0% found this document useful (0 votes)
163 views4 pages

Economical Analysis For Rising Main: J. M. S. P. L. Dharwad

The document analyzes the economics of different pipe sizes for a rising main to transport water from a water treatment plant to a village. It considers factors like pipe diameter, flow rate, head loss, pumping costs, construction costs, and recommends a 250mm diameter ductile iron pipe as the most economical option based on its total capitalized cost and working pressure. Design calculations are also shown for selecting a pump capable of supplying the required flow against the total dynamic head for the recommended rising main configuration.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
163 views4 pages

Economical Analysis For Rising Main: J. M. S. P. L. Dharwad

The document analyzes the economics of different pipe sizes for a rising main to transport water from a water treatment plant to a village. It considers factors like pipe diameter, flow rate, head loss, pumping costs, construction costs, and recommends a 250mm diameter ductile iron pipe as the most economical option based on its total capitalized cost and working pressure. Design calculations are also shown for selecting a pump capable of supplying the required flow against the total dynamic head for the recommended rising main configuration.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

ECONOMICAL ANALYSIS FOR RISING MAIN

PURE WATER RISING MAIN FROM WTP CLEAR WATER SUMP TO MBT 1 @ REVANSIDDESHWAR TEMPLE VILLAGE

DESCRIPTION
Sl DI Pipe
Pipe Material
No.
Dia of Pipe- in mm 150 200 250 300 350 400

1 DISCHARGE (LPH) 175504 175504 175504 175504 175504 175504

2 PUMPING HOURS 16 16 16 16 16 16

3 LENGTH OF RISING MAIN (m) 3000 3000 3000 3000 3000 3000
DESIGNED LENGTH OF RISING MAIN
4 3300 3300 3300 3300 3300 3300
(m)
VO normal velocity in pipe before
5 2.76 1.55 0.99 0.69 0.51 0.39
closure
6 Frictional Slope in m (s) 0.0577 0.0142 0.0048 0.0020 0.0009 0.0005

7 TOTAL FRICTIONAL LOSS (m) 190.37 46.89 15.82 6.51 3.07 1.60
LOWEST WATER LEVEL AT PUMPING
8 443.00 443.00 443.00 443.00 443.00 443.00
POINT OR JN-GL RL(m)

9 STATIC HEAD 81.50 81.50 81.50 81.50 81.50 81.50

10 DRIVING HEAD 3.00 3.00 3.00 3.00 3.00 3.00

11 COMMON FRICTIONAL HEAD 0.00 0.00 0.00 0.00 0.00 0.00

12 TOTAL GROSS HEAD 274.87 131.39 100.32 91.01 87.57 86.10

13 BHP REQUIRED 297.8 142.3 108.7 98.6 94.9 93.3

14 KW REQUIRED 222.1 106.2 81.1 73.6 70.8 69.6

15 ANNUAL ELECTRICITY CHARGES 4086556 1953447 1491441 1353054 1301964 1280127

16 COST OF PUMPING MACHINERY 2977798 1423441 1086786 985945 948717 932805

17 PUMP DEPRECIATION CHARGES 223335 106758 81509 73946 71154 69960

18 O & M CHARGES 4309891 2060205 1572950 1427000 1373118 1350088

19 RATE OF PIPE / m (in Rs) 1847 2464 3275 4149 4952 5939

20 COST OF PIPE (in Rs) 5541000 7392000 9825000 12447000 14856000 17817000

21 TOTAL CAPITAL COST 8518798 8815441 10911786 13432945 15804717 18749805

22 CAPITALISED COST of O & M 29583092 14141250 10796728 9794926 9425083 9267001

Total Capitalised Cost


38,101,890 22,956,691 21,708,514 23,227,871 25,229,800 28,016,807
+ Capitalised Cost of O & M

J. M. S. P. L. Dharwad
WATER HAMMER DESIGN
PURE WATER RISING MAIN FROM WTP CLEAR WATER SUMP TO MBT 1 @ REVANSIDDESHWAR TEMPLE VILLAGE

SL. Dia (mm)


DESCRIPTION
No. 150 200 250 300 350 400

1 TYPE OF PIPE DI K-9 DI K-9 DI K-9 DI K-9 DI K-9 DI K-9

2 THICKNESS OF PIPE (mm) 6.00 6.30 6.80 7.20 7.70 8.10

3 DISCHARGE (LPH) 175504 175504 175504 175504 175504 175504


4 FULL SUPPLY LEVEL (m) 524.50 524.50 524.50 524.50 524.50 524.50

5 RL OF PUMPHOUSE (m) 444.00 444.00 444.00 444.00 444.00 444.00

6 STATIC HEAD 80.50 80.50 80.50 80.50 80.50 80.50


7 HAMMER PRESSURE VELOCITY (m /s) 1247.69 1210.17 1184.35 1160.67 1143.31 1126.10

8 WATER VELOCITY IN PIPE (m /s) 2.76 1.55 0.99 0.69 0.51 0.39

9 WATER HAMMER PRESSURE (m) 350.87 191.440 119.90 81.60 59.05 44.53

(1) Design Pressure =


10 431.37 271.94 200.41 162.10 139.55 125.03
Static Head + Water Hammer Head

11 (2) Design Pressure = 2 * Static Head 161.00 161.00 161.00 161.00 161.00 161.00

12 Design Head (m) 431.37 271.94 200.41 162.10 161.00 161.00

13 Total Pressure (Ksc) 43.14 27.19 20.04 16.21 16.10 16.10

Economical Size Of Rising Main is 250 mm Dia Pipe, Working Total Water Pressure of 200.41 m, Hence 250 mm dia of DI K-
9 Pipe is recommended.

J. M. S. P. L. Dharwad
60%

DESIGN OF PUMPSET FROM CLEAR WATER SUMP TO MBT-1 @ REVANSIDDESHWAR TEMPLE

120

Discharge (LPH) 144191

Hours of Pumping 16.00

Rate of Pumping (LPM) 2403.18

Diameter (mm) 250.00

Inside diameter (mm) 250.00

Designed Length (m) 3300.00

Water Velocity (m /s) 0.8160

Rate of Frictional Loss 0.003

Total Frictional Loss (m) 10.99

Total of static,driving,common heads 84.50

Total Head (m) 95.490

BH required (at 60% efficiency) 84.99

BHP provided 90.00

Hence Deepwell Turbine Pump of 90 HP Capable of discharging 2403.18 LPM to total


Head of 95.49 m due to all causes

J. M. S. P. L. Dharwad