PP Power Systems Brochure Data
PP Power Systems Brochure Data
PP Power Systems Brochure Data
E FFICIE NT POWE R
GE NE R ATION
POWER BOILERS
TAB LE OF CONTE NTS
SELECTED
REFERENCES
References and current
projects from ANDRITZ in
the field of air pollution
control technologies.
2 3
Fluidized bed technology - BFB TECHNOLOGY
In a BFB unit, fuels are thoroughly mixed in a dense
suspension of fluidized bed material in the lower fur-
CFB TECHNOLOGY
With CFB technology, the flue gas velocity in the furnace
is higher and the bed is expanded and entrained with
Excellent mixing and heat transfer make fluidized bed technology ideal for a wide range of
applications. A variety of coals and lignites can be combusted, as well as clean biomass ADVANTAGES OF ANDRITZ FLUIDIZED
(bark, agricultural, forestry, and sawmill residuals) and many other fuels (demolition wood, BED TECHNOLOGIES
refuse-derived fuels, peat, various sludges, etc.).
• Fuel flexibility
• High burn-out and conversion rates
• Inherently low emissions
• Excellent availability with long continuous operating periods
• Operational flexibility with good load following capability
• Minimal maintenance
• Proven design
EcoFluid BFB technology, M-real, Hallein, Austria Open nozzle grid, PowerFluid technology, Neumünster, Germany
4 5
EcoFluid BFB boilers BFB APPLICATIONS
FLEXIBLE SOLUTIONS An important feature of the boiler is the design of the Type
In addition to typical biomass fuels such as wood fluidizing nozzle grid, which distributes the primary air
(chips, bark, forest residues, and sawdust), more and drains inert, coarse material such as rocks and
recently short-rotation energy crops, sludges, rejects, other impurities. These materials can cause distur-
agricultural wastes, and Refuse-Derived Fuels (RDF) bances in the bed fluidization if not removed from the
are being introduced as fuel sources. Common charac- furnace. The ANDRITZ fluidizing grid can be designed
Size range 40-420 t/h 30-100 t/h
teristics for these fuels are that they are high in volatile with a unique water-cooled or air-cooled structure, (88-925 klb/hr) (66-220 klb/hr)
matter and have a high variance in moisture content. providing reliable and efficient removal of coarse
These alternative fuels require certain considerations material from the fluidized bed. Main fuels Biomass fuels (bark, chips, RDF, rejects, sludge
in design as well as in the steam output parameters. sawdust), peat
ANDRITZ has technical solutions for a broad range of Secondary fuels Sludges, demolition wood, Biomass fuels, demolition wood,
fuels that can be burned in an EcoFluid boiler. agricultural residues, agricultural residues
Coal up to 20%, TDF
SCAL ABLE AND RELIABLE FORTUM TERMEST
EcoFluid boilers can be either top- or bottom-sup- A .S. PÄRNU, ESTONIA
ported, depending on the desired capacity and site EFFICIENT AIR POLLUTION CONTROL from Vattenfall) that reduces corrosive alkali chlo-
conditions. Scalability and ease of construction are Fuels Wood, peat, and natural gas Fluidization air (primary air) supplies part of the total rides as well as NOx in flue gases, effectively reduc-
enhanced since the main boiler components are combustion air and creates gasification conditions ing fouling and corrosion of the superheaters. These
Technical data Steam output: 94 t/h (207 klb/hr)
designed as modules. The arrangement of all heat- Steam temperature: 525 °C (977 °F) in the lower furnace. The balance of the air (second- measures provide enhanced steam parameters and
ing surfaces is tailored to the customer’s requirements. Steam pressure: 117 bar (1,700 psig) ary and tertiary air) is injected higher up in the furnace boiler reliability using more challenging fuels, while
The boilers are conservatively designed with regard to to complete the combustion process. In combination keeping operating costs to a minimum. Particulates
Features SNCR and bag filter combined with
materials of construction, location and spacing of heat with an adequate reaction time, this reduces CO emis- are removed from the flue gases in an electrostatic
sorbent injection
surfaces, etc. to ensure high plant availability and low sions to low levels, while the gradual addition of oxy- precipitator or fabric filter, depending on customer
maintenance requirements. gen also ensures minimal formation of NOx emissions. preference and environmental requirements. Additional
Further NOx reduction can be achieved by injecting emissions control can be achieved via sorbent injec-
ammonia into the furnace. This system can also be tion to reduce acid gas emissions (SO2, HCl, Hg, and
combined with ChlorOut, a patented process (licence dioxin/furans).
ECOFLUID FE ATURES
• Fuel flexibility
• High efficiency
• High availability
• Modular design
• Low emissions
6 7
ASH HOPPER SCREWS
Radiation pass
8 9
PowerFluid CFB boilers CFB APPLICATIONS
PowerFluid PowerFluid Residues and
Conventional fuels concept refuse-derived fuels concept
Unmatched fuel flexibility – from coal and biomass to alternative fuels
and wastes. CFB technology is the state-of-the art technology for
multi-fuel combustion.
The modular CFB design of an ANDRITZ PowerFluid boiler enables the boiler to utilize conven- BETTMATERIALKUEHLER
tional and alternative fuels. The core components are standardized to deliver efficient, reliable
performance.
Features Hybrid fuel concept for the treatment of fuels with higher chlorine content SUPERIOR ENVIRONMENTAL PERFORMANCE
The removal of nitric oxides (NOx) and sulfur oxides (SOx) is easily accomplished with CFB com-
bustion. PowerFluid boilers can meet strict emission requirements without adding post-combustion
cleaning equipment, such as flue gas desulfurization and selective catalytic reduction systems. The
low temperatures and staged combustion in the furnace prevent thermal NOx formation and sup-
press the oxidation of fuel nitrogen – resulting in low NOx formation and high fuel burn-out rates.
Low cost limestone, used as a sorbent in the furnace, captures the fuel’s sulfur components in a
simple and efficient manner during the combustion process.
POWERFLUID FE ATURES
• Multi-fuel combustion
• Highest fuel flexibility
• Inherently low emissions
• High boiler efficiency
• Proven reliability
10 11
PowerBlast boilers APPLICATIONS
CUSTOMIZED SOLUTIONS
Size range < 350 t/h (< 770 klb/hr) < 600 t/h (< 1,320 klb/hr)
ANDRITZ PowerBlast gas boilers use
these process gases to generate energy Main fuels Process gases Process gases
in an environmentally friendly process.
PowerBlast boilers are customized for Reheat No Yes
the combustion of blast furnace gas,
coke oven gas, and LD converter gas.
There are standardized designs for sin- PowerBlast boilers are flexible by design in handling system to attain the highest efficiencies. As a result
gle-drum concepts, and the El Paso a wide range of process gases with different heating of ANDRITZ’s years of experience with blast furnace
concept for larger units. The Power- values and compositions. Advanced multi-burner tech- gas firing in combination with modern engineering
Blast boiler offers an efficient solution nology helps the boilers achieve extremely low emis- tools and design methods, customers can benefit from
for converting waste gas into elec- sions. The El Paso concept can incorporate a reheat know-how at the highest technological standard.
tric power and heat. The high-pressure
steam can be fed to a turbine for elec-
tricity generation. After partial expan-
sion, the exhaust steam can be used as
process steam or for district heating. PowerBlast technology, Voestalpine, Linz, Austria
12 13
ANDRITZ power plant Selected References
services – Full support
for the life of your plant
ANDRITZ provides analytical services for all engineering
andoperational disciplines in power plants. IGGESUND WORKINGTON, UK – HÄMEENKYRÖN VOIMA , FINL AND – E.ON, BL ACKBURN
ECOFLUID BFB BOILER ECOFLUID BFB BOILER MEADOWS, UK –
Steam conditions: 195 t/h Steam conditions: 105/115 t/h ECOFLUID BFB BOILER
With service and manufacturing centers around the which services are needed, plant o perators can rely on (4000 klb/hr), 540 °C (1004 °F), (232/253 klb/hr), 510 °C (950 °F), Steam conditions: 119 t/h
world, ANDRITZ is well-positioned to offer full support ANDRITZ’s in-depth knowledge, years of experience, 102 bar (1,480 psig) 85 bar (1,230 psig) (262 klb/hr), 490 °C,
before, during, and after the installation of its products. and competitive pricing to deliver results. Fuel: Forest residues, recycled saw- Fuel: Forest residues, bark, sawdust, (914 °F), 85 bar (1,233 psig)
The goal is to achieve the highest overall production mill chips, bark, sludge, sawdust peat, natural gas for start-up Fuel: Wood waste
efficiency (OPE) of a power plant by increasing safety, Start-up year: 2013 Start-up year: 2012 Start-up year: 2013
availability, efficiency, and throughput over the entire
life-cycle. ANDRITZ has analytical tools and expert
assistance to help each customer decide on the most
cost-effective course of action – whether it is simple
tuning, repair, replacement, optimization, or upgrade.
To complement its service capabilities, ANDRITZ man-
ufactures and stocks a range of replacements parts.
Specialists can assist in shutdown planning, on-site
coordination, supervision, and the actual shutdown
work. ANDRITZ experts can be called upon to monitor FORTUM VÄRME, PROPOWER, BOLLNÄS ENERGI,
and advise customers regarding the operation of power VÄRTAVERKET, SWEDEN – EISENHÜTTENSTADT, SWEDEN – ECOFLUID
plants and flue gas treatment systems. Regardless of POWERFLUID CFB BOILER GERMANY – POWERFLUID BFB BOILER
Steam conditions: 467 t/h CFB BOILER Steam conditions: 39 t/h
(1,030 klb/hr), 562 °C (1043 °F), Steam conditions: 176 t/h (388 klb/hr), (86 klb/hr), 420 °C
143 bar (2,074 psig) 470 °C, (878 °F), 70 bar (1,015 psig) (788 °F), 40 bar (580 psig)
FIELD SERVICE AND CONSULTATION REBUILDS AND UPGRADES Fuel: Forestry wood, bark, peat, wood Fuel: RDF, rejects, sludge, coal, Fuel: RDF, forestry wood,
• Field service and consultation • Performance improvement pellets, wood dust, bituminous coal Light fuel oil wood waste
• Inspection • Retrofits Start-up year: 2016 Start-up year: 2011 Start-up year: 2011
• Maintenance • Plant upgrades
• Annual outage and scheduled maintenance • Firing system upgrades
• Long-term service agreement (LTSA) • Pressure part refurbishment/replacement
• Plant operation • Emission reduction
• Measurement and analysis • Co-firing of biomass
• Plant condition assessment • Over-fire air systems of grate-fired boilers
• Training
• Service product development SPARE AND WEAR PARTS
• Life cycle calculation • Replacement 1 : 1
• Process studies • Spare parts STORA ENSO, MAXAU, GERMANY – ADUL ARYA , YUNUS EMRE, TURKEY – RIIKINVOIMA, FINLAND –
• Process tuning • Wear parts POWERFLUID CFB BOILER POWERFLUID CFB BOILER POWERFLUID CFB
• Circulation studies Steam conditions: 198 t/h Steam conditions: 440/414 t/h BOILER
(437 klb/hr), 520 °C (968 °F), (970/913 klb/hr), 543 °C (1009 °F), Steam conditions: 71 t/h
95 bar (1,378 psig) 139/37 bar (2,016/537 psig) (156 klb/hr), 500 °C,
OVERALL PRODUCTION EFFICIENCY (OPE) AGREEMENTS Fuel: Coal, bark, rejects Fuel: Lignite (932 °F), 85 bar (1,233 psig)
Start-up year: 2010 Start-up year: 2013 Fuel: RDF, Light fuel oil
Start-up year: 2016
14 15
ANDRITZ POWER PL ANT SERVICES
With service and manufacturing centers around the world, ANDRITZ is well-
positioned to offer full support before, during, and after the installation of
its products. The goal is to achieve the highest overall production efficiency
(OPE) of a power plant by increasing safety, availability, efficiency, and
throughput over the entire life-cycle.
AUSTRIA
ANDRITZ AG
p: +43 316 501 0
[email protected]
FINL AND
ANDRITZ OY
p: +358 204 50 5555
[email protected]
ANDRITZ.COM
All data, information, statements, photographs and graphic illustrations in this leaflet are without any obligation and raise no liabilities to or
form part of any sales contracts of ANDRITZ AG or any affiliates for equipment and/or systems referred to herein. © ANDRITZ AG 2018. All rights
reserved. No part of this copyrighted work may be reproduced, modified or distributed in any form or by any means, or stored in any database or
retrieval system, without the prior written permission of ANDRITZ AG or its affiliates. Any such unauthorized use for any purpose is a violation of the
relevant copyright laws. ANDRITZ AG, Stattegger Strasse 18, 8045 Graz, Austria. Due to legal considerations, we must inform you that ANDRITZ AG
processes your data for the purposes of informing you about the ANDRITZ GROUP and its activities. Find out more details about our data privacy
declaration and your rights under the data protection legislation on our website: andritz.com/privacy. Power boilers brochure 1.1/07.2018 EN