9 articles

API 610 Cl 6.1.12 defines rated & preferred operating range (POR), which is not
mandatory

Best efficiency flowrate at which a pump achieves its highest efficiency at rated
impeller diameter

Rated flowrate shall be within the region of 80 % to 110 % of best efficiency flowrate
of the pump

Customer duty point not the same as BEP point.

1. Operating point: pump is expected to operate under normal conditions, defined by


Purchaser

2. Rated point: designed & tested at this point, guaranteed by Manufacturer

3. Allowable operating range (AOR): pump is able to operate whilst conforming to


predefined API 610 vibration limits. Cl 6.9.3.1

API 610 vibration levels:

1. < 3mm/s for horizontal pumps and < 5mm/s for vertical pumps within the preferred
operating region

Messaging

https://www.linkedin.com/pulse/centrifugal-pump-operating-range-per-api-610-pramod-tryambake/ 1/2
10/17/2018 (5) Centrifugal Pump Operating Range as per API 610 | LinkedIn

2. Increase by 30% outside the POR but within the AOR 5 Free Upgrade
to Premium

If a manufacturer can guarantee low noise and vibration limits (still within the API 610
limits) for a duty outside of the rated and preferred operating ranges but within the allowable
operating range it should be considered as a perfectly acceptable option.

Report this

3 Likes

0 Comments

Add a comment…

Pramod Tryambake
Power Plant Professional

Follow

More from Pramod Tryambake See all 9 articles

Machine Vibrations Suction Specific Speed (Nss) Wobbe's Index Gas Turbine S
Pramod Tryambake on LinkedIn Pramod Tryambake on LinkedIn Pramod Tryambake on LinkedIn Pramod Tryamb

Select Language
t Questions?
Visit our Help Center. English (English)
munity Guidelines

cy & Terms
Manage your account and privacy.
feedback Go to your Settings.

dIn Corporation © 2018

https://www.linkedin.com/pulse/centrifugal-pump-operating-range-per-api-610-pramod-tryambake/ 2/2

You might also like