DT 7550

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

❶ Select the mounting location. ❷ Separate the sensor housings and ❸ Mount the unit.

remove the printed circuit board (PCB).

Wall Mount Corner


Mount

For improved anti-mask Wire Channel


Mounting Location Guidelines performance the look-down
• 2.3 m (7’6”) mounting height. mirror is disabled. To enable
• Avoid direct or reflected sunlight. look-down remove the mask.
• Aim sensor away from windows or heating/ • Slide the wire through the wire channel in the
cooling devices. back housing.
• Sensor must have a clear line-of-sight to • Use a small screwdriver to unfasten the housing • Mount the back housing flat against a wall or in a
protected area. latch. Gently pull apart the housings. corner.
• Push outward on the PCB latch and lift the PCB • Replace the PCB.
out of the housing.

❹ Wire the unit. ❺a Walk-test the sensor. ❺b Optional: Walk-test using Zone Finder
50% 75% Use the Zone Finder mode to identify the PIR and/or
microwave pattern. In Zone Finder mode the red LED
Power is disabled.
Trouble Tamper Alarm 25% 100%
40 mA
125 mA 50 mA 125 mA 7.5-16 VDC
25 VDC 24 VDC 25 VDC (For UL 8.0-16 VDC)

• Set Switch 3 to select the appropriate fluorescent


TBL TBL T T NO C EOL NC V- V+ light filter (see Dip Switch chart on the next page).
• Apply power to the unit. Initialization is complete when
the LED stops flashing slowly.
• Connect wires as shown using 0.3 - 1.0 mm2 • Adjust the microwave range to minimum setting
(18 to 22 gauge) wire size. Observe proper (25%) by turning the range adjustment counterclock-
polarity. • Use a screwdriver to short the test pads.
wise using a small screwdriver.
• During the Zone Finder walk-test mode, the LED
• Replace the front housing.
turns:
• Begin walking through the detection area.
- green for one second for every PIR detection;
- The LED will turn red, indicating an alarm detection.
- yellow for two seconds for every microwave
• Increase the microwave range as necessary.
detection.
• Repeat the items in step 5a until proper detection
range is obtained. • Adjust the microwave range as necessary.
• Zone finder mode times out after ten minutes.

DT-7550C DUAL TEC® With Anti-Mask Motion Sensor Installation Instructions


• The sensor MUST be walk tested after every power
up to complete the power up mask detection test.
LED INDICATORS POWER UP ANTI-MASK (Patent Pending) PRODUCT SPECIFICATIONS
At power up, the DT-7550C initiates the power up mask detection test. The Range:
OPERATION MODE power up mask test will be completed ONLY after both the PIR and 15 m x 18 m (50' x 60')
LED Power requirements:
Normal Microwave technologies are verified by a walk test and an alarm is signaled.
Power Up Trouble Zone Finder 7.5 - 16 VDC (UL 8.0 - 16 VDC, .60W)
If not walk tested, the DT-7550C remains in power up mask testing mode 30 mA typical, 40 mA maximum, 12 VDC
ON Slow Fast OFF indefinitely, and will issue a mask signal if a set number of microwave events AC Ripple: 3 V peak-to-peak at nominal 12 VDC
Red
Alarm Blink Blink occur before a PIR event. Alarm relay:
ON The DT-7550C MUST be walk tested after every power up to complete the Energized Form C
OFF OFF ON 125 mA, 25 VDC, 20 Ohm series resistor
Yellow mask detection test.
Microwave Microwave Trouble relay:
ON NORMAL OPERATION De-energized Form B
OFF OFF ON (NC) 125 mA, 25 VDC
Green The DT-7550C signals a mask condition when reflective objects are placed
PIR PIR Tamper switch:
in front of the sensor. Follow the mounting guidelines as shown in Step 1.
(NC) 50 mA, 24 VDC

ON
Microwave frequencies:

1
DIP SWITCH SETTINGS (SW1) TROUBLE FUNCTION
2 24.125 GHz
3
Factory default settings are shown in grey. Sensor Status Trouble Relay LED RFI immunity:
Normal Closed Normal 30 V/m,10 MHz - 1000 MHz
OFF ON PIR white light immunity:
Switch Self-test Failure Open Trouble Flash 6,500 Lux typical
1 Low Sensitivity High Sensitivity Mask Open Normal Fluorescent light filter:
(Pulse Count 2) (Pulse Count 1) 50 Hz or 60 Hz selectable
2 LED Disabled LED Enabled DETECTION PATTERNS Sensitivity:
Top View Low (pulse count 2) 3 - 4 steps
3 60 Hz Fluorescent Filter 50 Hz Fluorescent Filter Wide Angle Lens High (pulse count 1) 2 - 3 steps
Operating temperature:
TROUBLE SHOOTING 14o F to +131o F (-10o C to +55o C)
(Indoor use environment)
Problem: Red LED is flashing rapidly, trouble relay is actuated. Relative Humidity:
Explanation: The sensor is in one of three conditions: 5 to 95%; non-condensing
* Look-down fingers Temperature compensation:
Microwave supervision failure: The sensor continues operating using PIR as the only
Advanced dual slope
detection method. When detection occurs on the PIR channel, the alarm relay will latch are enabled only when
the look-down mask is PIR fields-of-view:
open until the Microwave trouble is removed. 22 long range edges
removed (see Step 2).
12 intermediate edges
PIR self-test failure: Alarm relay does not actuate.
6 lower edges
Temperature compensation failure: When alarm occurs, the alarm relay will latch open *4 Look-down edges
until the trouble is cleared. Self-tests:
Microwave Supervision, PIR self-test
Solution: Power down the sensor or enter zone finder mode which will perform self-test. Temperature Compensation
If the trouble does not clear, replace the sensor. Weight:
Side View
6.53 oz (185 g)
Problem: Trouble relay is actuated without red LED flashing.
Packaged Product Approx: 7.84 oz (222 g)
Explanation: Anti-mask condition is detected. Dimensions:
Solution: Verify the sensor was walk-tested after power up to ensure the power up mask 11.9 cm H x 7.1 cm W x 4.2 cm D
(4.685" H x 2.795" W x 1.654" D)
detection test was completed. Verify that the sensor is not masked or blocked. Walk
Accessories Available:
through the detection pattern. Replace the sensor if it does not clear. FCC Notice: This equipment has been tested and found to comply with the limits for a Class B digital device, Optional Lens Kit --
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if
Long Range Curtain Lens Kit (P/N DT7000-LRLK)
not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Note: The function of this optional lens with this sensor has
MASK FUNCTIONS However, there is no guarantee that interference will not occur in a particular installation. If this equipment does not been evaluated by Underwriters Laboratories Inc.
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
Mounting Brackets --
The DT-7550C detects a variety of masking materials and objects. When it determines SMB-10 Swivel Mount Bracket (P/N 0-000-110-01)
• Reorient or relocate the receiving antenna.
the presence of a mask, the DT-7550C sensor signals a trouble condition. • Increase the separation between the equipment and receiver. SMB-10C Swivel Mount Ceiling Bracket
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (P/N 0-000-111-01)
A visual inspection and walk-test is recommended for all trouble signals. The sensor • Consult the dealer or an experienced radio/TV technician for help.
SMB-10T Swivel Mount Bracket w/Tamper
clears a mask condition when it detects motion on the PIR and microwave technologies. Changes or modifications to this equipment not expressly approved by Honeywell may void the user’s authority to
operate this equipment. (P/N 0-000-155-01)
Refer to the Trouble Function chart for sensor operation. IC Notice: This apparatus complies with Canadian Standards ICES-003 B and RSS-210. Approvals/listings:
Canada: Wiring methods shall be in accordance with CSA C22.1, Canadian Electrical Code, Part 1, Safety FCC IC cULus
Standard for Electrical Installations.

DT-7550C DUAL TEC® With Anti-Mask Motion Sensor Product Information


© 2004 Honeywell International Inc. • Honeywell, IntelliSense and DUAL TEC are registered trademarks of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved. Made in China

5-051-642-00 Rev E