Ascon
Ascon
Ascon
Multi-output or
Ascon Tecnologic S.r.l.
via Indipendenza 56,
Multi-set point Controller
27029 - Vigevano (PV)
Tel.: +39 0381 69871, XS Series
Fax: +39 0381 698730
INSTRUCTION MANUAL
MIU.XS-6/96.10/E
COD J30-154-1AXS ING
SERIAL COMMUNICATION
(see DIRECTIONS FOR USE “serial communication
supplement” MIU.XS-CS/E supplied separately)
2
1 • IDENTIFICATION OF MODEL
Power supply A
100 …240 V 50/60 Hz 3
16 …28 V 50/60 Hz and 20…30 Vdc 5 275.8
Serial communications B 275.8
None 0 4 50
20mA C.L. Std Ascon protocol 1
20mA C.L. Modbus/Jbus protocol 2
OPTIONS
Retransmission output Y4 C
None 0
Fitted (4...20 mA or 0...10 Vdc) 1
Set point D
Standard
(up to 4 mem. or Loc./Rem.) 0
Time-programmable 1
(11 segments)
1
1 • IDENTIFICATION OF MODEL
Model code
Input X E
275.8
275.8
1st part
F 4 50
Main output Y1 G
H
OPZIONI
Auxiliary output Y2 I
part
Auxiliary output Y3 L
2nd
Retransmission output Y4 M
Set point W N
2
2 • FUNCTION OF KEYS AND DISPLAYS
275.8
Waiting - programme in course 15
Active Remote Set 11
2 Set point W
275.8
Active serial communication 13 10 Manual operation
Mem. programme in execution 14 3 Main output % Y1
5
4 50
Auxiliary N° 4 7 Main output Y1 “ON”
6 7a Main output Y1 (heat)
Auxiliary output Y3 “ON” 9 7b Main output Y1F (cool)
Auxiliary output Y2 “ON” 8 16 Set point
18 Increment digit
Functions (menu) 19
17 Select digit
Face seal IP54
20 Confirm data
Withdrawal screw 21 Automatic / Manual
Front cover
NUMERIC INDICATORS X, W, Y, N°
1 - Measure X The value of measure X is expressed in engineering
units.
8888
____
(green)
If above end of scale
If below beginning of scale 8888
----
10
275.8 - In programmation: displays parameter values
- In configuration: displays the values of the 1st part
of the configuration code (see enclosed leaflet)
4
which case led 5 "W" lights up too
7.5 b - the N° of the segment in execution (option with
a
4 b4 programmable set, see chapter 11) in this case,
led 6 "SG" lights up too
3
2 • FUNCTION OF KEYS AND DISPLAYS
Loop -
275.8 With output Y3 active and configured as
275.8 Loop Break Alarm, the front displays X and
Break - 4 50 W are flashing (see p. 14)
Alarm
4
2 • FUNCTION OF KEYS AND DISPLAYS
KEYS
16 - Set Point Standard configuration:
(1 Local + 4 storable used for:
• modifying the Set point
• recalling the 4 memorized Set points
(see enclosed leaflet)
Remote Set configuration:
(1 Local + 1 Remote) used for:
• passing from Local to Remote Set point
and viceversa (see enclosed leaflet)
Programmed Set configuration:
(see chapter 11)
• to recall the Local operating Set point
• to start, stop, start again the
execution of the memorized programme
5
3 • DIMENSIONS - INSTALLATION
96
W - +
F A/M
110 min.
150 min.
with
protection
Ring with hook IP65
Front cover
projection and locking screw +0.8
92
Advised +0.6
45
thickness 1 ÷ 16
Wiring protection plate Panel apertures
Holding
hooks
AMBIENT
Temperature: 0 ÷ 50°C Locking
! Humidity : 30 ... 85uR%
Seal ring fitting screws
! Do NOT force
cross-screwdriver labels supplied
Bar rh
6
4 • ELECTRICAL WIRING
Wiring
protection plate
2
Rotate
downwards
Plate screw
Cold joint
compensation 3 gilded
thermometer terminals for
input signals
2
6.9 max.
With fork
terminals 1
Rotate
1 7
upwards
0.25 ÷ 2.5
6.9 max. AWG
22 ÷ 14
2
Depress the plate to
engage the pin
With tinned wire
2
6÷7
Preferential
7
4 • ELECTRICAL WIRING
Serial communication A
Analogic inputs B
Logic inputs and analogic A B C E A B C E
signals C
Channel for low level signal conductors
Input D
Outputs E
Wiring diagram
8
4 • ELECTRICAL WIRING
Schema
1 • Singledipower
collegamento
supply
"Switching" type
11 • Standard: 100 to 240 Vac - 15% + 10%
Single power supply • for low tension: 24 Vac -15% + 10%
12 24 Vdc ±15%
Absorbed power 4VA
7 7 7
X
Input mA, Volt Rj Transmitter Rj Rj
i
9 9 9
Rj = 30 Ω per mA Transmitter
Rj = 10 KΩ per Volt com.
9
4 • ELECTRICAL WIRING
Schema
3 • Remote
di collegamento
Set point input
Rj = 30 Ω per mA
Ri = 330 KΩ per V
In current 4..20 mA
In voltage 0..10 Vdc
5
Remote Set point mA, Volt Rj NOT galvanically
25 ! isolated
4 • Logic inputs
External contacts COM
21 An impulsive (2 sec. at least) closing
H C1 of contacts C1, C2, C3, permits the
IL1
22 passage from AUTO/MAN, from
H C2 Local/Remote Set point, recalling the
IL2
23 4 memorized Set points and
H C3
IL3 launching of the programmed Set
24 point. (see p. 16)
5 • Main output Y1
10
4 • ELECTRICAL WIRING
C • single in voltage !
Load Continuous
Position the switch set
19 output 0..10Vdc inside the controller too
500 Ω
Y1 galvanically
min.
20 isolated
2 3
1
D • single logic
Load Output 0/18Vdc 1 Continuous output
19 (20mA max.) 4...20mA Standard
Y1 V~ galvanically 2 Continuous output
isolated 0...10Vdc
20 3 Logic output
Relay or static contactor 0...18Vdc
E • Dual action relay For controllers with dual action output Y1 (example:
NA Heat-Cool), an extra output Y1F with Relay is available
17 for the cooling action. If a continuous output is desired
Y1F V~ for cooling, use the retransmission output Y4 (option)
configured for retransmission of the signal: Y1F (cool).
18 Possible combinations for Y1 dual are:
Load
resistive loads 5A \ 250 Vac Terminals 16 - 17 19 - 20 16-17 19 - 20
Y1 ▲ (Heat) R R L L C C R C L
F • Continuous dual action Y1 ▼ (Cool) R L* R L* L* R C C C
Terminals 17 - 18 28 - 29
where: R = Relay L = Logic C = continuous (mA or Volt)
Load *version on request
28 For Y1 cool, R is the extra relay of Y1, while C is the
retransmission output Y4 configured to retransmit Y1
500 Ω Y4 cool: 4...20mA or 0...10 Volt.
min. 29 Output feature of dual action controllers
Cool - 100% Heat 100%
Retransmission output Y1F (option)
Y1F limit Dead Y1C limit
galvanically isolated (0…-100%) (0…100%)
zone
4...20mA, 10Vdc max. or
0...10Vdc, 20mA max. Y1F = output
cool
See retransmission Cool Heat Y1C = output
! output Y4 -100% 0 0 100%
heat
11
4 • ELECTRICAL WIRING
Retransmission:
of measurement X
of Set point W A 4…20 mA V 0…10 Vdc
of output Y1F (Cool) ;
If the retransmission signal must be changed (4…20 mA
0…10 V or viceversa) it is necessary to perform a new
calibration to return to the declared tolerance (±0.1%).
Standard calibration is for mA, to receive an instrument
with the desired Voltage calibration, specify the proper
mConfiguration Code in the order module
Note
Zener 2,7 V Only for 20mA C.L.
12
5 • Y2 - Y3 AUXILIARY OUTPUTS
Deviation
On Active high Set point W (1)
W1 Off (above) -300...+300 steps
compared to W1
Active low
H (under)
∆W
Band
On Active out Set point I WI (1)
W1 Off (above) -0...300 steps
compared to W1
Active in
H H (under)
I∆WI I∆WI
Independent
On Active high Set point (1):
W1 Off (above) from beginning
On to end of scale
Off Active low
H (under)
W
(1) - The Set point of Y2 and Y3 is not limited by the limits of the main
Set point W1, but only by the scale span.
Deviation with startup inhibition
inhibition
∆W
W1
On
Off
Active high Set point W (1)
Startup (above) -300...+300 steps
compared to W1
W1
Active low
∆W
inhibition (under)
On
Off
Startup
13
5 • Y2 - Y3 AUXILIARY OUTPUTS
mA
°C
Time-programmable intervention
14
6 • PASSWORD
WpAss
Enter password of access to configuration
(see enclosed leaflet)) 3333
NO
Return to normal
OK function
YES
Introduction into configuration
NO
Return to normal
OK function
YES
Introduction into the 5th group
15
9 • MODIFYING THE OPERATING STATE
Interface
No action
ON Passage from REMOTE to LOCAL
ON Passage from AUTOMATIC to MANUAL
ON ON Passage from MANUAL to AUTOMATIC
passage
ON Local Sp. to Remote Sp.
Local Sp. = Memorized Sp. 1 Programme startup RUN
Local Sp. = Memorized Sp. 2 __ Passage to successive
ON ON
segment (NEXT)
Local Sp. = Memorized Sp. 3 __ Temporary stop
ON ON of programme HLD
Local Sp. = Memorized Sp. 4 __ Restart after stop of
ON ON ON
programme
Note 1: Is possible to fix the selected Set point holding closed the relative contacts.
While they are closed is possible to make changment from Auto/Man or Man/Auto but
it is not possible to change Set point
16
12 • TECHNICAL DATA
Expert - Tune For continuous optimization of the parameters during normal operation.
Auto/Man With bumpless action, AUTO/MAN transfer via keyboard, logic input and serial
Station communication.
17
12 • TECHNICAL DATA
18
WARRANTY