Single-Phase KWH Meter Calibrator: Features

The GF112B is a single-phase kWh meter calibrator that can test various types of single-phase meters on site and measure alternating current parameters. It has an integrated current clamp and touchscreen display, runs on rechargeable batteries for up to 8 hours, and can automatically record and save up to 999 test results. Key features include high measurement accuracy of 0.2-0.5% for active power, energy, and other parameters like voltage, current, power factor, and frequency over specified measurement ranges.

Uploaded by

Vidi Putra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
94 views2 pages

Single-Phase KWH Meter Calibrator: Features

The GF112B is a single-phase kWh meter calibrator that can test various types of single-phase meters on site and measure alternating current parameters. It has an integrated current clamp and touchscreen display, runs on rechargeable batteries for up to 8 hours, and can automatically record and save up to 999 test results. Key features include high measurement accuracy of 0.2-0.5% for active power, energy, and other parameters like voltage, current, power factor, and frequency over specified measurement ranges.

Uploaded by

Vidi Putra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

GF112B

ENERGY METER CALIBRATION

GF112B
Single-Phase kWh Meter Calibrator
GF112B Single-Phase kWh Meter Calibrator is suitable
to test various types single phase meters on site and
also can be used to test alternating current parameters.

Features
1. It combine the current clamp and the meter together,
displayed by colorful and touch-screen
2. The AAA Li-battery can work 4 hours continuously
3. It can display all the measuring parameters in one screen
4. With wide voltage measuring range 15-300V and current measuring range 0.005-120A
5. The current clamp has automatic compensation and calibration function with accuracy class 0.2%
6. The meter and clamp have Integration design
7. 16 bit high accuracy AD switch 32 bit ARM processor core
8. Automatically record and save 999 groups calibrate data
9. Micro-multifunction optic sample
10. Manually/automatically test inductive single phase meters
11. Manually/automatically test electric single phase meters
12. It can measure virtual value of alternating voltage
13. It can measure virtual value of alternating current
14. Testing parameters: active power, phase angle of voltage/current and frequency etc
15. Automatically store testing data, it can save 999 group test results

Parameters
Electrical parameters
Accuracy class 0.2%
Active power measurement accuracy 0.2%, 0.5%
Energy measurement accuracy 0.2%, 0.5%
Power supply AAA type, Li rechargeable battery, 750mAh, 3.6V
It can work 8 hours continuously
Warming-up time < 5 min
Voltage measurement
U Range 15-300V
Accuracy 0.20%

WWW.GFUVE.COM Energy Meter Calibration | EDITION : 14-02 | Page 1 of 2


Subject to change without notice
GF112B
ENERGY METER CALIBRATION

Electrical parameters - continued


Current measurement
I Range 5mA-120A
Accuracy 0.2%
Phase measurement
Range 0.00°-359.99°
Resolution 0.01°
Accuracy 0.05°
Frequency measurement
Range 45-65Hz
Resolution 0. 001Hz
Accuracy 0.005Hz
Power Factor Measurement
Range -1 ~ 0 ~ 1
Resolution 0.001
Accuracy 0.005
Energy pulse output
Pulse constant 25000
Energy Pulse Input
Input range of pulse constant 1-25000
Pulse input level 5V
Mechanical parameters
Dimensions (W×D×H) (mm) 215×60×30
Aperture of current clamp: 20mm
Weight (kg) 0.25 (mains)
0.8 (accessory and box)
Environmental conditions
Working temperature -10°C to 55°C
Working humidity 5%-85%RHD
Storage temperature -25°C to 70°C
Storage humidity 5%-95%RHD

WWW.GFUVE.COM Energy Meter Calibration | EDITION : 14-02 | Page 2 of 2


Subject to change without notice

You might also like