Acceptance Test Procedure For Alcatel-Lucent Bts A9100

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 20

ACCEPTANCE TEST PROCEDURE

FOR ALCATEL-LUCENT BTS A9100

Site ID :
Address :
Configuration :
Project Reference No:
City/Province :
Position: Longtitude:

Latitude :

Acceptance Test Date :

BTS A9100 A.T.P.


0/19
955.203.312 K / TH 3DB 02841 AAAA / TH
TABLE OF CONTEND

TEST SUMMARY

I. MATERIAL AND HARDWARE INSTALLATION AT THE SITE

II. TECHNICAL ACCEPTANCE TEST AT THE SITE


2.1 Installation acceptance
2.2 Power and Battery test and acceptance
2.3 Antenna and Feeder acceptance
2.4 BTS inspection

III. SERVICE QUALITY INSPECTION


3.1 Voice Quality Test
3.2 Intra BTS handover Test
3.3. GPRS Data call test

IV. OUTSTANDING AND COMMENT

BTS A9100 A.T.P.


1/19
955.203.312 K / TH 3DB 02841 AAAA / TH
TEST SUMMARY

Site ID: HN1607


Data Pass Failure NA

I. BTS HARDWARE REMOTE INVENTORY File attached

II. TECHNICAL ACCEPTANCE TEST AT THE SITE

2.1 Installation acceptance   


2.2 Power and Battery test and acceptance   
2.3 Antenna and Feeder acceptance   
2.4 BTS inspection   

III. SERVICE QUALITY INSPECTION


3.1 Voice Quality Test   
3.2 Intra BTS handover Test   
3.3. GPRS Data call test   

IV. OUTSTANDING AND COMMENT File attached

Alcatel-Lucent Gtel Mobile


(Name and Title) (Name and Title)

BTS A9100 A.T.P.


2/19
955.203.312 K / TH 3DB 02841 AAAA / TH
I. BTS HARDWARE REMOTE INVENTORY

N QT
Project Items Com Code Unit Serial number
o Y
I BTS    
Cabine
1 BTS-9100-IND-MBI53-0
t
2 TGT18 HP Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
3 AGC18 Module
ANTENNA NETWORK COMBINER 1800 EVO Module
ANTENNA NETWORK COMBINER 1800 EVO Module
ANTENNA NETWORK COMBINER 1800 EVO Module
ANTENNA NETWORK COMBINER 1800 EVO Module
4 SUMA Module
5 ANTENNA Module
Module
Module
II POWER SUPPLY
L4V Cabinet with 4 rectifiers 1800W , surge
Cabine
1 protection and power grid with circuit  
t
breakers
L4V DC POWER PLANT WITH 4FLATPAK2
2 Set
1800
3 Battery Fiamm 160Ah String
4 sealed stationary battery Cell
5 Rectifier Card
Rectifier 1
Rectifier 2
Rectifier 3
Rectifier 4
6 AVR
7 Air Condition 1
8 Air Condition 2

9 ACS (external alarm)   Set


10 Extension:

BTS A9100 A.T.P.


3/19
955.203.312 K / TH 3DB 02841 AAAA / TH
II. ONSITE TECHNICAL ACCEPTANCE

2.1 Installation inspection


2.1.1. Feeder, jumper and cable tray:

Requirements Pass Fail


All feeder cable need to be lined and tired up on cable tray,
maximum gap between 02 feeder clamps should not more than  
2m.
Feeder installation should follow technical specification, feeder
need to be connected to grounding system at 03 point (before
connector to antenna, before to leaves BTS tower and before BTS
 
room), in case of distant between 02 grounding connection point
greater than 60m then addition grounding connection point in
between need to be added.
Before to go inside BTS room, Feeder cable need to be lowered
 
and curve to protect water from rain to come inside BTS room.
Feeder panel need to be installed to protect water come inside
 
BTS room.

Feeder curve angle should greater than R ≥ 135o  

Cable tray inside BTS room should be install lined up and the
 
same height level of the hole for install feeder panel.

Cable tray need to be connected to grounding system follow


 
technical specification

All Feeder cables need to be labeled.  

BTS A9100 A.T.P.


4/19
955.203.312 K / TH 3DB 02841 AAAA / TH
2.1.2. Grounding and Lightening protection:

Items Pass Fail

BTS should have 02 grounding bar (Indoor and Outdoor) NA NA


Outdoor grounding bar should be located lower than feeder panel 30
NA NA
cm (G-Tel responsibility).
Location of indoor grounding bar higher than floor 30 cm. NA NA
All of equipment needs to be grounded and connected to main
 
grounding bar.
Each grounding cable connected to grounding bar by individual
 
screw.
Feeder lightening arrester should unique and connected to earth bar.  

2.1.3. BTS and power rack installation:

Items Pass Fail


Equipment should not install under air conditioning system  

BTS and power rack need to fix to floor ensure that it can not fall
 
over.

Power and signal cable need to run on cable tray separately  

All circuit breaker need to be labeled  

General assessment about HW installation:


Pass  Fail 

Alcatel-Lucent Gtel Mobile


(Name and Title) (Name and Title)

BTS A9100 A.T.P.


5/19
955.203.312 K / TH 3DB 02841 AAAA / TH
2.2 Power and battery inspection
(This test is not applicable for BTS share the power with BSC or MSC equipment)

INITIAL CHECK

CHECK FOLLOWING: Pass Fail


1. System installation is completed
 
Check that the system installation has been correctly performed.
2. Rectifier modules are connected
Verify that all rectifier modules are plugged in and the front screws  
fastened
3. Rectifier system connected to mains supply and Protective Earth.
Check that the system’s mains cable is connected to the mains supply
firmly and ground of DC system is connected correctly. Check short circuit  
between ground bar & negative bar of DC system.
Measure voltage of all battery bands. This is about: 48VDC to 55 VDC
4. Alarm system are connected to DDF correctly
Check that the alarm system cables are connected to the DDF with true  
color & identify code

BTS A9100 A.T.P.


6/19
955.203.312 K / TH 3DB 02841 AAAA / TH
SYSTEM START-UP
CHECK FOLLOWING: Pass Fail
1. Turn the system «ON»
Measure input AC voltage of AC system before turn AC automat in V= 223 VAC
Power pack. This is about 190 VAC to 230 VAC
2. Measure output voltage
 
Measure DC output voltage from 48VDC to 55VDC
3. Rectifier modules are «ON» and without fault alarms
Verify that the SMPS modules are in normal mode of operation (not  
reporting alarms)

ALARM LEVELS

CHECK FOLLOWING: Pass Fail


Logging on to Power suite sys & set three alarms as below:
Alarm Output
ID Alarm TB Pin
No
 
1 Main alarm 1 TB2 5&6
2 Rectifier 2 TB2 8&9
3 Battery low 3 TB1 9&10
1. Set the Alarm Levels (High & Low Batt. Alarm)  
High Battery Alarm Voltage at 57 VDC  
Low Battery Alarm Voltage at 45 VDC  
Note: Those threshold is set to default
2. Set the limit charging current to: 23 Ampere (DC)  

SYSTEM ALARMS TEST

Test Mains Off Alarm Pass Fail


Turn off mains on all rectifies  
Verify (Alarm Display) that Mains Off Alarm is activated  
Turn mains power ON and verify that the active alarm is automatically reset  
Test Low Battery Voltage Alarm
- Select General Configuration in Winpower suit  
- Write down the low battery voltage value.  
- Set the minimum value for low battery voltage alarm higher than the  
actual output voltage. Exit by pressing OK button
- Observe that low battery voltage alarm and corresponding alarm relay are  
trigged.
- Set the minimum value back to original number  
Test Rectifier Alarm
- Put one of Rectifier out  
- Verify (Alarm Display) that Rectifier alarm is activated.  
- Put the Rectifier in and verify that the active alarm is automatically reset  

BTS A9100 A.T.P.


7/19
955.203.312 K / TH 3DB 02841 AAAA / TH
2.2.1 Power System

Manufacture Name:
Power capacity:
Capacity of individual rectifier:
Number of rectifier per site :

Items Pass Fail


Designed capacity of power system is sufficient for BTS
 
consumption
AC voltage supply to power system N-L1in the range of 220V±10% V= VAC
Voltage between “Neutral Polar ” and earth < 5V NA NA
Check power system and alarm when one by one rectifier operation
 
(visual lamp test)
Output rectifier voltage 51V ± 5V (Note down the rectifier fail this
 
test in punch list)
Visual check normal operation of each module via lamp and alarm
 
panel
ON/OFF AC Circuit Breaker, BTS should operation normally  
Low volatge alarm of power system is set at 45V (LVA)  
High voltage alarm of power system is set at 57V (HVA)  
Power system need to be shut down when output power is lower
than 43V (LVD: Low Voltage Disconnect) & reconnect when output
NA 
power is higher than 47V (this test only be performed randomly
follow specific requirement from G-Tel Mobile)
Power control system working properly  
Lamp and alarm panel of power and rectifier working properly  

BTS A9100 A.T.P.


8/19
955.203.312 K / TH 3DB 02841 AAAA / TH
2.2.2 Battery
Battery Type: Quantity: 02 set, 04 batteries per set

Items Pass Fail


Measurement individual battery voltage ≥ 12V (in normal mode)  
Measurement battery set voltage, each set voltage ≥ 50V (in normal
 
mode)

Battery discharge test, this test only be performed randomly follow specific
requirement from G-Tel Mobile. (This test to make sure that battery backup time is 4
hours for BTS with configuration Sector 4/4/4, 8 hours for BTS configuration Sector
2/2/2 following the dimensioning rules given per Gtel Mobile):

 Discharge result for first battery set:

Cell 0’ 30’ 1h 2h 3h 4h 5h 6h 7h 8h
1
2
3
4
Sum

 Discharge result for secondary battery set:

Cell 0’ 30’ 1h 2h 3h 4h 5h 6h 7h 8h
1
2
3
4
Sum
 General assessment about power system:
Pass  Fail 
 Commitment of contractor for the site not perform battery discharge
test:
Alcatel-Lucent commits the battery installation for BTS meet all of requirements of
G-Tel mobile as per specification specified in the contract. (Battery backup time is 4
hours for BTS with configuration Sector 4/4/4, 8 hours for BTS configuration Sector
2/2/2 following the dimensionning rules given per Gtel Mobile ).

Alcatel-Lucent Gtel Mobile


(Name and Title) (Name and Title)

BTS A9100 A.T.P.


9/19
955.203.312 K / TH 3DB 02841 AAAA / TH
2.3 Antenna and feeder inspection:
Antenna Desrible:
- Manufacture Name : RFS
- Type of antenna : 1.3m
- Operation frequency : 1800 MHZ
- Antenna installation specification:

Sector Max VSWR Height Azimuth Down tilt


1A (NA) 1.114
39m 60o 6o
1B (NB) 1.096
2A (PA) 1.099
39m 180o 6o
2B (PB) 1.077
3A (QA) 1.096
39m 300o 6o
3B (QB) 1.090

Atenna and Feeder measurement:


Print out Antenna and Feeder measurement for 06 feeders.
Bench mark for VSWR < 1.3 (VSWR for transmission line ≤1.05)
General assessment about antenna and feeder:
Pass  Fail 

Alcatel-Lucent Gtel Mobile


(Name and Title) (Name and Title)

2.4. Acceptance test for BTS equipment:

BTS A9100 A.T.P.


10/19
955.203.312 K / TH 3DB 02841 AAAA / TH
2.4.1. BTS output power:
Bench Mark:
- After combiner : 41dBm -0,5/+1dB (For 4/4/4 configuration only)
- Before combiner : 44,4dBm -0,5/+1dB (For 2/2/2 configuration only)
- Delta output power between TRXs within a cell less than 1W

TRX output power table:

Output power
TRE # Pass Fail Comment
(dBm)

TRE 1 41.30 dBm (13.2 W)


TRE 2 41.45 dBm (13.5 W)
TRE 3 41.62 dBm (13.7 W)
TRE 4 41.45 dBm (13.5 W)
TRE 5 41.40 dBm (14.5 W)
TRE 6 41.37 dBm (13.4 W)
TRE 7 41.30 dBm (13.3 W)
TRE 8 41.34 dBm (13.3 W)
TRE 9 41.20 dBm (13.1 W)
TRE 10 41.58 dBm (13.8 W)
TRE 11 41.15 dBm (13.0 W)
TRE 12 41.47 dBm (13.5 W)

2.4.2. Voice Quality Test per TRX

Voice call need to be conducted on each TRX in order to make sure that TRX is working properly,
Additional test on every time slot might be performed randomly on specific request of G-TEL Mobile.
C1 C2 C3 C4 C5 C6 C7 C8
TRE 1 OK OK OK OK OK OK OK OK
TRE 2 OK OK OK OK OK OK OK OK
Cell 1
TRE 3
TRE 4
TRE 1 OK OK OK OK OK OK OK OK
TRE 2 OK OK OK OK OK OK OK OK
Cell 2
TRE 3
TRE 4
TRE 1 OK OK OK OK OK OK OK OK
TRE 2 OK OK OK OK OK OK OK OK
Cell 3
TRE 3
TRE 4

BTS A9100 A.T.P.


11/19
955.203.312 K / TH 3DB 02841 AAAA / TH
2.43. Test operation of BTS components

Items Contend Requirements Pass Fail


Laptop (LMT) is able Laptop (LMT) is able to log in into
BTS onsite
log in BTS BTS and able to perform local
maintenan  
operation and maintenance,
ce
monitoring BTS operation.
Generate a fake alarm on BTS,
Send alarm report to
Check that the alarm is send to  
OMC and LMT
Test OMC and LMT
System The test performed by remove
alarm the loop back on external alarm
External alarm  
port, alarm need to be sent to
OMC and LMT.
Lock TRE support After that unlock the TRE, BCCH
BCCH channel, channel still remain unchanged
BCCH should at the TRE BCCH previously was
automatically reallocated.  
reallocated to another
TRE of the cell after a
few minute
Recovery
Transmission alarm appears on
and defend Disconnect
OMC, system needs auto clear
machnism transmission between  
alarm when the transmission is
BTS and BSC
resumed.
ONLY Perform this test in some
Shutdown BTS power specific BTS requested by G-TEL
 
then turn ON again mobile, when power resume BTS
should out startup.

General assessment about BTS equipment:


Pass  Fail 

Alcatel-Lucent Gtel Mobile


(Name and Title) (Name and Title)

III. SERVICE ACCEPTANCE TEST

BTS A9100 A.T.P.


12/19
955.203.312 K / TH 3DB 02841 AAAA / TH
3.1. Perform call test

No User Location Calling Sub Called Sub Time Result

1 Intra BTS 01999890145 01998960160 10h30’ OK

2 Intra BSC 01999890145 01998691948 10h40’ OK

3 Inter BSC

3.2. Perform intra_BTS_handover Test:

Sector A to Sector A to Sector B to Sector B to Sector C to Sectro C to


B C A C A B

OK OK OK OK OK OK

3.3 Perform GPRS Data Call Test

Items Pass Fail


Mobile User should be able to attach to GPRS, EDGE or
 
GPRS icon should displayed on handset.

Data send and receive via GPRS and EDGE (WAP services)  

General assessment about BTS services inspection:


Pass  Fail 

Alcatel-Lucent Gtel Mobile


(Name and Title) (Name and Title)

BTS A9100 A.T.P.


13/19
955.203.312 K / TH 3DB 02841 AAAA / TH
IV. BTS COVERAGE INSPECTION
BTS Name: HN1607

Note: Handset with network monitoring function can be used for coverage inspection,
coverage inspection result can be filled in the below form (driver test on 03 difference
direction until the call handed over to other cell or loss coverage, note the Timing
Advance when a call handover and AFRN of the cell handled over or Timing
advance when handset is lost coverage).

4.1. Coverage Inspection for Sector1

Sector 1
Location Distance RX Level HO cell*
Coverage/
0km (at site) TA=0
TA=1 RX=-47
TA=2 RX=-53
TA=3
TA=4
TA=5
TA=6
TA=7
TA=8
TA=9
TA=10

4.2. Coverage Inspection for Sector2

Sector 2
Location Distance RX Level HO cell*
Coverage/
0km (at site) TA=0
TA=1 RX=-59
TA=2 RX=-61
TA=3 Rx=-71
TA=4
TA=5
TA=6
TA=7
TA=8
TA=9
TA=10

BTS A9100 A.T.P.


14/19
955.203.312 K / TH 3DB 02841 AAAA / TH
4.3. Coverage Inspection for Sector3

Sector 3
Location Distance RX Level HO cell*
Coverage/
0km (at site) TA=0
TA=1 RX=-59
TA=2
TA=3
TA=4
TA=5
TA=6
TA=7
TA=8
TA=9
TA=10

Overall Assessment of BTS Coverage Inspection


Pass  Fail 

Alcatel-Lucent Gtel Mobile


(Name and Title) (Name and Title)

BTS A9100 A.T.P.


15/19
955.203.312 K / TH 3DB 02841 AAAA / TH
IV. Outstanding and Recommendation
.......................................................... ....................................................................
............................................................ ..................................................................
......................................................... ................................. ....................................
.......................................................... ....................................................................
............................................................ ..................................................................
......................................................... ................................. ....................................
.......................................................... ....................................................................
............................................................ ..................................................................
......................................................... ................................. ....................................
.......................................................... ....................................................................
............................................................ ..................................................................
.......................................................... ....................................................................
............................................................ ..................................................................
.......................................................... ....................................................................
............................................................ ..................................................................
.......................................................... ....................................................................
............................................................ ..................................................................
.......................................................... ....................................................................
............................................................ ..................................................................
.......................................................... ....................................................................
............................................................ ..................................................................
.......................................................... ....................................................................
............................................................ ..................................................................
.......................................................... ....................................................................

Alcatel-Lucent Gtel Mobile


(Name and Title) (Name and Title)

BTS A9100 A.T.P.


16/19
955.203.312 K / TH 3DB 02841 AAAA / TH
Sector 1
N ANTA
Max VSWR: M1: 1.114; M2: 1.01
Distance-to-fault
M1: 1.114 @ 22.791 Meter M2: 1.01 @ 18.605 Meter
1.40

1.35

Limit : 1.30
1.30

1.25

1.20
VSWR

1.15

1.10

1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 Serial #: 00000000

N ANTB
VSWR Max: M1: 1.096; M2: 1.045
Distance-to-fault
M1: 1.096 @ 23.023 Meter M2: 1.045 @ 18.372 Meter
1.40

1.35

Limit : 1.30
1.30

1.25

1.20
VSWR

1.15

1.10

1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 Serial #: 00000000

BTS A9100 A.T.P.


17/19
955.203.312 K / TH 3DB 02841 AAAA / TH
Sector 2
P ANTA
VSWR Max: M1: 1.099; M2: 1.024
Distance-to-fault
M1: 1.099 @ 22.791 Meter M2: 1.024 @ 18.837 Meter
1.40

1.35

Limit : 1.30
1.30

1.25

1.20
VSWR

1.15

1.10

1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 Serial #: 00000000

P ANTB
VSWR Max: M1: 1.077; M2: 1.018
Distance-to-fault
M1: 1.077 @ 22.791 Meter M2: 1.018 @ 10.465 Meter
1.40

1.35

Limit : 1.30
1.30

1.25

1.20
VSWR

1.15

1.10

1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 Serial #: 00000000

BTS A9100 A.T.P.


18/19
955.203.312 K / TH 3DB 02841 AAAA / TH
Sector 3
Q ANTA
VSWR Max: M1: 1.096; M2: 1.006
Distance-to-fault
M1: 1.096 @ 22.791 Meter M2: 1.006 @ 8.837 Meter
1.40

1.35

Limit : 1.30
1.30

1.25

1.20
VSWR

1.15

1.10

1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 19-Aug-2009 Serial #: 00000000

Q ANTB
VSWR Max: M1: 1.090; M2: 1.022
Distance-to-fault
M1: 1.09 @ 22.791 m M2: 1.022 @ 11.86 m
1.40

1.35

Limit : 1.30
1.30

1.25

1.20
VSWR

1.15

1.10

1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (Meter)
Resolution: 130 CAL: ON(COAX)
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331
19-Aug-2009 Serial #: 00000000

BTS A9100 A.T.P.


19/19
955.203.312 K / TH 3DB 02841 AAAA / TH