Vickers®

Pressure Relief

Pressure Reducing Valves


X(C)G2V-6/8, 10 Series
High valve response ensures that the
reduced outlet pressure is unaffected by
Typical Section inlet pressure peaks. Excessive build-up
X(C)G2V-***-1* valve of outlet port pressure (e.g. caused by
flow back from an actuator) is prevented
by the small check in the main-stage
which connects the outlet port to the
pilot stage.

For applications where full reverse flow


is required an optional integral check
valve is available (model types XCG).

Models with electrohydraulic


proportional control, types KX(C)GV, are
described in catalog 2322.

Features and Benefits


F Close matching to machine
requirements with choice of five
adjustment ranges of reduced
pressure.
F Excellent repeatability and stable
performance results from cartridge
design of main-stage parts.
F Minimal pump flow losses when using
several valves in parallel, results from
design of internal pilot system.
F Free reverse flow from integral check
valve option.
F International mounting surfaces.
F Low installed cost and space
Basic Characteristics General Description requirement from high power/size
Max. inlet pressure . . . . . . . . . . 350 bar Where sections of an hydraulic system ratios (more than double that of many
(5000 psi) are required to operate at a pressure conventional designs).
Max. reduced pressure . . . . . . . 330 bar below that of the general system, it is
(4780 psi) frequently more convenient to use a
Maximum flow . . 300 L/min (80 USgpm) pressure reducing valve than to add
Mounting face to ISO 5781 further pump sections.
(B port high pressure inlet):
X(C)G2V-6 . . . . . . . . . . . . . . . AG-06-2-A These two-stage pressure reducing
X(C)G2V-8 . . . . . . . . . . . . . . . AH-08-2-A valves allow full flow from inlet to outlet
port until the reduced pressure setting is
reached, whereupon the outlet flow is
closed off. Reduced pressure setting is
manually adjustable at the pilot stage.
Five ranges of reduced pressure
adjustment are available.

February 1996 GB-2321A


Functional Symbols Model Code
XG2V model (no reverse flow check) For valves with manual adjustment only

(F3-) X (C) G2V- * * * -1*

1 2 3 4 5 6

1 Fluid compatibility 4 Reduced pressure adjustment


Blank = Anti-wear hydraulic oil control range
B A Y
(class L-HM), invert emulsion A = 2 to 35 bar (30 to 500 psi)
(class L-HFB) or water glycol B = 5 to 70 bar (44 to 1000 psi)
XCG2V model (integral check valve for (class L-HFC) C = 5 to 140 bar (44 to 2000 psi)
free flow A to B) F3 = As above or phosphate F = 5 to 210 bar (44 to 3000 psi)
ester (class L-HFD) G = 5 to 330 bar (44 to 4780 psi)

2 Integral check valve (free reverse 5 Type of manual adjustment


flow) K = Micrometer with keylock
C = Integral check valve M = Micrometer without keylock
Omit if not required W = Screw/locknut

B A Y 3 Mounting surface, ISO 5781 6 Design number, 1* series


With B port, high pressure inlet and A Subject to change. Installation
port, reduced pressure outlet dimensions unaltered for design
6 = Size 06 numbers 10-19 inclusive.
8 = Size 08

Operating Data
Data is typical with oil at 22 cSt (106 SUS) and at 50_C (122_F).
Maximum pressures:
Port B (pressure inlet) 350 bar (5000 psi)
Port A (reduced pressure outlet) See model code position 4
Port YJ 2 bar (30 psi)
Rated flow rates at ∆p = 12 bar (175 psi):
X(C)G2V-6 200 L/min (53 USgpm)
X(C)G2V-8 300 L/min (80 USgpm)
Pressure adjustment ranges See model code position 4
Minimum pressure differential (PB - PA)
for effective reduced pressure control,
all models 20 bar (300 psi) approx.
Pilot control drain flow, all models
at PB 100 bar (1450 psi) 1,0 L/min (0.26 USgpm)
at PB 300 bar (4350 psi) 1,3 L/min (0.34 USgpm)
Hydraulic fluids and fluid temperatures See page 3
Temperature limits See page 3
Mass See page 6
Spare parts/service information 40630
J Back pressure at this port is additive to the reduced pressure setting of the valve.

2
Pressure Underride Hydraulic Fluids
X(C)G2V-8 examples All valves can be used with:
Anti-wear hydraulic oils (class L-HM)
psi bar Invert emulsions (class L-HFB)
Water glycol (class L-HFC)
300 Phosphate ester (class L-HFD), adding
4000 “F3-” prefix at model code .1
Reduced pressure

250
The extreme viscosity range is from 500
3000 to 13 cSt (2270 to 70 SUS) but the
200
recommended range is 54 to 13 cSt
(245 to 70 SUS).
150
2000
For further information about fluids see
100 catalog 694.

1000 Temperature Limits


50 Ambient:
Min. . . . . . . . . . . . . . . . . . . –20_C (–4_F)
0 0 Max. . . . . . . . . . . . . . . . . . . 70_C (158_F)
0 50 100 150 200 250 300 L/min
Fluid temperature:
0 20 40 60 80 USgpm Min. . . . . . . . . . . . . . . . . . . –20_C (–4_F)
Flow rate Max.* . . . . . . . . . . . . . . . . . 70_C (158_F)
* To obtain optimum service life from both
fluid and hydraulic system, 65_C (150_F)
Pressure Drop normally is the maximum temperature
except for water-containing fluids.
psi bar For synthetic fluids consult fluid
175 12 manufacturer or Vickers representative
150 B where limits are outside those of
10
Pressure drop

A petroleum oil.
125
8
Whatever the actual temperature range,
100 C D
6 ensure that viscosities stay within the
75 limits specified in the “Hydraulic Fluids”
50 4 section.
25 2
Contamination Control Requirements
0 Recommendations on contamination
0 50 100 150 200 250 300 L/min control methods and the selection of
products to control fluid condition are
0 10 20 30 40 50 60 70 80USgpm included in Vickers publication 561,
Flow rate “Vickers Guide to Systemic Contamination
Control”. The book also includes
information on the Vickers concept of
From port B to A at pressures below
reduced pressure setting: “ProActive Maintenance”. The following
X(C)G2V-6 . . . . . . . . . . . . . . . . . Curve A recommendations are based on ISO
cleanliness levels at 2 mm, 5 mm and 15
X(C)G2V-8 . . . . . . . . . . . . . . . . . Curve B
mm. For products in this catalog the
From port A to B through check valve recommended levels are:
(main stage assumed closed), XCG2V
Up to 210 bar (3050 psi) . . . . . 19/17/14
models only:
XCG2V-6 . . . . . . . . . . . . . . . . . . . Curve C Above 210 bar (3050 psi) . . . . 19/17/14
XCG2V-8 . . . . . . . . . . . . . . . . . . . Curve D

3
Installation Dimensions in mm (inches)

3rd angle
projection
4 holes Ø11,0 (0.43 dia)
spotfaced to Ø17,0 (0.68 dia) E

61,0 (2.4) F H

C D
45,0 (1.8) for removal of
protective cap
176,0 (6.9)
7,5 (0.29) A/F
Turn clockwise to increase
reduced pressure setting

120,0 (4.7)
17,0 (0.67) 98,0
A/F (3.8)

30,0 (1.2)
16,0 (0.63)

G1/4I (1/4I BSPF) Port A, reduced Port B, high


reduced pressure pressure outlet pressure inlet Type K only:
gage port 25,0 18,0 (0.7) for key removal
196,0 (7.7) fully out
(1.0)

Micrometer Adjustment Options:


“K” or “M” in Model Code 5

“K” Feature
To adjust pressure setting, insert key
and turn clockwise. Turn micrometer
knob clockwise to increase pressure
Model C D E F H
setting; counter-clockwise to decrease
X(C)G2V-6 42,0 66,0 10,0 89,0 92,0 setting.
(1.7) (2.6) (0.4) (3.5) (3.65)
When the key is removed, the knob can
X(C)G2V-8 40,0 77,0 11,0 104,0 107,0 spin freely without affecting the pressure
(1.6) (3.1) (0.43) (4.1) (4.25) setting.

4
Views on Bottom Face of Valves (See also “Mounting Surfaces”, page 6. All O-seals supplied).

X(C)G2V-6 X(C)G2V-8

(Not used; recess for O-seal only. (Not used; recess for O-seal only.
Port X location) Port X location) Valve locating pin
Valve locating pin

Port A (reduced Port B (high


pressure outlet) pressure inlet) Port A (reduced Port B (high
pressure outlet) pressure
inlet)
Port Y (see “Functional Symbols” for usage)
Port Y (see “Functional Symbols” for usage)

XCGVM-6-10R Subplate

116,0 (4.5) 43,0 (1.7)


104,0 (4.1) 21,0 (0.83)
4 holes, Ø 11,0 (0.43
12,0 (0.5) 80,0 (3.15) 20,0 (0.8)
dia) through, Ø 17,5
26,9 (1.06) (0.69 dia) spotface

Y
A B Tapped G1 (1I
Port A u BSPF) x 19,0 (0.75)
Tapped G1/4
(1/4I BSPF) x Port Y u depth full thread, in
Port B u 150,0
12,0 (0.5) underside 126,0 69,0 88,0
Port X u (5.0) (2.7) (3.5) (6.0)
depth full R28,0
thread, in un- (1.1 rad.)
derside
X
4 holes tapped Ø 7,5 (0.3 dia) x 6,0
M10 x 16,0 (0.63) (0.24) deep for valve lo-
min. 56,0 cating pin 24,0
18,9
depth full thread (2.2) (0.95)
(0.75)

Y See “Mounting Surfaces” section on next page for port usage.

5
Mounting Surfaces, Based on
ISO 5781 Codes:
C
AG-06-2-A
D (min.) (min.)
EY F (min.)
AH-08-2-A
H
When a subplate is not used a raised J
machined pad must be provided for YK
mounting. The pad must be flat within L Ø M10 x 16,0 (0.63)
Q (min.)
0,01mm/100 mm (0.001I/10I) and M min. depth full thread
smooth within 0,8 mm (32 min).
Dimensional tolerances are "0,2 mm
(0.008I) except where indicated. T Y
S Ø 4,8 (0.19 dia)
Port functions R
PY A U
A = Reduced pressure outlet (also free B
(min.)
reverse flow inlet for XCG2V
valves) X
B = High pressure inlet (also free
reverse flow outlet for XCG2V
valves) N (min.) Ø 4,8 (0.19 dia) Ø 7,5 (0.3 dia) x
X = Not used for X(C)G2V valves; can 6,0 (0.24) deep min.
be omitted or plugged
Y = Drain port

Size A dia. B dia. C D E F H J K


06 14,7 14,7 61,0 9,0 42,9 9,0 35,7 31,8 21,4
(0.58) (0.58) (2.4) (0.4) (1.69) (0.4) (1.4) (1.25) (0.84)
08 23,4 23,4 78,0 8,8 60,3 8,8 49,2 44,5 39,7
(0.92) (0.92) (3.1) (0.35) (2.37) (0.35) (1.94) (1.75) (1.56)

Size L M N P Q R S T U
06 21,4 7,1 10,0 66,7 10,0 58,7 33,3 7,9 87,0
(0.84) (0.28) (0.4) (2.62) (0.4) (2.3) (1.3) (0.31) (3.4)
Y Tolerance on bolt and pin locations
08 20,6 11,1 10,8 79,4 10,8 73,0 39,7 6,4 101,0 "0,1 mm (0.004I).
(0.81) (0.44) (0.43) (3.125) (0.43) (2.87) (1.56) (0.25) (4.0)

Installation Data Mass


Mounting attitude unrestricted X(C)G2V-6 valves . . . . . 4,8 kg (10.6 lb)
X(C)G2V-8 valves . . . . . 5,6 kg (12.4 lb)
Subplates
For X(C)G2V-6 valves see type Ordering Procedure
XCGVM-6-10R, on page 5. All valves, subplates, bolt kits should be
For X(C)G2V-8 valves consult your ordered by full model code designation.
Vickers representative.

Mounting Bolts/Torques
For all models, bolt kit BKXG2V-6.
Bolts should be torqued to 59-73 Nm
(44-53 lbf ft), with threads lubricated.