Manual

This document provides instructions for operating the XMTG-2301-J digital temperature controller. It uses digital displays and time proportioning control methods. The controller has high precision, reliability, and is easy to install. It is used to automatically control temperature in various industrial applications like metallurgy, chemicals, and more.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4K views1 page

Manual

This document provides instructions for operating the XMTG-2301-J digital temperature controller. It uses digital displays and time proportioning control methods. The controller has high precision, reliability, and is easy to install. It is used to automatically control temperature in various industrial applications like metallurgy, chemicals, and more.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

XMTG-2301-J digital temperature controller

Operation Instruction
XMTG-2301-J temperature controller adopts digital display of the measureed temperature and
method of time proportion control. It has high precision、good reliability、strong cushioning、easy
installation and other advantages. This controller is widely used as temperature measurement and
control automatically in light and heavy industry ,such as ,metallurgy、chemical、electronic、machinery、
textile、plastic、refrigeration、medical treatment、electric oven and so on.

A.Technical specification:
1. Input type: J
2. Range: 0~399℃
3. Accuracy: ≤ 1.0%F.S ±1B
4. Contact capacity: 220VAC, 7A(resistance load)
5. Power supply: AC85~ 242V 50/60HZ
6. Power consumption : < 3W
7. Overall size and installation hole : 48×48×110mm ; 44×44mm
8. Working environment: temperature: 0~50℃; relative humidity: < 85% RH, without corrode
gas .

B. Connection Scheme(consult):

C. Method to use:
Connect the power and the sensor according to the connection Scheme,then it displays the actual
measured temperature.
The terminals of ‘1’, ‘2’ are input of thermocouple signal, the terminals of ‘6’, ‘7’, ‘8’ are relay control
output. When the green light of " OU T" brighten, termin al '7' and '8' are connected and terminal '6' and '7' are
disconnected. When the green light of "OUT" goes out, terminal '7' and '8' are disconnected and terminal '6' and '7'
are connected. The terminal of '9', '10' are power supply(AC85~242V).
When the actual measured temperature don’t enter the proportional band and the setting temperature is
higher than the actual measured temperature, the terminal “7” and “8” connect, terminal “7” and “6”
disconnect. The load starts heating at this time and its temperature is going up.
When the actual measured temperature don't enter the proportional band and the setting temperature is
lower than the actual measured temperature, the terminal “7” and “8” disconnect, terminal “7” and “6”
connect. The load does not heat at this time and its temperature is going down.
After the actual measured temperature entry into the proportional band, the relay start opening and
closing according to the controlling rule. The higher temperature, the shorter connecting time of relay
between terminal “7” and “8 ”. Vice versa .The controller controls the temperature by the way of
changing the average heating power of load.

D. The maintenance and attention of controller.


1. The controller should be installed in the condition without corrode gas.
2. Thermocouple should be put in the place where it can measure real temperature inside the furnace and
has good insulation with heating element of furnace.
3. Before powering on the controller, please check it carefully to see if all connection is correct and if
thermocouple can match with input type of controller.
4. When heating initially, although the power of heating element inside furnace has been turned off, the
temperature of furnace will keep going up because of the heating inertia inside furnace. So it is better
to set about 80% of temperature you want to set normally before powering on the controller every time.
After controller carry out “on-off control “for several times, then set temperature value you want to set
normally, so as to avoid over surging.
5. If the controller displays abnormally, check the sensor to see if its connection is open circuit or short
circuit, also check if the working voltage of controller is normal.