Eurocode 6: Design of Masonry Structures

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

26/06/2019 Design Examples

Eurocode 6: Design of Masonry Structures


Home Concentrated Load
Design Examples 1. This example considers the design of a plain masonry
About Eurocode 6 wall carrying precast concrete floor beams. Solution
Example 1.
Disclaimer
Courses and CPD
Lateral Load
These design examples have been prepared using the best
Design Examples endeavours of the authors. They do not represent full 1. This example considers the design of a plain masonry
design solutions and the authors expressly disclaim any panel subjected to wind load. Solution Example 1.
liability with respect to their accuracy. To download the 2. This example considers the design of a masonry panel
Support Material examples amd solutions as a pdf file please click on the with bed joint reinforcement subjected to wind load.
respective link for each file. Solution Example 2.
Design Programs
Copyright Fire
About Supporting Standards These examples are copyright. They are for the private use 1. This example considers the fire resistance of single
of individuals and for teaching in Universities. Under no leaf brickwork and blockwork walls. Solution Example
circumstances may they be used in Public, In-house and 1.
Other Eurocode Links
other commercial course provision without written 2. This example extends Example 1 to cover aac
approval. blockwork laid using thin joint mortar. Solution
Other Masonry Links Example 2.
Ackowledgement 3. This example considers an internal compartment
loadbearing wall of lightweight aggregate
Frequently Asked Questions Thanks are due to the Charlwood Partnership Limited for
blockwork.Solution Example 3.
contributing to the devlopment of the design examples.
4. This example considers a brick-block cavity wall.
About This Site Vertical Load Solution Example 4.

Contact Us 1. This example covers the characteristic strength and Reinforced Masonry
load capacity of a brick wall and a block wall.
1. This example considers a reinforced retaining wall
Solution Example 1 .
Solution Example 1.
2. This example extends Example 1 to cover a Group 1
2. This example considers a reinforced masonry beam
concrete block. Solution Example 2.
Solution Example 2.
3. This example looks at an eccentric load on the
3. This example considers a reinforced masonry
lower storey of a four storey building. Solution
column.Solution Example 3.
Example 3.
4. This example considers a grouted cavity retaining wall.
4. This example looks at an internal loadbearing wall
Solution Example 4.
constructed with Group 1 and Group 2 units.
Solution Example 4.
5. This example looks at part of a four storey Back to home page.
building. Solution Example 5.
3rd January 2018
6. This example extends Example 3 to include wind
load. Solution Example 6.
7. This example considers a single storey cavity wall.
Solution example 7.

https://www.eurocode6.org/Design Examples.htm 1/1

You might also like