ISOLATED FOOTING DESIGN
FORCES DETAILS :
Axial Load = P1 = 1.3 T
Moment along Major axis = Mx = 3.50 T-m
Moment along Minor axis = Mz = 0 T-m
COLUMN DETAILS : G.L
Length = ( Larger Dimension of Column ) 0.45 m
Width = ( Smaller Dimension of Column ) 0.45 m
FOOTING DETAILS :
Length = L = 2 m
Width = B = 1.5 m 1.0
Depth = D = 0.3 m
Cover to Main R/f = 0.05 m
Diameter of R/f in Footing = 12 mm
0.3
SOIL DETAILS :
Density of Soil = g = 2.5 T/m3
Depth of foundation below G.L = H = 1.3 m 2.00
Soil Weight above Footing = 6.99 T X
MATERIAL CONSTANT :
Concrete Grade = M - 25 N/mm2
R/f Grade = Fe - 415 N/mm2 1.50
Load Factor = gf = 1.5 Z Z
DESIGN FORCES :
Axial load = P = 1.30 T
Self Weight of Footing = 2.25 T X
2.00
Total Vertical Load = 10.54 T
Moment along Major axis 3.5 T-m
Moment along Minor axis 0 T-m
PRESSURE CALCULATION :
SBC = 20 T/m2
FOR EARTHQUAKE CONDITION ALLOWABLE S.B.C = 1.25 x 20 = 25 T/m2
P + Mx + Mz
P=
A - Zx - Zz
\ Pmax = 3.51 + 3.50 + 0 = 7.01 T/m2 < S.B.C SAFE
\ Pmin = 3.51 - 3.50 - 0 = 0.01 T/m2 TENSION NOT CREATED
R/F CALCULATION FROM BENDING CONSIDERATION :
2000
525
1500 450
450
775
0.0
T/M2 7.0
T/M2
MOMENT AT CRITICAL SECTION ALONG WIDTH :
M = Pmax x 0.525 x 0.525 / 2
M= 0.97 T-m
Mu = 14.50 KN-m
Ast = 162.48 mm2 ( To be distributed in 2 m Length )
Min Req = 360 mm 2
( Ast = 0.12 x b x D )
Required Spacing of Bar = 12 # @ 310 C/C ALONG WIDTH
PROVIDE 12 # @ 200 C/C ALONG WIDTH
\ Ast = 565.49 mm2
MOMENT AT CRITICAL SECTION ALONG LENGTH :
M = Pmax x 0.775 x 0.775 / 2
M= 2.11 T-m
Mu = 31.60 KN-m
Ast = 358.80 mm2 ( To be distributed in 1.5 m Length )
Min Req = 360 mm2 ( Ast = 0.12 x b x D )
PROVIDE 12 # @ 310 C/C ALONG LENGTH
\ Ast = 364.83 mm2
CHECK FOR ONE WAY SHEAR ALONG LENGTH :
Critical Section is at diatance of ' d ' from face of column
0.525
1.50 0.775 0.525
2.00
\ Shear force at critical section = 7.01 x 0.525
V = 3.68 T
Vu
\ Actual Shear stress tv =
bxd
1.5 x 3.68
= x 10000
1000 x 250
= 0.221 N / mm2
Pt = 100 x As = 100 x 364.83 = 0.15 Pt tc
b x d 1000 x 250 0.15 0.28
0.2 0.33
\ tc = 0.28 N / mm2
< tv
HENCE SAFE
CHECK FOR ONE WAY SHEAR ALONG WIDTH :
Critical Section is at diatance of ' d ' from face of column
0.525
1.50 0.775
0.275
2.00
\ Shear force at critical section = 7.01 x 0.275
V = 1.93 T
Vu
\ Actual Shear stress tv = bxd
1.5 x 1.93
= x 10000
1000 x 250
= 0.116 N / mm2
100 x As 100 x 565.49
Pt = = = 0.23
b x d 1000 x 250
\ tc = 0.28 N / mm2
< tv
HENCE SAFE
CHECK FOR TWO WAY SHEAR :
Critical Section is at distance of 'd/2' from face of column
2.00
0.7
1.50 0.7 d/2
d/2
\ Shear force at Critical Section = 7.01 x Area of Shadeded Portion
= 7.01 x 2.51
= 17.61 T
Critical Perimeter = 2 x 0.7 + 2 x 0.7
= 2.80 m
Vu
\ Actual Shear stress tv = bxd
1.5 x 17.61
= x 10000
2800.00 x 250
= 0.377 N / mm2
Allowable Shear stress = ks.tc ( CLAUSE 31.3.3 IS 456 : 2000 )
where,
ks = ( 0.5+b )
Short Side of Column = 0.45
b= Long Side of Column = 0.45
= 1.00
ks = 1.50 but not greater than 1.0
Where,
tc = 0.25 Ö fck
tc = 0.25 Ö M - 25 = 1.25 N/mm2
Allowable Shear stress = ks.tc = 1.25 N/mm2 SAFE
CHECK FOR OVERTURNING :
ALONG LENGTH :
Rm Restoring Moment = 10.54 x 1.00
Rm = 10.54 T.m
Applied Moment = 3.5 T.m
Restoring Moment
F.O.S. =
Applied Moment
P 10.54
= = 3.01
3.5
> 2
SAFE
1.00