Ambient conditions
Installation altitude at height above sea level
Main circuit
Number of poles for main current circuit 3
Number of NO contacts for main contacts 3
Number of NC contacts for main contacts 0
Operating current
● at AC-1 at 400 V
— at ambient temperature 40 °C rated value 40 A
● at AC-1
— up to 690 V at ambient temperature 40 °C 40 A
rated value
— up to 690 V at ambient temperature 60 °C 35 A
rated value
● at AC-3
— at 400 V rated value 12 A
● at AC-4 at 400 V rated value 12.5 A
Operating current
● at 1 current path at DC-1
— at 24 V rated value 35 A
— at 110 V rated value 4.5 A
● with 2 current paths in series at DC-1
— at 24 V rated value 35 A
— at 110 V rated value 35 A
● with 3 current paths in series at DC-1
— at 24 V rated value 35 A
— at 110 V rated value 35 A
Operating current
● at 1 current path at DC-3 at DC-5
— at 24 V rated value 20 A
— at 110 V rated value 2.5 A
● with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value 35 A
— at 110 V rated value 15 A
● with 3 current paths in series at DC-3 at DC-5
— at 24 V rated value 35 A
— at 110 V rated value 35 A
Operating power
● at AC-1
— at 400 V rated value 23 kW
● at AC-2 at 400 V rated value 5.5 kW
● at AC-3
Auxiliary circuit
Number of NC contacts for auxiliary contacts
● instantaneous contact 0
Number of NO contacts for auxiliary contacts
● instantaneous contact 0
Operating current at AC-12 maximum 10 A
Operating current at AC-15
● at 230 V rated value 6 A
● at 400 V rated value 3 A
Operating current at DC-12
● at 60 V rated value 6 A
● at 110 V rated value 3 A
● at 220 V rated value 1 A
Operating current at DC-13
● at 24 V rated value 10 A
● at 60 V rated value 2 A
● at 110 V rated value 1 A
● at 220 V rated value 0.3 A
Contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA)
Short-circuit protection
Design of the fuse link
● for short-circuit protection of the main circuit
Connections/Terminals
Type of electrical connection
● for main current circuit screw-type terminals
● for auxiliary and control current circuit screw-type terminals
Type of connectable conductor cross-sections
● for main contacts
— solid 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 2x 10 mm²
— single or multi-stranded 2x (1 ... 2,5 mm²), 2x (2,5 ... 6 mm²), max. 2x 10 mm²
— finely stranded with core end processing 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
● at AWG conductors for main contacts 2x (16 ... 12), 2x (14 ... 10), 1x 8
Type of connectable conductor cross-sections
● for auxiliary contacts
— solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG conductors for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 1x 12
Certificates/approvals
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT1024-1AB00
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT1024-1AB00
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RT1024-1AB00
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT1024-1AB00&lang=en
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RT1024-1AB00/char
Further characteristics (e.g. electrical endurance, switching frequency)
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT1024-1AB00&objecttype=14&gridview=view1
45 62
28 5 38
35
SIEMENS 48 5
69
72
60
85