0% found this document useful (0 votes)
123 views1 page

HDTRH

The document provides design details for a pile cap supporting two piles. It specifies dimensions for the pile cap including a width of 800mm, length of 1900mm, and minimum depth of 1500mm. It also specifies reinforcement including sixteen millimeter diameter bars spaced at 125mm for the main reinforcement (AS1) and sixteen millimeter diameter bars for the distribution steel (AS2). The required area of the main reinforcement is 1895 square millimeters.

Uploaded by

jude
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
123 views1 page

HDTRH

The document provides design details for a pile cap supporting two piles. It specifies dimensions for the pile cap including a width of 800mm, length of 1900mm, and minimum depth of 1500mm. It also specifies reinforcement including sixteen millimeter diameter bars spaced at 125mm for the main reinforcement (AS1) and sixteen millimeter diameter bars for the distribution steel (AS2). The required area of the main reinforcement is 1895 square millimeters.

Uploaded by

jude
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

Sheet1

2 -PILE-GROUP
S = 1200

AS2
W=
700 B/2
B

L/2 AS1

L= 1900 PILE SIZE ( dia.)= 400 MM.SQ.

av PILE SPACING ( S ) = 1200 MM


Soffit of beam or slab
H= 800 MM

B= 800 MM

fcu = 35 N/MM2
AS1
d D use fy = 460 N/MM2
COL 1500
AS1 use 16 MM dia. bar
75
125 AS2 use 16 MM dia. bar
AS2
( D ) MINIMUM 900 MM
T13-250 50 LEAN CONCRETE D use 1500 MM

400 PILE WORKING LOAD ( WL ) = 1360 KN


PLAN AND SECTION
MINIMUM DEPTH OF PILE CAP ( D )

IF dia. < = 550 MM THAN D = 2.dia.+100 = 900 MM

IF DIA. > 550 MM THAN D = 1/3 ( 8.dia. - 600 ) = NA MM

d= 1375 MM

L = ( S / dia. + 1 )dia. + 300 = 1900 MM

W = dia. + 300 = 700 MM

ULTIMATE LOAD ( N ) = 2 x 1.5.WL = 4080 KN

REYNOLDS DESIGNER'S HANDBOOK - TRUSS STSTEM


TENSILE FORCE ( T ) = N ( 3S^2 - H^2 ) / 12.S.d = 758 KN

Minimum AS1 = 0.15%.W.D = 1575 MM2


AS1 required = T / 0.87.FY = 1895 MM2
OK - MORE THAN AS1. Minimum
Required 9.42 NOS. T 16
AS1 use : 32 T 16

FILE : 2PILEG