . Pellathane Suction/Discharge Tubing . . . . . . . . LDPE Polyethylene-NSF/FDA Approved Ferrules (1/4" & 6mm) Tube Fittings . . . . . . . . . . . . . . . . . Type 1 Rigid PVC-NSF Listed Connecting Nuts Check Valve Fittings Weighted Suction Line Strainer All Fasteners . . . . . . . . . . . . . . . . . Stainless Steel
*Lexan is a registered trademark of General Electric. Consult General Electric for chemical resistance of Lexan. **Santoprene is a registered trademark of Advanced Elastomer System, Akron, OH.

Tygothane is a registered trademark of Saint-Gobain Performance Plastics, Pittsburgh, PA. Pellathane is a registered trademark of The Dow Company, Midland, MI.

16

www.stenner.com

Accessory Checklist pre-installation


25 psi unit includes: (3) Connecting Nuts (1/4" or 3/8") (3) Ferrules w/1/4" & 6mm or (2) Ferrules w/3/8" (1) Injection Fitting (1) Weighted Suction Line Strainer 1/4", 3/8" or 6mm (1) 20' Roll of Suction & Discharge Tubing 1/4" or 3/8" white or UV black OR 6mm (Europe) white (1) Spare Pump Tube (1) Mounting Bracket (1) Installation Manual 100 psi unit includes: (3) Connecting Nuts (1/4" or 3/8") (3) Ferrules w/1/4" & 6mm or (2) Ferrules w/3/8" (1) Injection Check Valve (1) Weighted Suction Line Strainer 1/4", 3/8" or 6mm (1) 20' Roll of Suction & Discharge Tubing 1/4" or 3/8" white or UV black OR 6mm (Europe) white (1) Spare Pump Tube (1) Mounting Bracket (1) Installation Manual

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

17

Installation additional safety instructions


NOTICE: Indicates special instructions or general mandatory action. Read all safety hazards before installing or servicing the pump. The pump is designed for installation and service by properly trained personnel. Use all required personal protective equipment when working on or near a chemical metering pump. Install the pump so that it is in compliance with all national and local plumbing and electrical codes. Use the proper product to treat potable water systems, use only chemicals listed or approved for use. Install the pump to work in conjunction with pool, spa, well pump, or system controls.

18

www.stenner.com

Installation

continued

mount pump
MOUNT PUMP
1. Use the mounting bracket as a template to drill pilot holes in mounting location. 2. Secure bracket with fasteners or wall anchors. Slide pump into bracket.
Provide 8" clearance to allow pump orientation to be reversed during tube replacement. Do not allow water intrusion into the motor or corrosion and damage will occur. To prevent motor damage, verify with a volt meter that the receptacle voltage corresponds with the pump voltage.
Rain roof (optional) slips onto wall bracket

Select a dry location (to avoid water intrusion and pump damage) above the solution tank. Best recommended location is above the solution tank in a vertical position with the pump head pointed downward and the spill recovery (see next page) in place to reduce the risk and severity of damage. To prevent pump damage in the event of a pump tube leak, never mount the pump vertically with the pump head up. To avoid chemical damage from fumes, do not mount pump directly over an open solution tank. Keep tank covered. Avoid flooded suction or pump mounted lower than the solution container. Draw solution from the top of the tank. If pump is installed with a flooded suction, a shut-off valve or other device must be provided to stop flow to pump during service.

Wall bracket

3. Plug cord into receptacle and turn the motor power switch on. If the pump is adjustable, turn the dial ring to 10. 4. Activate the pump by the pump control (flow switch, pressure switch, etc.) and verify rotation of the roller assembly within the clear pump head. Turn pump switch off.
Pump head

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

19

Installation
Additional Installation Instructions 1. All Class II Pumps located
in Zone 1 of swimming pool areas require locating where flooding cannot occur.

continued

additional instructions for CE pumps


Instructions Supplmentaires dInstalltion 1. Toutes les pompes
installes dans la Zone 1 du primtre de la piscine doivent tre situes de manire ne pas pouvoir tre inondes.

Zustazliche Installierungsanweisung un 1. Pumpen die sich in Zone 1


vom Schwimmbecken befinden sollen sind so einzurichten da Ueberschwemmungen nicht vorkommen werden.

Instucciones Adicionales Para instalacin 1. Todas las bombas Clase II


situadas en la Zona 1 de las reas de la piscina requieren colocarse donde no puedan ser inundadas.

Istruzioni Supplementari Per L installazione 1. Tutte le pompe Classe II


localizzate nella Zona 1 della superficie circostante la piscina devono essere collocate dove gli allagamenti no possono accadere.

2. This pump is intended to


be installed as fixed as opposed to portable.

2. Diese Pumpe ist als fest


montierte Ausrustung bedacht und soll nicht umstellbar gebraucht werden.

2. Esta bomba es para ser


instalada fija en vez de porttil.

2. Cette pompe est prvue


pour installation fixe et non pas portative.

2. Questa pompa, inteso,


deve essere installata come fissa e non come portatile.

3. The Rain Roof must be


installed and vertical orientation mounting of entire unit observed.

3. Es necesario instalar el
techo de lluvia, y montar la unidad entera siguiendo una orintacin vertical.

3. Labri anti-pluie doit tre


install et lorientation verticale doit toujours tre observe.

3. Der Regendach muss


installiert werden. Eine vertikale Asrichtung der Montage mu erzielt werden.

3. La tettoia deve essere


installata e il montaggio orientazione verticale dellintera unit deve essere osservato.

4. After installation, the


power supply plug must be accessible during use.

4. Aprs linstallation, la
prise lectrique doit rester accessible pendant lutilisation.

4. Depus de la instalacin
el enchufe suministrador de energia debe estar accesible durante el uso.

5. This unit must be


scrapped if the supply cord is damaged.

4. Die Stromversorgung muss


nach der Installierung noch zuganglich sein.

4. Dopo linstallazione, la
spina deve essere accessibile durante luso.

6. Observe and comply with


all National Wiring Standards.

5. Cette unit doit tre mise


au rebut si le cordon lectrique est endommag.

5. Se deber desechar la
unidad si el cordn de abastecimiento se deteriora.

5. Bei beschadigter
Verkabelung ist dieses Gerat nicht mehr zu gebrauchen.

5. Questa unit deve essere


gettata via se il filo elettrico danneggiato.

6. Observez et adhrez
toutes les Normes Nationales pour Installations Electriques.

6. Observe y cumpla con


todas las Reglas Nacionales para Instalaciones Elctricas.

6. Osservare e aderire a
tutte le Norme Nazionali Sugli Impianti Elettrici.

6. Staatliche
Vernetzungsvorchriften mussen eingehalten werden.

20

www.stenner.com

Installation Diagram
Rain roof slips onto slots in the wall mounting bracket. (No tools necessary) On/Off Switch (Under roof not visible this view)

Always use rain roof for outdoor use or if metering pump is subject to washdowns.

Grounded Power Outlet (GFIC recommended)

Wall Mounting Bracket (Requires 2 screws) IN (Suction) Shut-Off Valve OUT (Discharge)

Disassembled View

Duckbill Disassembled View

Injection Check Valve

Injection Tube

Injection Fitting 0-25 psi Injection Check Valve 26-100 psi

Solution Tank

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

21

Installation

continued

spill recovery
SPILL RECOVERY

In case of tube rupture, chemical drains back into solution tank, preventing spillage onto ground/floor and stops chemical from collecting in tube housing.
Spill Recovery Tube Spill recovery tube drains solution back to tank.

Partial hole is punched through with a #2 Phillips head screwdriver. 1/4" plastic spill recovery tube is inserted in hole. Use section of suction/discharge tubing.

Strainer w/weight

22

www.stenner.com

Installation

continued

suction line
3. Finger tighten nut to the threaded tube fitting while holding the tube fitting.
Over tightening the ferrule and nut with a wrench may result in damaged fittings, crushed ferrules, and air pickup. Do not use thread sealant tape on pump tube connections or tools to tighten connections.
DO NOT use Teflon tape on pump tube threads. DO NOT use pliers.

INSTALL SUCTION LINE


1. Uncoil the suction line and cut a section to assure that the end will be 2-3" above the bottom of the solution tank. Use the outside of the solution tank as a guide to cut to proper length.
Allow sufficient slack to avoid kinks and stress cracks. Always make a clean square cut to assure that the suction line is burr free. Normal maintenance requires trimming. Suction lines that extend to the bottom of the tank can result in debris pickup leading to clogged injectors and possible tube failure.

More on next page

2. Slide the suction line through the connecting nut and ferrule and fully insert the line into the bottom pump tube fitting as indicated by the IN on the tube housing cover.

Finger tighten nut

OUT

Ferrules Suction line

Note: Beveled ends of ferrules face pump. Tubing should bottom into all fittings.

IN

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

23

Installation

continued

suction line
4. Drill a 17/64" hole into the lid or bung cap of the solution tank. Secure strainer weight to the end of the suction line as per provided instructions and feed it into the hole. Suspend 2-3" above the tank bottom.

5.

Strainer w/weight

Do not mix chemicals in the solution container. Follow recommended mixing procedures according to the manufacturer.

Do not operate pump unless chemical is completely in solution. Turn pump off when replenishing solution.

Strainer w/weight (closeup view)

Strainer w/weight (disassembled view)

24

www.stenner.com

Installation

continued

discharge line
Locate a point of injection beyond all pumps and filters or as determined by the application.
DO NOT use Teflon tape on pump tube threads. DO NOT use pliers.

INSTALL DISHARGE LINE


1. Make a secure finger tight connection on the discharge fitting of the pump head as instructed in Install Suction Line instructions.
Do not use thread sealant tape on pump tube connections or tools to tighten connections.

2. A 1/4" or 1/2" female NPT connection is required for the injection fitting. If there is no FNPT fitting available, provide one by either tapping the pipe or installing FNPT pipe tee fitting. 3. Wrap MNPT end of injection fitting with 2 to 3 turns of threading tape. If necessary trim straight-sided extension tip so it is in the flow of water. See Illustration 4. Tighten the injection fitting into the FNPT fitting.

HAZARDOUS PRESSURE:
Shut off water or circulation system and bleed off any system pressure.

Trimming Check Valves

More on next page

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

25

Installation

continued

discharge line
The injection point and fitting require periodic maintenance to clean any deposits or buildup. To allow quick access to the point of injection, Stenner recommends the installation of shut-off valves.

Typical Point of Injection


Shut-Off Valve

Injection Check Valve

1/4'' or 1/2'' FNPT Reduction Bushing

26-100 psi models: Prior to making tubing connection, test check valve and NPT threads for leaks by pressurizing system. Tighten an additional 1/4 turn if necessary. Make final tube connection as instructed in Install Suction Line instructions.

0-25 psi models: Low-pressure models do not have a check valve and check valve body. Insert the tubing 3/4" to 1" into the injection fitting and make tubing connection as instructed in Install Suction Line instructions. 5. Turn pump switch on and observe chemical flow as actuated by system. 6. After a suitable amount of dosing time, perform tests for required chemical levels. If necessary, fine-tune dosing levels by rotating dial ring (adjustable pumps only).

HAZARDOUS PRESSURE:
Shut off water or circulation system and bleed off any system pressure.

26

www.stenner.com

Troubleshooting motor
PROBLEM
Motor

POSSIBLE CAUSE
HAZARDOUS VOLTAGE:

SOLUTION

DISCONNECT power cord before removing motor cover for service. Electrical service should be by trained personnel only. Noise is excessively loud. Ball bearings are worn. Lubrication is insufficient. Gears or gear posts are worn. Motor does not work; fan is not turning. Electrical supply is faulty. Rotor bound to coil. Motor coil is damaged. Motor bearings are worn or damaged. Power cord is damaged. Rotor rusted to coil. Wire connections are faulty. Fan is obstructed. Motor runs; fan turns; output shaft does not. Motor overheats and shuts off and on. Check all gears. Voltage is incorrect. Ambient temperature is high. Coil is damaged/malfunctioning. Phenolic gear is stripping. Water intrusion. Cracked bearing bracket. Gear posts worn. Rusted helical gear at end of rotor. Worn gear case cover. Insufficient lubrication. Replace rotor assembly. Grease gears and gear posts. Inspect/replace gears and gear posts. Check supply voltage circuit. Check bearing brackets for cracks and replace if necessary. Replace motor coil. Replace rotor assembly. Inspect/replace power cord. Clean off coil and rotor or replace as needed. Inspect/repair electrical connections. Remove obstruction. Replace gears as needed. Check that voltage and frequency match data label. Install pump in an area not to exceed a maximum of 125 F. Replace motor coil. Use rain roof. Replace bearing bracket. Replace gear posts. Buff off rotor or replace rotor. Replace gear case cover. Lubricate with AquaShield.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

27

Troubleshooting
PROBLEM
Feed Rate Control
Adjustment ring will not turn.

continued

feed rate control


SOLUTION
Grease variable cam and cam slot. Clean and lubricate ring. Re-insert 90 end into ring. Replace variable cam. Turn over or replace index plate. Refer to Motor Section. Replace roller assembly. Tighten holder into spider assembly. Replace index pin and lifter assembly. Replace or re-insert variable cam. Turn over or replace index plate. Replace variable cam. Replace index pin and lifter assembly.

POSSIBLE CAUSE
Variable cam has seized. Adjustment ring has seized.

Adjustment ring turns, output doesnt change.

Variable cam has disengaged from ring. Variable cam is broken.

Pump head is not rotating.

Index plate is worn. Problem with the gear motor. Pump head roller assembly is stripped. Index pin holder backed out of spider assembly. Index pin is broken.

Pump head rotates continuously. Indexing is erratic.

Variable cam is installed incorrectly. Index plate is worn. Variable cam is worn. Lifter is worn.

28

www.stenner.com

Troubleshooting
PROBLEM
Pump Head
Components are cracking. Visible fluid in pump head. No pump output; pump head rotates.

continued

pump head
SOLUTION
Check chemical compatibility. Replace pump tube and ferrules and center tube. Replenish solution. Maintain suction line 2-3" off bottom of tank. Inspect or replace suction line. Replace compression ferrules. Inspect and clean injection point. Clean and/or replace as necessary. Replace pump tube. Replace pump tube. Install new rollers or roller assembly. Inspect and clean injection point. Check tube psi rating against system pressure; replace accordingly. Replace roller assembly. Refer to Feed Rate Control section. Refer to Motor section. Replace tube with correct size. Replace roller assembly. Refer to Feed Rate Control section. Replace with proper motor.

POSSIBLE CAUSE
Chemical attack. Pump tube rupture/leak. Depleted solution tank. Pump suction line weight is above solution. Suction line leak. Ferrules installed incorrectly or damaged. Injection point is clogged. Clogged suction/discharge tubing and/or injection check valve. Life of pump tube is exhausted.

Low pump output; pump head rotates.

Pump tube is worn. Rollers missing or cracked. Injection point is restricted. High system back pressure.

No pump output; pump head not rotating.

Roller assembly is stripped. Feed Rate Control problem. Motor problem.

Pump output is high.

Incorrect tube size. Roller assembly is broken. Malfunctioning Feed Rate Control. Incorrect model of motor.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

29

Troubleshooting
PROBLEM
Pump Tube
Tube is leaking.

continued

pump tube
SOLUTION

POSSIBLE CAUSE

NOTICE: A leaking pump tube damages the metering pump. Inspect pump frequently for leakage
and wear. Refer to Tube Replacement section for additional safety precautions and instructions. Pump tube has ruptured. Calcium or mineral deposit. Excessive back pressure. Tube is twisted. Tube is not centered. Replace pump tube at routine intervals. Clean injection fitting, replace pump tube. Check tube psi rating against system pressure; replace accordingly. Replace tube according to instructions. Replace tube and center it. Check chemical compatibility. Remove deposit and replace pump tube. Maintain suction line 2-3" above bottom of tank. Use a suction line strainer. Replace check valve duckbill at every tube change. Reverse duckbill orientation. See tube replacement instructions. Allow roller assembly to stretch tube into place. Clean roller assembly or replace.

Tube life is shortened.

Chemical attack. Mineral deposit at injection point. Sediment blockage at check valve. Degraded check valve duckbill. Duckbill in wrong orientation. Tube was manually stretched to lock into discharge side slot. Seized rollers caused abrasion on tube.

30

www.stenner.com

Tube Replacement safety information


RISK OF CHEMICAL EXPOSURE: To reduce risk of exposure, check the pump tube regularly for leakage. At the first sign of leakage, replace the pump tube. To reduce risk of exposure, the use of proper personal protective equipment is mandatory when working on or near chemical metering pumps. To reduce risk of exposure, and also prior to service, shipping, or storage, pump generous amounts of water or a compatible buffer solution to remove chemical from pump. Consult chemical manufacturer and MSDS sheet for additional information and precautions for the chemical in use. Personnel should be skilled and trained in the proper safety and handling of the chemicals in use. PINCH POINT HAZARD: Use extreme caution when replacing pump tube. Be careful of your fingers and DO NOT place fingers near rollers. HAZARDOUS PRESSURE/CHEMICAL EXPOSURE: Use caution and bleed off all resident system pressure prior to attempting service or installation. Use caution when disconnecting discharge tubing from pump. Discharge may be under pressure. Tubing may contain chemical.

NOTICE: Indicates special instructions or general


mandatory action.

NOTICE: DO NOT apply grease, oil, or lubricants to the pump tube or housing. NOTICE: Prior to pump tube replacement, inspect the entire
pump head for cracks or damaged components. Ensure rollers turn freely.

NOTICE: Rinse off chemical residual and clean all chemical and debris from pump head components prior to tube replacement. Apply Stenner grease to main shaft and tube housing cover bushing during tube replacement. NOTICE: DO NOT pull excessively on pump tube. Avoid
kinks or damage during tube installation.

NOTICE: Inspect the suction/discharge tubing, injection point


(into pipe), and injection check valve duckbill for blockages after any tube rupture. Clear or replace as required.
US and Canada call 1.800.683.2378, other countries call 1.904.641.1666 31

Tube Replacement

continued

preparation
4. Disconnect the suction and discharge connections from pump head. 5. Plug power cord into constantly energized, properly grounded receptacle for service.

1. Follow all safety precautions prior to tube replacement. 2. Prior to service, pump water or a compatible buffer solution through the pump and suction/discharge line to remove chemical and avoid contact. 3. Turn pump off.

32

www.stenner.com

Tube Replacement
1. Remove and set aside cover and screws. 2. Set feed rate dial on the low setting until finished. 3. Turn pump on and let it run until one of three roller assembly slots lines up with the tube fitting on the suction side. Illustration A 4. Turn pump off. 5. Lift tube fitting out of housing slot and pull it toward center of roller assembly. Illustration B 6. Turn pump on and allow roller assembly to jog while guiding tube, with tension, up and out of housing. Illustration C 7. Turn pump off. Remove and discard pump tube.

continued

remove old tube


A

REMOVE OLD TUBE


8. Remove roller assembly, shaft, and housing. 9. Use non-citrus all-purpose cleaner to clean chemical residue from pump head housing, roller, and cover. 10. Check housing for cracks. Replace if cracked. 11. Ensure rollers spin freely. Illustration D 12. Replace roller assembly if: seized, excessive side play from bore wear, or if rollers are visibly worn. 13. Reinstall clean tube housing. 14. Grease shaft tip and install. 15. Install roller assembly.

Pull Out

Pull Out

Check Rollers

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

33

Tube Replacement
IMPORTANT! Do not lubricate pump tube or roller assembly.

continued

install new tube


INSTALL NEW TUBE
5. When tube reaches the top housing slot, turn pump off. 6. Turn dial ring to setting 10, hold tube fitting firmly, and turn pump on. NOTE: A used tube will have stretched approximately 3/4" and the new tube will appear to be stiff and short. Follow directions to allow rollers to stretch tube into place. 7. Allow rollers to stretch tube into place while guiding tube into slot. Illustration G 8. Turn pump off. 9. Apply a small amount of grease (AquaShield) to cover bushing ONLY and replace cover and two screws, leaving front screw in-between the fittings loose.

1. By manually rotating the roller assembly counter clockwise, align one of three roller assembly slots with the suction side housing slot.
Tube Housing Slot Roller Assembly Slot

2. Place tube fitting into suction side slot of the housing and the roller assembly slot. Illustration E 3. With pump setting on low, hold tube fitting and jog roller assembly by turning pump on.

Guide

Turn the pump on, walk tube in.

G
Guide

IMPORTANT! Avoid rotating wrist, which can result in a twisted tube that will not center. Do not force tube and be careful of your fingers. 4. Guide tube, with slight tension (toward the center) to prevent pinching between housing and roller assembly. Illustration F

Tube Housing Slot

Roller Assembly Slot

NOTE: Cover screws are self-tapping and must be backed in to locate original thread before securing. If a screw boss is stripped, use alternate bosses and position opposite from each other. Never secure the cover plate with more than 2 screws.

34

www.stenner.com

Tube Replacement
1. To center pump tube on rollers, set feed rate dial to setting 10. Turn pump on. Illustration H 2. Turn the tube fitting on the suction side not more than 1/8 of a turn in the direction tube must move.

continued

center new tube


H
1/8 Turn

CENTER NEW TUBE


3. Do not let go of fitting until tube rides approximately in center of rollers. 4. Turn pump off, let go of fitting, and tighten cover screws. Cover is not on securely if there is a gap between screw boss and cover.

Leave this screw loose.

TUBE CHANGE FOR FIXED OUTPUT PUMP


1. To install a new tube in a fixed output pump, follow the instructions above and utilize the on/off switch to jog the roller assembly in the absence of the feed rate control. Illustration I

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

35

Motor exploded view


Motor Cover with cord Coil Screw G w/Lock Washer
Strain Relief Bushing

Power Cord Rotor Assembly with Bearings, Brackets, Tolerance Rings & Fan Gear Case Gear Post Phenolic Gear Phenolic Gear Spacer

Rain Roof

Gear Case Cover

On-Off Switch Plate

Coil

Pressure Spring
(adjustable models only)

Toggle Switch

Switch Boot Motor Base Mounting Bracket

Thrust Washer Metal Reduction Gear

Motor Shaft Cover Screw B

36

www.stenner.com

Motor
MOTORS
DESCRIPTION

continued

subassemblies
PART NUMBER
(120v) PM6041D (120v) PM6081D (120v) ME6041D (120v) ME6081D (120v) DM6041D (120v) DM6081D

UM
EA EA EA EA EA EA

PART NUMBER
(220v) PM6042D (220v) PM6082D (220v) ME6042D (220v) ME6082D (220v) DM6042D (220v) DM6082D

UM
EA EA EA EA EA EA

Motor 60Hz (adjustable output 45 & 100 series) Motor 60Hz (adjustable output 85 & 170 series) Motor 60Hz (fixed output 45MP series only) Motor 60Hz (fixed output 85MP series only) Motor 60Hz (fixed output 100DMP series only) Motor 60Hz (fixed output 170DMP series only)

EUROPE
Motor 50Hz (adjustable output 45 & 100 series) Motor 50Hz (adjustable output 85 & 170 series) Motor 50Hz (fixed output 45MP series only) Motor 50Hz (fixed output 85MP series only) Motor 50Hz ((fixed output 100DMP series only) Motor 50Hz (fixed output 170DMP series only) (230v) PM64230 (230v) PM68230 (230v) ME64230 (230v) ME68230 (230v) DM64230 (230v) DM68230 EA EA EA EA EA EA (250v) PM6426D (250v) PM6826D (250v) ME6426D (250v) ME6826D (250v) DM64250 (250v) DM68250 EA EA EA EA EA EA Motor

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

37

Motor

continued

service kits
MOTOR SERVICE KITS
DESCRIPTION
Motor Service Kit 60Hz

Motor Service Kit


Wire Nuts Coil
Coil

Coil Screw G w/Lock Washer Coil Ground Screw E

PART NUMBER
(120v) MSK120

UM
Kit

PART NUMBER
(220v) MSK220

UM
Kit

Rotor Assembly w/Bearings, Brackets, Tolerance Rings & Fan

GEAR CASE SERVICE KITS


Gear Case Service Kit
AquaShield

DESCRIPTION
Gear Case Service Kit (adjustable output 45 & 100) Gear Case Service Kit (adjustable output 85 & 170) Gear Case Service Kit (fixed output 45MP series only) Gear Case Service Kit (fixed output 85MP series only)

PART NUMBER
GSK45A GSK85A GSK45F GSK85F

UM
Kit Kit Kit Kit

Phenolic Gear w/Spacer Motor Shaft w/Gear

Metal Reduction Gear Gear Posts Cover Screw B

38

www.stenner.com

Feed Rate Control exploded view


FRC Screw Index Pin Spring Index Pin Feed Rate Housing Index Plate O-Ring Seal Index Pin Lifter Main Shaft Single Head/ Adjustable Output Mounting Rivet

Index Pin Holder

Feed Rate Mounting Plate Dial Ring

Index Spider Variable Cam

Roller Clutch

Main Shaft Double Head/Adjustable Output Main Shaft Dual Head Dual Control/Adjustable Output

Contact factory for part numbers.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

39

Feed Rate Control


Feed Rate Control

continued

subassemblies & service kits


PART NUMBER
FC5040D DM5040D DM504DC

FEED RATE CONTROLS


DESCRIPTION
Feed Rate Control w/ shaft (single head 45/85 adjustable) Feed Rate Control w/ shaft (double head 100/170 adjustable) Feed Rate Control w/shaft (dual head dual control 100/170MDC)

UM
EA EA EA

Feed Rate Control Service Kit


AquaShield Index Plate

FEED RATE CONTROL SERVICE KIT


DESCRIPTION
Screw A

PART NUMBER
FSK100

UM
Kit

Feed Rate Control Service Kit

Lifter

Variable Cam

40

www.stenner.com

Pump Head exploded view


Tube Housing

Roller Housing Pump Tube Tube Housing Cover Cover Screw B

Roller

Contact factory for part numbers.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

41

Pump Head
Pump Head

continued

subassemblies
PUMP HEADS
DESCRIPTION
Pump Head includes SANTOPRENE pump tube; ferrules 1/4" Pump Head includes SANTOPRENE pump tube & duckbill; ferrules 1/4" Pump Head includes TYGOTHANE pump tube; ferrules 1/4" Pump head includes TYGOTHANE #2 pump tube; PELLATHANE duckbill; ferrules 1/4"

PART NUMBER

UM

PART NUMBER UM
PK of 2 n/a n/a n/a

UCTHC * D EA MCTHC * D * select tube number 1, 2, 3, 4, 5, 7 UCPH * FD EA n/a * select tube number 1, 2, 7 UCPHT0 * EA * select tube number 2, 5 UCPHTD2 EA n/a n/a

EUROPE Pump Tube Numbers #1 and #2 for 26-100 psi pump (when used with check valve). #1, 2, 3, 4, 5 for 0-25 psi pump. #7 tube for 26-100 psi single head pump only.
Pump Head includes SANTOPRENE pump tube; ferrules 6mm Pump Head includes SANTOPRENE pump tube & duckbill; ferrules 6mm Pump Head includes TYGOTHANE pump tube; ferrules 6mm Pump head includes TYGOTHANE #2 pump tube; PELLATHANE duckbill; ferrules 6mm UCTH * CE EA MCTH * CE * select tube number 1, 2, 3, 4, 5, 7 UCPH * CE EA n/a * select tube number 1, 2, 7 UCPHT * CE EA * select tube number 2, 5 UCPHD2CE EA n/a n/a PK of 2 n/a n/a n/a

42

www.stenner.com

Pump Head
DESCRIPTION

continued

service kits
UM
PSKL0_*_ KIT * select tube number 1, 2, 3, 4, 5 PSKH0_*_ KIT * select tube number 1, 2, 7 PSKLT * KIT * select tube number 2 or 5 PSKHT2 KIT
Pump Tube

PUMP HEAD SERVICE KITS


PART NUMBER
SANTOPRENE Kit (0-25 psi) SANTOPRENE Kit (26 - 100 psi) TYGOTHANE Kit (0-25 psi) KIT: (26-100 psi) TYGOTHANE #2 Pump Tube & PELLATHANE duckbill included 0-25 psi/1.7 bar
Roller Assembly Connecting Nuts 1/4" Ferrules 1/4" or 6mm Europe Cover Screw B

EUROPE
SANTOPRENE Kit (1.7 bar) SANTOPRENE Kit (1.7-6.9 bar) TYGOTHANE Kit (1.7 bar) KIT: TYGOTHANE #2 Pump Tube & PELLATHANE duckbill included

PSKL * CE KIT * select tube number 1, 2, 3, 4, 5 PSKH * CE KIT * select tube number 1, 2, 7 PSKLT * CE KIT * select tube number 2 or 5 PSKHT2CE KIT

26-100 psi/6.9 bar


Roller Assembly Connecting Nuts 1/4" Duckbill Ferrules 1/4" or 6mm Europe
Cover Screw B

Pump Tube

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

43

Adapter Pump Heads subassemblies


ADAPTER PUMP HEADS
DESCRIPTION
Adapter Pump Head includes SANTOPRENE pump tube; ferrules 1/4" Adapter Pump Head includes SANTOPRENE pump tube & duckbill; ferrules 1/4" Adapter Pump Head Adapter Pump Head includes TYGOTHANE pump tube; ferrules 1/4" Adapter Pump Head includes #2 TYGOTHANE pump tube PELLATHANE duckbill; ferrules 1/4"

PART NUMBER

UM

PART NUMBER UM
PK of 2 n/a n/a n/a

UC1ATC * EA MC1ATC * * select tube number 1, 2, 3, 4, 5 UCAH * FD EA n/a * select tube number 1, 2 UCAHT0 * EA n/a * select tube number 2, 5 UCAHTD2 EA n/a

EUROPE
Adapter Pump Head includes SANTOPRENE pump tube; ferrules 6mm Adapter Pump Head includes SANTOPRENE pump tube & duckbill; ferrules 6mm Adapter Pump Head includes TYGOTHANE pump tube; ferrules 6mm Adapter Pump Head includes #2 TYGOTHANE pump tube; PELLATHANE duckbill; ferrules 6mm UCAP * CE EA MCAP * CE * select tube number 1, 2, 3, 4, 5 UCAH * CE EA n/a * select tube number 1, 2 UCAT * CE EA n/a * select tube number 2, 5 UCT2DCE EA n/a PK of 2 n/a n/a n/a

44

www.stenner.com

Pump Tubes
PUMP TUBES
DESCRIPTION
SANTOPRENE Pump Tube ferrules 1/4" SANTOPRENE Pump Tube & duckbill; ferrules 1/4" TYGOTHANE Pump Tube; ferrules 1/4" TYGOTHANE #2 Pump Tube & PELLATHANE duckbill; ferrules 1/4"

PART NUMBER

UM

PART NUMBER UM
PK of 5 n/a PK of 5 n/a

UCCP20 * PK of 2 MCCP20 * * select tube number 1, 2, 3, 4, 5, 7 UCCP * FD PK of 2 n/a * select tube number 1, 2, 7 UCTYG0 * PK of 2 MCTYG0 * * select tube number 2, 5 UCTY2FD PK of 2 n/a

EUROPE
SANTOPRENE Pump Tube ferrules 6mm SANTOPRENE Pump Tube & duckbill; ferrules 6mm TYGOTHANE Pump Tube ferrules 6mm TYGOTHANE #2 Pump Tube & PELLATHANE duckbill; ferrules 6mm UCCP2 * CE PK of 2 MCCP2 * CE * select tube number 1, 2, 3, 4, 5, 7 UC * FDCE PK of 2 n/a * select tube number 1, 2, 7 UCTY * CE PK of 2 MCTY * CE * select tube number 2, 5 UCTY2DCE PK of 2 n/a PK of 5 n/a PK of 5 n/a

Pump Tube Numbers #1 and #2 for 26-100 psi pump (when used with check valve). #1, 2, 3, 4, 5 for 0-25 psi pump. #7 tube for 26-100 psi single head pump only.

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

45

Check Valves
CHECK VALVES
DESCRIPTION
Injection Check Valve 1/4" Check Valve includes SANTOPRENE duckbill; ferrules 1/4"

PART NUMBER
UCDBINJ UCTYINJ

UM
EA EA

PART NUMBER UM
MCDBINJ MCTYINJ PK of 5 PK of 5

Check Valve includes PELLATHANE duckbill; ferrules 1/4"

Injection Check Valve 3/8"

Check Valve includes SANTOPRENE duckbill; ferrules 3/8" Check Valve includes PELLATHANE duckbill; ferrules 3/8"

UCINJ38 UCTYIJ38

EA EA

MCINJ38 MCTYIJ38

PK of 5 PK of 5

EUROPE Injection Check Valve 6mm Check Valve includes SANTOPRENE duckbill; ferrules 6mm Check Valve includes PELLATHANE duckbill; ferrules 6mm UCINJCE UCTINJCE EA EA MCINJCE MCTINJCE PK of 5 PK of 5

46

www.stenner.com

For Your Records


Model: Serial Number: Date of Installation:

US and Canada call 1.800.683.2378, other countries call 1.904.641.1666

47

3174 DeSalvo Road Jacksonville, Florida 32246 [email protected] www.stenner.com Phone: 904.641.1666 US Toll Free: 800.683.2378 Fax: 904.642.1012

Metering Pumps Manufactured Since 1957

Hours of Operation (EST): Mon. Thu. 7am 5pm Friday 7am Noon

You might also like