Acceptance Test Procedure For Alcatel-Lucent Bts A9100
Acceptance Test Procedure For Alcatel-Lucent Bts A9100
Acceptance Test Procedure For Alcatel-Lucent Bts A9100
Site ID :
Address :
Configuration :
Project Reference No:
City/Province :
Position: Longtitude:
Latitude :
TEST SUMMARY
N QT
Project Items Com Code Unit Serial number
o Y
I BTS
Cabine
1 BTS-9100-IND-MBI53-0
t
2 TGT18 HP Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
A9100 TRX 1800 TWIN Module
3 AGC18 Module
ANTENNA NETWORK COMBINER 1800 EVO Module
ANTENNA NETWORK COMBINER 1800 EVO Module
ANTENNA NETWORK COMBINER 1800 EVO Module
ANTENNA NETWORK COMBINER 1800 EVO Module
4 SUMA Module
5 ANTENNA Module
Module
Module
II POWER SUPPLY
L4V Cabinet with 4 rectifiers 1800W , surge
Cabine
1 protection and power grid with circuit
t
breakers
L4V DC POWER PLANT WITH 4FLATPAK2
2 Set
1800
3 Battery Fiamm 160Ah String
4 sealed stationary battery Cell
5 Rectifier Card
Rectifier 1
Rectifier 2
Rectifier 3
Rectifier 4
6 AVR
7 Air Condition 1
8 Air Condition 2
Cable tray inside BTS room should be install lined up and the
same height level of the hole for install feeder panel.
BTS and power rack need to fix to floor ensure that it can not fall
over.
INITIAL CHECK
ALARM LEVELS
Manufacture Name:
Power capacity:
Capacity of individual rectifier:
Number of rectifier per site :
Battery discharge test, this test only be performed randomly follow specific
requirement from G-Tel Mobile. (This test to make sure that battery backup time is 4
hours for BTS with configuration Sector 4/4/4, 8 hours for BTS configuration Sector
2/2/2 following the dimensioning rules given per Gtel Mobile):
Cell 0’ 30’ 1h 2h 3h 4h 5h 6h 7h 8h
1
2
3
4
Sum
Cell 0’ 30’ 1h 2h 3h 4h 5h 6h 7h 8h
1
2
3
4
Sum
General assessment about power system:
Pass Fail
Commitment of contractor for the site not perform battery discharge
test:
Alcatel-Lucent commits the battery installation for BTS meet all of requirements of
G-Tel mobile as per specification specified in the contract. (Battery backup time is 4
hours for BTS with configuration Sector 4/4/4, 8 hours for BTS configuration Sector
2/2/2 following the dimensionning rules given per Gtel Mobile ).
Output power
TRE # Pass Fail Comment
(dBm)
Voice call need to be conducted on each TRX in order to make sure that TRX is working properly,
Additional test on every time slot might be performed randomly on specific request of G-TEL Mobile.
C1 C2 C3 C4 C5 C6 C7 C8
TRE 1 OK OK OK OK OK OK OK OK
TRE 2 OK OK OK OK OK OK OK OK
Cell 1
TRE 3
TRE 4
TRE 1 OK OK OK OK OK OK OK OK
TRE 2 OK OK OK OK OK OK OK OK
Cell 2
TRE 3
TRE 4
TRE 1 OK OK OK OK OK OK OK OK
TRE 2 OK OK OK OK OK OK OK OK
Cell 3
TRE 3
TRE 4
3 Inter BSC
OK OK OK OK OK OK
Data send and receive via GPRS and EDGE (WAP services)
Note: Handset with network monitoring function can be used for coverage inspection,
coverage inspection result can be filled in the below form (driver test on 03 difference
direction until the call handed over to other cell or loss coverage, note the Timing
Advance when a call handover and AFRN of the cell handled over or Timing
advance when handset is lost coverage).
Sector 1
Location Distance RX Level HO cell*
Coverage/
0km (at site) TA=0
TA=1 RX=-47
TA=2 RX=-53
TA=3
TA=4
TA=5
TA=6
TA=7
TA=8
TA=9
TA=10
Sector 2
Location Distance RX Level HO cell*
Coverage/
0km (at site) TA=0
TA=1 RX=-59
TA=2 RX=-61
TA=3 Rx=-71
TA=4
TA=5
TA=6
TA=7
TA=8
TA=9
TA=10
Sector 3
Location Distance RX Level HO cell*
Coverage/
0km (at site) TA=0
TA=1 RX=-59
TA=2
TA=3
TA=4
TA=5
TA=6
TA=7
TA=8
TA=9
TA=10
1.35
Limit : 1.30
1.30
1.25
1.20
VSWR
1.15
1.10
1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 Serial #: 00000000
N ANTB
VSWR Max: M1: 1.096; M2: 1.045
Distance-to-fault
M1: 1.096 @ 23.023 Meter M2: 1.045 @ 18.372 Meter
1.40
1.35
Limit : 1.30
1.30
1.25
1.20
VSWR
1.15
1.10
1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 Serial #: 00000000
1.35
Limit : 1.30
1.30
1.25
1.20
VSWR
1.15
1.10
1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 Serial #: 00000000
P ANTB
VSWR Max: M1: 1.077; M2: 1.018
Distance-to-fault
M1: 1.077 @ 22.791 Meter M2: 1.018 @ 10.465 Meter
1.40
1.35
Limit : 1.30
1.30
1.25
1.20
VSWR
1.15
1.10
1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 Serial #: 00000000
1.35
Limit : 1.30
1.30
1.25
1.20
VSWR
1.15
1.10
1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (0.0 - 30.0 Meter)
Resolution: 130 CAL: ON(COAX) CW On
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331 19-Aug-2009 Serial #: 00000000
Q ANTB
VSWR Max: M1: 1.090; M2: 1.022
Distance-to-fault
M1: 1.09 @ 22.791 m M2: 1.022 @ 11.86 m
1.40
1.35
Limit : 1.30
1.30
1.25
1.20
VSWR
1.15
1.10
1.05
M2 M1
1.00
0 5 10 15 20 25 30
Distance (Meter)
Resolution: 130 CAL: ON(COAX)
BiasTee: OFF Output Power:
Date: 28-Jul-2009 Time:
Model: S331
19-Aug-2009 Serial #: 00000000