IDX-OM-O004E-A

Initial release: February 2011


2th edition: November 2016

PRODUCT NAME

Refrigerated Air Dryer


MODEL

IDF15E1-10 (-A,C,K,L,M,R,S,T)
IDF15E1-20 (-A,C,K,L,M,R,T)

This manual is intended to explain the installation and operation of the product.
Only people who understand the basic operation of the product, or have basic
knowledge and ability to handle industrial machinery, are allowed to work on the
product.

Keep this manual available whenever necessary.

© 2016 SMC CORPORATION All Rights Reserved.


Foreword
Thank you for purchasing SMC’s refrigerant type air dryer (hereinafter referred to as the “product”).

For safety and long life of the product, be sure to read this Operation Manual (hereinafter referred to as the
“manual”) and clearly understand the contents.

● The instructions described in this manual must be followed in addition to ISO 4414*1) and JIS B 8370*2)
and other safety regulations.
*1) ISO4414: Pneumatic fluid power – Recommendations for the application of equipment to
transmission and control systems.
*2) JIS B 8370: General rules for pneumatic equipment.

● This manual is intended to explain the installation and operation of the product. Only people who
understand the basic operation of the product through this manual, or who install and operate industrial
machinery and have basic knowledge and ability to handle such equipment, are allowed to work on the
product.

● This manual and other documents attached to the product do not constitute a contract, and will not affect
any existing agreements or commitments.

● It is strictly prohibited to copy this manual entirely or partially for use by a third party without prior permission
from SMC.

Note: This manual is subject to change without prior notice.


Table of Contents
To Customers
Chapter i Safety Instructions
i.1 Warning: Before using this product ................................................ i - 1
i .1. 1 Danger, Warning and Caution..................................................................... i - 1
i.2 Hazard classification and locations of hazard labels ............... i - 2
i . 2. 1 Hazards ....................................................................................................... i - 3
i . 2. 2 Warning related to electricity....................................................................... i - 3
i . 2. 3 Warning related to high temperature .......................................................... i - 3
i . 2. 4 Warning related to rotating objects ............................................................. i - 3
i . 2. 5 Warning related to pneumatic circuit .......................................................... i - 4
i . 2. 6 Location of hazard label .............................................................................. i - 4
i . 2. 7 Caution related to refrigerant ...................................................................... i - 5
i . 2. 8 Caution related to handling ......................................................................... i - 6
i . 2. 9 Other labels................................................................................................. i - 6
i.3 Waste disposal .......................................................................................... i - 7
i.4 Limited warranty and Disclaimer / Compliance Requirements ...... i - 8
Chapter 1 Name and Function of Parts
1.1 Name and function of parts ................................................................ 1 - 1
Chapter 2 Transportation and installation
2.1 Transportation .......................................................................................... 2 - 1
2.2 Installation ................................................................................................. 2 - 2
2. 2. 1 Environment ............................................................................................... 2 - 2
2. 2. 2 Fixing of product ........................................................................................ 2 - 3
2. 2. 3 Pneumatic piping ....................................................................................... 2 - 4
2. 2. 4 Draining piping ........................................................................................... 2 - 4
2. 2. 5 Electric wiring ............................................................................................. 2 - 5
2.3 Reinstallation of the product ............................................................. 2 - 6
Chapter 3 Start and stop
3.1 Before starting ......................................................................................... 3 - 1
3.2 Start............................................................................................................... 3 - 1
3.3 Stop ............................................................................................................... 3 - 2
3.4 Precautions for restarting operation .............................................. 3 - 2
3.5 Check items after starting ................................................................... 3 - 2
3.6 Precautions for long-term non-operation ..................................... 3 - 2
Chapter 4 Checks and inspection
4.1 Daily check ................................................................................................ 4 - 1
4.2 Parts requiring regular maintenance .............................................. 4 - 1
4. 2. 1 Cleaning the condenser and aftercooler fins ............................................. 4 - 1
4. 2. 2 Service parts .............................................................................................. 4 - 1
4. 2. 3 Cleaning the auto drain strainer................................................................. 4 - 1
4. 2. 4 Replacement of case assembly ................................................................. 4 - 2
Chapter 5 Troubleshooting
5.1 Troubleshooting ...................................................................................... 5 - 1
Chapter 6 References
6.1 Specification table .................................................................................. 6 - 1
6.2 Refrigerant with GWP reference ....................................................... 6 - 1
6.3 Outer dimensions ................................................................................... 6 - 2
6.4 Electric wiring diagram ........................................................................ 6 - 2
6.5 Pneumatic and refrigerant circuits and their functions ........ 6 - 3
Chapter 7 Specification for Option A
7.1 Safety instructions ................................................................................. 7 - 1
7.2 Specifications ........................................................................................... 7 - 1
7.3 Air piping .................................................................................................... 7 - 1
Chapter 8 Specification for Option C
8.1 Safety instructions ................................................................................. 8 - 1
8.2 Specifications ........................................................................................... 8 - 1
8.3 Precautions for the installation and handling of the product ........ 8 - 1
Chapter 9 Specification for Option K
9.1 Safety instructions ................................................................................. 9 - 1
9.2 Specifications ........................................................................................... 9 - 1
Chapter 10 Specification for Option L
10 . 1 Safety instructions ............................................................................... 10 - 1
10 . 2 Specifications ......................................................................................... 10 - 1
10 . 3 Installation of heavy duty auto drain ............................................ 10 - 2
10 . 4 Maintenance ............................................................................................ 10 - 2
Chapter 11 Specification for Option M
11 . 1 Safety instructions ............................................................................... 11 - 1
11 . 2 Specifications ......................................................................................... 11 - 1
11 . 3 Installation of motor type auto drain ............................................ 11 - 2
11 . 4 Electric wiring diagram ...................................................................... 11 - 2
Chapter 12 Specification for Option R
12 . 1 Safety instructions ............................................................................... 12 - 1
12 . 2 Specifications ......................................................................................... 12 - 1
12 . 3 Power supply connection procedure ........................................... 12 - 1
12 . 4 Cautions for handling the GFCI ...................................................... 12 - 2
12 . 5 Electric wiring diagram ...................................................................... 12 - 2
Chapter 13 Specification for Option S
13 . 1 Safety instructions ............................................................................... 13 - 1
13 . 2 Specifications ......................................................................................... 13 - 1
13 . 3 Electric wiring diagram ...................................................................... 13 - 2
Chapter 14 Specification for Option T
14 . 1 Safety instructions ............................................................................... 14 - 1
14 . 2 Specifications ......................................................................................... 14 - 1
14 . 3 Remote operation ................................................................................. 14 - 1
14 . 4 How to connect the power and signal cable ............................. 14 - 2
14 . 5 Electric wiring diagram ...................................................................... 14 - 3
i Safety Instructions

i Safety Instructions
Before using the product be sure to read and understand all the
important actions highlighted in this manual.

i.1 Warning: Before using this product


This chapter is intended to specifically describe the safety related issues for handling the product. Read this
before handling the product.
- The product is designed to dehumidify compressed air. SMC does not take any responsibility for any
problems that may arise from using the product for other purposes.
- The product is operated at high voltage and contains components which become hot and rotate. If a
component needs to be replaced or repaired, contact a specialized vendor for parts and service.
All personnel who work with or around the product should read and understand the safety related
information in this manual carefully before starting work.
- This manual is not a comprehensive manual covering safety and health related issues. This should be
handled by a person in charge of safety training.
- All personnel who work with or around the product should have sufficient knowledge about the dangers
inherent to the product and be trained in safety measures.
- The safety manager is responsible for strictly observing safety standards, but responsibility in respect to
safety standards during daily work resides with each individual operator and maintenance personnel.
- The operator and maintenance personnel should consider work places and environments for each task
with due consideration of safety issues.
- It is necessary to undergo appropriate general safety training before being trained about this product.
Training without having sufficient knowledge about safety is very dangerous. Training must not be
conducted without consideration to safety.
- This manual must be kept available to the operator whenever necessary.
- If the product is subjected to a short power outage (including voltage sag), it may take a long time to start
operating normally or be unable to restart normally due to the protective equipment triggered after the
power is recovered. In that case, turn off the switch with lamp on the body once, on dryer panel and wait 3
minutes. After this step, turn on the switch to restart. Sudden restart of the product is possible after the
recovery of power, so be sure to turn off the switch with lamp when removing the cover panel of the
product.

i.1.1 Danger, Warning and Caution


The instructions given in this manual aim to assure the safe and correct operation of the product, and to
prevent injury of operators or damage to the product. These instructions are grouped into three categories,
"Danger", "Warning" and "Caution", which indicate the level of hazard, damage and also the degree of
emergency. All safety critical information should be carefully observed at all times.
DANGER, WARNING and CAUTION signs are in order according to severity (DANGER> WARNING>
CAUTION). The signs are explained on the following page.

Danger
"Danger" indicates a hazard with a high level of risk which will result in death or serious
injury if an operator performs incorrect handling during the operation and maintenance of
the product or does not follow the instructions necessary to avoid it.

i-1
i Safety Instructions

Warning
“Warning” indicates a hazard with a medium level of risk which will result in death or serious
injury if an operator does not follow the specified procedures during the operation or
maintenance of the product or does not follow the instructions necessary to avoid it.

Caution
“Caution” indicates a hazard of a low level of risk which will result in minor and moderate
injury or damage to product and equipment if an operator does not follow the specified
procedures during the operation and maintenance of the product or does not follow the
instructions to avoid it.

i.2 Hazard classification and locations of hazard labels


The product has various potential hazards and they are marked with warning labels. Read this section
before starting any work on the product.

Warning
- Only trained personnel should handle the product.
- Only people who have sufficient knowledge and experience about the product and its
accessories are allowed to carry out transportation, installation and maintenance work.
- Only maintenance personnel or people who have sufficient knowledge and experience are
allowed to open the cover panels of the product.

Warning
If any error occurs, take measures as instructed in this manual.

Warning
- If any error occurs, do not start operating the product.
- If any error occurs, immediately stop the product, and call for the maintenance personnel or
a person who has sufficient knowledge and experience about the product and its
accessories.

i-2
i Safety Instructions

i.2.1 Hazards
The hazards inherent to the product are as follows.

Warning related to electricity


The product is operated at a high voltage and can cause electrical shock internally. This risk is
indicated with the mark in addition to “Danger”, “Warning” and “Caution” on the product or in this
manual.

Warning related to heat


The product has surfaces that can reach high temperatures during operation, which may cause burns.
This risk is indicated with the mark in addition to “Danger”, “Warning” and “Caution” on the
product or in this manual.

Warning related to rotating objects


The product has parts that will rotate during operation, which may cause fingers to get caught and
injured. This risk is indicated with the mark in addition to “Danger”, “Warning” and “Caution” on the
product or in this manual.

i.2.2 Warning related to electricity


The product is operated at a high voltage and contains the power supply isolated by the cover panel.
Do not operate the product without cover panels fitted.
Only people who have sufficient knowledge and experience are allowed to perform work and
inspections in locations with the power supplied.

Warning
- Fully read and understand the contents of the hazard labels.
- Do not peel or rub off the hazard labels.
- Carefully confirm where the hazard labels are affixed.

i.2.3 Warning related to high temperature

Warning
The product has surfaces that can reach high temperatures during operation, and cause
burns by contact. Even after the power is turned off, there can still be residual heat in the
product, which may cause burns. Do not start work until the temperature of the surfaces
has fallen below 50oC.

i.2.4 Warning related to rotating objects

Warning
The product has parts that can rotate during operation, and cause injury by contact. Also,
the rotating parts might stop rotating temporarily and restart during operation. Do not
perform work during operation.

i-3
i Safety Instructions

i.2.5 Warning related to pneumatic circuit

Warning
Be sure to release compressed air from the product and ensure the internal pressure is
zero before replacing or cleaning the parts of the product. If the compressed air is left in the
product, when some part is loosened, it may cause sudden lurching or other unexpected
accidents.

i.2.6 Location of hazard label

Warning
- Fully read and understand the contents of the hazard labels.
- Do not peel or rub off the hazard labels.
- Carefully confirm where the hazard labels are affixed.

! WARNING 警告
1 Remove panels for maintenance only.
2 Never insert anything into product to ensure
safety.

! 3 Cut power prior to maintenance to prevent


electric shock.
4 Settle product to room temp.before main-
tenance toprevent burn or frostbite.
5 Ensure zero air pressure before replacing parts.

1 点検以外はパネルを取り外さないこと。
2 回転物があるので指、棒状の物を差し
込まないこと。
3 感電の恐れがあるので、点検の前には電源を
  切ること。
4 火傷の恐れがあるので、点検の前には装置を
  常温にすること。
5 部品交換の前には必ず、空気圧力を"0"に
  すること。

Front

i-4
i Safety Instructions

i.2.7 Caution related to refrigerant

Caution
- The product uses hydro-fluorocarbon type refrigerant (HFC).
- The product is categorized as category 1 under the fluorocarbon recovery and destruction
law in Japan.
The release of refrigerant into the atmosphere is banned by law. When the product is
serviced, the refrigerant must be recovered using “refrigerant recovery equipment” and
disposed of by a specialist disposal company. Only people who have sufficient knowledge
and experience about the product and its accessories are allowed to recover the
refrigerant.
- Only maintenance personnel or people who have sufficient knowledge and experience are
allowed to open the cover panels of the product.
- The type and necessary amount of HFC can be found on the specification label explained on
page 6 of Section i.

Front

i-5
i Safety Instructions

i.2.8 Caution related to handling

Warning
- Fully read and understand the contents of the hazard labels.
- Do not peel or rub off the hazard labels.
- Carefully confirm where the hazard labels are affixed.

! CAUTION 注 意
1 Read manual before operation.
2 Ensure vantilation and maintenance
space.
3 Keep water away from the product.
4 Secure In / Out connector with spanner
during piping.
5 Wait 3 minutes before restart.
6 Ensure Running Condition / Evaporating
Temp. in green zone.

1  ご 使 用 前 に 必 ず 取 扱 説 明 書 を 読 ん で くだ さ い 。
2  通 風 、 メ ン テ ナ ン ス ス ペ ー ス を 確 保 して
くだ さ い 。
3  雨 や 水 滴 が か か ら な い よ う に して くだ さ い 。
4  IN / O U T ポ ー ト を ス パ ナ で 固 定 し て
配 管 し て くだ さ い 。
5  再 起 動 は 運 転 停 止 3 分 後 に 行 っ て くだ さ い 。
6  R U N N IN G   C O N D IT IO N ・ 蒸 発 温 度 計 は
    グ リ ー ン 帯 で 使 用 し て くだ さい 。

Front

i.2.9 Other labels


Confirm the model and specifications described in the label.

i-6
i Safety Instructions

i.3 Waste disposal


When disposing of the product, recover the refrigerant and compressor oil contained in the refrigerant
circuit.

Caution
- The product uses hydro-fluorocarbon type refrigerant (HFC).
- The product is categorized as category 1 under the fluorocarbon recovery and destruction
law in Japan.
- The release of refrigerant into the atmosphere is banned by law. When the product is
serviced, the refrigerant must be recovered using “refrigerant recovery equipment” and
disposed of by a specialist disposal company.
- Only people who have sufficient knowledge and experience about the product and its
accessories are allowed to recover the refrigerant.
- Only maintenance personnel or people who have sufficient knowledge and experience are
allowed to open the cover panels of the product.
- The type and necessary amount of HFC can be found on the specification label.

Caution
- The disposal of the compressor oil must be in compliance with the bylaws or rules of the
local municipality.
- Do not mix the compressor oil with domestic waste for disposal. Also, the disposal of the
waste must only be conducted by specific facilities that are permitted for that purpose.
- Only people who have sufficient knowledge and experience about the product and its
accessories are allowed to recover the compressor oil.
- Only maintenance personnel or people who have sufficient knowledge and experience are
allowed to open the cover panels of the product. If anything is unclear, contact your local
supplier or SMC.

i-7
i Safety Instructions

i.4 Limited warranty and Disclaimer / Compliance Requirements


The product used subject to the following “Limited warranty and Disclaimer“ and “Compliance Requirements.
Read and accept them before using the product.

Limited warranty and Disclaimer

1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.
Also, the product may have specified durability, running distance or replacement parts. Please consult
your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility, a
replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage incurred
due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in
the specified catalog for the particular products.

Compliance Requirements

1. The use of SMC products with production equipment for the manufacture of weapons of mass
destruction (WMD) or other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are govemed by the relevant
security laws and regulation of the countries involved in the transaction. Prior to the shipment of a SMC
product of a SMC product to another country, assure that all local rules goveming that export are known
and followed.

Caution
The Product is provided use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange
specifications or a contact if necessary.
If anything is unclear, contact your nearest sales branch.

i-8
1. Name and Function of Parts

1 Name and Function of Parts

1.1 Name and function of parts


Ventilation air outlet
Hot air will be exhausted from
Switch with lamp condenser by fan. No obstacles
The switch to start and stop the product, shall be allowed to place on top
which will light up in green during operation. of it or even close the grille.

Evaporation thermometer
Displays the
evaporating temperature of
refrigerant.
Normally, it is in the green area.

Drain confirmation window


Front panel mounting screw From this confirmation window,
Another one is on the left side. confirm the discharge of drain.

Drain tube
Front Discharges drain.
Appearance

Auto drain
It is covered with insulator, which
should not be removed.

Front panel removal

1-1
1. Name and Function of Parts

IDF15E1-10 (100V AC specification)


Front
Air outlet piping
A port to exhaust air.

Ventilation air inlet


Air inlet piping Breathe in cooling air from
A port to supply air. this grille. Do not bung up
with wall and so on.

Earth screw
Connect the earth to
this screw.

Front panel mounting screw


Power supply cable Another one is on the right side.
Insert the plug to a
100V AC only outlet.
Rear

IDF15E1-20 (200V AC specification)

Rear panel
You can see the terminal block when you Front
remove this cover. Connect the power
cable through the membrane grommet.

L N PE( )

To the user’s machine


Terminal connecting screw: M3
Crimped terminal width: 6.5mm or less
Applicable electric wire: 1.25mm2 or more

Rubber grommet Rear


Power supply cable entry

1-2
2. Transportation and installation

2 Transportation and installation


Warning
- Use the product in an appropriate manner, and pay attention to safety, particularly physical
safety of operators, during the installation, operation, maintenance and checks of the product.
- When the product is used for a critical facility or equipment, prepare a spare product or
alternative machine in case of stoppage of the product due to the operation of the protective
equipment or the failure of the product itself.

Caution
- Only people who have sufficient knowledge and experience about the product and system are
allowed to perform the transportation, installation and maintenance of the product, including
dangerous work.

2.1 Transportation
Be sure to follow the instructions below when transporting the product.
- The product is filled with refrigerant. Transport it (by land, sea or air) in accordance with laws and
regulations specified.
- You should lift the product from the base surface with careful attention to prevent tipping over.
- Do not lay the product sideways, or you will damage the product.
- Do not suspend the product from the ceiling or hang from the wall.
- Do not transport the product with any part such as an air filter mounted on the fittings at the air inlet or
outlet port of the product. If it is unavoidable to transport the product with such a part mounted, support
the mounted part with a bracket to prevent the product from being affected by vibration during
transportation.
- Do not lift the product by holding the panel, fittings or piping.

Warning
The product is heavy and has potential dangers in transportation. Be sure to follow the
instructions above.
- To transport the product, a tool like a fork lift must be prepared.

2-1
2. Transportation and installation

2.2 Installation
2.2.1 Environment

(1) Do not use or store the product under the following conditions, as these may cause breakage of the
product as well as a failure of the product to operate.
• In an environment where the product will come into direct contact with rain, wind and snow or with a lot of
moisture (relative humidity 85% or more).
• In a location with a large quantity of dust.
• In a location containing flammable or explosive gases.
• In a location exposed to corrosive or flammable gases or solvent.
• In a location where the ambient temperature is outside the following ranges.
In operation: 2 to 40oC, In storage: 0 to 50°C (with no condensate in piping)
• In a location that is subjected to abrupt changes in temperature.
• In a location that is subjected to strong electromagnetic noise (intense electric field, intense magnetic field,
or surges)
• In a location that is subjected to static electricity, or conditions where static electricity can discharge to the
product.
• In a location that is subjected to strong high frequency radiation (microwaves)
• In a location that is subjected to potential lightning strikes.
• Locations by loading on vehicles, marine vessels, and so on.
• In a location with an altitude of 2,000 metres or higher.
• In a location where the product is affected by strong vibrations or impacts.
• Conditions where external force or weight is applied that could deform the product.
• In a location where there are obstacles blocking the ventilation ports of the product.
• In a location where the dryer is drawing in high temperature air that is discharged from an air compressor
or other dryers.

(2) Contact SMC beforehand and take special consideration of safety measures if the product is to be used in
any of the following conditions.
• Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to
direct sunlight.
• Installation on equipment in conjunction with atomic energy, railways, air navigation, shipping, vehicles,
medical treatment or recreation equipment, or equipment in contact with food and beverages,
emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other
applications unsuitable for the standard specifications described in the product catalog.
• An application which could have negative effects on people, property, or animals requiring special safety
analysis.

2-2
2. Transportation and installation

2.2.2 Fixing of product


Mount the product on a flat and stable floor with no vibrations.
- Refer to “6.2 Outer dimensions” on page 6-2 for dimensions.
- Use the foundation bolts to prevent the product from falling over.
The foundation bolts are available separately as a set.
- If there is not enough space around the ventilation ports of the product, loss of the original performance or
failure of the product can result. Follow the conditions shown in the figure below for installation.

4 5

2 3

Necessary maintenance space ∗1


1. Top 600mm or more
2. Front 600mm or more
3. Right side 600mm or more
4. Left side 600mm or more
5. Rear 600mm or more

∗ 1 The necessary maintenance space is to conduct maintenance and repairs when the product fails. Ensure
that sufficient space can be secured for repair.

2-3
2. Transportation and installation

2.2.3 Pneumatic piping


- Piping to the compressed air inlet and outlet should be connected with a union of fitting so that it can be
removed.
- Pressing the hexagonal fitting with screw wrench and so on, connect the air piping fittings to the body.
- When mounting any part such as an air filter on the fitting at the compressed air inlet or outlet port,
support the part to prevent excessive force from being applied to the product.
- Be careful not to transmit vibration resulting from the compressor.
- When the compressed air inlet temperature exceeds 50oC, install an aftercooler behind the air
compressor or decrease the temperature of the area where the air compressor is installed to keep it 50oC
or less.
- To prevent foreign matter such as dust from getting in the supply air to the product, flush the piping before
connecting. Dust or oil in the piping can cause cooling failure or other failures of the product. Install a
main line filter to the compressed air source to the product.
- Use a pipe capable of withstanding the specified operating pressure and temperature and connect so
that it will not have leakage.
- Be sure to install a bypass pipe to allow maintenance without stopping the air compressor.

We recommend the bypass piping sets that


we are selling separately as accessories.

The bypass piping sets


2.2.4 Draining piping
- The drain tube is equipped with a polyurethane tube of outside diameter 10mm. Release the draining end
of the tube to atmosphere to let condensate flow into a water outlet.
- Condensate will be drained regularly using compressed air pressure. Fix the draining end of the tube
firmly to prevent it from vibrating during draining.
- Ensure the drain tube does not rise up.
- Do not bend or crush the drain tube. When installing the product, take care not to place the product on the
drain tube.

Warning
- When draining, follow the user’s own procedure to keep operators safe. (E.g. Wear
protective goggles, apron and gloves to prevent contact with the drained condensate.)
- When oils can enter the drained condensate, waste water treatment is necessary.
Follow the bylaws or rules of the local municipality.

2-4
2. Transportation and installation

2.2.5 Electric wiring


Warning
Only qualified persons are allowed to wire the product.
- Before wiring, be sure to shut off the power supply. Never perform wiring work while the
product is energized.
- Ensure a stable power supply with no voltage surges.
- Ensure that an ground fault circuit interrupter with appropriate capacity for ground fault and
load is used in the power supply of the product to prevent electrical shock and burnout of the
compressor motor. See “6-1 Specification table” for details.
- Use a power supply suitable for the specifications of the product.
- Be sure to connect the ground connection.
- Grounding should never be connected to a water line, gas line or lightning rod.
- Multiple wiring is dangerous because it may lead to heat generation and cause a fire.
- Do not modify the electrical wiring of the power supply.
- For use in Europe, install a breaker compliant with applicable IEC standards to the power
supply of the prodct.

[Wiring of power supply]

There are two methods depends on model (specified power).

IDF15E1-10 (100V AC specification)


Insert the power plug into an outlet of AC100V.
∗ Be sure to install an ground fault circuit interrupter to the power supply. (To be prepared by the user.)
[Sensitivity of leak current: 30mA or less, Rated current: 10A]
Do not extend the power cable using power strip and so on.
That causes decrease of the voltage and the product cannot be operated.

IDF15E1-20 (200V AC specification)


Remove the terminal block cover or the rear cover in the rear of the product, and connect the power
(AC200V) to the terminal block.
∗ Be sure to install an ground fault circuit interrupter to the power supply. (To be prepared by the user.)
[Sensitivity of leak current: 30mA or less, Rated current: 10A]

Specifications of power supply cable


Prepare the following power supply cable.
Power supply cable: 1.25mm2(16AWG) or larger, Cable outside diameter Approx. 8 to 12mm, 3 cores
(including ground)
Approx. 0.1m is necessary to route the internal wiring of the product.

Power supply cable length


The power supply cable length from the product should be less than 30m.

2-5
2. Transportation and installation

Terminal block (refer to “1.1 Name and function of parts” for details).
Connect the power cable and the ground to the terminal block. The connection size is M3.
Be sure to use a round crimped terminal.
Applicable crimped terminal width: 6.5mm or less

[Wiring procedure]
1. Remove the terminal block cover or the rear panel.
2. Insert the cord through the rubber grommet and connect it to the terminal block (refer to the label on the
terminal block).
M3 screw tightening torque: 0.63 to 1Nm
During wiring work, do not touch other sections except terminal block.
3. Re-attach the cover or real panel after wiring is done.

2.3 Reinstallation of the product


Caution
- Only people who have sufficient knowledge and experience about the product and its
accessories are allowed to reinstall the product in a different location. Also, be sure to
follow the instructions below.
When moving the product to a different location or reinstalling it after it has been used (including trial run),
follow the whole procedure in Chapter 2 beforehand.

- Disconnection of power supply cable


Be sure to cut the facility power supply before disconnecting the power supply cable.

Warning
- Only people who have sufficient knowledge and experience are allowed to perform wiring.
- Before wiring, be sure to shut off the power supply. Never perform wiring work while the
product is energized.

Removal of pneumatic piping

Warning
- Only people who have sufficient knowledge and experience are allowed to perform piping work.
- Before removing piping, be sure to shut off the air supply and the product.
- Do not remove piping with any air pressure remaining internally.
Clean off any sealant debris after the piping is removed. If any sealant debris gets into the product during
reinstallation, it may lead to cooling failure or other product failures.

2-6
2. Transportation and installation

Residual compressed air pressure release procedure


1. Even while the dryer is removed, only when compressed air is needed, open the bypass piping valve.
2. Close the compressed air inlet and outlet valve.
3. Unscrew the front panel fixing screw (in 2 points) and remove the front panel with upholding it a little.
4. Open the residual pressure release cock of auto drain tube, and release compressed air pressure left
inside of the product. Refer to the figure at below.

Case Assembly

The remainder depressure cock.


∗ It opens when turning in the direction
of the arrow of figure.

2-7
3.Start and stop

3 Start and stop

Caution
Only people who have sufficient knowledge and experience about the product and its
accessories are allowed to start and stop the product.

3.1 Before Starting


Check the following items before performing a trial run of the product.
• Installation conditions
Check visually that the product is installed horizontally.
Ensure the product is fixed firmly by the anchor bolts.
Do not place any heavy object on the product, or apply excessive force to the product by the external
piping.
• Connection of cables
Check the power supply and ground are correctly connected.
• Drain tube
Check proper connection of the drain tube.
• Pneumatic piping
Check proper connection of pneumatic piping. Ensure the valves at the inlet and outlet and bypass of the
product are completely closed.

3.2 Start
Start the product by the following procedure.
1) Turn on the main power supply. Then, turn on the switch with lamp.
2) The lamp will light up and the cooling fan will start turning a while later, and hot air will blow out from
the exhaust port.
3) Open the valve at the inlet and outlet of the product slowly and fully. Ensure the bypass valve is
completely closed. Check there is no air leakage.
4) The cooling fan keeps starting and stopping depending on the compressed air and ambient
temperature conditions, but the compressor keeps operating continuously, and the evaporation
thermometer stays within the green area. If the evaporation thermometer exceeds the green area
(indicates a higher temperature), refer to “Chapter 5 Troubleshooting”.
5) A while after the compressed air starts being supplied, the drain tube will drain condensate
automatically.
6) Keep operation in that condition.

3-1
3.Start and stop

Caution
- Frequently turning on and off the switch can cause failure.
- Since the auto drain of the product is designed in such a way that the valve closes at
0.05MPa or higher (N.C. type), air will blow out from the drain port when the pressure
increases. Therefore, if the air compressor has a small air delivery, the pressure may not
be sufficient.

3.3 Stop
1) Turn off the switch with lamp.
2) The lamp will go off and operation will stop.

3.4 Precautions for restarting operation


- Allow at least 3 minutes before restarting the product. If the product is restarted within 3 minutes after
being stopped, the protection circuit will be activated, operating light will turn off and the dryer will not be
activated.
If operation cannot be restarted, refer to “Chapter 5 Troubleshooting” to solve it.

3.5 Check items after starting


Check the following items when starting the product. Immediately stop the operation in the event of failure.
Turn off the switch with lamp and shut off the breaker of the main power supply.
- There is no compressed air leakage.
- The pressure, temperature, flow rate and ambient temperature of the compressed air are within the
specified range.
- Condensate is coming out from the drain tube.
- The evaporation thermometer is in the green area.
- There is no abnormal sound, vibration or odor from the product.

3.6 Precautions for long-term non-operation


If the product will not be operated for 24 hours, for example at the weekend, turn off the Switch with lamp
or power supply, for energy saving and safety. It is also recommended to release the pressure inside the
compressed air piping and this air dryer.

3-2
4. Checks and Inspection

4 Checks and inspection


4.1 Daily check
Check the following items daily. Immediately stop the operation in the event of failure, and refer to “Chapter
5 Troubleshooting” to solve it.
- There is no compressed air leakage.
- The START lamp lights up during operation.
- Condensate comes out of the drain tube during operation.
- The evaporation thermometer is in the green area during operation with the compressed air supplied.
- The evaporation thermometer indicates a temperature approx. 3 to 10oC lower than the ambient
temperature when operation is stopped and no compressed air supplied.
- There is no abnormal sound or vibration.
- There is no abnormal odor or smoke.

4.2 Parts requiring regular maintenance


4.2.1 Cleaning the condenser and aftercooler fins
To eliminate dust at the ventilation port (suction port), apply an electrical vacuum or air blow once every
month. Wear protective goggles and a mask to prevent dust from entering the eyes or throat during air
blow.

4.2.2 Service parts


It is recommended to replace the following parts regularly. The interval shown in this operation manual
depend on the operating conditions (ambient temperature, installation environment, etc.), so that they are
for reference.
Table 1. List of parts to be replaced regularly
Description Tecommended replacement interval
Pressure switch One Million times
Fan motor 20,000 hours
Magnetic Contactor, Magnetic Switch (Note) One Million times
∗Note) If it is mounted by option ”T” (With terminal block for power supply, run, alarm signal and remote
operation) or special order.

4.2.3 Cleaning the auto drain strainer


Remove dust from the auto drain strainer once a month. Use a neutral detergent for cleaning. Also, if
the auto drain becomes heavily polluted replace it with a new one and shorten the next cleaning interval.
Part number of the auto drain strainer
Part no. Description Qty.
IDF-S0002 Auto drain strainer 1

4-1
4. Checks and Inspection

4.2.4 Replacement of case assembly


Replace the case assembly with a new one if after cleaning it the auto drain continues operating failure.
Part number
Part no. Description Qty.
AD48 Auto drain 1

Warning
- Maintenance of the air dryer should only be carried out by someone with sufficient knowledge and
experience of air dryers and related equipment.
- Before carrying out maintenance, the important warnings in this manual must be thoroughly read and
understood.

Danger
- When replacing or cleaning parts of the air dryer, be sure to remove the compressed air pressure
inside the air dryer to “0”. Never remove the case assembly when the air dryer is operated or air
pressure remains inside. It is extremely dangerous if compressed air pressure remains inside the air
dryer, as parts may come flying off at speed when loosened, or other unexpected accidents.
- This product has parts that become hot during operation and a power supply with high voltage applied.
There is a risk of burns due to heat or electrification by high voltage. Even when operation is shut
down after switching off the air dryer’s illuminated light, there are also charging lines. When working
on the charged sections, be sure to switch off the earth leakage breaker installed before starting work.
- As some parts of the air dryer will remain hot, there is a risk of burns due to residual heat after the
power is switched off. So do not carry out replacement work until the temperature of these parts has
fallen to 50oC or less. Wait for about 10 to 15 minutes as a guide.
- When carrying out maintenance work on the auto drain strainer and auto drain, there is a risk of
touching the drain fluid during work. Please follow the safety procedure for operators specified by
customer. (Example: carry out work wearing safety glasses, apron and gloves to prevent discharged
fluid from touching the human body.)
- Use neutral detergent solution to clean parts such as the auto drain strainer and auto drain. Never use
solvent such as thinner.
- When removing the outer casing panel or case assembly of the auto drain, wear gloves to prevent
injuries.

[How to clean and replace the auto drain/strainer]


When carrying out maintenance work on the auto drain and auto drain strainer, please follow the steps below.

- Turn off the switch with lamp.


- Disconnect the earth leakage breaker at the power supply or unplug the power plug from the socket.
- Fully close the inlet and outlet valves. Only open the bypass when compressed air is required during work.
- Only the point that is necessary for work please remove a decoration panel.

4-2
4. Checks and Inspection

- Open the residual pressure release cock


at the drain tube connection port to Lock
release air and drain fluid left in the product. button
(Leave the drain tube connected and hold
Residual
it with hand so that it does not get twisted.) pressure
release
- Because drain may be given by air pressure left cock
Drain tube
in a product like a careful. Drain tube O S

- Remove the drain tube. release bush Open Close


Pull out the tube while pushing up the drain tube release bush.

- Hold the case assembly lightly and pull down Mark


the lock button with thumb.
Then, turn the case assembly to the left (or right)
Lock button
to 45oto align the marks.
Release your thumb from the lock button and Turn to 45o
(right or left)
slowly pull down the case assembly (vertically)
to remove it. Pull it down
slowly.

- Remove the auto drain strainer and clean it. Drain separator
Take care not to cut your hand with the sharp edges body

of the strainer.
- Pour solution of neutral detergent into the case assembly Auto drain
strainer
and shake it well to clean.
- Check the case O-ring for damage such as scratches,
twisting or foreign particles attached to it. O-ring
Then, apply grease thinly and fit it in the groove in the
case assembly.
- Fit the auto drain strainer to the case assembly and fit it into the
drain separator body.
Turn it untill the lock button clicks. Case assembly
CAUTION
- Try to turn the case assembly lightly and check that it does not turn.
Check that air

If it turns, start with fitting the case assembly to the body again. pressure is zero
before servicing.

- Close the residual pressure release cock and mount the


drain tube and front panel as they were.
- When reapplying compressed air to the air dryer, first open the
valve on the inlet side slowly.
Check for compressed air leak and if everything is all right, open the valve on the outlet side.
- If the auto drain strainer or case assembly is damaged or very dirty, replace it with a new one.

4-3
5. Troubleshooting

5 Troubleshooting
5.1 Troubleshooting
If any error is found in the product, investigate the following points. If the error cannot be solved, turn off the
power supply and contact your local supplier or SMC sales representative.
Trouble Possible cause Remedy
Although the The power supply cable has been - Reconnect it firmly.
switch with lamp loosened or disconnected.
is turned on, the The ground fault circuit Check the capacity of the ground fault circuit interrupter.
lamp does not interrupter is not turned on. - Check the product was not restarted within 3 minutes after
light up and the being stopped.
product does not - Turn on the ground fault circuit interrupter and try to
start operating. operate.
If the ground fault circuit interrupter turns back off, the
insulation failure of the product is suspected. Turn off the
power supply and contact SMC.
Running lamp The product is installed in an - Improve ventilation condition and reduce the ambient
extinguishes inappropriate location. temperature as much as possible.
Ambient temperature is excessive.
and compressor
The ventilation port is obstructed - Keep the product 600mm or more away from the
stops during by a wall or clogged with dust. surrounding walls.
operation but - Clean the ventilation ports once every month.
resumes normal The compressed air temperature is - Improve the ventilation in the location where the air
operation too high. compressor is installed, or decrease the ambient
illuminating the temperature to allow the discharge air temperature of the
lamp after air compressor to go down.
aperiod of time. - Install an aftercooler after the air compressor to reduce the
temperature.
The fluctuation of the power supply - Install a power supply transformer or use a different power
voltage is too large. supply to provide appropriate voltage.
- The fluctuation of the power supply voltage should be kept
within +/-10% of the rated voltage.
The evaporation The product is installed in an - Improve ventilation condition and reduce the ambient
thermometer is inappropriate location. temperature as much as possible.
over the green Ambient temperature is excessive.
area without hot The ventilation port is obstructed - Keep the product 600mm or more away from the
air coming from by a wall or clogged with dust. surrounding walls.
the ventilation - Clean the ventilation ports once every month.
port (exhaust The compressed air temperature is - Improve the ventilation in the location where the air
port). excessive. compressor is installed, or decrease the ambient
(The compressor temperature to allow the discharge air temperature of the
for refrigeration air compressor to go down.
has stopped with I t ll a power
ft supply
l fttransformer
th i or use a different
t d power
th
The fluctuation of the power supply - Install
the lamp lit up.
voltage is too large. supply to provide appropriate voltage.
- The fluctuation of the power supply voltage should be kept
within +/-10% of the rated voltage.
The built-in overload relay of the - Check the product was not restarted within 3 minutes after
compressor for refrigeration has being stopped.
started.

5-1
5. Troubleshooting

Trouble Possible cause Remedy


The evaporation The product is installed in an - Improve ventilation condition and reduce the ambient
thermometer is inappropriate location. temperature as much as possible.
over the green Ambient temperature is excessive.
area with hot air The ventilation port is obstructed - Keep the product 600mm or more away from the
coming from the by a wall or clogged with dust. surrounding walls.
ventilation port - Clean the ventilation ports once every month.
(exhaust port). The compressed air temperature - Improve the ventilation in the location where the air
is excessive. compressor is installed, or decrease the ambient
temperature to allow the discharge air temperature of the
air compressor to go down.
- Install an aftercooler after the air compressor to reduce the
temperature.
Moisture is The bypass valve is open. - Be sure to fully close the bypass valve.
generated at the Condensate is not drained from - Check the draining piping is not used in an upward direction
downstream of the auto drain. nor bent.
the compressed - Check the auto drain.
air line. - Check the auto drain strainer.
The piping of a different system - Install another air dryer (this product) in that system.
without an air dryer joins the piping - Keep the two systems separate.
after the product.
The compressed The valves at the inlet and outlet of - Be sure to fully open the valves at the inlet and outlet of the
air pressure is the piping of the product are not product.
too large. fully opened.
The air filter, etc. installed in the - Replace the element of the air filter.
compressed air piping has got (Follow the Operation Manual of the equipment.)
clogged.

5-2
6. Reference

6 Reference
6.1 Specification table

Model
IDF15E1-10 IDF15E1-20
Item
Fluid Compressed air
Operatin
g range

o
Inlet air temperature C 5 to 50
Inlet air pressure MPa 0.15 to 1.0
o
Ambient temperature (humidity) C 2 to 40 (Relative humidity 85% or less)
Standard conditions 50Hz 2.8
Rated specifications

Air flow (ANR)


Note 1)
60Hz 3.1
capacity
3
m /min Air compressor suction 50Hz 2.9
Note 2)
condition 60Hz 3.2
Inlet air pressure MPa 0.7
o
Inlet air temperature C 55
o
Ambient temperature C 32
o
Outlet dew point C 10
1 phase AC100V (50Hz) 1 phase AC200V (50Hz)
specifications

Power supply voltage (frequency)


AC100,110V (60Hz) Note 3) AC200,220V (60Hz) Note 3)
Electric

Power consumption (50/60Hz) W 420 / 480


Running current (50/60Hz) A 4.3 / 4.6 3.4 / 3.1
Note 4)
Applicable ground fault circuit interrupter capacity A 10
Refrigerant R134a (HFC)
Quantity of refrigerant g 350±10
Auto drain Float type (N.O)
Port size Rc1
Weight kg 46
Coating color Panel: Urban white 1 / Base: Urban gray 2
Applicable air compressor output (referential) kW 15

Note 1) Air flow capacity under the standard condition (ANR) [20oC atmospheric pressure and 65% relative humidity].
Note 2) Air flow capacity calculated for atmospheric condition [32oC, atmospheric pressure]
Note 3) When short period power shortage (including instantly recovered shortage) is recovered, it may take a
longer starting period than usual starting or may not start due to the protective devices.
Note 4) Use an ground fault circuit interrupter with sensitivity of 30mA.

6.2 Refrigerant with GWP reference

Note 1) This product is hermetically sealed and contains fluorinated greenhouse gases.
Note 2) See specification table for refrigerant used in the product.

6-1
6. Reference

6.3 Outer dimensions


[ID F1 5E1] Unit: mm

603 54 41
300 VENTILATION 16
AIR OUTLET

SWITCH AIR OUTLET


WITH LAMP R C1
EVAPORATION AIR INLET
THERMOMETER R C1

87
DRAIN SEPARATOR
578

VENTILATION VENTILATION
[AC200V]

396
TERMINAL BLOCK
DRAIN TUBE
(O.D.10
LENGTH:0.8m)

43
270 15
314 4xφ13 380 101 258

[AC100V]
[AC200V]
POWER SUPPLY CORD
POWER SUPPLY CABLE ENTRY (φ17)
(LENGTH:1.9m)
RUBBER GROMMET

6.4 Electric wiring diagram


[ ID F15 E1 -1 0]

PC

Symbol Description
ILS CM Refrigerating compressor
OLR PTC FM Fan motor
OLR Overload relay
ILS Switch with lamp
CM PTC PTC Starter
C01 C02
PRS Pressure switch
PC Power supply cable
C01 Capacitor for running refrigerating compressor
C11 C02 Capacitor for starting refrigerating compressor
FM
PRS C11 Capacitor for running fan motor

6-2
6. Reference

[ ID F15 E1 -2 0]

L N PE
TB

ILS Symbol Description


CM Refrigerating compressor
OLR PTC FM Fan motor
OLR Overload relay
CM ILS Switch with lamp
PTC PTC Starter
PRS Pressure switch
TB Terminal block
C11 C11 Capacitor for running fan motor
FM
PRS
P

6.5 Pneumatic and refrigerant circuits and their functions


Compressed Heat exchange
air inlet
Compressed
air outlet

Evaporation
thermometer
Drain separator
Drain outlet
Capacity Regulating
valve

Capillary tube

Refrigerating Press.switch
Compressor Condenser Fan motor

Pneumatic circuit
Humid hot air entering air dryer is cooled in the cooler. At this time, the condensate is separated
from the air by the drain separator and automatically discharged. The dry air is heated by the
re-heater until it gets about the same temperature as that of ambient air. It is then discharged from
air dryer outlet.

Refrigerant circuit
The HFC gas contained in the refrigerant circuit is compressed by the compressor, and cooled and
liquefied by the condenser. When passing through the capillary tube, the HFC gas is regulated and
its temperature decreases. While passing through the cooler part, it evaporates rapidly, taking the
heat from the compressed air, and is sucked in by the compressor. The capacity regulating valve
opens when the compressed air has been cooled sufficiently, and prevents condensed water from
being frozen by excessive cooling.

6-3
7. Specification for Option A

7 Specification for Option A


7.1 Safety instructions
When handling the product, take care to the following precautions.

Warning
Shut off the power supply when removing the panel for maintenance work, etc. The product
has a fan(s) and could cause serious danger to operators.

7.2 Specifications
Cool outlet air (10oC) can be supplied. The air flow with this option is smaller than that of the standard
dryer.

7.3 Air piping


Since cool air comes out from an outlet of air dryers, carefully attach thermal insulation to the piping at air
outlet and keep the piping length as short as possible in order to prevent condensation on the outlet piping
and temperature increase on the outlet due to ambient temperature.

7.4 Air flow capacity

Model IDF15E1-10/20-A
50Hz 1.2
Air flow capacity m3/min(ANR) Note1)

60Hz 1.3
o
Outlet air temp. C 10

Note1) The data for ANR is referring to the conditions of 20°C, 1atm. pressure & relative humidity of 65%.
Note2) The conditions are the same as the ones for standard models other than air flow capacity.

7- 1
8. Specification for Option C

8 Specification for Option C


8.1 Safety instructions
When handling the product, take care to the following precautions.

Warning
Shut off the power supply when removing the panel for maintenance work, etc. The product
has a fan(s) and could cause serious danger to operators.

8.2 Specifications
The surface of copper tube is painted with a special epoxy resin for the rust proofing. The parts covered
with aluminum fins and insulations are not painted.

8.3 Precautions for the installation and handling of the product


1) The surface of cooper tube is painted with a special epoxy to improve the rust proof effect from
corrosive gas, but it is not perfect rust proof. Therefore, avoid installing the product in the place
exposed to corrosive gas as much as possible.

2) If any of the painted surfaces of copper tube is damaged, such as when the panels are removed for
maintenance, the effect of its rust proofing painting is lost. Do not give damage any painted surfaces of
copper tube.

8- 1
9. Specification for Option K

9 Specification for Option K


9.1 Safety instructions
When handling the product, take care to the following precautions.

Warning
- Do not remove the auto drain with the air pressure remaining internally. If the compressed
air is left in the product, when some part is loosened, it may cause sudden lurching or
other unexpected accidents.
- When removing the panel, wear protective gloves to prevent injuries.
- There is a risk of touching drained waste liquid during replacement.
When draining, follow the user’s own procedure to keep operators safe. (E.g. Wear
protective goggles, apron and gloves to prevent contact with the drained condensate.)
- When oils can enter the drained condensate, waste water treatment is necessary. Follow the
bylaws or rules of the local municipality for disposal.

9.2 Specifications
The maximum operating pressure 1.6MPa. A metal bowl with a level gauge which can confirm the water
label is used for auto drain.
AD48-8-X2110

Insulation
Fluid level indicator

KQ2H10-02S
Drain Port
φ10

Model
IDF15E1-10-K IDF15E1-20-K
Item
Part number Note1) IDF-S0086

Auto drain type Floating type


Auto drain valve type N.O. (normally opened: Released without pressurization)

Note1) The above part number does not include the auto drain strainer. If the strainer needs to be
replaced, order it.
Part no. Description Qty.
IDF-S0002 Auto drain strainer 1

9- 1
10. Specification for Option L

10 Specification for Option L


10.1 Safety instructions
When handling the product, take care to the following precautions.

Warning
- Do not remove the auto drain with the air pressure remaining internally. If the compressed
air is left in the product, when some part is loosened, it may cause sudden lurching or
other unexpected accidents.
- When removing the panel, wear protective gloves to prevent injuries.
- There is a risk of touching drained waste liquid during replacement.
When draining, follow the user’s own procedure to keep operators safe. (E.g. Wear
protective goggles, apron and gloves to prevent contact with the drained condensate.)
- When oils can enter the drained condensate, waste water treatment is necessary. Follow the
bylaws or rules of the local municipality for disposal.

10.2 Specifications
The maximum operating pressure 1.6MPa. The float type auto drain used in the standard air dryer is
replaced with a heavy duty auto drain (ADH4000-04). The customer is required to mount the auto drain to
the air dryer.

Model
IDF15E1-10-L IDF15E1-20-L
Item
Auto drain type Floating type
N.O.
Auto drain valve type (normally opened: Released without
pressurization)
Working pressure range 0.05 to 1.6MPa
400cc/min
Max. drain discharge
(Pressure 0.7MPa, the case of water)

Note) Use for air compressor with flow more than 50L/min (ANR).

Parts shown in are accessories attached to the unit.

10- 1
10. Specification for Option L

10.3 Installation of heavy duty auto drain


1) Hold the hexagon-head part (width across flats: 32) at port Rc1/2 of the air dryer with spanner.
Then install nipple, ball valve (width across flats: 25).
Note 1) Put up the seal tape or the sealant to the nipple. Tightening torque: 28 to 30Nm
2) Hold the ball valve with the spanner. Then install a nipple and a heavy duty auto drain.
Install with “out port" down in a vertical position. Inclination from the vertical line should be less than 5°.
3) Install one-touch fitting (width across flats: 22) to drain port (width across flats: 27) and the drain tube.

Nipple
Heavy duty auto drain

(Pilot exhaust port)

Ball valve

(Flush button)
(Bleed valve)

10.4 Maintenance
1) As a preventive maintenance, press the flush button of the heavy-duty auto drain regularly to clean the
discharge valve (for flushing).
2) The pilot exhaust of the heavy-duty auto drain is at the position shown in the figure. Do not close the
exhaust port. Also, clean the exhaust port to prevent it from getting blocked by dust.
3) Close the ball valve before removing the heavy duty auto drain and open the bleed valve or push the
flushing button and confirm air pressure is released.

Pilot exhaust port

Flush button
Body
Bleed valve

close open

10- 2
11. Specification for Option M

11 Specification for Option M


11.1 Safety instructions
When handling the product, take care to the following precautions.

Warning
- Do not remove the auto drain with the air pressure remaining internally. If the compressed
air is left in the product, when some part is loosened, it may cause sudden lurching or
other unexpected accidents.
- When removing the panel, wear protective gloves to prevent injuries.
- There is a risk of touching drained waste liquid during replacement.
When draining, follow the user’s own procedure to keep operators safe. (E.g. Wear
protective goggles, apron and gloves to prevent contact with the drained condensate.)
- When oils can enter the drained condensate, waste water treatment is necessary. Follow the
bylaws or rules of the local municipality for disposal.

Warning
Only qualified persons are allowed to wire the product.
- Use a power supply suitable for the specifications of the product.
- Be sure to connect the ground connection.
- Grounding should never be connected to a water line, gas line or lightning rod.
- Multiple wiring is dangerous because it may lead to heat generation and cause a fire.
- Do not modify the electrical wiring of the power supply.

11.2 Specifications
The float type auto drain used in the standard air dryer is replaced with a motor type auto drain (ADM200).
The customer is required to mount the auto drain to the air dryer.

Model
IDF15E1-10-M IDF15E1-20-M
Item
Part No. IDF-S0087 IDF-S0090
Max. pressure 1.0MPa
Operating cycle Once every minute

Operating time 2 seconds/cycle


Power supply
AC100V (50/60Hz) AC200V (50/60Hz)
voltage of dryer
Power consumption 4W

Parts shown in are accessories attached to the unit.

11- 1
11. Specification for Option M

11.3 Installation of motor type auto drain


1) Hold the hexagon-head part (width across flats: 32) at port Rc1/2 of the air dryer with spanner.
Then install nipple, ball valve (width across flats: 25).
Note 1) Put up the seal tape or the sealant to the nipple. Torque R1/2: 28 to 30Nm
2) Hold the ball valve with the spanner. Then install a nipple and a motor type auto drain.
Install with “out port" down in a vertical position. Inclination from the vertical line should be less than 5°.
3) Install one-touch fitting (width across flats: 17) to drain port (width across flats: 30) and the drain tube.
4) Connect the 2 electric cables coming out from the auto drain with the two electric cables from the dryer
unit. Insert the drip-proof connector to the deepest part.

11.4 Electric wiring diagram


IDF15E1-10-M IDF15E1-20-M

PC L N PE
TB

ILS
ILS
OLR PTC OLR PTC

CM
CM
C01 C02

C11
C11 FM
FM PRS
PRS
P
P MOV
MOV

Symbol Description Symbol Description


CM Refrigerating compressor PC Power supply cable
FM Fan motor TB Terminal block
OLR Overload relay C01 Capacitor for running refrigerating compressor
ILS Switch with lamp C02 Capacitor for starting refrigerating compressor
PTC PTC Starter C11 Capacitor for running fan motor
PRS Pressure switch MOV Motor type auto drain

11- 2
12. Specification for Option R

12 Specification for Option R


12.1 Safety instructions
When handling the product, take care to the following precautions.

Warning
Only qualified persons are allowed to wire the product.
- Before wiring, be sure to shut off the power supply. Never perform wiring work while the
product is energized.
- Ensure a stable power supply with no voltage surges.
- Use a power supply suitable for the specifications of the product.
- Be sure to connect the ground connection.
- Grounding should never be connected to a water line, gas line or lightning rod.
- Multiple wiring is dangerous because it may lead to heat generation and cause a fire.
- Do not modify the electrical wiring of the power supply.

12.2 Specifications
Customer should connect power cords at primary side of ground fault circuit interrupter, which is different
from standard such as plug-in type (AC100V) or terminal block type (AC200V). The ground fault circuit
interrupter is located at the rear side (air inlet and outlet side).

Model
IDF15E1-10-R IDF15E1-20-R
Item
Current rating (A) 10
Sensitivity current (mA) 30

12.3 Power supply connection procedure


1) Take off the rear panel.
2) Insert the power cable prepared by the customer into the
power code fixture and bring the power cable near the
terminal base through the base hole.

Ground Fault
To the user’s machine
Terminal connecting screw: M5 Circuit Interrupter
Connector width: 9.5mm or less
Applicable electrical wire: 1.25mm2 or more

L N
L ,N: Power supply

Ground fault display button (white)

test button (gray)

12- 1
12. Specification for Option R

3) Connect the power cable to the terminal of the GFCI.


4) Connect the ground line.
- AC100V: Connect the ground line to M4 screw on the left side of the GFCI (with the name plate).
- AC200V: Connect it to the terminal block (ground connection thread: M3)
5) Mount the rear panel.

12.4 Cautions for handling the GFCI


1) When the breaker is tripped, cut off the power supply and contact the nearest sales distributor or SMC
sales.
- With the Ground fault display button (white) released → Current leakage
- With the Ground fault display button (white) pressed → Over current
2) Check the operation once a month by pressing the test button (gray) with the breaker on and Switch with
Lamp off.

12.5 Electric wiring diagram


IDF15E1-10-R IDF15E1-20-R
L N L N

GFCI GFCI
PE
TB
ILS
ILS
OLR PTC
OLR PTC

CM CM
C01 C02

C11 C11
FM FM
PRS PRS
P P

Symbol Description Symbol Description


CM Refrigerating compressor PC Power supply cable
FM Fan motor TB Terminal block
OLR Overload relay C01 Capacitor for running refrigerating compressor
ILS Switch with lamp C02 Capacitor for starting refrigerating compressor
PTC PTC Starter C11 Capacitor for running fan motor
PRS Pressure switch GFCI Ground fault circuit interrupter

12- 2
13. Specification for Option S

13 Specification for Option S


13.1 Safety instructions
When handling the product, take care to the following precautions.

Warning
Only qualified persons are allowed to wire the product.
- Before wiring, be sure to shut off the power supply. Never perform wiring work while the
product is energized.
- Ensure a stable power supply with no voltage surges.
- Use a power supply suitable for the specifications of the product.
- Be sure to connect the ground connection.
- Grounding should never be connected to a water line, gas line or lightning rod.
- Multiple wiring is dangerous because it may lead to heat generation and cause a fire.
- Do not modify the electrical wiring of the power supply.

13.2 Specifications
The option allows the connection of a power cable to a terminal block.
IDF15E1-20 is equipped as standard.

Rear panel
You can see the terminal block when you Front
remove this cover. Connect the power
cable through the membrane grommet.

L N PE( )

To the user’s machine


Terminal connecting screw: M3
Crimped terminal width: 6.5mm or less
Applicable electric wire: 1.25mm2 or more

Rubber grommet
Power supply cable entry

13- 1
13. Specification for Option S

13.3 Electric wiring diagram


IDF15E-10-S

L N PE
TB
Symbol Description
CM Refrigerating compressor
ILS FM Fan motor

OLR OLR Overload relay


PTC
ILS Switch with lamp
PTC PTC Starter
CM PRS Pressure switch
C01 C02 TB Terminal block
C01 Capacitor for running refrigerating compressor
C02 Capacitor for starting refrigerating compressor
C11
FM C11 Capacitor for running fan motor
PRS
P

13- 2
14. Specification for Option T

14 Specification for Option T


14.1 Safety instructions
When handling the product, take care to the following precautions.

Warning
Only qualified persons are allowed to wire the product.
- Before wiring, be sure to shut off the power supply. Never perform wiring work while the
product is energized.
- Ensure a stable power supply with no voltage surges.
- Ensure that an ground fault circuit interrupter with appropriate capacity for ground fault and
load is used in the power supply of the product to prevent electrical shock and burnout of the
compressor motor.
- Use a power supply suitable for the specifications of the product.
- Be sure to connect the ground connection.
- Grounding should never be connected to a water line, gas line or lightning rod.
- Multiple wiring is dangerous because it may lead to heat generation and cause a fire.
- Do not modify the electrical wiring of the power supply.
- For use in Europe, install a breaker compliant with applicable IEC standards to the power
supply of the prodct.

14.2 Specifications
This option installs a terminal block that has outputs for the operation and failure signals.
- The operation and failure signals are no voltage contact style
Operation・・・・・When the product is operating; Close
Failure・・・When the product stops due to failure; Close
- Contact capacity
AC200V, 1A
Minimum current for signal: AC10mA, DC30mA

14.3 Remote operation


- When a remote operation is used, the switch with lamp should remain on; turn the power supply on and
off to start and stop operations.
- Wait 3 minutes before restart after the air dryer is stopped for both manual and remote operation.
Restart within 3 minutes will cause the protective equipment (overload relay) to move and the operation
will be prevented.
Also, the frequency of starting and stopping should be 5 times per hour or less (to prevent the motor
failed.)

14- 1
14. Specification for Option T

14.4 How to connect the power and signal cable

Front

Rear panel
You can see the terminal block when you
remove this cover.

L N PE 1 2 3

L,N:Power supply Failure


PE:Ground Operation

To the user’s machine


Terminal connecting screw: M3
Crimped terminal width: 6.5mm or less
Applicable electric wire: 1.25mm2 or more

Rubber grommet Rubber grommet


Power supply cable entry Signal cable outlet

Connect the power cable and signal cable in the following procedures.
1) Take off the rear panel.
2) Insert the power cable prepared by the customer into the power cord inlet (with rubber grommet) and
bring the power cable near the terminal block through the base hole.
3) Connect the power cable to the terminal.
4) Insert the signal cable prepared by the customer into the signal cord inlet (with rubber grommet) and
bring the signal cable near the terminal block.
5) Connect the signal cable to the each terminal.
6) Put back the rear panel.

14- 2
14. Specification for Option T

14.5 Electric wiring diagram


IDF15E1-10-T IDF15E1-20-T
Operation Failure Operation Failure
L N PE 1 2 3 L N PE 1 2 3
TB TB

MC TDR MC TDR
ILS ILS

MC TDR MC TDR

OLR PTC OLR PTC


MC MC

CM
CM
C01 C02
MC
MC
C11
C11 FM
FM PRS
PRS
P
P
TDR MC TDR MC

Symbol Description Symbol Description


CM Refrigerating compressor TB Terminal block
FM Fan motor C01 Capacitor for running refrigerating compressor
OLR Overload relay C02 Capacitor for starting refrigerating compressor
ILS Switch with lamp C11 Capacitor for running fan motor
PTC PTC Starter TDR Time delay relay
PRS Pressure switch MC Magnetic contactor

14- 3