Pressure Reducing Valves
Pressure Reducing Valves
Pressure Reducing Valves
Pressure Relief
1 2 3 4 5 6
Operating Data
Data is typical with oil at 22 cSt (106 SUS) and at 50_C (122_F).
Maximum pressures:
Port B (pressure inlet) 350 bar (5000 psi)
Port A (reduced pressure outlet) See model code position 4
Port YJ 2 bar (30 psi)
Rated flow rates at ∆p = 12 bar (175 psi):
X(C)G2V-6 200 L/min (53 USgpm)
X(C)G2V-8 300 L/min (80 USgpm)
Pressure adjustment ranges See model code position 4
Minimum pressure differential (PB - PA)
for effective reduced pressure control,
all models 20 bar (300 psi) approx.
Pilot control drain flow, all models
at PB 100 bar (1450 psi) 1,0 L/min (0.26 USgpm)
at PB 300 bar (4350 psi) 1,3 L/min (0.34 USgpm)
Hydraulic fluids and fluid temperatures See page 3
Temperature limits See page 3
Mass See page 6
Spare parts/service information 40630
J Back pressure at this port is additive to the reduced pressure setting of the valve.
2
Pressure Underride Hydraulic Fluids
X(C)G2V-8 examples All valves can be used with:
Anti-wear hydraulic oils (class L-HM)
psi bar Invert emulsions (class L-HFB)
Water glycol (class L-HFC)
300 Phosphate ester (class L-HFD), adding
4000 “F3-” prefix at model code .1
Reduced pressure
250
The extreme viscosity range is from 500
3000 to 13 cSt (2270 to 70 SUS) but the
200
recommended range is 54 to 13 cSt
(245 to 70 SUS).
150
2000
For further information about fluids see
100 catalog 694.
A petroleum oil.
125
8
Whatever the actual temperature range,
100 C D
6 ensure that viscosities stay within the
75 limits specified in the “Hydraulic Fluids”
50 4 section.
25 2
Contamination Control Requirements
0 Recommendations on contamination
0 50 100 150 200 250 300 L/min control methods and the selection of
products to control fluid condition are
0 10 20 30 40 50 60 70 80USgpm included in Vickers publication 561,
Flow rate “Vickers Guide to Systemic Contamination
Control”. The book also includes
information on the Vickers concept of
From port B to A at pressures below
reduced pressure setting: “ProActive Maintenance”. The following
X(C)G2V-6 . . . . . . . . . . . . . . . . . Curve A recommendations are based on ISO
cleanliness levels at 2 mm, 5 mm and 15
X(C)G2V-8 . . . . . . . . . . . . . . . . . Curve B
mm. For products in this catalog the
From port A to B through check valve recommended levels are:
(main stage assumed closed), XCG2V
Up to 210 bar (3050 psi) . . . . . 19/17/14
models only:
XCG2V-6 . . . . . . . . . . . . . . . . . . . Curve C Above 210 bar (3050 psi) . . . . 19/17/14
XCG2V-8 . . . . . . . . . . . . . . . . . . . Curve D
3
Installation Dimensions in mm (inches)
3rd angle
projection
4 holes Ø11,0 (0.43 dia)
spotfaced to Ø17,0 (0.68 dia) E
61,0 (2.4) F H
C D
45,0 (1.8) for removal of
protective cap
176,0 (6.9)
7,5 (0.29) A/F
Turn clockwise to increase
reduced pressure setting
120,0 (4.7)
17,0 (0.67) 98,0
A/F (3.8)
30,0 (1.2)
16,0 (0.63)
“K” Feature
To adjust pressure setting, insert key
and turn clockwise. Turn micrometer
knob clockwise to increase pressure
Model C D E F H
setting; counter-clockwise to decrease
X(C)G2V-6 42,0 66,0 10,0 89,0 92,0 setting.
(1.7) (2.6) (0.4) (3.5) (3.65)
When the key is removed, the knob can
X(C)G2V-8 40,0 77,0 11,0 104,0 107,0 spin freely without affecting the pressure
(1.6) (3.1) (0.43) (4.1) (4.25) setting.
4
Views on Bottom Face of Valves (See also “Mounting Surfaces”, page 6. All O-seals supplied).
X(C)G2V-6 X(C)G2V-8
(Not used; recess for O-seal only. (Not used; recess for O-seal only.
Port X location) Port X location) Valve locating pin
Valve locating pin
XCGVM-6-10R Subplate
Y
A B Tapped G1 (1I
Port A u BSPF) x 19,0 (0.75)
Tapped G1/4
(1/4I BSPF) x Port Y u depth full thread, in
Port B u 150,0
12,0 (0.5) underside 126,0 69,0 88,0
Port X u (5.0) (2.7) (3.5) (6.0)
depth full R28,0
thread, in un- (1.1 rad.)
derside
X
4 holes tapped Ø 7,5 (0.3 dia) x 6,0
M10 x 16,0 (0.63) (0.24) deep for valve lo-
min. 56,0 cating pin 24,0
18,9
depth full thread (2.2) (0.95)
(0.75)
5
Mounting Surfaces, Based on
ISO 5781 Codes:
C
AG-06-2-A
D (min.) (min.)
EY F (min.)
AH-08-2-A
H
When a subplate is not used a raised J
machined pad must be provided for YK
mounting. The pad must be flat within L Ø M10 x 16,0 (0.63)
Q (min.)
0,01mm/100 mm (0.001I/10I) and M min. depth full thread
smooth within 0,8 mm (32 min).
Dimensional tolerances are "0,2 mm
(0.008I) except where indicated. T Y
S Ø 4,8 (0.19 dia)
Port functions R
PY A U
A = Reduced pressure outlet (also free B
(min.)
reverse flow inlet for XCG2V
valves) X
B = High pressure inlet (also free
reverse flow outlet for XCG2V
valves) N (min.) Ø 4,8 (0.19 dia) Ø 7,5 (0.3 dia) x
X = Not used for X(C)G2V valves; can 6,0 (0.24) deep min.
be omitted or plugged
Y = Drain port
Size L M N P Q R S T U
06 21,4 7,1 10,0 66,7 10,0 58,7 33,3 7,9 87,0
(0.84) (0.28) (0.4) (2.62) (0.4) (2.3) (1.3) (0.31) (3.4)
Y Tolerance on bolt and pin locations
08 20,6 11,1 10,8 79,4 10,8 73,0 39,7 6,4 101,0 "0,1 mm (0.004I).
(0.81) (0.44) (0.43) (3.125) (0.43) (2.87) (1.56) (0.25) (4.0)
Mounting Bolts/Torques
For all models, bolt kit BKXG2V-6.
Bolts should be torqued to 59-73 Nm
(44-53 lbf ft), with threads lubricated.