Errores Minisplit CONFORTFRESH Serie Halcon Plus - INPMSG
Errores Minisplit CONFORTFRESH Serie Halcon Plus - INPMSG
Errores Minisplit CONFORTFRESH Serie Halcon Plus - INPMSG
1、To check if the high pressure switch functions
normally or check if there are some wires connected
1、Malfunction of high pressure switch or the
incorrectly;
wiring is loose;
2、To check if there is malfunction with outdoor
2、Malfunction of outdoor electric box;
electric box;
During cooling and drying 3、Low fan speed of outdoor unit;
3、To check if the fan speed is too low;
operation, except indoor fan 4、Poor air return of indoor unit or outdoor
High pressure protection 4、To check if the air return of outdoor and indoor unit
1 E1 operates, all loads stop unit;
of system is poor;
operation. During heating 5、The heat exchangers of indoor unit or outdoor
5、To check if the evaporator and condenser is dirty or
operation, the complete unit stops. unit are dirty;
not, and confirm if the heat exchange of evaporator
6、The system is blocked;
and condenser is well or not;
7、Some air is in the system;
6、To check if the system is blocked;
8、The panel of outdoor unit is not closed firmly.
7、To check if there is some air in the system;
8、Check if the panel of outdoor unit is firmly closed
1、To check if there are any obstructions, and make
sure the air‐return is smoothly;
1、 Poor air‐return in indoor unit;
2、To check if the running speed of the fan motor is
2、Fan speed is abnormal;
During cooling and drying normal, if not, please replace a new fan motor or PCB;
3、 The evaporator is dirty;
2 E2 Antifreezing protection operation, compressor and outdoor 3、To check if the Evaporator/ filter is dirty or not, if
4、 Refrigerant leakage;
fan stop while indoor fan operates. yes,please clear;4、Add refrigerant per name plate or
5 、The resistance of tube sensor is abnormal;
instruction from factory;
6、 The malfunction of indoor unit controller.
5、Replace a new corresponding tube sensor;
6、Replace a new corresponding indoor controller.
1、The LPP connecting terminal wires of the PCB 1、To check if the LPP connecting terminal wires of the
doesn't connect well with the high pressure PCB connects well with the high pressure switch;
switch; 2、 To check if the wires of the high pressure switch
2、The wiring of the high pressure switch circuit is circuit loose or not.And to check if the high pressure
The complete unit will stop broken.Or the high pressure switch is switch is OK or not;
3 E3 Low pressure protection
operation. broken;3、The system is lack of refregerant Or 3、To check if the system is lack of refregerant Or the
the refregerant leaks; refregerant leaks or not;
4、The input of the LPP is high level. 4、To check if the input of the LPP is high level or not.
5、Check if the panel of outdoor unit is firmly 5、To check if the panel of outdoor unit is firmly
closed; closed;
1、To check if the airflow of outdoor unit is poor;
1、The airflow of outdoor unit is poor; 2、 To check if the fan speed of outdoor unit is too
During cooling and drying 2、Fan speed of outdoor unit is too low; low;
operation, compressor and outdoor 3、The refrigerant is with leakage; 3、 To check if the system is leakage;
High discharge
fan stop while indoor fan operates. 4、The system is blocked; 4、 To check if the system is blocked;
4 E4 temperature protection
During heating operation, all loads 5、The resistance of the discharge temperature 5、To check if the resistance of the discharge
of compressor
stop. sensor is abnormal; temperature sensor is abnormal;
6、The outdoor electric box has malfunction; 6、 To check if the electric box of outdoor unit is
7、Some air is in the system. broken;
7、 To check if there is some air in the system.
1、 To check if the supply voltage is stable or not. If
1、The supply voltage is unstable.It should be
not, please add a voltage regulator;
90%‐110% rated voltage;
2、To check if the supply voltage is too low and the
2、The supply voltage is too low.The burthen is
burthen is too heavy.If yes, improve the power supply
too heavy;
voltage;
3、Test the current of the live wire.If the current
During cooling and drying 3、 To check if the current of the live wire is larger than
doesn't larger than the value of overload
operation, compressor and outdoor the value of overload protection.If not, please check the
protection,please check the PCB;
5 E5 Over current protection fan stop while indoor fan operates. PCB;
4、The heat exchangers are too dirty,or there are
During heating operation, all loads 4、To check if the heat exchangers are dirty or there
some defects of air return;
stop. are some defects of air return;
5、The fan speed is not normal;
5、To check if the fan speed is abnormal;
6、The compressor doesn't run.Or there is some
6、To check if the compressor doesn't run.Or there is
malfunction such as: noise, oil leaks,compressor
some malfunction such as: noise, oil leaks,compressor
shell too hot and so on;
shell too hot and so on;
7、There are some blocks in the system.
7、To check if there are some blocks in the system.
1、To check if the supply voltage is too low or the
1、Improper supply voltage or mismatched
indoor and outdoor units are matched;
indoor and outdoor unit;
2、To check if the wiring between indoor and outdoor
2、Improper wiring between indoor unit and
During cooling operation, unit is proper;
outdoor unit;
compressor stops while indoor fan 3、To check if the PCB of indoor has malfunction;
Communication 3、The PCB of indoor has malfunction;
6 E6 motor operates. During heating 4、To check if the electric control assy of indoor unit
Malfunction 4、The electric control assy of indoor unit has
operation, the complete unit stops. has malfunction;
malfunction;
5、To check if the electric box of outdoor has
5、The electric box of outdoor has malfunction;
malfunction;
6、The electric control assy of outdoor unit has
6、To check if the electric control assy of outdoor unit
malfunction.
has malfunction.
1、To check tube temperature sensor of indoor unit is
During cooling operation: 1、The tube temperature sensor of indoor unit
normal, try to replace tube temperature sensor.
compressor will stop while indoor has malfunction;
High temperature 2、To check if the fan motor of indoor unit is broken, if
7 E8 fan will operate. During heating 2、Fan speed of indoor unit is low
resistant protection yes,replace a new one.
operation, the complete unit stops. 3、The environment of air‐return is poor; for
3、To check if the evaporator and condenser are dirty
example evaporator and condenser are dirty;
or not, if yes, please clear
Circuit PG motor
Operation of remote controller or
indoorfan) has circuit
8 U8 control panel is available, but the Indoor control board is damaged. To replace a new PCB of indoor unit.
malfunction by zero ross
unit wont act.
detection
1、To check if there is no jumper on the PCB, please
1、There is no jumper cap on the mainboard;
add a jumper;
Malfunction protection The complete unit will stop 2、The jumper cap is not inserted correctly;
9 C5 2、To check if the jumper is inserted correctly;
of jumper cap operation. 3、The jumper cap is broken;
3、 To check if the jumper is damaged;
4、The PCB is broken.
4、To check if the PCB is broken.
1、poor contact or loose of indoor temperature
1、To check if the sensor wire plug is loose from the
sensor;
PCB or not;
2、The malfunction of temperature sensor part;
2、To replace the parts of temperature sensor circuit;
During cooling and drying 3、The resistance of temperature sensor
3、To check if the resistance of temperature deviates;
Indoor ambient operation, indoor unit operates deviates;
4、To check if use the wrong sensor;
10 F1 temperature sensor is while other loads will stop; during 4、Use wrong temperature sensor;
5、To check if there is short circuit between sensor and
open/short circuited heating operation,the complete 5、Short circuit between temperature sensor and
shell or copper tube;
unit will stop operation. shell or copper tube;
6、To replace the resistance of temperature sensor
6、The resistance of circuit of temperature sensor
circuit or capacitance;
deviates or creepage of capacitance;
7、To replace the controller.
7、The chip of controller is abnormal.
1、poor contact or loose of indoor temperature 1、To check if the sensor wire plug is loose from the
sensor; PCB or not;
2、The malfunction of temperature sensor parts 2、 To replace the parts of temperature sensor
During cooling and drying ;3、The resistance of temperature sensor circuit;
Indoor evaporator operation, indoor unit will operate deviates; 3、To check if the resistance of temperature deviates;
11 F2 temperature sensor is while other loads will stop; During 4、Use wrong temperature sensor; 4、To check if use the wrong sensor;
open/short circuited heating operation, the complete 5、Short circuit between temperature sensor and 5、To check if there is short circuit between sensor and
unit will stop operation. shell or copper tube; shell or copper tube;
6、The resistance of circuit of temperature sensor 6、To replace the resistance of temperature sensor
deviates or creepage of capacitance; circuit or capacitance;
7、The chip of controller is abnormal. 7、To replace the controller.
1、poor contact or loose of indoor temperature
1、To check if the sensor wire plug is loose from the
sensor;
PCB or not;
2、The malfunction of temperature sensor parts
2、To replace the parts of temperature sensor circuit;
During cooling and drying ;3、The resistance of temperature sensor
3、To check if the resistance of temperature deviates;
Outdoor ambient operating, compressor stops while deviates;
4、To check if use the wrong sensor;
12 F3 temperature sensor is indoor fan operates;During heating 4、Use wrong temperature sensor;
5、To check if there is short circuit between sensor and
open/short circuited operation, the complete unit will 5、Short circuit between temperature sensor and
shell or copper tube;
stop operation shell or copper tube;
6、To replace the resistance of temperature sensor
6、The resistance of circuit of temperature sensor
circuit or capacitance;
deviates or creepage of capacitance;
7、To replace the controller.
7、The chip of controller is abnormal.
1、Poor contact or loose of indoor temperature
1、To check if the sensor wire plug is loose from the
sensor;
PCB or not;
2、The malfunction of temperature sensor parts
2、To replace the parts of temperature sensor circuit;
During cooling and drying ;3、The resistance of temperature sensor
3、To check if the resistance of temperature deviates;
Outdoor condenser operation, compressor stops while deviates;
4、To check if use the wrong sensor;
13 F4 temperature sensor is indoor fan will operate; During 4、Use wrong temperature sensor;
5、To check if there is short circuit between sensor and
open/short circuited heating operation,the complete 5、Short circuit between temperature sensor and
shell or copper tube;
unit will stop operation. shell or copper tube;
6、To replace the resistance of temperature sensor
6、The resistance of circuit of temperature sensor
circuit or capacitance;
deviates or creepage of capacitance;
7、To replace the controller.
7、The chip of controller is abnormal.
1、poor contact or loose of indoor temperature
1、To check if the sensor wire plug is loose from the
sensor;
PCB or not;
During cooling and drying 2、The malfunction of temperature sensor parts
2、To replace the parts of temperature sensor circuit;
operation, compressor will sop after ;3、The resistance of temperature sensor
3、To check if the resistance of temperature deviates;
Outdoor discharge operating for about 3 mins, while deviates;
4、To check if use the wrong sensor;
14 F5 temperature sensor is indoor fan will operate; During 4、Use wrong temperature sensor;
5、To check if there is short circuit between sensor and
open/short circuited heating operation, the complete 5、Short circuit between temperature sensor and
shell or copper tube;
unit will stop after operating for shell or copper tube;
6、To replace the resistance of temperature sensor
about 3 mins. 6、The resistance of circuit of temperature sensor
circuit or capacitance;
deviates or creepage of capacitance;
7、To replace the controller.
7、The chip of controller is abnormal.
1、To check if the evaporator and condenser are dirty
1、The evaporator and condenser are dirty
or not, if yes, please clear.
2、The pressure of the system is abnormal, or the
2、To check if the pressure of the system is normal or
Limit/ decrease All loads operate normally, while refrigerant is too much
not,and to check if the refregerant is excessive or not;
15 F6 frequency due to operation frequency for compressor 3、The temperature sensor of outdoor unit has
3、To check if the temperature sensor of outdoor unit
overload is decreased malfunction.
is OK or not;
4.The PCB of outdoor unit has malfunction.
4、Replace a new PCB of outdoor unit;
5. The compressor has malfunciton.
5、Replace a new compressor.
1、To check if the voltage is too low.If yes, adjust
1、The input supply voltage is not it;2、To check if the evaporator and condenser are
stable;2、The evaporator and condenser are dirty or not, if yes, please clear;3、To check if the
All loads operate normally, while
Decrease frequency due dirty;3、The system pressure is abnormal or the pressure of the system is normal or not,and to check if
16 F8 operation frequency for compressor
to overcurrent refrigerant is excessive;4、The outdoor the refrigerant is excessive or not;4、To check if the
is decreased
temperature sensor is broken;5、The outdoor temperature sensor of outdoor unit is OK or
PCB is broken;6、The compressor is broken. not;5、To replace a new corresponding outdoor unit
PCB;6、To replace a new corresponding compressor.
1、To check if the evaporator and condenser are dirty
1、The evaporator and condenser are dirty; or not, if yes, please clear;
2、The system pressure is abnormal or the 2、To check if the pressure of the system is normal or
All loads operate normally, while
Decrease frequency due refrigerant is excessive; not,and to check if the refrigerant is excessive or not;
17 F9 operation frequency for compressor
to high air discharge 3、The outdoor temperature sensor is broken; 3、To check if the temperature sensor of outdoor unit
is decreased
4、The outdoor PCB is broken; is OK or not;
5、The compressor is broken. 4、To replace a new corresponding outdoor unit PCB;
5、To replace a new corresponding compressor.
During cooling and drying
operation, compressor will stop 1、To check if the input supply voltage is too low.If yes,
1、The input supply voltage is not stable;
18 PH Over Voltage Protection while indoor fan will operate;During adjust it;
2 、Malfunction of outdoor unit controller.
heating operation, the complete 2、To replace a new corresponding outdoor unit PCB.
unit will stop operation.
During cooling and drying
operation, the compressor will stop
Malfunction of complete
19 U5 while indoor fan will operate;During The PCB is broken. To replace a new corresponding outdoor unit PCB.
units current detection
heating operating,the complete
unit will stop operation.
1、To check if the wiring of the compressor is
1、The wiring of the compressor is connected
connected correctly, or the electric box and compressor
improperly,or mismatch between electric box and
mismatch;
compressor;
2、To confirm if the stop duration of the compressor is
2、Someone turns off the unit and then turns on
During cooling and drying longer than 3 minutes;
the unit before the compressor stopped for
operation, compressor will stop 3、To check if the pressure of the system is too low;
Compressor Overcurrent 3minutes;3、The voltage is too low;
20 P5 while indoor fan will operate;During 4、To check if the protection under overload is OK or
Protection 4、Protection under overload is abnormal;
heating operation, the complete not;
5、System abnormal such as excessive
unit will stop operation. 5、To check if the system is normal. Such as excessive
refregerant、pipeline blocked 、dirty evaporator
refregerant、pipeline blocked 、dirty evaporator or
or condenser;
condenser;
6、Malfunction of outdoor unit controller;
6、To replace a new corresponding PCB;
7、Malfunction of the compressor.
7、To replace a new corresponding compressor.
Defrosting will occur in heating
It is a kind of normal state in heating mode.When
mode. Compressor will operate
21 H1 Defrosting H1 starts, the fan will stop.But the fan will start Normal defrosting function
while indoor fan will stop
running in a few minutes.
operation.
1、The wiring of the dust catcher isn't well 1、To check if the wiring of the dust catcher is well
connected; connected or not;
Static dedusting
22 H2 / 2、There is some dirts on the dust catcher; 2、Clear the dirt of the dust catcher;
protection
3、The dust catcher is broken; 3、Replace a new corresponding dust catcher;
4、The PCB board is broken. 4、Replace a new corresponding PCB.
1、The system is abnormal. For example: 1、To check if the system is abnormal. For example:
refrigerant leaks; expansion valve is blocked; refrigerant leaks; expansion valve is blocked; condenser
condenser or evaporator is dirty;the working or evaporator is dirty; the working condition is bad;
During cooling and drying
condition is bad; 2、To check if the compressor has malfunction;
operation, compressor will stop
Compressor Overheat 2、The compressor has malfunction 3、To check if the wiring of overload switch is loose or
23 H3 while indoor fan will operate;
Protection 3、The wiring of overload switch is loose or pulled pulled off;
During heating operation, the
off; 4、To check if there is malfuction of overload
complete unit will stop operation.
4、Malfuction of overload protection circuit; protection circuit;
5、The malfunction protector is broken; 5、To check if the malfunction protector is broken;
6、The voltage is too low. 6、To check if the voltage is low.
1、To check if the voltage is too low.If yes, adjust it;
1、Improper input voltage;
2、To check if the evaporator and condenser are dirty
2、Evaporator or condenser is dirty;
During cooling and drying or not, if yes, please clean;
3、The system is abnormal or the refrigerant is
operation, compressor will stop 3、To check if the system is normal or not,and check if
excessive ;
24 H4 System is abnormal while indoor fan will operate; the refrigerant is excessive or not;
4、Outdoor or indoor temperature sensor is
During heating operation, the 4、To check if the temperature sensors of the unit are
faulty;
complete unit will stop operation. OK or not;
5、Malfunction of outdoor unit controller;
5、Replace a new corresponding PCB of outdoor unit;
6、Malfunction of the compressor.
6、Replace a new corresponding compressor.
1、The wire of the compressor is connected well 1、To check if the wiring is connected well, or the
and correctly,or there is mismatch between electric box and compressor mismatch;
electric box and compressor; 2、To confirm if the stop duration of the compressor is
2、Someone turns off the unit and then turn on long enough;
unit before compressor stopped for 3minutes; 3、To check if the voltage is too low.If yes, adjust it;
During cooling and drying 3、Low voltage; 4、To check if loading is heavy, if yes, it is the normal
operation, compressor will stop 4、Normal protection under overload; protection under overload;
25 H5 IPM protection while indoor fan will operate; 5、System abnormal such as excessive 5、To check if the system is abnormal,such as excessive
During heating operation, the refregerant、pipeline blocked 、dirty evaporator refregerant、pipeline blocked 、evaporator or
complete unit will stop operation. or condenser; condenser are dirty;
6、Malfunction of outdoor controller 6、To check if the outdoor PCB has malfunction;
7、Malfunction of compressor. 7、To check if the compressor is damaged.
8.The indoor and outdoor fans are running 8.To check if the indoor and outdoor fans are running
abnormally. normally.
9. The pressure of the system is too high. 9. To check if the pressure of the system is too high.
1、Check if motor has been installed correctly, if
terminal is connected firmly, if fan is locked, or if 1、To check if the wires connects well or not.To check
bearing deviates; if the fan motor is intalled ok or not.To check if the fan
2、Fan speed is low because air outlet is is locked;
blocked; 2、To check if the outlet is blocked;
The complete unit will stop 3、Fan capacitor is damaged; 3、To check if the fan capacitor is damaged ;
26 H6 Lock of Indoor Fan
operation. 4、Check if mainboard sends correct control 4、To check if the connection of fan motor and PCB
signal to motor; board is well,if not,please reconnect it;
5、Mainboard does not received feedback 5、To check if the PCB board has malfunction;
signal;6、Motor is locked or damaged; 6、To check if the fan motor is locked or damaged;
7、Chip is abnormal. 7、Replace a new corresponding PCB board.
1、To check if the supply voltage is not stable.Please
1、Sudden change of supply voltage of electric
add a voltage regulator;
During cooling and drying net;
2、To replace a new corresponding PCB .(Single PCB )
operation, compressor will stop 2、Short circuit of electric reactor or PFC
;
27 HC PFC protection while indoor fan will operate;During inductance;
3、To replace a new corresponding PFC
heating operation, the complete 3、The PCB is faulty ;
module.(multiple PCBs);
unit will stop operation. 4、The reactor is faulty.
4、To replace a new corresponding reactor.
5.The induction is broken.
5.To replace a new corresponding induction.
1、To check if the voltage is too low.If yes, adjust it;
1、Improper input voltage;
During cooling and drying 2、To check if the pressure of the system is normal or
2、The pressure of the system is abnormal;
operation, compressor will stop not,and to check if the refrigerant is excessive or not;
3、Malfunction of outdoor unit controller ;
28 H7 Motor Desynchronizing while indoor fan will operate; 3、To replace a new corresponding PCB;
4、malfunction of the compressor;
During heating operation, the 4、To replace a newcorresponding compressor;
5.The fan motor is faulty;
complete unit will stop operation. 5、To replace a new corresponding fan motor;
6.The radiator is faulty.
6、To replace a new corresponding radiator.
1、The supply voltage is not stable.It should be
90%‐110% rated voltage; 1、To check if the supply voltage is too low.If yes,
2、The voltage is too low.The burthen is too adjust it;
heavy; 2、To check if the burthen is heavy,if yes,please
3、Test the current of the live wire.If the current decrease the burthen;
Decrease frequency due doesn't larger than the value of overload 3、Try to replace a new corresponding PCB;
All loads operate normally, while
to high temperature protection,please check the controller; 4、To check if the condenser is too dirty,or there are
29 H0 operation frequency for compressor
resistant during heating 4、The condenser is too dirty,or there are some some defects of air return;
is decreased
operation defects of air return; 5、To check if the rotational speed of fan is normal, if
5、The fan speed is not normal; no,try to replace a new corresponding fan;
6、The compressor doesn't run.Or there is some 6、To check if the compressor is damaged,if yes,replace
malfunctions such as: noise, oil leaks,compressor a new corresponding compressor;
shell too hot and so on; 7、To check if the system blocked or not.
7、There are some blocks in the system.
1、To check if the wiring of compressor is connected
1、The wiring of the compressor is not connected
properly or not;
properly ;
During cooling and drying 2、To check if the pressure of the system is normal or
2. The pressure of the system is abnormal;
operation, compressor will stop not;
3、The refrigerant is excessive ;
30 LC Failure startup while indoor fan will operate; 3、To check if the refrigerant is excessive or not;
4、The controller is abnormal;
During heating operation, the 4、To replace a new corresponding outdoor unit PCB;
5、Malfunction of the compressor;
complete unit will stop operation. 5、To replace a new corresponding compressor;
6、Someone turns off the unit and then turn on
6、To confirm if the stop duration of the compressor is
unit before compressor stopped for 3minutes.
longer than 3 minutes.
During cooling and drying
Malfunction of phase operation, compressor will stop 1、To check if the connection of compressor is well or
1、Malfunction of wiring for compressor;
31 U1 current detection circuit while indoor fan will operate; not;
2、Outdoor PCB is faulty
for compressor During heating operation, the 2、Replace a new corresponding PCB.
complete unit will stop
During cooling and drying
operation, compressor will stop
32 EE EEPROM malfunction while indoor fan will operate; Outdoor PCB is faulty To replace a new corresponding PCB of outdoor unit.
During heating operation, the
complete unit will stop
1、The voltage is too low.Please add voltage
During cooling and drying
1、Improper input voltage; regulator;
operation, compressor will stop
Charging malfunction of 2、Poor connection on reactor; 2、To check if the connection of reactor is normal or
33 PU while indoor fan will operate;During
capacitor 3、Reactor is damaged; not;
heating operation, the complete
4、The PCB is faulty. 3、To check if the reactor is damaged;
unit will stop
4、To check if the PCB has malfunction.
During cooling and drying
Malfunction of module operation, compressor will stop
Circuit malfunction of outdoor controller
34 P7 temperature sensor while indoor fan will operate;During To replace a new corresponding PCB of outdoor unit.
temperature sensor of module
circuit heating operation, the complete
unit will stop
1、To check the radiator of the PCB is installed well or
During cooling
not.If not, please adjust;
operation,compressor will stop 1、The wire connection of the radiator looses;
Module high 2、To check if the silicone grease is dry or not, if yes,
35 P8 while indoor fan will operate; 2、The silicone grease is not enough;
temperature protection please add silicone grease;
During heating operation, the 3、The PCB is faulty.
3、To replace a new corresponding PCB of outdoor
complete unit will stop
unit.
1、The voltage is not stable.Please add a voltage
During cooling and drying 1、Supply voltage is unstable;
regulator;
operation, compressor will stop 2、Wrong wiring connection of indoor unit;
Malfunction of voltage 2、Reconnect the wiring;
36 U3 while indoor fan will operate;During 3、Protective tube is faulty;
dropping for DC bus‐bar 3、Replace a new corresponding protective tube;
heating operation, the complete 4、Transformer is faulty;
4、Replace a new transformer;
unit will stop 5、The PCB is faulty.
5、Replace a new corresponding PCB.
During cooling and drying
1、The voltage is too low.Please add a voltage
operation, compressor will stop
Voltage of DC bus‐bar is 1、Supply volatge is too low; regulator;
37 PL while indoor fan will operate;During
too low 2、The PCB is faulty. 2、To replace a new corresponding PCB of outdoor
heating operation, the complete
unit.
unit will stop
1、To check the radiator of the PCB is installed well or
Limit/decrease All loads operate normally, while 1、The wire connection of the radiator looses; not.If not, please adjust;
38 EU frequency due to high operation frequency for compressor 2、The silicone grease is not enough; 2、 To check if the silicone grease is dry or not, if yes,
temperature of module is decreased 3、The PCB is faulty. please add silicone grease;
3、To replace new corresponding PCB of outdoor unit.
1、If the voltage is lower than 175V,please add a
1、Supply volatge is too low;
voltage regulator;
If this malfunction occurs during 2、Wiring terminal on reversing valve is loose or
The four‐way valve is 2、 To confirm if the connection wiring of the four‐way
39 U7 heating operation, the complete broken;
abnormal valve is well or not, if not, please adjust;
unit will stop operation. 3、Reversing valve is faulty;
3、Replace a new corresponding four‐way valve;
4、The PCB is faulty.
4、 Replace a new corresponding PCB.
1、The voltage is not stable.Please add a voltage
1、Supply voltage is unstable;
During cooling operation, regulator;
Zero‐crossing 2、Wrong wiring connection of indoor unit;
compressor will stop while indoor 2、Reconnect the wiring of indoor;
40 U9 malfunction of outdoor 3、Protective tube is faulty;
fan will operate; during heating,the 3、Replace a new corresponding protective tube;
unit 4、Transformer is faulty;
complete unit will stop operation. 4、Replace a new corresponding transformer;
5、The PCB is faulty.
5、Replace a new corresponding PCB.
1、The air‐return of indoor unit is poor, adjust the way
1、Poor air return in indoor unit; of putting goods;2、Fan speed is abnormal, replace a
Limit/decrease All loads operate normally, while
2、Fan speed is too low; new corresponding fan motor;
41 FH frequency due to operation frequency for compressor
3、The temperature sensor is faulty; 3、The temperature sensor is damaging, replace a new
antifreezing is decreased
4、The PCB is faulty. corresponding temperature sensor;
4、Try to replace a new corresponding indoor PCB
1.To insert the connection wires.
1.Wiring is unreliable ;
Outdoor DC Fan 2.To replace a new corresponding fan motor.
42 L3 2.Outdoor DC fan is faulty;
Malfunction 3.To replace a new corresponding electric box of
3.Outdoor PCB is faulty
outdoor unit.
Normal protection.To check if the power of the outdoor
43 L9 Overpower Protection Overpower due to over loading
is close to the most capacity factor.
Mismatch Protection of
1.Models of indoor and outdoor units don't 1、To change a new correct model;
44 LP Indoor and Outdoor
match;2.The jumper is wrong. 2、To replace a new corresponding jumper.
Units
1、Use the right power supply;
1、Voltage of unit is mismatch;
2、Make sure the connection wiring of power is
Mismatch beteween 2、Connection wiring of power is abnormal;
45 UA correct;
indoor and ourdoor unit 3、PCB of outdoor unit is damaging;
3、Replace a new corresponding PCB of outdoor unit;
4、Mismatch between indoor and ourdoor unit.
4、Adjust the match between indoor and outdoor unit.
Refrigerant recovery Add refrigerant per name plate or instruction from
46 Fo The refrigerant is lacking.
mode factory