RC3000 PCM Multi-Service Multiplexer User Manual: Raisecom Technology Co., LTD
RC3000 PCM Multi-Service Multiplexer User Manual: Raisecom Technology Co., LTD
RC3000 PCM Multi-Service Multiplexer User Manual: Raisecom Technology Co., LTD
, Ltd
1. Cautions
notices.
1
Raisecom Technology Co., Ltd
Contents
1. Cautions ............................................................................................................. 1
2. Overview............................................................................................................. 7
2.1. Introduction .............................................................................................. 7
2.2. Main features: .......................................................................................... 7
3. Application examples:......................................................................................... 9
3.1. Traditional PCM application ..................................................................... 9
3.2. Automatic ADM application ...................................................................... 9
3.3. Multi devices ADM application................................................................ 10
3.4. Point-to-multipoint star topology application............................................11
3.5. Hybrid access of star topology and chain topology .................................11
4. Device type and user-board explanation .......................................................... 12
4.1. Device type explanation: ........................................................................ 12
4.2. User-board type explanation: ................................................................. 13
5. Parameters ....................................................................................................... 15
5.1. Line-board parameters: .......................................................................... 15
5.1.1. E1 interface parameters: ............................................................... 15
5.1.2. Optical fiber parameters: ............................................................... 15
5.1.3. Ethernet interface parameters:...................................................... 16
5.2. User-board parameters: ......................................................................... 16
5.2.1. Interface standard of FXS user-board (RC3000-SUB-DS): ........... 16
5.2.2. Interface standard of FXO voice relay user-board
(RC3000-SUB-DO): .......................................................................................... 17
5.2.3. Interface standard of E&M 2 audio relay user-board
(RC3000-SUB-DM2): ........................................................................................ 17
5.2.4. Interface standard of E&M 4 audio relay user-board
(RC3000-SUB-DM4): ........................................................................................ 18
5.2.5. Standard of V35 data user-board (RC3000-SUB-DV35): .............. 18
5.2.6. Interface standard of V24 data user-board (RC3000-SUB-DV24): 18
5.2.7. Interface standard of Ethernet data user-board
(RC3000-SUB-DETH):...................................................................................... 19
5.2.8. Interface standard of RS232 serial data user-board
(RC3000-SUB-D232): ....................................................................................... 19
5.2.9. Interface standard of RS422 serial data user-board
(RC3000-SUB-D422): ....................................................................................... 19
5.2.10. Interface standard of magneto telephone user-board
(RC3000-SUB-DMT):........................................................................................ 19
5.2.11. Interface standard of FXS user-board with polarity reversal function
(RC3000-SUB-DSR): ..................................................................................... 20
5.3. Power supply.......................................................................................... 20
5.4. Environment requirement....................................................................... 21
6. Structure and indicator lights............................................................................. 22
6.1. Fundamental structure: .......................................................................... 22
2
Raisecom Technology Co., Ltd
3
Raisecom Technology Co., Ltd
4
Raisecom Technology Co., Ltd
5
Raisecom Technology Co., Ltd
6
Raisecom Technology Co., Ltd
2. Overview
2.1. Introduction
RC3000 is a PCM multi-service multiplexer that uses both traditional and modern
technologies, and can provide a high reliable access at a low cost along with multi
functions, easy application and maintenance.
z Multiple up-link access methods(single E1, multi E1, optical interface and etc).
z Available to various user-boards, and supports many kinds of voice and data access,
including: Ethernet data, V35 data, V24 data and series data.
z E1 interface supports both G703 and G704 standards, and is available for PCM30
or PCM31 frame format.
z Supports multi E1 interfaces and non-blocking timeslots cross-connect of 4 E1
based on 64K, it is very convenience for point-to-multipoint access application and
can save both devices and money for our costumers.
z Use large integrated circuit module and programmable logic circuit, and there are
multi kinds of check methods in control program to make sure of stable work.
z Supports hot swap, the user configuration will not be changed and is easy to
maintain.
z Auto recognization and configuration of user-board, for simple application the device
can start to work without any configuration.
z Master/slave clock mode supports clock holding, locking and free running to easy
your work and reduce wrong operations.
z Easy configuration of E1 mode and line signal enables flexible access with other E1
interfaces of different factories.
z Supports hyper terminal configuration, and is very convenience for maintenance
and fault detection.
z Supports field upgrade in local and remote network management upgrade
z Save data in EEPROM and check the data by many methods to avoid data loss or
destroyment.
7
Raisecom Technology Co., Ltd
8
Raisecom Technology Co., Ltd
3. Application examples:
Figure 1
The default factory status of RC3000 is without any configuration. All user-boards
support automatic recognition and voice channel allocation. In figure 1, the same
extension slots in the two devices use the same timeslots. In simple application, with
proper user-board the devices can start to work without any configuration. In this case
RC3000 does not use its function of cross connect and add/drop voice channel, this is
same as traditional single E1 PCM30 device that for point-to-point connection.
RC3000-2E1, RC3000-2E1 (ADM), RC3000-4E1, RC3000-OPT all can be used in this
way.
RC3000-2E1 (ADM) has the ADM function, and figure 2 is a typical application:
9
Raisecom Technology Co., Ltd
RC3000-2E1 (ADM) will connect the same channels (unused) of 1E1 and 2E1
automatically. That is to say, when there is no user-board all the channels in 1E1 will be
cross connected with those of 2E1; in this case the device has ADM function. The
relationship of the two devices is in figure 3:
Device 2 Sub-card 2
Device 3 Sub-card 3
Figure 3
The user-boards in local and those in remote are corresponding to each other, and the
local device can allot service to the three remote ones. Meanwhile work status of middle
device will not affect the last device.
When you need complicated ADM or multi services you can configure the device
yourself, and the number of connected RC3000 is alterable.
Remote
Local
Transmission
Transmission
network
network
N *RC3000
Figure 4
10
Raisecom Technology Co., Ltd
In this application, voice channels in local device can be alloted to remote RC3000s, and
voice channels of remote RC3000s can be cross connected too. So multi services
access can be realized.
Remote
Local
Transmission
network
Figure 5
This application can reduce the number of devices for multi user service configuration.
Remote
Local
Transmission
network
Transmission
network
Transmiss
ion
Figure 6
11
Raisecom Technology Co., Ltd
12
Raisecom Technology Co., Ltd
User-boards of RC3000:
User-board type User-board name Channel description
RC3000-SUB-DS FXS user voice user-board 8 channels, unconfigurable
RC3000-SUB-DO FXO voice relay user-board 8 channels, unconfigurable
RC3000-SUB-DSO FXS and FXO hybrid voice 8 channels, unconfigurable
user-board
RC3000-SUB-DM2 E&M 2 audio relay user-board 8 channels, unconfigurable
RC3000-SUB-DM4 E&M 4 audio relay user-board 4 channels, unconfigurable
RC3000-SUB-DV35 V35 data user-board 1 interface, and the time
slots of channel is
configurable
RC3000-SUB-DV24 V24 data user-board 1 interface, and the time
slots of channel is
configurable
RC3000-SUB-DETH 10BaseT Ethernet data 1 interface, and the time
user-board slots of channel is
configurable
RC3000-SUB-D232 RS232 serial data user-board 8 channels, unconfigurable
13
Raisecom Technology Co., Ltd
14
Raisecom Technology Co., Ltd
5. Parameters
15
Raisecom Technology Co., Ltd
RJ-45 interface of UTP, the longest tansmission distance of 5-category cable is 100m.
Comply with IEEE 802.3, 10/100M auto negotiation, full/half duplex auto negotiation.
Support IEEE 802.1d Spanning Tree relay, IEEE 802.1q VLAN packet relay
Maximum Ethernet frame size is 1916 byte
Support flow control of IEEE 802.3x in full duplex
Support flow contrla of backpressure in half duplex
MDI and MDIX auto sensing
16
Raisecom Technology Co., Ltd
(RC3000-SUB-DO):
(RC3000-SUB-DM2):
AD gain: 0 db
DA gain: -3.5 db
AD frequency characteristic (300-3400Hz): 0±0.2 db
DA frequency characteristic (300-3400Hz): 0±0.2 db
Output loop impedance: 600Ω
Input loop impedance: 600Ω
Blance: 60-70 db
17
Raisecom Technology Co., Ltd
Return loss: 20 db
Maximum voltage of common-mode: 300 V
Common-Mode Rejection Ratio: >55 db
Power supply Rejection Ratio: 30 db
Idle channel noise: 60 db
Note: AD gain and DA gain are adjustable according to user’s requirement
(RC3000-SUB-DM4):
AD gain: +14 db
DA gain: +4 db
AD frequency characteristic (300-3400Hz): 0±0.2 db
DA frequency characteristic (300-3400Hz): 0±0.2 db
Output loop impedance: 600Ω
Input loop impedance: 600Ω
Blance: 60 db
Maximum voltage of common-mode: 300 V
Common-Mode Rejection Ratio: >60 db
Power supply Rejection Ratio: 30 db
Idle channel noise: >60 db
Note: AD gain and DA gain are adjustable according to user’s requirement
18
Raisecom Technology Co., Ltd
(RC3000-SUB-DETH):
RJ-45 interface of UTP, the longest tansmission distance of 5-category cable is 100m.
Comply with IEEE 802.3 standard, 10/100M auto negotiation, full/half duplex auto
negotiation.
Support IEEE 802.1d Spanning Tree relay, IEEE 802.1q VLAN packet relay
Maximum Ethernet frame size is 1916 byte
Support flow control of IEEE 802.3x in full duplex
Support flow contrla of backpressure in half duplex
MDI and MDIX auto sensing
(RC3000-SUB-D232):
(RC3000-SUB-D422):
(RC3000-SUB-DMT):
19
Raisecom Technology Co., Ltd
function (RC3000-SUB-DSR):
20
Raisecom Technology Co., Ltd
Temperature:0 ~ 50℃
Relative humidity:≤90%(25℃ noncondensing)
21
Raisecom Technology Co., Ltd
System NM channel
information & MPU control module
alarm
Memory module
RC7850 module
Line-board User-board
Cross-matrix and
interface interface
information processing
module module
module
Figure 15
RC3000 can multiplex or demultiplex local voice channels or data to any time slots (time
slot 0 is not included) of RC7850’s 4 E1 through cross-matrix, the following is exact
explanations:
Line-board interface module: interface of up-link data channel, E1 or optical interface.
User-board interface module: user interface for data or voice access.
RC7850 module: cross connect the user information to up-link interface or up-link data
to user interface through cross-matrix.
Memory module: save all kinds of user configuration including work status and cross
information.
Network management channel: a management channel for PC.
System information & alarm information display module: provide our users present
system status and alarm information; meanwhile the buzzer will buzz so that user can
22
Raisecom Technology Co., Ltd
Management CONSOLE
Alarm and system indicator
lights
Center
multiplexer
Fan
中心复
接单元
板
23
Raisecom Technology Co., Ltd
Front view:
Figure 17
SYS(green): Indicates system work status. Flicking: system works normal. ON: 1 CUP
works abnormal; 2 system configuration error or the following problems:
1.User-board communicates abnormally
2.Temperature sensor works abnormally
3.Fan does not work
4.Time slots configuration error
OFF: CPU works abnormally
PWR(green): OFF system is not powered on
TX(green): ON serial interface is transmitting data
RX(green): ON serial interface is receiving data
Optical interface alarm indicator lights form a matrix, L and R indicate local and remote,
OP(LOS,LOF , E-3, E-6)indicate alarms:
L OP LOS(red): Loss of signal at local
L OP LOF(red): Loss of frame at local
L E1 E-3(red): Alarm when bit error ratio is more than 10-3/s at local
L E1 E-6(red): Alarm when bit error ratio is more than 10-6/s at local
R OP LOS(red): Loss of signal at remote
R OP LOF(red): Loss of frame at remote
24
Raisecom Technology Co., Ltd
R E1 E-3(red): Alarm when bit error ratio is more than 10-3/s at remote
R E1 E-6(red): Alarm when bit error ratio is more than 10-6/s at remote
These indicator lights form a matrix, 1, 2, 3, 4 indicate 4 E1 line, USED, LOS, LOF, AIS,
CRC, RAL indicate the using status of the 4 E1 and alarms:
USED(green): ON this E1 line is used; OFF this E1 line is unused
LOS(red): ON loss of E1 signal
LOF(red): ON loss of E1 frame
AIS(red): ON there is E1 AIS alarm
CRC(red): ON there is E1 CRC error
RAL(red): ON there is alarm in remote E1 line
Note: if E1 interface is not used, there no corresponding alarms.
MUTE:
A lockless button to mute alarm sound. There will be alarm sound if there are alarms.
This button only mutes the present sound. And if there are new alarms there will be new
alarm sound.
CONSOLE:
A RJ45 connector to connect PC and RC3000 device for Hyper Terminal configuration
(through the cable offered by Raisecom, and please plug the cable in RJ45 connector
first and then the DB9 serial interface connector on PC, this will protect the serial
interface), set the first bit of DIP-switches ON, startup Hyper Terminal and then you can
configure the device.
LINK:
There are two RJ45 connectors for network management: UP and DOWN.
UP (RJ45 connector): network management interface for PC, through this interface a PC
can manage all the RC3000 devices in this network (the second bit of DIP-switches
should be ON).
DOWN(RJ45 connector): This is a cascade interface for RC3000 or other devices need
to be managed.
DIP-switches:
First bit: CONSOLE configuration. Set this bit ON, connect RC3000 with PC through
serial interface cable offered by Raisecom, and then you can configure the device by
25
Raisecom Technology Co., Ltd
Hyper Terminal. This operation will not affect the whole network management but only
shielded that device for a while.
Second bit: PC network management access. When this RC3000 is network
management access device or network management is connected to its LINK UP
interface, set this bit ON, and MCU will receive the network management information
from LINK UP interface.
Third bit: assistant network management channel shielded bit. When the device
connected with the E1 interface is not a RC3000 device, the assistant network
management channel may not work. And to make sure of normal network management,
set this bit ON, shield assistant channel and than manage the device, in this case LINK
DOWN interface is still available for cascade.
The last bit is reserved.
Note: in a physical network of RC3000s only one network management PC is available,
or you cannot manage the devices normally.
Rear view:
There are 3 extension slots for user-board, from left to right: SLOT1, SLOT2 and SLOT3.
When channel number of a user-board is not configurable, this number will be equal or
less than 8. In this case, channels for each slot are:
SLOT1: 1-8 channels
SLOT2: 9-16 channels
SLOT3: 17-24 channels
When channel number of a user-board is configurable, RC3000 will distribute channels
for each slot:
SLOT1: 1-8 channels of main channel
SLOT2: 9-16 channels main channel
SLOT3: 17-30 channels (PCM30) or 17-31 channels(PCM31)main
channel
Note: time slot configuration is available in the following chapters.
26
Raisecom Technology Co., Ltd
All user-boards support hot-swap and this operation will not affect device work status.
There is one line-board slot for each RC3000 and the device cannot work without
line-board. You must confirm the type of line-board when ordering because it is fixed and
not hot-swap:
1. Optical line-board + 100M Ethernet interface: RC3000-OPT-FE
2. Optical line-board + 2E1 interfaces: RC3000-OPT-2E1
3. Line-board with unbalanced 2 E1 interfaces: RC3000-2E1
4. Line-board with balanced 2 E1 interfaces: RC3000-2E1-BL
5. Line-board with 4 E1 interfaces: RC3000-4E1
There are two kinds of power supply interface for AC and DC, voltage range is: AC
85V ~ 265V, DC –36V ~ -72V.
Note: please make sure of grounding protection when using AC power supply for safty.
27
Raisecom Technology Co., Ltd
There is only hardware version of a new RC3000 and without any cross configuration.
RC3000 will check all configurations when powered on, including: system configuration
information, cross connect configuration information, line-board information and
user-board information. Meanwhile all LEDs will flick and buzzer will buzz, otherwise
there is error of some parts of device.
28
Raisecom Technology Co., Ltd
In factory default status, clock mode of RC3000 is slave clock (trace first E1); the device
can switch clock by itself in clock auto-switch mode according to practice so that all
devices can work under a uniform clock. You can also set the work clock manually. Once
powered on RC3000 will first synchronize with configured clock. If this clock is invalid, in
auto clock mode RC3000 will switch the clock according to work status and in manual
clock mode, it will keep history configuration.
Suggestion: please be attention to clock mode when organize your network with lots of
RC3000s and make sure of uniform clock.
In factory default status, RC3000 can cross connect user-board channels with first user
E1. For simple application RC3000 can work normally without any configuration. Details
are as follows: User-board in first slot:
If the channel number of the user-board is not configurable, system will cross connect
user-board’s channels with those of first user E1 channels 1-8 one by one according to
user-board channel number (note: this number should be equal or less than 8); if the
user-board channel number is configurable, system will give it 8 channels and cross
connect the 8 channels with first user E1 channels 1-8.
User-board in second slot:
If the channel number of the user-board is not configurable, system will cross connect
user-board’s channels with those of first user E1 channels 9-16 one by one according to
user-board channel number (note: this number should be equal or less than 8); if the
user-board channel number is configurable, system will give it 8 channels and cross
connect the 8 channels with first user E1 channels 9-16.
User-board in third slot:
If the channel number of the user-board is not configurable, system will cross connect
user-board’s channels with those of first user E1 channels 17-24 one by one according to
user-board channel number (note: this number should be equal or less than 8); if the
user-board channel number is configurable, system will give it 14 channels and cross
connect the 14 channels with first user E1 channels 17-30.
RC3000 does not cross connect idle channels except RC3000-2E1 (ADM). RC3000-2E1
(ADM) cross connect the same idle channels of 1 E1 and 2 E1 to realize the transfer of
29
Raisecom Technology Co., Ltd
configuration
RC3000 has rich configuration information for any E1 interface and signal interface to
realize all kinds of cross connect. Please refer to appendix A. how to use Hyper Terminal
to configure RC3000.
There are two kinds of alarms: 1 device alarms; 2 system alarms. Device alarms indicate
E1 line and optical interface alarms, and optical interface alarms includes:
a. LOS alarm at local
b. LOF alarm at local
c. Alarm when bit error ratio is more than 10-3/s at local
d. Alarm when bit error ratio is more than 10-6/s at local
e. LOS alarm at remote
f. LOF alarm at remote
g. Alarm when bit error ratio is more than 10-3/s at remote
h. Alarm when bit error ratio is more than 10-6/s at remote
E1 interface alarms:
a. LOS alarm
b. LOF alarm
c. AIS alarm
d. CRC error alarm
30
Raisecom Technology Co., Ltd
1E1
2E1
1E1 1E1 3E1 1E1
A D F
2E1 4E1
1E1 1E1
B E
Figure 19
31
Raisecom Technology Co., Ltd
In this topology the lines between each RC3000 are assistant network management
channels, and for normal network management there must be network management
topology configuration as follows:
RC3000 A: double E1 channel direction RC3000 B: single E1 channel direction
RC3000 C: single E1 channel direction RC3000 D: four E1 channel direction
RC3000 E: single E1 channel direction RC3000 F: single E1 channel direction
Rules for network management topology: the number of network management channels
decides the number of E1 direction, and configuration of E1 direction must start from 1
E1.
b. Network management cascade:
Local and remote network management channel connection can be realized through
LINK UP and LINK DOWN interfaces on RC3000 as in figure 20:
LINK LINK
1E1 1E1 DOWN UP
B E
A
LINK 1E1
DOWN
LINK
UP 1E1
1E1 1E1
D
C F
Figure 20
There are three RC3000 networks: RC3000 A and RC3000 B connected through E1
cable, RC3000 C and RC3000 D connected through E1 cable, RC3000 E and RC3000 F
connected through E1 cable; connect RC3000A and RC3000C through cascade cable,
RC3000B and RC3000E through cascade cable, and set the second bits of A, C, E’s
DIP-switches ON, then local and remote network management channel connection can
be realized through LINK UP and LINK DOWN interfaces
32
Raisecom Technology Co., Ltd
12 3 4 5 6 7 8
Pin number Signal Explanation
3 RXD Rx of RC3000
7 TXD Tx of RC3000
4,8 GND Ground of RC3000
Figure 21
b.LINK UP definition:
Network management interface LINK UP is RC45 interface and standard RC232 voltage:
Signaling and Pinouts:
Pin number Signal Explanation
3 RXD Rx of RC3000
7 TXD Tx of RC3000
4,8 GND Ground of RC3000
33
Raisecom Technology Co., Ltd
FXS is a user voice card with feed voltage and feed ring and can be connected to
exterior line interface of FBX. There are 8 channels of a FXS and the channel number is
decided by hardware, unchangeable. Two RJ45 interfaces make up of the 8 channels
(each RJ45 interface has four channnels). Definition of RJ45 interface is as follows:
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
RJ45-1 RJ45-2
Figure 22
Channel 1 2 3 4
Pins RJ45-1 1A,2B RJ45-1 3A,4B RJ45-1 5A,6B RJ45-1 7A,8B
Channel 5 6 7 8
Pins RJ45-2 1A,2B RJ45-2 3A,4B RJ45-2 5A,6B RJ45-2 7A,8B
Bus
Voice channel control inteface
module Multiplexing
Voice Voice input & module
channel Int 2W & 4W balance output Multiplexi
interface erf module ng bus
ac Signal input Multiplexing
e & output bus module
pr
Voice D/A
ot
converter Control of
ec
channel Control bus Control
tio
output module bus
n
Detect of ring and
pickup/hangup
Figure 23
34
Raisecom Technology Co., Ltd
FXO is a voice relay card for the relay of FBX voice channel and is connected to output
interface of FBX voice channel. There are 8 channels of a FXO and the channel number
is decided by hardware, unchangeable. Two RJ45 interfaces make up of the 8 channels
(each RJ45 interface has four channnels). Definition of RJ45 interface is as follows:
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
RJ45-1 RJ45-2
Figure 24
Channel 1 2 3 4
Pines RJ45-1 1A,2B RJ45-1 3A,4B RJ45-1 5A,6B RJ45-1 7A,8B
Channel 5 6 7 8
Pins RJ45-2 1A,2B RJ45-2 3A,4B RJ45-2 5A,6B RJ45-2 7A,8B
Bus
Voice channel control interface
module Multiplexing
Voice Voice input & module
channel Int 2W & 4W balance out put Multiplex
interface erf module ing bus
ac Signal input Multiplexing
e & out put bus module
pr Voice D/A
ot converter Control of
ec channel Control bus Control
tio output module bus
n
Detect of loop and
ring
Figure 25
35
Raisecom Technology Co., Ltd
RC3000-SUB-DSO is a customized hybrid card of FXS and FXO, there can be N FXS
interfaces and M FSO interfaces (M, N can be 0, and M+N=8). There totally 8 channels
decided by hardware, unchangeable. Two RJ45 interfaces make up of the 8 channels
(each RJ45 interface has four channnels). Definition of RJ45 interface is as follows:
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
RJ45-1 RJ45-2
Figure 26
Channel 1 2 3 4
Pins RJ45-1 1A,2B RJ45-1 3A,4B RJ45-1 5A,6B RJ45-1 7A,8B
Channel 5 6 7 8
Pins RJ45-2 1A,2B RJ45-2 3A,4B RJ45-2 5A,6B RJ45-2 7A,8B
RC3000-SUB-DM2 is a 2W audio relay card with E&M signal, used for transmission of
signal and voice between offices. There totally 8 channels decided by hardware,
unchangeable. Two RJ45 interfaces make up of the 8 channels (each RJ45 interface has
four channnels). Definition of RJ45 interface is as follows:
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Figure 27
Channel 1 2 3 4
Pins RJ45-1 RJ45-1 RJ45-2 RJ45-2
1A, 2B, 3E, 4M 5A, 6B, 7E, 8M 1A, 2B, 3E, 4M 5A, 6B, 7E, 8M
Channel 5 6 7 8
Pins RJ45-3 RJ45-3 RJ45-4 RJ45-4
1A, 2B, 3E, 4M 5A, 6B, 7E, 8M 1A, 2B, 3E, 4M 5A, 6B, 7E, 8M
Note: A and B is 2-wire channel voice, E is E signal Rx and M is M signal Tx.
36
Raisecom Technology Co., Ltd
Bus
Voice channel control module interface
Multiplexing module
Voice channel Voice input &
interface 2W & 4W balance output Multiplexing
module bus
Signal input & Multiplexing bus
output process module
Voice D/A converter
Control of
channel output Control bus process Control bus
module
E & M signal process
module
Figure 28
RC3000-SUB-DM2 is a 4W audio relay card with E&M signal, used for signal and voice
transmission between offices. There totally 8 channels decided by hardware,
unchangeable. Two RJ45 interfaces make up of the 8 channels (each RJ45 interface has
four channnels). Definition of RJ45 interface is as follows:
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Figure 29
Channel 1 2 3 4
RJ45-1 RJ45-2 RJ45-3 RJ45-4
1TA, 2TB 1TA, 2TB 1TA, 2TB 1TA, 2TB
Pins
3RA, 4RB 3RA, 4RB 3RA, 4RB 3RA, 4RB
6E, 7M 6E, 7M 6E, 7M 6E, 7M
Note: 1TA and 2TB is 2-wire voice Tx, 3RA and 4RB is 2-wire voice Rx, 6E is E signal Rx
and 7M is M signal Tx.
37
Raisecom Technology Co., Ltd
Bus
Voice channel control module interface
Multiplexing module
Voice channel
Voice input &
interface Multiplexing
output
Voice D/A converter
bus
Signal input & Multiplexing bus
output process module
Control of
channel output Control bus process Control bus
E & M signal process
module
module
Figure 30
RC3000-SUB-DV35 is a data user-board with V35 interface and the channel number is
configurable, the rules are as follow:
a. Rules for automatic channel distribution: RC3000 has automatic channel
distribution function. If V35 data is put into the first slot and 1-8 channels of
the first user E1 are idle, system will distribute 1-8 channels of the first user
E1 to it; If V35 data is put into the second slot and 9-16 channels of the
second user E1 are idle, system will distribute 9-16 channels of the first user
E1 to it; If V35 data is put into the third slot and 17-30 channels of the first
user E1 are idle, system will distribute 17-30 channels of the first user E1 to it
(or 17-31 in PCM31 frame mode)
b. Rules for manual channel distribution:
There will be position limitation for manual channel distribution. Here we will
first give the definition of cross connect groups. RC3000 can have 4 E1 at
most and we use 1, 2, 3, and 4 to stand them (each E1 is one cross group,
and now we have cross group 1, 2, 3, and 4), it also has four STBUSes (2M
38
Raisecom Technology Co., Ltd
of each) to access 4 user groups (user E1), and we refer these 4 user E1 as
cross groups 5, 6, 7 and 8.
The first user E1 is a main cross group and channels of this cross group will
be distributed to user cards by default. Other user E1s are single cross group
for different slots: user card in first slot will occupy cross group 6 (user E1 2)
and user card in second slot will occupy cross group 8 (user E1 4), user card
in the third slot cannot have single cross group.
Limitation for main cross group (user E1 1): when use main cross group to
transfer data the number of channels will not same for different slots. Channel
number range for first slot is 0-31, 0 indicates that shutdown the transmission
of this user card, and the startup channel is channel 1. If other slots have
already occupied the channels of main cross group there will alarms.
Channel number range for second slot is 0-23, 0 indicates that shutdown the
transmission of this user card, and the startup channel is channel 9. If other
slots have already occupied the channels of main cross group there will
alarms. Channel number range for the third slot is 0-15, 0 indicates that
shutdown the transmission of this user card, and the startup channel is
channel 17.
Limitation for single cross group: Channel number range is 0-31; the startup
channel is channel 1 and there will not be channel occupation collision
alarms.
Point-to-point communication can be realized by automatic channel distribution, and
we recommend you list the cross connect table first to avoic mistakes.
V35 interface uses V35/HDB26 female connector and can be connected to standard
DTE cable as in following figure:
Figure 31
39
Raisecom Technology Co., Ltd
V35 user-board has many functions: plenty test methods, loop, phase adjustment and
etc. Both Hyper Terminal and network management can configure the following
commands:
40
Raisecom Technology Co., Ltd
Ethernet interface uses RJ45 connector and can realize MDI & MDIX cable as following
figure:
Figure 32
Ethernet user card has many functions and both Hyper Terminal and network
management can configure the following commands:
a. Configuration of user card time slot; b. Choose the data channel; c.
Buffer configuration
d. Default interface mode e. Interface reset
Please refer to Appendix A How to use Hyper Terminal to configure RC3000
RC3000-SUB-D232 serail data user-board has standard RS232 interface. There are 8
channels whitch is decided by hardware, unchangeable. Four RC45 connectors make up
of the 8 channels and each RJ45 connector has two channels. And the definition of each
41
Raisecom Technology Co., Ltd
interface is as follows:
Channel 1 2 3 4
RJ45-1 RJ45-1 RJ45-2 RJ45-2
Pins
2RD,3TD,1,4GND 6RD,7TD,5,8GND 2RD,3TD,1,4GND 6RD,7TD,5,8GND
Channel 5 6 7 8
RJ45-3 RJ45-3 RJ45-4 RJ45-4
Pins
2RD,3TD,1,4GND 6RD,7TD,5,8GND 2RD,3TD,1,4GND 6RD,7TD,5,8GND
Note: 2RD is the input of RS232 Rx data, 3TD is the output of Tx data and 4GND is the
ground. Here we want to explain the grounding rules: there are two grouding conductors,
one is signal grounding and the other one is chassis grounding. Please connect the
RJ45 connector of RS232 first and then DB interface of other device when connect
RS232 with other device (both powered on), this can make sure of grouding protection to
avoid destroyment of RS232 serial interface.
RC3000-SUB-D422 user card has standard serial data interface. There are 8 channels
whitch is decided by hardware, unchangeable. Four RC45 connectors make up of the 8
channels and each RJ45 connector has two channels. And the definition of each
interface is as follows:
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Figure 34
Channel 1 2 3 4
RJ45-1 RJ45-1 RJ45-2 RJ45-2
Pins
1RA,2RB,3TA,4TB 5RA,6RB,7TA,8TB 1RA,2RB,3TA,4TB 5RA,6RB,7TA,8TB
Channel 5 6 7 8
RJ45-3 RJ45-3 RJ45-4 RJ45-4
Pins
1RA,2RB,3TA,4TB 5RA,6RB,7TA,8TB 1RA,2RB,3TA,4TB 5RA,6RB,7TA,8TB
Note: 1RA is the positive input of RS422 Rx data, 2RB is the negative input of RS422 Rx
data, 3TA is the the positive output of RS422 Tx data and 4TB is the negative output of
RS422 Tx data. RC3000-SUB-D422 user card has static protection and the serial
interface will not be destroyed. In application, please connect the cable first and then
plug the user card into RC3000 slot.
42
Raisecom Technology Co., Ltd
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
RJ45-1 RJ45-2
Figure 35
Channel 1 2 3 4
Pins RJ45-1 1A,2B RJ45-1 3A,4B RJ45-1 5A,6B RJ45-1 7A,8B
Channel 5 6 7 8
Pins RJ45-2 1A,2B RJ45-2 3A,4B RJ45-2 5A,6B RJ45-2 7A,8B
Bus
Voice channel control interfaces
module Multiplexing module
Voice Voice input &
channel Int 2W & 4W balance output Multiplexi
interface erf module ng bus
ace Signal input & Multiplexing bus
pro output process module
tec
Voice D/A converter
tio
Control of
n
channel output Control bus Control
process module bus
Ring output & detect
Figure 36
43
Raisecom Technology Co., Ltd
RC3000-SUB-DSR is a phone interface card with polarity reversal function. There are 8
channels which are decided by hardware, unchangeable. Two RC45 connectors make
up of the 8 channels and each RJ45 connector has four channels. And the definition of
each interface is as follows:
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
RJ45-1 RJ45-2
Figure 37
Channel 1 2 3 4
Pins RJ45-1 1A,2B RJ45-1 3A,4B RJ45-1 5A,6B RJ45-1 7A,8B
Channel 5 6 7 8
Pins RJ45-2 1A,2B RJ45-2 3A,4B RJ45-2 5A,6B RJ45-2 7A,8B
Bus
Voice channel control inteface
module Multiplexing
Voice
Voice input & module
channel
Int 2W & 4W balance output Multiplexi
interface
erf module ng bus
ac Signal input Multiplexing
e & output bus module
pr Voice D/A
converter Control of
ot
channel Control bus Control
ec
output module bus
tio Polarity reversal,
Detect of ring and
pickup/hangup
Figure 38
44
Raisecom Technology Co., Ltd
Optical line-board can communicate with main board and its initial value can be set
through DIP switches. There are 2 banks of 8-bit DIP switches and definitions ard as
follows:
Switch Definition Value Explanation
FFFF S1
FFFN S2
FFNF S3
FFNN SS13
Optical
FNFF SS15
1-4 module
FNFN SS23
type
FNNF SS25
FNNN S1FC
NFFF M
Other Other status will be regarded as S1 (0000)
F Without ALS function
SW1 5 ALS
N With ALS function
Auto F Enable auto negotiation function
6
negotiation N Disable auto negotiation function
Ethernet port rate is 100M (auto negotiation
F
disable)
7 100M/10M
Ethernet port rate is 10M (auto negotiation
N
disable)
Ethernet port works in full duplex mode (auto
F
Full/half negotiation disable)
8
duplex Ethernet port works in half duplex mode (auto
N
negotiation disable)
1-4E1 F Relative E1 line works normally
1-4
Loop back N Relative E1 line is doing the loop back test
SW2 Loop back F Local loop back
5
type N Remote loop back
6-8 Reserved Reserved
Note: F stands for OFF and N stands for ON status. Network management has higher
privilege than DIP switches except optical module type and ALS function configuration.
All configuration information is available through Hyper Terminal. First bit to fifth bit of
SW1 are set in factory according to optical module type and other bits are all OFF.
Optical line-board can communicate with main board and its initial value can be set
45
Raisecom Technology Co., Ltd
through DIP switches. There are 3 banks of 8-bit DIP switches and definitions ard as
follows:
46
Raisecom Technology Co., Ltd
Check whether the type of device, spare parts and number are same with that of packing
list. Make sure the device appearance is in excellent condition. There must be drying
process if the device has been damp.
8.3. Installation
RC3000 can be installed in the chassis or on cabinet. Please make sure that the
installation is firm and convenience for operation.
47
Raisecom Technology Co., Ltd
offered, and when you need to transfer balanced interfaces to unbalanced ones
RC909-4E1 of Raisecom is available.
c. Optical interface:
SC connector is for optical interface. And if you are not sure of Rx & Tx direction,
please connect the connector before device powered on.
d. Connect network management interface:
When this device is connected with network management PC, connect cable to
LINK UP interface; and when you need network management cascade, connect
cable to LINK DOWN interface. Please connect to network management interface
before device powered on if you are not sure of common grounding.
a. Verify all the connections are normal (power supply and interfaces), and than
powered on.
b. Verify the self-check of the device is normal (PWR is ON and SYS is flicking).
Buzzer will buzz if there are alarms and MUTE botton can shutdown present
alarm sound.
c. You do not need to configure the device for point-to-point topology. Use
CONSOLE interface to configure the device when necessiry.
d. RC3000 will work normally if all connections are right.
48
Raisecom Technology Co., Ltd
9. Q & A
9.1. SYS is ON
When there are alarms SYS will be ON. You can check the alarm information through
network management or Hyper Terminal to confirm why the buzzer buzzes:
a. Communication failure with user card.
b. Communication failure with line-board when line-board is RC3000-OPT.
c. Collision of channel occupation.
d. Fan problems.
e. Temperature collection problems
If these are not the reasons why buzzer buzzes, please contact us for technical support.
If there are LOF, LOS or AIS alarms, please check the followings:
a. Cable of E1 or optical interface has been correctly connected.
b. Device connected to RC3000 works normally.
c. If E1 is not used, please shut it down.
d. Verify the impedance of both ends match each other, or change the
impedance.
e. Verify grounding protection.
If these are not the reasons, please contact us for technical support.
49
Raisecom Technology Co., Ltd
communication is abnormal
If not all devices in a network can be managed, please check the followings:
a. Check the cables connected to all devices first.
b. Check the network topology.
c. Check the DIP-switches of device that cannot be managed, remember to
set first bit (CONSOLE control bit) OFF.
d. Check the network management configuration, make sure that time slot for
network management of all devices is the same (occupy time slot 0 or 1)
and number of network management channels is same with that of E1
direction.
e. When manage two RC3000-OPT devices, the network management
topology should be single E1 direction, otherwise you may not manage the
remote device
f. Check the configuration of device ID and Baud rate, in a RC3000 network
all devices must have different ID and same baud rate, and when assistant
network management channel is used, the Baud rate must be 2400Bps.
50
Raisecom Technology Co., Ltd
If these are not the reasons why you cannot manage the device, please contact us for
technical support.
If the device cannot be configured through CONSOLE, please check the followings:
a. Check that proper cable is used to connect to CONSOLE.
b. Check the configuration of Hyper Terminal (refer to appendix A: How to user
Hyper Terminal)
c. Check the DIP-switches and set the Console control bit ON (the second bit).
d. In Hyper Terminal press M to display the menu if ENTER is not effective.
e. When you press the ENTER, light of serial interface Tx will lighten and this
indicates that RC3000 receives data normally. Otherwise check other
configuration.
f. Check serial interface
If these are not the reasons why you cannot configure the device, please contact us for
technical support.
If the information saved in memory lost after RC3000 running for some time, check
whether EEPROM can save data normally, if not, bring the device back to Raisecom for
maintenance.
When forget your password, you must bring the device back to Raisecom for password
updating.
51
Raisecom Technology Co., Ltd
configure RC3000
10.1. Enter
Use the affixed CONSOLE cable to connect CONSOLE interface (RJ45) of RC3000 with
PC serial interface (DB9), before connecting make sure that both RC3000 and PC have
grounding protection; and you should connect the cable to CONSOLE interface of
RC3000 first and then the PC serial interface. Set the first bit of DIP-switches ON, start
Hyper Terminal program and configure COM interface as figure 37:
Figure 39
52
Raisecom Technology Co., Ltd
Figure 40
Before starting to configure the device you need to input the password (default password
is raisecom), the prompt is:
Please input password and click Enter
Password:
When enter the password there will be a * for every input character. If you want to
change the password: use BackSpace key for wrong enters; password is case sensitive,
and control character is invalid. After setting the new password enter the new one again
to comfirm. And then you can configure the device.
If the password is wrong there will be the prompt:
Input password error or input illegal charactor.
Please input password again
Password:
53
Raisecom Technology Co., Ltd
In main menu press number key 1, and then there will be device set query menu:
1.Device ID and Baud rate
2.Line-Board info(RAM)
3.Line-Board info(EEPROM)
4.E1 using and mode info
5.Clock,CRC and Net info
6.E1 Alarm Mask info
7.User-Board info(RAM)
8.User-Board info(EEPROM)
In device set query menu press number key 1, and there will be device ID and baud rate
information:
Device ID:1 Baud Rate:2(2400bps)
54
Raisecom Technology Co., Ltd
In device set query menu press number key 2, and then there will be device Line-Board
information:
Real information:
Line-Board Type:2E1 Board (Line-Board card name)
2E1 Line-Board:
Line-Board Type:2E1 Board
4E1 Line-Board:
Line-Board Type:4E1 Board
In device set query menu press number key 3, and then there will be device Line-Board
information:
EEPROM Set:
Line-Board Type:2E1 Board
55
Raisecom Technology Co., Ltd
Indevice set query menu press number key 4, and there will be E1 using and mode
information:
E1: First Second Third Fourth
Real information:
Use: 1=Using 1 1 0 0
Mode: 1=PCM31 0 0 0 0
Mask: 1=Mask 0 0 0 0
EEPROM Set:
Use:1=Using 1 1 0 0
Mode:1=PCM31 0 0 0 0
Mask:1=Mask 0 0 0 0
Indevice set query menu press number key 5, and there will be E1 using and mode
information:
Real information:
Clock Mode: Recovered Clock(1 E1) Auto
Net Topology: Single E1 Direction
Net Using Time Slot: 0 Time Slot
CRC Transmit: Enable
Alarm Sound Output: Disable
EEPROM information:
Clock Mode: Recovered Clock(1 E1) Auto
Net Topology: Single E1 Direction
Net Using Time Slot: 0 Time Slot
CRC Transmit: Enable
Alarm Sound Output: Disable
56
Raisecom Technology Co., Ltd
Indevice set query menu press number key 6, and there will be E1 Alarm Mask
information:
Alarm LOS AIS LOF RAL LOMF LOMFC CRC
Real information:
1st E1 1=Mask 0 0 0 0 0 0 0
2nd E1 1=Mask 0 0 0 0 0 0 0
3rd E1 1=Mask 0 0 0 0 0 0 0
4th E1 1=Mask 0 0 0 0 0 0 0
EEPROM Set:
1st E1 1=Mask 0 0 0 0 0 0 0
2nd E1 1=Mask 0 0 0 0 0 0 0
3rd E1 1=Mask 0 0 0 0 0 0 0
4th E1 1=Mask 0 0 0 0 0 0 0
Indevice set query menu press number key 7, there will be the prompt:
Input User Board No.(1-3, Esc=Cancel):
Then chose the user-board number you want to query and there will be the user-board
interformtion:
User-Board X:
Type: user-card name Channel Number: X Set Mode:
Hardware/Software
Device Query Command:1-8, Menu Display:M, Return:Q Command:
User-board type 6 V35 data user card information:
Type: 6 V35 User Board Channel Number: 7 Set Mode:Software
Signal:None Receive Phase:Positive Transmit
Phase:Positive
57
Raisecom Technology Co., Ltd
Channel:Main Channel
Local Loopback:Loopback Remote Loopback:No Loopback
Error Code Test:Disable
7235 Auto Adjust Phase:Enable
Adjust Receive Phase:Enable(Clock Down)
DTR State:1(Unready) RTS State:1(Unready)
DCD State:0(Ready) CTS State:0(Ready)
Note: parameters of phase adjustment: positive and negative;
Channel: main channel & Single channel
Loopback Set: No Loopback & Loopback
Error Code Test: Disable & Enable
Auto to Adjust Phase for Transmit: Enalbe & Disable
To Adjust Receive Phase: Enable & Disable
Status of DTR, RTS, DCD, CTS: Ready & Unready
Error Test Effect: Normal & Abnormal; if you disble error code test,
there will not be this item.
58
Raisecom Technology Co., Ltd
Device Set Query menu press number key 8 you can get the same information saved in
EEPROM as User-Board information (RAM)
In main menu press number key 2, there will be Cross Set Query menu:
1.Four E1 Cross Query(RAM)
2.Four User Cross Query(RAM)
3.Four E1 Cross Query(EEPROM)
4.Four User Cross Query(EEPROM)
In Cross Set Query menu, press number key 1 and there will be the following
information:
Input Group No.(1-4, Esc=Cancel):1
Enter group number 1, cross connection of the first E1 will be displayed:
First E1 Cross Set
Channel 1 2 3 4 5 6 7 8
cross 0 0 0|5 2|5 3|5 4|5 5|5 6|5 7|5 8
8 0 0|0 0|0 0|0 0|0 0|0 0|0 0|0 0
16 5 17 | 5 18 | 5 19 | 5 20 | 0 0 | 0 0 | 0 0 | 0 0
24 0 0|0 0|0 0|0 0|0 0|0 0|0 0
CROSS Query Command:1-4, Menu Display:M, Return:Q Command:
Note: in this table the address indicates the output data direction and the contents
indicate the input data direction.
Data in each cell consists of two parts, the first part indicates cross group:
1: cross group 1 2: cross group 2 3: cross group 3 4: cross group 4
5: user E1 1 6: user E1 2 7: user E1 3 8: user E1 4
And the second part indicates the channel of cross group (the first part): 1-31, 0 0
indicates there is no cross connection.
Address indication: result of row number plus column number is the channel number. For
example: (5 17),the address is 16+1=17 that is to say the data in this cell is the cross
connection of the 17th channel of first E1 (cross group 1)
59
Raisecom Technology Co., Ltd
In Cross Set Query menu, press number key 2 and there will be the following
information:
Input Group No. (1-4, Esc=Cancel):
Enter group number 1, cross connection of the first E1 will be displayed:
First User Group Cross Set
Channel 1 2 3 4 5 6 7 8
cross 0 0 0|1 2|1 3|1 4|1 5|1 6|1 7|1 8
8 0 0|0 0|0 0|0 0|0 0|0 0|0 0|0 0
16 1 17 | 1 18 | 1 19 | 1 20 | 1 21 | 1 22 | 1 23 | 1 24
24 0 0|0 0|0 0|0 0|0 0|0 0|0 0
In Cross Set Query menu, press number key 3 and there will be the following
information:
Input Group No. (1-4, Esc=Cancel):
Enter group number 1, cross connection of the first E1 information saved in EEPROM
will be displayed:
First E1 Cross Set (EEPROM)
Channel 1 2 3 4 5 6 7 8
cross 0 0 0|5 2|5 3|5 4|5 5|5 6|5 7|5 8
8 0 0|0 0|0 0|0 0|0 0|0 0|0 0|0 0
16 5 17 | 5 18 | 5 19 | 5 20 | 0 0 | 0 0 | 0 0 | 0 0
24 0 0|0 0|0 0|0 0|0 0|0 0|0 0
CROSS Query Command:1-4, Menu Display:M, Return:Q Command:
Note: in this table the address indicates the output data direction and the contents
indicate the input data direction.
Data in each cell consists of two parts, the first part indicates cross group:
1: cross group 1 2: cross group 2 3: cross group 3 4: cross group 4
5: user E1 1 6: user E1 2 7: user E1 3 8: user E1 4
And the second part indicates the channel of cross group (the first part): 1-31, 0 0
60
Raisecom Technology Co., Ltd
In Cross Set Query menu, press number key 4 and there will be the following
information:
Input Group No.(1-4, Ese=Cancel):
Enter group number 1, cross connection of the first user E1 information (cross group 5)
saved in EEPROM will be displayed:
First User Group Cross Set (EEPROM)
Channel 1 2 3 4 5 6 7 8
cross 0 0 0|1 2|1 3|1 4|1 5|1 6|1 7|1 8
8 0 0|0 0|0 0|0 0|0 0|0 0|0 0|0 0
16 1 17 | 1 18 | 1 19 | 1 20 | 1 21 | 1 22 | 1 23 | 1 24
24 0 0|0 0|0 0|0 0|0 0|0 0|0 0
In main menu press number key 3 there will be state information query menu:
1.Receive State Query
2.Transmit State Query
61
Raisecom Technology Co., Ltd
In state information query menu press number key 1 there will be the following
information:
Input Group No.(1-4, Esc=Cancel):
Enter group number 1, there will receive signal status information:
First Group Receive State
Channel 1 2 3 4 5 6 7 8
state 0 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8
8 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16
16 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24
24 25 | 26 | 27 | 28 | 29 | 30 | 31
In state information query menu press number key 2 there will be the following
information:输 Input Group No.(1-4, Esc=Cancel):1
Enter group number 1, there will transmit signal status information:
First Group Transmit State
Channel 1 2 3 4 5 6 7 8
state 0 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8
8 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16
16 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24
24 25 | 26 | 27 | 28 | 29 | 30 | 31
State Query Command:1-2, Menu Display:M, Return:Q Command:
Note: the data in each cell is hex and refer to transmit signal information of user
board, through this command you can get the device work status.
In main menu press number key 4, there will be alarm query menu:
1.Device Alarm
2.System Alarm
Alarm Query Command:1-2, Menu Display:M, Return:Q Command:
In alarm query menu press number key 1 there will be present device alarm information:
Device Alarm:
1E1 Alarm: LOMF, CRC
62
Raisecom Technology Co., Ltd
Alarms include: E1 interface alarms and line-board alarms. There are E1 interface
alarms only when that E1 interface is used, so are line-board alarms.
In alarm query menu press number key 1 there will be system alarm information:
System Alarm:
EEPROM Block: Main:Correct(T T T) E1 Block:Correct(T T T)
2M Block:Correct(T T T) Version:Correct(T T T)
User Board Com: 1:Success 3:Success
Line Board Com: Fail
Temp Sensor: Normal 30
Fans: Normal
In main menu press number key 5 and there will be set menu:
1.System Set
2.Cross Set
Set Command:1-2, Menu Display:M, Return:Q Command:
In set menu press number key 1 there will be system set menu:
1.ID Set
2.Baud Rate Set
3.Line Board Set
4.E1 Set
5.Clock Set
6.Net Topology Set
7.Alarm Sound Set
8.User Board Set
9.DCD and RTS of V35V24 Board with Alarm Set
63
Raisecom Technology Co., Ltd
10.9.1. ID set
In system set menu press number key 1 to configure Line-Board, and at present there
are three ways to configure Line-Board:
a. Without CPU the prompt will be:
The line board is 2E1 Board, it can't be set.
System Set Command:1-9, Menu Display:M, Return:Q Command:
b. With optical line-board, the menu will be:
1.Alarm Mask Set
2.Loopback Set
3.ALS Set
4.Ether Net Port Set
5.Ether Net Port Work Set
6.Transmit Band Width Set
7.Receive Band Width Set
8.Reset Ether Net
Optical Board
Set Command:1-8, Menu Display:M, Return:Q Command:
Note: the explanation of each command is available in 10.9 Line Board Set menu
64
Raisecom Technology Co., Ltd
10.9.4. E1 set
In system set menu press number key 4 to configure E1 interface and the menu will be:
1.Use Set
2.Mode Set
3.Mask Set
4.CRC Set
E1 Set Command:1-4, Menu Display:M, Return:Q Command:
The explanation of each command is available in 8.10 E1 set
In system set menu press number key 6 to configure network management channel:
Using Time Slot:0 Time Slot
In this statu use → key to change the configured value; use ↓↑to change items (using
time slot & net topology); Press ENTER to confirm configuration, press E key to finish
configuration, and ESC to cancel configuration.
Using time slots are: 0 time slot & 1 time slot
Network management topologies are: Single E1 Direction, Double E1 Dircetion, Three
E1 Dircetion and Four E1 Dircetion.
RC3000 has an assistant network management channel, with DIP –switches on front
65
Raisecom Technology Co., Ltd
panel, all RC3000 devices can be managed. To realize whole network management the
following rules must be obeyed:
If time slot 0 is network management channel, the maximum rate of serial data is
2400bps, otherwise there will be error codes.
If time slot 1 is network management channel, the serial data rate can be up to 9600bps
and time slot 1 cannot be cross connected, otherwise RC3000 will work abnormally.
Time slot is recommended.
Network management topology rule is the number of network management channels
decides the number of E1 direction as follows:
1E1 2E1
Figure 41
Three RC3000 devices make up this network and a PC can manage them all when
connected to LINK UP interface of the first RC3000.
Device 1: Set the second bit of DIP-switches ON, and others OFF; use one E1, time slot
0 and single E1 direction.
Device 2: Set all DIP-switches OFF; use two E1s, time slot 0 and double E1 direction.
Device 3: Set all DIP-switches OFF; use one E1, time slot 0 and single E1 direction.
If connect two RC3000 devices through two E1, the number of used E1 will not be same
as that of network management topology E1 directions. See in following figure:
1E1 1E1
2E1 2E1
RC3000-2E1 RC3000-2E1
Device 1 Device 2
Figure 42
When use three RC3000 devices to make up a ring, the number of used E1 will not be
same as that of network management topology E1 directions. See in following figure:
66
Raisecom Technology Co., Ltd
2E1
1E1
RC3000-2E1
1E1 1E1
2E1 Device 2 2E1
RC3000-2E1 RC3000-2E1
Device 1 Device 3
Figure 43
In this topology, the configuration of each device is as follows;
Device 1: Set the second bit of DIP-switches ON, and others OFF; use two E1, time slot
0 and single E1 direction.
Device 2: Set all DIP-switches OFF; use two E1s, time slot 0 and double E1 direction.
Device 3: Set all DIP-switches OFF; use two E1s, time slot 0 and single E1 direction.
If your configuration of any of the three devices is not same as above, there will be
device that cannot be managed. (Attention: 0nly device 2 is configured as double E1
direction).
Figure 44
Here is a more complex topology:
In this topology connect RS232 serial interface of PC with LINK UP interface of device 1,
device 1 and device 2, device 2 and device 3, device 3 and device 4, device 4 and
device 5 are connected through E1 cable, and connect LINK DOWN interface of device 2
with LINK UP interface of device 4 to realize remote network management connection.
The configuration of each device is as follows:
Device 1: Set the second bit of DIP-switches ON, and others OFF; use one E1, time slot
0 and single E1 direction.
Device 2: Set all DIP-switches OFF; use two E1s, time slot 0 and double E1 direction.
Device 3: Set all DIP-switches OFF; use one E1, time slot 0 and single E1 direction.
Device 4: Set the second bit of DIP-switches ON, and others OFF; use one E1, time slot
67
Raisecom Technology Co., Ltd
1.Input Signal
2.Output Signal
3.Signal Bit
68
Raisecom Technology Co., Ltd
Note: the command explanation is available in 8.12 V35 User Board Set menu.
When the user-board type is 8 (Ethernet data user-board), the menu will be:
1.Sub-Board Slot Number
2.Channel Select
3.Buffer Size Set
4.Default Port Mode
5.Reaet Ether Net Port
Note: the command explanation is available in 8.13 Ethernet user-board set menu.
Note: the command explanation is available in 8.14 RS232 and RS422 user-board set
menu.
In System Set menu press number key 9 to configure the alarm correlation of DCD &
RTS:
With Alarm Set:Disable
In this status use → key to change the configured value; Press ENTER to confirm
configuration, press E key to finish configuration, and ESC to cancel configuration.
When disable alarm correlation function, if the output status of DCD & CTS is normal the
V35 board will transmit data and remote DTE device does not need to reset all the time;
when enable alarm correlation function, if there are alarms of LOS, LOF and AIS, status
of DCD will be unready and if there is RAL alarm status of CTS will be unready.
This section we will explain how to configure RC3000-OPT line-board and you must first
enter the Line Board Set menu.
69
Raisecom Technology Co., Ltd
In optical line-board set menu press number key 1 to configure optical alarm mask:
Optical Alarm Mask Set:
Local Optical Loss:(Enable)
In this statu use → key to disable or enable alarm mask; use ↓↑to change items (alarms);
Press ENTER to confirm configuration, press E key to finish configuration, and ESC to
cancel configuration.
The alarms are:
Local Optical Loss;Local LOF; Local E-3 ERR; Local E-6 ERR;
Remote Optical Loss; Remote LOF; Remote E-3 ERR; Remote E-6 ERR
In optical line-board set menu press number key 2 to configure loopback of optical line:
Optical Loopback Set:
Loopback Direction:Remote
In this statu use → key to change configured value; use ↓↑to change configuration items;
Press ENTER to confirm configuration, press E key to finish configuration, and ESC to
cancel configuration.
The configuration items are:
Loopback Direction; 1E1 Loopback; 2E1 Loopback; 3E1 Loopback; 4E1 Loopback
In optical line-board set menu press number key 3 to configure ALS function (the
precondition is optical module has this function):
ALS function: Enable
In this statu use → key to change configured value (enable or disable); Press ENTER to
confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
If the optical module does not have this function there will be prompt:
Optical Model hasn't ALS function, Can't be set.
Optical Board
Set Command:1-8, Menu Display:M, Return:Q Command:
In optical line-board set menu press number key 4 to configure Ethernet interface:
Ether Net Port:Open
In this statu use → key to change configured value (open or close); Press ENTER to
confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
70
Raisecom Technology Co., Ltd
In optical line-board set menu press number key 5 to configure Ethernet interface work
status:
Ether Net Work State Set:
Auto Mode:Enable
In this statu use → key to change configured value (enable or disable); use ↓↑to change
configuration items; Press ENTER to confirm configuration, press E key to finish
configuration, and ESC to cancel configuration.
The configuration items are: Auto Mode: Enable/Disable
Port Mode: Full Duplex/Half Duplex
Port Speed: 100M/10M
AUTO_MDI/MDIX: Enable/Disable
In optical line-board set menu press number key 6 to configure Ethernet interface Tx
Band Width:
Transmit Band Width: 4095 x 32Kbps
Set (0-4095):
The first row is present configuration value and the second row is for your configuration.
If you do not set bandwidth value in the second row and just press ENTER, the old
configuration will be reserved. If you set the bandwidth value (the entering can only be
number and within the range of 0-4095) and press ENTER, the new configuration will be
effective. BackSpace key is available to modify the input value.
In optical line-board set menu press number key 7 configure Ethernet interface Rx
Bandwidth:
Receive Band Width:4095 x 32Kbps
Set(0-4095):
The first row is present configuration value and the second row is for your configuration.
If you do not set bandwidth value in the second row and just press ENTER, the old
configuration will be reserved. If you set the bandwidth value (the entering can only be
number and within the range of 0-4095) and press ENTER, the new configuration will be
effective. BackSpace key is available to modify the input value.
In optical line-board set menu press number key 8 to reset the Ethernet interface:
To run this command will reset ether net port.
71
Raisecom Technology Co., Ltd
10.11. E1 Set
72
Raisecom Technology Co., Ltd
This section will explain the command of User Board Set (with signal configurarion)
menu, including: FXS user voice card RC3000-SUB-DS, FXO voice relay card
RC3000-SUB-DO, FXS & FXO hybrid user board RC3000-SUB-DSO, E&M2 audio relay
card RC3000-SUB-DM2, E&M4 audio reley card RC3000-SUB-DM4 and magneto
telephone card RC3000-SUB-DMT.
In user board set menu press number key 2 to configure Tx signal mode:
User Board Signal Out:Original
In this statu use → key to change the configured value: Original or Anti; Press ENTER to
confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
73
Raisecom Technology Co., Ltd
In user board set menu press number key 3 to configure the signal bit:
First Channel Signal Bit:A
In this status use → key to change signal bit; use ↓↑to change configuration items; Press
ENTER to confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
Configuration items are: First Channel Signal Bit; Second Channel Signal Bit; Third
Channel Signal Bit…Last Channel Signal Bit;
In V35 user board set menu press number key 1 to configure the occupied channel
number:
User Board Slot Number=8(Can Set)
Input Slot Number (0-31):
The first row displays present configuration value and the second row is for your new
configuration.
If you do not set occupied channel number in the second row and just press ENTER, the
old configuration will be reserved. If you set the occupied channel number (the entering
can only be number and within the range of 0-31) and press ENTER, the new
configuration will be effective. BackSpace key is available to modify.
RC3000-SUB-DV35 is a data card with V35 interface and the channel number is
configurable, the rules are as follow:
a. V35 user-board can transmit data in two ways: use main cross group &
use single cross group. The first user E1 is a main cross group and channels
of this cross group will be distributed to user boards. Other user E1s are
single cross group for different slots: 1 MCU version is REV1.2 and
versions below this: user card in first slot will occupy cross group 6 (user E1
2) and user card in second slot will occupy cross group 8 (user E1 4), user
card in the third slot cannot have single cross group. 2 MCU versions are
advanced than REV1.2: cross group 6, 7 and 8 (user E1 2, 3 and 4) are
single cross group for user card in slot 1, 2 and 3.
b. The number of occupied channels for V35 user board is limited. Limitation
for single cross group: Channel number range is 0-31, 0 indicates nonuse;
the startup channel is channel 1 and there will not be channel occupation
74
Raisecom Technology Co., Ltd
collision alarms. And limitation for main cross group (user E1 1) is: when V35
user-board uses main cross group to transfer data the number of channels
will not same for different slots. Channel number range for first slot is 0-31, 0
indicates that shutdown the transmission, and the startup channel is channel
1. If other slots have already occupied the channels of main cross group
there will alarms. Channel number range for second slot is 0-23, 0 indicates
that shutdown the transmission, and the startup channel is channel 9. If other
slots have already occupied the channels of main cross group there will
alarms. Channel number range for the third slot is 0-15, 0 indicates that
shutdown the transmission of this user card, and the startup channel is
channel 17.
In V35 user board set menu press number key 2 to configure Rx data phase:
Receive Data Phase: Positive
In this status use → key to change the configured value: Positive or Negative; Press
ENTER to confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
Note: the Positive indicates the default output data phase of V35, Negative indicates the
reverse value of default data phase.
In V35 user board set menu press number key 3 to confugre Tx data phase:
Transmit Data Phase: Positive
In this status use → key to change the configured value: Positive or Negative; Press
ENTER to confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
In V35 user board set menu press number key 4 to select data channel:
Data Channel Select: Main Channel
In this status use → key to change the configured value: Main channel or Single channel;
Press ENTER to confirm configuration, press E key to finish configuration, and ESC to
cancel configuration.
75
Raisecom Technology Co., Ltd
In V35 user board set menu press number key 5 to configure loopback status of V35
user board:
Local Loopback Set:No Loopback
In this status use → key to change loopback status; use ↓↑to change configuration items;
Press ENTER to confirm configuration, press E key to finish configuration, and ESC to
cancel configuration.
Configuration items are: Local Loopback & Remote Loopback.
Note: Local loopback indicates the data loopback from V35 to V35 and Remote
Loopback indicates the data loopback from V35 to E1.
In V35 user board set menu press number key 6 to configure Error code test
Error Code Test: Disable
In this status use → key to change the configured value: Disable or Enable; Press
ENTER to confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
Note: when you start error code test, V35 user board will transmit error code periodically,
and its Rx will test the Rx data. If the Rx error code is same with that of Tx, error code
test indicator light (PAT_OK) will ON, otherwise the light will flicking or OFF.
In V35 user board set menu press number key 7 to configure the Tx data Phase Auto
Adjust function:
Auto to Adjust Phase for Transmit:Enable
In this status use → key to change the configured value: Disable or Enable; Press
ENTER to confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
Note: V35 user-board can adjust the phase of Tx data automatically.
In V35 user board set menu press number key 8 to configure the Rx data phase adjust
function:
To Adjust Receive Phase:Disable
In this status use → key to change the configured value: Disable or Enable; Press
ENTER to confirm configuration, press E key to finish configuration, and ESC to cancel
configuration.
Note: V35 user-board can adjust Rx data with a 0-degree shift, 90-degree shift and
76
Raisecom Technology Co., Ltd
180-degree shift. Disable this function and set the Rx data phase positive: the Rx data
phase will be 0 degree; disable this function and set the Rx data phase negative: the Rx
data phase will be 180 degree; enable this function and set the Rx data phase positive:
the Rx data phase will be 90 degree.
In Ethernet user-board set menu press number key 1 to configure the number of
occupied channels:
User Board Slot Number=8(Can Set)
Input Slot Number(0-31):
The first row displays present configuration value and the second row is for your new
configuration.
If you do not set occupied channel number in the second row and just press ENTER, the
old configuration will be reserved. If you set the occupied channel number (the entering
must within the range of 0-31) and press ENTER, the new configuration will be effective.
BackSpace key is available to modify.
The rule of configuring channels is the same as that of V35, please refer to the relative
section of V35 user-board set.
In Ethernet user board set menu press number key 2 to select data channel:
Data Channel Select: Main Channel
In this status use → key to change the configured value: Main channel or Single channel;
Press ENTER to confirm configuration, press E key to finish configuration, and ESC to
cancel configuration.
In Ethernet user board set menu press number key 3 to set the buffer size:
Buffer Size Set:>256Kbps
In this status use → key to change the configured value: >=2Mbps, >1Mbps, >512Kbps,
>256Kbps; Press ENTER to confirm configuration, press E key to finish configuration,
and ESC to cancel configuration.
77
Raisecom Technology Co., Ltd
In Ethernet user board set menu press number key 4 to set the default port mode:
Default Port Model:Half Duplex
In this status use → key to change the configured value: Full duplex of Half duplex;
Press ENTER to confirm configuration, press E key to finish configuration, and ESC to
cancel configuration.
Note: default port mode refers to the mode when Ethernet electric interface is LINK
DOWN, and when Ethernet electric interface is LINK UP it is in auto negotiation mode.
In Ethernet user board set menu press number key 5 to reset the Ethernet electric
interface and there will be the confirm prompt:
To run this command will reset ether net port.
Run this command (Y/N):
In this status press Y to reset the board and press N to cancel the operation. Other
enterings are invalid.
This section will explain the commands of RS232 & RS422 user-board menu:
In user board set menu press number key 1to configure channel band width::
Channel Band Width:64Kbps
In this status use → key to change the configured value: 64Kbps, 128Kbps, 256Kbps
and 512Kbps; Press ENTER to confirm configuration, press E key to finish configuration,
and ESC to cancel configuration.
Note: bandwidth set of RS232 & RS422 has not been fully realized now, and this function
is reserved.
In set menu press number key 2 there will be Cross Set menu:
1.Cross Set
2.Create Group Cross
3.Delete Group Cross
78
Raisecom Technology Co., Ltd
In cross set menu press number key 1 to configure the cross connect:
Input Group Number (1-8):
First input the cross group number:
First Channel:
There are two parts of configured data for each channel: a group number and a channel
number (there must be space between the two numbers) such as: 1 1, 0 0 indicates
deleting the cross connection of this channel. Press ENTER for the configuration of the
next channel (for unfinished entering you cannot start to configure the next channel and
the invalid data will be discarded).
Second Channel:
Press ENTER to confirm configuration (or skip that channel’s configuration and the old
value will be reserved), press E key to finish configuration, and ESC to cancel
configuration.
79
Raisecom Technology Co., Ltd
In this statu use → to change the configured value: Retain & Clear, press ENTER to
confirm.
In the configuration process press ESC to exist and the above configurations will be
invalid.
(There are seven steps of this configurarion: Group No. for Time Slot Out, Time Slot Start
No. for Time Slot Out, Group No. for Time Slot In, Time Slot Start No. for Time Slot In,
Time Slot Number for Create Cross, Create Mode:Bi-direction, Deal Mode for Old
Relation Data)
Users can use these commands when set a continuous cross connect, for example the
next cross connect is required:
Bi-direction cross connect the 1-5 channel of cross group 1 with 9-13 channels of cross
group 5 (first user E1) and clear the old configurations, you can use these commands as:
Group No. for Time Slot Out:1
Time Slot Start No. for Time Slot Out:1
Group No. for Time Slot In:5
Time Slot Start No. for Time Slot In:9
Time Slot Number for Create Cross:5
Create Mode:Bi-direction
Deal Mode for Old Relation Data:Clear
Then the required cross connect will be set.
80
Raisecom Technology Co., Ltd
Delete cross connect of cross group 1 1-5 channels and its correlation configuration:
Group No. for Delete Cross:1
Time Slot Start No. for Delete Cross:1
Time Slot Number for Delete Cross:5
Delete Releation:Clear
Then cross connect of cross group 1 1-5 channels and its correlation configuration will
be deleted.
10.17.2. Mute
In operate menu press number key 2 to mute alarm sound once and there will not be any
prompt.
81
Raisecom Technology Co., Ltd
Note: system initialization will set all configurations in 0 status, and parts restore to
factory default value. All cross set will be cleared.
In operate menu press number key 5 to save all information in RAM to EEPROM.
In operate menu press number key 7 to clear flag information of resetting device and
changing the board. And there is no prompt.
In operate menu press number key 8 the check whether watchdog can reset CPU.
Normally watchdog program will restart CPU, and in abnormal status the system cannot
exist from closed-loop.
In operate menu press number key 9 to test whether EEPROM can save data normally:
Normally there will be:
Can save data to EEPROM.
Abnormally there will be:
82
Raisecom Technology Co., Ltd
10.18. Version
In main menu press number key 8 there will be console set menu:
1.Language Select
2.Password Set
Console Set Command:1-2, Menu Display:M, Return:Q Command:
83
Raisecom Technology Co., Ltd
10.20. Quit
84
Raisecom Technology Co., Ltd
85