The document lists well drilling tool positions including the working depth to reach the reverse circulation outlet at 3.43 meters, the working depth to close the master control system with a one way shifter at 4.68 meters, and various other working depth measurements for opening valves and sleeves along the drill string.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views1 page

ROC Tool For Dummies

The document lists well drilling tool positions including the working depth to reach the reverse circulation outlet at 3.43 meters, the working depth to close the master control system with a one way shifter at 4.68 meters, and various other working depth measurements for opening valves and sleeves along the drill string.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TOOLS POSITIONS

WD to RIH: - 1.55 m
WD to Close ROC: 0.40 m
WD to Reverse: 3.43 m
WD to Close MCS with One Way Shifter: 4.68 m
WD to Set the Isolation Plug

15 m 23 m
Flow Diversion Sleeve
Activated
Flow Path from WS to
Washpipe via WP Bypass

3m

Flow Diversion Sleeve Activated


Flow Pass from WS to Washpipe
Bypass

11 m 8m

Flow Diversion Sleeve


Activated
Flow Path from WS to
Washpipe via WP Bypass

4,68 m

Hydrostatic Maintained through


3,18 m
Annulus via Flow Diversion
Sleeve and Washpipe Bypass
Last Seal Above
Packer Bore

ROC Opened on
One Way
Positionning Nipple
0,90 m Full WP Flowpath
Hydrostatic Maintained through
Annulus via Flow Diversion
Sleeve and Washpipe Bypass

1,55 m

Packer Test By Pressuring Up the Last Seal Above Packer Bore


Annulus to 1000 Psi Weldment above
Allowing Return Flow Path
Flow Pass via Annulus to Diversion the Packer Bore
Through Annulus
Sleeve Down to Washpipe ByPass
Against the ROC Rupture Disk
Retrurn Flow to Surface Hydrostatic Maintained through ROC Still Closed
through Washpipe Bypass Annulus via Flow Diversion Needs to be Slacked Off throught Seals Engaged in Packer Bore
and Flow Diversion Sleeve Sleeve and Washpipe Bypass the One Wat Positioning Nipple to Allowing Flow Diversion
VBA PACKER

Open Sleeve Test

ONE WAY Weldment In Upper Extension


POSITIONNING NIPPLE 1,20 m Hydrostatic Maintained down Workstring ROC Closed Below the One
thru weldment and opened MCS Way Positionning Nipple
UPPER

1,19 m

Hydroplug Sheared Opening Washpipe


EXT.

Rupture Disk Sheared


By Pass
One Way MCS Closed and Isolated
Shifter Above Test @ 4,500 Psi by
MCS Pressuring Up the Tubing
CLOSING SLEEVE

WD Collet
MCS Open MCS Open MCS Open MCS Open MCS Closed MCS Closed MCS Closed MCS Closed MCS Closed
Weldment Isolated In MCS SealBore 0,91 m
Hydroplug Closed when RIH to allow
Washdown 0,98 m
ROC (Closed) Below MCS
Hydroplug Open Before Packer sets Rupture Disk Sheared
to allow Annulus Communication Hydrostatic Maintained
through Weep Tube
One Way Shifter
Below MCS

WD Collet
ROC (Closed) Above Positionning
Nipple MCS Closed
Rupture Disk Sheared
LOWER EXTENSION 1

Hydrostatic Maintained through


Workstring: Weep Rate Predetermined
through ROC Flow Tube
3,66 m

MKP One Way Shifter Above 2


Ways Positionning Nipple
2 Ways Positionning Nipple
Must Have Been Cycled Back to
Original Position with ROC

ROC (Closed) Above


0,98 m
Positionning Nipple
TWO WAY Rupture Disk Sheared
POSITIONNING NIPPLE MKP One Way Shifter @ 1500 psi
Below 2 Ways 0,40 m ROC (Open) Below
Positionning Nipple ROC (Open) Below Positionning Nipple
Positionning Nipple
1,95 m Rupture Disk Sheared
LOWER EXTENSION 2

ROC (Open) Below


2,38 m

Positionning Nipple
Rupture Disk Intact

Weight Down
Collet

WD Collet
WEIGHT DOWN on Ind WD Collet on
INDICATING NIPPLE Coupling Ind Coupling

Weight Down
LOWER EXTENSION 3

Collet
2,38 m

1 - Drop 1 ¾ Setting Ball and Set the


Packer
Hydroplug Shears @ 1,180 Psi
Packer start to set @ 1,840 Psi
Packer full set @ 2,900 Psi

2 – Release Service Tool


5 – Annulus Pressure Test to 1000 psi
3 - Pickup 2,50 m to have the ROC above ROC Close
the Two Ways Positioning Nipple 15 – Test MCS @ 4,500 Psi through WS 20 – Pressure test Annulus @ 450 Psi
MKP Shifter Cycles Positionning Nipple 6 – Shear ROC Rupture Disk to 1500 psi 12 – Reverse out ROC Open 18 – Pressure Up and Open Flow Confirm Flow Diversion Sleeve
ROC Still Open ROC Close - Rupture Disk Sheared ROC Closed – Rupture Disk Sheared Diversion Sleeve Opens
One Way Shifter Below the MCS 16 – Pick Up 11 Meters Flow Diversion Sleeve Activates @
4 - Slack off to Weight Down Position 7 – Mark Tool Position Reverse out @ 6 bpm ROC Closes Through 2 Ways Positioning 1,180 psi 21 – Pickup 10 meters 22 – Treat the Formation
ROC Cycles Positionning Nipple back to 10 – Pump Gravel Pack Until Sand Out Nipple Set Isolation Plug WITH 15 Kips
Original Configuration 8 – Pick up to Reverse Position and Pickle ROC Open 13 – Pickup to Close MCS with MKP ROC Above the One Way Positioning 19 – Circulation Test @ 2 bpm OverPull 22 – Resume Pick Up
ROC Still Open Workstring One Way Shifter 14 – Slackoff Back to WD Position Nipple Release Isolation Plug Running Tool Close FS 1
One Way Shifter Above Two Way ROC Close - Rupture Disk Sheared 11 – Apply 500 Psi on Backside and Pick Up MKP One Way Shifter Shifts Closed MKP Shifter does not Open MCS Seals Are Out of the Packer Bore 20 – Slackoff 3 meters with 30 Kips Test FS1 @ 4,500 Psi
Positionning Nipple to Reverse Position the MCS ROC Opens Through 2 Way Positioning Isolation Plug Not Set Seals Engaged in the Packer Bore
9 – Slackoff to Weight Down Position ROC Closes on 2 Ways Indicating Nipple - ROC below the MCS Nipple ROC Open Below the One Way 21 – Continue Pickup 5 meters 23 – POOH
5 - Pickup to Packer Test Position ROC Opens on Two Ways Indicating Nipple Rupture Disk Sheared ROC Closed – Rupture Disk Sheared Weight Down 40 Kips on WD Collet 17 – Drop 1.875 Ball Positionning Nipple
ROC Closed through Positionning Nipple Slackoff 40,000 kips on WD Collet

1 2 3 6 7 8 9
4 5
RUNNING / PACKER SETTING
PACKER TEST AGAINST WEIGHT DOWN REVERSE OUT CLOSE MCS W/ ONE MCS TESTING TEST ISOLATION TREAT THE FORMATION
POSITION ACTIVATE ISOLATION
ROC RUPTURE DISK POSITION ROC CLOSED WAY MKP SHIFTER WEIGHT DOWN SLEEVE AND OPEN ROC
WASHDOWN SLEEVE
FLOATING POSITION GRAVEL PACKING MCS OPEN TO CONVERT TOOL TO
WASHDOWN