Electronic Control Module (ECM) : Systems Operation
Electronic Control Module (ECM) : Systems Operation
Page 1 of 2
Shutdown SIS
Previous Screen
Product: EXCAVATOR
Model: 320 EXCAVATOR YBP
Configuration: 320 Excavator YBP00001-UP (MACHINE) POWERED BY C7.1 Engine
Systems Operation
Bluetooth Operator ID and Machine Security System (MSS)
Media Number -M0083909-02 Publication Date -01/10/2018 Date Updated -25/10/2018
i07057616
Illustration 1 g00785019
Electronic Control Module (ECM)
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/... 7/14/2019
320 Excavator YBP00001-UP (MACHINE) POWERED BY C7.1 Engine(M0092767 - 0... Page 2 of 2
The Machine Security System (MSS) is an integrated feature for the machine ECM. The MSS
software and components are integrated into an ECM that controls other machine functions.
ECM Inputs
Push-to-Start Switch or Keyswitch
The push-to-start switch or key start switch is also used as an input signal to the MSS. The input from
the key switch is used to determine when the machine is ON. Battery voltage is connected to this
input through the ON and START positions of the keyswitch. See Table 1 for input voltages.
Table 1
Input Voltage 12V System 24V System
Machine is operating and the alternator is charging. 14.1 - 15.1V 27.6 - 29.6V
Machine is not running. 12V 24V
ECM Outputs
Status Indicator
The status indicator displays the status of the system. The status indicator has two connections. One
connection is for the red LED. The other connection is for the green LED.