Load Display Fd100-Fd200 Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Nokeval www.nokeval.

com
[email protected]
Yrittäjäkatu 12
FIN 37100 Nokia
Tel.
Fax.
+358-3-342 4800
+358-3-342 2066

575F-, FD100X-, and FD200X-2012


Large field displays for process inputs
• Inputs 0/4..20 mA, 0..5/10 V and potentiometer
• Digit sizes 57, 100 and 200 mm, 4, 5 and 6 digits
• Display scaling with keys and a minidisplay
• 2 adjustable alarm limits as an option
• Alarm reset, display hold and taring by
external contact
• Analog ouput 4-20 mA/0-10V as option
• Serial RS485 output as an option
• Power supply 48..240 VAC or 24 VDC
• Case protection IP66

The large field displays have been designed for targets Analog conversion is done by a 16-bit AD-converter
where visibility is needed up to 100 metres. The displays are (resolution 1/64000) and the number of measurements is 7
suitable for the outdoor use when the vertical sunlight has per second. Separate passwords can be set for access to
been limited e.g by using the sun visor above the display. the configuration menu and alarms. Case protection rating is
IP66. The displays can also be used outdoors if exposure to
The selection of the sensor type and display scaling is direct sun light is prevented by using a sun cover.
easy with the configuration keys and a 6-digit small
display inside the case. Two alarm relays with change- Large field displays can easily be modified for other sensor
over contacts are available as an option. Alarm limits types by only changing the input card for frequency, pulse
and hysteresis are freely selectable . The display can be or serial bus inputs. All panel meter series of 2000 input and
damped by a digital filter if necessary. The number of output cards are available.
decimals is selectable.
Readability of displays: Digit size Distance
There are two power supply alternatives: one for line voltage 57 mm 20..30 m
48..240 VAC and the other 24 VDC, galvanically isolated 100 mm 40..50 m
from input and output. The field displays provide a voltage 200 mm 100 m
supply of 24 VDC for sensors.

Modular large field display 2012


Power supply
Inputs: 24 VDC, max 40 mA
for transmitter
+ + 24 VDC
Power supply:
2-wire
transmitter 85...240 VAC
4-20 mA or 24 VDC
4-20 mA

+
0/4 ..20 mA +
50 R Alarm relay 1
max 240 VAC, 2A
-
Common (-) 400.0 ºC (option)

0-5/10V +
+ Alarm relay 2
Potentiometer + 2.5V
max 240 VAC, 2A
100ohm-10kohm +
(option)
Changeable input/
output cards
Optional alarm card
has two relays
Inputs are galvanically isolated from power supply
Specifications: Models:

Model 575F- Digit size 57 mm, 5 digits, red LED


Process inputs: 0..20 mA, 4..20 mA, 0..5 V and 0..10V Dark grey plastic enclosure, IP66 (Nema 4)
Display scaling on the whole display range
Input resistance current input 50Ω, voltage input >1 MΩ Model FD100A4- Digit size 100 mm, 4 digits, red LED
Accuracy 0,05 % FS Dark gray steel enclosure, IP66
Linearity 0,01 % FS
Supply for transmitter 24 VDC, max. 40 mA Model FD100A6- Digit size 100 mm, 6 digits, red LED
Dark gray steel enclosure, IP66
Potentiometer input: 100Ω -10kΩ
Reference voltage 2,5 V, max load 25 mA
Model FD200A4- Digit size 200 mm, 4 digits, red LED
Voltage stability 150 ppm/°C
Dark gray steel enclosure, IP66
Accuracy 0,05 % FS

Alarms (optional): 2 alarms with change-over contacts, Model FD200A6- Digit size 200 mm, 6 digits, red LED
relays max 240 VAC, 2 A; hysteresis 0..100% Dark gray steel enclosure, IP66
Alarm reset:automatic or manual by
external contact or via configuration keys. x=number of digits, please specify in your order
Reversible function for relays.
How to order: FD100F4-F48/240VAC-2012 - X
General:
AD-conversion 16 bits (1/64000) Type
Input filter adjustable digital filter Number of digits
External contact: display hold, alarm reset or display taring Power supply
Configuration keys and a minidisplay inside the case 230 VAC or 24 VDC
Operating temp. -35..+50ºC Input card
Terminals removable, wire 2,5 mm² Option cards (max 2 cards)
Power supply 48..240 VAC or 24 VDC ± 15 %
Case protection: IP66 Option cards:
Weight 575F: 3 kg, FD100A4: 5 kg, FD100A6: 8 kg, Alarm card, 2 relays REL2
FD200A4: 14 kg, FD200A4: 18 kg Analog output OUT
Serial output RS485

Connections:

Current/Voltage input 2-wire transmitter Potentiometer External contact

6 6 1 6 - Display hold
5 2-johdinlähetin
5 2 5 - Alarm reset
4 + 4..20 mA -
0..5/10V 4 3 4
- - Display taring
3
0/4..20 mA
3 - 4 3
2 + - 2 5 + 2
1 + 1 + 6 1
Potentiometers:
A A Power supply 24 V A 100Ω..10kΩ
to transmitter (max. 40 mA)
Terninals

FD100A4, FD200A6
6 6 6
Rele 1
5 5 Nc 5
4 4-20 mA 4 No 4 The front cover opens on the quick locks
3 - 3 3 Glands: 2 x PG 13
2 + 2
Rele 2
Nc 2
1 1 No 1
7 8 9
A B C
123 (FD200)
105 (FD100)

Tuloviesti Optiokortti 2 Hälytykset

Power supply
25

230 VAC or 24 VDC 50 50

503, 685 (FD100A4, FD100A6) 737, 1040 (FD200A4, FD200A6)


575F5
477, 659 712, 1015
310 450, 632 687, 987
281 96
145, 260 (FD200)
190, 310 (FD200)
118

138

296

You might also like