0% found this document useful (0 votes)
131 views6 pages

Solated Footing

This document provides details for designing an isolated square footing to support a column. Key details include: - The column has dimensions of 0.45m x 0.45m and transmits loads of 1.3T axial and 3.5T-m moment. - The proposed footing has dimensions of 2m x 1.5m x 0.3m deep with 12mm diameter reinforcement bars at a cover of 0.05m. - Calculations are shown to check capacity for pressure, bending moments, shear strength, and overturning. All checks show the footing design is safe and meets code requirements.

Uploaded by

Sathish Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
131 views6 pages

Solated Footing

This document provides details for designing an isolated square footing to support a column. Key details include: - The column has dimensions of 0.45m x 0.45m and transmits loads of 1.3T axial and 3.5T-m moment. - The proposed footing has dimensions of 2m x 1.5m x 0.3m deep with 12mm diameter reinforcement bars at a cover of 0.05m. - Calculations are shown to check capacity for pressure, bending moments, shear strength, and overturning. All checks show the footing design is safe and meets code requirements.

Uploaded by

Sathish Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 6

ISOLATED FOOTING DESIGN

FORCES DETAILS :
Axial Load = P1 = 1.3 T
Moment along Major axis = Mx = 3.50 T-m
Moment along Minor axis = Mz = 0 T-m

COLUMN DETAILS : G.L


Length = ( Larger Dimension of Column ) 0.45 m
Width = ( Smaller Dimension of Column ) 0.45 m

FOOTING DETAILS :
Length = L = 2 m
Width = B = 1.5 m 1.0
Depth = D = 0.3 m

Cover to Main R/f = 0.05 m


Diameter of R/f in Footing = 12 mm
0.3
SOIL DETAILS :
Density of Soil = g = 2.5 T/m3
Depth of foundation below G.L = H = 1.3 m 2.00

Soil Weight above Footing = 6.99 T X

MATERIAL CONSTANT :
Concrete Grade = M - 25 N/mm2
R/f Grade = Fe - 415 N/mm2 1.50
Load Factor = gf = 1.5 Z Z

DESIGN FORCES :
Axial load = P = 1.30 T
Self Weight of Footing = 2.25 T X
2.00

Total Vertical Load = 10.54 T

Moment along Major axis 3.5 T-m


Moment along Minor axis 0 T-m

PRESSURE CALCULATION :
SBC = 20 T/m2
FOR EARTHQUAKE CONDITION ALLOWABLE S.B.C = 1.25 x 20 = 25 T/m2

P + Mx + Mz
P=
A - Zx - Zz

\ Pmax = 3.51 + 3.50 + 0 = 7.01 T/m2 < S.B.C SAFE

\ Pmin = 3.51 - 3.50 - 0 = 0.01 T/m2 TENSION NOT CREATED


R/F CALCULATION FROM BENDING CONSIDERATION :

2000

525

1500 450

450
775

0.0
T/M2 7.0
T/M2

MOMENT AT CRITICAL SECTION ALONG WIDTH :

M = Pmax x 0.525 x 0.525 / 2


M= 0.97 T-m
Mu = 14.50 KN-m
Ast = 162.48 mm2 ( To be distributed in 2 m Length )
Min Req = 360 mm 2
( Ast = 0.12 x b x D )

Required Spacing of Bar = 12 # @ 310 C/C ALONG WIDTH

PROVIDE 12 # @ 200 C/C ALONG WIDTH

\ Ast = 565.49 mm2


MOMENT AT CRITICAL SECTION ALONG LENGTH :

M = Pmax x 0.775 x 0.775 / 2


M= 2.11 T-m
Mu = 31.60 KN-m
Ast = 358.80 mm2 ( To be distributed in 1.5 m Length )
Min Req = 360 mm2 ( Ast = 0.12 x b x D )

PROVIDE 12 # @ 310 C/C ALONG LENGTH

\ Ast = 364.83 mm2

CHECK FOR ONE WAY SHEAR ALONG LENGTH :

Critical Section is at diatance of ' d ' from face of column

0.525

1.50 0.775 0.525

2.00

\ Shear force at critical section = 7.01 x 0.525

V = 3.68 T

Vu
\ Actual Shear stress tv =
bxd

1.5 x 3.68
= x 10000
1000 x 250

= 0.221 N / mm2

Pt = 100 x As = 100 x 364.83 = 0.15 Pt tc


b x d 1000 x 250 0.15 0.28
0.2 0.33
\ tc = 0.28 N / mm2

< tv
HENCE SAFE
CHECK FOR ONE WAY SHEAR ALONG WIDTH :

Critical Section is at diatance of ' d ' from face of column

0.525

1.50 0.775

0.275
2.00

\ Shear force at critical section = 7.01 x 0.275

V = 1.93 T

Vu
\ Actual Shear stress tv = bxd

1.5 x 1.93
= x 10000
1000 x 250

= 0.116 N / mm2

100 x As 100 x 565.49


Pt = = = 0.23
b x d 1000 x 250

\ tc = 0.28 N / mm2

< tv

HENCE SAFE
CHECK FOR TWO WAY SHEAR :

Critical Section is at distance of 'd/2' from face of column

2.00

0.7

1.50 0.7 d/2

d/2

\ Shear force at Critical Section = 7.01 x Area of Shadeded Portion

= 7.01 x 2.51

= 17.61 T

Critical Perimeter = 2 x 0.7 + 2 x 0.7

= 2.80 m

Vu
\ Actual Shear stress tv = bxd

1.5 x 17.61
= x 10000
2800.00 x 250

= 0.377 N / mm2

Allowable Shear stress = ks.tc ( CLAUSE 31.3.3 IS 456 : 2000 )

where,
ks = ( 0.5+b )

Short Side of Column = 0.45


b= Long Side of Column = 0.45
= 1.00

ks = 1.50 but not greater than 1.0


Where,
tc = 0.25 Ö fck
tc = 0.25 Ö M - 25 = 1.25 N/mm2

Allowable Shear stress = ks.tc = 1.25 N/mm2 SAFE

CHECK FOR OVERTURNING :


ALONG LENGTH :

Rm Restoring Moment = 10.54 x 1.00

Rm = 10.54 T.m

Applied Moment = 3.5 T.m

Restoring Moment
F.O.S. =
Applied Moment

P 10.54
= = 3.01
3.5

> 2