Nivelco Plovak

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Thank you for choosing a NIVELCO instrument.

1. APPLICATION
We are sure that you will be satisfied throughout its use.
NIVOMAG
The NIVOMAG MK-200 series magnetic float level switches are used for level point detection of liquids in all type of
vessels.
Operation without external power, side or top mounting, wide temperature ranges, various process connections, stainless
steel wetted parts and Ex versions make it applicable in the industrial chemistry, pharmacy, petrol industry etc. Permanent
magnet operated by the movement of a float will activate an other magnet inside the switching enclosure. This second
magnet operates a special switch. So the movement of float is transferred to the potted switch through separated magnetic
coupling ensuring the requirements of the wet process and Ex application. Special balancing construction and various
accessories (see figures of DIMENSIONS) give wide range of possibility of the installation.

2. TECHNICAL DATA
2.1 GENERAL SPECIFICATION
VERTICAL
HORIZONTAL FLOAT
TYPE FLOAT
MK-21- MK-22- MKG-2- MKS-2- MK-23-
Nominal Pressure max. 2.5 MPa (MKU: 0.2 MPa / 2.5 MPa) 1.6 MPa
Liquid temperature see temperature diagram 0°C to 100°C 0°C to 200°C s. temp.diagr.
Ambient temperature -20 °C … +80 °C, Ex version see table below
Liquid density min 0.7 kg/dm3 … 0.85 kg/dm3 see table
Switch differential Fixed Adjustable Fixed Fixed Adjustable
Protrusion length See figures below
Material of vetted parts SS316Ti (MKG: rubber MKS silicon rubber)
Housing material Paint coated aluminium
Switch action 1 micro-switch with 1 closing and 1 opening contact (NO and NC)
Switch rating 250 V AC12 10 A; 220 V DC13 0.6 A – Ex:250V AC12 2.5A; 220V DC13 0.3 A
1 x Pg 16 or M20 x 1.5 for cable diameter 6 to 15 mm*
Electrical connection
with 5 x 2.5 mm2 wire cross section (MKU: integrated cable)
Mechanical protection IP 65 (MKU: IP 68 max 20 m water depth) Manufacturer:
Electrical protection Class I. NIVELCO Process Control Co.
H-1043 Budapest, Dugonics u. 11.
Ex protection mark II 1/2 G Ex d e mb IIC T6 … T2 Ga/Gb
Phone: (36-1) 889-0100 Fax: (36-1) 889-0200
Weight (approx) 2.5 kg E-mail: [email protected] www.nivelco.com
* depending on type of cable gland

2.2 SPECIAL DATA


ARM. L. MINIMAL DENSITY OF LIQUID
TEMPERATURE T2
Medium [°C]
250
T3 200 (mm) (kg/dm3)
CLASS T6 T5 T4 T3 T2 T4 FLOAT
130
T5 100 0 … 100 200 300 1000 … 3000
Liquid T6 80 (mm)
+80 °C +95 °C +130 °C +200 °C +250 °C MKU
temperature 52 0.7 0.8 0.85 –
Ambient -20 °C … -20 °C … -20 °C … -20 °C … -20 °C … 20 -12
-20
60 70 80 Ambient
[°C]
64 0.7 0.8 0.8 –
temperature +60 °C +70 °C +80 °C +80 °C +80 °C -50 120 – – – 0.7

2.3. ACCESSORIES
− User’s Manual, Warranty Card, Declaration of conformity

2.4 ORDER CODE


NIVOMAG M K – 2/3 – Ex

VERSION CODE FUNCTION CODE PROCESS CONNECTION CODE ARM. LENGTH CODE
Normal A Constant hysteresis 1 92 x 92 flange 0 0 mm 0
Normal + rubber cup G Adjustable hysteresis 2 DN 80 PN 25 C steel 1 100 mm 1
Normal

Normal + silicon rubber cup S Adjustable hysteresis vertical float 3 DN 100 PN 25 C steel 2 200 mm 2
Under water U DN 125 PN 25 C steel 3 300 mm 3
Under water + rubber cup V DN 150 PN 25 C steel 4 Z or L arm 4
Under water + silicon rub. cup Z DN 80 PN 25 SS 316 Ti 5 0 mm 9
DN 100 PN 25 SS 316 Ti 6 100 mm 5
Ex version

COUNTER FLANGE DN 125 PN 25 SS 316 Ti 7 200 mm 6


NIVOMAG M F F – 1 – 0 DN 150 PN 25 SS 316 Ti 8 300 mm 7
2” BSP B Z or L arm 8
2” NPT N
MATERIAL CODE
C steel 1 MK-23
SS 316 Ti 2
TESTER ARM. LENGTH CODE
PROC. CONNECT. CODE NIVOMAG M M K – 1 0–0 1000 mm 1
Norm

2000 mm 2
92 x 92 PN 25 0
92 x 92 PN 25 for tester 1 MATERIAL CODE 3000 mm 3
1 1000 mm 5
92 x 92 PN 25 Counter fl. spec. 2 C steel
vers.

6
Ex

92 x 92 PN 25 Counter flange spec.for tester 3 SS 316 Ti 2 2000 mm


3000 mm 7

BKI 16 ATEX 0013X ♦ mka2100a0600h_10 ♦ 1/2


2.5 DIMENSIONS
LK 97 114
97 position mark
TOP

BSP 2”
NPT 2”
∅ 77
∅ 65
TOP S = 70

∅ 65
∅ 77

118
118-286

115
116

.5

116
∅ 64
123

∅ 52
20

.5
∅ 64
62.0
62.0 202 178 NPT
L=202-521 dependant on length 189 BSP
MKG 210- , MKS 210-
MKA-210-0 MKA-21B
Fixed switch differential , with protection sleeve
Fixed switch differential according to the arm length only non Ex versions Fixed switch differential, with 2″ process connection

TOP

62.0
„A, B” switchpoint dependant
„A” min: 50 MFF-111, 121 Counter flange
„B” min: 50
for MMK tester

A
C
„A+B” max = 1000 mm
„A/B” ≤ 4

.5
∅ 64
MKU-210 MKA-210-4
Fixed switch differential, for underwater application MKA-230 Adjustable switch differential, MFF-110, 120
Adjustable switch differential, vertical mounting Square counter flange
vertical mounting

97
TOP
Y1
X1

LK
Z1
Z2
116

X2

Y1
6 4.5

62.0

MKA-220_ Adjustable switch differential, vertical mounting Rectangular connection flange MMK-110, 120 Tester
1
2
3 -0 -1 -2 -3
4 MKA-220- MKA-220- MKA-220- MKA-220-
-9 Ex -5 Ex -6 Ex -7 Ex
5
Lk = 0 Lk = 100 Lk = 200 Lk = 300
6
7 L = 268 L=350 L=450 L=550
8 Diff Y1 Y2 Diff Y1 Y2 Diff Y1 Y2 Diff Y1 Y2
9 Pos. X1 X2 S (Z1) (Z2) X1 X2 S (Z2) (Z2) X1 X2 S (Z3) (Z2) X1 X2 S (Z4) (Z2)
3. INSTALLATION 1-4 +87 +20 67 131 (13) +129 +30 99 194 (19) +171 +40 131 256 (25) 213 +50 163 319 (51)
Installation according to the requested application 1-5 +87 +12 75 131 44 +129 +18 111 194 87 +171 +24 147 256 36 213 +30 183 319 45
may carry out on the basis of drawings and tables. 1-6 +87 -20 97 131 53 +129 -30 159 194 44 +171 -40 201 256 58 213 -50 263 319 72
1-7 +87 -42 129 131 84 +129 -62 191 194 92 +171 -82 253 256 121 213 -102 315 319 151
The balance of the arms with differential length is
1-8 +87 -65 152 131 123 +129 -96 225 194 142 +171 -127 298 256 187 213 -158 371 319 233
provided by the counter weight shifted to the proper 1-9 +87 -89 176 131 131 +129 -132 261 194 194 +171 -175 316 256 256 213 -218 431 319 319
point at the vertical type MKA-23_. Hysteresis 2-5 +80 +12 68 123 44 +118 +18 100 182 27 +156 +24 132 240 36 194 +30 164 299 45
switching points will be adjusted on the vertical stick 2-6 +80 -20 100 123 53 +118 -30 148 182 44 +156 -40 196 240 58 194 -50 244 299 72
with fixing rings. Function of the switch may be tested 2-7 +80 -42 122 123 84 +118 -62 180 182 92 +156 -82 238 240 121 194 -102 296 299 151
without dismantle of the instrument by the installed 2-8 +80 -65 145 123 123 +118 -96 214 182 142 +156 +127 283 240 187 194 -158 352 299 233
2-9 +80 -89 169 123 131 +118 -132 250 182 194 +156 -175 339 240 256 194 -218 402 299 319
MMK tester. Minimal length of the arm is not shorter 3-5 +47 +12 35 84 44 +70 +18 52 104 27 +93 +24 69 137 36 +116 +30 86 171 45
than 100 mm in that case. 3-6 +47 -20 67 84 53 +70 -30 100 104 44 +93 -40 133 137 58 +116 -50 66 171 72
4. ELECTRICAL CONNECTION 3-7 +47 -42 89 84 84 +70 -62 132 104 92 +93 -82 175 137 121 +116 -102 218 171 151
3-8 +47 -65 112 84 123 +70 -96 166 104 142 +93 -127 220 137 187 +116 -158 274 171 233
Ex units
3-9 +47 -83 136 84 131 +70 -132 201 104 194 +93 -175 268 137 256 +116 -218 334 171 319
4-6 +20 -20 40 53 53 +30 -30 60 78 44 +40 -40 80 103 58 +50 -50 100 128 72
Normal units 4-7 +20 -42 62 53 84 +30 -62 92 78 92 +40 -82 122 103 121 +50 -102 152 128 151
4-8 +20 -65 85 53 123 +30 -96 126 78 142 +40 -127 167 103 187 +50 -158 208 128 233
4-9 +20 -89 109 53 131 +30 -132 162 78 194 +40 -175 215 103 256 +50 -218 268 128 319
5-7 -12 -42 30 44 84 -18 -62 44 65 92 -24 -82 106 86 121 -30 -102 72 107 151
5-8 -12 -65 53 44 123 -18 -96 78 65 142 -24 -127 151 86 187 -30 -158 128 107 233
Underwater version
5-9 -12 -89 72 44 131 -18 -132 115 65 194 -24 -175 189 86 256 -30 -218 188 107 319
6-9 -20 -89 69 13 131 -30 -132 102 13 194 -40 -175 215 23 256 -50 -218 168 31 319

• 7. STORAGE CONDITIONS
2
kábeltípus: NSSHöu-J 5x1,5mm
The NIVOMAG MK float switch has to be protected against
gr.-yellow

NC overload with a ”T” marked 2.5 A circuit breaker Environmental temperature range: 25°C to +80°C Relative
brown


black

black

For Tamb > 60 °C a suitable cable shall be used.


blue

NO humidity: max. 98 %

5. SPECIAL CONDITIONS FOR SAFE USE


• Ambient and medium temperature see 2.2. 6. MAINTANCE, REPAIR
• For installation of version NIVOMAG The NIVOMAG MK-200 series devices do not require
MKU-2- Ex (with integrated maintenance on a regular basis. In some instances, however, the mka2100a0600h_11
cable) a suitable junction box shall be used. device may need a cleaning from deposited material. Repairs Jan, 2018
• The NIVOMAG MK float switch has be during or after the guarantee period are effected at the Technical specification may be changed without notice.
connected to local EP circuit. Manufacturer’s premises.