REGULATIONS
SPECIFICATIONS
STANDARDS
CIDA REGULATIONS
IMPORTANT ASPECTS OF
FIRE REGULATIONS
QUESTIONS
CIDA REGULATIONS
There are over 100 regulations in the current document being attended…..
Means of Escape – Areas which are designated as means of escape such as exit
staircase, fire fighting lobby, smoke stop lobby, exit passageway, escape
corridors, shall not be used for any other purpose.
TEAM/INSTITUTES INVOLVED IN PREPARATION OF REGULATIONS/
SPECIFICATIONS OF CIDA
(1) Architects (SLIA)
(2) Association of Consulting Engineers-SL
(3) Institute of Quantity Dept. of Fire Services
(4) Institute of Fire Engineers (IFE) SL Branch
(5) Building Services Engineering Sectional committee of IESL
(6) Lanka Association of Building Service Engineers
(7) Sri Lanka Institute Surveyors - SL
(8) Fire Engineering & Equipment Traders Association ( FEETA)
FIRE REGULATIONS - OVERVIEW
• REGULATOR AND IMPLEMENTING BODY
• CIDA ACT
LIFE SAFETY
2019
2010
2030
• High-Rise Building
Any building greater than 30 m in height and less than 60 m in height, where
building height is measured from the lowest level of fire department vehicle
access to the floor of the highest habitable floor
• The committee shall consist of minimum of five members and the committee
shall,
• Advise the AHJ on any technical matters where such advice is required for taking
a final decision.
• Investigate and recommend corrective actions for violations of and non-
compliances with the regulations brought to the notice of CIDA.
• Investigate and recommend the courses of action to be taken with respect to any
dispute referred to CIDA
CHAPTER 1 - ADMINISTRATION AND APPLICATION
• Owners/occupiers of the designated buildings falling under the categories of super
high rise and high rise buildings which require Fire Risk Assessment as per this
regulation shall be required to produce a report issued by a Qualified Person or body
once in every three years, to demonstrate
• The efficiency of the Fire Protection systems,
• Means of escape and
• Conditions of refuge floors etc
CHAPTER 2 - MEANS OF ESCAPE
• The provisions of this Chapter of this Regulation shall control the design,
construction, protection, location, arrangement and maintenance of required exit
facilities to provide safe means of escape from all new buildings and buildings
altered or changed in occupancy
SMOKE FREE LOBBY - REG. 2(19)
• A lobby that is separated from the adjoining areas of the building by a wall having a
fire resistance as per the building fire rating. The exit access door shall have fire
resistance of half that of the enclosure fitted with automatic self-closing device.
• The purpose of this Chapter of the Regulation is to minimize the risk of the spread of fire
between adjoining buildings by a stable and durable form of construction,
• to prevent the spread of fire between specified parts of buildings by the division of such
buildings into compartments
REFUGE FLOORS REG. 3(21)
• A refuge floor consisting of a refuge area shall be provided for every 10 floors
for buildings having the height of occupiable floors exceeding 60 m.
• Fireman's lift car shall be not less than • Evacuation lift car shall be large enough to
1100 mm wide by 2100mm deep with a accommodate a stretcher or a bed. The load shall
rated load of 1000 Kg. minimum be not less than 1000 kg and the dimensions shall
entrance with 800 mm be minimum 1100 mm wide by 2100 mm deep.
• Lift shall be capable of reaching the • The elevator lobby shall be adequate to
uppermost habitable floor from fire accommodate not less than 50% of the occupant
service access level within 60 seconds. load of the area served by the lobby and also
include one wheel chair space of 760mm x
1220mm for each 50 persons or part thereof.
CHAPTER 4 - FIRE DETECTION AND ALARM SYSTEMS
• The requirements are stated as the minimum requirement to be complied with and
any improvements based on any international standard is accepted provided that
the designer/Installer could justify its performance is superior to what has been
stated in this regulations, to AHJ
CHAPTER 4 - FIRE DETECTION AND ALARM SYSTEMS
One way emergency voice evacuation and communication system and an emergency
command centre shall be provided as follows:
• For all large buildings with gross floor area greater than 2800 m² or having a total
occupant load exceeding 1000 persons and large industrial and warehouse buildings
with gross floor area greater than 5000 m².
• For all buildings which are categorized as high rise and super high rise buildings.
CHAPTER 4 - FIRE DETECTION AND ALARM SYSTEMS
• Two-way telephone communication system with Fire Command Centre (FCC) shall be
provided for all buildings which are categorized as high rise and super high rise buildings
and any other building as requested by AHJ.
• TABLE 17
CHAPTER 5 - FIRE EXTINGUISHING APPLIANCES…
BREACHING INLET ; For high rise and super high rise buildings a breaching inlet shall be
provided to fill the fire suction tank.
Reg. 5(33) -AUTOMATIC SPRINKLER SYSTEMS
• All high rise & Super High Rise Buildings as defined by these
regulations. It should be noted that the sprinklers systems should
cover all storeys including the basements
Reg. 5(31) ;FIRE PROTECTION FOR BUILDING UNDER CONSTRUCTION
All building under construction shall be equipped with following Fire Fighting facility
• A Dry Type rising main shall be installed where the building habitable floor height is less
than 60 meters.
• A WET Type rising main shall be installed where the building habitable floor height is
more than 60 meters
• Breeching inlets (2 way or 4 way) shall be provided and connected to the riser as per
approved building plan
FIRE PUMP INSTALLATIONS FOR SPRINKLER, HYDRANT AND HOSE
REEL SYSTEMS
Reg. 5(49); Separate pumps sets shall be provided for Sprinkler and hydrant
installations other than for combination system.
Pumps, drivers, and controllers
a) Drivers for pumps at a single installation shall be either electric motors or diesel
engines.
b) Fire pumps shall be listed for fire protection services and certified by an
independent testing authority.
c) A pump shall not be equipped with more than one driver.
d) Each fire pump shall have its own dedicated driver
e) Each driver shall have its own independent dedicated controller.
PUMP PERFORMANCE RESULTS ; REG. 5(55)
Sprinkler System flow rate as per the flow rate as per 60lpm/10% of main
sprinkler hazard the sprinkler pump flow rate Where the building is
classification hazard sprinklered the maximum
classification flow rate shall be 2500 l/min.
FIRE PUMP CONFIGURATIONS
• Fire Pumps shall have positive suctions. If this is not feasible, vertical turbine pumps
shall be used.
• Automatic and Manual Operation - The pumps shall start “automatically” on a fall in
pressure or demand in water, and once started automatically shall be stopped only
manually. Facility for starting the pump manually, overriding the automatic controls,
must be available
• Pumps in Operation - An audible and visual alarm shall be installed in the control
room to indicate that the pumps have started.
CHAPTER 6 - SPECIAL USE, OCCUPANCIES AND STRUCTURES
• This chapter of the code shall apply only to those buildings types, uses, occupancies
and structures specifically regulated herein, and the requirements of this chapter
shall be in addition to the general requirements of the other chapters of the
regulation governing the size, location, structural fire precautions, means of escape,
construction, ventilation, fire-extinguishing equipment and other service equipment
of buildings
• Reg.6(32) Separation of Kitchen Area from Dining Area seating area exceeds 75,the
main kitchen area shall be separated from the dining area by a wall having fire
resistance of not less than 1 hour
• Display / show kitchens Reg.6(33) Any display or show kitchen which is not
separated (compartmented) from the restaurant shall be provided with an
automatic fire suppression system.
CHAPTER 7 - ACCESSIBILITY FOR FIRE FIGHTING
Purpose of this Chapter is to ensure provision for external access to
building for fire fighting and accessibility of fire fighting appliances.
• Reg. 7(1) Access way shall be provided for accessibility to site for fire
fighting appliances.
• Hard standing
requirement Reg. 7(2)
CHAPTER 8 - INSPECTION MAINTENANCE AND TESTING OF ACTIVE
/PASSIVE FIRE PROTECTION FACILITIES
• In the event that there are multiple occupants occupying the same
complex, the owner, the condominium management corporation
and/or the organization appointed to maintain and upkeep the
building shall be responsible for the above
SYSTEMS TO BE INSPECTED, MAINTAINED AND TESTED REG. 8(1)
• Fire Detection and Voice Evacuation Systems
• Fire Protection and Suppression Systems
• The Means of Escape
• Smoke Control Systems
• Stairway “pressurization” systems
• Portable Fire Extinguishers
• Exit Signage
• Emergency Lighting
• Total Flooding Systems
• Fuel Gas Leak Detection Systems
• Fire Brigade Access Routes
• Fire Water Storage
SERVICING CONTRACT REG. 8(8)
• Responsible person of the Fire Service Installations (FSI) shall employ a registered
contractor to inspect FSI of their buildings at least once every 12 months
DOCUMENTATION REG. 8(10)